250 results on '"Grover, William H."'
Search Results
2. Error detection using pneumatic logic
- Author
-
Hoang, Shane, Shehada, Mabel, Patel, Zinal, Tran, Minh-Huy, Karydis, Konstantinos, Brisk, Philip, and Grover, William H.
- Subjects
Computer Science - Emerging Technologies ,Physics - Instrumentation and Detectors - Abstract
Pneumatic systems are common in manufacturing, healthcare, transportation, robotics, and many other fields. Failures in these systems can have very serious consequences, particularly if they go undetected. In this work, we present an air-powered error detector device that can detect and respond to failures in pneumatically actuated systems. The device contains 21 monolithic membrane valves that act like transistors in a pneumatic logic "circuit" that uses vacuum to represent TRUE and atmospheric pressure as FALSE. Three pneumatic exclusive-OR (XOR) gates are used to calculate the parity bit corresponding to the values of several control bits. If the calculated value of the parity bit differs from the expected value, then an error (like a leak or a blocked air line) has been detected and the device outputs a pneumatic error signal which can in turn be used to alert a user, shut down the system, or take some other action. As a proof-of-concept, we used our pneumatic error detector to monitor the operation of a medical device, an intermittent pneumatic compression (IPC) device commonly used to prevent the formation of life-threatening blood clots in the wearer's legs. Experiments confirm that when the IPC device was damaged, the pneumatic error detector immediately recognized the error (a leak) and alerted the wearer using sound. By providing a simple and low-cost way to add fault detection to pneumatic actuation systems without using sensors, our pneumatic error detector can promote safety and reliability across the wide range of pneumatic systems., Comment: 23 pages, 5 figures
- Published
- 2024
3. CandyCodes: simple universally unique edible identifiers for confirming the authenticity of pharmaceuticals
- Author
-
Grover, William H
- Subjects
Biomedical and Clinical Sciences ,Clinical Sciences ,Generic health relevance ,Fraud ,Humans ,Tablets ,World Health Organization - Abstract
Counterfeit or substandard medicines adversely affect the health of millions of people and cost an estimated $200 billion USD annually. Their burden is greatest in developing countries, where the World Health Organization estimates that one in ten medical products are fake. In this work, I describe a simple addition to the existing drug manufacturing process that imparts an edible universally unique physical identifier to each pill, tablet, capsule, caplet, etc. This technique uses nonpareils (also called sprinkles and "hundreds and thousands"), tiny inexpensive multicolor candy spheres that are normally added to other candies or desserts as decorations. If nonpareils are applied at random to a pill immediately after manufacture, the specific pattern they form is unlikely to ever be repeated by random chance; this means that the pattern (or "CandyCode") can be used to uniquely identify the pill and distinguish it from all other pills. By taking a photograph of each CandyCoded pill after manufacture and recording the location and color of each nonpareil, a manufacturer can construct a database containing the CandyCodes of all known-authentic pills they produce. A consumer can then simply use a cellphone to photograph a pill and transfer its image to the manufacturer's server, which determines whether the pill's CandyCode matches a known-good CandyCode in their database (meaning that the pill is authentic) or does not have a match in the database (in which case the consumer is warned that the pill may be counterfeit and should not be consumed). To demonstrate the feasibility of using random particles as universal identifiers, I performed a series of experiments using both real CandyCodes (on commercially produced chocolate candies) and simulated CandyCodes (generated by software). I also developed a simple method for converting a CandyCode photo to a set of strings for convenient storage and retrieval in a database. Even after subjecting CandyCodes to rough handling to simulate shipping conditions, the CandyCodes were still easily verifiable using a cellphone camera. A manufacturer could produce at least [Formula: see text] CandyCoded pills-41 million for each person on Earth-and still be able to uniquely identify each CandyCode. By providing universally-unique IDs that are easy to manufacture but hard to counterfeit, require no alteration of the existing drug formulation and minimal alteration of the manufacturing process, and need only a cameraphone for verification, CandyCodes could play an important role in the fight against fraud in pharmaceuticals and many other products.
- Published
- 2022
4. Dynamic Radial Placement and Routing in Paper Microfluidics
- Author
-
Potter, Joshua, Grover, William H, and Brisk, Philip
- Subjects
Bioengineering ,Biotechnology ,Layout ,Reservoirs ,Routing ,Physical design ,Substrates ,Geometry ,COVID-19 ,Continuous placement ,paper microfluidics ,placement and routing ,Electrical and Electronic Engineering ,Computer Hardware ,Computer Hardware & Architecture - Abstract
The low cost, simplicity, and ease of use of paper microfluidic devices have made them valuable medical diagnostics for applications from pregnancy testing to COVID-19 screening. Meanwhile, the increasing complexity of paper-based microfluidic devices is driving the need to produce new tools and methodologies that enable more robust biological diagnostics and potential therapeutic applications. A new design framework is being used to facilitate both research and fabrication of paper-based microfluidic biological devices to accelerate the investigative process and reduce material utilization and manpower. In this work we present a methodology for this framework to dynamically place and route microfluidic components in a nondiscrete design space where fluid volume usage, surface area utilization, and the timing required to perform specified biological assays are accounted for and optimized while also accelerating the development of potentially lifesaving new devices.
- Published
- 2021
5. A pneumatic random-access memory for controlling soft robots
- Author
-
Hoang, Shane, Karydis, Konstantinos, Brisk, Philip, and Grover, William H
- Subjects
Analog-Digital Conversion ,Artificial Intelligence ,Compressed Air ,Hand ,Humans ,Robotics ,Transistors ,Electronic ,General Science & Technology - Abstract
Pneumatically-actuated soft robots have advantages over traditional rigid robots in many applications. In particular, their flexible bodies and gentle air-powered movements make them more suitable for use around humans and other objects that could be injured or damaged by traditional robots. However, existing systems for controlling soft robots currently require dedicated electromechanical hardware (usually solenoid valves) to maintain the actuation state (expanded or contracted) of each independent actuator. When combined with power, computation, and sensing components, this control hardware adds considerable cost, size, and power demands to the robot, thereby limiting the feasibility of soft robots in many important application areas. In this work, we introduce a pneumatic memory that uses air (not electricity) to set and maintain the states of large numbers of soft robotic actuators without dedicated electromechanical hardware. These pneumatic logic circuits use normally-closed microfluidic valves as transistor-like elements; this enables our circuits to support more complex computational functions than those built from normally-open valves. We demonstrate an eight-bit nonvolatile random-access pneumatic memory (RAM) that can maintain the states of multiple actuators, control both individual actuators and multiple actuators simultaneously using a pneumatic version of time division multiplexing (TDM), and set actuators to any intermediate position using a pneumatic version of analog-to-digital conversion. We perform proof-of-concept experimental testing of our pneumatic RAM by using it to control soft robotic hands playing individual notes, chords, and songs on a piano keyboard. By dramatically reducing the amount of hardware required to control multiple independent actuators in pneumatic soft robots, our pneumatic RAM can accelerate the spread of soft robotic technologies to a wide range of important application areas.
