78 results on '"Raithel E"'
Search Results
2. Histological Validation Of The Textural Features From Quantitative MRI For Determination Of Cartilage Degeneration
- Author
-
Juras, V., primary, Toegel, S., additional, Hager, B., additional, Schreiner, M., additional, Janacova, V., additional, Heule, R., additional, Laurent, D., additional, Saxer, F., additional, Bieri, O., additional, Raithel, E., additional, Szomolanyi, P., additional, Fuchssteiner, C., additional, Weninger, W.J., additional, Windhager, R., additional, and Trattnig, S., additional
- Published
- 2023
- Full Text
- View/download PDF
3. CARTILAGE REGENERATION AFTER TREATMENT WITH LNA043, A NOVEL DISEASE-MODIFYING OSTEOARTHRITIS DRUG CANDIDATE: RESULTS FROM AN IMAGING-BASED PROOF-OF-CONCEPT TRIAL IN PATIENTS WITH FOCAL ARTICULAR CARTILAGE LESIONS IN THE KNEE
- Author
-
Saxer, F., primary, Laurent, D., additional, Scotti, C., additional, Juras, V., additional, Hacker, S., additional, Cole, B., additional, Pasa, L., additional, Lehovec, R., additional, Szomolanyi, P., additional, Raithel, E., additional, Praestgaard, J., additional, Gamba, F.L., additional, Jiménez, J.L., additional, Ramos, D.S., additional, Trattnig, S., additional, Roubenoff, R., additional, and Schieker, M., additional
- Published
- 2022
- Full Text
- View/download PDF
4. POS0277 ANABOLIC EFFECT OF LNA043, A NOVEL DISEASE-MODIFYING OSTEOARTHRITIS DRUG CANDIDATE: RESULTS FROM AN IMAGING-BASED PROOF-OF-CONCEPT TRIAL IN PATIENTS WITH FOCAL ARTICULAR CARTILAGE LESIONS
- Author
-
Trattnig, S., primary, Scotti, C., additional, Laurent, D., additional, Juras, V., additional, Hacker, S., additional, Cole, B., additional, Pasa, L., additional, Lehovec, R., additional, Szomolanyi, P., additional, Raithel, E., additional, Saxer, F., additional, Praestgaard, J., additional, La Gamba, F., additional, Jiménez, J. L., additional, Ramos, D. S., additional, Roubenoff, R., additional, and Schieker, M., additional
- Published
- 2021
- Full Text
- View/download PDF
5. Fully automated pipeline for quantitative MRI evaluation of knee articular cartilage for longitudinal OA trials
- Author
-
Juras, V., primary, Janáčová, V., additional, Szomolanyi, P., additional, Schreiner, M., additional, Laurent, D., additional, Scotti, C., additional, Raithel, E., additional, and Trattnig, S., additional
- Published
- 2021
- Full Text
- View/download PDF
6. High-Resolution Gadolinium-Enhanced MR Cisternography Using Compressed-Sensing T1 SPACE Technique for Detection of Intracranial CSF Leaks
- Author
-
Duman, I.E., primary, Demerath, T., additional, Stadler, A., additional, Elsheikh, S., additional, Raithel, E., additional, Forman, C., additional, Hildenbrand, T., additional, Shah, M., additional, Grauvogel, J., additional, Scheiwe, C., additional, Urbach, H., additional, and Meckel, S., additional
- Published
- 2020
- Full Text
- View/download PDF
7. Die „Salzburg-Moorfields-Collaborative-Glaucoma-Study“ (SMCGS): Das Konzept und erste Erfahrungen bei der Umsetzung
- Author
-
Mistlberger, Andrea, Sitte, Susanne, Ruckhofer, J., Raithel, E., Alzner, E., Grabner, G., and Wormald, R.
- Published
- 1998
- Full Text
- View/download PDF
8. Evaluation of an accelerated 3D SPACE sequence with compressed sensing and free-stop scan mode for imaging of the knee
- Author
-
Henninger, B., primary, Raithel, E., additional, Kranewitter, C., additional, Steurer, M., additional, Jaschke, W., additional, and Kremser, C., additional
- Published
- 2018
- Full Text
- View/download PDF
9. The involvement of the histamine degradation pathway by diamine oxidase in manifest gastrointestinal allergies
- Author
-
Raithel, M., Küfner, M., Ulrich, P., and Hahn<!-RID="h1"--><!-ID="h1" Correspondence to: M. Raithel-->, E. G.
- Published
- 1999
- Full Text
- View/download PDF
10. Regionale Veränderungen bei Myokardischämie — Eine tierexperimentelle Studie
- Author
-
van Ackern, K., Adler, M., Brückner, U. B., Buell, U., Haller, M., Mittmann, U., Ragaller, M., Raithel, E., Vetter, H., Wöllner, W., Bergmann, H., editor, Brückner, J. B., editor, Gemperle, M., editor, Henschel, W. F., editor, Mayrhofer, O., editor, Meßmer, K., editor, Peter, K., editor, Peter, Klaus, editor, Brown, Burnell R., editor, Martin, Eike, editor, and Norlander, Olof, editor
- Published
- 1986
- Full Text
- View/download PDF
11. Regional Changes During Myocardial Ischemia: An Animal Experimental Study
- Author
-
Van Ackern, K., Adler, M., Brückner, U. B., Buell, U., Haller, M., Mittmann, U., Ragaller, M., Raithel, E., Vetter, H., Wöllner, W., Bergmann, H., editor, Brückner, J. B., editor, Gemperle, M., editor, Henschel, W. F., editor, Mayrhofer, O., editor, Weβmer, K., editor, Peter, K., editor, Peter, Klaus, editor, Brown, Burnell R., editor, Martin, Eike, editor, and Norlander, Olof, editor
- Published
- 1987
- Full Text
- View/download PDF
12. High-Resolution Gadolinium-Enhanced MR Cisternography Using Compressed-Sensing T1 SPACE Technique for Detection of Intracranial CSF Leaks.
- Author
-
Duman, I. E., Demerath, T., Stadler, A., Elsheikh, S., Raithel, E., Forman, C., Hildenbrand, T., Shah, M., Grauvogel, J., Scheiwe, C., Urbach, H., and Meckel, S.
- Published
- 2021
- Full Text
- View/download PDF
13. Regional Changes During Myocardial Ischemia: An Animal Experimental Study
- Author
-
Ackern, K., primary, Adler, M., additional, Brückner, U. B., additional, Buell, U., additional, Haller, M., additional, Mittmann, U., additional, Ragaller, M., additional, Raithel, E., additional, Vetter, H., additional, and Wöllner, W., additional
- Published
- 1987
- Full Text
- View/download PDF
14. Regionale Veränderungen bei Myokardischämie — Eine tierexperimentelle Studie
- Author
-
Ackern, K., primary, Adler, M., additional, Brückner, U. B., additional, Buell, U., additional, Haller, M., additional, Mittmann, U., additional, Ragaller, M., additional, Raithel, E., additional, Vetter, H., additional, and Wöllner, W., additional
- Published
- 1986
- Full Text
- View/download PDF
15. Glass ionomer implants and tissue aluminum levels: an animal study
- Author
-
Hintschich, Cr, Raithel, E, Willekens, B, Craig, G, Bernatzky, G, Baldeschi, Lelio, and Collin, J. R. O.
- Published
- 1997
16. Intravenöses Salbutamol bei Frühgeborenen unter 1000g, Ergebnisse einer Pilotstudie
- Author
-
Flemmer, AW, primary, Raithel, E, additional, Kuscha, M, additional, Klemme, M, additional, Schulze, A, additional, and Thome, U, additional
- Published
- 2007
- Full Text
- View/download PDF
17. Der Effekt von Salbutamol auf die elektrische Impedanz der Lunge extrem Frühgeborener
- Author
-
Kuscha, M, primary, Raithel, E, additional, Klemme, M, additional, Schulze, A, additional, Thome, U, additional, and Flemmer, AW, additional
- Published
- 2007
- Full Text
- View/download PDF
18. Der Effekt von intravenös appliziertem Salbutamol auf die Aktivität des epithalialen Natriumkanals, gemessen als amiloridabhängiges Nasenpotential
- Author
-
Raithel, E, primary, Kuscha, M, additional, Klemme, M, additional, Schulze, A, additional, Thome, U, additional, and Flemmer, AW, additional
- Published
- 2007
- Full Text
- View/download PDF
19. Glas-lonomerzement und Aluminiumanreicherung im Körpergewebe
- Author
-
Hintschich, C., primary, Bematzky, G., additional, Raithel, E., additional, Willekens, B., additional, Craig, G., additional, and Collin, R., additional
- Published
- 1997
- Full Text
- View/download PDF
20. Glass-ionomer implants and tissue aluminum levels: an animal study
- Author
-
Hintschich, C. R., primary, Raithel, E., additional, Willekens, B., additional, Craig, G., additional, Bernatzky, G., additional, Baldeschi, L., additional, and Collin, J. R. O., additional
- Published
- 1997
- Full Text
- View/download PDF
21. Die Wertigkeit der hepatobiliären Funktionsszintigraphie mit 99mTc-Diaethyl-IDA
- Author
-
Tongendorff, J., Raithel, E., Büll, U., Grunst, J., Trumm, F., and Scherer, R.
- Published
- 1978
- Full Text
- View/download PDF
22. EFFECTS OF ISOFLURANE ON MYOCARDIAL ISCHEMIA IN DOGS
- Author
-
Ackern, K. V., primary, Adler, M., additional, Brückner, U. B., additional, Buell, U., additional, Haller, M., additional, Ragaller, M., additional, Raithel, E., additional, and Woellner, W., additional
- Published
- 1984
- Full Text
- View/download PDF
23. 3D-DESS MRI with CAIPIRINHA two- and fourfold acceleration for quantitatively assessing knee cartilage morphology.
