15 results on '"Morgan HT"'
Search Results
2. An improved method for estimating the entrance exposure in diagnostic radiographic examinations
- Author
-
Zamenhof, RG, primary, Shahabi, S, additional, and Morgan, HT, additional
- Published
- 1987
- Full Text
- View/download PDF
3. Synthesis and characterisation of second-generation metallodithiolene complexes of the type [Tp*ME(dithiolene)](M=Mo, W; E=O, S) and a novel 'organoscorpionate' complex of tungsten.
- Author
-
Sproules SA, Morgan HT, Doonan CJ, White JM, and Young CG
- Abstract
Paramagnetic, chalcogenido-M(v) dithiolene complexes, [Tp*ME{S2C2(CO2Me)2}][M=Mo, E=O, S; M=W, E=O, S; Tp*=hydrotris(3,5-dimethylpyrazol-1-yl)borate] are generated in the reactions of dimethyl acetylenedicarboxylate (DMAC) and the sulfur-rich complexes NEt4[Tp*MoS(S4)] and NEt4[Tp*WS3]; the oxo complexes result from hydrolysis of the initial sulfido products. As well, a novel 'organoscorpionate' complex, [W{S2C2(CO2Me)2}{SC2(CO2Me)2-Tp*}], has been isolated from the reactions of NEt4[Tp*WS3] with excess DMAC. Complexes , and have been isolated and characterised by microanalytical, mass spectrometric, spectroscopic and (for and) X-ray crystallographic techniques. Complexes and have been partially characterised by mass spectrometry and IR and EPR spectroscopy. Six-coordinate, distorted-octahedral contains a terminal sulfido ligand (W=S=2.108(3)A), a bidentate dithiolene ligand (S-Cav=1.758 A, C=C=1.332(10)A) and a fac-tridentate Tp* ligand. Seven-coordinate contains a planar, bidentate dithiolene ligand (S-Cav=1.746 A, C=C=1.359(5)A) and a novel pentadentate 'organoscorpionate' ligand formed by the melding of DMAC, sulfido and trispyrazolylborate units. The latter is coordinated through two pyrazolyl N atoms (kappa2-N,N') and a tridentate kappa3-S,C,C' unit appended to N-beta of the third (uncoordinated) pyrazolyl group. The second-generation [Tp*ME(dithiolene)] complexes represent a refinement on first-generation [Tp*ME(arene-1,2-dithiolate)] complexes and their synthesis affords an opportunity to compare and contrast the electronic structures of true vs. pseudo-dithiolene ligands in otherwise analogous complexes.
- Published
- 2005
- Full Text
- View/download PDF
4. Techniques and applications of automatic tube current modulation for CT.
- Author
-
Kalra MK, Maher MM, Toth TL, Schmidt B, Westerman BL, Morgan HT, and Saini S
- Subjects
- Equipment Design, Humans, Radiation Dosage, Radiographic Image Enhancement instrumentation, Radiographic Image Enhancement methods, Technology, Radiologic instrumentation, Tomography, Spiral Computed instrumentation, Tomography, X-Ray Computed instrumentation, Technology, Radiologic methods, Tomography Scanners, X-Ray Computed, Tomography, X-Ray Computed methods
- Abstract
Introduction of slip-ring technology with subsequent development of single- and multi-detector row helical computed tomographic (CT) scanners have expanded the applications of CT, leading to a substantial increase in the number of CT examinations being performed. Owing to concerns about the resultant increase in associated radiation dose, many technical innovations have been introduced. One such innovation is automatic tube current modulation. The purpose of automatic tube current modulation is to maintain constant image quality regardless of patient attenuation characteristics, thus allowing radiation dose to patients to be reduced. This review discusses the principles, clinical use, and limitations of different automatic tube current modulation techniques., ((c) RSNA, 2004.)
