25 results on '"Gabriela Hilfiker"'
Search Results
2. Very High-Power Ablation for Contiguous Pulmonary Vein Isolation
- Author
-
Louisa O’Neill, Milad El Haddad, Benjamin Berte, Richard Kobza, Gabriela Hilfiker, Daniel Scherr, Martin Manninger, Adrianus P. Wijnmaalen, Serge A. Trines, Jean-Yves Wielandts, Kris Gillis, Michelle Lycke, Benjamin De Becker, Rene Tavernier, Jean-Benoit Le Polain De Waroux, Sebastien Knecht, and Mattias Duytschaever
- Published
- 2023
- Full Text
- View/download PDF
3. Evaluation of a standardized approach using optimized and contiguous RF applications for electrical isolation of the superior vena cava
- Author
-
Gabriela Hilfiker, Benjamin De Becker, Milad El. Haddad, Louisa O'Neill, Kris Gillis, Jean‐Yves Wielandts, René Tavernier, Jean‐Benoit Le Polain De Waroux, Mattias Duytschaever, and Sébastien Knecht
- Subjects
General Medicine ,Cardiology and Cardiovascular Medicine - Abstract
The superior vena cava (SVC) is well described as one of the most common non-pulmonary vein (PV)-triggers for atrial tachyarrhythmias (ATA). In our study we evaluated a standardized approach for electrical isolation of the SVC from the right atrium using a horseshoe-shaped lesion set with optimized and contiguous ostial RF lesions. The results are promising, demonstrating a very high rate of acute SVC isolation in a safe and time efficient manner (mostly less than 10 min).
- Published
- 2022
- Full Text
- View/download PDF
4. Vein of Marshall Ethanol Infusion as First Step for Mitral Isthmus Linear Ablation
- Author
-
Kris Gillis, Louisa O’Neill, Jean-Yves Wielandts, Gabriela Hilfiker, Alexandre Almorad, Michelle Lycke, Milad El Haddad, Jean-Benoît le Polain de Waroux, Rene Tavernier, Mattias Duytschaever, and Sebastien Knecht
- Subjects
Ethanol ,Atrial Fibrillation ,Catheter Ablation ,Humans ,Heart Atria ,Endocardium - Abstract
In this study, the authors sought to investigate the added value of vein of Marshall ethanol infusion (VOMEt) as first step in facilitating radiofrequency (RF)-guided mitral isthmus (MI) block.Achieving MI block with the use of RF ablation is challenging.Seventy patients planned for MI ablation were randomized 1:1 to VOMEt as a first step preceding RF (endocardial and epicardial, VOMIn VOMVOMEt as a first step in RF-guided MI line ablation significantly reduced the number of RF applications needed to achieve MI block, even if the sequence of the ablation steps did not affect the final incidence of block. (Evaluation of Vein of Marshall Ethanol Infusion During Left Atrial Linear Ablation in Patients With Persistent Atrial Fibrillation [MARSHALINE]; NCT04124328).
- Published
- 2022
- Full Text
- View/download PDF
5. Left bundle branch area pacing guided by continuous uninterrupted monitoring of unipolar pacing characteristics
- Author
-
Louisa O'Neill, Kris Gillis, Sébastien Knecht, Alina Vlase, Jean-Yves Wielandts, Gabriela Hilfiker, Mattias Duytschaever, Rene Tavernier, and Jean-Benoît le Polain de Waroux
- Subjects
Qrs morphology ,Bundle of His ,medicine.medical_specialty ,Perforation (oil well) ,Ventricular Septum ,Electrocardiography ,QRS complex ,Heart Conduction System ,Physiology (medical) ,Internal medicine ,Left bundle branch ,medicine ,Humans ,Lead (electronics) ,Aged ,Aged, 80 and over ,Pacing impedance ,business.industry ,Cardiac Pacing, Artificial ,Middle Aged ,Stylet ,Treatment Outcome ,Cardiology ,Cardiology and Cardiovascular Medicine ,business ,Continuous/uninterrupted - Abstract
INTRODUCTION During left bundle branch area pacing (LBBAP) lead implantation, intermittent monitoring of unipolar pacing characteristics confirms LBB capture and can detect septal perforation. We aimed to demonstrate that continuous uninterrupted unipolar pacing from an inserted lead stylet (LS) is feasible and facilitates LBBAP implantation. METHODS Thirty patients (mean age 76 ± 14 years) were implanted with a stylet-driven pacing lead (Biotronik Solia S60). In 10 patients (comparison-group) conventional implantation with interrupted unipolar pacing was performed, with comparison of unipolar pacing characteristics between LS and connector-pin (CP)-pacing after each rotation step. In 20 patients (uninterrupted-group) performance and safety of uninterrupted implantation during continuous pacing from the LS were evaluated. RESULTS In the comparison-group, LS and CP-pacing impedances were highly correlated (R2 =0.95, p
