13 results on '"Loutfi-Krauss, Britta"'
Search Results
2. Treatment planning for spinal radiosurgery: A competitive multiplatform benchmark challenge
- Author
-
Moustakis, Christos, Chan, Mark K. H., Kim, Jinkoo, Nilsson, Joakim, Bergman, Alanah, Bichay, Tewfik J., Palazon Cano, Isabel, Cilla, Savino, Deodato, Francesco, Doro, Raffaela, Dunst, Jürgen, Eich, Hans Theodor, Fau, Pierre, Fong, Ming, Haverkamp, Uwe, Heinze, Simon, Hildebrandt, Guido, Imhoff, Detlef, de Klerck, Erik, Köhn, Janett, Lambrecht, Ulrike, Loutfi-Krauss, Britta, Ebrahimi, Fatemeh, Masi, Laura, Mayville, Alan H., Mestrovic, Ante, Milder, Maaike, Morganti, Alessio G., Rades, Dirk, Ramm, Ulla, Rödel, Claus, Siebert, Frank-Andre, den Toom, Wilhelm, Wang, Lei, Wurster, Stefan, Schweikard, Achim, Soltys, Scott G., Ryu, Samuel, and Blanck, Oliver
- Published
- 2018
- Full Text
- View/download PDF
3. Usability and accuracy of high-resolution detectors for daily quality assurance for robotic radiosurgery
- Author
-
Loutfi-Krauss Britta, Damme Marie-Christin, Stelljes Tenzin Sonam, Chan Mark KH, Siebert Frank-Andre, Poppe Björn, Ramm Ulla, and Blanck Oliver
- Subjects
cyberknife ,robotic radiosurgery ,automatic quality assurance ,high-resolution arrays ,gafchromic film ,Medicine - Abstract
For daily CyberKnife QA a Winston-Lutz-Test (Automated-Quality-Assurance, AQA) is used to determine sub-millimeter deviations in beam delivery accuracy. This test is performed using gafchromic film, an extensive and user-dependent method requiring the use of disposables. We therefore analyzed the usability and accuracy of high-resolution detector arrays. We analyzed a liquid-filled ionization-chamber array (Octavius 1000SRS, PTW, Germany), which has a central resolution of 2.5mm. To test sufficient sensitivity, beam profiles with robot shifts of 0.1mm along the arrays' axes were measured. The detected deviation between the shifted and central profile were compared to the real robot's position. We then compared the results to the SRS-Profiler (SunNuclear, USA) with 4.0mm resolution and to the Nonius (QUART, Germany), a single-line diode detector with 2.8mm resolution. Finally, AQA variance and usability were analyzed performing a number of AQA tests over time, which required the use of specially designed fixtures for each array, and the results were compared to film. Concerning sensitivity, the 1000SRS detected the beam profile shifts with a maximum difference of 0.11mm (mean deviation = 0.03mm) compared to the actual robot shift. The Nonius and SRS-Profiler showed differences of up to 0.15mm and 0.69mm with mean deviation of 0.05mm and 0.18mm, respectively. Analyzing the variation of AQA results over time, the 1000SRS showed a comparable standard deviation to film (0.26mm vs. 0.18mm). The SRS-Profiler and the Nonius showed a standard deviation of 0.16mm and 0.24mm, respectively. The 1000SRS seems to provide equivalent accuracy and sensitivity to the gold standard film when performing daily AQA tests. Compared to other detectors in our study the sensitivity as well as the accuracy of the 1000SRS appears to be superior and more user-friendly. Furthermore, no significant modification of the standard AQA procedure is required when introducing 1000SRS for CyberKnife AQA.
- Published
- 2017
- Full Text
- View/download PDF
4. Stereotactic radiosurgery combined with immune checkpoint inhibitors or kinase inhibitors for patients with multiple brain metastases of malignant melanoma
- Author
-
Stera, Susanne, Balermpas, Panagiotis, Blanck, Oliver, Wolff, Robert, Wurster, Stefan, Baumann, Rene, Szücs, Marcella, Loutfi-Krauss, Britta, Wilhelm, Maria-Lisa, Seifert, Volker, Rades, Dirk, Rödel, Claus, Dunst, Jürgen, Hildebrandt, Guido, Arnold, Andreas, Meissner, Markus, and Kähler, Katharina C.