- Published
- 2004
- Full Text
- View/download PDF
5. Dose reduction for CT pediatric imaging.
- Author
-
Morgan HT
- Subjects
- Child, Clinical Protocols standards, Humans, Phantoms, Imaging, Radiation Dosage, Radiometry methods, Tomography, X-Ray Computed instrumentation, Tomography, X-Ray Computed standards
- Published
- 2002
- Full Text
- View/download PDF
6. Iterative reconstruction of fluorine-18 SPECT using geometric point response correction.
- Author
-
Zeng GL, Gullberg GT, Bai C, Christian PE, Trisjono F, Di Bella EV, Tanner JW, and Morgan HT
- Subjects
- Aged, Brain diagnostic imaging, Female, Fluorodeoxyglucose F18, Heart diagnostic imaging, Humans, Male, Middle Aged, Phantoms, Imaging, Radiopharmaceuticals, Tomography, Emission-Computed, Single-Photon instrumentation, Algorithms, Fluorine Radioisotopes, Image Processing, Computer-Assisted methods, Tomography, Emission-Computed, Single-Photon methods
- Abstract
Unlabelled: This article demonstrates resolution recovery in 18F SPECT image reconstruction by using an iterative algorithm that corrects for the system geometric response., Methods: Patient and phantom studies were performed using a Picker PRISM 3000 three-detector SPECT system (Picker International, Inc., Cleveland, OH) to image 18F with 511 keV collimators. A measured point response function of the imaging system was used in an iterative reconstruction algorithm in which the projector and backprojector modeled the system point response function by using an efficient layer-by-layer blurring technique. The blurring function was a five-element kernel in the shape of a cross. The iterative reconstruction algorithm was an ordered-subset maximum-likelihood expectation maximization algorithm., Results: The iterative reconstruction algorithm with geometric response correction showed an improvement in resolution over the filtered backprojection reconstruction and the iterative reconstruction without correction., Conclusion: The proposed iterative reconstruction algorithm with geometric response correction is efficient and effective with significant resolution recovery.
- Published
- 1998
7. Transmission imaging of large attenuators using a slant hole collimator on a three-headed SPECT system.
- Author
-
King MA, Luo D, Dahlberg ST, Villegas BJ, Penney BC, and Morgan HT
- Subjects
- Equipment Design, Humans, Male, Mathematics, Probability, Technetium Tc 99m Sestamibi, Heart diagnostic imaging, Phantoms, Imaging, Tomography, Emission-Computed, Single-Photon instrumentation, Tomography, Emission-Computed, Single-Photon methods
- Abstract
By combining conjugate views, truncation-free attenuation profiles of patients can be obtained by using slant hole collimators on three-headed SPECT systems. The alterations in reconstruction algorithms necessary for use with slant hole collimators and potential image artifacts are discussed. Based on an evaluation of the size of objects that can be imaged without truncation and the size of the overlap region in the conjugate views, a 15 degrees slant angle was determined to be optimal. Studies with a 30 degrees slant hole collimator verified the ability of slant hole transmission imaging to provide accurate, truncation-free attenuation maps of a 56 cm lateral width phantom. The center of rotation was determined to be dependent on the slant angle and radius of rotation of the slant collimator. These studies also demonstrated that the spatial resolution in the transaxial plane of the attenuation maps depends on radius of rotation of the slant hole collimator, but does not depend on the radius of rotation of an uncollimated transmission source. A multiline transmission source was investigated for use with estimating the attenuation map in Tc-99m labeled sestamibi perfusion imaging.
- Published
- 1996
- Full Text
- View/download PDF
8. A Monte Carlo investigation of artifacts caused by liver uptake in single-photon emission computed tomography perfusion imaging with technetium 99m-labeled agents.
