35 results on '"Hunt LW"'
Search Results
2. Case & comment. Hives, oral allergy syndrome, and more.
- Author
-
Mahmoudi M, Hunt LW, and Saunders cs
- Published
- 1999
3. Treatment of asthma with nebulized lidocaine: a randomized, placebo-controlled study.
- Author
-
Hunt LW, Frigas E, Butterfield JH, Kita H, Blomgren J, Dunnette SL, Offord KP, and Gleich GJ
- Subjects
- Administration, Inhalation, Adolescent, Adult, Anti-Asthmatic Agents adverse effects, Asthma blood, Asthma physiopathology, Eosinophils, Female, Forced Expiratory Volume, Glucocorticoids administration & dosage, Humans, Leukocyte Count, Lidocaine adverse effects, Male, Middle Aged, Nebulizers and Vaporizers, Safety, Anti-Asthmatic Agents administration & dosage, Asthma drug therapy, Lidocaine administration & dosage
- Abstract
Background: In 2 prior uncontrolled studies, nebulized lidocaine reduced oral glucocorticoid use in patients with severe glucocorticoid-dependent asthma., Objective: We tested the safety and efficacy of nebulized lidocaine in a randomized, placebo-controlled study in patients with mild-to-moderate asthma., Methods: We recruited 50 subjects (25 receiving lidocaine and 25 receiving placebo); all had a prebronchodilator FEV(1) of 64% to 125% of predicted normal value and were treated with daily inhaled glucocorticoids (but not systemic glucocorticoids) and bronchodilators for at least 2 months. Before treatment, subjects monitored their symptoms and peak flow values and maintained their medications for 2 weeks. At initiation, subjects inhaled either nebulized placebo (saline) or lidocaine (4%, 100 mg) 4 times daily. All subjects were instructed to reduce their inhaled glucocorticoid dosage by one half each week for 3 weeks and to discontinue glucocorticoid treatment at week 4. The subjects continued the nebulized lidocaine or placebo for a total of 8 weeks, monitored their symptoms, and used bronchodilators to control symptoms., Results: Indicators of asthma severity showed benefit for the lidocaine-treated group: changes in FEV(1) (P < or =.001), nighttime awakenings (P < or =.02), symptoms (P < or =.010), bronchodilator use (P < or =.010), and blood eosinophil counts (P < or =.020). Subjects in both groups reduced use of inhaled glucocorticoids comparably. Subjects receiving nebulized placebo showed increases in their symptom scores, bronchodilator use (P < or =.05 for both), and blood eosinophil counts (P < or =.01) and decreases in FEV(1) (P < or =.001)., Conclusion: Nebulized lidocaine provided effective and safe therapy in subjects with mild-to-moderate asthma.
- Published
- 2004
- Full Text
- View/download PDF
4. Management of occupational allergy to natural rubber latex in a medical center: the importance of quantitative latex allergen measurement and objective follow-up.
- Author
-
Hunt LW, Kelkar P, Reed CE, and Yunginger JW
- Subjects
- Air Pollutants, Occupational adverse effects, Allergens adverse effects, Follow-Up Studies, Gloves, Protective adverse effects, Health Personnel, Humans, Latex adverse effects, Latex Hypersensitivity etiology, Occupational Diseases etiology, Rubber adverse effects, Time Factors, Air Pollutants, Occupational analysis, Allergens analysis, Environmental Monitoring methods, Latex analysis, Latex Hypersensitivity prevention & control, Occupational Diseases prevention & control
- Abstract
When our employees began coming to the Occupational Health Service, Dermatology, and Allergy Clinics with symptoms of allergy to rubber gloves 12 years ago, the Mayo Clinic initiated 3 responses. (1) The Allergic Disease Research Laboratory adapted well-established technology to measure both the IgE antibody specific to natural rubber allergens, and by use of this IgE antibody, the allergens in rubber products and in the air of the workplace. (2) The Division of Allergic Diseases and Internal Medicine reviewed the prevalence and severity of the problem. (3) The Clinical Practice Committee appointed a multidisciplinary task force to implement measures to reduce exposure. The 3 sections of this article describe the Mayo Clinic's experience of successful control of this occupational health problem. Use of only gloves with low or undetectable allergen content greatly reduced the concentration of allergen in the work site, reduced the number of new cases of occupational allergy to rubber, and allowed individuals with latex allergy to work at their usual jobs.
- Published
- 2002
- Full Text
- View/download PDF
5. Removal of bronchoalveolar cells augments the late eosinophilic response to segmental allergen challenge.
- Author
-
Hunt LW, Gleich GJ, Kita H, Weiler DA, Schroeder DR, Vuk-Pavlovic Z, and Sur S
- Subjects
- Adult, Asthma pathology, Bronchial Provocation Tests, Bronchoalveolar Lavage Fluid cytology, Cell Division, Eosinophils pathology, Female, Humans, Leukocyte Count, Lung immunology, Macrophages physiology, Male, Middle Aged, Plant Proteins immunology, Pollen immunology, Time Factors, Antigens immunology, Asthma immunology, Bronchoalveolar Lavage Fluid immunology, Eosinophils immunology
- Abstract
Background: In patients with quiescent asthma, macrophages are the most prevalent cells recovered by bronchoalveolar lavage (BAL). Through activation via their FcepsilonRII receptors or by acting as antigen-presenting cells, macrophages could, in theory, promote the late airway response to allergen., Objective: In order to investigate the importance of macrophages and other airway luminal cells in inducing the late airway response, a novel washout experiment was designed., Methods: Five patients with ragweed-allergic asthma underwent bronchoscopy and segmental bronchial challenge with either normal saline or short ragweed extract in two segments of one lung. In a third segment of the opposite lung, 12 successive BALs (25 mL each) were performed, followed by challenge with an identical dose of short ragweed (washed-challenged segment). After 24 h, all three challenged segments underwent BAL., Results: Initially, in the washed-challenged segment, over 80% (mean 80.4%, range 68-88%) of the recoverable airway dwelling cells were removed. Unexpectedly, 24 h later these same washed-challenged segments contained more eosinophils in the BAL than the challenged segments from the opposite lung (P = 0.033)., Conclusions: Removing the majority of airway luminal cells followed by allergen bronchoprovocation increased the number of eosinophils recovered 24 h after challenge. Our results suggest that in quiescent allergic asthma, the airway luminal cells are protective and attenuate the late eosinophilic response to allergen challenge.