- Published
- 2021
6. Measuring dissolution profiles of single controlled-release drug pellets.
- Author
-
Bhakta, Heran C, Lin, Jessica M, and Grover, William H
- Abstract
Many solid-dose oral drug products are engineered to release their active ingredients into the body at a certain rate. Techniques for measuring the dissolution or degradation of a drug product in vitro play a crucial role in predicting how a drug product will perform in vivo. However, existing techniques are often labor-intensive, time-consuming, irreproducible, require specialized analytical equipment, and provide only "snapshots" of drug dissolution every few minutes. These limitations make it difficult for pharmaceutical companies to obtain full dissolution profiles for drug products in a variety of different conditions, as recommended by the US Food and Drug Administration. Additionally, for drug dosage forms containing multiple controlled-release pellets, particles, beads, granules, etc. in a single capsule or tablet, measurements of the dissolution of the entire multi-particle capsule or tablet are incapable of detecting pellet-to-pellet variations in controlled release behavior. In this work, we demonstrate a simple and fully-automated technique for obtaining dissolution profiles from single controlled-release pellets. We accomplished this by inverting the drug dissolution problem: instead of measuring the increase in the concentration of drug compounds in the solution during dissolution (as is commonly done), we monitor the decrease in the buoyant mass of the solid controlled-release pellet as it dissolves. We weigh single controlled-release pellets in fluid using a vibrating tube sensor, a piece of glass tubing bent into a tuning-fork shape and filled with any desired fluid. An electronic circuit keeps the glass tube vibrating at its resonance frequency, which is inversely proportional to the mass of the tube and its contents. When a pellet flows through the tube, the resonance frequency briefly changes by an amount that is inversely proportional to the buoyant mass of the pellet. By passing the pellet back-and-forth through the vibrating tube sensor, we can monitor its mass as it degrades or dissolves, with high temporal resolution (measurements every few seconds) and mass resolution (700 nanogram resolution). As a proof-of-concept, we used this technique to measure the single-pellet dissolution profiles of several commercial controlled-release proton pump inhibitors in simulated stomach and intestinal contents, as well as comparing name-brand and generic formulations of the same drug. In each case, vibrating tube sensor data revealed significantly different dissolution profiles for the different drugs, and in some cases our method also revealed differences between different pellets from the same drug product. By measuring any controlled-release pellets, particles, beads, or granules in any physiologically-relevant environment in a fully-automated fashion, this method can augment and potentially replace current dissolution tests and support product development and quality assurance in the pharmaceutical industry.
- Published
- 2020
7. ChemStor: Using Formal Methods To Guarantee Safe Storage and Disposal of Chemicals
- Author
-
Ott, Jason, Tan, Daniel, Loveless, Tyson, Grover, William H, and Brisk, Philip
- Subjects
Laboratories ,United States ,Medicinal and Biomolecular Chemistry ,Theoretical and Computational Chemistry ,Computation Theory and Mathematics ,Medicinal & Biomolecular Chemistry - Abstract
While safe chemical storage and disposal are simple in principle-users should read safety specifications and place chemicals in appropriate cabinets or collection points-high-profile incidents involving improper storage and disposal of chemicals continue to occur. This paper introduces ChemStor, an open-source, automated computational system that can guarantee (mathematically verify a system is correct with respect to its specification), with regard to prescribed constraints, safe storage and disposal of chemicals used in academic, industrial, and domestic settings. ChemStor borrows concepts from formal methods-a branch of computer science capable of mathematically proving a specification or software is correct-to safely store or dispose of chemicals. If two or more chemicals can be combined in the same cabinet without forming possibly dangerous combinations of chemicals (while observing cabinet/shelf space constraints), then ChemStor determines that the storage configuration is safe. Likewise, if chemicals can be added to an existing disposal container without forming possibly dangerous combinations of chemicals (or exceeding the volume of the container), then ChemStor determines that the disposal configuration is safe. ChemStor accomplishes this by first building a chemical interaction graph, a graph that describes which chemicals may interact with each other based on their reactivity groups as determined by the United States Environmental Protection Agency. Next, ChemStor computes the chromatic number of the graph, the smallest number of colors used to color the graph such that no two vertices (chemicals) that share an edge (an interaction) share the same color. ChemStor then assigns all the chemicals of each color to a storage or disposal container after confirming that there is enough space in the container. These steps are encoded into a series of satisfiability modulo theory equations, and ChemStor uses an industry-standard tool to try to find a valid solution to these equations. The result is either a solution which dictates exactly where to store or dispose of each chemical, or an indication that no safe storage or disposal configuration could be found. To demonstrate the feasibility of ChemStor, we used the tool to analyze ten real-world chemical storage and disposal incidents that led to injuries or destruction of property. In each case, ChemStor quickly and successfully identified a proper chemical disposal or storage configuration that would have prevented the incident. In the future, ChemStor may be integrated with electronic laboratory notebooks, voice assistants, and other emerging technology to protect users of chemicals in labs, workplaces, and homes.
- Published
- 2020
8. Finding the optimal design of a passive microfluidic mixer.
- Author
-
Wang, Junchao, Zhang, Naiyin, Chen, Jin, Rodgers, Victor GJ, Brisk, Philip, and Grover, William H
- Subjects
Chemical Sciences ,Engineering ,Analytical Chemistry - Abstract
The ability to thoroughly mix two fluids is a fundamental need in microfluidics. While a variety of different microfluidic mixers have been designed by researchers, it remains unknown which (if any) of these mixers are optimal (that is, which designs provide the most thorough mixing with the smallest possible fluidic resistance across the mixer). In this work, we automatically designed and rationally optimized a microfluidic mixer. We accomplished this by first generating a library of thousands of different randomly designed mixers, then using the non-dominated sorting genetic algorithm II (NSGA-II) to optimize the random chips in order to achieve Pareto efficiency. Pareto efficiency is a state of allocation of resources (e.g. driving force) from which it is impossible to reallocate so as to make any one individual criterion better off (e.g. pressure drop) without making at least one individual criterion (e.g. mixing performance) worse off. After 200 generations of evolution, Pareto efficiency was achieved and the Pareto-optimal front was found. We examined designs at the Pareto-optimal front and found several design criteria that enhance the mixing performance of a mixer while minimizing its fluidic resistance; these observations provide new criteria on how to design optimal microfluidic mixers. Additionally, we compared the designs from NSGA-II with some popular microfluidic mixer designs from the literature and found that designs from NSGA-II have lower fluidic resistance with similar mixing performance. As a proof of concept, we fabricated three mixer designs from 200 generations of evolution and one conventional popular mixer design and tested the performance of these four mixers. Using this approach, an optimal design of a passive microfluidic mixer is found and the criteria of designing a passive microfluidic mixer are established.
- Published
- 2019
9. Differential densimetry: A method for determining ultra-low fluid flux and tissue permeability
- Author
-
Hale, Christopher S, Bhakta, Heran C, Jonak, Carrie R, Yonan, Jennifer M, Binder, Devin K, Grover, William H, and Rodgers, VGJ
- Subjects
Bioengineering ,Optical Physics ,Quantum Physics ,Electrical and Electronic Engineering - Abstract
Osmotic transport devices (OTDs) are forward osmosis membrane devices that we recently developed to remove accumulated fluid from swollen tissue, in-vivo, under severe conditions. As such, the relative volume of the fluid required to be removed and the volumetric flowrate may be two orders of magnitude less than the operating volume and tangential flowrate of the device. This makes it challenging to measure the rate of fluid flow from the swollen tissue. Here, we introduce a differential densimetry method for determining ultra-low volumetric flux through tissue samples. This technique uses two vibrating tube density sensors, one placed upstream of the membrane in contact with the tissue sample, and one placed downstream. Any flow of biological fluid withdrawn through the tissue will combine with the OTD operating fluid resulting in an observed density shift in the second density sensor. By measuring the difference in density between the upstream and downstream fluids, one can calculate the amount of fluid flowing across the tissue with a relatively high level of sensitivity. This method is also relatively insensitive to drift from temperature fluctuations and capable of continuously monitoring tissue permeability in real time. As a proof of concept, we used this technique to measure fluid flow across ex-vivo rat spinal tissue for an appropriately scaled OTD. The repeatability error had a maximum of only 12%. This implies that this method can provide highly acceptable flux measurements with reasonable reproducibility in real-time applications of fluid removal in-vivo.
