22 results on '"Fernando Lozano, Ruíz-Poveda"'
Search Results
2. Single coronary artery presenting as acute myocardial infarction
- Author
-
Alfonso Jurado-Román, Ignacio Sánchez-Pérez, Fernando Lozano-Ruíz-Poveda, Natalia Pinilla-Echeverri, María T. López-Lluva, Andrea Moreno-Arciniegas, Manuel Marina-Breysse, and Jesús Piqueras-Flores
- Subjects
Diseases of the circulatory (Cardiovascular) system ,RC666-701 - Abstract
A single coronary artery is one of the most rarely seen coronary artery anomalies. In addition, the specific subtype (Lipton RII-A) that our patient presented is one of the least common, and its clinical presentation as myocardial infarction and cardiac arrest has not been described in the literature. The case shows that although it is essential to exclude a malignant interarterial course of the vessel, cardiac arrest is a possible clinical presentation produced by myocardial ischemia in the context of acute myocardial infarction and should be managed according to clinical practice guidelines. Resumo: Uma artéria coronária única é uma das anomalias mais raras das artérias coronárias. Além disso, o subtipo específico (Lipton R-IIA) presente no nosso doente é um dos menos frequentes e a sua apresentação clínica como enfarte do miocárdio e como paragem cardíaca não foi ainda descrita na literatura. O caso mostra que, embora o descarte de um percurso interarterial maligno do vaso seja essencial, a paragem cardíaca é uma apresentação clínica possível causada por isquemia do miocárdio no cenário de um enfarte agudo do miocárdio, que deverá ser tratada de acordo com as recomendações práticas clínicas. Keywords: Single coronary artery, Myocardial infarction, Cardiac arrest, Multislice computed tomography, Palavras chave: Artéria coronária única, Enfarte do miocárdio, Paragem cardíaca, Tomografia computorizada multislice
- Published
- 2017
- Full Text
- View/download PDF
3. Percutaneous Intervention in Diffuse Coronary Disease: Overlapping Versus Single Very Long Stent Technique. Results From the OVERLONG Registry
- Author
-
Fernando Lozano-Ruíz-Poveda, Ignacio Sanchez-Perez, José Abellán-Huerta, Alfonso Jurado-Román, María T. López-Lluva, Javier González López, Martín Negreira-Caamaño, and Pedro Pérez-Díaz
- Subjects
Male ,medicine.medical_specialty ,Time Factors ,Percutaneous ,medicine.medical_treatment ,Coronary Artery Disease ,030204 cardiovascular system & hematology ,Coronary disease ,Coronary artery disease ,03 medical and health sciences ,Percutaneous Coronary Intervention ,0302 clinical medicine ,Recurrence ,Internal medicine ,Intervention (counseling) ,medicine ,Humans ,Registries ,030212 general & internal medicine ,Non-ST Elevated Myocardial Infarction ,Aged ,Retrospective Studies ,business.industry ,Percutaneous coronary intervention ,Stent ,Middle Aged ,medicine.disease ,Treatment Outcome ,Cardiology ,ST Elevation Myocardial Infarction ,Female ,Stents ,Cardiology and Cardiovascular Medicine ,business - Abstract
Background Both stent length and stent overlap are associated with worse outcomes in the percutaneous treatment of diffuse coronary artery disease (dCAD). However, evidence comparing these issues is scarce. We aimed to compare the results between the use of single very long stent (VLS) and ≥2 overlapping stents (OS) in the treatment of dCAD. Methods Seven hundred twenty-four consecutive lesions were included: 275 treated with a single VLS (≥40 mm) and 449 with ≥2 OS. Procedural characteristics were assessed, and survival analysis was performed to compare the incidence of major adverse cardiovascular events (MACE; composite of cardiovascular death, nonfatal myocardial infarction, target lesion revascularization [TLR], or stent thrombosis) during a median follow-up of 31 months. Results Procedures with VLS required less contrast volume (268 ± 122 vs 302 ± 113 cm3; P < .01), fluoroscopy time (16 ± 8 vs 21 ± 16 minutes; P < .01), and procedure duration (37 ± 18 vs 47 ± 27 minutes; P < .01) than the OS procedures. The VLS group showed lower incidence of MACE (4.4% vs 10.7%; P < .01), driven mainly by lower TLR rate (1.1% vs 4.7%; P < .01). The use of OS was an independent predictor of MACE. Conclusions In this study, the use of VLS for the treatment of dCAD was associated with better outcomes compared to OS.