- Published
- 2002
- Full Text
- View/download PDF
6. How to manage difficult asthma cases. An action plan for physicians and patients.
- Author
-
Hunt LW
- Subjects
- Adult, Asthma diagnosis, Asthma drug therapy, Asthma etiology, Child, Glucocorticoids adverse effects, Glucocorticoids therapeutic use, Humans, Patient Compliance, Patient Education as Topic, Asthma therapy, Patient Care Planning
- Abstract
Patients with difficult-to-manage asthma represent one of the greatest challenges in primary care practice. Because these patients are at risk for life-threatening attacks, close monitoring is essential to ensure compliance and to control attacks or medication side effects. In this article, Dr Hunt discusses the many aspects of management, including assessment, identification of triggers, treatment planning, and patient and family education. An "action plan" that outlines the management program is described.
- Published
- 2001
- Full Text
- View/download PDF
7. Prevalence, pathophysiology, and treatment of patients with asthma and gastroesophageal reflux disease.
- Author
-
Alexander JA, Hunt LW, and Patel AM
- Subjects
- Adult, Antacids therapeutic use, Asthma physiopathology, Asthma therapy, Esophagitis, Peptic complications, Esophagitis, Peptic physiopathology, Esophagitis, Peptic therapy, Esophagoscopy, Gastric Acid physiology, Gastroesophageal Reflux drug therapy, Gastroesophageal Reflux physiopathology, Gastroesophageal Reflux surgery, Humans, Hydrogen-Ion Concentration, Monitoring, Ambulatory, Prevalence, Proton Pump Inhibitors, Asthma complications, Gastroesophageal Reflux complications
- Abstract
About one third of the US adult population experiences symptoms of gastroesophageal reflux on a monthly basis. Asthma is present in about 5% of the same population. This article reviews and summarizes the literature in the following areas: (1) prevalence of gastroesophageal reflux disease (GERD) in asthmatic patients based on clinical symptoms, endoscopic esophagitis, and 24-hour ambulatory esophageal pH recordings; (2) proposed pathophysiologic mechanisms linking the 2 diseases; and (3) medical and surgical treatment trial results of antireflux therapy for asthmatic patients. Asthmatic patients appear to have an increased prevalence of GERD symptoms and 24-hour esophageal acid exposure. The clinical management of these patients remains controversial. Common management approaches to GERD in asthmatic patients include medical therapy with a proton pump inhibitor and/or antireflux surgery, which improve asthma symptoms in many patients but minimally affect pulmonary function.
- Published
- 2000
- Full Text
- View/download PDF
8. Latex allergy: a primary care primer.
- Author
-
Mahmoudi M and Hunt LW
- Subjects
- Allied Health Personnel, Humans, Occupational Diseases diagnosis, Occupational Diseases etiology, Occupational Diseases therapy, Latex Hypersensitivity diagnosis, Latex Hypersensitivity etiology, Latex Hypersensitivity therapy
- Abstract
Latex allergy has become an epidemic among healthcare workers. Other individuals who are frequently exposed to latex gloves or products containing latex have experienced latex hypersensitivity, as well. Identification of patients who have latex allergy is crucial to physicians in order to formulate a management plan. This article includes discussion of the basic background on latex preparation, hypersensitivity, occupational risks, and management of affected patients.
- Published
- 2000
9. Nebulized lidocaine in the treatment of severe asthma in children: a pilot study.
- Author
-
Decco ML, Neeno TA, Hunt LW, O'Connell EJ, Yunginger JW, and Sachs MI
- Subjects
- Administration, Inhalation, Adolescent, Adrenocortical Hyperfunction drug therapy, Child, Female, Glucocorticoids adverse effects, Glucocorticoids therapeutic use, Humans, Male, Nebulizers and Vaporizers, Pilot Projects, Asthma drug therapy, Lidocaine administration & dosage
- Abstract
Background: Glucocorticoids have been used to treat asthma since the 1950s; however, their adverse systemic effects have limited their duration of use and dosage. Unfortunately, many patients with severe asthma often require oral glucocorticoids in addition to inhaled glucocorticoids. Alternatives to glucocorticoids have been sought with mixed success. Recently, lidocaine has been added to the list of potent glucocorticoid sparing agents for the treatment of severe asthma., Objective: We report the first group of pediatric patients with severe asthma treated with nebulized lidocaine., Methods: The study was performed in an open manner with 6 severely asthmatic patients followed in the Pediatric Allergy and Immunology Section, Mayo Clinic. The only intervention was the institution of nebulized lidocaine (0.8 mg/kg/dose to 2.5 mg/kg/dose t.i.d to q.i.d). The average daily steroid requirement was followed during the administration of the nebulized lidocaine., Results: During a mean of 11.2 months of therapy (range 7 to 16 months) 5 of the 6 patients completely discontinued their oral glucocorticoids within an average time of 3.4 months (range 1 to 7 months)., Conclusions: After further study, lidocaine may prove to be the first non-toxic, steroid alternative to patients with severe steroid-dependent asthma.
