25 results on '"Jill Odabashian"'
Search Results
2. Left ventricular diastolic dysfunction in lone atrial fibrillation determined by doppler tissue imaging of mitral annular motion
- Author
-
Maran Thamilarasan, Mina K. Chung, Deborah A. Agler, L. Leonardo Rodriguez, James D. Thomas, Richard A. Grimm, Jing Ping Sun, Jill Odabashian, Annitta Morehead, and Allan L. Klein
- Subjects
Adult ,Male ,medicine.medical_specialty ,Heart disease ,medicine.medical_treatment ,Population ,Diastole ,Cardioversion ,Sensitivity and Specificity ,Ventricular Dysfunction, Left ,Reference Values ,Internal medicine ,Mitral valve ,Atrial Fibrillation ,medicine ,Humans ,cardiovascular diseases ,education ,Aged ,Doppler tissue imaging ,education.field_of_study ,business.industry ,P wave ,Atrial fibrillation ,Middle Aged ,medicine.disease ,Myocardial Contraction ,medicine.anatomical_structure ,Ultrasonography, Doppler, Pulsed ,cardiovascular system ,Cardiology ,Mitral Valve ,Female ,Cardiology and Cardiovascular Medicine ,business - Abstract
Despite the prevalence of atrial fibrillation (AF), estimated at 0.9% of the population,1 and the extensive investigation into its pathophysiology, the relative contribution of structural and electrophysiologic processes in the initiation of AF remain to be fully elucidated. Historically, the assessment of atrial function has been problematic. Mitral annular excursion has been used as an index of atrial function, both in baseline conditions and after cardioversion from AF.2‐ 4 Doppler tissue imaging (DTI) allows for the rapid assessment of mitral annular excursion velocities and hence adds to the assessment of atrial contractile function, as well as being a useful parameter in the interrogation of ventricular diastolic function. 5,6 This study examines whether patients with lone AF exhibit abnormalities in atrial function or ventricular filling using 2-dimensional, pulsed-wave Doppler and DTI indexes of atrial contractile and ventricular diastolic function. ••• We studied 24 patients with paroxysmal lone AF and
- Published
- 2000
3. Validation of real-time three-dimensional echocardiography for quantifying left ventricular volumes in the presence of a left ventricular aneurysm: in vitro and in vivo studies
- Author
-
Richard D. White, Jing Ping Sun, Michael Jones, Neil L. Greenberg, Arthur D. Zetts, Michael S. Firstenberg, Jian Xin Qin, Pankaj Gupta, Lisa A. Cardon, Takahiro Shiota, Yong Xu, Scott D. Flamm, Hiroyuki Tsujino, Jill Odabashian, James D. Thomas, and Julio A. Panza
- Subjects
Male ,medicine.medical_specialty ,Heart disease ,Echocardiography, Three-Dimensional ,Hemodynamics ,Ventricular Function, Left ,Aneurysm ,In vivo ,Computer Systems ,medicine ,Animals ,Humans ,cardiovascular diseases ,Heart Aneurysm ,Stroke ,Sheep ,medicine.diagnostic_test ,business.industry ,Phantoms, Imaging ,Magnetic resonance imaging ,Stroke Volume ,Stroke volume ,Middle Aged ,medicine.disease ,Magnetic Resonance Imaging ,Surgery ,Left Ventricular Aneurysm ,Female ,Nuclear medicine ,business ,Cardiology and Cardiovascular Medicine - Abstract
OBJECTIVES: To validate the accuracy of real-time three-dimensional echocardiography (RT3DE) for quantifying aneurysmal left ventricular (LV) volumes. BACKGROUND: Conventional two-dimensional echocardiography (2DE) has limitations when applied for quantification of LV volumes in patients with LV aneurysms. METHODS: Seven aneurysmal balloons, 15 sheep (5 with chronic LV aneurysms and 10 without LV aneurysms) during 60 different hemodynamic conditions and 29 patients (13 with chronic LV aneurysms and 16 with normal LV) underwent RT3DE and 2DE. Electromagnetic flow meters and magnetic resonance imaging (MRI) served as reference standards in the animals and in the patients, respectively. Rotated apical six-plane method with multiplanar Simpson's rule and apical biplane Simpson's rule were used to determine LV volumes by RT3DE and 2DE, respectively. RESULTS: Both RT3DE and 2DE correlated well with actual volumes for aneurysmal balloons. However, a significantly smaller mean difference (MD) was found between RT3DE and actual volumes (-7 ml for RT3DE vs. 22 ml for 2DE, p = 0.0002). Excellent correlation and agreement between RT3DE and electromagnetic flow meters for LV stroke volumes for animals with aneurysms were observed, while 2DE showed lesser correlation and agreement (r = 0.97, MD = -1.0 ml vs. r = 0.76, MD = 4.4 ml). In patients with LV aneurysms, better correlation and agreement between RT3DE and MRI for LV volumes were obtained (r = 0.99, MD = -28 ml) than between 2DE and MRI (r = 0.91, MD = -49 ml). CONCLUSIONS: For geometrically asymmetric LVs associated with ventricular aneurysms, RT3DE can accurately quantify LV volumes.