- Published
- 2019
10. Using printer ink color to control the behavior of paper microfluidics.
- Author
-
Potter, Joshua, Brisk, Philip, and Grover, William H
- Subjects
Chemical Sciences ,Engineering ,Analytical Chemistry - Abstract
Paper microfluidic devices (including lateral flow assays) offer an excellent combination of utility and low cost. Many paper microfluidic devices are fabricated using the Xerox ColorQube line of commercial wax-based color printers; the wax ink serves as a hydrophobic barrier to fluid flow. These printers are capable of depositing four different colors of ink, cyan (C), magenta (M), yellow (Y), and black (K), plus 11 combinations of these colors (CM, CY, CK, MY, MK, YK, CMY, CMK, CYK, MYK, and CMYK), although most researchers use only black ink to print paper microfluidic devices. Recently, as part of a project to develop a computer-aided design framework for use with paper microfluidics devices, we unexpectedly observed that different colors of wax ink behave differently in paper microfluidics. We found that among the single colors of ink, black ink actually had the most barrier failures, and magenta ink had the fewest barrier failures. In addition, some combinations of colors performed even better than magenta: the combinations CY, MK, YK, CMY, CYK and MYK had no barrier failures in our study. We also found that the printer delivers significantly different amounts of ink to the paper for the different color combinations, and in general, the color combinations that formed the strongest barriers to fluid flow were the ones that had the most ink delivered to the paper. This suggests that by simply weighing paper samples printed with all 15 combinations of colors, one can easily find the color combinations most likely to form a strong barrier for a given printer. Finally, to show that deliberate choices of ink colors can actually be used to create new functions in paper microfluidics, we designed and tested a new color-based "antifuse" structure that protects paper microfluidic devices from a typical operator error (addition of too much fluid to the device). Our results provide a set of color choice guidelines that designers can use to control the behavior of their paper microfluidics.
- Published
- 2019
11. Chronoprints: Identifying Samples by Visualizing How They Change over Space and Time
- Author
-
McKenzie, Brittney A, Robles-Najar, Jessica, Duong, Eric, Brisk, Philip, and Grover, William H
- Subjects
Chemical Sciences - Abstract
The modern tools of chemistry excel at identifying a sample, but the cost, size, complexity, and power consumption of these instruments often preclude their use in resource-limited settings. In this work, we demonstrate a simple and low-cost method for identifying a sample based on visualizing how the sample changes over space and time in response to a perturbation. Different types of perturbations could be used, and in this proof-of-concept we use a dynamic temperature gradient that rapidly cools different parts of the sample at different rates. We accomplish this by first loading several samples into long parallel channels on a "microfluidic thermometer chip." We then immerse one end of the chip in liquid nitrogen to create a dynamic temperature gradient along the channels, and we use an inexpensive USB microscope to record a video of how the samples respond to the changing temperature gradient. The video is then converted into several bitmap images (one per sample) that capture each sample's response to the perturbation in both space (the y-axis; the distance along the dynamic temperature gradient) and time (the x-axis); we call these images "chronological fingerprints" or "chronoprints" of each sample. If two samples' chronoprints are similar, this suggests that the samples are the same chemical substance or mixture, but if two samples' chronoprints are significantly different, this proves that the samples are chemically different. Since chronoprints are just bitmap images, they can be compared using a variety of techniques from computer science, and in this work we use three different image comparison algorithms to quantify chronoprint similarity. As a demonstration of the versatility of chronoprints, we use them in three different applications: distinguishing authentic olive oil from adulterated oil (an example of the over $10 billion global problem of food fraud), identifying adulterated or counterfeit medication (which represents around 10% of all medication in low- and middle-income countries), and distinguishing the occasionally confused pharmaceutical ingredients glycerol and diethylene glycol (whose accidental or intentional substitution has led to hundreds of deaths). The simplicity and versatility of chronoprints should make them valuable analytical tools in a variety of different fields.
- Published
- 2019
12. Musical Instruments As Sensors
- Author
-
Bhakta, Heran C, Choday, Vamsi K, and Grover, William H
- Subjects
Bioengineering ,Chemical Engineering ,Materials Engineering - Abstract
The frequencies of notes made by a musical instrument are determined by the physical properties of the instrument. Consequently, by measuring the frequency of a note, one can infer information about the instrument's physical properties. In this work, we show that by modifying a musical instrument to contain a sample and analyzing the instrument's pitch, we can make precision measurements of the physical properties of the sample. We used the mbira, a 3000-year-old African musical instrument that consists of metal tines attached to a wooden board; these tines are plucked to play musical notes. By replacing the mbira's tines with bent steel tubing, filling the tubing with a sample, using a smartphone to record the sound while plucking the tubing, and measuring the frequency of the sound using a free software tool on our website, we can measure the density of the sample with a resolution of about 0.012 g/mL. Unlike existing tools for measuring density, the mbira sensor can be made and used by virtually anyone in the world. To demonstrate the mbira sensor's capabilities, we used it to successfully distinguish diethylene glycol and glycerol, two similar chemicals that are sometimes mistaken for each other in pharmaceutical manufacturing (leading to hundreds of deaths). We also show that consumers could use mbira sensors to detect counterfeit and adulterated medications (which represent around 10% of all medications in low- and middle-income countries). We expect that many other musical instruments can function as sensors and find important and lifesaving applications.
- Published
- 2018
13. MOPSA: A microfluidics-optimized particle simulation algorithm.
- Author
-
Wang, Junchao, Rodgers, Victor GJ, Brisk, Philip, and Grover, William H
- Subjects
Bioengineering ,Biotechnology ,Nanoscience & Nanotechnology ,Interdisciplinary Engineering ,Nanotechnology ,Classical Physics - Abstract
Computer simulation plays a growing role in the design of microfluidic chips. However, the particle tracers in some existing commercial computational fluid dynamics software are not well suited for accurately simulating the trajectories of particles such as cells, microbeads, and droplets in microfluidic systems. To address this issue, we present a microfluidics-optimized particle simulation algorithm (MOPSA) that simulates the trajectories of cells, droplets, and other particles in microfluidic chips with more lifelike results than particle tracers in existing commercial software. When calculating the velocity of a particle, MOPSA treats the particle as a two-dimensional rigid circular object instead of a single point. MOPSA also checks for unrealistic interactions between particles and channel walls and applies an empirical correcting function to eliminate these errors. To validate the performance of MOPSA, we used it to simulate a variety of important features of microfluidic devices like channel intersections and deterministic lateral displacement (DLD) particle sorter chips. MOPSA successfully predicted that different particle sizes will have different trajectories in six published DLD experiments from three research groups; these DLD chips were used to sort a variety of different cells, particles, and droplets. While some of these particles are not actually rigid or spherical, MOPSA's approximation of these particles as rigid spheres nonetheless resulted in lifelike simulations of the behaviors of these particles (at least for the particle sizes and types shown here). In contrast, existing commercial software failed to replicate these experiments. Finally, to demonstrate that MOPSA can be extended to simulate other properties of particles, we added support for simulating particle density to MOPSA and then used MOPSA to simulate the operation of a microfluidic chip capable of sorting cells by their density. By enabling researchers to accurately simulate the behavior of some types of particles in microfluidic chips before fabricating the chips, MOPSA should accelerate the development of new microfluidic devices for important applications.