- Published
- 2019
- Full Text
- View/download PDF
5. Technological quality requirements for stereotactic radiotherapy
- Author
-
Schmitt, Daniela, Blanck, Oliver, Gauer, Tobias, Fix, Michael K., Brunner, Thomas B., Fleckenstein, Jens, Loutfi-Krauss, Britta, Manser, Peter, Werner, Rene, Wilhelm, Maria-Lisa, Baus, Wolfgang W., and Moustakis, Christos
- Subjects
SBRT ,Consensus ,Quality Assurance, Health Care ,Germany ,Technique ,Review Article ,Recommendations ,FSRT ,Radiosurgery ,Radiation Dosage ,Societies, Medical ,SRS - Abstract
This review details and discusses the technological quality requirements to ensure the desired quality for stereotactic radiotherapy using photon external beam radiotherapy as defined by the DEGRO Working Group Radiosurgery and Stereotactic Radiotherapy and the DGMP Working Group for Physics and Technology in Stereotactic Radiotherapy. The covered aspects of this review are 1) imaging for target volume definition, 2) patient positioning and target volume localization, 3) motion management, 4) collimation of the irradiation and beam directions, 5) dose calculation, 6) treatment unit accuracy, and 7) dedicated quality assurance measures. For each part, an expert review for current state-of-the-art techniques and their particular technological quality requirement to reach the necessary accuracy for stereotactic radiotherapy divided into intracranial stereotactic radiosurgery in one single fraction (SRS), intracranial fractionated stereotactic radiotherapy (FSRT), and extracranial stereotactic body radiotherapy (SBRT) is presented. All recommendations and suggestions for all mentioned aspects of stereotactic radiotherapy are formulated and related uncertainties and potential sources of error discussed. Additionally, further research and development needs in terms of insufficient data and unsolved problems for stereotactic radiotherapy are identified, which will serve as a basis for the future assignments of the DGMP Working Group for Physics and Technology in Stereotactic Radiotherapy. The review was group peer-reviewed, and consensus was obtained through multiple working group meetings. Electronic supplementary material The online version of this article (10.1007/s00066-020-01583-2) contains supplementary material, which is available to authorized users.
- Published
- 2020
6. New possibilities for volumetric-modulated arc therapy using the AgilityTM 160-leaf multileaf collimator
- Author
-
Blümer, Nadine, Scherf, Christian, Köhn, Janett, Kara, Eugen, Loutfi-Krauß, Britta, Imhoff, Detlef, Rödel, Claus, Ramm, Ulla, and Licher, Jörg
- Published
- 2014
- Full Text
- View/download PDF
7. Technological quality requirements for stereotactic radiotherapy Expert review group consensus from the DGMP Working Group for Physics and Technology in Stereotactic Radiotherapy
- Author
-
Schmitt, Daniela, Blanck, Oliver, Gauer, Tobias, Fix, Michael K., Brunner, Thomas B., Fleckenstein, Jens, Loutfi-Krauss, Britta, Manser, Peter, Werner, Rene, Wilhelm, Maria-Lisa, Baus, Wolfgang W., Moustakis, Christos, Schmitt, Daniela, Blanck, Oliver, Gauer, Tobias, Fix, Michael K., Brunner, Thomas B., Fleckenstein, Jens, Loutfi-Krauss, Britta, Manser, Peter, Werner, Rene, Wilhelm, Maria-Lisa, Baus, Wolfgang W., and Moustakis, Christos
- Abstract
This review details and discusses the technological quality requirements to ensure the desired quality for stereotactic radiotherapy using photon external beam radiotherapy as defined by the DEGRO Working Group Radiosurgery and Stereotactic Radiotherapy and the DGMP Working Group for Physics and Technology in Stereotactic Radiotherapy. The covered aspects of this review are 1) imaging for target volume definition, 2) patient positioning and target volume localization, 3) motion management, 4) collimation of the irradiation and beam directions, 5) dose calculation, 6) treatment unit accuracy, and 7) dedicated quality assurance measures. For each part, an expert review for current state-of-the-art techniques and their particular technological quality requirement to reach the necessary accuracy for stereotactic radiotherapy divided into intracranial stereotactic radiosurgery in one single fraction (SRS), intracranial fractionated stereotactic radiotherapy (FSRT), and extracranial stereotactic body radiotherapy (SBRT) is presented. All recommendations and suggestions for all mentioned aspects of stereotactic radiotherapy are formulated and related uncertainties and potential sources of error discussed. Additionally, further research and development needs in terms of insufficient data and unsolved problems for stereotactic radiotherapy are identified, which will serve as a basis for the future assignments of the DGMP Working Group for Physics and Technology in Stereotactic Radiotherapy. The review was group peer-reviewed, and consensus was obtained through multiple working group meetings.