- Published
- 2021
- Full Text
- View/download PDF
4. Bioactive or Drug-Eluting Stents in 75 Years or Older Patients: The BIODES-75 Registry
- Author
-
Juan G. Córdoba-Soriano, Antonio Gutiérrez-Díez, Bruno García Del Blanco, Julio Núñez, Ignacio J. Amat-Santos, Juan Francisco Oteo, Rafael Romaguera, Arsenio Gallardo-López, Fernando Lozano Ruíz-Poveda, Pascual Baello, Pablo Aguar, Miguel Jerez-Valero, Víctor Alfonso Jiménez-Díaz, Bernat Serra, Jose Domingo Cascon, Francisco J. Morales-Ponce, Juan José Portero-Portaz, Driss Melehi El Assali, Pablo Cerrato-García, and Jesús Jiménez-Mazuecos
- Subjects
Percutaneous Coronary Intervention ,Time Factors ,Treatment Outcome ,Myocardial Infarction ,Humans ,Drug-Eluting Stents ,Stents ,General Medicine ,Prospective Studies ,Registries ,Cardiology and Cardiovascular Medicine ,Aged ,Retrospective Studies - Abstract
TiNO-coated BAS have demonstrated competitive outcomes compared to drug-eluting stents (DES). These devices allow short antiplatelet regimens and may be a good option for the growing elderly population undergoing percutaneous coronary intervention (PCI).Multicenter observational trial in routine clinical practice. A propensity-score matched analysis compared a prospective cohort of patients ≥ 75 years undergoing PCI with BAS, with a contemporary and retrospective cohort treated with last-generation DES. The co-primary endpoints of the study were the Target-Lesion-Failure (Cardiac death, non-fatal myocardial infarction, or target lesion revascularization) and Major Adverse Cardiovascular Events (total death, non-fatal myocardial infarction, stroke, or new revascularization) at 1 year.Whole population included 1000 patients, and 326 patients in each group were matched for analysis. No differences in primary endpoints were found: TLF 10.4% vs. 11% (HR 0.96 (Confidence Interval 95%, 0.36-1.7; p = 0.87)) and MACE 16.3% vs. 17.2% (HR 0.98 (Confidence Interval 95%; 0.3-1.5, p = 0.93)). Patients treated with BAS received shorter antiplatelets regimens (dual antiplatelet therapy at 1 year, 25.7% vs. 70.6%, p = 0.0001), and they presented lower incidence of bleeding (3.7% vs. 11.7%, HR 0.3 (IC 95% 0.16-0.6, p = 0.001)).In this real-life registry of patients ≥ 75 years, BAS were similar to the latest-generation DES in terms of efficacy and reduced the duration of the antithrombotic therapy, lowering bleeding events.
- Published
- 2022
5. Acute Myocardial Infarction Caused by Shotgun Pellet: OCT Insights
- Author
-
Ariana, Gonzálvez-García, Ignacio, Sánchez-Pérez, Fernando Lozano, Ruíz-Poveda, Santiago, Jiménez-Valero, Francisco Javier, Ruíz-Lorenzo, Carlos, Pastor-Sánchez, and Alfonso, Freites-Esteves
- Subjects
Percutaneous Coronary Intervention ,Treatment Outcome ,Myocardial Infarction ,Humans ,Coronary Angiography ,Coronary Vessels ,Tomography, Optical Coherence - Published
- 2021
6. Comparison of Clinical Outcomes Between Very Long Stents and Overlapping Stents for the Treatment of Diffuse Coronary Disease in Real Clinical Practice
- Author
-
Fernando Lozano-Ruíz-Poveda, José Abellán-Huerta, María T. López-Lluva, Alfonso Jurado-Román, Ignacio Sanchez-Perez, Jesús Piqueras-Flores, Raquel Frías-García, Pedro Pérez-Díaz, Ramón Maseda-Uriza, and Juan Antonio Requena
- Subjects
Male ,medicine.medical_specialty ,Time Factors ,Percutaneous ,medicine.medical_treatment ,Myocardial Infarction ,Coronary Artery Disease ,030204 cardiovascular system & hematology ,Coronary disease ,Prosthesis Design ,03 medical and health sciences ,Percutaneous Coronary Intervention ,0302 clinical medicine ,Risk Factors ,Humans ,Medicine ,Fluoroscopy ,Registries ,cardiovascular diseases ,030212 general & internal medicine ,Myocardial infarction ,Adverse effect ,Aged ,Retrospective Studies ,Index Lesion ,medicine.diagnostic_test ,business.industry ,Coronary Thrombosis ,Stent ,General Medicine ,Middle Aged ,equipment and supplies ,medicine.disease ,Clinical Practice ,Treatment Outcome ,surgical procedures, operative ,Retreatment ,Female ,Stents ,Radiology ,Cardiology and Cardiovascular Medicine ,business - Abstract