- Published
- 2017
14. The Case for Semi-Automated Design of Microfluidic Very Large Scale Integration (mVLSI) Chips
- Author
-
McDaniel, Jeffrey, Grover, William H, and Brisk, Philip
- Subjects
Biotechnology - Abstract
In recent years, significant interest has emerged in the problem of fully automating the design of microfluidic very large scale integration (mVLSI) chips, a popular class of Lab-on-a-Chip (LoC) devices that can automatically execute a wide variety of biological assays. To date, this work has been carried out with little to no input from LoC designers. We conducted interviews with approximately 100 LoC designers, biologists, and chemists from academia and industry; uniformly, they expressed frustration with existing design solutions, primarily commercially available software such as AutoCAD and Solidworks; however, they expressed limited interest and considerable skepticism about the potential for 'push-button' end-to-end automation. In response, we have developed a semi-automated mVLSI drawing tool that is designed specifically to address the pain points elucidated by our interviewees. We have used this tool to rapidly reproduce several previously published LoC architectures and generate fabrication ready specifications.
- Published
- 2017
15. Measuring the mass, volume, and density of microgram-sized objects in fluid.
- Author
-
Mesbah Oskui, Shirin, Bhakta, Heran C, Diamante, Graciel, Liu, Huinan, Schlenk, Daniel, and Grover, William H
- Subjects
Animals ,Zebrafish ,Developmental Biology ,Environment ,Physical Phenomena ,General Science & Technology - Abstract
Measurements of an object's fundamental physical properties like mass, volume, and density can offer valuable insights into the composition and state of the object. However, many important biological samples reside in a liquid environment where it is difficult to accurately measure their physical properties. We show that by using a simple piece of glass tubing and some inexpensive off-the-shelf electronics, we can create a sensor that can measure the mass, volume, and density of microgram-sized biological samples in their native liquid environment. As a proof-of-concept, we use this sensor to measure mass changes in zebrafish embryos reacting to toxicant exposure, density changes in seeds undergoing rehydration and germination, and degradation rates of biomaterials used in medical implants. Since all objects have these physical properties, this sensor has immediate applications in a wide variety of different fields including developmental biology, toxicology, materials science, plant science, and many others.
- Published
- 2017
16. Sorting cells by their density.
- Author
-
Norouzi, Nazila, Bhakta, Heran C, and Grover, William H
- Subjects
Erythrocytes ,Leukocytes ,Humans ,Microfluidic Analytical Techniques ,Cell Count ,Cell Separation ,Microfluidics ,General Science & Technology - Abstract
Sorting cells by their type is an important capability in biological research and medical diagnostics. However, most cell sorting techniques rely on labels or tags, which may have limited availability and specificity. Sorting different cell types by their different physical properties is an attractive alternative to labels because all cells intrinsically have these physical properties. But some physical properties, like cell size, vary significantly from cell to cell within a cell type; this makes it difficult to identify and sort cells based on their sizes alone. In this work we continuously sort different cells types by their density, a physical property with much lower cell-to-cell variation within a cell type (and therefore greater potential to discriminate different cell types) than other physical properties. We accomplish this using a 3D-printed microfluidic chip containing a horizontal flowing micron-scale density gradient. As cells flow through the chip, Earth's gravity makes each cell move vertically to the point where the cell's density matches the surrounding fluid's density. When the horizontal channel then splits, cells with different densities are routed to different outlets. As a proof of concept, we use our density sorter chip to sort polymer microbeads by their material (polyethylene and polystyrene) and blood cells by their type (white blood cells and red blood cells). The chip enriches the fraction of white blood cells in a blood sample from 0.1% (in whole blood) to nearly 98% (in the output of the chip), a 1000x enrichment. Any researcher with access to a 3D printer can easily replicate our density sorter chip and use it in their own research using the design files provided as online Supporting Information. Additionally, researchers can simulate the performance of a density sorter chip in their own applications using the Python-based simulation software that accompanies this work. The simplicity, resolution, and throughput of this technique make it suitable for isolating even rare cell types in complex biological samples, in a wide variety of different research and clinical applications.
- Published
- 2017
17. A microfluidic thermometer: Precise temperature measurements in microliter- and nanoliter-scale volumes.
- Author
-
McKenzie, Brittney A and Grover, William H
- Subjects
Microfluidic Analytical Techniques ,Equipment Design ,Thermometers ,Temperature ,General Science & Technology - Abstract
Measuring the temperature of a sample is a fundamental need in many biological and chemical processes. When the volume of the sample is on the microliter or nanoliter scale (e.g., cells, microorganisms, precious samples, or samples in microfluidic devices), accurate measurement of the sample temperature becomes challenging. In this work, we demonstrate a technique for accurately determining the temperature of microliter volumes using a simple 3D-printed microfluidic chip. We accomplish this by first filling "microfluidic thermometer" channels on the chip with substances with precisely known freezing/melting points. We then use a thermoelectric cooler to create a stable and linear temperature gradient along these channels within a measurement region on the chip. A custom software tool (available as online Supporting Information) is then used to find the locations of solid-liquid interfaces in the thermometer channels; these locations have known temperatures equal to the freezing/melting points of the substances in the channels. The software then uses the locations of these interfaces to calculate the temperature at any desired point within the measurement region. Using this approach, the temperature of any microliter-scale on-chip sample can be measured with an uncertainty of about a quarter of a degree Celsius. As a proof-of-concept, we use this technique to measure the unknown freezing point of a 50 microliter volume of solution and demonstrate its feasibility on a 400 nanoliter sample. Additionally, this technique can be used to measure the temperature of any on-chip sample, not just near-zero-Celsius freezing points. We demonstrate this by using an oil that solidifies near room temperature (coconut oil) in a microfluidic thermometer to measure on-chip temperatures well above zero Celsius. By providing a low-cost and simple way to accurately measure temperatures in small volumes, this technique should find applications in both research and educational laboratories.