- Published
- 2020
8. Repeated in-field radiosurgery for locally recurrent brain metastases: Feasibility, results and survival in a heavily treated patient cohort
- Author
-
Balermpas, Panagiotis, Stera, Susanne, Müller-von der Grün, Jens, Loutfi-Krauss, Britta, Forster, Marie-Thérèse, Wagner, Marlies, Keller, Christian, Rödel, Claus, Seifert, Volker, Blanck, Oliver, Wolff, Robert, and Sherman, Jonathan H.
- Subjects
Male ,Lung Neoplasms ,Cancer Treatment ,lcsh:Medicine ,Stereotactic Radiosurgery ,Toxicology ,Pathology and Laboratory Medicine ,Lung and Intrathoracic Tumors ,Nervous System Procedures ,Robotic Surgical Procedures ,Carcinoma, Non-Small-Cell Lung ,Breast Tumors ,Medicine and Health Sciences ,lcsh:Science ,Melanoma ,Neurological Tumors ,Aged, 80 and over ,Brain Neoplasms ,Brain ,Middle Aged ,Magnetic Resonance Imaging ,Treatment Outcome ,Oncology ,Neurology ,Retreatment ,Female ,Research Article ,Adult ,Breast Neoplasms ,Surgical and Invasive Medical Procedures ,Radiosurgery ,Necrosis ,Signs and Symptoms ,Diagnostic Medicine ,parasitic diseases ,Breast Cancer ,Humans ,ddc:610 ,Radiation Injuries ,Aged ,Retrospective Studies ,Toxicity ,Patient Selection ,lcsh:R ,Cancers and Neoplasms ,Biology and Life Sciences ,Survival Analysis ,Non-Small Cell Lung Cancer ,Brain Metastasis ,Lesions ,Feasibility Studies ,lcsh:Q ,Neoplasm Recurrence, Local ,Follow-Up Studies - Abstract
Purpose: Stereotactic radiosurgery (SRS) is an established primary treatment for newly diagnosed brain metastases with high local control rates. However, data about local re-irradiation in case of local failure after SRS (re-SRS) are rare. We evaluated the feasibility, efficacy and patient selection characteristics in treating locally recurrent metastases with a second course of SRS. Methods: We retrospectively evaluated patients with brain metastases treated with re-SRS for local tumor progression between 2011 and 2017. Patient and treatment characteristics as well as rates of tumor control, survival and toxicity were analyzed. Results: Overall, 32 locally recurrent brain metastases in 31 patients were irradiated with re-SRS. Median age at re-SRS was 64.9 years. The primary histology was breast cancer and non-small-cellular lung cancer (NSCLC) in respectively 10 cases (31.3%), in 5 cases malignant melanoma (15.6%). In the first SRS-course 19 metastases (59.4%) and in the re-SRS-course 29 metastases (90.6%) were treated with CyberKnife® and the others with Gamma Knife. Median planning target volume (PTV) for re-SRS was 2.5 cm3 (range, 0.1–37.5 cm3) and median dose prescribed to the PTV was 19 Gy (range, 12–28 Gy) in 1–5 fractions to the median 69% isodose (range, 53–80%). The 1-year overall survival rate was 61.7% and the 1-year local control rate was 79.5%. The overall rate of radiological radio-necrosis was 16.1% and four patients (12.9%) experienced grade ≥ 3 toxicities. Conclusions: A second course of SRS for locally recurrent brain metastases after prior local SRS appears to be feasible with acceptable toxicity and can be considered as salvage treatment option for selected patients with high performance status. Furthermore, this is the first study utilizing robotic radiosurgery for this indication, as an additional option for frameless fractionated treatment.