- Published
- 2000
- Full Text
- View/download PDF
4. Performing an Echocardiographic Examination with a Contrast Agent: A Series on Contrast Echocardiography, Article 2
- Author
-
Jill Odabashian, Susan Floer, Susan Jasper, Alan D. Waggoner, Marti Trough, Sandy Witt, Dennis Carney, Vicky Moore, Sally Moos, David H. Adams, Jim Bednarz, Pam Burgess, Eric Sisk, and Cris Gresser
- Subjects
medicine.medical_specialty ,Cardiotonic Agents ,business.industry ,Contrast Media ,Contrast (music) ,Image Enhancement ,Echocardiography, Doppler ,Echocardiography ,Dobutamine ,Contrast echocardiography ,Exercise Test ,medicine ,Humans ,Radiology, Nuclear Medicine and imaging ,Radiology ,Cardiology and Cardiovascular Medicine ,business - Published
- 2000
5. Comparison by real-time three-dimensional echocardiography of left ventricular geometry in hypertrophic cardiomyopathy versus secondary left ventricular hypertrophy
- Author
-
Fatih Yalçin, Neil L. Greenberg, Harry M. Lever, James D. Thomas, Takahiro Shiota, Mario J. Garcia, Jill Odabashian, and Debbie A. Agler
- Subjects
Adult ,medicine.medical_specialty ,Ejection fraction ,Systole ,business.industry ,Echocardiography, Three-Dimensional ,Hypertrophic cardiomyopathy ,Warfarin ,Concentric hypertrophy ,Thromboembolic stroke ,Cardiomyopathy, Hypertrophic ,Middle Aged ,medicine.disease ,Left ventricular hypertrophy ,Internal medicine ,medicine ,Cardiology ,Humans ,Hypertrophy, Left Ventricular ,cardiovascular diseases ,Cardiology and Cardiovascular Medicine ,business ,Stroke ,medicine.drug - Abstract
The data from the present nonrandomized observational study of 350 older persons with chronic atrial fibrillation showed that compared with aspirin, warfarin administered in a dose to maintain an INR between 2.0 and 3.0 caused a 40% significant reduction in thromboembolic stroke in persons with prior stroke, a 31% significant decrease in thromboembolic stroke in persons with no prior stroke, a 45% significant reduction in thromboembolic stroke in persons with abnormal LV ejection fraction, and a 36% significant decrease in thromboembolic stroke in persons with normal LV ejection fraction. Cox regression analysis showed that the use of warfarin in this study was a significant independent risk factor for reducing new thromboembolic stroke by 67%.
- Published
- 2000
6. Incorporating Ultrasound Contrast in the Laboratory: A Series on Contrast Echocardiography, Article 1
- Author
-
Jim Bednarz, Eric Sisk, Susan Floer, David H. Adams, Susan Jasper, Pam Burgess, Alan D. Waggoner, Cris Gresser, Marti Trough, Vickie Moore, Dennis Carney, Sandy Witt, Jill Odabashian, and Sally Moos
- Subjects
medicine.medical_specialty ,business.industry ,Ultrasound ,Contrast Media ,Contrast (music) ,Drug Costs ,Echocardiography ,Contrast echocardiography ,Injections, Intravenous ,medicine ,Humans ,Radiology, Nuclear Medicine and imaging ,Radiology ,Cardiology and Cardiovascular Medicine ,business - Published
- 2000
7. Color M-mode Doppler flow propagation velocity is a preload insensitive index of left ventricular relaxation: animal and human validation
- Author
-
Michael L. Main, Nicholas G. Smedira, Mario J. Garcia, James D. Thomas, Neil Greenberg, Jill Odabashian, and Michael S. Firstenberg
- Subjects
Male ,medicine.medical_specialty ,Lusitropy ,Heart Valve Diseases ,Diastole ,Blood Pressure ,Coronary Disease ,Blood volume ,Ventricular Function, Left ,symbols.namesake ,Dogs ,Reference Values ,Internal medicine ,Occlusion ,Image Processing, Computer-Assisted ,medicine ,Animals ,Humans ,Aged ,Blood Volume ,business.industry ,Blood flow ,Middle Aged ,Myocardial Contraction ,Echocardiography, Doppler, Color ,Preload ,Flow velocity ,cardiovascular system ,symbols ,Cardiology ,Female ,Cardiology and Cardiovascular Medicine ,business ,Doppler effect ,Blood Flow Velocity - Abstract
OBJECTIVES: To determine the effect of preload in color M-mode Doppler flow propagation velocity (v(p)). BACKGROUND: The interpretation of Doppler filling patterns is limited by confounding effects of left ventricular (LV) relaxation and preload. Color M-mode v(p) has been proposed as a new index of LV relaxation. METHODS: We studied four dogs before and during inferior caval (IVC) occlusion at five different inotropic stages and 14 patients before and during partial cardiopulmonary bypass. Left ventricular (LV) end-diastolic volumes (LV-EDV), the time constant of isovolumic relaxation (tau), left atrial (LA) pre-A and LV end-diastolic pressures (LV-EDP) were measured. Peak velocity during early filling (E) and v(p) were extracted by digital analysis of color M-mode Doppler images. RESULTS: In both animals and humans, LV-EDV and LV-EDP decreased significantly from baseline to IVC occlusion (both p < 0.001). Peak early filling (E) velocity decreased in animals from 56 +/- 21 to 42 +/- 17 cm/s (p < 0.001) without change in v(p) (from 35 +/- 15 to 35 +/- 16, p = 0.99). Results were similar in humans (from 69 +/- 15 to 53 +/- 22 cm/s, p < 0.001, and 37 +/- 12 to 34 +/- 16, p = 0.30). In both species, there was a strong correlation between LV relaxation (tau) and v(p) (r = 0.78, p < 0.001, r = 0.86, p < 0.001). CONCLUSIONS: Our results indicate that color M-mode Doppler v(p) is not affected by preload alterations and confirms that LV relaxation is its main physiologic determinant in both animals during varying lusitropic conditions and in humans with heart disease.