- Published
- 2021
- Full Text
- View/download PDF
6. Flatline on the alternate vector…Is this subcutaneous implantable cardiac defibrillator lead fractured?
- Author
-
Kris Gillis, Jean-Benoît le Polain de Waroux, Mattias Duytschaever, Louisa O'Neill, Rene Tavernier, Jean-Yves Wielandts, Sébastien Knecht, and Gabriela Hilfiker
- Subjects
medicine.medical_specialty ,business.industry ,Subcutaneous implantable cardiac defibrillator ,Case Report ,Device Complication ,Alternate vector flatline ,Lead fracture ,RC666-701 ,Internal medicine ,Device complication ,medicine ,Cardiology ,Diseases of the circulatory (Cardiovascular) system ,Flatline ,Automated screening tool ,Cardiology and Cardiovascular Medicine ,business ,Defibrillator lead - Published
- 2021
- Full Text
- View/download PDF
7. Early Experience with the Biotronik Protego ICD Lead
- Author
-
Thomas Seiler, Christian Grebmer, Gabriela Hilfiker, Richard Kobza, and Benjamin Berte
- Subjects
Protego ICD leads ,ICD ,lead failure ,General Medicine - Abstract
Background: In the last decade, newer generation ICD leads have been developed based on mechanistic insides of priorly failing leads. The aim of our study was to assess the long-term performance and mechanisms of failure of the 2013-introduced Biotronik Protego ICD lead in a real-world population. Methods: All patients, who underwent implantation of a Protego ICD lead at the Heart Centre Lucerne (Lucerne, Switzerland) between November 2013 and March 2017, were followed up with semi-annual device-controls. The primary endpoint was defined as lead failure, secondary endpoints compromised all-cause death, (in)appropriate shocks and the need for reintervention. Results: A total of 64 patients (mean age 66.7 ± 8.7 years, 30% female) underwent implantation of a Protego ICD lead: 78% for primary prevention, 53% had underlying ischemic heart disease, and 40.6% had a dilated cardiomyopathy (DCM). Mean left ventricular ejection fraction (LVEF) was 32.6 ± 10.5%. A total of 24 patients were treated with cardiac resynchronization therapy (CRT), and their baseline LVEF improved from 27.8 ± 7.3% before to 39.8 ± 12.5 after implantation (p < 0.001). Mean time to follow-up was 5.5 ± 0.9 years. Overall, 14 patients (26.6%) suffered from at least one episode of sustained ventricular tachycardia; in total 10 patients (15.6%) died. Two patients experienced lead failure due to lead fracture after 5.5 and 5.7 years, which was clinically apparent by an abrupt rise in lead impedance (>2000 Ω) and by repetitive inappropriate shocks, respectively. Conclusions: In this retrospective observational study, the calculated annual lead failure rate of the Biotronik Protego ICD lead was 0.59% per patient—thus, the durability and long-term performance seem to be promising.
- Published
- 2022
8. Permanent HIS bundle pacing – a valid alternative to biventricular cardiac resynchronization therapy?
- Author
-
Gabriela Hilfiker
- Subjects
Cardiology and Cardiovascular Medicine - Published
- 2022
- Full Text
- View/download PDF
9. Catheter Ablation in Persistent AF, the Evolution towards a More Pragmatic Strategy
- Author
-
Jean-Yves Wielandts, Louisa O'Neill, Gabriela Hilfiker, Jean-Benoît le Polain de Waroux, Rene Tavernier, Sébastien Knecht, Kris Gillis, and Mattias Duytschaever
- Subjects
persistent AF ,medicine.medical_specialty ,medicine.medical_treatment ,Population ,Catheter ablation ,Review ,Pulmonary vein ,Internal medicine ,medicine ,substrate ablation ,novel ablation technology ,education ,pulmonary vein isolation ,Heterogeneous disorder ,education.field_of_study ,business.industry ,Cardiac arrhythmia ,Atrial fibrillation ,General Medicine ,Ablation ,medicine.disease ,Catheter ,AF mapping ,Cardiology ,Medicine ,business - Abstract
Atrial fibrillation (AF) is the most common cardiac arrhythmia worldwide and represents a heterogeneous disorder with a complex pathological basis. While significant technological advances have taken place over the last decade in the field of catheter ablation of AF, response to ablation varies and long-term success rates in those with persistent AF remain modest. Mechanistic studies have highlighted potentially different sustaining factors for AF in the persistent AF population with substrate-driven focal and re-entrant sources in the body of the atria identified on invasive and non-invasive mapping studies. Translation to clinical practice, however, remains challenging and the application of such mapping techniques to clinical ablation has yet to demonstrate a significant benefit beyond pulmonary vein isolation (PVI) alone in the persistent AF cohort. Recent advances in catheter and ablation technology have centered on improving the durability of ablation lesions at index procedure and although encouraging results have been demonstrated with early studies, large-scale trials are awaited. Further meaningful improvement in clinical outcomes in the persistent AF population requires ongoing advancement in the understanding of AF mechanisms, coupled with continuing progress in catheter technology capable of delivering durable transmural lesions.