- Author
-
Wen D, Zhou X, Hou B, Zhang Q, Raithel E, Wang Y, Wu G, and Li X
- Subjects
- Humans, Male, Female, Adult, Image Interpretation, Computer-Assisted methods, Signal-To-Noise Ratio, Middle Aged, Image Enhancement methods, Artifacts, Imaging, Three-Dimensional methods, Magnetic Resonance Imaging methods, Cartilage, Articular diagnostic imaging, Knee Joint diagnostic imaging, Knee Joint pathology
- Abstract
Objectives: This study aimed to assess the diagnostic image quality and compare the knee cartilage segmentation results using a controlled aliasing in parallel imaging results in higher acceleration (CAIPIRINHA)-accelerated 3D-dual echo steady-state (DESS) research package sequence in the knee., Materials and Methods: A total of 64 subjects underwent both two- and fourfold CAIPIRINHA-accelerated 3D-DESS and DESS without parallel acceleration technique of the knee on a 3.0 T system. Two musculoskeletal radiologists evaluated the images independently for image quality and diagnostic capability following randomization and anonymization. The consistency of automatic segmentation results between sequences was explored using an automatic knee cartilage segmentation research application. The descriptive statistics and inter-observer and inter-method concordance of various acceleration sequences were investigated. P values < .05 were considered significant., Results: For image quality evaluation, the image signal-to-noise ratio and contrast-to-noise ratio decreased with the decrease in scanning time. However, it is accompanied by the reduction of artifacts. Using 3D-DESS without parallel acceleration technique as the standard for cartilage grading diagnosisand the diagnostic agreement of two- and fourfold CAIPIRINHA-accelerated 3D-DESS was good, kappa value was 0.860 (P < .001) and 0.804 (p < 0.001), respectively. Regarding cartilage defects, the sensitivity and specificity of the twofold acceleration 3D-CAIPIRINHA-DESS were 95.56% and 97.70%, and the fourfold CAIPIRINHA-accelerated 3D-DESS were 91.49% and 97.65%, respectively. The intraclass correlation coefficients of various sequences in cartilage segmentation were almost all greater than 0.9., Conclusion: The CAIPIRINHA-accelerated 3D-DESS sequence maintained comparable diagnostic and segmentations performance of knee cartilage after a 60% scan time reduction., (© 2024. The Author(s), under exclusive licence to International Skeletal Society (ISS).)
- Published
- 2024
- Full Text
- View/download PDF
24. A reproducibility study of knee cartilage volume and thickness values derived by fully automatic segmentation based on three-dimensional dual-echo in steady state data from 1.5 T and 3 T magnetic resonance imaging.
- Author
-
Zhang R, Zhou X, Raithel E, Ren C, Zhang P, Li J, Bai L, and Zhao J
- Subjects
- Humans, Reproducibility of Results, Knee Joint diagnostic imaging, Magnetic Resonance Imaging methods, Software, Cartilage, Articular diagnostic imaging
- Abstract
Objective: To evaluate the repeatability of cartilage volume and thickness values at 1.5 T MRI using a fully automatic cartilage segmentation method and reproducibility of the method between 1.5 T and 3 T data., Methods: The study included 20 knee joints from 10 healthy subjects with each subject having undergone double-knee MRI. All knees were scanned at 1.5 T and 3 T MR scanners using a three-dimensional (3D) high-resolution dual-echo in steady state (DESS) sequence. Cartilage volume and thickness of 21 subregions were quantified using a fully automatic cartilage segmentation research application (MR Chondral Health, version 3.0, Siemens Healthcare, Erlangen, Germany). The volume and thickness values derived from fully automatically computed segmentation masks were analyzed for the scan-rescan data from the same volunteers. The accuracy of the automatic segmentation of the cartilage in 1.5 T images was evaluated by the dice similarity coefficient (DSC) and Hausdorff distance (HD) using the manually corrected segmentation as a reference. The volume and thickness values calculated from 1.5 T and 3 T were also compared., Results: No statistically significant differences were found for cartilage thickness or volume across all subregions between the scan-rescanned data at 1.5 T (P > 0.05). The mean DSC between the fully automatic and manually corrected knee cartilage segmentation contours at 1.5 T was 0.9946. The average value of HD was 2.41 mm. Overall, there was no statistically significant difference in the cartilage volume or thickness in most-subregions between the two field strengths (P > 0.05) except for the medial region of femur and tibia. Bland-Altman plot and intraclass correlation coefficient (ICC) showed high consistency between results obtained based on same and different scanning sequences., Conclusion: The cartilage segmentation software had high repeatability for DESS images obtained from the same device. In addition, the overall reproducibility of the images obtained from equipment of two different field strengths was satisfactory., (© 2023. The Author(s), under exclusive licence to European Society for Magnetic Resonance in Medicine and Biology (ESMRMB).)
- Published
- 2024
- Full Text
- View/download PDF
25. Deep Learning Diagnosis and Classification of Rotator Cuff Tears on Shoulder MRI.
- Author
-
Lin DJ, Schwier M, Geiger B, Raithel E, von Busch H, Fritz J, Kline M, Brooks M, Dunham K, Shukla M, Alaia EF, Samim M, Joshi V, Walter WR, Ellermann JM, Ilaslan H, Rubin D, Winalski CS, and Recht MP
- Subjects
- Humans, Shoulder, Rotator Cuff pathology, Magnetic Resonance Imaging methods, Rotator Cuff Injuries diagnostic imaging, Rotator Cuff Injuries pathology, Deep Learning
- Abstract
Background: Detection of rotator cuff tears, a common cause of shoulder disability, can be time-consuming and subject to reader variability. Deep learning (DL) has the potential to increase radiologist accuracy and consistency., Purpose: The aim of this study was to develop a prototype DL model for detection and classification of rotator cuff tears on shoulder magnetic resonance imaging into no tear, partial-thickness tear, or full-thickness tear., Materials and Methods: This Health Insurance Portability and Accountability Act-compliant, institutional review board-approved study included a total of 11,925 noncontrast shoulder magnetic resonance imaging scans from 2 institutions, with 11,405 for development and 520 dedicated for final testing. A DL ensemble algorithm was developed that used 4 series as input from each examination: fluid-sensitive sequences in 3 planes and a sagittal oblique T1-weighted sequence. Radiology reports served as ground truth for training with categories of no tear, partial tear, or full-thickness tear. A multireader study was conducted for the test set ground truth, which was determined by the majority vote of 3 readers per case. The ensemble comprised 4 parallel 3D ResNet50 convolutional neural network architectures trained via transfer learning and then adapted to the targeted domain. The final tear-type prediction was determined as the class with the highest probability, after averaging the class probabilities of the 4 individual models., Results: The AUC overall for supraspinatus, infraspinatus, and subscapularis tendon tears was 0.93, 0.89, and 0.90, respectively. The model performed best for full-thickness supraspinatus, infraspinatus, and subscapularis tears with AUCs of 0.98, 0.99, and 0.95, respectively. Multisequence input demonstrated higher AUCs than single-sequence input for infraspinatus and subscapularis tendon tears, whereas coronal oblique fluid-sensitive and multisequence input showed similar AUCs for supraspinatus tendon tears. Model accuracy for tear types and overall accuracy were similar to that of the clinical readers., Conclusions: Deep learning diagnosis of rotator cuff tears is feasible with excellent diagnostic performance, particularly for full-thickness tears, with model accuracy similar to subspecialty-trained musculoskeletal radiologists., Competing Interests: Conflicts of interest and sources of funding: Industry collaboration with Siemens (authors' expertise as above), provision of funding for multireader study ground truth research reads., (Copyright © 2023 Wolters Kluwer Health, Inc. All rights reserved.)
- Published
- 2023
- Full Text
- View/download PDF
26. Analysis of Knee Joint Injury Caused by Physical Training of Freshmen Students Based on 3T MRI and Automatic Cartilage Segmentation Technology: A Prospective Study.
- Author
-
Liu L, Liu H, Zhen Z, Zheng Y, Zhou X, Raithel E, Du J, Hu Y, Chen W, and Hu X
- Subjects
- Humans, Knee Joint diagnostic imaging, Magnetic Resonance Imaging methods, Male, Prospective Studies, Students, Cartilage, Articular diagnostic imaging, Knee Injuries diagnostic imaging
- Abstract
Background: The differential effects of various exercises on knee joint injury have not been well documented. Improper physical training can cause irreversible damage to the knee joint. MRI is generally used to precisely analyze morphological and biochemical changes in the knee cartilage. We compared the effects of long-walking and regular daily physical training on acute and chronic knee joint injuries as well as cartilage structure in freshmen students., Methods: A total of 23 young male college freshmen were recruited to participate in an 8-day 240 km long distance walk and a one-year daily training. 3D-DESSwe, 2D T
2 mapping, DIXON, and T1WI of the right knee joint were performed using the MAGNETOM Spectra 3T MR scanner. The injury of meniscus, bone marrow edema, ligaments and joint effusion is graded. Cartilage volume, thickness and T2 values of 21 sub-regions of the knee cartilage were estimated using automatic cartilage segmentation prototype software. Friedman's test and Wilcoxon paired rank-sum test were used to compare quantitative indices of knee cartilage in three groups., Results: The injury to the medial meniscus and anterior cruciate ligament of the knee joint, joint effusion, and bone marrow edema was significantly higher in the long-walking group compared to the baseline and daily groups. Furthermore, injury to the lateral meniscus was significantly worse in the long-walking group compared to the baseline group but was significantly better in the daily group compared to the baseline group. No significant changes to the posterior cruciate ligament were observed among the three groups. Knee cartilage volume was significantly increased, mainly in the stress surface of the femur, patella, and the lateral area of the tibial plateau. Regular daily training did not significantly change the thickness of the knee cartilage. Conversely, knee cartilage thickness decreased in the long-walking group, especially in the medial and lateral areas of the femur and tibial plateau. Moreover, no significant changes were observed in the knee cartilage volume of the long-walking group. Both long-walking and daily groups showed reduced T2 values of the knee joint compared to the baseline., Conclusion: Among freshmen students and the training of this experimental intensity, our results show that regular daily training does not cause high-level injury to the knee joint, but improve the knee joint function adaptability by increasing cartilage volume. Moreover, knee injury caused by short-term long walking can be reversible., Competing Interests: XZ is an employee of Siemens Healthineers Ltd and ER is an employee of Siemens Healthcare GmbH. The remaining authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest., (Copyright © 2022 Liu, Liu, Zhen, Zheng, Zhou, Raithel, Du, Hu, Chen and Hu.)- Published
- 2022
- Full Text
- View/download PDF
27. Vasa vasorum of proximal cerebral arteries after dural crossing - potential imaging confounder in diagnosing intracranial vasculitis in elderly subjects on black-blood MRI.