- Author
-
King MA, Xia W, deVries DJ, Pan TS, Villegas BJ, Dahlberg S, Tsui BM, Ljungberg MH, and Morgan HT
- Subjects
- Computer Simulation, Humans, Male, Monte Carlo Method, Phantoms, Imaging, Artifacts, Heart diagnostic imaging, Liver diagnostic imaging, Technetium Compounds, Tomography, Emission-Computed, Single-Photon
- Abstract
Background: Significant hepatobiliary accumulation of technetium 99m-labeled cardiac perfusion agents has been shown to cause alterations in the apparent localization of the agents in the cardiac walls. A Monte Carlo study was conducted to investigate the hypothesis that the cardiac count changes are due to the inconsistencies in the projection data input to reconstruction, and that correction of the causes of these inconsistencies before reconstruction, or including knowledge of the physics underlying them in the reconstruction algorithm, would virtually eliminate these artifacts., Methods and Results: The SIMIND Monte Carlo package was used to simulate 64 x 64 pixel projection images at 128 angles of the three-dimensional mathematical cardiac-torso (MCAT) phantom. Simulations were made of (1) a point source in the liver, (2) cardiac activity only, and (3) hepatic activity only. The planar projections and reconstructed point spread functions (PSFs) of the point source in the liver were investigated to study the nature of the inconsistencies introduced into the projections by imaging, and how these affect the distribution of counts in the reconstructed slices. Bull's eye polar maps of the counts at the center of the left ventricular wall of filtered back-projection (FBP) and maximum-likelihood expectation-maximization (MLEM) reconstructions of projections with solely cardiac activity, and with cardiac activity plus hepatic activity scaled to have twice the cardiac concentration, were compared to determine the magnitude and location of apparent changes in cardiac activity when hepatic activity is present. Separate simulations were made to allow the investigation of stationary spatial resolution, distance-dependent spatial resolution, attenuation, and scatter. The point source projections showed significant inconsistencies as a function of projection angle with the largest effect being caused by attenuation. When consistent projections were simulated, no significant impact of hepatic activity on cardiac counts was noted with FBP, or 100 iterations of MLEM. With inconsistent projections, reconstruction of 180 degrees resulted in greater apparent cardiac count losses than did 360 degrees reconstruction for both FBP and MLEM. The incorporation of attenuation correction in MLEM reconstruction reduced the changes in cardiac counts to that seen in simulations in which attenuation was not included, but resulted in increased apparent localization of activity in the posterior wall of the left ventricle when scatter was present in the simulated images., Conclusions: The apparent alterations in cardiac counts when significant hepatic localization is present is due to the inconsistency of the projections inherent in imaging. Prior correction of these, or accounting for them in the reconstruction algorithm, will virtually eliminate them as causes of artifactual changes in localization. Attenuation correction and scatter correction are both required to overcome the major sources of apparent count changes in the heart associated with hepatic uptake.
- Published
- 1996
- Full Text
- View/download PDF
9. A transmission-map-based scatter correction technique for SPECT in inhomogeneous media.
- Author
-
Welch A, Gullberg GT, Christian PE, Datz FL, and Morgan HT
- Subjects
- Humans, Mathematics, Models, Theoretical, Scattering, Radiation, Technetium, Tomography, Emission-Computed, Single-Photon instrumentation, Monte Carlo Method, Phantoms, Imaging, Tomography, Emission-Computed, Single-Photon methods
- Abstract
In this paper a method of modeling the distribution of scattered events in emission projection data is developed and applied. This method is based on the use of a transmission map to define the inhomogeneous scattering object. The key point is the use of the set of line integrals calculated as part of the attenuation correction technique, as the basis of a model of the distribution of scattered events. The probability of a photon being scattered through a given angle and being detected in the emission energy window is approximated using a Gaussian function. The parameters of this Gaussian are determined using Monte Carlo generated parallel-beam scatter line spread functions from a nonuniformly attenuating phantom. The model is incorporated into a two-dimensional projector-backprojector and used with the Expectation-Maximization-Maximum-Likelihood algorithm for the reconstruction of fan-beam phantom data. The correction is shown to perform well for a phantom that varies slowly in the axial direction. For the more clinically realistic situation of a torso phantom, the method produces improvements in terms of blood pool to myocardium contrast, but does not restore the contrast to the level exhibited in a reconstruction from "scatter free" data.