- Published
- 2000
8. An open-source universal strain software platform for monitoring left ventricular systolic function in astronauts on the International Space Station
- Author
-
Mohammed Kassemi, Jagir R. Hussan, Zoran B. Popović, Shafkat Anwar, Jill Odabashian, Patrick Gladding, Peter Hunter, Benjamin D. Levine, James D. Thomas, and Kazuaki Negishi
- Subjects
Pulmonary and Respiratory Medicine ,Open source ,Software ,Strain (chemistry) ,business.industry ,International Space Station ,Medicine ,Systolic function ,Cardiology and Cardiovascular Medicine ,business ,Simulation - Published
- 2015
9. Contrast echocardiographic digital analysis using HDI Lab
- Author
-
Wael A. Jaber, S.E. Vaughn, Jill Odabashian, David L. Prior, Lisa A. Cardon, and James D. Thomas
- Subjects
medicine.medical_specialty ,business.industry ,Contrast effect ,Ultrasound ,Echogenicity ,Beat (acoustics) ,medicine.disease ,Coronary artery disease ,Digital image ,Microbubbles ,Medicine ,Radiology ,business ,Perfusion ,Biomedical engineering - Abstract
Echocardiographic image interpretation is predominantly a subjective process, generally performed using the 'eyeball' technique and thus critically dependent on the reviewer's experience. In the past, software packages for digital image analysis have been limited. Recently, Advanced Technology Laboratories (ATL) has introduced HDI Lab for the analysis of digital images from the ATL HDI 5000 CV ultrasound machine. The purpose of this study was to apply HDI Lab to characterize the normal patterns of echocardiographic contrast uptake into the myocardium. Only by understanding the spatial variation in contrast uptake with normal perfusion can this technique be applied to patients with coronary artery disease. Digital images were obtained from 7 normal volunteers pre and post injection of Optison, microbubbles of albumin containing perfluorocarbon gas. Apical 4 and 2 chamber images were obtained in pulse-inversion harmonic mode, gated to end-diastole of every fourth beat, and stored to either a 3.5" magneto-optical disk (MOD) on the echo machine or to a remote PC via a network connection. Images were stored in a polar format containing data from individual scan lines and echo density quantified from regions of interest in the basal, mid and apical regions of the inferior, septal, anterior and lateral walls. Multifactorial analysis of variance demonstrated highly significant (p
- Published
- 2002
10. Prevalence of left ventricular diastolic dysfunction by Doppler echocardiography: clinical application of the Canadian consensus guidelines
- Author
-
Hirotsugu Yamada, Allan L. Klein, Jing Ping Sun, Ping Ping Goh, Jill Odabashian, Mario J. Garcia, and James D. Thomas
- Subjects
Adult ,Male ,medicine.medical_specialty ,Canada ,Consensus ,Diastole ,Doppler echocardiography ,Severity of Illness Index ,Ventricular Dysfunction, Left ,Internal medicine ,medicine ,Prevalence ,Humans ,Radiology, Nuclear Medicine and imaging ,Aged ,Ohio ,Retrospective Studies ,Aged, 80 and over ,Heart Failure ,Ejection fraction ,E/A ratio ,medicine.diagnostic_test ,business.industry ,Diastolic heart failure ,Age Factors ,Stroke Volume ,Middle Aged ,medicine.disease ,Hypertensive heart disease ,Echocardiography, Doppler ,Heart failure ,Cardiology ,Female ,Cardiology and Cardiovascular Medicine ,business ,Lower limbs venous ultrasonography ,Blood Flow Velocity - Abstract
We evaluated diastolic filling patterns using Doppler echocardiography in 520 consecutive patients referred to our laboratory for transthoracic echocardiograms retrospectively and applied the standard guidelines used to characterize left ventricular (LV) diastolic function. Patients were classified by the Canadian consensus guidelines using transmitral and pulmonary venous Doppler echocardiographic parameters to have normal diastolic function or mild (abnormal relaxation), mild-to-moderate, moderate (pseudonormal), or severe (restrictive) diastolic dysfunction. LV diastolic dysfunction was present in 290 (56%) patients, whereas 167 (45%) patients with a normal LV ejection fraction had abnormal diastolic function. Patients with progressively more abnormal diastolic patterns had greater structural abnormalities with larger left atrial and LV size and lower LV ejection fractions. In the subset of patients with clinical evidence of congestive heart failure (99 patients), the prevalence of primary diastolic heart failure was 38% and most patients had underlying coronary or hypertensive heart disease. Standard guidelines of Doppler echocardiographic parameters allow semiquantitation of diastolic function and can be applied to studying large number of patients in a large clinical practice. (J Am Soc Echocardiogr 2002;15:1237-44.)