- Author
-
Guggenberger KV, Torre GD, Ludwig U, Vogel P, Weng AM, Vogt ML, Fröhlich M, Schmalzing M, Raithel E, Forman C, Urbach H, Meckel S, and Bley TA
- Subjects
- Aged, Cerebral Arteries, Humans, Magnetic Resonance Angiography, Magnetic Resonance Imaging, Vasa Vasorum diagnostic imaging, Vasculitis
- Abstract
Objectives: Vessel wall enhancement (VWE) may be commonly seen on MRI images of asymptomatic subjects. This study aimed to characterize the VWE of the proximal internal carotid (ICA) and vertebral arteries (VA) in a non-vasculitic elderly patient cohort., Methods: Cranial MRI scans at 3 Tesla were performed in 43 patients (aged ≥ 50 years) with known malignancy for exclusion of cerebral metastases. For vessel wall imaging (VWI), a high-resolution compressed-sensing black-blood 3D T1-weighted fast (turbo) spin echo sequence (T1 CS-SPACE prototype) was applied post gadolinium with an isotropic resolution of 0.55 mm. Bilateral proximal intradural ICA and VA segments were evaluated for presence, morphology, and longitudinal extension of VWE., Results: Concentric VWE of the proximal intradural ICA was found in 13 (30%) patients, and of the proximal intradural VA in 39 (91%) patients. Mean longitudinal extension of VWE after dural entry was 13 mm in the VA and 2 mm in the ICA. In 14 of 39 patients (36%) with proximal intradural VWE, morphology of VWE was suggestive of the mere presence of vasa vasorum. In 25 patients (64 %), morphology indicated atherosclerotic lesions in addition to vasa vasorum., Conclusions: Vasa vasorum may account for concentric VWE within the proximal 2 mm of the ICA and 13 mm of the VA after dural entry in elderly subjects. Concentric VWE in these locations should not be confused with large artery vasculitis. Distal to these segments, VWE may be more likely related to pathologic conditions such as vasculitis., Key Points: • Vasa vasorum may account for concentric VWE within the proximal 2 mm of the ICA and 13 mm of the VA after dural entry in non-vasculitic elderly people. • Concentric enhancement within the proximal 2 mm of the intradural ICA and within the proximal 13 mm of the intradural VA portions should not be misinterpreted as vasculitis. • Distal of this, VWE is likely related to pathologic conditions, in case of concentric VWE suggestive of vasculitis., (© 2021. The Author(s).)
- Published
- 2022
- Full Text
- View/download PDF
28. Clinical validation of the use of prototype software for automatic cartilage segmentation to quantify knee cartilage in volunteers.
- Author
-
Zhang P, Zhang RX, Chen XS, Zhou XY, Raithel E, Cui JL, and Zhao J
- Subjects
- Humans, Knee, Knee Joint diagnostic imaging, Magnetic Resonance Imaging, Software, Volunteers, Cartilage, Articular diagnostic imaging
- Abstract
Background: The cartilage segmentation algorithms make it possible to accurately evaluate the morphology and degeneration of cartilage. There are some factors (location of cartilage subregions, hydrarthrosis and cartilage degeneration) that may influence the accuracy of segmentation. It is valuable to evaluate and compare the accuracy and clinical value of volume and mean T2* values generated directly from automatic knee cartilage segmentation with those from manually corrected results using prototype software., Method: Thirty-two volunteers were recruited, all of whom underwent right knee magnetic resonance imaging examinations. Morphological images were obtained using a three-dimensional (3D) high-resolution Double-Echo in Steady-State (DESS) sequence, and biochemical images were obtained using a two-dimensional T2* mapping sequence. Cartilage score criteria ranged from 0 to 2 and were obtained using the Whole-Organ Magnetic Resonance Imaging Score (WORMS). The femoral, patellar, and tibial cartilages were automatically segmented and divided into subregions using the post-processing prototype software. Afterwards, all the subregions were carefully checked and manual corrections were done where needed. The dice coefficient correlations for each subregion by the automatic segmentation were calculated., Results: Cartilage volume after applying the manual correction was significantly lower than automatic segmentation (P < 0.05). The percentages of the cartilage volume change for each subregion after manual correction were all smaller than 5%. In all the subregions, the mean T2* relaxation time within manual corrected subregions was significantly lower than in regions after automatic segmentation (P < 0.05). The average time for the automatic segmentation of the whole knee was around 6 min, while the average time for manual correction of the whole knee was around 27 min., Conclusions: Automatic segmentation of cartilage volume has a high dice coefficient correlation and it can provide accurate quantitative information about cartilage efficiently without individual bias. Advances in knowledge: Magnetic resonance imaging is the most promising method to detect structural changes in cartilage tissue. Unfortunately, due to the structure and morphology of the cartilages obtaining accurate segmentations can be problematic. There are some factors (location of cartilage subregions, hydrarthrosis and cartilage degeneration) that may influence segmentation accuracy. We therefore assessed the factors that influence segmentations error., (© 2021. The Author(s).)
- Published
- 2022
- Full Text
- View/download PDF
29. Reproducibility of an Automated Quantitative MRI Assessment of Low-Grade Knee Articular Cartilage Lesions.
- Author
-
Juras V, Szomolanyi P, Schreiner MM, Unterberger K, Kurekova A, Hager B, Laurent D, Raithel E, Meyer H, and Trattnig S
- Subjects
- Humans, Knee, Knee Joint diagnostic imaging, Magnetic Resonance Imaging methods, Reproducibility of Results, Cartilage, Articular diagnostic imaging, Cartilage, Articular pathology
- Abstract
Objective: The goal of this study was to assess the reproducibility of an automated knee cartilage segmentation of 21 cartilage regions with a model-based algorithm and to compare the results with manual segmentation., Design: Thirteen patients with low-grade femoral cartilage defects were included in the study and were scanned twice on a 7-T magnetic resonance imaging (MRI) scanner 8 days apart. A 3-dimensional double-echo steady-state (3D-DESS) sequence was used to acquire MR images for automated cartilage segmentation, and T2-mapping was performed using a 3D triple-echo steady-state (3D-TESS) sequence. Cartilage volume, thickness, and T2 and texture features were automatically extracted from each knee for each of the 21 subregions. DESS was used for manual cartilage segmentation and compared with automated segmentation using the Dice coefficient. The reproducibility of each variable was expressed using standard error of measurement (SEM) and smallest detectable change (SDC)., Results: The Dice coefficient for the similarity between manual and automated segmentation ranged from 0.83 to 0.88 in different cartilage regions. Test-retest analysis of automated cartilage segmentation and automated quantitative parameter extraction revealed excellent reproducibility for volume measurement (mean SDC for all subregions of 85.6 mm
3 ), for thickness detection (SDC = 0.16 mm) and also for T2 values (SDC = 2.38 ms) and most gray-level co-occurrence matrix features (SDC = 0.1 a.u.)., Conclusions: The proposed technique of automated knee cartilage evaluation based on the segmentation of 3D MR images and correlation with T2 mapping provides highly reproducible results and significantly reduces the segmentation effort required for the analysis of knee articular cartilage in longitudinal studies.- Published
- 2021
- Full Text
- View/download PDF
30. Intracranial vessel wall imaging framework - Data acquisition, processing, and visualization.
- Author
-
Guggenberger K, Krafft AJ, Ludwig U, Raithel E, Forman C, Meckel S, Hennig J, Bley TA, and Vogel P
- Subjects
- Humans, Magnetic Resonance Angiography, Magnetic Resonance Imaging, Cerebrovascular Disorders diagnostic imaging, Imaging, Three-Dimensional
- Abstract
Objective: Assessment of vessel walls is an integral part in diagnosis and disease monitoring of vascular diseases such as vasculitis. Vessel wall imaging (VWI), in particular of intracranial arteries, is the domain of Magnetic Resonance Imaging (MRI) - but still remains a challenge. The tortuous anatomy of intracranial arteries and the need for high resolution within clinically acceptable scan times require special technical conditions regarding the hardware and software environments., Materials and Methods: In this work a dedicated framework for intracranial VWI is presented offering an optimized, black-blood 3D T1-weighted post-contrast Compressed Sensing (CS)-accelerated MRI sequence prototype combined with dedicated 3D-GUI supported post-processing tool for the CPR visualization of tortuous arbitrary vessel structures., Results: Using CS accelerated MRI sequence, the scanning time for high-resolution 3D black-blood CS-space data could be reduced to under 10 min. These data are adequate for a further processing to extract straightened visualizations (curved planar reformats - CPR). First patient data sets could be acquired in clinical environment., Conclusion: A highly versatile framework for VWI visualization was demonstrated utilizing a post-processing tool to extract CPR reformats from high-resolution 3D black-blood CS-SPACE data, enabling simplified and optimized assessment of intracranial arteries in intracranial vascular disorders, especially in suspected intracranial vasculitis, by stretching their tortuous course. The processing time from about 15-20 min per patient (data acquisition and further processing) allows the integration into clinical routine., (Copyright © 2021 Elsevier Inc. All rights reserved.)
- Published
- 2021
- Full Text
- View/download PDF
31. Quantitative measurement of cartilage volume with automatic cartilage segmentation in knee osteoarthritis.
- Author
-
Hou W, Zhao J, He R, Li J, Ou Y, Du M, Xiong X, Xie B, Li L, Zhou X, Zuo P, Raithel E, Zhang Z, and Chen W
- Subjects
- Germany, Humans, Knee Joint diagnostic imaging, Magnetic Resonance Imaging, Reproducibility of Results, Tibia diagnostic imaging, Cartilage, Articular diagnostic imaging, Osteoarthritis, Knee diagnostic imaging
- Abstract
Purpose: To determine the reproducibility of the automatic cartilage segmentation method using a prototype KneeCaP software (version 1.3; Siemens Healthcare, Erlangen, Germany) and to compare the difference in cartilage volume (CV) between the normal knee joint and knee osteoarthritis (KOA) of different degrees by using the above software., Materials and Methods: The study included 62 subjects with knee OA and 29 healthy control subjects. The cartilage lesion patients were divided into a mild-to-moderate OA group (n = 29) and severe OA group (n = 33). Automatic cartilage segmentation was performed on all the subjects, and among them, 19 knee cases were randomly selected to also do the manual cartilage segmentation. Statistical significance was determined with one-way analysis of variance (ANOVA), intraclass correlation coefficient (ICC), and Pearson correlation coefficient. Automatic segmentation was compared with the manual one. The relative cartilage volume percentages of the femur, tibia, and patella in the normal control/mild-to-moderate/severe OA groups were assessed., Results: Comparing the cartilage volumes derived by manual and automatic segmentation, the ICC value for the knee joint, patella, femur, or tibia was 0.784, 0.815, 0.740, and 0.797. The relative cartilage volume percentages of the femur, tibia, and patella in the normal control/mild-to-moderate/severe OA groups were 57.28%/59.30%/62.45% (femur), 25.35%/23.46%/21.84% (tibia), and 17.37%/17.24%/15.71% (patella), respectively. Compared with the normal control group, the relative tibia cartilage volume percentage was lower in the mild-to-moderate OA group and the severe OA group. Corresponding index showed a similar difference between the mild-to-moderate OA group and the severe OA group (p < 0.001)., Conclusion: This study demonstrated that the relative cartilage volume percentage is correlated with the semi-quantitative systems and may be a preferred outcome measure in clinical studies of OA. Automatic cartilage segmentation using KneeCaP delivered reliable results on high-spatial-resolution 3 T MR images for the healthy, mild-moderate OA patients. Key Points • The cartilage automatic segmentation has excellent reproducibility and was not affected by inter-observer variation. • The relative cartilage volume percentage is correlated with the semi-quantitative systems and may be a preferred outcome measure in clinical studies of OA.