- Published
- 2017
18. Instantaneous simulation of fluids and particles in complex microfluidic devices
- Author
-
Wang, Junchao, Rodgers, Victor GJ, Brisk, Philip, and Grover, William H
- Subjects
Bioengineering ,Computer Simulation ,Equipment Design ,Lab-On-A-Chip Devices ,Microfluidic Analytical Techniques ,Software ,General Science & Technology - Abstract
Microfluidics researchers are increasingly using computer simulation in many different aspects of their research. However, these simulations are often computationally intensive: simulating the behavior of a simple microfluidic chip can take hours to complete on typical computing hardware, and even powerful workstations can lack the computational capabilities needed to simulate more complex chips. This slows the development of new microfluidic chips for new applications. To address this issue, we present a microfluidic simulation method that can simulate the behavior of fluids and particles in some typical microfluidic chips instantaneously (in around one second). Our method decomposes the chip into its primary components: channels and intersections. The behavior of fluid in each channel is determined by leveraging analogies with electronic circuits, and the behavior of fluid and particles in each intersection is determined by querying a database containing nearly 100,000 pre-simulated channel intersections. While constructing this database takes a nontrivial amount of computation time, once built, this database can be queried to determine the behavior of fluids and particles in a given intersection in a fraction of a second. Using this approach, the behavior of a microfluidic chip can be simulated in just one second on a standard laptop computer, without any noticeable degradation in the accuracy of the simulation. While our current technique has some constraints on the designs of the chips it can simulate (namely, T- or cross-shaped intersections, 90 degree channel turns, a fixed channel width, fluid flow rates between 0 and 2 cm/s, and particles with diameters between 1 and 20 microns), we provide several strategies for increasing the range of possible chip designs that can be simulated using our technique. As a proof of concept, we show that our simulation method can instantaneously simulate the paths followed by particles in both simple and complex microfluidic chips, with results that are essentially indistinguishable from simulations that took hours or even days to complete using conventional approaches.
- Published
- 2017
19. Poly(dimethylsiloxane) as a room-temperature solid solvent for photophysics and photochemistry
- Author
-
Clark, John, primary, Robinson, Samantha, additional, Espinoza, Eli M., additional, Bao, Duoduo, additional, Derr, James B., additional, Croft, Luca, additional, O'Mari, Omar, additional, Grover, William H., additional, and Vullev, Valentine Ivanov, additional
- Published
- 2024
- Full Text
- View/download PDF
20. Random design of microfluidics
- Author
-
Wang, Junchao, Brisk, Philip, and Grover, William H
- Subjects
Biotechnology ,Bioengineering ,Chemical Sciences ,Engineering ,Analytical Chemistry - Abstract
In this work we created functional microfluidic chips without actually designing them. We accomplished this by first generating a library of thousands of different random microfluidic chip designs, then simulating the behavior of each design on a computer using automated finite element analysis. The simulation results were then saved to a database which a user can query via to find chip designs suitable for a specific task. To demonstrate this functionality, we used our library to select chip designs that generate any three desired concentrations of a solute. We also fabricated and tested 16 chips from the library, confirmed that they function as predicted, and used these chips to perform a cell growth rate assay. This is one of many different applications for randomly-designed microfluidics; in principle, any microfluidic chip that can be simulated could be designed automatically using our method. Using this approach, individuals with no training in microfluidics can obtain custom chip designs for their own unique needs in just a few seconds.
- Published
- 2016
21. MECs: "Building Blocks" for Creating Biological and Chemical Instruments.
- Author
-
Hill, Douglas A, Anderson, Lindsey E, Hill, Casey J, Mostaghim, Afshin, Rodgers, Victor GJ, and Grover, William H
- Subjects
Humans ,Equipment Design ,Optics and Photonics ,Lab-On-A-Chip Devices ,General Science & Technology - Abstract
The development of new biological and chemical instruments for research and diagnostic applications is often slowed by the cost, specialization, and custom nature of these instruments. New instruments are built from components that are drawn from a host of different disciplines and not designed to integrate together, and once built, an instrument typically performs a limited number of tasks and cannot be easily adapted for new applications. Consequently, the process of inventing new instruments is very inefficient, especially for researchers or clinicians in resource-limited settings. To improve this situation, we propose that a family of standardized multidisciplinary components is needed, a set of "building blocks" that perform a wide array of different tasks and are designed to integrate together. Using these components, scientists, engineers, and clinicians would be able to build custom instruments for their own unique needs quickly and easily. In this work we present the foundation of this set of components, a system we call Multifluidic Evolutionary Components (MECs). "Multifluidic" conveys the wide range of fluid volumes MECs operate upon (from nanoliters to milliliters and beyond); "multi" also reflects the multiple disciplines supported by the system (not only fluidics but also electronics, optics, and mechanics). "Evolutionary" refers to the design principles that enable the library of MEC parts to easily grow and adapt to new applications. Each MEC "building block" performs a fundamental function that is commonly found in biological or chemical instruments, functions like valving, pumping, mixing, controlling, and sensing. Each MEC also has a unique symbol linked to a physical definition, which enables instruments to be designed rapidly and efficiently using schematics. As a proof-of-concept, we use MECs to build a variety of instruments, including a fluidic routing and mixing system capable of manipulating fluid volumes over five orders of magnitude, an acid-base titration instrument suitable for use in schools, and a bioreactor suitable for maintaining and analyzing cell cultures in research and diagnostic applications. These are the first of many instruments that can be built by researchers, clinicians, and students using the MEC system.
- Published
- 2016
22. Orientation-Based Control of Microfluidics.
- Author
-
Norouzi, Nazila, Bhakta, Heran C, and Grover, William H
- Subjects
Equipment Design ,Gravitation ,Rotation ,Lab-On-A-Chip Devices ,General Science & Technology - Abstract
Most microfluidic chips utilize off-chip hardware (syringe pumps, computer-controlled solenoid valves, pressure regulators, etc.) to control fluid flow on-chip. This expensive, bulky, and power-consuming hardware severely limits the utility of microfluidic instruments in resource-limited or point-of-care contexts, where the cost, size, and power consumption of the instrument must be limited. In this work, we present a technique for on-chip fluid control that requires no off-chip hardware. We accomplish this by using inert compounds to change the density of one fluid in the chip. If one fluid is made 2% more dense than a second fluid, when the fluids flow together under laminar flow the interface between the fluids quickly reorients to be orthogonal to Earth's gravitational force. If the channel containing the fluids then splits into two channels, the amount of each fluid flowing into each channel is precisely determined by the angle of the channels relative to gravity. Thus, any fluid can be routed in any direction and mixed in any desired ratio on-chip simply by holding the chip at a certain angle. This approach allows for sophisticated control of on-chip fluids with no off-chip control hardware, significantly reducing the cost of microfluidic instruments in point-of-care or resource-limited settings.
- Published
- 2016
23. Flow-Layer Physical Design for Microchips Based on Monolithic Membrane Valves
- Author
-
McDaniel, Jeffrey, Crites, Brian, Brisk, Philip, and Grover, William H
- Abstract
A software toolchain for physical design and layout for the flow layer of microfluidic laboratories on a chip ( LoCs) based on integrated microvalve technology is reported. LoCs based on monolithic membrane valves are built using two glass plates that sandwich a thin layer of polydimethylsiloxane (PDMS), a flexible and inert organic polymer. Etched channels in the two glass plates, respectively, provide distinct layers for fluid and pneumatic control. The biochemical reaction executes on the flow layer, while the control layer delivers pressure to each microvalve to control fluids in the flow layer. The planar layout for the fluid flow layer is converted to a scalable vector graphic (SVG) file, which can be used to create a mask that produces patterns for etched channels in one of the two glass layers. If a legal placement and routing solution is not found at N hops, then we try again at N=2 hops, etc. This ensures that a legal placement and routing solution is found for each perimeter component after O(log N) routing attempts. It is clear from a straightforward visual inspection that numerous local perturbations to the component layout could reduce chip area and/or fluid routing channel length.