- Published
- 1995
- Full Text
- View/download PDF
10. SPECT imaging of fluorine-18.
- Author
-
Leichner PK, Morgan HT, Holdeman KP, Harrison KA, Valentino F, Lexa R, Kelly RF, Hawkins WG, and Dalrymple GV
- Subjects
- Gamma Cameras, Humans, Models, Structural, Sensitivity and Specificity, Fluorine Radioisotopes, Image Processing, Computer-Assisted, Tomography, Emission-Computed, Single-Photon instrumentation, Tomography, Emission-Computed, Single-Photon methods
- Abstract
Unlabelled: The objective of this work was to determine the potential clinical usefulness of SPECT to image 511-keV annihilation photons., Methods: A triple-headed gamma camera equipped with ultra-high-energy collimators was used to image 18F. Sensitivity measurements were carried out and the FWHM and FWTM were determined in air and for a unit-density scattering medium. Additionally, tomographic phantom studies were acquired to evaluate image quality., Results: The sensitivities of the three cameras were, for all practical purposes, identical. At a source-to-collimator distance of 100 mm, the FWHM and FWTM were 13 and 29 mm, respectively. A tomographic phantom study demonstrated that spheres with a diameter of 20 mm were well resolved when filled with 18F activity and placed inside a water-filled phantom., Conclusion: The triple-headed SPECT camera in this investigation is a practical means of acquiring tomographic 18F images. The reconstructed slices were of sufficient quality to be of value in some clinical studies.
- Published
- 1995
11. Review of convergent beam tomography in single photon emission computed tomography.
- Author
-
Gullberg GT, Zeng GL, Datz FL, Christian PE, Tung CH, and Morgan HT
- Subjects
- Brain diagnostic imaging, Heart diagnostic imaging, Humans, Models, Structural, Tomography, Emission-Computed, Single-Photon instrumentation, Tomography, Emission-Computed, Single-Photon methods
- Abstract
Investigation of convergent-beam single photon emission computed tomography (SPECT) is actively being pursued to evaluate its clinical potentials. Fan-beam, cone-beam, pin-hole and astigmatic collimators are being used with rotating gamma cameras having large crystal areas, to increase the sensitivity for emission and transmission computed tomography of small organs such as the thyroid, brain or heart. With new multi-detector SPECT systems, convergent-beam geometry offers the ability to simultaneously obtain emission and transmission data necessary to quantify uptake of radiopharmaceutical distributions in the heart. The development of convergent-beam geometry in SPECT requires the integration of hardware and software. In considering hardware, the optimum detector system for cone-beam tomography is a system that satisfies the data sufficiency condition for which the scanning trajectory intersects any plane passing through the reconstructed region of interest. However, the major development of algorithms has been for the data insufficient case of single planar orbit acquisitions. The development of these algorithms have made possible the preliminary evaluation of this technology and the imaging of brain and heart are showing significant potential for the clinical application of cone-beam tomography. Presently, significant research activity is pursuing the development of algorithms for data acquisitions that satisfy the data sufficiency condition and that can be implemented easily and inexpensively on clinical SPECT systems.
- Published
- 1992
- Full Text
- View/download PDF
12. Cone beam tomography of the heart using single-photon emission-computed tomography.
- Author
-
Gullberg GT, Christian PE, Zeng GL, Datz FL, and Morgan HT
- Subjects
- Algorithms, Dipyridamole, Electronic Data Processing methods, Exercise Test, Filtration instrumentation, Humans, Mathematics, Models, Structural, Thallium Radioisotopes, Tomography, Emission-Computed, Single-Photon instrumentation, Heart diagnostic imaging, Tomography, Emission-Computed, Single-Photon methods
- Abstract
The authors evaluated cone beam single-photon emission-computed tomography (SPECT) of the heart. A new cone beam reconstruction algorithm was used to reconstruct data collected from "short scan" acquisitions (of slightly more than 180 degrees) of a detector anteriorally traversing a noncircular orbit. The less than 360 degrees acquisition was used to minimize the attenuation artifacts that result from reconstructing posterior projections of 201T1 emissions from the heart. The algorithm includes a new method for reconstructing truncated projections of background tissue activity that eliminates reconstruction ring artifacts. Phantom and patient results are presented which compare a high-resolution cone beam collimator (50-cm focal length; 6.0-mm full width at half maximum [FWHM] at 10 cm) to a low-energy general purpose (LEGP) parallel hole collimator (8.2-mm FWHM at 10 cm) which is 1.33 times more sensitive. The cone beam tomographic results are free of reconstruction artifacts and show improved spatial and contrast resolution over that obtained with the LEGP parallel hole collimator. The limited angular sampling restrictions and truncation problems associated with cone beam tomography do not deter from obtaining diagnostic information. However, even though these preliminary results are encouraging, a thorough clinical study is still needed to investigate the specificity and sensitivity of cone beam tomography.