- Published
- 2021
10. Left bundle branch area pacing as alternative to his bundle pacing for cardiac resynchronisation therapy: a case report
- Author
-
Jean-Yves Wielandts, Rene Tavernier, Mattias Duytschaever, Alexandre Almorad, Gabriela Hilfiker, Jean-Benoît le Polain de Waroux, Anaïs Gauthey, Yves Vandekerckhove, Sébastien Knecht, UCL - SSS/IREC/CARD - Pôle de recherche cardiovasculaire, and UCL - (SLuc) Service de pathologie cardiovasculaire
- Subjects
physiologic pacing ,Bundle of His ,medicine.medical_specialty ,complication ,Ventricular Septum ,macromolecular substances ,030204 cardiovascular system & hematology ,Cardiac Resynchronization Therapy ,03 medical and health sciences ,0302 clinical medicine ,Heart Conduction System ,His bundle pacing ,Internal medicine ,Left bundle branch ,medicine ,Humans ,cardiovascular diseases ,030212 general & internal medicine ,cardiac resynchronisation therapy ,Ejection fraction ,left bundle area pacing ,Left bundle branch block ,business.industry ,Atrial fibrillation ,General Medicine ,medicine.disease ,humanities ,Heart failure ,Bundle ,cardiovascular system ,Cardiology ,CRT ,Cardiology and Cardiovascular Medicine ,Complication ,business ,circulatory and respiratory physiology - Abstract
Case description : A 74-year-old man suffering from severe heart failure (NYHA III – LVEF 28%) associated with left bundle branch block (LBBB) (Figure 1(A)) and uncontrolled permanent atrial fibrillation (AF) despite optimal medical treatment was referred for His ablation and rescue physiological pacing after a first unsuccessful LV lead implantation through the coronary sinus (CS). Careful review of the occluded CS angiogram indeed revealed no side branches. Concordantly, the patient was offered a ‘rescue’ HBP procedure. Using the SelectSecure lead (model 3830) and a C315 His sheath (Both Medtronic, Inc. MN), His mapping (HV ¼ 106ms) and recruitment were easily obtained, unfortunately without LBBB correction.
- Published
- 2020
- Full Text
- View/download PDF
11. Left Bundle Branch Area Pacing guided by Continuous Uninterrupted Monitoring of the unipolar Pacing Characteristics
- Author
-
Louisa O'Neill, Gabriela Hilfiker, Kris Gillis, Rene Tavernier, S Knecht, Jean-Benoît le Polain de Waroux, Alina Vlase, Mattias Duytschaever, and Jean-Yves Wielandts
- Subjects
Qrs morphology ,Pacing impedance ,medicine.medical_specialty ,business.industry ,Perforation (oil well) ,Stylet ,QRS complex ,Internal medicine ,Left bundle branch ,Cardiology ,medicine ,Lead (electronics) ,business ,Continuous/uninterrupted - Abstract
Introduction. During left bundle branch area pacing (LBBAP) lead implantation, intermittent monitoring of unipolar pacing characteristics validates LBB capture and can detect septal perforation. We aimed to demonstrate that continuous uninterrupted unipolar pacing from an inserted lead stylet (LS) is feasible and facilitates LBBAP implantation. Methods. Thirty patients (mean age 76 ± 14 years) were implanted with stylet-driven pacing lead (Biotronik Solia S60). In 10 patients (validation-group) conventional, interrupted implantation was performed, with comparison of unipolar pacing characteristics between LS and connector-pin (CP)-pacing after each rotation step. In 20 patients (feasibility-group) performance and safety of uninterrupted implantation during continuous pacing from the LS were analyzed. Results. In the validation-group, LS and CP-pacing impedances were highly correlated (R=0.95, p
- Published
- 2021
- Full Text
- View/download PDF
12. Biosense Webster's QDOT Micro™ radiofrequency ablation catheter
- Author
-
Kris Gillis, Jean-Yves Wielandts, Sébastien Knecht, Mattias Duytschaever, Benjamin Berte, Rene Tavernier, Milad El Haddad, Alexandre Almorad, Gabriela Hilfiker, Johan Vijgen, and Jean-Benoît le Polain de Waroux
- Subjects
Catheters ,Temperature sensing ,business.industry ,Catheter ,Radiofrequency ablation catheter ,Treatment Outcome ,Pulmonary Veins ,Atrial Fibrillation ,Catheter Ablation ,Molecular Medicine ,Medicine ,Humans ,Quality level ,Cardiology and Cardiovascular Medicine ,business ,Biomedical engineering - Abstract
The QDOT Micro™ catheter (Biosense Webster, Inc., CA, USA) is a new radiofrequency ablation catheter based on the SmartTouch SF™ (Biosense Webster, Inc.). It combines diffuse external irrigation with six thermocouples located within the outer metal shell and three additional microelectrodes in a 3.5 mm-tip contact force radiofrequency catheter. This article focuses on the different characteristics of the catheter, which incorporates the ability of high power delivery, irrigation flow control based on temperature sensing through the six thermocouples and the generation of microelectrograms. An outline of its performance in preclinical and clinical setting is presented, showing promising results, especially concerning procedural efficiency and short-term safety. Additional studies need to confirm long-term effectiveness, and durability studies should evaluate whether superiority on a lesion quality level can be achieved.Lay abstract Radiofrequency (RF) energy is the most widely used type of energy in the field of catheter ablation, an invasive treatment for heart rhythm disorders. In patients with atrial fibrillation (AF; the most frequent type of problem with the rhythm of the heart), catheter ablation aims at delivering RF energy around the pulmonary veins (PVs). PVs have been shown to contain AF triggers. Catheter ablation results in electrical isolation of the PV, making them less likely to trigger AF. The latest technical developments resulted in better success rate of the procedure (up to 90% success rate after 1 year follow-up) without increasing complication rates. During the last decade, the catheter used to isolate the PV has improved a lot and includes now contact force measurement in addition to the delivery mechanism for RF energy and can record the local electrical activity. The newly developed QDOT Micro™ catheter (Biosense Webster, Inc., CA, USA), presented in this article, combines different aspects of further technical development. These include the integration of smaller electrodes, resulting in higher local electrical signal resolution, more accurate feedback of local tissue temperature during the procedure and the ability to use higher RF power which reduces the RF delivery time and therefore reduced the duration of the procedure. An outline of its performance in preclinical and clinical setting is presented in this paper. These studies have shown promising results, especially concerning procedural efficiency and short-term safety. However, additional studies need to confirm long-term treatment success and potential superiority in comparison with other ablation approaches.