- Published
- 2002
11. Myocardial contrast echocardiography: a series on contrast echocardiography, Article 5
- Author
-
Marti McCulloch, Alan D. Waggoner, Sally Moos, Sandra A. Witt, Vickie Moore, Cris Gresser, David H. Adams, Eric Sisk, Pam Burgess, Jill Odabashian, Dennis Carney, Jim Bednarz, and Susan Jasper
- Subjects
medicine.medical_specialty ,business.industry ,media_common.quotation_subject ,Myocardial Ischemia ,Contrast Media ,Endocardial border ,Sensitivity and Specificity ,Myocardial contrast echocardiography ,Coronary arteries ,medicine.anatomical_structure ,Echocardiography ,Contrast echocardiography ,Internal medicine ,Coronary Circulation ,medicine ,Cardiology ,Microbubbles ,Contrast (vision) ,Humans ,Radiology, Nuclear Medicine and imaging ,Cardiology and Cardiovascular Medicine ,Vein ,business ,Perfusion ,media_common - Abstract
This series on contrast echocardiography has previously discussed the value of this technique for the improvement of endocardial border definition in technically challenging patients. The echocardiographic assessment of left ventricular (LV) regional performance can be significantly improved by using LV opacification (LVO) produced by the injection of contrast microbubbles into a peripheral vein. On the basis of years of investigational work, it is now apparent that myocardial contrast echocardiography (MCE) may offer an additional clinical benefit by assessing regional myocardial perfusion. Investigators have recently presented encouraging results using echocardiographic contrast agents for the assessment of myocardial perfusion under optimal imaging conditions. In this final article of the series on contrast, we will provide some basic information on the use of MCE for the assessment of myocardial perfusion. As always, we refer you to more detailed explanations in the listed references. Currently, nuclear imaging that uses thallium or sestamibi scintigraphy is the only clinical technique used to assess myocardial perfusion. In comparison, MCE is less expensive, portable, and does not use ionizing radiation. MCE uses an intravascular tracer and demonstrates better spatial resolution. Contrast microbubbles injected into a peripheral vein, the aortic root, or directly into the coronary arteries are designed to travel through the cardiovascular circulation in a manner similar to red blood cells. These microbubbles not only fill the LV cavity as see during LVO, but they also traverse the epicardial coronary vessels into the myocardial capillaries. The concentration of microbubbles in the myocardial capillary bed is far less than found within the LV cavity after an intravenous injection, so specialized techniques have been developed to detect contrast microbubbles for the assessment of myocardial perfusion. These techniques and the clinical benefits of assessing myocardial perfusion will be discussed in more detail.