- Published
- 1999
- Full Text
- View/download PDF
10. Simultaneous IgE-mediated urticaria and contact dermatitis from latex.
- Author
-
Mahmoudi M, Dinneen AM, and Hunt LW
- Subjects
- Adult, Aged, Dermatitis, Allergic Contact etiology, Dermatitis, Allergic Contact immunology, Female, Humans, Infant, Latex Hypersensitivity etiology, Latex Hypersensitivity immunology, Male, Middle Aged, Radioallergosorbent Test, Skin Tests, Urticaria chemically induced, Urticaria immunology, Dermatitis, Allergic Contact complications, Immunoglobulin E immunology, Latex adverse effects, Latex Hypersensitivity complications, Urticaria complications
- Published
- 1998
- Full Text
- View/download PDF
11. Safety considerations in treating concomitant diseases in patients with asthma.
- Author
-
Hunt LW
- Subjects
- Adrenergic beta-Antagonists therapeutic use, Anti-Asthmatic Agents therapeutic use, Asthma drug therapy, Bone Diseases complications, Cardiovascular Diseases complications, Eye Diseases complications, Humans, Anti-Inflammatory Agents, Non-Steroidal therapeutic use, Asthma complications, Bone Diseases drug therapy, Cardiovascular Agents therapeutic use, Cardiovascular Diseases drug therapy, Eye Diseases drug therapy
- Abstract
The treatment for asthma usually involves a combination of drugs used for bronchodilation and to treat underlying airway inflammation. When asthma is severe, the regimen used to treat asthma can become quite complicated, often using as many as 3 or 4 separate pharmacological agents. As patients with asthma get older, their medication regimen can become even more complex with the development of numerous other age-related diseases requiring their own list of medications. Diseases of the joints, diseases of the eye, cardiovascular disease, neurological disease and urological problems represent the most common conditions that patients develop, at times needing medications which might interfere with asthma management. Many of these diseases require the use of nonsteroidal anti-inflammatory agents, well known to provoke wheezing in patients with intrinsic asthma, and diseases of the eye and cardiovascular system frequently require use of beta-blockers which can cause or exacerbate asthma. Managing patients with asthma who have other diseases requires constant supervision of their medication usage and careful and cautious review of the entire list of medications at each presentation.
- Published
- 1998
- Full Text
- View/download PDF
12. Lidocaine and its analogues inhibit IL-5-mediated survival and activation of human eosinophils.
- Author
-
Okada S, Hagan JB, Kato M, Bankers-Fulbright JL, Hunt LW, Gleich GJ, and Kita H
- Subjects
- Apoptosis drug effects, Cell Survival drug effects, Dexamethasone pharmacology, Eosinophils cytology, Granulocyte-Macrophage Colony-Stimulating Factor pharmacology, Humans, In Vitro Techniques, Interleukin-3 pharmacology, Superoxides metabolism, Eosinophils drug effects, Eosinophils physiology, Interleukin-5 pharmacology, Lidocaine analogs & derivatives, Lidocaine pharmacology
- Abstract
Eosinophils and cytokines active on eosinophils, especially IL-5, are believed to be critically involved in chronic allergic diseases. IL-5 activates eosinophils and enhances their survival in vitro by delaying apoptosis. In this study, we found that lidocaine and six analogues blunt responses of eosinophils to IL-5. Lidocaine and its derivatives inhibit IL-5-mediated eosinophil survival in a concentration-dependent manner (IC50 = 110 microM for 30 pg/ml IL-5). At suboptimal lidocaine concentrations, the eosinophil survival response to IL-5 shifts and more IL-5 is required to maintain survival. The inhibitory effect requires at least 24-h exposure of eosinophils to lidocaine, and the protein kinase C activator, PMA, completely reverses the inhibition. A multiparameter flow-cytometric analysis shows that lidocaine hastens the apoptosis of eosinophils normally delayed by IL-5. Lidocaine does not affect IL-5R expression or IL-5-induced protein tyrosine phosphorylation. Lidocaine also inhibits eosinophil survival mediated by IL-3 or granulocyte-macrophage CSF, although less potently than that mediated by IL-5. Furthermore, lidocaine inhibits eosinophil superoxide production stimulated by IL-5, granulocyte-macrophage CSF, or IL-3, but not that stimulated by platelet-activating factor, immobilized IgG, or PMA. Lidocaine and its derivatives show novel immunomodulatory properties and are able to blunt eosinophil responses to cytokines in addition to their local anesthetic or antiarrhythmic properties. Thus, lidocaine and its derivatives may represent a new class of therapeutic agents to treat patients with allergic diseases.
- Published
- 1998
13. A medical-center-wide, multidisciplinary approach to the problem of natural rubber latex allergy.
- Author
-
Hunt LW, Boone-Orke JL, Fransway AF, Fremstad CE, Jones RT, Swanson MC, McEvoy MT, Miller LK, Majerus ET, Luker PA, Scheppmann DL, Webb MJ, and Yunginger JW
- Subjects
- Air Pollutants, Occupational analysis, Cost-Benefit Analysis, Dermatitis, Occupational diagnosis, Dermatitis, Occupational etiology, Gloves, Protective economics, Hospitals, Group Practice organization & administration, Humans, Minnesota epidemiology, Particle Size, Risk Factors, Dermatitis, Occupational epidemiology, Disease Outbreaks prevention & control, Gloves, Protective adverse effects, Health Personnel, Latex adverse effects
- Abstract
Latex is a common cause of occupational allergy in health care workers; latex-sensitized patients are at increased risk of allergic reactions in medical environments. Skin test reagents and latex-specific immunoglobulin E immunoassays were established for diagnosis of latex allergy. Inhibition immunoassays were developed for measuring latex aeroallergens and latex allergens in rubber products. A registry of latex-sensitive employees was established. High-allergen gloves were removed from the medical center inventory; latex aeroallergen levels subsequently declined. Despite an increasing number of gloves used annually, expenditures for gloves in 1994 were lower than in previous years. Latex-sensitive individuals can be identified using skin tests or immunoassays. Latex aeroallergen levels in medical environments can be reduced substantially at lower cost by using powder-free rubber gloves with lower allergen content.