BACKGROUND The stent length as well as the stent overlap for the percutaneous treatment of diffuse coronary disease have been considered predictors of adverse events. However, there are no comparative data on the use of very long stents or overlapping stents in this scenario. OBJECTIVE To compare the clinical results of very long stents (≥40 mm) or overlapping stents in real clinical practice. METHODS We included 643 lesions in 628 consecutive patients treated with a single very long stent (≥40 mm) (251 lesions) or ≥2 overlapped stents (392 lesions). We analyzed the procedural characteristics and the presentation of the combined endpoint [cardiovascular death, non-fatal myocardial infarction, need for target lesion revascularization or stent thrombosis] after a follow-up of 20 months. RESULTS Total stent length was 54 ± 18 mm and minimum diameter was 2.9 ± 1.2 mm. At the end of follow-up, the rate of adverse events was 8.3% (cardiac death: 4.9%, myocardial infarction: 1.7%, target lesion revascularization: 3.1%, stent thrombosis: 0.7%). There were no significant differences between both groups in the presentation of the combined endpoint. Procedures with overlapping stents had more contrast volume (309 ± 115 vs 273 ± 127 ml; p = 0.002), longer duration (47 ± 22 vs 39 ± 18 min; p
- Published
- 2019
- Full Text
- View/download PDF
7. Left main coronary artery percutaneous revascularization: alea jacta est
- Author
-
Fernando Lozano Ruíz-Poveda, and José Abellán-Huerta, and Ignacio Sanchez-Perez
- Subjects
medicine.medical_specialty ,medicine.anatomical_structure ,Percutaneous ,business.industry ,Internal medicine ,medicine.medical_treatment ,medicine ,Cardiology ,Cardiology and Cardiovascular Medicine ,Revascularization ,business ,Artery - Published
- 2021
- Full Text
- View/download PDF
8. Long-Term Follow-Up of Percutaneous Coronary Intervention With Paclitaxel-Eluting Balloon Catheter
- Author
-
José Abellán-Huerta, Fernando Lozano-Ruíz-Poveda, Natalia Pinilla-Echeverri, Alfonso Jurado-Román, Ignacio Sanchez-Perez, Pedro Pérez-Díaz, Jesús Piqueras-Flores, and María T. López-Lluva
- Subjects
Bare-metal stent ,Male ,medicine.medical_specialty ,Percutaneous ,Time Factors ,Paclitaxel ,medicine.medical_treatment ,Coronary Artery Disease ,030204 cardiovascular system & hematology ,Balloon ,Cardiac Catheters ,Coronary Restenosis ,03 medical and health sciences ,0302 clinical medicine ,Restenosis ,Coated Materials, Biocompatible ,Internal medicine ,Medicine ,Humans ,cardiovascular diseases ,030212 general & internal medicine ,Prospective Studies ,Acute Coronary Syndrome ,Angioplasty, Balloon, Coronary ,Aged ,business.industry ,Stent ,Percutaneous coronary intervention ,Cardiovascular Agents ,Equipment Design ,Middle Aged ,medicine.disease ,Treatment Outcome ,Conventional PCI ,Cardiology ,Female ,Cardiology and Cardiovascular Medicine ,business ,Mace - Abstract
Drug-eluting balloons currently constitute a therapeutic tool used in percutaneous coronary interventions (PCI). Long-term results remain unknown. We evaluated the prognosis of PCI using a second generation paclitaxel-eluting balloon (PEB) in real-world patients. We included all PCI with PEB in de novo or in-stent restenosis coronary lesions performed in our unit from March 2009 to March 2019. We assessed the composite of major adverse cardiovascular events (MACE) rate after a median follow-up of 42 months. Consecutive patients (n = 320) with 386 lesions were included; 46.9% presented with stable angina and 53.1% acute coronary syndromes; 52.6% of the lesions were in-stent restenosis and 47.3% de novo lesions with a mean diameter of 2.4 ± 0.5 mm. A bare metal stent was implanted in 6.7% and a drug-eluting stent in 8.5% of patients. The MACE rate was 8%: 10 (2.6%) cardiovascular deaths, 13 (3.4%) myocardial infarctions, and 16 (4.1%) target lesion revascularization. The all-cause death rate was 5.2%. No cases of thrombosis were recorded. In conclusion, PEB was a safe and effective tool to treat in-stent restenosis and de novo coronary lesions, especially small vessel disease, during long-term follow-up.