- Published
- 2015
24. A spoonful of sugar can stop the (fake) medicine going down
- Author
-
Grover, William H., primary
- Published
- 2022
- Full Text
- View/download PDF
25. Measuring single cell mass, volume, and density with dual suspended microchannel resonators
- Author
-
Bryan, Andrea K, Hecht, Vivian C, Shen, Wenjiang, Payer, Kristofor, Grover, William H, and Manalis, Scott R
- Subjects
Rare Diseases ,Cancer ,Animals ,Cell Count ,Cell Line ,Tumor ,Cell Size ,Humans ,Mice ,Microfluidic Analytical Techniques ,Povidone ,Silicon Dioxide ,Chemical Sciences ,Engineering ,Analytical Chemistry - Abstract
Cell size, measured as either volume or mass, is a fundamental indicator of cell state. Far more tightly regulated than size is density, the ratio between mass and volume, which can be used to distinguish between cell populations even when volume and mass appear to remain constant. Here we expand upon a previous method for measuring cell density involving a suspended microchannel resonator (SMR). We introduce a new device, the dual SMR, as a high-precision instrument for measuring single-cell mass, volume, and density using two resonators connected by a serpentine fluidic channel. The dual SMR designs considered herein demonstrate the critical role of channel geometry in ensuring proper mixing and damping of pressure fluctuations in microfluidic systems designed for precision measurement. We use the dual SMR to compare the physical properties of two well-known cancer cell lines: human lung cancer cell H1650 and mouse lymphoblastic leukemia cell line L1210.
- Published
- 2014
26. Intracellular water exchange for measuring the dry mass, water mass and changes in chemical composition of living cells.
- Author
-
Feijó Delgado, Francisco, Cermak, Nathan, Hecht, Vivian C, Son, Sungmin, Li, Yingzhong, Knudsen, Scott M, Olcum, Selim, Higgins, John M, Chen, Jianzhu, Grover, William H, and Manalis, Scott R
- Subjects
Erythrocytes ,T-Lymphocytes ,Fibroblasts ,Animals ,Humans ,Mice ,Escherichia coli ,Saccharomyces cerevisiae ,Water ,Lipids ,Proteins ,DNA ,RNA ,Deuterium Exchange Measurement ,Biological Transport ,General Science & Technology - Abstract
We present a method for direct non-optical quantification of dry mass, dry density and water mass of single living cells in suspension. Dry mass and dry density are obtained simultaneously by measuring a cell's buoyant mass sequentially in an H2O-based fluid and a D2O-based fluid. Rapid exchange of intracellular H2O for D2O renders the cell's water content neutrally buoyant in both measurements, and thus the paired measurements yield the mass and density of the cell's dry material alone. Utilizing this same property of rapid water exchange, we also demonstrate the quantification of intracellular water mass. In a population of E. coli, we paired these measurements to estimate the percent dry weight by mass and volume. We then focused on cellular dry density - the average density of all cellular biomolecules, weighted by their relative abundances. Given that densities vary across biomolecule types (RNA, DNA, protein), we investigated whether we could detect changes in biomolecular composition in bacteria, fungi, and mammalian cells. In E. coli, and S. cerevisiae, dry density increases from stationary to exponential phase, consistent with previously known increases in the RNA/protein ratio from up-regulated ribosome production. For mammalian cells, changes in growth conditions cause substantial shifts in dry density, suggesting concurrent changes in the protein, nucleic acid and lipid content of the cell.
- Published
- 2013
27. Intracellular Water Exchange for Measuring the Dry Mass, Water Mass and Changes in Chemical Composition of Living Cells
- Author
-
Delgado, Francisco Feijó, Cermak, Nathan, Hecht, Vivian C, Son, Sungmin, Li, Yingzhong, Knudsen, Scott M, Olcum, Selim, Higgins, John M, Chen, Jianzhu, Grover, William H, and Manalis, Scott R
- Subjects
Biochemistry and Cell Biology ,Biological Sciences ,Generic health relevance ,Animals ,Biological Transport ,DNA ,Deuterium Exchange Measurement ,Erythrocytes ,Escherichia coli ,Fibroblasts ,Humans ,Lipids ,Mice ,Proteins ,RNA ,Saccharomyces cerevisiae ,T-Lymphocytes ,Water ,General Science & Technology - Abstract
We present a method for direct non-optical quantification of dry mass, dry density and water mass of single living cells in suspension. Dry mass and dry density are obtained simultaneously by measuring a cell's buoyant mass sequentially in an H2O-based fluid and a D2O-based fluid. Rapid exchange of intracellular H2O for D2O renders the cell's water content neutrally buoyant in both measurements, and thus the paired measurements yield the mass and density of the cell's dry material alone. Utilizing this same property of rapid water exchange, we also demonstrate the quantification of intracellular water mass. In a population of E. coli, we paired these measurements to estimate the percent dry weight by mass and volume. We then focused on cellular dry density - the average density of all cellular biomolecules, weighted by their relative abundances. Given that densities vary across biomolecule types (RNA, DNA, protein), we investigated whether we could detect changes in biomolecular composition in bacteria, fungi, and mammalian cells. In E. coli, and S. cerevisiae, dry density increases from stationary to exponential phase, consistent with previously known increases in the RNA/protein ratio from up-regulated ribosome production. For mammalian cells, changes in growth conditions cause substantial shifts in dry density, suggesting concurrent changes in the protein, nucleic acid and lipid content of the cell.
- Published
- 2013
28. Development and Evaluation of a Microdevice for Amino Acid Biomarker Detection and Analysis on Mars
- Author
-
Skelley, Alison M., Scherer, James R., Aubrey, Andrew D., Grover, William H., Ehrenfreund, Pascale, Grunthaner, Frank J., Bada, Jeffrey L., Mathies, Richard A., and Gray, Harry B.
- Published
- 2005
29. Using buoyant mass to measure the growth of single cells
- Author
-
Godin, Michel, Delgado, Francisco Feijó, Son, Sungmin, Grover, William H, Bryan, Andrea K, Tzur, Amit, Jorgensen, Paul, Payer, Kris, Grossman, Alan D, Kirschner, Marc W, and Manalis, Scott R
- Subjects
Bioengineering ,Generic health relevance ,Animals ,Bacillus subtilis ,Cell Cycle ,Cell Enlargement ,Escherichia coli ,Lymphocytes ,Mice ,Microfluidic Analytical Techniques ,Saccharomyces cerevisiae ,Biological Sciences ,Technology ,Medical and Health Sciences ,Developmental Biology - Abstract
We used a suspended microchannel resonator (SMR) combined with picoliter-scale microfluidic control to measure buoyant mass and determine the 'instantaneous' growth rates of individual cells. The SMR measures mass with femtogram precision, allowing rapid determination of the growth rate in a fraction of a complete cell cycle. We found that for individual cells of Bacillus subtilis, Escherichia coli, Saccharomyces cerevisiae and mouse lymphoblasts, heavier cells grew faster than lighter cells.