- Published
- 1996
- Full Text
- View/download PDF
14. Eosinophil recruitment is associated with IL-5, but not with RANTES, twenty-four hours after allergen challenge.
- Author
-
Sur S, Kita H, Gleich GJ, Chenier TC, and Hunt LW
- Subjects
- Adolescent, Adult, Bronchoalveolar Lavage Fluid chemistry, Bronchoalveolar Lavage Fluid cytology, Cell Degranulation, Chemotaxis, Leukocyte, Female, Humans, Leukocyte Count, Male, Time Factors, Allergens immunology, Asthma immunology, Chemokine CCL5 physiology, Eosinophils immunology, Interleukin-5 physiology
- Abstract
Several lines of evidence suggest that the chemokine RANTES may play a role in eosinophilia observed during allergic inflammation. To test this hypothesis, six patients with allergic asthma were studied. After performing bronchoalveolar lavage in a lung segment (baseline), segmental bronchoprovocation was performed with saline solution in another segment and with ragweed in a third segment. Bronchoalveolar lavage was performed 24 hours later in the saline-challenged (sham) and ragweed-challenged lung segments. The bronchoalveolar lavage fluids from the baseline, sham, and ragweed segments were analyzed for cell counts and for the levels of IL-5, RANTES, and eosinophil-derived neurotoxin. IL-5 levels were elevated in the ragweed (984 +/- 588 pg/ml) compared with sham segments (2.8 +/- 0.2 pg/ml, p = 0.02). Likewise, RANTES levels were elevated in the ragweed (12.93 +/- 3.4 pg/ml) compared with the sham segments (3.05 +/- 1.19 pg/ml, p = 0.006). The IL-5 levels correlated with both eosinophil numbers (r = 0.90, p < 0.02) and eosinophil-derived neurotoxin levels (r = 0.89, p < 0.02). In contrast, RANTES levels did not correlate with either eosinophil numbers or eosinophil-derived neurotoxin levels. These results indicate that although both IL-5 and RANTES are elevated 24 hours after allergen challenge, only IL-5 correlates with eosinophil recruitment and degranulation.
- Published
- 1996
- Full Text
- View/download PDF
15. Cytokine production at the site of disease in chronic eosinophilic pneumonitis.
- Author
-
Kita H, Sur S, Hunt LW, Edell ES, Weiler DA, Swanson MC, Samsel RW, Abrams JS, and Gleich GJ
- Subjects
- Adult, Base Sequence, Bronchoalveolar Lavage Fluid chemistry, Female, Granulocyte-Macrophage Colony-Stimulating Factor, Humans, Interleukin-5 analysis, Interleukin-5 biosynthesis, Molecular Sequence Data, Polymerase Chain Reaction, Pulmonary Eosinophilia metabolism, Cytokines biosynthesis, Pulmonary Eosinophilia physiopathology
- Abstract
Chronic eosinophilic pneumonitis (CEP) is characterized by longstanding respiratory symptoms accompanied by a massive pulmonary eosinophil infiltration. We hypothesized that cytokine(s) produced in the disease sites are implicated in the pathophysiology of CEP. We studied peripheral blood and bronchoalveolar lavage fluids (BALF) obtained from two lung segments of a patient with CEP. Seventy times more eosinophils were found in the BALF from an involved lung segment (showing patchy opacification on a chest roentgenogram) than from an uninvolved segment. The eosinophil-active cytokines interleukin-5 (IL-5), IL-6, and IL-10 were strikingly elevated in the BALF from the involved lung segment, whereas no or minimal levels of these cytokines were detectable in the BALF from the uninvolved segment or serum, respectively. Leukocytes in the involved lung segment, but not those in peripheral blood, expressed messenger ribonucleic acid (mRNA) for IL-5, IL-6, and IL-10. In contrast, IL-2, IL-3, IL-4, interferon-gamma (IFN-gamma), granulocyte-macrophage colony-stimulating factor (GM-CSF), and tumor necrosis factor-alpha (TNF-alpha) were not detected in any sample. These findings suggest that increased production of several cytokines, such as IL-5, IL-6, and IL-10, in the involved lung segment, but not in the uninvolved lung segment or peripheral blood, is a critical pathophysiologic feature of CEP.
- Published
- 1996
- Full Text
- View/download PDF
16. Effect of nebulized lidocaine on severe glucocorticoid-dependent asthma.
- Author
-
Hunt LW, Swedlund HA, and Gleich GJ
- Subjects
- Administration, Inhalation, Adult, Aged, Bronchodilator Agents administration & dosage, Female, Humans, Lidocaine administration & dosage, Male, Middle Aged, Prospective Studies, Respiratory Function Tests, Treatment Outcome, Asthma drug therapy, Bronchodilator Agents therapeutic use, Glucocorticoids therapeutic use, Lidocaine therapeutic use, Prednisone therapeutic use
- Abstract
Objective: To determine whether nebulized lidocaine is a useful therapy in patients with severe glucocorticoid-dependent asthma., Design: We prospectively conducted an open study of the effects of administration of nebulized lidocaine four times daily in 20 patients with asthma who had side effects of exogenous hypercortisolism., Material and Methods: The 18 women and 2 men, who were 19 to 71 years of age, all had severe asthma that necessitated both topical and systemic administration of glucocorticoids to control symptoms of airflow obstruction. Treatment consisted of nebulized lidocaine, 40 to 160 mg four times daily. Initially, all topical and systemic glucocorticoid regimens were maintained; if peak flow rates remained stable and symptoms of asthma were well controlled, orally administered glucocorticoid regimens were slowly reduced., Results: Thirteen patients were able to discontinue oral use of glucocorticoids entirely, despite prolonged glucocorticoid dependence (mean 6.6 years and median 3 years for the 20 patients); 4 achieved reduction in their daily glucocorticoid requirement while maintaining control of symptoms of asthma (duration of glucocorticoid dependence for responders, mean 6.2 years and median 3.2 years). Three patients had no apparent response, as determined by their continued severe asthma symptoms and inability to reduce oral glucocorticoid requirements., Conclusion: These results suggest that nebulized lidocaine is a useful therapy for chronic asthma, allowing reduction or elimination of oral glucocorticoid therapy.