- Published
- 2020
9. Clinical Prognosis Associated With the Use of Overlapping Stents With Homogenous Versus Heterogeneous Pharmacological Characteristics for the Treatment of Diffuse Coronary Artery Disease
- Author
-
María T. López-Lluva, José Abellán-Huerta, Pedro Pérez-Díaz, Fernando Lozano-Ruíz-Poveda, Martín Negreira-Caamaño, Juan A. Requena-Ibañez, Ignacio Sanchez-Perez, and Alfonso Jurado-Román
- Subjects
Male ,medicine.medical_specialty ,medicine.medical_treatment ,Coronary Artery Disease ,Kaplan-Meier Estimate ,030204 cardiovascular system & hematology ,Coronary artery disease ,03 medical and health sciences ,Clinical prognosis ,0302 clinical medicine ,Percutaneous Coronary Intervention ,Risk Factors ,medicine ,Clinical endpoint ,Humans ,030212 general & internal medicine ,Aged ,business.industry ,Percutaneous coronary intervention ,Stent ,Drug-Eluting Stents ,General Medicine ,Middle Aged ,medicine.disease ,Prognosis ,Treatment Outcome ,Homogeneous ,Drug-eluting stent ,Conventional PCI ,Female ,Radiology ,Cardiology and Cardiovascular Medicine ,business - Abstract
The clinical impact of percutaneous coronary intervention (PCI) and implantation of overlapping stents (OS) using platforms with the same versus different pharmacological characteristics is unknown. Our objective was to compare the outcomes of PCI with OS according to their pharmacological characteristics.In this observational single-center registry, we included all PCI performed from April 2014 to December 2018 in which overlapping drug-eluting stents were implanted. Two groups were created according to whether the stents release the same drug [homogeneous: (HO)] or different [heterogeneous: (HE)]. The primary endpoint was the need for target lesion revascularization (TLR). Clinical assessment was performed after the procedure, bianually and at the end of follow-up (June 2019).381 lesions with OS (HO: 209; HE: 172) were included (75.1% male, 66.7 ± 11.6 years). Clinical presentation was stable coronary artery disease in 49.9%. Syntax score was 23.7 ± 13.3. The number of OS implanted was 2.2 ± 0.5 and the total stent length was 59.5 ± 20.1 mm (HE: 61.5 ± 21.6 vs. HO: 57.8 ± 18.8 mm; p 0.01). After a median follow-up of 21 months, the HE group showed a lower TLR rate than the HO group (HE:2.3% vs HO:7.2%; p = 0.03). The rates of cardiac death (p = 0.44), myocardial infarction (p = 0.36) and stent thrombosis (p = 0.85) were similar between groups. In the multivariate analysis, the OS with homogeneous-drug devices was an independent predictor of a higher rate of TLR.PCI using OS with homogeneous pharmacological characteristics was associated with a higher rate of TLR in comparison with the implantation of OS with heterogeneous pharmacological characteristics.
- Published
- 2020
10. An Unusual Entity: Woven Coronary Artery Anomaly
- Author
-
María T, López-Lluva, José, Abellán-Huerta, Ignacio, Sánchez-Pérez, Pedro, Pérez Díaz, and Fernando, Lozano Ruíz-Poveda
- Subjects
Diagnosis, Differential ,Coronary Vessel Anomalies ,Humans ,Female ,Coronary Artery Disease ,Middle Aged ,Coronary Angiography ,Tomography, Optical Coherence - Abstract
The recognition of woven coronary artery anomaly is difficult because of its rare nature. Optical coherence tomography imaging is challenging due to the tortuosity of the channels; however, it is crucial not only for the differential diagnosis but also to guide the treatment approach.