- Published
- 2002
12. Contrast and harmonic imaging improves accuracy and efficiency of novice readers for dobutamine stress echocardiography
- Author
-
Steve S. Lin, Jeanne K. Drinko, Jill Odabashian, Irmien Vlassak, Annitta Morehead, David L. Prior, Craig R. Asher, David N. Rubin, Mario J. Garcia, Lisa M. King, James D. Thomas, and Allan L. Klein
- Subjects
Male ,medicine.medical_specialty ,Dobutamine stress echocardiography ,Image quality ,media_common.quotation_subject ,Second-harmonic imaging microscopy ,Contrast Media ,Coronary Disease ,Coronary artery disease ,Internal medicine ,Medicine ,Contrast (vision) ,Humans ,Radiology, Nuclear Medicine and imaging ,Prospective Studies ,media_common ,Aged ,Observer Variation ,business.industry ,medicine.disease ,Echocardiography ,Harmonic ,Cardiology ,Dobutamine ,Female ,Bolus (digestion) ,Cardiology and Cardiovascular Medicine ,business ,medicine.drug ,Echocardiography, Stress - Abstract
Background: Newer contrast agents as well as tissue harmonic imaging enhance left ventricular (LV) endocardial border delineation, and therefore, improve LV wall-motion analysis. Interpretation of dobutamine stress echocardiography is observer-dependent and requires experience. This study was performed to evaluate whether these new imaging modalities would improve endocardial visualization and enhance accuracy and efficiency of the inexperienced reader interpreting dobutamine stress echocardiography. Methods and Results: Twenty-nine consecutive patients with known or suspected coronary artery disease underwent dobutamine stress echocardiography. Both fundamental (2.5 MHZ) and harmonic (1.7 and 3.5 MHZ) mode images were obtained in four standard views at rest and at peak stress during a standard dobutamine infusion stress protocol. Following the noncontrast images, Optison was administered intravenously in bolus (0.5–3.0 ml), and fundamental and harmonic images were obtained. The dobutamine echocardiography studies were reviewed by one experienced and one inexperienced echocardiographer. LV segments were graded for image quality and function. Time for interpretation also was recorded. Contrast with harmonic imaging improved the diagnostic concordance of the novice reader to the expert reader by 7.1%, 7.5%, and 12.6% (P < 0.001) as compared with harmonic imaging, fundamental imaging, and fundamental imaging with contrast, respectively. For the novice reader, reading time was reduced by 47%, 55%, and 58% (P < 0.005) as compared with the time needed for fundamental, fundamental contrast, and harmonic modes, respectively. With harmonic imaging, the image quality score was 4.6% higher (P < 0.001) than for fundamental imaging. Image quality scores were not significantly different for noncontrast and contrast images. Conclusion: Harmonic imaging with contrast significantly improves the accuracy and efficiency of the novice dobutamine stress echocardiography reader. The use of harmonic imaging reduces the frequency of nondiagnostic wall segments.
- Published
- 2002
13. New digital measurement methods for left ventricular volume using real-time three-dimensional echocardiography: comparison with electromagnetic flow method and magnetic resonance imaging
- Author
-
Lisa A. Cardon, Richard D. White, Jianxin Qin, Julio A. Panza, Hiroyuki Tsujino, Arthur D. Zetts, Michael Jones, Jing Ping Sun, Jill Odabashian, Takahiro Shiota, Neil L. Greenberg, James D. Thomas, Scott D. Flamm, and Michael S. Firstenberg
- Subjects
Adult ,Male ,Apical long axis ,medicine.medical_specialty ,Electromagnetics ,Diastole ,Echocardiography, Three-Dimensional ,Biplane ,Ventricular Function, Left ,Computer Systems ,medicine ,Image Processing, Computer-Assisted ,Animals ,Humans ,Radiology, Nuclear Medicine and imaging ,Aged ,Observer Variation ,Measurement method ,Sheep ,medicine.diagnostic_test ,business.industry ,Magnetic resonance imaging ,Stroke Volume ,General Medicine ,Stroke volume ,Blood flow ,Middle Aged ,Magnetic Resonance Imaging ,Feasibility Studies ,Female ,Radiology ,Cardiology and Cardiovascular Medicine ,business ,Nuclear medicine ,Rheology ,Electromagnetic Phenomena ,Blood Flow Velocity - Abstract
AIM: The aim of this study was to investigate the feasibility and accuracy of using symmetrically rotated apical long axis planes for the determination of left ventricular (LV) volumes with real-time three-dimensional echocardiography (3DE). METHODS AND RESULTS: Real-time 3DE was performed in six sheep during 24 haemodynamic conditions with electromagnetic flow measurements (EM), and in 29 patients with magnetic resonance imaging measurements (MRI). LV volumes were calculated by Simpson's rule with five 3DE methods (i.e. apical biplane, four-plane, six-plane, nine-plane (in which the angle between each long axis plane was 90 degrees, 45 degrees, 30 degrees or 20 degrees, respectively) and standard short axis views (SAX)). Real-time 3DE correlated well with EM for LV stroke volumes in animals (r=0.68-0.95) and with MRI for absolute volumes in patients (r-values=0.93-0.98). However, agreement between MRI and apical nine-plane, six-plane, and SAX methods in patients was better than those with apical four-plane and bi-plane methods (mean difference = -15, -18, -13, vs. -31 and -48 ml for end-diastolic volume, respectively, P
