1. Comparison of the Kron technique and digital manometry for measuring intra-abdominal pressure in emergency department patients diagnosed with ileus.
- Author
-
Unutmaz, Merve, Yıldırım, Çağdaş, Unutmaz, Mehmet Emin, Günaydın, Gül Pamukçu, Şener, Alp, and Gökhan, Şervan
- Subjects
DIGITAL technology ,MANOMETERS ,T-test (Statistics) ,DATA analysis ,COMPUTED tomography ,HOSPITAL emergency services ,DESCRIPTIVE statistics ,LONGITUDINAL method ,INTRA-abdominal pressure ,STATISTICS ,PATIENT monitoring ,DATA analysis software ,BOWEL obstructions - Abstract
BACKGROUND: Numerous measurement techniques for intra-abdominal pressure have been explored, with the Kron Technique established as the gold standard. Despite its prominence, the search for alternative methods persists due to its lengthy application time, the requirement for additional equipment, and overall impracticality. This study investigated a quicker, more accessible method for effective intra-abdominal pressure measurement in the emergency department. It aimed to compare intra-abdominal pressure measurements in patients diagnosed with ileus using a digital manometer and the Kron Technique. METHODS: Conducted from October 2022 to February 2023, this single-center, prospective, single-blind method comparison study involved patients diagnosed with ileus at a tertiary emergency department. Intra-abdominal pressure was measured using both the Kron Technique and a digital manometer by separate practitioners blinded to the study results. RESULTS: The study included 30 patients. No statistically significant difference was observed in the intra-abdominal pressure measurements between the two methods (p<0.237). A very strong correlation existed between the two methods (Spearman’s Rho = 0.998). Bland-Altman analysis showed a bias value of 0.091 mmHg for the digital manometer, with upper and lower agreement limits of -0.825 and 1.007 mmHg, respectively. The measurement time was significantly shorter with the digital manometer than with the Kron Technique (15 vs. 390.5 seconds; p<0.001). CONCLUSION: We believe that the intra-abdominal pressure measurement technique using a digital manometer is a method that can be effectively employed by healthcare professionals in emergency departments. This technique offers ease of use, requires minimal equipment, provides rapid results, and delivers reliable measurement values compared to the Kron Technique. [ABSTRACT FROM AUTHOR]
- Published
- 2024
- Full Text
- View/download PDF