- Published
- 2020
11. Systematic isolated post-dilatation of the side branch as part of the provisional stent technique in the percutaneous treatment of coronary bifurcations. CR12 Registry
- Author
-
Felipe Hernández-Hernández, Belén Rubio-Alonso, Julio García-Tejada, Ignacio Sanchez-Perez, Alfonso Jurado-Román, María T. López-Lluva, María Teresa Velázquez-Martín, Fernando Lozano-Ruíz-Poveda, Iván Gómez-Blázquez, and Agustín Albarrán-González-Trevilla
- Subjects
Male ,medicine.medical_specialty ,Time Factors ,Percutaneous ,medicine.medical_treatment ,Coronary Artery Disease ,030204 cardiovascular system & hematology ,Cardiac mortality ,Coronary Angiography ,Radiography, Interventional ,03 medical and health sciences ,0302 clinical medicine ,Risk Factors ,Side branch ,Internal medicine ,medicine ,Humans ,Prospective Studies ,Registries ,030212 general & internal medicine ,Myocardial infarction ,Stent thrombosis ,Angioplasty, Balloon, Coronary ,Target lesion revascularization ,Aged ,business.industry ,Coronary Thrombosis ,Stent ,General Medicine ,Middle Aged ,medicine.disease ,Surgery ,Treatment Outcome ,medicine.anatomical_structure ,Spain ,Cardiology ,Female ,Stents ,Cardiology and Cardiovascular Medicine ,business ,Artery - Abstract
Aims To analyse systematic isolated post-dilatation of the side branch as a part of provisional stent technique. Methods 1960 angioplasties performed in two centres were prospectively registered, of which 382 were coronary bifurcations with a side branch > 2 mm. In centre A, isolated post-dilatation of the side branch was performed regardless its impairment after main vessel stenting. In centre B, side branch post-dilatation was performed only if it was severely affected after stent implantation. Results There was no difference between the two centres in the rate of side branch affection after stent implantation (A: 44.6 vs B: 49.3%, p = 0.48) nor in the procedural success rate (A: 98.6% vs B: 96.7%, p = 0.45). After one-year follow-up, a reduction of cardiovascular events was observed in centre A (A: 4.4% vs B: 10.4%, p = 0.043) with a trend towards lower cardiac mortality (A: 2.2% vs B: 6.5%, p = 0.093) and stent thrombosis (A: 0% vs B: 2.6%, p = 0.077). There were no differences in the rate of myocardial infarction related to the treated artery (A: 1.4% vs B: 3.9%, p = 0.29), or target lesion revascularization (A: 1.4% vs. B: 3.2%, p = 0.45). Conclusions Systematic isolated post-dilatation of the side branch in the provisional stent technique was associated with a high angiographic success rate, and a low rate of cardiovascular events during follow-up. Although the study design does not allow definitive conclusions, this strategy could be considered a valid option in some cases or even as part of the provisional stent technique.
- Published
- 2018
- Full Text
- View/download PDF
12. Refractory no-reflow phenomenon. Keep calm and watchful waiting!
- Author
-
Alfonso Jurado-Román, Jesús Piqueras-Flores, Fernando Lozano Ruíz-Poveda, María T. López-Lluva, Ignacio Sanchez-Perez, José Abellán-Huerta, and Ramón Maseda-Uriza
- Subjects
Risk awareness ,medicine.medical_specialty ,business.industry ,medicine.medical_treatment ,Cardiovascular risk factors ,medicine.disease ,Refractory ,Thrombus burden ,No reflow phenomenon ,cardiovascular system ,medicine ,Abciximab ,In patient ,cardiovascular diseases ,Intensive care medicine ,business ,Watchful waiting ,medicine.drug - Abstract
Risk awareness of no-reflow is mandatory, especially in patients with cardiovascular risk factors, long door-to-balloon time, and in the presence of angiographic evidence of a large thrombus burden. Some preventive strategies have been described. Nevertheless, in clinical practice, is difficult to avoid no-reflow. Interventional cardiologists have no guidelines or recommendations for this situation. We suggest that a conservative management with dual antiplatelet therapy and slow intravenous infusion of nitroglycerine over 12 to 24 hours and abciximab, followed by deferred [...]