- Published
- 2021
13. B-AB21-05 ADDED VALUE OF VEIN OF MARSHAL ETHANOLISATION FOR MITRAL ISTHMUS LINE ABLATION. A RANDOMIZED STUDY
- Author
-
Mattias Duytschaever, Louisa O'Neill, Jean-Yves Wielandts, Rene Tavernier, Kris Gillis, Sébastien Knecht, Jean-Benoît le Polain de Waroux, and Gabriela Hilfiker
- Subjects
medicine.anatomical_structure ,business.industry ,Physiology (medical) ,medicine.medical_treatment ,Medicine ,Mitral isthmus ,Line (text file) ,Cardiology and Cardiovascular Medicine ,business ,Ablation ,Vein ,Nuclear medicine - Published
- 2021
- Full Text
- View/download PDF
14. Repositioning and Extraction of Stylet-Driven Pacing Leads with Extendable Helix used for Left Bundle Branch Area Pacing
- Author
-
Bert Geerts, Jean Yves Wielandts, Rene Tavernier, Sébastien Knecht, Antonio Sorgente, Jean-Benoît le Polain de Waroux, Gabriela Hilfiker, Kris Gillis, Lucio Capulzini, and Mattias Duytschaever
- Subjects
medicine.medical_specialty ,business.industry ,Computer science ,Acute complication ,030204 cardiovascular system & hematology ,Stylet ,03 medical and health sciences ,0302 clinical medicine ,Physiology (medical) ,Internal medicine ,Helix ,Left bundle branch ,medicine ,Cardiology ,030212 general & internal medicine ,Cardiology and Cardiovascular Medicine ,business ,Lead (electronics) - Abstract
Conventional stylet-driven leads with extendable helix can be implanted successfully for Left Bundle Branch Area Pacing (LBBAP) with a low acute complication rate. However, removal and repositioning techniques of these leads haven’t been yet described. We report 2 cases in which lead repositioning after a first unsuccessful attempt to LBBAP was associated with fracture of the helix rotating mechanism and failure to fully extract the pacing lead.
- Published
- 2021
- Full Text
- View/download PDF
15. Insights from Temperature Feedback and Current in Ablation Index-Guided Pulmonary Vein Isolation
- Author
-
Sébastien Knecht, Alexandre Almorad, Benjamin Berte, Federico Moccetti, Johan Vijgen, Saagar Mahida, Jean-Yves Wielandts, Pierre Jaïs, Thomas Phlips, Richard Kobza, and Gabriela Hilfiker
- Subjects
Physics ,Lesion ,business.industry ,medicine.medical_treatment ,medicine ,Right posterior ,medicine.symptom ,Ablation ,Nuclear medicine ,business ,Right anterior ,Pulmonary vein - Abstract
Objectives: To gain further knowledge of in-vivo lesion assessment and the complex regional interplay of lesion parameters during pulmonary vein isolation (PVI). Background: Although ablation index (AI) results in favourable outcomes of CLOSE protocol-guided PVI but its' relationship with other lesion parameters is not fully understood. Methods: 62 patients undergoing CLOSE-PVI (35-50W, {less than or equal to}6mm, AI 400-550) using a QDOT catheter were prospectively included. Lesion-specific data (impedance change [∆-IMP], current [mA], delivered energy [J], power [W], contact force [CF], thermocouple temperature [Temp] and micro-electrogram amplitude [ME-EGM]) were collected. Results: Although AI targets were reached for all 3166 lesions, 479 (15%) had very low ∆-IMP (
- Published
- 2021
- Full Text
- View/download PDF
16. Prospective Randomized Evaluation of High Power During CLOSE-Guided Pulmonary Vein Isolation: The POWER-AF Study
- Author
-
Gabriela Hilfiker, Michelle Lycke, Teresa Strisciuglio, Alexandre Almorad, Jean-Yves Wielandts, Maria Kyriakopoulou, Milad El Haddad, Yves Vandekerckhove, Jean-Benoît le Polain de Waroux, Rene Tavernier, Philippe Unger, Sébastien Knecht, Thomas Phlips, Mattias Duytschaever, Wielandts, Jean-Yve, Kyriakopoulou, Maria, 1, Alexandre Almorad, Hilfiker, Gabriela, Strisciuglio, Teresa, Phlips, Thoma, El Haddad, Milad, Lycke, Michelle, Unger, Philippe, Le Polain de Waroux, Jean-Benoît, Vandekerckhove, Yve, Tavernier, Rene, Duytschaever, Mattia, Knecht, Sebastien, UCL - SSS/IREC/CARD - Pôle de recherche cardiovasculaire, and UCL - (SLuc) Service de pathologie cardiovasculaire
- Subjects
Male ,Time Factors ,medicine.medical_treatment ,Operative Time ,radiofrequency catheter ablation ,Pulmonary vein ,power ,Heart Conduction System ,Heart Rate ,Recurrence ,biophysics ,Physiology (medical) ,Atrial Fibrillation ,medicine ,Humans ,Prospective Studies ,pulmonary vein ,business.industry ,Atrial fibrillation ,Middle Aged ,Ablation ,medicine.disease ,Treatment Outcome ,Surgery, Computer-Assisted ,Radiofrequency catheter ablation ,Pulmonary Veins ,Catheter Ablation ,Female ,Cardiology and Cardiovascular Medicine ,business ,Nuclear medicine ,Follow-Up Studies - Abstract