- Published
- 2002
14. Doppler-derived myocardial systolic strain rate is a strong index of left ventricular contractility
- Author
-
Jeanne K. Drinko, Peter L. Castro, Michael L. Main, Jill Odabashian, Neil L. Greenberg, Mario J. Garcia, Agnese Travaglini, Michael S. Firstenberg, James D. Thomas, and L. Leonardo Rodriguez
- Subjects
medicine.medical_specialty ,Systole ,Muscle Fibers, Skeletal ,Hemodynamics ,Doppler echocardiography ,Ventricular Function, Left ,Contractility ,Dogs ,Tissue Doppler echocardiography ,Heart Rate ,Physiology (medical) ,Internal medicine ,medicine ,Animals ,Interventricular septum ,medicine.diagnostic_test ,business.industry ,Myocardium ,Myocardial Contraction ,Echocardiography, Doppler ,medicine.anatomical_structure ,Strain rate imaging ,Cardiology ,Dobutamine ,Cardiology and Cardiovascular Medicine ,business ,medicine.drug - Abstract
Background — Myocardial fiber strain is directly related to left ventricular (LV) contractility. Strain rate can be estimated as the spatial derivative of velocities (dV/ds) obtained by tissue Doppler echocardiography (TDE). The purposes of the study were (1) to determine whether TDE-derived strain rate may be used as a noninvasive, quantitative index of contractility and (2) to compare the relative accuracy of systolic strain rate against TDE velocities alone. Methods and Results — TDE color M-mode images of the interventricular septum were recorded from the apical 4-chamber view in 7 closed-chest anesthetized mongrel dogs during 5 different inotropic stages. Simultaneous LV volume and pressure were obtained with a combined conductance–high-fidelity pressure catheter. Peak elastance (E max ) was determined as the slope of end-systolic pressure-volume relationships during caval occlusion and was used as the gold standard of LV contractility. Peak systolic TDE myocardial velocities (S m ) and peak (ε′ p ) and mean (ε′ m ) strain rates obtained at the basal septum were compared against E max by linear regression. E max as well as TDE systolic indices increased during inotropic stimulation with dobutamine and decreased with the infusion of esmolol. A stronger association was found between E max and ε′ p ( r =0.94, P y =0.29 x +0.46) and ε′ m ( r =0.88, P m ( r =0.75, P Conclusions — TDE-derived ε′ p and ε′ m are strong noninvasive indices of LV contractility. These indices appear to be more reliable than S m , perhaps by eliminating translational artifact.
- Published
- 2002
15. Determinants of diastolic myocardial tissue Doppler velocities: influences of relaxation and preload
- Author
-
Jill Odabashian, Mario J. Garcia, Jeanne K. Drinko, Michael L. Main, Neil L. Greenberg, Michael S. Firstenberg, and James D. Thomas
- Subjects
medicine.medical_specialty ,Physiology ,Diastole ,Hemodynamics ,Constriction, Pathologic ,Doppler echocardiography ,Ventricular Function, Left ,Coronary circulation ,Dogs ,Tissue Doppler echocardiography ,Physiology (medical) ,Internal medicine ,Coronary Circulation ,medicine ,Pressure ,Animals ,Ventricular Function ,medicine.diagnostic_test ,business.industry ,Esmolol ,Myocardial Contraction ,Preload ,medicine.anatomical_structure ,Echocardiography ,Cardiology ,Mitral Valve ,Dobutamine ,Venae Cavae ,business ,Blood Flow Velocity ,medicine.drug - Abstract
Myocardial tissue Doppler echocardiography (TDE) has been proposed as a tool for the assessment of diastolic function. Controversy exists regarding whether TDE measurements are influenced by preload. In this study, left ventricular volume and high-fidelity pressures were obtained in eight closed-chest dogs during intermittent caval occlusion. The time constant of isovolumic ventricular relaxation (τ) was altered with varying doses of dobutamine and esmolol. Peak early diastolic myocardial ( E m) and transmitral ( E) velocities were measured before and after preload reduction. The relative effects of changes in preload and relaxation were determined for E m and compared with their effects on E. The following results were observed: caval occlusion significantly decreased E (Δ E = 16.4 ± 3.3 cm/s, 36.6 ± 13.7%, P < 0.01) and E m (Δ E m = 1.3 ± 0.4 cm/s, 32.5 ± 26.1%, P < 0.01) under baseline conditions. However, preload reduction was similar for E under all lusitropic conditions ( P = not significant), but these effects on E m decreased with worsening relaxation. At τ < 50 ms, changes in E m with preload reduction were significantly greater (Δ E m = 2.8 ± 0.6 cm/s) than at τ = 50–65 ms (Δ E m = 1.2 ± 0.2 cm/s) and at τ >65 ms (Δ E m = 0.5 ± 0.1 cm/s, P < 0.05). We concluded that TDE E m is preload dependent. However, this effect decreases with worsening relaxation.
