1. A smartphone-based multichannel magnetoelastic immunosensor for acute aortic dissection supplementary diagnosis.
- Author
-
Cao Y, Wang Q, Han M, Zhang Y, Yuan Z, Zhuo K, Zhang H, Xing Z, Jin H, and Zhao C
- Subjects
- Humans, Immunoassay methods, Immunoassay instrumentation, Fibrin Fibrinogen Degradation Products analysis, Myosin Heavy Chains analysis, Myosin Heavy Chains immunology, Acute Disease, Biomarkers blood, Biomarkers analysis, Elasticity, Smartphone, Aortic Dissection diagnosis, Biosensing Techniques instrumentation, Biosensing Techniques methods, C-Reactive Protein analysis
- Abstract
Some biomarkers of acute aortic dissection (AAD) can be used for the potential supplementary diagnosis of AAD, such as C-reactive protein (CRP), smooth muscle myosin heavy chain (SmMHC), and D-dimer (D-D). However, the current measurement methods for common markers primarily rely on sophisticated instruments. The operation process is complicated, and the reagents used are expensive. To provide chronic disease monitoring and home self-examination services for potential AAD patients in real time, we developed a smartphone-based multichannel magnetoelastic (ME) immunosensing device to detect protein levels. Our immunosensor reduced the aforementioned restrictions and demonstrated excellent performance for the supplementary diagnosis of AAD. In this paper, we successfully combined the intelligent terminal with the hardware system to sample the resonance frequency shift (RFS) on the multichannel ME immunosensor. According to the target detection objects with their respective antibodies in the immune binding response, multiple experiments were conducted to detect multiple groups of samples, and we found that a CRP concentration, a SmMHC concentration, and a D-D concentration in the range of 0.1-100μg/mL, 1-4ng/mL, and 0.25-5μg/mL were linearly proportional to the RFS of the ME immunosensor, respectively. For CRP, SmMHC, and D-D, the sensitivities were 13.37Hz/μg∙mL
-1 , 155.19Hz/ng∙mL-1 , and 332.72Hz/μg∙mL-1 , respectively, and the detection limits were 2.634×10-3 μg/mL, 1.155×10-2 ng/mL, and 3.687×10-3 μg/mL, respectively. The experiments demonstrated that the accuracy and stability of our device were comparable to those of the vector network analyzer (VNA, Calibration instrument)., Competing Interests: Declaration of competing interest There are no conflicts to declare., (Copyright © 2024 Elsevier B.V. All rights reserved.)- Published
- 2025
- Full Text
- View/download PDF