Background: CLOSE-guided atrial fibrillation (AF) ablation is based on contiguous (intertag distance ≤6 mm), optimized (Ablation Index >550 anteriorly and >400 posteriorly) point-by-point radiofrequency lesions. The optimal radiofrequency power remains unknown. Methods: The POWER-AF study is a prospective, randomized controlled monocentric study including patients with paroxysmal AF, planned for first CLOSE-guided pulmonary vein isolation using a contact force radiofrequency catheter (Thermocool SmartTouch, Biosense Webster, Inc, Irvine, CA). A total of 100 patients were randomized into 2 groups (1:1). The control group received AF ablation using the standard CLOSE protocol (35 W), whereas in the experimental group, pulmonary vein isolation was performed using high power (45 W). Endoscopic evaluation was performed in patients with intraesophageal temperature rise >38.5 °C. Results: The resulting sample size was 96 (48+48) patients. In the high power group, shorter procedure time (80 versus 102 minutes, P P P P P =0.31) showed an ulcerative perforation in a high power group patient (treated by endoscopic stenting and normalization after ≈4 months) and a superficial ulcerative lesion in a control group patient (conservative treatment). Both occurred following excessive Ablation Index applications (up to 460 and 480, respectively) with excessive contact force (30 g on average, with peaks up to 50 g). Six-months AF recurrence was not significantly different (10% in high power versus 8% in control, P =0.74). Conclusions: This randomized controlled study shows that a 45 W radiofrequency power CLOSE protocol in patients with paroxysmal AF significantly increases the global procedural efficiency with similar midterm efficacy. However, our study showed a narrower safety margin and a limited increased efficiency at the posterior wall using high power. This advocates against the use of high power in the region neighboring the esophagus.
- Published
- 2021
17. Image-guided ablation of scar-related ventricular tachycardia: towards a shorter and more predictable procedure
- Author
-
Gabriela Hilfiker, Benjamin Berte, Federico Moccetti, Lam Dang, Richard Kobza, Joel Bondietti, Frank Ruschitzka, Saagar Mahida, Hubert Cochet, Pierre Jaïs, Christoph Scharf, University of Zurich, and Berte, Benjamin
- Subjects
Male ,medicine.medical_treatment ,610 Medicine & health ,030204 cardiovascular system & hematology ,Ventricular tachycardia ,2705 Cardiology and Cardiovascular Medicine ,03 medical and health sciences ,Image guided ablation ,Cicatrix ,0302 clinical medicine ,2737 Physiology (medical) ,Physiology (medical) ,Medicine ,Fluoroscopy ,Humans ,030212 general & internal medicine ,Prospective Studies ,Aged ,Reproducibility ,Ejection fraction ,medicine.diagnostic_test ,business.industry ,Reproducibility of Results ,Magnetic resonance imaging ,Middle Aged ,Ablation ,medicine.disease ,Vt ablation ,Treatment Outcome ,Catheter Ablation ,Tachycardia, Ventricular ,10209 Clinic for Cardiology ,Female ,Cardiology and Cardiovascular Medicine ,business ,Nuclear medicine - Abstract
The aim of this study was to analyze the feasibility and reproducibility of using image integration software at a remote setting over the MUSIC network to perform image-guided VT ablation. Furthermore, we analyzed the efficacy of a focused workflow with electroanatomical mapping (EAM) limited to imaging-defined scar. In a prospective two-centre study, consecutive patients undergoing image integration-guided VT ablation (magnetic resonance [DE-MRI] and/or multidetector computed tomography [MDCT]) were included. Patients were divided into two groups (Group 1, complete EAM; Group 2, EAM limited to imaging-defined substrate). Forty-nine patients (62 ± 15 years; 90% male; LVEF 41 ± 14%; ischemic 69%) who underwent image integration-guided VT ablation were included (MDCT 98%; DE-MRI in 35%). Total procedure time was 172 ± 48 min (ablation 31 ± 17 min; fluoroscopy 23 ± 13 min). Procedure time was shorter in Group 2 as compared to Group 1 (Group 2 [n = 26] vs. Group 1 [n = 23]; procedure time: 151 ± 33 vs. 180 ± 53 min, P = 0.01). Non-inducibility of all VT was achieved in 37 (76%), with no difference between Group 1 and 2 (Group 2 vs. Group 1; VT non-inducibility 71 vs. 74%, P = 0.8). During a follow-up period of 19 ± 8 months, 13 patients (27%) had a VT recurrence. Two patients (4%) died during follow-up. There were no differences in VT-free survival between Group 1 and Group 2 (p = 0.77). Image-integrated VT ablation is feasible through a network between highly experienced centers and remotely located centers. Focused image integration-guided VT ablation is associated with short and predictable procedure duration, achieving high-long term success rates.
- Published
- 2020
- Full Text
- View/download PDF
18. Predictors of recurrence after durable pulmonary vein isolation for paroxysmal atrial fibrillation
- Author
-
Yves Vandekerckhove, Maria Kyriakopoulou, Milad El Haddad, Jean-Yves Wielandts, Michelle Lycke, Philippe Unger, Alexandre Almorad, Gabriela Hilfiker, Sébastien Knecht, Rene Tavernier, Jean-Benoît e Polain de Waroux, Teresa Strisciuglio, Mattias Duytschaever, Michael Wolf, Jan De Pooter, Lycke, M., Kyriakopoulou, M., El Haddad, M., Wielandts, J. -Y., Hilfiker, G., Almorad, A., Strisciuglio, T., De Pooter, J., Wolf, M., Unger, P., Vandekerckhove, Y., Tavernier, R., de Waroux, J. -B. E. P., Duytschaever, M., and Knecht, S.
