1. Use of the CHA 2 DS 2 VASc score to reduce utilisation of transoesophageal echocardiography prior to ablation for atrial fibrillation.
- Author
-
Atkinson C, Hinton J, Gaisie EB, Yue AM, Roberts PR, Rakhit DJ, and Shah BN
- Abstract
Transoesophageal echocardiography (TOE) is frequently performed prior to atrial fibrillation (AF) ablation to exclude left atrial appendage (LAA) thrombus. However, patients undergoing AF ablation are usually anticoagulated, thus making the presence of thrombus unlikely in most cases. This study aimed to determine whether the CHA
2 DS2 VASc scoring system can be used to identify patients that do not require TOE prior to AF ablation. In this single-centre retrospective study, local institutional and primary care databases and electronic patient records were searched to identify patients that had undergone TOE prior to AF ablation. Patient demographics, CHA2 DS2 VASc score, TOE findings and anticoagulation status were collected for analysis. Over a 7-year period (2008-2014), 332 patients (age 57 ± 10 years; 74% male) underwent TOE prior to proposed AF ablation. CHA2 DS2 VASc scores of 0, 1, 2 and >2 were found in 39, 34, 15 and 12% of patients, respectively. The prevalence of LAA thrombus was 0.6% (2 patients) and these 2 patients had risk scores of 2 and 4. No patients with a score of 0 or 1 had LAA thrombus. Patients that are classed as low risk by the CHA2 DS2 VASc score do not require a pre-ablation TOE to screen for LAA thrombus provided they are adequately anticoagulated. This would lead to a significant reduction in health care expenditures by reducing unnecessary TOE requests and thereby improve patient experience., (© 2017 The authors.)- Published
- 2017
- Full Text
- View/download PDF