- Published
- 1996
- Full Text
- View/download PDF
17. Allergen challenge in asthma: association of eosinophils and lymphocytes with interleukin-5.
- Author
-
Sur S, Gleich GJ, Offord KP, Swanson MC, Ohnishi T, Martin LB, Wagner JM, Weiler DA, and Hunt LW
- Subjects
- Adolescent, Adult, Blood Proteins analysis, Bronchial Provocation Tests, Bronchoalveolar Lavage, Bronchoalveolar Lavage Fluid chemistry, Bronchoalveolar Lavage Fluid cytology, Bronchoalveolar Lavage Fluid immunology, Bronchoscopy, Eosinophil Granule Proteins, Humans, Immunoradiometric Assay, Inflammation Mediators analysis, Male, Pancreatic Elastase analysis, Radioimmunoassay, Allergens adverse effects, Asthma immunology, Chemotaxis, Leukocyte immunology, Eosinophils immunology, Interleukin-5 immunology, Lymphocytes immunology, Ribonucleases
- Abstract
To test whether eosinophil recruitment after pulmonary allergen challenge is associated with interleukin (IL)-5 in patients with asthma, we performed segmental bronchoprovocation (SBP) with saline, and with low and high dosages of ragweed extract in six patients with allergic asthma. Bronchoalveolar lavage (BAL) of the challenged segments was performed 5 min after challenge (immediate BAL fluid) and repeated 24 h later (late BAL fluid). Allergen challenge resulted in recruitment of eosinophils, and increased levels of eosinophil-active cytokines. A bioassay showed the predominant eosinophil-active cytokine in the late BAL fluids to be IL-5. Analysis of the late BAL fluids revealed that IL-5 levels correlated with the numbers of eosinophils and lymphocytes. This study provides evidence that IL-5 is a critical cytokine associated with eosinophil and lymphocyte recruitment into the airways of patients with asthma following exposure to allergen.
- Published
- 1995
- Full Text
- View/download PDF
18. An epidemic of occupational allergy to latex involving health care workers.
- Author
-
Hunt LW, Fransway AF, Reed CE, Miller LK, Jones RT, Swanson MC, and Yunginger JW
- Subjects
- Anaphylaxis chemically induced, Anaphylaxis epidemiology, Asthma chemically induced, Asthma epidemiology, Conjunctivitis, Allergic chemically induced, Conjunctivitis, Allergic epidemiology, Dermatitis, Contact epidemiology, Female, Gloves, Surgical adverse effects, Humans, Hypersensitivity diagnosis, Hypersensitivity, Immediate diagnosis, Hypersensitivity, Immediate epidemiology, Immunoglobulin E analysis, Latex immunology, Male, Minnesota epidemiology, Occupations, Prospective Studies, Respiratory Hypersensitivity epidemiology, Skin Tests, Urticaria chemically induced, Urticaria epidemiology, Disease Outbreaks, Health Personnel, Hypersensitivity epidemiology, Latex adverse effects, Occupational Diseases epidemiology
- Abstract
IgE-mediated sensitivity to natural rubber latex is being recognized more frequently among health care workers. Between January 1990 and June 1993, we evaluated 342 consecutive Mayo Medical Center employees who reported symptoms suggestive of latex allergy. All were interviewed and underwent puncture skin testing with extracts of rubber gloves. In some cases, latex-specific IgE antibodies were measured by immunoassay. One hundred four of the 342 employees evaluated (30%) were latex-allergic. Risk factors for sensitization included frequent use of disposable gloves, presence of prior atopic disease, and prior or current hand dermatitis. The peak onset of symptoms occurred in late 1989 and early 1990 and did not correlate with a peak in glove usage at our medical center, which continued to rise. Most sensitized employees (78%) reported contact urticaria from rubber gloves, and over two thirds also experienced allergic rhinitis, conjunctivitis, or asthma when working in areas where large numbers of gloves were being used. Sixteen episodes of rubber-induced anaphylaxis were documented in 12 employees; six episodes occurred after latex skin testing and were easily reversed with appropriate therapy. Our findings substantiate a local epidemic of latex allergy among medical center employees. Epidemiologic studies are needed to assess the effects of various interventions to reduce occupational exposure to latex allergens. Although prick skin testing with concentrated latex glove extracts presents some risk of systemic reaction, pending availability of commercial diagnostic extracts, such testing is generally safe when performed by skilled laboratory personnel. Skin testing is warranted to investigate health care workers suspected of being latex-sensitive.
- Published
- 1995
- Full Text
- View/download PDF
19. Anaphylaxis induced by the carboxymethylcellulose component of injectable triamcinolone acetonide suspension (Kenalog).
- Author
-
Patterson DL, Yunginger JW, Dunn WF, Jones RT, and Hunt LW
- Subjects
- Adult, Anaphylaxis immunology, Humans, Immunoglobulin E blood, Male, Skin Tests, Anaphylaxis chemically induced, Carboxymethylcellulose Sodium adverse effects, Triamcinolone Acetonide adverse effects
- Abstract
Background: Allergic reactions to various corticosteroids are rare but have been reported previously., Objective: We wished to determine the etiology of an anaphylactic reaction in a patient who had received intracutaneous Kenalog (triamcinolone acetonide)., Methods: Skin testing and serologic testing for allergen-specific IgE antibodies was performed for triamcinolone acetonide, its individual components, and three other corticosteroid preparations in both the patient and six other nonallergic persons., Results: The patient had positive skin tests to only the carboxymethylcellulose component of triamcinolone acetonide. He had negative skin test reactions to three other steroid preparations which did not contain carboxymethylcellulose. Specific IgE antibodies to carboxymethylcellulose were also elevated by immunoassay and immunoblotting. Control patients had negative skin tests to triamcinolone acetonide, its components, and three other corticosteroid preparations, and their sera lacked significant specific IgE antibodies to these materials., Conclusions: Our results indicate that the triamcinolone acetonide component responsible for the patient's reaction was the suspending agent carboxymethylcellulose. We urge physicians to consider component testing when patients experience allergic-type reactions to drugs.