- Published
- 2010
30. Measuring the Physical Properties of Cells
- Author
-
Oskui, Shirin Mesbah, primary and Grover, William H., additional
- Published
- 2017
- Full Text
- View/download PDF
31. Design Automation of Paper Microfluidic Devices
- Author
-
Potter, Joshua, Brisk, Philip1, Grover, William H, Potter, Joshua, Potter, Joshua, Brisk, Philip1, Grover, William H, and Potter, Joshua
- Abstract
The emerging demands for healthcare where access is limited due to political, environmental, or socio-economic factors have been driving research into bio-medical devices that perform in both diagnostic and therapeutic roles at lower costs and greater accessibility. Paper microfluidic devices are used in many applications, particularly medical diagnostics and offer an excellent combination of utility and low cost making them particularly valuable in resource-limited applications and point-of-care usage across a wide variety environmental conditions. Microfluidic biological diagnostics continue to mature as researchers discover new ways to exploit the technological possibilities, and address liabilities. The increasing complexity of paper-based microfluidic devices beyond home pregnancy tests is driving the need to produce new tools and methodologies that enable more robust biological diagnostics and potential therapeutic applications. However, the process of developing new paper microfluidic devices is limited due to having to manually design and fabricate designs to research. Often, researchers must design scores of different devices to find a combination of parameters that functions as expected. In this work, a novel software framework to support automated development of paper-based microfluidic devices is introduced to facilitate both research and fabrication to accelerate the investigative process and reduce material utilization and manpower. Unlike to existing lab-on-a-chip technologies, paper-based microfluidics differs in terms of substrate technologies and use a passive flow method to deliver fluids and reagents for assays. While numerous analogies between microfluidics and semiconductor technologies have been espoused, the physical differences between the fluid dynamics and electrical current are significant which suggests that current trends in physical design for microfluidics must change course in order to be of practical use to designers. Within this fr
- Published
- 2022
32. Measuring single-cell density
- Author
-
Grover, William H., Bryan, Andrea K., diez-Silva, Monica, Suresh, Subra, Higgins, John M., and Manalis, Scott R.
- Published
- 2011
33. Multi-Objective Design Automation for Microfluidic Capture Chips
- Author
-
Chen, Lisa, primary, Grover, William H., additional, Sridharan, Manu, additional, and Brisk, Philip, additional
- Published
- 2022
- Full Text
- View/download PDF
34. Rapid development and optimization of paper microfluidic designs using software automation
- Author
-
Potter, Joshua, primary, Brisk, Philip, additional, and Grover, William H., additional
- Published
- 2021
- Full Text
- View/download PDF
35. Practical Valves and Pumps for Large-Scale Integration into Microfluidic Analysis Devices
- Author
-
Grover, William H., Skelley, Alison M., Liu, Chung N., Lagally, Eric T., Mathies, Richard A., Baba, Yoshinobu, editor, Shoji, Shuichi, editor, and van den Berg, Albert, editor
- Published
- 2002
- Full Text
- View/download PDF
36. CandyCodes: Simple universally unique edible identifiers for confirming the authenticity of pharmaceuticals
- Author
-
Grover, William H., primary
- Published
- 2021
- Full Text
- View/download PDF
37. Multi-Objective Design Automation for Microfluidic Capture Chips
- Author
-
Chen, Lisa, Grover, William H., Sridharan, Manu, and Brisk, Philip
- Abstract
Microfluidic capture chips are useful for preparing or analyzing a wide range of different chemical, biological, and medical samples. A typical microfluidic capture chip contains features that capture certain targets (i.e. molecules, particles, cells) as they flow through the chip. However, creating optimal capture chip designs is difficult because of the inherent relationship between capture efficiency and flow resistance: as more capture features are added to the chip, the capture efficiency increases, but the additional features slow the flow of fluid through the chip. This paper introduces the use of multi-objective optimization to generate capture chip designs that balance the trade-off between maximizing target capture efficiency and minimizing resistance to fluid flow. Design automation for this important class of microfluidic chips has not been attempted previously. Our approach automatically produces a Pareto front of non-dominated chip designs in a reasonable amount of time, and most of these designs have comparable capture efficiency to hand-designed chips with far lower flow resistance. By choosing from the chip designs on the Pareto front, a user can obtain high capture efficiency without exceeding the flow resistance constraints of their application.
- Published
- 2023
- Full Text
- View/download PDF
38. Suspended microchannel resonators for ultralow volume universal detection
- Author
-
Son, Sungmin, Grover, William H., Burg, Thomas P., and Manalis, Scott R.
- Subjects
Resonators -- Properties ,Nanotechnology -- Research ,Specific gravity -- Research ,Fluidic devices -- Properties ,Fluidic devices -- Usage ,Chemistry - Abstract
Universal detectors that maintain high sensitivity as the detection volume is reduced to the subnanoliter scale can enhance the utility of miniaturized total analysis systems ([mu]-TAS). Here the unique scaling properties of the suspended microchannel resonator (SMR) are exploited to show universal detection in a 10 pL analysis volume with a density detection limit of ~1 [micro]g/[cm.sup.3] (10 Hz bandwidth) and a dynamic range of 6 decades. Analytes with low IN extinction coefficients such as polyethylene glycol (PEG) 8 kDa, glucose, and glycine are measured with molar detection limits of 0.66, 13.5, and 31.6 [micro]M, respectively. To demonstrate the potential for real-time monitoring, gel titration chromatography was used to separate different molecular weights of PEG as the SMR acquired a chromatogram by measuring the eluate density. This work suggests that the SMR could offer a simple and sensitive universal detector for various separation systems from liquid chromatography to capillary electrophoresis. Moreover, since the SMR is itself a microfluidic channel, it can be directly integrated into [mu]-TAS without compromising overall performance.
- Published
- 2008
39. Micropneumatic digital logic structures for integrated microdevice computation and control
- Author
-
Jensen, Erik C., Grover, William H., and Mathies, Richard A.
- Subjects
Central processing units -- Equipment and supplies ,Microprocessors -- Equipment and supplies ,Pneumatic control -- Research ,Microelectromechanical systems -- Control ,Microprocessor ,Microprocessor upgrade ,Engineering and manufacturing industries ,Science and technology - Abstract
It is shown that microfabricated polydimethylsiloxane membrane valve structures can be configured to function as transistors in pneumatic digital logic circuits. Using the analogy with metal-oxide-semiconductor field-effect transistor circuits, networks of pneumatically actuated microvalves are designed to produce pneumatic digital logic gates (AND, OR, NOT, NAND, and XOR). These logic gates are combined to form 4- and 8-bit ripple-carry adders as a demonstration of their universal pneumatic computing capabilities. Signal propagation through these pneumatic circuits is characterized, and an amplifier circuit is demonstrated for improved signal transduction. Propagation of pneumatic carry information through the 8-bit adder is complete within 1.1 s, demonstrating the feasibility of integrated temporal control of pneumatic actuation systems. Integrated pneumatic logical systems reduce the number of off-chip controllers required for lab-on-a-chip and microelectromechanical system devices, allowing greater complexity and portability. This technology also enables the development of digital pneumatic computing and logic systems that are immune to electromagnetic interference. [2006-0290] Index Terms--Lab-on-a-chip, microfluidics, microprocessors, microvalves, pneumatic logic.
- Published
- 2007
40. Microfluidic serial dilution circuit
- Author
-
Paegel, Brian M., Grover, William H., Skelley, Alison M., Mathies, Richard A., and Joyce, Gerald F.
- Subjects
Dilution -- Research ,Chemistry - Abstract
In vitro evolution of RNA molecules requires a method for executing many consecutive serial dilutions. To solve this problem, a microfluidic circuit has been fabricated in a three-layer glass--PDMS--glass device. The 400-nL serial dilution circuit contains five integrated membrane valves: three two-way valves arranged in a loop to drive cyclic mixing of the diluent and carryover, and two bus valves to control fluidic access to the circuit through input and output channels. By varying the valve placement in the circuit, carryover fractions from 0.04 to 0.2 were obtained. Each dilution process, which is composed of a diluent flush cycle followed by a mixing cycle, is carded out with no pipeting, and a sample volume of 400 nL is sufficient for conducting an arbitrary number of serial dilutions. Mixing is precisely controlled by changing the cyclic pumping rate, with a minimum mixing time of 22 s. This microfluidic circuit is generally applicable for integrating automated serial dilution and sample preparation in almost any microfluidic architecture.