- Published
- 2021
- Full Text
- View/download PDF
32. High-resolution Compressed-sensing T1 Black-blood MRI : A New Multipurpose Sequence in Vascular Neuroimaging?
- Author
-
Guggenberger K, Krafft AJ, Ludwig U, Vogel P, Elsheik S, Raithel E, Forman C, Dovi-Akué P, Urbach H, Bley T, and Meckel S
- Subjects
- Artifacts, Humans, Imaging, Three-Dimensional, Magnetic Resonance Imaging, Motion, Magnetic Resonance Angiography, Neuroimaging
- Abstract
Background and Purpose: In vasculopathies of the central nervous system, reliable and timely diagnosis is important against the background of significant morbidity and sequelae in cases of incorrect diagnosis or delayed treatment. Magnetic resonance imaging (MRI) plays a major role in the detection and monitoring of intracranial and extracranial vascular pathologies of different etiologies, in particular for evaluation of the vessel wall in addition to luminal information, thus allowing differentiation between various vasculopathies. Compressed-sensing black-blood MRI combines high image quality with relatively short acquisition time and offers promising potential in the context of neurovascular vessel wall imaging in clinical routine. This case review gives an overview of its application in the diagnosis of various intracranial and extracranial entities., Methods: An optimized high-resolution compressed-sensing black-blood 3D T1-weighted fast (turbo) spin echo technique (T1 CS-SPACE prototype) precontrast and postcontrast application at 3T was used for the evaluation of various vascular conditions in neuroradiology., Results: In this article seven cases of intracranial and extracranial arterial and venous vasculopathies with representative imaging findings in high-resolution compressed-sensing black-blood MRI are presented., Conclusion: High-resolution 3D T1 CS-SPACE black-blood MRI is capable of imaging various vascular entities in high detail with whole head coverage and low susceptibility for motion artifacts and within acceptable scan times. It represents a highly versatile, non-invasive technique for the visualization and differentiation of a wide variety of neurovascular arterial and venous disorders.
- Published
- 2021
- Full Text
- View/download PDF
33. High-Resolution Gadolinium-Enhanced MR Cisternography Using Compressed-Sensing T1 SPACE Technique for Detection of Intracranial CSF Leaks.
- Author
-
Duman IE, Demerath T, Stadler A, Elsheikh S, Raithel E, Forman C, Hildenbrand T, Shah M, Grauvogel J, Scheiwe C, Urbach H, and Meckel S
- Subjects
- Adult, Cerebrospinal Fluid Rhinorrhea surgery, Female, Gadolinium, Humans, Imaging, Three-Dimensional methods, Male, Middle Aged, Cerebrospinal Fluid Rhinorrhea diagnostic imaging, Magnetic Resonance Imaging methods, Neuroimaging methods
- Abstract
In patients with CSF rhinorrhea, accurate identification of the CSF leakage site is crucial for surgical planning. We describe the application of a novel gadolinium-enhanced high-resolution 3D compressed-sensing T1 SPACE technique for MR cisternography and compare findings with CT cisternography and intraoperative results. In our pilot experience with 7 patients, precise detection of CSF leaks was feasible using compressed-sensing T1 SPACE, which appeared to be superior to CT cisternography., (© 2021 by American Journal of Neuroradiology.)
- Published
- 2021
- Full Text
- View/download PDF
34. Surveillance of abdominal aortic aneurysm using accelerated 3D non-contrast black-blood cardiovascular magnetic resonance with compressed sensing (CS-DANTE-SPACE).
- Author
-
Zhu C, Cao L, Wen Z, Ahn S, Raithel E, Forman C, Hope M, and Saloner D
- Subjects
- Aged, Aorta, Abdominal physiopathology, Aortic Aneurysm, Abdominal physiopathology, Humans, Male, Predictive Value of Tests, Reproducibility of Results, Time Factors, Workflow, Aorta, Abdominal diagnostic imaging, Aortic Aneurysm, Abdominal diagnostic imaging, Imaging, Three-Dimensional, Magnetic Resonance Angiography
- Abstract
Background: 3D non-contrast high-resolution black-blood cardiovascular magnetic resonance (CMR) (DANTE-SPACE) has been used for surveillance of abdominal aortic aneurysm (AAA) and validated against computed tomography (CT) angiography. However, it requires a long scan time of more than 7 min. We sought to develop an accelerated sequence applying compressed sensing (CS-DANTE-SPACE) and validate it in AAA patients undergoing surveillance., Methods: Thirty-eight AAA patients (all males, 73 ± 6 years) under clinical surveillance were recruited for this study. All patients were scanned with DANTE-SPACE (scan time 7:10 min) and CS-DANTE-SPACE (scan time 4:12 min, a reduction of 41.4%). Nine 9 patients were scanned more than 2 times. In total, 50 pairs of images were available for comparison. Two radiologists independently evaluated the image quality on a 1-4 scale, and measured the maximal diameter of AAA, the intra-luminal thrombus (ILT) and lumen area, ILT-to-muscle signal intensity ratio, and the ILT-to-lumen contrast ratio. The sharpness of the aneurysm inner/outer boundaries was quantified., Results: CS-DANTE-SPACE achieved comparable image quality compared with DANTE-SPACE (3.15 ± 0.67 vs. 3.03 ± 0.64, p = 0.06). There was excellent agreement between results from the two sequences for diameter/area and ILT ratio measurements (ICCs> 0.85), and for quantifying growth rate (3.3 ± 3.1 vs. 3.3 ± 3.4 mm/year, ICC = 0.95.) CS-DANTE-SPACE showed a higher ILT-to-lumen contrast ratio (p = 0.01) and higher sharpness than DANTE-SPACE (p = 0.002). Both sequences had excellent inter-reader reproducibility for quantitative measurements (ICC > 0.88)., Conclusion: CS-DANTE-SPACE can reduce scan time while maintaining image quality for AAA imaging. It is a promising tool for the surveillance of patients with AAA disease in the clinical setting.
- Published
- 2019
- Full Text
- View/download PDF
35. Highly-accelerated volumetric brain examination using optimized wave-CAIPI encoding.
- Author
-
Polak D, Cauley S, Huang SY, Longo MG, Conklin J, Bilgic B, Ohringer N, Raithel E, Bachert P, Wald LL, and Setsompop K
- Subjects
- Adult, Aged, Aged, 80 and over, Artifacts, Female, Humans, Male, Middle Aged, Organ Size, Prospective Studies, Reproducibility of Results, Single-Blind Method, Young Adult, Brain diagnostic imaging, Brain pathology, Brain Diseases diagnostic imaging, Brain Diseases pathology, Image Interpretation, Computer-Assisted methods, Magnetic Resonance Imaging methods
- Abstract
Background: Rapid volumetric imaging protocols could better utilize limited scanner resources., Purpose: To develop and validate an optimized 6-minute high-resolution volumetric brain MRI examination using Wave-CAIPI encoding., Study Type: Prospective., Population/subjects: Ten healthy subjects and 20 patients with a variety of intracranial pathologies., Field Strength/sequence: At 3 T, MPRAGE, T
2 -weighted SPACE, SPACE FLAIR, and SWI were acquired at 9-fold acceleration using Wave-CAIPI and for comparison at 2-4-fold acceleration using conventional GRAPPA., Assessment: Extensive simulations were performed to optimize the Wave-CAIPI protocol and minimize both g-factor noise amplification and potential T1 /T2 blurring artifacts. Moreover, refinements in the autocalibrated reconstruction of Wave-CAIPI were developed to ensure high-quality reconstructions in the presence of gradient imperfections. In a randomized and blinded fashion, three neuroradiologists assessed the diagnostic quality of the optimized 6-minute Wave-CAIPI exam and compared it to the roughly 3× slower GRAPPA accelerated protocol using both an individual and head-to-head analysis., Statistical Test: A noninferiority test was used to test whether the diagnostic quality of Wave-CAIPI was noninferior to the GRAPPA acquisition, with a 15% noninferiority margin., Results: Among all sequences, Wave-CAIPI achieved negligible g-factor noise amplification (gavg ≤ 1.04) and burring artifacts from T1 /T2 relaxation. Improvements of our autocalibration approach for gradient imperfections enabled increased robustness to gradient mixing imperfections in tilted-field of view (FOV) prescriptions as well as variations in gradient and analog-to-digital converter (ADC) sampling rates. In the clinical evaluation, Wave-CAIPI achieved similar mean scores when compared with GRAPPA (MPRAGE: ØW = 4.03, ØG = 3.97; T2 w SPACE: ØW = 4.00, ØG = 4.00; SPACE FLAIR: ØW = 3.97, ØG = 3.97; SWI: ØW = 3.93, ØG = 3.83) and was statistically noninferior (N = 30, P < 0.05 for all sequences)., Data Conclusion: The proposed volumetric brain exam retained comparable image quality when compared with the much longer conventional protocol., Level of Evidence: 2 Technical Efficacy: Stage 1 J. Magn. Reson. Imaging 2019;50:961-974., (© 2019 International Society for Magnetic Resonance in Medicine.)- Published
- 2019
- Full Text
- View/download PDF
36. 10-Min 3D Turbo Spin Echo MRI of the Knee in Children: Arthroscopy-Validated Accuracy for the Diagnosis of Internal Derangement.