- Published
- 2018
9. Second infield re‐irradiation with a resulting cumulative equivalent dose (EQD2max) of >180 Gy for patients with recurrent head and neck cancer
- Author
-
Grün, Jens, primary, Köhn, Janett, additional, Loutfi‐Krauss, Britta, additional, Blanck, Oliver, additional, Rödel, Claus, additional, and Balermpas, Panagiotis, additional
- Published
- 2018
- Full Text
- View/download PDF
10. Repeated in-field radiosurgery for locally recurrent brain metastases : feasibility, results and survival in a heavily treated patient cohort
- Author
-
Sherman, Jonathan H., Balermpas, Panagiotis, Stera, Susanne, Müller-von der Grün, Jens, Loutfi-Krauss, Britta, Forster, Marie-Thérèse, Wagner, Marlies, Keller, Christian, Rödel, Claus, Seifert, Volker, Blanck, Oliver, Wolff, Robert Jürgen, Sherman, Jonathan H., Balermpas, Panagiotis, Stera, Susanne, Müller-von der Grün, Jens, Loutfi-Krauss, Britta, Forster, Marie-Thérèse, Wagner, Marlies, Keller, Christian, Rödel, Claus, Seifert, Volker, Blanck, Oliver, and Wolff, Robert Jürgen
- Abstract
Purpose: Stereotactic radiosurgery (SRS) is an established primary treatment for newly diagnosed brain metastases with high local control rates. However, data about local re-irradiation in case of local failure after SRS (re-SRS) are rare. We evaluated the feasibility, efficacy and patient selection characteristics in treating locally recurrent metastases with a second course of SRS. Methods: We retrospectively evaluated patients with brain metastases treated with re-SRS for local tumor progression between 2011 and 2017. Patient and treatment characteristics as well as rates of tumor control, survival and toxicity were analyzed. Results: Overall, 32 locally recurrent brain metastases in 31 patients were irradiated with re-SRS. Median age at re-SRS was 64.9 years. The primary histology was breast cancer and non-small-cellular lung cancer (NSCLC) in respectively 10 cases (31.3%), in 5 cases malignant melanoma (15.6%). In the first SRS-course 19 metastases (59.4%) and in the re-SRS-course 29 metastases (90.6%) were treated with CyberKnife® and the others with Gamma Knife. Median planning target volume (PTV) for re-SRS was 2.5 cm3 (range, 0.1–37.5 cm3) and median dose prescribed to the PTV was 19 Gy (range, 12–28 Gy) in 1–5 fractions to the median 69% isodose (range, 53–80%). The 1-year overall survival rate was 61.7% and the 1-year local control rate was 79.5%. The overall rate of radiological radio-necrosis was 16.1% and four patients (12.9%) experienced grade ≥ 3 toxicities. Conclusions: A second course of SRS for locally recurrent brain metastases after prior local SRS appears to be feasible with acceptable toxicity and can be considered as salvage treatment option for selected patients with high performance status. Furthermore, this is the first study utilizing robotic radiosurgery for this indication, as an additional option for frameless fractionated treatment.
- Published
- 2018
11. Second infield re‐irradiation with a resulting cumulative equivalent dose (EQD2max) of >180 Gy for patients with recurrent head and neck cancer.