- Published
- 2006
41. Fluid control structures in microfluidic devices
- Author
-
Mathies, Richard A, Grover, William H, Skelley, Alison, Lagally, Eric, and Liu, Chung N
- Subjects
Instrumentation And Photography - Abstract
Methods and apparatus for implementing microfluidic analysis devices are provided. A monolithic elastomer membrane associated with an integrated pneumatic manifold allows the placement and actuation of a variety of fluid control structures, such as structures for pumping, isolating, mixing, routing, merging, splitting, preparing, and storing volumes of fluid. The fluid control structures can be used to implement a variety of sample introduction, preparation, processing, and storage techniques.
- Published
- 2008
42. Sensitive Amino Acid Composition and Chirality Analysis with the Mars Organic Analyzer (MOA)
- Author
-
Skelley, Alison M, Scherer, James R, Aubrey, Andrew D, Grover, William H, Ivester, Robin H. C, Ehrenfreund, Pascale, Grunthaner, Frank J, Bada, Jeffrey L, and Mathies, Richard A
- Subjects
Lunar And Planetary Science And Exploration - Abstract
Detection of life on Mars requires definition of a suitable biomarker and development of sensitive yet compact instrumentation capable of performing in situ analyses. Our studies are focused on amino acid analysis because amino acids are more resistant to decomposition than other biomolecules, and because amino acid chirality is a well-defined biomarker. Amino acid composition and chirality analysis has been previously demonstrated in the lab using microfabricated capillary electrophoresis (CE) chips. To analyze amino acids in the field, we have developed the Mars Organic Analyzer (MOA), a portable analysis system that consists of a compact instrument and a novel multi-layer CE microchip.
- Published
- 2005
43. Monolithic membrane valves and diaphragm pumps for practical large-scale integration into glass microfluidic devices
- Author
-
Grover, William H, Skelley, Alison M, Liu, Chung N, Lagally, Eric T, and Mathies, Richard A
- Published
- 2003
- Full Text
- View/download PDF
44. Localized deposition of zinc oxide films by automated fluid dispensing method
- Author
-
Domansky, Karel, Rose, Aimee, Grover, William H, and Exarhos, Gregory J
- Published
- 2000
- Full Text
- View/download PDF
45. Accelerating Simulation of Particle Trajectories in Microfluidic Devices by Constructing a Cloud Database
- Author
-
Wang, Junchao, primary, Fu, Lingxuan, additional, Yu, Liyang, additional, Huang, Xiwei, additional, Brisk, Philip, additional, and Grover, William H., additional
- Published
- 2018
- Full Text
- View/download PDF
46. Stimulation or Activation of Eosinophils in Vivo during Eosinophilia: Possible Role of Arachidonic Acid Metabolism
- Author
-
Bass, David A., Grover, William H., Lewis, Jon C., DeChatelet, Lawrence R., McCall, Charles E., Rossi, Filippo, editor, and Patriarca, Pierluigi, editor
- Published
- 1982
- Full Text
- View/download PDF
47. The case for semi-automated design of microfluidic very large scale integration (mVLSI) chips
- Author
-
McDaniel, Jeffrey, primary, Grover, William H., additional, and Brisk, Philip, additional
- Published
- 2017
- Full Text
- View/download PDF
48. Quantitative FRET (qFRET) Technology for Determination of Protein Interaction Dissociation Constant in the Presence of Other Proteins and Development of Microfluidic Device
- Author
-
Kung, Raphael Chih-Chung, Liao, Jiayu1, Grover, William H, Kung, Raphael Chih-Chung, Kung, Raphael Chih-Chung, Liao, Jiayu1, Grover, William H, and Kung, Raphael Chih-Chung
- Abstract
Post-translational modification is one of the most vital functions at the cellular level in the human body. Ubiquitin and the Ubiquitin-like modifiers (Ubl's) are one class of post-translational modifier. They are involved in a variety of processes including transcription, DNA repair, and tumor progression. Each Ubl alters its target substrates through a 3 step enzymatic cascade of activation by E1, conjugation by E2, and ligation by E3. Our lab has developed a powerful Quantitative FRET analysis method to study the interactions at each step of the post-translational pathway. There are, however, less optimal components of the experimental procedure. The goal of my research is to increase the efficiency of lab protocol by determination of the effect of applying quantitative FRET measurements to unpurified proteins, and explore the possibility of integrating our quantitative FRET technology with microfluidics to enhance the efficiency of lab work.
- Published
- 2015
49. Measuring single cell mass, volume, and density with dual suspended microchannel resonators
- Author
-
Massachusetts Institute of Technology. Department of Biological Engineering, Massachusetts Institute of Technology. Microsystems Technology Laboratories, Koch Institute for Integrative Cancer Research at MIT, Bryan, Andrea K., Hecht, Vivian Chaya, Payer, Kristofor Robert, Grover, William H., Manalis, Scott R., Shen, Wenjiang, Bryan, Andrea Kristine, Manalis, Scott R, Massachusetts Institute of Technology. Department of Biological Engineering, Massachusetts Institute of Technology. Microsystems Technology Laboratories, Koch Institute for Integrative Cancer Research at MIT, Bryan, Andrea K., Hecht, Vivian Chaya, Payer, Kristofor Robert, Grover, William H., Manalis, Scott R., Shen, Wenjiang, Bryan, Andrea Kristine, and Manalis, Scott R
- Abstract
Cell size, measured as either volume or mass, is a fundamental indicator of cell state. Far more tightly regulated than size is density, the ratio between mass and volume, which can be used to distinguish between cell populations even when volume and mass appear to remain constant. Here we expand upon a previous method for measuring cell density involving a suspended microchannel resonator (SMR). We introduce a new device, the dual SMR, as a high-precision instrument for measuring single-cell mass, volume, and density using two resonators connected by a serpentine fluidic channel. The dual SMR designs considered herein demonstrate the critical role of channel geometry in ensuring proper mixing and damping of pressure fluctuations in microfluidic systems designed for precision measurement. We use the dual SMR to compare the physical properties of two well-known cancer cell lines: human lung cancer cell H1650 and mouse lymphoblastic leukemia cell line L1210., National Cancer Institute (U.S.) (Koch Institute Support (Core) Grant P30-CA14051), National Cancer Institute (U.S.). Physical Sciences Oncology Center (U54CA143874), National Cancer Institute (U.S.). Cell Decision Process Center (P50GM68762), National Institutes of Health (U.S.) (Contract R01GM085457)
- Published
- 2015
50. Assessing and Reducing the Toxicity of 3D-Printed Parts
- Author
-
Oskui, Shirin Mesbah, primary, Diamante, Graciel, additional, Liao, Chunyang, additional, Shi, Wei, additional, Gan, Jay, additional, Schlenk, Daniel, additional, and Grover, William H., additional
- Published
- 2015
- Full Text
- View/download PDF
Catalog
Discovery Service for Jio Institute Digital Library
For full access to our library's resources, please sign in.