- Published
- 1995
20. Quantification of occupational latex aeroallergens in a medical center.
- Author
-
Swanson MC, Bubak ME, Hunt LW, Yunginger JW, Warner MA, and Reed CE
- Subjects
- Academic Medical Centers, Air Pollutants, Occupational adverse effects, Air Pollutants, Occupational isolation & purification, Allergens adverse effects, Allergens isolation & purification, Electrophoresis, Polyacrylamide Gel, Gloves, Surgical, Humans, Hypersensitivity etiology, Immunoassay, Immunoblotting, Immunoglobulin E analysis, Latex adverse effects, Latex isolation & purification, Occupational Diseases etiology, Occupational Exposure, Particle Size, Surgicenters, Air Pollutants, Occupational analysis, Air Pollution, Indoor, Allergens analysis, Latex analysis
- Abstract
To determine the quantity, variability, and mean aerodynamic diameter of latex aeroallergens in a large medical center, we collected air samples from work sites by using area and personal breathing zone air samplers, and we measured latex allergens by an inhibition assay with IgE antibodies from latex-sensitive individuals. Latex aeroallergen concentrations in 11 areas where powdered latex gloves were frequently used ranged from 13 to 208 ng/m3, and in areas where powdered latex gloves were never or seldom used, concentrations ranged from 0.3 to 1.8 ng/m3. Installation and use of a laminar flow glove changing station in one work area did not reduce latex aeroallergen levels. Large quantities of allergen were recovered from used laboratory coats and anesthesia scrub suits and from laboratory surfaces. Latex allergen concentrations in personal breathing zone samplers worn by health care workers in areas where powdered gloves were frequently used ranged from 8 to 974 ng/m3. Exposure likely occurs when gloves are changed and as a result of resuspension from reservoirs of powder in the room and clothing. Latex allergens were found in all particle sizes but were predominant in particles greater than 7 microns in mass median aerodynamic diameter. Results of electrophoretic immunoblotting showed that the aeroallergens are primarily the higher molecular mass components of the latex glove proteins. Measures to control exposure can be monitored by both area and personal air sampling with this immunochemical approach. Use of gloves with low allergen content or powder-free gloves appears to be more effective than use of a laminar flow glove changing station in reducing aeroallergen levels.
- Published
- 1994
- Full Text
- View/download PDF
21. Severe asthma complicated by bilateral diaphragmatic paralysis attributed to Parsonage-Turner syndrome.
- Author
-
Patterson DL, DeRemee RA, and Hunt LW
- Subjects
- Asthma physiopathology, Brachial Plexus Neuritis physiopathology, Dyspnea physiopathology, Female, Humans, Middle Aged, Respiratory Function Tests, Respiratory Paralysis physiopathology, Asthma complications, Brachial Plexus Neuritis complications, Dyspnea etiology, Respiratory Paralysis complications
- Abstract
Progressive dyspnea that developed in a 52-year-old woman with a lifelong history of asthma did not respond to high-dose orally administered glucocorticoids. Initially, a diagnosis of allergic bronchopulmonary aspergillosis or hypersensitivity pneumonia was suggested as the cause of the worsening dyspnea. Pulmonary function tests demonstrated severe airway obstruction; substantial improvement was noted after bronchodilator therapy. Maximal inspiratory pressure was decreased, and the diffusing capacity of the lungs was abnormal. Computed tomography of the chest showed no parenchymal or mediastinal abnormalities. During a sniff test, fluoroscopy of her diaphragm disclosed paradoxical motion of both hemidiaphragms during inspiration, consistent with bilateral hemidiaphragmatic paralysis. Parsonage-Turner syndrome was diagnosed. The dose of glucocorticoids was tapered. Follow-up of the patient by telephone contact in March 1994 (9 months after her initial examination at our clinic) revealed that the dyspnea was still severe.
- Published
- 1994
- Full Text
- View/download PDF
22. Endotoxin contamination causes neutrophilia following pulmonary allergen challenge.
- Author
-
Hunt LW, Gleich GJ, Ohnishi T, Weiler DA, Mansfield ES, Kita H, and Sur S
- Subjects
- Adolescent, Adult, Asthma etiology, Bronchoalveolar Lavage Fluid chemistry, Female, Humans, Hypersensitivity diagnosis, Immunoradiometric Assay, Inflammation, Leukocyte Count, Leukocyte Elastase, Limulus Test, Male, Pancreatic Elastase analysis, Skin Tests, Time Factors, Allergens, Asthma diagnosis, Asthma immunology, Bronchial Provocation Tests adverse effects, Bronchoalveolar Lavage Fluid cytology, Drug Contamination, Endotoxins adverse effects, Eosinophils, Hypersensitivity complications, Neutrophils
- Abstract
Segmental bronchoprovocation (SBP) with allergen was used in an attempt to study eosinophils recruited to the airway 24 h after challenge. Unexpectedly, in the first four patients, neutrophils (rather than eosinophils) were recruited in the bronchoalveolar lavage (BAL) fluids, and we hypothesized that the allergen extracts were contaminated with endotoxin. The extracts used for challenge in the first four patients tested positive for bacterial endotoxin in a limulus amebocyte lysate assay. Rechallenge of one patient from the first group with a comparable dose of an endotoxin-free extract and SBP with endotoxin-free extract in five additional patients resulted in preferential recruitment of eosinophils rather than neutrophils. The number of neutrophils recovered from the challenged segments in the patients challenged with endotoxin-free extract was significantly less than that observed in the first four patients. Taken together, these observations suggest that neutrophil recruitment in the 24-h BAL fluids from the first four patients was probably due to endotoxin contamination of the allergen extract. We caution investigators that endotoxin contamination of allergen extract may alter the cellular inflammation during the late airway response following allergen challenge.
- Published
- 1994
- Full Text
- View/download PDF
23. Sudden-onset fatal asthma.
- Author
-
Sur S, Hunt LW, Crotty TB, and Gleich GJ
- Subjects
- Asthma mortality, Humans, Asthma physiopathology
- Published
- 1994
- Full Text
- View/download PDF
24. Extractable latex allergens and proteins in disposable medical gloves and other rubber products.
- Author
-
Yunginger JW, Jones RT, Fransway AF, Kelso JM, Warner MA, and Hunt LW
- Subjects
- Allergens analysis, Allergens immunology, Antibody Specificity, Dermatitis, Allergic Contact immunology, Humans, Immunoassay methods, Immunoglobulin E blood, Plant Proteins analysis, Plant Proteins immunology, Allergens isolation & purification, Gloves, Protective, Latex, Plant Proteins isolation & purification, Rubber
- Abstract
Background: IgE-mediated sensitization to rubber proteins is being reported with increasing frequency in health care workers. To explore the relative importance of various sources of allergen exposure, we measured the total rubber allergen and protein levels in extracts of disposable rubber gloves and compared the allergen levels with those in extracts of other medical and consumer rubber products., Methods: Rubber allergens were measured by inhibition immunoassay with a rubber glove extract as the solid-phase allergen and pooled plasma from five rubber-sensitized health care workers as the IgE antibody source. Proteins were measured by Ninhydrin assay., Results: Among 71 lots of gloves tested, the extractable allergen and protein levels were significantly correlated and were appreciably higher in powdered gloves than in powder-free gloves. Allergen levels varied 3000-fold among gloves from different manufacturers and were higher in examination gloves than in surgical or chemotherapy gloves. Measurable allergen was found in 11 of 24 lots of "hypoallergenic" gloves tested. Allergen levels in toy balloons were comparable to those in powdered gloves; much lower allergen levels were measured in condoms and anesthesia rebreathing bags., Conclusions: The allergen content of disposable rubber gloves varies widely and is higher in powdered gloves than in powder-free gloves and higher in examination gloves than in surgical gloves. Hypoallergenic gloves may contain substantial amounts of IgE-binding proteins. Gloves and toy balloons appear to be more important sources of rubber allergens than the other rubber products tested.