- Published
- 2019
- Full Text
- View/download PDF
13. Insuficiencia tricuspídea funcional y miocardiopatía hipertrófica apical. Estrategia diagnóstica y terapéutica a propósito de un caso clínico
- Author
-
Pedro Pérez-Díaz, Alfonso Jurado-Román, Ignacio Sanchez-Perez, M. Ángeles Pérez-Martínez, Juan A. Requena-Ibañez, Raquel Frías-García, Ramón Maseda-Uriza, Fernando Lozano-Ruíz-Poveda, Jesús Piqueras-Flores, Germán Hernández-Herra, and María T. López-Lluva
- Subjects
Gynecology ,medicine.medical_specialty ,business.industry ,Cardiomyopathy ,medicine ,Cardiology and Cardiovascular Medicine ,medicine.disease ,business - Published
- 2018
- Full Text
- View/download PDF
14. Reconstruction of Right Coronary Artery With 2 Giant Aneurysms in Series Using 3 Overlapped Covered Stents
- Author
-
María T. López-Lluva, Fernando Lozano-Ruíz-Poveda, Ignacio Sanchez-Perez, and Alfonso Jurado-Román
- Subjects
Male ,Coronary angiography ,medicine.medical_specialty ,medicine.medical_treatment ,030204 cardiovascular system & hematology ,Coronary Angiography ,Prosthesis Design ,03 medical and health sciences ,0302 clinical medicine ,Coronary Aneurysms ,medicine.artery ,Internal medicine ,Fibrinolysis ,medicine ,Humans ,cardiovascular diseases ,030212 general & internal medicine ,Angioplasty, Balloon, Coronary ,Ultrasonography, Interventional ,Covered stent ,business.industry ,Inferior Myocardial Infarction ,Coronary Aneurysm ,Coronary artery lesion ,Middle Aged ,Treatment Outcome ,Thrombus burden ,Right coronary artery ,cardiovascular system ,Cardiology ,Stents ,Radiology ,Cardiology and Cardiovascular Medicine ,business ,Platelet Aggregation Inhibitors ,Tomography, Optical Coherence - Abstract
A 50-year-old man with an inferior myocardial infarction was admitted after successful fibrinolysis. Coronary angiography showed 2 giant coronary aneurysms in series in the right coronary artery with high thrombus burden ([Figure 1A][1], [Online Video 1][2]), a severe ostial lesion, and ecstatic
- Published
- 2017
- Full Text
- View/download PDF
15. Coronary Artery Tenting After Bypass Grafting: A Key Issue During Percutaneous Coronary Intervention of a Chronic Total Occlusion
- Author
-
Alfonso, Jurado-Román, José Ramón, Rumoroso, José, Abellán-Huerta, María T, López-Lluva, Ignacio, Sánchez-Pérez, and Fernando Lozano, Ruíz-Poveda
- Subjects
Male ,Cardiac Catheterization ,Graft Occlusion, Vascular ,Drug-Eluting Stents ,Coronary Angiography ,Risk Assessment ,Severity of Illness Index ,Angina Pectoris ,Treatment Outcome ,Coronary Occlusion ,Humans ,Saphenous Vein ,Angioplasty, Balloon, Coronary ,Coronary Artery Bypass ,Aged ,Follow-Up Studies - Abstract
This image series shows how bypass grafts may tent the vessel to which they are anastomosed, potentially changing the expected course of the native coronary vessel. This fact must be taken into account during CTO-PCI, and this case emphasizes the importance of careful analysis of coronary anatomy with several angiographic projections.
- Published
- 2019
16. Shockwave
- Author
-
Ignacio Sanchez-Perez, José Abellán-Huerta, Fernando Lozano Ruíz-Poveda, María T. López-Lluva, and Alfonso Jurado-Román
- Subjects
medicine.medical_specialty ,Critical stenosis ,business.industry ,medicine.medical_treatment ,Percutaneous coronary intervention ,Dissection (medical) ,030204 cardiovascular system & hematology ,Anterior Descending Coronary Artery ,Balloon ,medicine.disease ,03 medical and health sciences ,0302 clinical medicine ,Internal medicine ,medicine ,Cardiology ,030212 general & internal medicine ,Cardiology and Cardiovascular Medicine ,business - Abstract
A 73-year-old woman with a severely calcified critical stenosis in the midleft anterior descending coronary artery ([Figure 1A][1]) was referred for percutaneous coronary intervention. Pre-dilatation with a 2.5-mm noncompliant balloon at 20 atm pressure did not achieve adequate balloon expansion
- Published
- 2019
- Full Text
- View/download PDF
17. Acute pulmonary edema secondary to a hidden hypertensive emergency
- Author
-
Antonio Pinardo-Zabala, Alfonso Jurado-Román, Fernando Lozano-Ruíz-Poveda, María T. López-Lluva, Ignacio Sanchez-Perez, and Jesús Piqueras-Flores
- Subjects
medicine.medical_specialty ,business.industry ,Acute pulmonary edema ,030204 cardiovascular system & hematology ,medicine.disease ,Article ,body regions ,03 medical and health sciences ,Stenosis ,0302 clinical medicine ,Blood pressure ,Internal medicine ,Heart failure ,medicine.artery ,cardiovascular system ,medicine ,Cardiology ,Hypertensive emergency ,cardiovascular diseases ,030212 general & internal medicine ,Brachial artery ,Cardiology and Cardiovascular Medicine ,business ,Subclavian steal syndrome ,Subclavian artery - Abstract
Severe stenosis of the subclavian artery is a rare clinical finding, even more so for bilateral existence of the condition. Subclavian artery stenosis leads to erroneously normal or even low blood pressure values when measured at the brachial artery on the ipsilateral side. The poor control of blood pressure may cause cardiovascular complications such as heart failure and acute pulmonary edema without the patient having high blood pressure in the arms. Widespread clinical reliance on a sole brachial measurement of blood pressure, particularly in the emergency room setting, may result in inappropriate clinical management in patients with conditions that alter brachial blood pressure. We report a case of acute diastolic heart failure secondary to hypertensive emergency hidden due to bilateral stenosis of both subclavian arteries in a patient with severe atherosclerosis, cerebrovascular disease, and symptoms of subclavian steal syndrome.
