1. Motion‐insensitive susceptibility weighted imaging
- Author
-
Johan Berglund, Stefan Skare, Adam van Niekerk, Tim Sprenger, Henric Rydén, Enrico Avventi, and Ola Norbeck
- Subjects
Echo-Planar Imaging ,Computer science ,Pulse (signal processing) ,Image quality ,business.industry ,Rotation around a fixed axis ,Phase (waves) ,Brain ,Magnetic Resonance Imaging ,Signal ,Motion (physics) ,030218 nuclear medicine & medical imaging ,03 medical and health sciences ,0302 clinical medicine ,Susceptibility weighted imaging ,Humans ,Snapshot (computer storage) ,Radiology, Nuclear Medicine and imaging ,Computer vision ,Prospective Studies ,Artificial intelligence ,Artifacts ,business ,030217 neurology & neurosurgery ,Retrospective Studies - Abstract
Purpose To enable SWI that is robust to severe head movement. Methods Prospective motion correction using a markerless optical tracker was applied to all pulse sequences. Three-dimensional gradient-echo and 3D EPI were used as reference sequences, but were expected to be sensitive to motion-induced B0 changes, as the long TE required for SWI allows phase discrepancies to accumulate between shots. Therefore, 2D interleaved snapshot EPI was investigated for motion-robust SWI and compared with conventional 2D EPI. Repeated signal averages were retrospectively corrected for motion. The sequences were evaluated at 3 T through controlled motion experiments involving two cooperative volunteers and SWI of a tumor patient. Results The performed continuous head motion was in the range of 5-8° rotations. The image quality of the 3D sequences and conventional 2D EPI was poor unless the rotational motion axis was parallel to B0 . Interleaved snapshot EPI had minimal intraslice phase discrepancies due to its small temporal footprint. Phase inconsistency between signal averages was well tolerated due to the high-pass filter effect of the SWI processing. Interleaved snapshot EPI with prospective and retrospective motion correction demonstrated similar image quality, regardless of whether motion was present. Lesion depiction was equal to 3D EPI with matching resolution. Conclusion Susceptibility-based imaging can be severely corrupted by head movement despite accurate prospective motion correction. Interleaved snapshot EPI is a superior alternative for patients who are prone to move and offers SWI which is insensitive to motion when combined with prospective and retrospective motion correction.
- Published
- 2021
- Full Text
- View/download PDF