- Subjects
Male ,medicine.medical_specialty ,Left atrium diameter ,Paroxysmal atrial fibrillation ,medicine.medical_treatment ,Left atrium ,Catheter ablation ,030204 cardiovascular system & hematology ,Pilmonary vein isolation ,Pulmonary vein ,03 medical and health sciences ,0302 clinical medicine ,Quality of life ,Recurrence ,Physiology (medical) ,Internal medicine ,Atrial Fibrillation ,medicine ,Humans ,030212 general & internal medicine ,Prospective Studies ,Diagnosis-to-ablation time ,Predictors ,business.industry ,Cardiac arrhythmia ,Atrial fibrillation ,Atrial fibrillation recurrence ,Middle Aged ,medicine.disease ,medicine.anatomical_structure ,Increased risk ,Treatment Outcome ,Pulmonary Veins ,Cardiology ,Catheter Ablation ,Quality of Life ,Female ,Cardiology and Cardiovascular Medicine ,business - Abstract
Aims Catheter ablation of paroxysmal atrial fibrillation (AF) reduces AF recurrence, AF burden, and improves quality of life. Data on clinical and procedural predictors of arrhythmia recurrence are scarce and are flawed by the high rate of pulmonary vein reconnection evidenced during repeat procedures after pulmonary vein isolation (PVI). In this study, we identified clinical and procedural predictors for AF recurrence 1 year after CLOSE-guided PVI, as this strategy has been associated with an increased PVI durability. Methods and results Patients with paroxysmal AF, who received CLOSE-guided PVI and who participated in a prospective trial in our centre, were included in this study. Uni- and multivariate models were plotted to find clinical and procedural predictors for AF recurrence within 1 year. Three hundred twenty-five patients with a mean age of 63 years (CHA2DS2VASc 1 [1–3], left atrium diameter 41 ± 6 mm) were included. About 60.9% were male individuals. After 1 year, AF recurrence occurred in 10.5% of patients. In a binary logistic regression analysis, the diagnosis-to-ablation time (DAT) was found to be the strongest predictor of AF recurrence (P = 0.011). Diagnosis-to-ablation time ≥1 year was associated with a nearly two-fold increased risk for developing AF recurrence. Conclusion The DAT is the most important predictor of arrhythmia recurrence in low-risk patients treated with durable pulmonary vein isolation for paroxysmal AF. Whether reducing the DAT could improve long-term outcomes should be investigated in another trial.
- Published
- 2020
19. Evaluation of higher power delivery during RF pulmonary vein isolation using optimized and contiguous lesions
- Author
-
Jan De Pooter, Teresa Strisciuglio, Thomas Phlips, Philippe Unger, Jean-Yves Wielandts, Yves Vandekerckhove, Maria Kyriakopoulou, Sébastien Knecht, Milad El Haddad, Alexandre Almorad, Michelle Lycke, Mattias Duytschaever, Rene Tavernier, Gabriela Hilfiker, Kyriakopoulou, M., Wielandts, J. -Y., Strisciuglio, T., El Haddad, M., Pooter, J. D., Almorad, A., Hilfiker, G., Phlips, T., Unger, P., Lycke, M., Vandekerckhove, Y., Tavernier, R., Duytschaever, M., and Knecht, S.
- Subjects
Male ,Time Factors ,Cardiologie et circulation ,medicine.medical_treatment ,Action Potentials ,Pilot Projects ,030204 cardiovascular system & hematology ,Pulmonary vein ,high power ablation ,0302 clinical medicine ,Postoperative Complications ,Heart Rate ,Recurrence ,Retrospective Studie ,Physiologie générale ,Atrial Fibrillation ,atrial fibrillation ,030212 general & internal medicine ,pulmonary vein isolation ,Atrial fibrillation ,Pulmonary Vein ,Middle Aged ,Ablation ,Treatment Outcome ,Pulmonary Veins ,Catheter Ablation ,Female ,medicine.symptom ,Cardiology and Cardiovascular Medicine ,Human ,Time Factor ,Paroxysmal atrial fibrillation ,Operative Time ,Catheter ablation ,Lesion ,03 medical and health sciences ,Physiology (medical) ,Heart rate ,medicine ,Humans ,Pilot Project ,Action Potential ,Retrospective Studies ,Aged ,business.industry ,Retrospective cohort study ,medicine.disease ,Postoperative Complication ,Nuclear medicine ,business ,contact force - Abstract
Aims: “CLOSE”-guided pulmonary vein isolation (PVI) is based on contiguous (≤6 mm) and optimized radiofrequency (RF) ablation lesions (ablation index [AI] ≥ 400 posteriorly and ≥ 550 anteriorly]. However, the optimal RF power to reach the desired AI is unknown. Therefore we evaluated the efficiency of an ablation strategy using higher power (40 W) during a first “CLOSE”-guided PVI. Methods: Eighty consecutive patients undergoing “CLOSE”-guided PVI for symptomatic paroxysmal atrial fibrillation were ablated with 40 W (group A). Results were compared with 105 consecutive patients enrolled in the “CLOSE to CURE”-study and were ablated using the same protocol with 35 W (group B). Results: In group A, ablation was associated with shorter ablation procedure time (91 vs 111 minutes; P .733) were similar in both groups (groups A and B, respectively). No complications occurred. In group A, a gastroscopy—performed in five patients with esophageal temperature rise more than 42°C—did not reveal any esophageal lesion. Postprocedural recurrence of atrial tachyarrhythmia at 1 year was not significantly different between both groups. Conclusions: Using the “CLOSE”-protocol, increased power increases the efficiency of PVI without compromising patients' safety., SCOPUS: ar.j, info:eu-repo/semantics/published
- Published
- 2020
20. Bumping-induced electrical dissociation of an arrhythmogenic fossa ovalis
- Author
-
Jean-Yves Wielandts, Gabriela Hilfiker, Rene Tavernier, Mattias Duytschaever, Sébastien Knecht, and Alexandre Almorad
- Subjects