- Published
- 2016
- Full Text
- View/download PDF
18. Coronary Artery Aneurysm After Mini-Crush Drug-Eluting Stent Technique in a Chronic Total Occlusion
- Author
-
Alfonso, Jurado-Román, María T, López-Lluva, Ignacio, Sánchez-Pérez, and Fernando Lozano, Ruíz-Poveda
- Subjects
Male ,Percutaneous Coronary Intervention ,Coronary Occlusion ,Chronic Disease ,Coronary Aneurysm ,Humans ,Drug-Eluting Stents ,Middle Aged ,Coronary Angiography ,Coronary Vessels ,Tomography, Optical Coherence ,Prosthesis Failure - Abstract
A 53-year-old man underwent percutaneous coronary intervention of a chronic total occlusion of the circumflex artery. A mini-crush stent technique with two drug-eluting stents was performed. To the best of our knowledge, this is the first case of coronary artery aneurysm affecting a bifurcated chronic total occlusion treated with a two-stent technique.
- Published
- 2017
19. Letter by Jurado-Román et al Regarding Article, 'Thrombus Aspiration in ST-Segment–Elevation Myocardial Infarction: An Individual Patient Meta-Analysis: Thrombectomy Trialists Collaboration'
- Author
-
Fernando Lozano-Ruíz-Poveda, Ignacio Sanchez-Perez, and Alfonso Jurado-Román
- Subjects
medicine.medical_specialty ,business.industry ,medicine.medical_treatment ,Percutaneous coronary intervention ,Context (language use) ,030204 cardiovascular system & hematology ,medicine.disease ,Thrombosis ,law.invention ,Surgery ,03 medical and health sciences ,0302 clinical medicine ,Randomized controlled trial ,law ,Physiology (medical) ,Meta-analysis ,Conventional PCI ,medicine ,ST segment ,cardiovascular diseases ,030212 general & internal medicine ,Myocardial infarction ,Cardiology and Cardiovascular Medicine ,business - Abstract
We have carefully read the article by Jolly et al.1 We congratulate the authors for the effort of pooling individual data from the most important trials regarding thrombus aspiration (TA). It confirms that routine TA should not be performed in this context. However, we would like to make some considerations. We agree that after the TAPAS trial (Thrombus Aspiration During Primary Percutaneous Coronary Intervention),2 TA became part of routine practice, and was probably overused. However, results of the TASTE (Thrombus Aspiration During ST-Segment Elevation Myocardial Infarction)3 and TOTAL (Randomized Trial of Primary PCI With or Without Routine Manual Thrombectomy)4 trials, which drive the bulk of the overall effect …
- Published
- 2017
- Full Text
- View/download PDF
20. Bioresorbable vascular scaffold to treat malignant in-stent restenosis in a patient with nickel allergy
- Author
-
Alfonso Jurado-Román, Ramon Maseda, Fernando Lozano-Ruíz-Poveda, María T. López-Lluva, Jesús Piqueras-Flores, and Ignacio Sanchez-Perez
- Subjects
Nickel allergy ,medicine.medical_specialty ,medicine.medical_treatment ,030204 cardiovascular system & hematology ,Coronary Angiography ,Coronary Restenosis ,03 medical and health sciences ,0302 clinical medicine ,Percutaneous Coronary Intervention ,Restenosis ,Nickel ,Absorbable Implants ,medicine ,Hypersensitivity ,Humans ,Medical history ,030212 general & internal medicine ,Allergic contact dermatitis ,Bioresorbable vascular scaffold ,business.industry ,Percutaneous coronary intervention ,Drug-Eluting Stents ,General Medicine ,Middle Aged ,equipment and supplies ,medicine.disease ,Surgery ,Treatment Outcome ,Female ,Stents ,In stent restenosis ,Cardiology and Cardiovascular Medicine ,business ,Contact dermatitis - Abstract
Nickel is the most frequent allergen in patients with allergic contact dermatitis and nickel allergy has been associated with recurrent in-stent restenosis. However, it is often misdiagnosed because of a low suspicion threshold. It should be discarded in patients with recurrent in-stent restenosis, especially if their medical history reveals prior contact dermatitis. It is also noteworthy and rarely specified that even newer generation stents that use novel metal alloys also contain low amounts of nickel. To avoid the implantation of new stents containing this metal, when percutaneous coronary intervention is indicated, drug eluting balloons or bioresorbable vascular scaffolds associated with small doses of steroids could provide good alternatives of treatment. To the best of our knowledge, this is the first description of this therapeutic alternative in such an exceedingly rare clinical scenario.