- Author
-
Fritz J, Ahlawat S, Fritz B, Thawait GK, Stern SE, Raithel E, Klyce W, and Lee RJ
- Subjects
- Adolescent, Child, Child, Preschool, Female, Humans, Image Processing, Computer-Assisted, Male, Observer Variation, Prospective Studies, Reproducibility of Results, Sensitivity and Specificity, Treatment Outcome, Arthroscopy, Imaging, Three-Dimensional, Knee diagnostic imaging, Knee Injuries diagnostic imaging, Magnetic Resonance Imaging
- Abstract
Background: Ten-minute MRI of the pediatric knee can add value through increased cost-effectiveness and decreased sedation needs but requires validation of its clinical efficacy., Purpose: To determine the arthroscopy-based diagnostic accuracy and interreader reliability of 10-min 3D Controlled Aliasing In Parallel Imaging Results In Higher Acceleration (CAIPIRINHA) turbo spin echo (TSE) MRI with two isotropic pulse sequences for the diagnosis of internal derangement in children with painful knee conditions., Study Type: Prospective., Subjects: Sixty children., Field Strength/sequence: 3T, gradient echo-based scout with automatic anatomical landmark recognition and plane prescription, 3D CAIPIRINHA SPACE TSE., Assessment: Three fellowship-trained musculoskeletal radiologists evaluated the MRI studies independently and resolved discrepancies through consensus. Outcome variables included image quality, motion artifacts, meniscal abnormalities, anterior and posterior cruciate ligament tears, and cartilage lesions. Arthroscopic surgery served as the standard of reference, which was performed after 37 (range, 1-143) days post-MRI., Statistical Tests: Diagnostic accuracy analysis of MRI with arthroscopic surgery as the standard of reference. Reliability analysis through calculation of interreader agreements with kappa statistics., Results: All studies were suitable for diagnostic interpretation with good-to-very-good image quality ratings and little-to-no motion degradation ratings in the majority of cases. The sensitivities/specificities/accuracies of 3D CAIPIRINHA TSE MRI were 0.93/0.96/0.94 for 15/60 (25%) medial meniscal tears, 0.95/0.92/0.94 for 21/60 (35%) lateral meniscal tears, 0.83/1.00/0.92 for 6/60 (17%) discoid menisci, 1.00/0.98/0.99 for 16/60 (27%) anterior cruciate ligament tears, 1.0/1.0/1.0 for 2/60 (3%) posterior cruciate ligament tears, 1.00/1.00/1.00 for 5/60 (8%) osteochondritis dissecans lesions, 0.71/0.96/0.84 for 48 (13%) defects in 360 cartilage segments, and 0.85/0.97/0.91 overall. The interreader agreements were overall good-to-very-good (kappa, 0.72-1.00)., Data Conclusion: The clinical use of 10-min 3D CAIPIRINHA TSE MRI of the knee in children with painful knee conditions yields an overall high arthroscopy-validated diagnostic accuracy of 91% and good-to-very good interreader reliability for the diagnosis of internal knee derangements., Level of Evidence: 1 Technical Efficacy: Stage 6 J. Magn. Reson. Imaging 2019;49:e139-e151., (© 2018 International Society for Magnetic Resonance in Medicine.)
- Published
- 2019
- Full Text
- View/download PDF
37. CAIPIRINHA-accelerated 10-min 3D TSE MRI of the ankle for the diagnosis of painful ankle conditions: Performance evaluation in 70 patients.
- Author
-
Fritz B, Bensler S, Thawait GK, Raithel E, Stern SE, and Fritz J
- Subjects
- Adolescent, Adult, Aged, Ankle, Arthralgia diagnostic imaging, Cartilage, Articular diagnostic imaging, Cartilage, Articular injuries, Female, Humans, Imaging, Three-Dimensional methods, Ligaments, Articular diagnostic imaging, Ligaments, Articular injuries, Magnetic Resonance Imaging methods, Male, Middle Aged, Reproducibility of Results, Tendon Injuries diagnostic imaging, Young Adult, Ankle Injuries diagnostic imaging, Ankle Joint diagnostic imaging, Joint Diseases diagnostic imaging
- Abstract
Objectives: To test the hypothesis that MRI of the ankle with a 10-min 3D CAIPIRINHA SPACE TSE protocol is at least equivalent for the detection of painful conditions when compared to a 20-min 2D TSE standard of reference protocol., Methods: Following institutional review board approval and informed consent, 70 symptomatic subjects underwent 3T MRI of the ankle. Six axial, sagittal and coronal intermediate-weighted (IW) and fat-saturated T2-weighted (T2FS) 2D TSE (total acquisition time, 20 min), and two sagittal isotropic IW and T2FS 3D CAIPIRINHA TSE (10 min) pulse sequence prototypes were obtained. Following randomization and anonymization, two musculoskeletal radiologists evaluated the 2D and 3D datasets independently. Descriptive statistics, inter-reader reliability, inter-method concordance, diagnostic definitiveness tests were applied. P-values < 0.05 were considered significant., Results: Raters diagnosed 116 cartilage defects with 2D and 109 with 3D MRI, 35 ligament tears with 2D and 65 with 3D MRI, 18 tendon tears with 2D and 20 with 3D MRI, and 137 osseous abnormalities with 2D and 149 with 3D MRI. The inter-reader agreement was high for 2D (Kendall W, 0.925) and 3D MRI (W, 0.936) (p < 0.05), as was the inter-method concordance (W, 0.919). The diagnostic definitiveness of readers was higher for 3D MRI than 2D MRI in 10-27% of the time, while the reverse was true in 7-11% of the time (p < 0.01)., Conclusions: The performance of 10-min 3D CAIPIRINHA SPACE MRI for the detection of painful ankle conditions is similar to that of a 20-min 2D TSE MRI reference standard., Key Points: • CAIPIRINHA Acceleration facilitates isotropic 3D MRI of the Ankle in 10 min. • 10-min 3D CAIPIRINHA MRI and 20-min 2D TSE MRI have similar performance. • 3D CAIPIRINHA SPACE MRI afforded higher diagnostic definitiveness of readers.
- Published
- 2019
- Full Text
- View/download PDF
38. Repeatability of Dixon magnetic resonance imaging and magnetic resonance spectroscopy for quantitative muscle fat assessments in the thigh.
- Author
-
Grimm A, Meyer H, Nickel MD, Nittka M, Raithel E, Chaudry O, Friedberger A, Uder M, Kemmler W, Engelke K, and Quick HH
- Subjects
- Adipose Tissue pathology, Adiposity, Adult, Aged, Aged, 80 and over, Body Composition, Case-Control Studies, Humans, Male, Muscle, Skeletal pathology, Organ Size, Reproducibility of Results, Sarcopenia diagnostic imaging, Sarcopenia pathology, Young Adult, Adipose Tissue diagnostic imaging, Magnetic Resonance Imaging, Magnetic Resonance Spectroscopy, Muscle, Skeletal diagnostic imaging, Thigh diagnostic imaging
- Abstract
Background: Changes in muscle fat composition as for example observed in sarcopenia or muscular dystrophy affect physical performance and muscular function, like strength and power. The purpose of the present study is to measure the repeatability of Dixon magnetic resonance imaging (MRI) for assessing muscle volume and fat in the thigh. Furthermore, repeatability of magnetic resonance spectroscopy (MRS) for assessing muscle fat is determined., Methods: A prototype 6-point Dixon MRI method was used to measure muscle volume and muscle proton density fat fraction (PDFF) in the left thigh. PDFF was measured in musculus semitendinosus of the left thigh with a T2-corrected multi-echo MRS method. For the determination of short-term repeatability (consecutive examinations), the root mean square coefficients of variation of Dixon MRI and MRS data of 23 young and healthy (29 ± 5 years) and 24 elderly men with sarcopenia (78 ± 5 years) were calculated. For the estimation of the long-term repeatability (13 weeks between examinations), the root mean square coefficients of variation of MRI data of seven young and healthy (31 ± 7 years) and 23 elderly sarcopenic men (76 ± 5 years) were calculated. Long-term repeatability of MRS was not determined., Results: Short-term errors of Dixon MRI volume measurement were between 1.2% and 1.5%, between 2.1% and 1.6% for Dixon MRI PDFF measurement, and between 9.0% and 15.3% for MRS. Because of the high short-term repeatability errors of MRS, long-term errors were not determined. Long-term errors of MRI volume measurement were between 1.9% and 4.0% and of Dixon MRI PDFF measurement between 2.1% and 4.2%., Conclusions: The high degree of repeatability of volume and PDFF Dixon MRI supports its use to predict future mobility impairment and measures the success of therapeutic interventions, for example, in sarcopenia in aging populations and muscular dystrophy. Because of possible inhomogeneity of fat infiltration in muscle tissue, the application of MRS for PDFF measurements in muscle is more problematic because this may result in high repeatability errors. In addition, the tissue composition within the MRS voxel may not be representative for the whole muscle., (© 2018 The Authors. Journal of Cachexia, Sarcopenia and Muscle published by John Wiley & Sons Ltd on behalf of the Society on Sarcopenia, Cachexia and Wasting Disorders.)
- Published
- 2018
- Full Text
- View/download PDF
39. Accelerated Internal Auditory Canal Screening Magnetic Resonance Imaging Protocol With Compressed Sensing 3-Dimensional T2-Weighted Sequence.
- Author
-
Yuhasz M, Hoch MJ, Hagiwara M, Bruno MT, Babb JS, Raithel E, Forman C, Anwar A, Thomas Roland J Jr, and Shepherd TM
- Subjects
- Ear, Inner diagnostic imaging, Female, Humans, Male, Middle Aged, Reproducibility of Results, Retrospective Studies, Image Interpretation, Computer-Assisted methods, Imaging, Three-Dimensional methods, Labyrinth Diseases diagnostic imaging, Magnetic Resonance Imaging methods
- Abstract
Background and Purpose: High-resolution T2-weighted sequences are frequently used in magnetic resonance imaging (MRI) studies to assess the cerebellopontine angle and internal auditory canal (IAC) in sensorineural hearing loss patients but have low yield and lengthened examinations. Because image content in the Wavelet domain is sparse, compressed sensing (CS) that uses incoherent undersampling of k-space and iterative reconstruction can accelerate MRI acquisitions. We hypothesized that an accelerated CS T2 Sampling Perfection with Application optimized Contrasts using different flip angle Evolution (SPACE) sequence would produce acceptable diagnostic quality for IAC screening protocols., Material and Methods: Seventy-six patients underwent 3 T MRI using conventional SPACE and a CS T2 SPACE prototype sequence for screening the IACs were identified retrospectively. Unilateral reconstructions for each sequence were separated, then placed into mixed folders for independent, blinded review by 3 neuroradiologists during 2 sessions 4 weeks apart. Radiologists reported if a lesion was present. Motion and visualization of specific structures were rated using ordinal scales. McNemar, Wilcoxon, Cohen κ, and Mann-Whitney U tests were performed for accuracy, equivalence, and interrater and intrarater reliability., Results: T2 SPACE using CS reconstruction reduced scan time by 80% to 50 seconds and provided 98.7% accuracy for IAC mass detection by 3 raters. Radiologists preferred conventional images (0.7-1.0 reduction on 5-point scale, P < 0.001), but rated CS SPACE acceptable. The 95% confidence for reduction in any cerebellopontine angle, IAC, or fluid-filled inner ear structure assessment with CS SPACE did not exceed 0.5., Conclusions: Internal auditory canal screening MRI protocols can be performed using a 5-fold accelerated T2 SPACE sequence with compressed sensing while preserving diagnostic image quality and acceptable lesion detection rate.