- Published
- 1994
- Full Text
- View/download PDF
25. The epidemiology of latex allergy in health care workers.
- Author
-
Hunt LW
- Subjects
- Dermatitis, Allergic Contact immunology, Humans, Immunoglobulin E, Risk Factors, Skin Tests, Dermatitis, Allergic Contact epidemiology, Health Personnel, Protective Clothing adverse effects, Rubber adverse effects
- Published
- 1993
26. Sudden-onset fatal asthma. A distinct entity with few eosinophils and relatively more neutrophils in the airway submucosa?
- Author
-
Sur S, Crotty TB, Kephart GM, Hyma BA, Colby TV, Reed CE, Hunt LW, and Gleich GJ
- Subjects
- Aged, Asthma etiology, Asthma metabolism, Asthma mortality, Blood Proteins metabolism, Bronchi metabolism, Eosinophil Granule Proteins, Eosinophils metabolism, Female, Fluorescent Antibody Technique, Humans, Leukocyte Count, Male, Middle Aged, Mucous Membrane metabolism, Mucous Membrane pathology, Neutrophils metabolism, Pancreatic Elastase metabolism, Asthma pathology, Bronchi pathology, Eosinophils pathology, Neutrophils pathology, Ribonucleases
- Abstract
To determine the histologic differences in the airways of patients who died from sudden-onset asthma and the more common slow-onset asthma, we studied seven cases of fatal asthma. The numbers of eosinophils and neutrophils, as well as extracellular deposition of their respective granule contents in the airway mucosa and submucosa, were determined and statistically analyzed. Four of the seven patients had slow-onset asthma attacks in which the time interval between onset of asthma and death was more than 2.5 h. In contrast, three patients had sudden-onset asthma in which the time interval between onset of asthma attack and death was less than 1 h. The four patients with slow-onset fatal asthma had more eosinophils (34.1 +/- 6.3 in slow-onset; 9.7 +/- 3.5 in sudden-onset; p = 0.002) and fewer neutrophils (4.8 +/- 2.0 in slow-onset; 16.8 +/- 5.4 in sudden-onset; p = 0.008) in the airway submucosa than did patients with sudden-onset fatal asthma. In addition, within the slow-onset fatal asthma group, eosinophils exceeded neutrophils in the airway submucosa (eosinophils > neutrophils, p = 0.002). By contrast, within the sudden-onset fatal asthma group, neutrophils exceeded eosinophils (neutrophils > eosinophils, p = 0.04). We suggest that sudden-onset fatal asthma is immunohistologically distinct from slow-onset fatal asthma and that it is characterized by a relative paucity of eosinophils in the face of an excess of neutrophils in the airway submucosa.(ABSTRACT TRUNCATED AT 250 WORDS)
- Published
- 1993
- Full Text
- View/download PDF
27. Accuracy of the death certificate in a population-based study of asthmatic patients.
- Author
-
Hunt LW Jr, Silverstein MD, Reed CE, O'Connell EJ, O'Fallon WM, and Yunginger JW
- Subjects
- Adolescent, Adult, Aged, Aged, 80 and over, Asthma diagnosis, Cause of Death, Child, Child, Preschool, Cohort Studies, Female, Humans, Infant, Male, Medical Records statistics & numerical data, Middle Aged, Minnesota epidemiology, Quality Control, Sensitivity and Specificity, Asthma mortality, Death Certificates
- Abstract
Objective: To quantify the reliability of death certificate data concerning asthma., Design: The complete medical records of decedents were reviewed by a physician certified in allergy and pulmonology who determined the cause of death without having access to the original death certificate. Disagreements between the death certificate and the reviewer were adjudicated by an expert panel., Setting: The community of Rochester, Minn., Patients: The mortality cohort included 339 deaths from a larger cohort of 5241 Rochester residents who received medical treatment for asthma between 1964 and 1983., Main Outcome Measures: Kappa coefficients were used to measure agreement beyond that expected by chance between the reviewer and the death certificate. The sensitivity and specificity of the death certificate diagnosis of asthma were calculated against the standard of the reviewer/panel diagnosis., Results: Death certificates reported asthma as an immediate or underlying cause of death in 22 instances (6%), whereas the reviewer/panel identified asthma in 53 cases (16%). In four cases, the death certificate listed asthma and the panel identified another cause of death. The death certificate had a sensitivity of 42% and a specificity of 99% compared with the reviewer/panel. Agreement between death certificates and the reviewer was not influenced by whether an autopsy was performed., Conclusions: Death certificate diagnosis of asthma as an underlying cause of death had a low sensitivity but a high specificity. Increases in mortality due to asthma are not likely caused by false-positive diagnoses of asthma as an underlying cause of death. Asthma mortality rates, determined from death certificate data, may indeed underestimate actual asthma-related mortality.