Atrial Septum ,business.industry ,Arrhythmias, Cardiac ,Dissociation (chemistry) ,Nuclear magnetic resonance ,medicine.anatomical_structure ,Physiology (medical) ,Heart Septum ,Bumping ,Medicine ,Humans ,Fossa ovalis ,Cardiology and Cardiovascular Medicine ,business - Published
- 2020
21. Left Bundle Branch Area Pacing as an alternative to His Bundle pacing for Cardiac Resynchronization Therapy: a case report
- Author
-
Anais Gauthey, Jean-Yves Wielandts, Yves Vandekerckhove, Rene Tavernier, Mattias Duytschaever, Alexandre Almorad, S Knecht, Gabriela Hilfiker, and Jean-Benoît le Polain de Waroux
- Subjects
medicine.medical_specialty ,Ejection fraction ,Ventricular lead ,business.industry ,medicine.medical_treatment ,Cardiac resynchronization therapy ,medicine.disease ,QRS complex ,Bundle ,Heart failure ,Internal medicine ,Left bundle branch ,cardiovascular system ,medicine ,Cardiology ,cardiovascular diseases ,business ,Coronary sinus - Abstract
Biventricular pacing (BVP) has been demonstrated to improve functional outcomes and mortality of patients with symptomatic heart failure, reduced LVEF and wide QRS. Unfortunately, difficult coronary sinus anatomy can limit left ventricular lead placement. In such clinical situation, His Bundle Pacing (HBP) and Left Bundle Branch Area Pacing (LBBAP) have recently appeared as attractive alternatives to BVP. We describe the case of a patient with an indication for Cardiac Resynchronization Therapy (CRT) and AV node ablation, where left ventricular lead implantation and corrective HBP failed. LBBAP allowed for electrical and echocardiographic resynchronization with significant functional improvement.
- Published
- 2020
- Full Text
- View/download PDF
22. Hospital-integrated general practice: a promising way to manage walk-in patients in emergency departments
- Author
-
Gabriela Hilfiker, Corinne Chmiel, Klaus Eichler, Oliver Senn, Mathyas Wang, Thomas Rosemann, Stefanie Wild, and Patrick Sidler
- Subjects
medicine.medical_specialty ,Walk-in ,business.industry ,Health Policy ,Public Health, Environmental and Occupational Health ,Odds ratio ,Overcrowding ,medicine.disease ,Triage ,Confidence interval ,Ambulatory care ,Interquartile range ,Ambulatory ,Emergency medicine ,medicine ,Medical emergency ,business - Abstract
RATIONALE, AIMS AND OBJECTIVES: The inappropriate use and overcrowding of emergency departments (EDs) by walk-in patients are well-known problems in many countries. The current study aimed to determine whether ambulatory walk-in patients could be treated more efficiently in a new hospital-integrated general practice (HGP) for emergency care services compared to a traditional ED. METHODS: We conducted a pre-post comparison before and after the implementation of a new HGP. Participants were walk-in patients attending the ED of a city hospital in Zurich. Main outcome measures were differences in total process time, time intervals between stages of care and diagnostic resources used. RESULTS: The median process time from admission to discharge was 120 minutes in the ED [interquartile range (IQR): 80-165] versus 60 minutes in the HGP (IQR: 40-90) (P
- Published
- 2013
- Full Text
- View/download PDF
23. Utility of electrophysiological studies to predict arrhythmic events
- Author
-
Andreas W. Schoenenberger, Gabriela Hilfiker, Paul Erne, and Richard Kobza
- Subjects
congenital, hereditary, and neonatal diseases and abnormalities ,medicine.medical_specialty ,Pediatrics ,Ejection fraction ,Receiver operating characteristic ,Heart disease ,Proportional hazards model ,business.industry ,610 Medicine & health ,medicine.disease ,Sudden cardiac death ,hemic and lymphatic diseases ,Internal medicine ,Cohort ,medicine ,Clinical endpoint ,Cardiology ,Prospective Study ,Cardiology and Cardiovascular Medicine ,business ,Prospective cohort study - Abstract
AIM: To evaluate the prognostic value of electrophysiological stimulation (EPS) in the risk stratification for tachyarrhythmic events and sudden cardiac death (SCD). METHODS: We conducted a prospective cohort study and analyzed the long-term follow-up of 265 consecutive patients who underwent programmed ventricular stimulation at the Luzerner Kantonsspital (Lucerne, Switzerland) between October 2003 and April 2012. Patients underwent EPS for SCD risk evaluation because of structural or functional heart disease and/or electrical conduction abnormality and/or after syncope/cardiac arrest. EPS was considered abnormal, if a sustained ventricular tachycardia (VT) was inducible. The primary endpoint of the study was SCD or, in implanted patients, adequate ICD-activation. RESULTS: During EPS, sustained VT was induced in 125 patients (47.2%) and non-sustained VT in 60 patients (22.6%); in 80 patients (30.2%) no arrhythmia could be induced. In our cohort, 153 patients (57.7%) underwent ICD implantation after the EPS. During follow-up (mean duration 4.8 ± 2.3 years), a primary endpoint event occurred in 49 patients (18.5%). The area under the receiver operating characteristic curve (AUROC) was 0.593 (95%CI: 0.515-0.670) for a left ventricular ejection fraction (LVEF) < 35% and 0.636 (95%CI: 0.563-0.709) for inducible sustained VT during EPS. The AUROC of EPS was higher in the subgroup of patients with LVEF ≥ 35% (0.681, 95%CI: 0.578-0.785). Cox regression analysis showed that both, sustained VT during EPS (HR: 2.26, 95%CI: 1.22-4.19, P = 0.009) and LVEF < 35% (HR: 2.00, 95%CI: 1.13-3.54, P = 0.018) were independent predictors of primary endpoint events. CONCLUSION: EPS provides a benefit in risk stratification for future tachyarrhythmic events and SCD and should especially be considered in patients with LVEF ≥ 35%.