- Published
- 2018
- Full Text
- View/download PDF
40. Fully Automated 10-Minute 3D CAIPIRINHA SPACE TSE MRI of the Knee in Adults: A Multicenter, Multireader, Multifield-Strength Validation Study.
- Author
-
Del Grande F, Delcogliano M, Guglielmi R, Raithel E, Stern SE, Papp DF, Candrian C, and Fritz J
- Subjects
- Adolescent, Adult, Aged, Female, Humans, Male, Middle Aged, Observer Variation, Prospective Studies, Reproducibility of Results, Sensitivity and Specificity, Time, Young Adult, Imaging, Three-Dimensional methods, Joint Diseases diagnostic imaging, Knee Joint diagnostic imaging, Magnetic Resonance Imaging methods
- Abstract
Objectives: The aim of this study was to test the hypothesis that magnetic resonance imaging (MRI) of the knee with 10-minute 3-dimensional (3D) controlled aliasing in parallel imaging results in higher acceleration (CAIPIRINHA) sampling perfection with application optimized contrast using different flip angle evolutions (SPACE) turbo spin echo (TSE) protocols can replace 20-minute 2-dimensional (2D) TSE standard-of-reference protocols for the diagnosis of internal derangement., Materials and Methods: After internal review board approval and prospective informed consent, 100 symptomatic subjects underwent MRI of the knee at 3 T and 50 symptomatic subjects at 1.5 T, consisting of 10-minute 3D CAIPIRINHA SPACE TSE and 20-minute standard-of-reference 2D TSE protocols. Two fellowship-trained musculoskeletal radiologists assessed the studies in an anonymized and randomized fashion for structural abnormalities. Descriptive statistics, interreader reliability, intermethod concordance, diagnostic definitiveness, and interchangeability tests were applied. P values equal to or smaller than 0.01 were considered significant., Results: The interchangeability analysis showed that the 3D MRI can replace the 2D MRI protocols, whereas a superiority of 3D MRI was suggested statistically for the detection of medial and lateral meniscal tears, cartilage defects, and bone marrow edema by significantly higher common pair exact match proportions of readers (P < 0.01, respectively).The overall interreader reliabilities were 89% of exact matches for 2D TSE (κ, 0.842) and 96% of exact matches for 3D TSE (κ, 0.941) (P < 0.01). There was good intermethod concordance (κ, 0.736; range, 0.579-1.000). The interreader reliability (2D TSE: κ, 0.748 [0.603-1.000]; 3D TSE: κ, 0.901 [0.797-1.000]) and diagnostic definitiveness were significantly higher for the 3D than 2D MRI (P < 0.01)., Conclusions: 10-minute 3D CAIPIRINHA SPACE TSE MRI protocols can replace 20-minute 2D TSE standard-of-reference MRI protocols for the evaluation of internal derangement of the knee by producing similar results in individual patient diagnoses, whereas interpretations of 3D CAIPIRINHA SPACE TSE MRI examinations resulted in an overall higher interreader reliability, intermethod concordance, and reader definitiveness.
- Published
- 2018
- Full Text
- View/download PDF
41. Evaluation of 2-point, 3-point, and 6-point Dixon magnetic resonance imaging with flexible echo timing for muscle fat quantification.
- Author
-
Grimm A, Meyer H, Nickel MD, Nittka M, Raithel E, Chaudry O, Friedberger A, Uder M, Kemmler W, Quick HH, and Engelke K
- Subjects
- Adult, Aged, Female, Humans, Male, Middle Aged, Young Adult, Adipose Tissue diagnostic imaging, Image Processing, Computer-Assisted methods, Magnetic Resonance Imaging methods, Muscle, Skeletal diagnostic imaging
- Abstract
The purpose of this study is to evaluate and compare 2-point (2pt), 3-point (3pt), and 6-point (6pt) Dixon magnetic resonance imaging (MRI) sequences with flexible echo times (TE) to measure proton density fat fraction (PDFF) within muscles. Two subject groups were recruited (G1: 23 young and healthy men, 31 ± 6 years; G2: 50 elderly men, sarcopenic, 77 ± 5 years). A 3-T MRI system was used to perform Dixon imaging on the left thigh. PDFF was measured with six Dixon prototype sequences: 2pt, 3pt, and 6pt sequences once with optimal TEs (in- and opposed-phase echo times), lower resolution, and higher bandwidth (optTE sequences) and once with higher image resolution (highRes sequences) and shortest possible TE, respectively. Intra-fascia PDFF content was determined. To evaluate the comparability among the sequences, Bland-Altman analysis was performed. The highRes 6pt Dixon sequences served as reference as a high correlation of this sequence to magnetic resonance spectroscopy has been shown before. The PDFF difference between the highRes 6pt Dixon sequence and the optTE 6pt, both 3pt, and the optTE 2pt was low (between 2.2% and 4.4%), however, not to the highRes 2pt Dixon sequence (33%). For the optTE sequences, difference decreased with the number of echoes used. In conclusion, for Dixon sequences with more than two echoes, the fat fraction measurement was reliable with arbitrary echo times, while for 2pt Dixon sequences, it was reliable with dedicated in- and opposed-phase echo timing., (Copyright © 2018 Elsevier B.V. All rights reserved.)
- Published
- 2018
- Full Text
- View/download PDF
42. Accelerated whole brain intracranial vessel wall imaging using black blood fast spin echo with compressed sensing (CS-SPACE).
- Author
-
Zhu C, Tian B, Chen L, Eisenmenger L, Raithel E, Forman C, Ahn S, Laub G, Liu Q, Lu J, Liu J, Hess C, and Saloner D
- Subjects
- Adult, Aged, Algorithms, Cerebrovascular Disorders diagnostic imaging, Female, Healthy Volunteers, Humans, Image Processing, Computer-Assisted, Imaging, Three-Dimensional, Male, Middle Aged, Models, Statistical, Poisson Distribution, Reproducibility of Results, Signal-To-Noise Ratio, Aneurysm diagnostic imaging, Atherosclerosis diagnostic imaging, Brain blood supply, Brain diagnostic imaging, Cerebrovascular Circulation, Contrast Media chemistry, Magnetic Resonance Imaging
- Abstract
Objective: Develop and optimize an accelerated, high-resolution (0.5 mm isotropic) 3D black blood MRI technique to reduce scan time for whole-brain intracranial vessel wall imaging., Materials and Methods: A 3D accelerated T
1 -weighted fast-spin-echo prototype sequence using compressed sensing (CS-SPACE) was developed at 3T. Both the acquisition [echo train length (ETL), under-sampling factor] and reconstruction parameters (regularization parameter, number of iterations) were first optimized in 5 healthy volunteers. Ten patients with a variety of intracranial vascular disease presentations (aneurysm, atherosclerosis, dissection, vasculitis) were imaged with SPACE and optimized CS-SPACE, pre and post Gd contrast. Lumen/wall area, wall-to-lumen contrast ratio (CR), enhancement ratio (ER), sharpness, and qualitative scores (1-4) by two radiologists were recorded., Results: The optimized CS-SPACE protocol has ETL 60, 20% k-space under-sampling, 0.002 regularization factor with 20 iterations. In patient studies, CS-SPACE and conventional SPACE had comparable image scores both pre- (3.35 ± 0.85 vs. 3.54 ± 0.65, p = 0.13) and post-contrast (3.72 ± 0.58 vs. 3.53 ± 0.57, p = 0.15), but the CS-SPACE acquisition was 37% faster (6:48 vs. 10:50). CS-SPACE agreed with SPACE for lumen/wall area, ER measurements and sharpness, but marginally reduced the CR., Conclusion: In the evaluation of intracranial vascular disease, CS-SPACE provides a substantial reduction in scan time compared to conventional T1 -weighted SPACE while maintaining good image quality.- Published
- 2018
- Full Text
- View/download PDF
43. Metal artifact reduction MRI of total ankle arthroplasty implants.
- Author
-
de Cesar Netto C, Fonseca LF, Fritz B, Stern SE, Raithel E, Nittka M, Schon LC, and Fritz J
- Subjects
- Aged, Ankle Joint surgery, Female, Humans, Male, Middle Aged, Ankle Joint diagnostic imaging, Arthroplasty, Replacement, Ankle, Artifacts, Image Enhancement methods, Magnetic Resonance Imaging methods, Prostheses and Implants
- Abstract
Objectives: To assess high-bandwidth and compressed sensing-(CS)-SEMAC turbo spin echo (TSE) techniques for metal artifact reduction MRI of total ankle arthroplasty (TAA) implants., Methods: Following institutional approval and consent, 40 subjects with TAA implants underwent 1.5-T MRI prospectively. Evaluations included bone-implant interfaces, anatomical structures, abnormal findings and differential diagnoses before and after MRI. AUCs of P-P plots were used to determine superiority. Statistical differences were evaluated with McNemar and chi-square tests. P-values ≤ 0.05 were considered significant., Results: CS-SEMAC TSE was superior to high-bandwidth TSE in showing the bone-implant interfaces (AUC=0.917), periprosthetic bone, tendons and joint capsule (AUC=0.337-0.766), bone marrow oedema (43 % difference, p=0.041), interface osteolysis (63 %, p=0.015), tendinopathy (62 %, p=0.062), periprosthetic fractures (60 %, p=0.250), synovitis (43 %, p=0.250), as well as reader confidence for bone marrow oedema (p=<0.001), fracture (p=0.001), interface osteolysis (p=0.003), synovitis (p=0.027) and tendinopathy (p=0.034). The number of differential diagnoses in symptomatic subjects after the MRI with CS-SEMAC decreased from 3 (1-4) to 1 (1-2) (p<0.001)., Conclusions: MRI of TAA implants with CS-SEMAC improves the diagnosis of interface osteolysis, periprosthetic bone marrow oedema, fractures and tendinopathy when compared to high-BW TSE, and has a positive effect on patient management., Key Points: • High-bandwidth TSE and compressed sensing SEMAC improve MRI of ankle arthroplasty implants. • Compressed sensing SEMAC improves bone-implant interfaces, periprosthetic bone, tendons and joint capsule visibility. • Compressed sensing SEMAC improves the diagnosis of osteolysis, tendinopathy, fractures and synovitis. • MRI decreases the number of clinical differential diagnoses of painful ankle arthroplasty implants.