- Published
- 2001
16. Ultrasound contrast physics: A series on contrast echocardiography, article 3
- Author
-
Marti McCulloch, Sally Moos, Jill Odabashian, Alan D. Waggoner, Susan Jasper, Sandy Witt, David H. Adams, Pam Burgess, Vickie Moore, Eric Sisk, Jim Bednarz, Dennis Carney, and Cris Gresser
- Subjects
medicine.medical_specialty ,Series (mathematics) ,business.industry ,Ultrasound ,Contrast Media ,Contrast (music) ,Acoustics ,Microspheres ,Echocardiography ,Contrast echocardiography ,Medicine ,Humans ,Radiology, Nuclear Medicine and imaging ,Radiology ,Cardiology and Cardiovascular Medicine ,business ,Artifacts - Published
- 2000
17. 1003-2 Left and Right Atrial Systolic Function After the Maze Procedure: A Long-term Echo-Doppler Follow-up Study
- Author
-
Abdulhay Albirini, Mina K. Chung, Patrick M. McCarthy, Brian L. Luvisi, R. Daniel Murray, Annitta Morehead, Allan L. Klein, Mario J. Garcia, and Jill Odabashian
- Subjects
medicine.medical_specialty ,business.industry ,Left atrium ,Follow up studies ,Atrial fibrillation ,Atrial arrhythmias ,Systolic function ,medicine.disease ,Surgery ,medicine.anatomical_structure ,Fractional area change ,Left atrial ,Internal medicine ,cardiovascular system ,medicine ,Cardiology ,cardiovascular diseases ,business ,Cardiology and Cardiovascular Medicine ,Echo doppler - Abstract
The Maze procedure for atrial arrhythmias is designed to eliminate atrial fibrillation, and preserve atrial function. Initial data after short-term follow-up indicates that 60% patients show restoration of atrial systolic function. The long-term evaluation by echo-Doppler of left and right atrial function has not been well studied. We performed pulsed Doppler and two dimensional echocardiographyon 19 patients (16 males, mean age 54 years) who underwent the Maze procedure for atrial fibrillation and who had a follow-up study greater than 3 months (mean duration = 17 months) after the procedure. Measurements included the peak left ventricular (LV) inflow and right ventricular (RV) inflow A-wave velocity, maximum (Max) and minimum (Min) off-line digitized left atrial (LA) and right atrial (RA) areas and fractional area change (FAC). Left Atrium Right Atrium Pre Post Pre Post Max (cm 2 ) 26.1 23.1 20.8 21.7 Min (cm 2 ) 19.6 18.1 16.0 17.6 FAC (%) 27.0 22.0 23. 20.0 Twelve patients (63%) had evidence of LA function, while 16 patients (84%) had evidence of RA function. The LV inflow A-wave velocity (33 ± 9 cm/s) and the RV inflow A-wave velocity (35 ± 12 cm/s) did not differ significantly; however, the LA inflow A-wave was significantly lower than agematched controls (59 ± 14, p l 0.001). Both the mean LA FAC and the RA FAC tended to decrease at follow-up (p = 0.13). Conclusions 1) In long-term follow-up of 17 months after the Maze procedure, left atrial systolic function is preserved in 63% of patients, while the right atrial systolic function is preserved in 86% of patients. 21 LA peak A-wave velocity post Maze is considerably less than that shown in agematched controls. These findings suggest that the Maze procedure is only partially successful in achieving its goals of preserving atrial function.
- Published
- 1995
- Full Text
- View/download PDF
18. Reproducibility of new tissue doppler parameters, tissue tracking and strain, in normals and in patients with acute coronary syndrome
- Author
-
Jing Ping Sun, Marcelo Cameiro, Allan L. Klein, Zoran B. Popović, James D. Thomas, Neil Greenberg, Xiao-Fang Xu, Jill Odabashian, and Lucia Coleman
- Subjects
Reproducibility ,Acute coronary syndrome ,medicine.medical_specialty ,Tissue tracking ,business.industry ,Strain (injury) ,medicine.disease ,symbols.namesake ,Internal medicine ,medicine ,Cardiology ,symbols ,In patient ,Cardiology and Cardiovascular Medicine ,business ,Doppler effect - Published
- 2002
19. Regional variation in myocardial intensity of the normal heart following intravenous contrast may affect assessment of myocardial perfusion
- Author
-
Allan L. Klein, W.A. Jaber, James D. Thomas, Jill Odabashian, David L. Prior, and Lisa A. Cardon
- Subjects
Pulmonary and Respiratory Medicine ,Intravenous contrast ,medicine.medical_specialty ,business.industry ,Internal medicine ,medicine ,Cardiology ,Cardiology and Cardiovascular Medicine ,business ,Affect (psychology) ,Perfusion ,Normal heart ,Intensity (physics) - Published
- 2000
20. Prevalence of Atrial Thrombi in Patients Undergoing Electrical Cardioversion - Results From the ACUTE Registry
- Author
-