- Author
-
Grün, Jens, Köhn, Janett, Loutfi‐Krauss, Britta, Blanck, Oliver, Rödel, Claus, and Balermpas, Panagiotis
- Subjects
HEAD & neck cancer ,HEAD & neck cancer patients - Abstract
Background: For locally recurrent head and neck cancer, re‐irradiation with modern techniques like stereotactic body radiotherapy is a promising, possibly curative alternative to palliative systemic therapy. Methods: We report on 1 patient with nasopharyngeal carcinoma (NPC) and 1 patient with cutaneous squamous cell carcinoma (SCC). Both patients received full dose primary treatment (>66 Gy, EQD2), full dose re‐irradiation (>50 Gy, EQD2), and a second course of re‐irradiation via robotic radiosurgery (CyberKnife) for a second local recurrence. Results: Both treatments resulted in adequate tumor response. No grade III‐IV acute or late toxicities occurred. Follow‐up at 6 months after third irradiation showed partial remission for the patient with NPC. In the second case (SCC), no toxicities occurred and the tumor was in remission 18 months after last treatment. Conclusion: These cases show that a second course of re‐irradiation utilizing modern techniques like robotic radiosurgery might be feasible for carefully selected patients with head and neck cancer. [ABSTRACT FROM AUTHOR]
- Published
- 2019
- Full Text
- View/download PDF
12. High resolution ion chamber array delivery quality assurance for robotic radiosurgery: Commissioning and validation
- Author
-
Blanck, Oliver, primary, Masi, Laura, additional, Chan, Mark K.H., additional, Adamczyk, Sebastian, additional, Albrecht, Christian, additional, Damme, Marie-Christin, additional, Loutfi-Krauss, Britta, additional, Alraun, Manfred, additional, Fehr, Roman, additional, Ramm, Ulla, additional, Siebert, Frank-Andre, additional, Stelljes, Tenzin Sonam, additional, Poppinga, Daniela, additional, and Poppe, Björn, additional
- Published
- 2016
- Full Text
- View/download PDF
13. Second infield re-irradiation with a resulting cumulative equivalent dose (EQD2 max ) of >180 Gy for patients with recurrent head and neck cancer.
- Author
-
von der Grün J, Köhn J, Loutfi-Krauss B, Blanck O, Rödel C, and Balermpas P
- Subjects
- Aged, 80 and over, Carcinoma, Squamous Cell diagnostic imaging, Carcinoma, Squamous Cell pathology, Dose-Response Relationship, Radiation, Epistaxis diagnosis, Epistaxis etiology, Follow-Up Studies, Head and Neck Neoplasms diagnostic imaging, Humans, Magnetic Resonance Imaging methods, Male, Neoplasm Invasiveness pathology, Neoplasm Recurrence, Local diagnostic imaging, Neoplasm Staging, Radiotherapy Dosage, Risk Assessment, Salvage Therapy methods, Treatment Outcome, Carcinoma, Squamous Cell radiotherapy, Head and Neck Neoplasms radiotherapy, Neoplasm Recurrence, Local radiotherapy, Radiotherapy, Conformal methods, Re-Irradiation methods
- Abstract
Background: For locally recurrent head and neck cancer, re-irradiation with modern techniques like stereotactic body radiotherapy is a promising, possibly curative alternative to palliative systemic therapy., Methods: We report on 1 patient with nasopharyngeal carcinoma (NPC) and 1 patient with cutaneous squamous cell carcinoma (SCC). Both patients received full dose primary treatment (>66 Gy, EQD2), full dose re-irradiation (>50 Gy, EQD2), and a second course of re-irradiation via robotic radiosurgery (CyberKnife) for a second local recurrence., Results: Both treatments resulted in adequate tumor response. No grade III-IV acute or late toxicities occurred. Follow-up at 6 months after third irradiation showed partial remission for the patient with NPC. In the second case (SCC), no toxicities occurred and the tumor was in remission 18 months after last treatment., Conclusion: These cases show that a second course of re-irradiation utilizing modern techniques like robotic radiosurgery might be feasible for carefully selected patients with head and neck cancer., (© 2018 Wiley Periodicals, Inc.)
- Published
- 2019
- Full Text
- View/download PDF