- Published
- 2018
- Full Text
- View/download PDF
44. Instrument visualization using conventional and compressed sensing SEMAC for interventional MRI at 3T.
- Author
-
Sonnow L, Gilson WD, Raithel E, Nittka M, Wacker F, and Fritz J
- Subjects
- Adult, Aged, Animals, Biopsy, Needle, Cadaver, Feasibility Studies, Female, Fourier Analysis, Humans, Image Enhancement methods, Image Interpretation, Computer-Assisted methods, Image Processing, Computer-Assisted, Male, Middle Aged, Phantoms, Imaging, Prospective Studies, Reproducibility of Results, Signal-To-Noise Ratio, Time Factors, Young Adult, Artifacts, Contrast Media chemistry, Magnetic Resonance Imaging, Interventional
- Abstract
Background: Interventional magnetic resonance imaging (MRI) at 3T benefits from higher spatial and temporal resolution, but artifacts of metallic instruments are often larger and may obscure target structures., Purpose: To test that compressed sensing (CS) slice-encoding metal artifact correction (SEMAC) is feasible for 3T interventional MRI and affords more accurate instrument visualization than turbo spin echo (TSE) and gradient echo (GRE) techniques, and facilitates faster data acquisition than conventional SEMAC., Study Type: Prospective., Phantom and Subjects: Cadaveric animal and 20 human subjects., Field Strength/sequence: TSE (acquisition time 31 sec), GRE (28-33 sec), SEMAC (128 sec), and CS-SEMAC (57 sec) pulse sequences were evaluated at 3T., Assessment: Artifact width and length, signal-to-noise (SNR), and contrast-to-noise (CNR) ratios of 14-22G MR-conditional needles were measured in a phantom. Subsequently, high-bandwidth TSE and CS-SEMAC sequences were assessed in vivo with 20 patient procedures for the size of the metal artifact, image sharpness, image noise, motion artifacts, image contrast, and target, instrument, and structural visibility., Statistical Tests: Repeated-measures-analysis-of-variances and Mann-Whitney U-tests were applied. P ≤ 0.05 was considered statistically significant., Results: CS-SEMAC and SEMAC created the smallest needle artifact widths (3.2-3.3 ± 0.4 mm, P = 1.0), whereas GRE showed the largest needle artifact widths (8.5-8.6 ± 0.4 mm) (P < 0.001). The artifact width difference between high-bandwidth TSE and CS-SEMAC was 0.8 ± 0.6 mm (P < 0.01). SEMAC and CS-SEMAC created the lowest average needle tip errors (0.3-0.4 ± 0.1 mm, P = 1.0). The average tip error difference between high-bandwidth TSE and SEMAC/CS-SEMAC was 2.0 ± 1.7 mm (P < 0.01). SNR and CNR were similar on TSE, SEMAC, and CS-SEMAC, and lowest on GRE. CS-SEMAC yielded smaller artifacts, less noise, less motion, and better instrument visibility (P < 0.001); high-bandwidth TSE showed better sharpness (P < 0.001) and targets visibility (P = 0.007); whereas image contrast (P = 0.273) and structural visibility (P = 0.1) were similar., Data Conclusion: CS-SEMAC is feasible for interventional MRI at 3T, visualizes instruments with higher accuracy than high-bandwidth TSE and GRE, and can be acquired 55% faster than conventional SEMAC., Level of Evidence: 2 Technical Efficacy: Stage 6 J. Magn. Reson. Imaging 2018;47:1306-1315., (© 2017 International Society for Magnetic Resonance in Medicine.)
- Published
- 2018
- Full Text
- View/download PDF
45. Compressed-Sensing Accelerated 3-Dimensional Magnetic Resonance Cholangiopancreatography: Application in Suspected Pancreatic Diseases.
- Author
-
Zhu L, Wu X, Sun Z, Jin Z, Weiland E, Raithel E, Qian T, and Xue H
- Subjects
- Adult, Aged, Aged, 80 and over, Artifacts, Breath Holding, Female, Humans, Male, Middle Aged, Pancreas diagnostic imaging, Prospective Studies, ROC Curve, Reproducibility of Results, Young Adult, Cholangiopancreatography, Magnetic Resonance methods, Imaging, Three-Dimensional methods, Pancreatic Diseases diagnostic imaging, Signal Processing, Computer-Assisted
- Abstract
Objectives: The aims of this study were to prospectively evaluate image quality, duct visibility, and diagnostic performance in duct-related pathologies of compressed-sensing (CS) accelerated 3-dimensional (3D) magnetic resonance cholangiopancreatography (MRCP) prototype protocols and compare these with those of conventional 3D MRCP protocol in patients with suspected pancreatic diseases., Material and Methods: The institutional review board approved this prospective study and all patients provided written informed consent. A total of 80 patients (47 men and 33 women; median age, 57 years; age range, 24-87 years) underwent 3D MRCP at 3.0 T. Three protocols were performed in each patient in random order: CS breath-hold (BH) protocol, CS navigator-triggered (NT) protocol, and conventional NT protocol. The acquisition time of each protocol was recorded. Image quality and duct visibility were independently rated in random order on a 5-point scale by 2 radiologists, who were blinded to the protocols. Receiver operating characteristic curves were generated, and area under the curve (Az value) was used to compare the diagnostic performance of each protocol in duct-related pathologies., Results: Acquisition time was 17 seconds for the CS-BH and 134.1 ± 33.5 seconds for the CS-NT protocol, both being significantly shorter than the conventional NT protocol (364.7 ± 78.4 seconds; both P < 0.01). The CS-BH MRCP protocol showed significantly less artifacts compared with the CS-NT and conventional NT protocols (both P < 0.01). Visualization of bile ducts was comparable in all 3 protocols, whereas CS-NT and conventional NT MRCP depicted pancreatic duct better than CS-BH MRCP did (for proximal, middle, and distal segment; all P < 0.05). Compressed-sensing-NT MRCP had the highest diagnostic performance for detecting ductal anomalies, long-segment duct stenosis, abnormal branch ducts, and communication between cystic lesion and pancreatic duct (mean Az value, 0.943-0.983)., Conclusions: Compressed-sensing MRCP is feasible in patients with suspected pancreatic diseases. Compressed-sensing-NT MRCP demonstrated superior diagnostic accuracy for duct-related pathologies.
- Published
- 2018
- Full Text
- View/download PDF
46. Clinical Feasibility of 3-Dimensional Magnetic Resonance Cholangiopancreatography Using Compressed Sensing: Comparison of Image Quality and Diagnostic Performance.
- Author
-
Yoon JH, Lee SM, Kang HJ, Weiland E, Raithel E, Son Y, Kiefer B, and Lee JM
- Subjects
- Adolescent, Adult, Aged, Aged, 80 and over, Feasibility Studies, Female, Humans, Male, Middle Aged, Reproducibility of Results, Retrospective Studies, Young Adult, Bile Duct Diseases diagnostic imaging, Cholangiopancreatography, Magnetic Resonance methods, Image Interpretation, Computer-Assisted methods, Imaging, Three-Dimensional methods, Pancreatic Diseases diagnostic imaging
- Abstract
Objective: The aim of this study was to evaluate the clinical feasibility of fast 3-dimensional (3D) magnetic resonance cholangiopancreatography (MRCP) using compressed sensing (CS) in comparison with conventional navigator-triggered 3D-MRCP., Materials and Methods: This retrospective study was approved by our institutional review board, and the requirement of informed consent was waived. A total of 84 patients (male-to-female ratio, 41:43; mean age, 47.3 ± 18.8 years) who underwent conventional 3D navigator-triggered T2-weighted MRCP using sampling perfection with application optimized contrasts (SPACE) and fast 3D MRCP using SPACE with high undersampling combined with CS reconstruction (CS SPACE; CS-MRCP) on a 3 T scanner were included. Among them, 28 patients additionally underwent 3D breath-hold CS-MRCP (BH-CS-MRCP) with 5.7% k-space sampling. Three board-certified radiologists then independently reviewed the examinations for bile duct and pancreatic duct visualization and overall image quality on a 5-point scale, and image sharpness and background suppression on a 4-point scale, with the higher score indicating better image quality. In addition, diagnostic performance for the detection of anatomic variation and diseases of the bile duct, and pancreatic disease were assessed on a per-patient basis in the subgroup of 28 patients who underwent conventional MRCP, CS-MRCP, and BH-CS-MRCP in the same manner., Results: Mean acquisition times of conventional MRCP, CS-MRCP, and BH-CS-MRCP were 7 minutes (419.7 seconds), 3 minutes 47 seconds (227.0 seconds), and 16 seconds, respectively (P < 0.0001, in all comparisons). In all patients, CS-MRCP showed better image sharpness (3.54 ± 0.60 vs 3.37 ± 0.75, P = 0.04) and visualization of the common bile duct (4.55 ± 0.60 vs 4.39 ± 0.78, P = 0.034) and pancreatic duct (3.47 ± 1.22 vs 3.26 ± 1.32, P = 0.025), but lower background suppression (3.00 ± 0.54 vs 3.37 ± 0.58, P < 0.001) than conventional MRCP. Overall image quality was not significantly different between the 2 examinations (3.51 ± 0.95 vs 3.47 ± 1.09, P = 0.75). The number of indeterminate MRCP examinations for the anatomic variation and disease of the bile duct significantly decreased on CS-MRCP, from 16.7%-22.6% to 9.5%-11.9% and 8.4%-15.6% to 3.6%-8.4% in all readers (P = 0.003-0.03). In the 28 patients who underwent BH-CS-MRCP, better image quality was demonstrated than with conventional MRCP and CS-MRCP (4.10 ± 0.84 vs 3.44 ± 1.21 vs 3.50 ± 1.11, respectively, P = 0.002, 0.001). Sensitivities for detecting bile duct disease was 88.9% to 100% on both BH-CS-MRCP and conventional MRCP (P > 0.05), and for detecting pancreatic disease was 66.7% to 83.3% on BH-CS-MRCP and 50.0% to 72.2% on conventional MRCP (P = 0.002 in reader 1, 0.06-0.47 in readers 2-3)., Conclusions: Compressed sensing MRCP using incoherent undersampling combined with CS reconstruction provided comparable image quality to conventional MRCP while reducing the acquisition time to within a single breath-hold (16 seconds).
- Published
- 2017
- Full Text
- View/download PDF
47. CAIPIRINHA accelerated SPACE enables 10-min isotropic 3D TSE MRI of the ankle for optimized visualization of curved and oblique ligaments and tendons.