- Published
- 1991
- Full Text
- View/download PDF
13. Orbit-related variation in spatial resolution as a source of artifactual defects in thallium-201 SPECT.
- Author
-
Maniawski PJ, Morgan HT, and Wackers FJ
- Subjects
- Humans, Models, Structural, Technology, Radiologic, Coronary Disease diagnostic imaging, Thallium Radioisotopes, Tomography, Emission-Computed, Single-Photon
- Abstract
The cause of 180-degree diametrical artifactual defects in clinical thallium-201 SPECT imaging was investigated using phantom simulation. This artifact was observed on SPECT images acquired with a "body contour" or "peanut" orbit. It was hypothesized that this artifact was caused by differences in spatial resolution that occur when the heart-to-detector distance changes employing noncircular orbits. To test this hypothesis, a series of planar static images of a normal cylindrical phantom was obtained at varying distances from the camera detector head. From these images, tomographic acquisition files were created that simulated tomographic data acquired with circular orbits and elliptical orbits. The reconstructed phantom short-axis slices showed no artifacts for circular orbits. However, for various elliptical orbits, significant regional nonuniformity, similar to the artifacts noted in patients, was observed. The degree of nonuniformity correlated with the long-short axis ratio of elliptical orbits (r = 0.98). In addition, circular orbits with the phantom in an eccentric position resulted in similar nonuniformities. It is concluded that a noncircular tomographic orbit can create characteristic artifacts on thallium-201 SPECT images. For rotational thallium 201 SPECT, a circular orbit with the heart in the center of rotation should be employed.
- Published
- 1991
14. Single photon emission computed tomography of the heart using cone beam geometry and noncircular detector rotation.
- Author
-
Gullberg GT, Zeng GS, Christian PE, Tsui BM, and Morgan HT
- Subjects
- Algorithms, Humans, Image Processing, Computer-Assisted, Mathematics, Models, Structural, Rotation, Computer Simulation, Heart diagnostic imaging, Models, Cardiovascular, Tomography, Emission-Computed, Single-Photon methods
- Published
- 1991
15. An improved method for estimating the entrance exposure in diagnostic radiographic examinations.
- Author
-
Zamenhof RG, Shahabi S, and Morgan HT
- Subjects
- Humans, Radiation Monitoring methods
- Abstract
There is currently a widespread consensus on the importance of monitoring patient radiation exposures during radiographic examinations. Diagnostic facilities under federal jurisdiction already legislate maximum patient exposure limits for various diagnostic radiologic examinations, while an increasing number of state legislatures have instituted such regulations. Compliance requires that institutions be capable of assessing each patient's entrance exposures. A method is proposed that would facilitate the acquisition of such patient exposure information in a relatively straightforward and accurate manner, requiring a minimum number of measurements and access to a suitable programmable calculator. A standardized set of exposure measurements obtained on an accurately calibrated three-phase radiographic unit has been fitted by an analytic function. The average accuracy of the fit between the limits of 40-140 kVp and 2.5- to 6.0-mm aluminum filtration was 0.3%. The concept of linear scaling was employed to allow the analytic function to accurately reproduce the exposure outputs of different radiographic units. Validation experiments on patients indicated that an overall accuracy of 10% can be expected when using well-calibrated radiographic equipment. The method described permits institutions to verify their compliance with federal and/or state regulations and to confirm that their radiation exposures are consistent with national averages.
- Published
- 1987
- Full Text
- View/download PDF
Catalog
Discovery Service for Jio Institute Digital Library
For full access to our library's resources, please sign in.