- Published
- 2015
- Full Text
- View/download PDF
24. Hospital-integrated general practice: a promising way to manage walk-in patients in emergency departments
- Author
-
Mathyas, Wang, Stefanie, Wild, Gabriela, Hilfiker, Corinne, Chmiel, Patrick, Sidler, Klaus, Eichler, Thomas, Rosemann, and Oliver, Senn
- Subjects
Adult ,Male ,Systems Integration ,Time Factors ,General Practice ,Ambulatory Care ,Humans ,Female ,Middle Aged ,Triage ,Emergency Service, Hospital - Abstract
The inappropriate use and overcrowding of emergency departments (EDs) by walk-in patients are well-known problems in many countries. The current study aimed to determine whether ambulatory walk-in patients could be treated more efficiently in a new hospital-integrated general practice (HGP) for emergency care services compared to a traditional ED.We conducted a pre-post comparison before and after the implementation of a new HGP. Participants were walk-in patients attending the ED of a city hospital in Zurich. Main outcome measures were differences in total process time, time intervals between stages of care and diagnostic resources used.The median process time from admission to discharge was 120 minutes in the ED [interquartile range (IQR): 80-165] versus 60 minutes in the HGP (IQR: 40-90) (P 0.001). The adjusted odds ratio of receiving any additional diagnostics was 1.86 (95% confidence interval 1.06-3.27; P = 0.032) for ED doctors versus general practitioners (GPs) when controlling for patients' age, sex and injury-related medical problems.The HGP is an efficient way to manage walk-in patients with regard to process time and utilization of additional diagnostic resources. The involvement of GPs in the HGPs should be considered as a promising model to overcome the inappropriate use of resources in EDs for walk-in patients who can be treated by ambulatory care.
- Published
- 2013
25. Utility of electrophysiological studies to predict arrhythmic events.
- Author
-
Hilfiker G, Schoenenberger AW, Erne P, and Kobza R
- Abstract
Aim: To evaluate the prognostic value of electrophysiological stimulation (EPS) in the risk stratification for tachyarrhythmic events and sudden cardiac death (SCD)., Methods: We conducted a prospective cohort study and analyzed the long-term follow-up of 265 consecutive patients who underwent programmed ventricular stimulation at the Luzerner Kantonsspital (Lucerne, Switzerland) between October 2003 and April 2012. Patients underwent EPS for SCD risk evaluation because of structural or functional heart disease and/or electrical conduction abnormality and/or after syncope/cardiac arrest. EPS was considered abnormal, if a sustained ventricular tachycardia (VT) was inducible. The primary endpoint of the study was SCD or, in implanted patients, adequate ICD-activation., Results: During EPS, sustained VT was induced in 125 patients (47.2%) and non-sustained VT in 60 patients (22.6%); in 80 patients (30.2%) no arrhythmia could be induced. In our cohort, 153 patients (57.7%) underwent ICD implantation after the EPS. During follow-up (mean duration 4.8 ± 2.3 years), a primary endpoint event occurred in 49 patients (18.5%). The area under the receiver operating characteristic curve (AUROC) was 0.593 (95%CI: 0.515-0.670) for a left ventricular ejection fraction (LVEF) < 35% and 0.636 (95%CI: 0.563-0.709) for inducible sustained VT during EPS. The AUROC of EPS was higher in the subgroup of patients with LVEF ≥ 35% (0.681, 95%CI: 0.578-0.785). Cox regression analysis showed that both, sustained VT during EPS (HR: 2.26, 95%CI: 1.22-4.19, P = 0.009) and LVEF < 35% (HR: 2.00, 95%CI: 1.13-3.54, P = 0.018) were independent predictors of primary endpoint events., Conclusion: EPS provides a benefit in risk stratification for future tachyarrhythmic events and SCD and should especially be considered in patients with LVEF ≥ 35%.
- Published
- 2015
- Full Text
- View/download PDF
Catalog
Discovery Service for Jio Institute Digital Library
For full access to our library's resources, please sign in.