- Published
- 1993
28. Allergic reactions to latex among health-care workers.
- Author
-
Bubak ME, Reed CE, Fransway AF, Yunginger JW, Jones RT, Carlson CA, and Hunt LW
- Subjects
- Dermatitis, Occupational immunology, Female, Humans, Male, Occupational Diseases immunology, Skin Diseases immunology, Skin Tests, Asthma chemically induced, Conjunctivitis, Allergic chemically induced, Dermatitis, Occupational etiology, Health Personnel, Occupational Diseases chemically induced, Rhinitis, Allergic, Perennial chemically induced, Rubber adverse effects, Skin Diseases chemically induced
- Abstract
With the emergence of the acquired immunodeficiency syndrome (AIDS) epidemic and the practice of protecting health-care workers from all body fluids, the use of rubber gloves has increased, as has occupational allergy to latex among health-care workers. During 1991, 49 Mayo Medical Center employees sought assessment and treatment of rhinitis, conjunctivitis, contact urticaria, contact dermatitis, asthma, or eczema thought to be related to exposure to latex. Most of these persons had a history of atopy and worked in areas where rubber gloves were used and changed frequently. Of the 49 subjects, 34 had positive results of skin tests to latex products, and the sera from 19 of 35 persons tested contained increased latex-specific IgE antibodies. Employees with sensitivity to latex (and co-workers in the immediate areas) should use vinyl gloves and should notify their own health-care providers of their sensitization. Changes in job assignment may be necessary for some persons.
- Published
- 1992
- Full Text
- View/download PDF
29. Immunofluorescent staining for mast cells in idiopathic pulmonary fibrosis: quantification and evidence for extracellular release of mast cell tryptase.
- Author
-
Hunt LW, Colby TV, Weiler DA, Sur S, and Butterfield JH
- Subjects
- Biopsy, Case-Control Studies, Cell Count, Cell Line, Chymases, Fluorescent Antibody Technique, Humans, Lung cytology, Lung pathology, Mast Cells pathology, Pulmonary Fibrosis pathology, Tryptases, Lung immunology, Mast Cells enzymology, Pulmonary Fibrosis immunology, Serine Endopeptidases metabolism
- Abstract
In many diseases, retrospective analysis for determining the presence of mast cells has been difficult because of their loss of metachromatic staining properties once tissue has undergone formalin fixation. We quantified mast cells in peribronchiolar tissue of idiopathic pulmonary fibrosis (IPF) and in normal human lung by using rabbit antiserum to human mast cell tryptase. In lung biopsy specimens from 15 patients with IPF, the mean number of mast cells per high-power field in connective tissue directly adjacent to the lumen of small airways (0.5 to 2 mm in diameter) and other fibrotic foci was 29.9 +/- 10.8 in comparison with 13.7 +/- 3.5 in 16 normal controls (P < 0.001). In addition, mast cells in cases of IPF had an altered appearance--irregularity of the plasma membrane and release of extracellular tryptase. We conclude that the number of mast cells is increased in IPF and that the altered appearance of the mast cells suggests that they are activated and undergoing degranulation.
- Published
- 1992
- Full Text
- View/download PDF
30. Asthma-producing drugs.
- Author
-
Hunt LW and Rosenow EC 3rd
- Subjects
- Aspirin adverse effects, Humans, Asthma chemically induced, Drug Hypersensitivity complications
- Published
- 1992
31. The emergency visit and management of asthma.
- Author
-
Reed CE and Hunt LW
- Subjects
- Emergencies, Humans, Asthma therapy
- Published
- 1990
- Full Text
- View/download PDF
32. Purification of tryptase from a human mast cell line.
- Author
-
Butterfield JH, Weiler DA, Hunt LW, Wynn SR, and Roche PC
- Subjects
- Amino Acid Chloromethyl Ketones pharmacology, Amino Acid Sequence, Amino Acids analysis, Animals, Cell Line, Chromatography, High Pressure Liquid, Electrophoresis, Polyacrylamide Gel, Fluorescent Antibody Technique, Glycerol pharmacology, Humans, Hydrogen-Ion Concentration, Leukemia, Mast-Cell enzymology, Leukemia, Mast-Cell pathology, Leukemia, Mast-Cell physiopathology, Mast Cells drug effects, Mast Cells pathology, Mastocytosis enzymology, Mastocytosis pathology, Mastocytosis physiopathology, Mercuric Chloride pharmacology, Mice, Mice, Nude, Molecular Sequence Data, Peptide Hydrolases analysis, Skin cytology, Dansyl Compounds, Mast Cells enzymology, Peptide Hydrolases isolation & purification
- Abstract
The neutral protease tryptase has been isolated from a human mast cell line, HMC-1. The HMC-1 line was established from the peripheral blood of a patient with mast cell leukemia and maintained as continuously proliferating clones in vitro and as solid mast cell tumors in nude mice. HMC-1-derived tryptase was purified by sequential chromatography on Dowex 1, DEAE 5 PW, and heparin-agarose. Purified tryptase has an apparent molecular weight of 150,000, as determined by molecular sieve HPLC, but migrates as a doublet of bands of 32/35,000 on SDS-PAGE gels. Maximal enzymatic activity was observed at pH 8.5. Cleavage of tosyl-L-arginine methyl ester by purified tryptase was inhibited by dansyl-L-glutamyl-glycyl-L-arginine chloromethyl ketone 2 HCl, HgCl2, tosyl-L-lysine chloromethyl ketone, leupeptin, and PMSF but not by benzamidine, aprotinin, tosyl-L-phenyl-alanine chloromethyl ketone, soybean trypsin inhibitor, human plasma, ovomucoid inhibitor, or lima bean trypsin inhibitor. Microsequencing of purified tryptase yielded an amino terminal sequence that was identical to that previously reported for human pituitary-derived tryptase.
- Published
- 1990
- Full Text
- View/download PDF
33. Frank's story.
- Author
-
Halligan F and Hunt LW
- Subjects
- Cerebrovascular Disorders complications, Cerebrovascular Disorders rehabilitation, Dysarthria etiology, Dysarthria therapy, Humans, Male, Cerebrovascular Disorders nursing
- Published
- 1979
34. Pre-discharge ward: a step nearer home.
- Author
-
Hunt LW, Zinovieff A, and Newell DJ
- Subjects
- England, Evaluation Studies as Topic, Humans, Progressive Patient Care
- Published
- 1967
35. The pre-discharge ward.
- Author
-
Newell DJ, Zinovieff A, and Hunt LW
- Subjects
- Humans, United Kingdom, Hospital Design and Construction
- Published
- 1966
Catalog
Discovery Service for Jio Institute Digital Library
For full access to our library's resources, please sign in.