- Author
-
Kalia V, Fritz B, Johnson R, Gilson WD, Raithel E, and Fritz J
- Subjects
- Adult, Artifacts, Female, Humans, Imaging, Three-Dimensional methods, Male, Middle Aged, Prospective Studies, Reproducibility of Results, Sensitivity and Specificity, Young Adult, Ankle Joint diagnostic imaging, Ligaments diagnostic imaging, Magnetic Resonance Imaging methods, Tendons diagnostic imaging
- Abstract
Objectives: To test the hypothesis that a fourfold CAIPIRINHA accelerated, 10-min, high-resolution, isotropic 3D TSE MRI prototype protocol of the ankle derives equal or better quality than a 20-min 2D TSE standard protocol., Methods: Following internal review board approval and informed consent, 3-Tesla MRI of the ankle was obtained in 24 asymptomatic subjects including 10-min 3D CAIPIRINHA SPACE TSE prototype and 20-min 2D TSE standard protocols. Outcome variables included image quality and visibility of anatomical structures using 5-point Likert scales. Non-parametric statistical testing was used. P values ≤0.001 were considered significant., Results: Edge sharpness, contrast resolution, uniformity, noise, fat suppression and magic angle effects were without statistical difference on 2D and 3D TSE images (p > 0.035). Fluid was mildly brighter on intermediate-weighted 2D images (p < 0.001), whereas 3D images had substantially less partial volume, chemical shift and no pulsatile-flow artifacts (p < 0.001). Oblique and curved planar 3D images resulted in mildly-to-substantially improved visualization of joints, spring, bifurcate, syndesmotic, collateral and sinus tarsi ligaments, and tendons (p < 0.001, respectively)., Conclusions: 3D TSE MRI with CAIPIRINHA acceleration enables high-spatial resolution oblique and curved planar MRI of the ankle and visualization of ligaments, tendons and joints equally well or better than a more time-consuming anisotropic 2D TSE MRI., Key Points: • High-resolution 3D TSE MRI improves visualization of ankle structures. • Limitations of current 3D TSE MRI include long scan times. • 3D CAIPIRINHA SPACE allows now a fourfold-accelerated data acquisition. • 3D CAIPIRINHA SPACE enables high-spatial-resolution ankle MRI within 10 min. • 10-min 3D CAIPIRINHA SPACE produces equal-or-better quality than 20-min 2D TSE.
- Published
- 2017
- Full Text
- View/download PDF
48. Sparse-SEMAC: rapid and improved SEMAC metal implant imaging using SPARSE-SENSE acceleration.
- Author
-
Otazo R, Nittka M, Bruno M, Raithel E, Geppert C, Gyftopoulos S, Recht M, and Rybak L
- Subjects
- Cadaver, Data Compression methods, Humans, Image Interpretation, Computer-Assisted methods, Observer Variation, Reproducibility of Results, Sensitivity and Specificity, Algorithms, Artifacts, Image Enhancement methods, Magnetic Resonance Imaging methods, Metals, Prostheses and Implants, Signal Processing, Computer-Assisted
- Abstract
Purpose: To develop an accelerated SEMAC metal implant MRI technique (Sparse-SEMAC) with reduced scan time and improved metal distortion correction., Methods: Sparse-SEMAC jointly exploits the inherent sparsity along the additional phase-encoding dimension and multicoil encoding capabilities to significantly accelerate data acquisition. A prototype pulse sequence with pseudorandom k
y -kz undersampling and an inline image reconstruction was developed for integration in clinical studies. Three patients with hip implants were imaged using the proposed Sparse-SEMAC with eight-fold acceleration and compared with the standard-SEMAC technique used in clinical studies (three-fold GRAPPA acceleration). Measurements were performed with SEMAC-encoding steps (SES) = 15 for Sparse-SEMAC and SES = 9 for Standard-SEMAC using high spatial resolution Proton Density (PD) and lower-resolution STIR acquisitions. Two expert musculoskeletal (MSK) radiologists performed a consensus reading to score image-quality parameters., Results: Sparse-SEMAC enables up to eight-fold acceleration of data acquisition that results in two-fold scan time reductions, compared with Standard-SEMAC, with improved metal artifact correction for patients with hip implants without degrading spatial resolution., Conclusion: The high acceleration enabled by Sparse-SEMAC would enable clinically feasible examination times with improved correction of metal distortion. Magn Reson Med 78:79-87, 2017. © 2016 International Society for Magnetic Resonance in Medicine., (© 2016 International Society for Magnetic Resonance in Medicine.)- Published
- 2017
- Full Text
- View/download PDF
49. Comparing an accelerated 3D fast spin-echo sequence (CS-SPACE) for knee 3-T magnetic resonance imaging with traditional 3D fast spin-echo (SPACE) and routine 2D sequences.
- Author
-
Altahawi FF, Blount KJ, Morley NP, Raithel E, and Omar IM
- Subjects
- Adolescent, Adult, Aged, Aged, 80 and over, Female, Humans, Male, Middle Aged, Prospective Studies, Image Enhancement methods, Image Processing, Computer-Assisted methods, Imaging, Three-Dimensional, Knee Joint diagnostic imaging, Magnetic Resonance Imaging methods
- Abstract
Purpose: To compare a faster, new, high-resolution accelerated 3D-fast-spin-echo (3D-FSE) acquisition sequence (CS-SPACE) to traditional 2D and high-resolution 3D sequences for knee 3-T magnetic resonance imaging (MRI)., Materials and Methods: Twenty patients received knee MRIs that included routine 2D (T1, PD ± FS, T2-FS; 0.5 × 0.5 × 3 mm
3 ; ∼10 min), traditional 3D FSE (SPACE-PD-FS; 0.5 × 0.5 × 0.5 mm3 ; ∼7.5 min), and accelerated 3D-FSE prototype (CS-SPACE-PD-FS; 0.5 × 0.5 × 0.5 mm3 ; ∼5 min) acquisitions on a 3-T MRI system (Siemens MAGNETOM Skyra). Three musculoskeletal radiologists (MSKRs) prospectively and independently reviewed the studies with graded surveys comparing image and diagnostic quality. Tissue-specific signal-to-noise ratios (SNR) and contrast-to-noise ratios (CNR) were also compared., Results: MSKR-perceived diagnostic quality of cartilage was significantly higher for CS-SPACE than for SPACE and 2D sequences (p < 0.001). Assessment of diagnostic quality of menisci and synovial fluid was higher for CS-SPACE than for SPACE (p < 0.001). CS-SPACE was not significantly different from SPACE but had lower assessments than 2D sequences for evaluation of bones, ligaments, muscles, and fat (p ≤ 0.004). 3D sequences had higher spatial resolution, but lower overall assessed contrast (p < 0.001). Overall image quality from CS-SPACE was assessed as higher than SPACE (p = 0.007), but lower than 2D sequences (p < 0.001). Compared to SPACE, CS-SPACE had higher fluid SNR and CNR against all other tissues (all p < 0.001)., Conclusions: The CS-SPACE prototype allows for faster isotropic acquisitions of knee MRIs over currently used protocols. High fluid-to-cartilage CNR and higher spatial resolution over routine 2D sequences may present a valuable role for CS-SPACE in the evaluation of cartilage and menisci.- Published
- 2017
- Full Text
- View/download PDF
50. Three-Dimensional CAIPIRINHA SPACE TSE for 5-Minute High-Resolution MRI of the Knee.
- Author
-
Fritz J, Fritz B, Thawait GG, Meyer H, Gilson WD, and Raithel E
- Subjects
- Adult, Aged, Artifacts, Female, Humans, Male, Middle Aged, Prospective Studies, Reproducibility of Results, Signal-To-Noise Ratio, Young Adult, Imaging, Three-Dimensional methods, Joint Diseases diagnostic imaging, Knee Joint diagnostic imaging, Magnetic Resonance Imaging methods
- Abstract
Objective: The aim of this study was to prospectively test the hypothesis that a 2-dimensional (2D) CAIPIRINHA (controlled aliasing in parallel imaging results in higher acceleration) sampling pattern facilitates 5-minute high spatial resolution 3-dimensional (3D) sampling perfection with application optimized contrast using different flip angle evolutions (SPACE) magnetic resonance imaging (MRI) of the knee with image quality similar or better than current 2D turbo spin echo (TSE) and 3D SPACE standards., Materials and Methods: The study was approved by our institutional review board. Twenty asymptomatic subjects (12 men, 8 women; mean age, 42 years; age range, 24-65 years) underwent 3 T MRI of the knee. A 4-fold accelerated 3D SPACE TSE prototype with 2D CAIPIRINHA sampling pattern and 5-minute acquisition time was compared with commercially available 2-fold and 4-fold accelerated 3D SPACE and 2D TSE pulse sequences with acquisition times of 11 minutes and 15 seconds, 6 minutes and 30 seconds, as well as 9 minutes and 48 seconds, respectively. Outcome variables included image quality, anatomic visibility, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR). Statistical analysis included Friedman, repeated measures analysis of variances, and Cohen's weighted κ tests. Bonferroni-corrected P values of 0.005 and less were considered statistically significant., Results: Overall, image quality, visibility of anatomic structures, SNR, and CNR of 3D CAIPIRINHA SPACE were statistically similar to 2-fold accelerated 3D SPACE and significantly better than 4-fold accelerated 3D SPACE, which exhibited degrading parallel imaging artifacts. Compared with 2.5-mm 2D TSE images, 0.5-mm 3D CAIPIRINHA SPACE images showed statistically similar good edge sharpness and very good contrast resolution, and significantly less partial volume as well as absent chemical shift and pulsatile flow artifacts. Visibility of menisci, anterior cruciate ligament, posterior cruciate ligament, medial collateral ligament, and lateral collateral ligament was good to very good on 0.5-mm 3D CAIPIRINHA SPACE images as compared with good on 2.5-mm 2D TSE image (P < 0.005). The SNR of fat, fluid, and cartilage as well as CNR between cartilage, fluid, fat, posterior cruciate ligament, and menisci were minimally higher on 2.5-mm 2D TSE image (P < 0.005). Image quality, visibility of anatomic structures, SNR, and CNR of 2.5-mm 3D CAIPIRINHA SPACE and 2.5-mm 2D TSE images were good to very good without significant differences., Conclusions: Three-dimensional SPACE with 2D CAIPIRINHA sampling pattern enables high-quality 3D TSE MRI of the knee at an acquisition time of 5 minutes and image quality, visibility of anatomic structures, SNR, and CNR similar to conventional 3D SPACE and 2D TSE, both of which require approximately 10-minute acquisition times.
- Published
- 2016
- Full Text
- View/download PDF