- Published
- 2016
21. Transcatheter aortic valve implantation: the importance of an experienced multidisciplinary team
- Author
-
Fernando Lozano-Ruíz-Poveda, María T. López-Lluva, Jesús Piqueras-Flores, Alfonso Jurado-Román, Verónica Hernández-Jiménez, Ignacio Sanchez-Perez, Natalia Pinilla-Echeverri, Javier Jiménez-Díaz, and Manuel Marina-Breysse
- Subjects
Aged, 80 and over ,medicine.medical_specialty ,Transcatheter aortic ,Medical Errors ,business.industry ,General surgery ,Aortic Valve Stenosis ,Multidisciplinary team ,Transcatheter Aortic Valve Replacement ,Fatal Outcome ,Postoperative Complications ,Internal medicine ,medicine ,Cardiology ,Humans ,Female ,Cardiology and Cardiovascular Medicine ,business ,Atrioventricular Block - Published
- 2016
22. Effectiveness of the implementation of a simple radiation reduction protocol in the catheterization laboratory
- Author
-
Andrea Moreno Arciniegas, Fernando Lozano Ruíz-Poveda, María T. López-Lluva, Natalia Pinilla-Echeverri, Ignacio Sanchez-Perez, Alfonso Jurado-Román, Antonio Gil Agudo, and Pilar Agudo-Quilez
- Subjects
Male ,medicine.medical_specialty ,Cardiac Catheterization ,Operating Rooms ,Time Factors ,Heart Diseases ,030204 cardiovascular system & hematology ,Coronary Angiography ,Radiation Dosage ,Radiography, Interventional ,Aortography ,030218 nuclear medicine & medical imaging ,Reduction (complexity) ,03 medical and health sciences ,0302 clinical medicine ,Percutaneous Coronary Intervention ,Predictive Value of Tests ,Occupational Exposure ,medicine ,Fluoroscopy ,Humans ,Prospective Studies ,Radionuclide Ventriculography ,Occupational Health ,Aged ,Protocol (science) ,Aged, 80 and over ,medicine.diagnostic_test ,Interventional cardiology ,SIMPLE (military communications protocol) ,business.industry ,General Medicine ,Middle Aged ,Radiation Exposure ,Dose area product ,Conventional PCI ,Cineangiography ,Radiographic Image Interpretation, Computer-Assisted ,Female ,Aortographies ,Radiology ,Patient Safety ,Cardiology and Cardiovascular Medicine ,Nuclear medicine ,business ,Hospitals, High-Volume ,Software ,Program Evaluation - Abstract
A reduction in radiation doses at the catheterization laboratory, maintaining the quality of procedures is essential. Our objective was to analyze the results of a simple radiation reduction protocol at a high-volume interventional cardiology unit.We analyzed 1160 consecutive procedures: 580 performed before the implementation of the protocol and 580 after it. The protocol consisted in: the reduction of the number of ventriculographies and aortographies, the optimization of the collimation and the geometry of the X ray tube-patient-receptor, the use of low dose-rate fluoroscopy and the reduction of the number of cine sequences using the software "last fluoroscopy hold".There were no significant differences in clinical baseline features or in the procedural characteristics with the exception of a higher percentage of radial approach (30.7% vs 69.6%; p0.001) and of percutaneous coronary interventions of chronic total occlusions after the implementation of the protocol (2.1% vs 6.7%; p=0,001). Angiographic success was similar during both periods (98.3% vs 99.2%; p=0.2). There were no significant differences between both periods regarding the overall duration of the procedures (26.9 vs 29.6min; p=0.14), or the fluoroscopy time (13.3 vs 13.2min; p=0.8). We observed a reduction in the percentage of procedures with ventriculography (80.9% vs 7.1%; p0.0001) or aortography (15.4% vs 4.4%; p0.0001), the cine runs (21.8 vs 6.9; p0.0001) and the dose-area product (165 vs 71 Gyxcm(2); p0.0001).With the implementation of a simple radiation reduction protocol, a 57% reduction of dose-area product was observed without a reduction in the quality or the complexity of procedures.
- Published
- 2016
Catalog
Discovery Service for Jio Institute Digital Library
For full access to our library's resources, please sign in.