S.C. Enar, Maran Thamilarasan, Lisa A. Cardon, Susan E. Vaughn, Deborah A. Agler, Allan L. Klein, Richard A. Grimm, Annitta Morehead, Mario J. Garcia, and Jill Odabashian
- Subjects
Electrical cardioversion ,medicine.medical_specialty ,business.industry ,Internal medicine ,medicine ,Cardiology ,In patient ,Cardiology and Cardiovascular Medicine ,business - Published
- 1998
21. Harmonic versus fundamental echocardiographic imaging for endocardial definition
- Author
-
William J. Stewart, James D. Thomas, David N. Rubin, Brian L. Luvisi, David A. Homa, Lisa A. Cardon, N. Yazbek, Jill Odabashian, and Mario J. Garcia
- Subjects
business.industry ,Acoustics ,Harmonic ,Medicine ,Cardiology and Cardiovascular Medicine ,business - Published
- 1998
22. A comparison of frequency conversion technology, power motion imaging, and intravenous albunex for improved endocardial border resolution in patients with technically difficult echocardiograms
- Author
-
Lisa A. Cardon, Michael L. Main, Craig R. Asher, Allan L. Klein, and Jill Odabashian
- Subjects
Frequency conversion ,business.industry ,Resolution (electron density) ,Medicine ,In patient ,Cardiology and Cardiovascular Medicine ,Endocardial border ,business ,Biomedical engineering ,Power (physics) - Published
- 1998
23. Recurrent cardiac events correlate with ischemia or viability at dobutamine echo in patients with left ventricular dysfunction
- Author
-
James D. Thomas, William J. Stewart, M.J. Williams, Thomas H. Marwick, Michael S. Lauer, and Jill Odabashian
- Subjects
medicine.medical_specialty ,business.industry ,Echo (computing) ,Ischemia ,medicine.disease ,Internal medicine ,Cardiology ,Medicine ,Radiology, Nuclear Medicine and imaging ,Dobutamine ,In patient ,Cardiology and Cardiovascular Medicine ,business ,medicine.drug - Published
- 1995
24. Prognostic value of dobutamine echocardiography in patients with left ventricular dysfunction
- Author
-
Thomas H. Marwick, James D. Thomas, M. John Williams, Michael S. Lauer, and Jill Odabashian
- Subjects
Male ,medicine.medical_specialty ,Cardiotonic Agents ,Heart Diseases ,Ischemia ,Cardiomyopathy ,Myocardial Ischemia ,Coronary Angiography ,Coronary artery disease ,Electrocardiography ,Ventricular Dysfunction, Left ,Risk Factors ,Internal medicine ,Dobutamine ,Stress Echocardiography ,Medicine ,Humans ,Myocardial infarction ,cardiovascular diseases ,Aged ,Aged, 80 and over ,Ejection fraction ,business.industry ,Hemodynamics ,Middle Aged ,medicine.disease ,Prognosis ,Survival Analysis ,Echocardiography ,Heart failure ,Anesthesia ,Cardiology ,Exercise Test ,cardiovascular system ,Regression Analysis ,Female ,Cardiology and Cardiovascular Medicine ,business ,medicine.drug ,Follow-Up Studies - Abstract
Objectives.This study sought to establish the prognostic implications of ischemic and viable myocardium identified by dobutamine echocardiography in patients with left ventricular dysfunction.Background.Recent studies have suggested that in patients with viable myocardium identified by positron emission tomography, medical treatment is associated with recurrent cardiac events. Dobutamine echocardiography has been used to identify viable myocardium in patients with left ventricular dysfunction, but the prognostic significance of this test is undefined.Methods.One hundred thirty-six consecutive patients (mean [±SD] age 67 ± 7.9 years; 104 men) with moderate or severe left ventricular dysfunction (left ventricular ejection fraction 30 ± 5%) undergoing dobutamine echocardiography were included in the study. Dobutamine was administered using a standard incremental protocol (5 to 40 μg/kg body weight per min intravenously in 3-min stages) with additional atropine (1 mg intravenously) as required. Standard body weight echocardiographic views were digitized on-line and compared using a side-by-side display. Viable myocardium was identified by enhancement of regional function at low dose (
- Full Text
- View/download PDF
25. Why does tissue harmonic imaging improve image quality: a quantitative examination demonstrating side-lobe suppression
- Author
-
William J. Stewart, James D. Thomas, N. Yazbek, B. Livisi, Jill Odabashian, David N. Rubin, and David A. Homa
- Subjects
medicine.medical_specialty ,Side lobe ,business.industry ,Image quality ,medicine ,Second-harmonic imaging microscopy ,Radiology ,Cardiology and Cardiovascular Medicine ,business - Full Text
- View/download PDF
Catalog
Discovery Service for Jio Institute Digital Library
For full access to our library's resources, please sign in.