105 results on '"Reiner CS"'
Search Results
2. Präoperative Lebervolumetrie bei Leberteilresektionen: Evaluation der Konversionsfaktoren
- Author
-
Karlo, C, primary, Reiner, CS, additional, Breitenstein, S, additional, Weishaupt, D, additional, Marincek, B, additional, and Frauenfelder, T, additional
- Published
- 2009
- Full Text
- View/download PDF
3. La tomographie par résonance magnétique dans le diagnostic et le traitement de ladénocarcinome prostatique
- Author
-
Reiner, CS, primary and Weishaupt, D, additional
- Published
- 2008
- Full Text
- View/download PDF
4. Stellenwert der Magnetresonanztomographie in Diagnose und Therapie des Prostatakarzinoms
- Author
-
Reiner, CS, primary and Weishaupt, D, additional
- Published
- 2008
- Full Text
- View/download PDF
5. Beurteilung der Resektabilität von hilären Cholangiokarzinomen mittels Magnetresonanztomographie
- Author
-
Reiner, CS, primary, Breitenstein, S, additional, Clavien, PA, additional, Marincek, B, additional, and Weishaupt, D, additional
- Published
- 2008
- Full Text
- View/download PDF
6. Evaluation von Vakuum-unterstützten Biopsiesystemen für die MR-gezielte Brustbiopsie
- Author
-
Floery, D, primary, Duenkelmeyer, M, additional, Jaromi, S, additional, Fuchsjäger, M, additional, Riedl, CC, additional, Reiner, CS, additional, and Helbich, TH, additional
- Published
- 2006
- Full Text
- View/download PDF
7. Liver Perfusion Imaging in Patients with Primary and Metastatic Liver Malignancy: Prospective Comparison between (99m)Tc-MAA SPECT and Dynamic CT Perfusion.
- Author
-
Reiner CS, Goetti R, Burger IA, Fischer MA, Frauenfelder T, Knuth A, Pfammatter T, Schaefer N, and Alkadhi H
- Published
- 2012
8. Quantification of liver iron content with CT-added value of dual-energy.
- Author
-
Fischer MA, Reiner CS, Raptis D, Donati O, Goetti R, Clavien PA, Alkadhi H, Fischer, Michael A, Reiner, Caecilia S, Raptis, Dimitri, Donati, Olivio, Goetti, Robert, Clavien, Pierre-Alain, and Alkadhi, Hatem
- Subjects
- *
IRON metabolism , *LIVER radiography , *ADIPOSE tissues , *ALGORITHMS , *ANIMAL experimentation , *CATTLE , *COMPUTED tomography , *LIVER , *NONPARAMETRIC statistics , *IMAGING phantoms - Abstract
Objective: To evaluate the value of dual-energy CT (DECT) with use of an iron-specific, three-material decomposition algorithm for the quantification of liver iron content (LIC).Methods: Thirty-one phantoms containing liver tissue, fat and iron were scanned with dual-source CT using single-energy at 120 kV (SECT) and DECT at 80 kV and 140 kV. Virtual iron concentration (VIC) images derived from an iron-specific, three-material decomposition algorithm and measurements of fat-free and fat-containing phantoms were compared with the LIC and healthy liver tissue.Results: In the absence of fat significant linear correlations were found between LIC and HU from SECT and VIC (r = 0.984-0.997, p < 0.001) with a detection limit of 145.4 μmol/g LIC for SECT, whereas VIC accurately quantified the lowest LIC of 20 μmol/g dry liver. In the presence of fat, no significant correlation was observed between LIC and SECT, whereas significant correlations were found for VIC. Compared with fat-free phantoms, significant underestimation of LIC was seen for SECT with increasing amounts of fat (all, p ≤ 0.01). On the other hand, similar HU were seen for VIC of fat-containing compared with fat-free phantoms (p > 0.632).Conclusions: Virtual iron concentration images generated from DECT provide added value for the quantification of LIC by disregarding the confounding effect of the natural variation of healthy liver attenuation and of co-existing liver fat. [ABSTRACT FROM AUTHOR]- Published
- 2011
- Full Text
- View/download PDF
9. Molecular Imaging of Malignant Tumor Metabolism Whole-Body Image Fusion of DWI/CT vs. PET/CT.
- Author
-
Reiner CS, Fischer MA, Hany T, Stolzmann P, Nanz D, Donati OF, Weishaupt D, von Schulthess GK, and Scheffel H
- Published
- 2011
10. Diagnostic accuracy of whole-body MRI/DWI image fusion for detection of malignant tumours: a comparison with PET/CT.
- Author
-
Fischer MA, Nanz D, Hany T, Reiner CS, Stolzmann P, Donati OF, Breitenstein S, Schneider P, Weishaupt D, von Schulthess GK, Scheffel H, Fischer, Michael A, Nanz, Daniel, Hany, Thomas, Reiner, Caecilia S, Stolzmann, Paul, Donati, Olivio F, Breitenstein, Stefan, Schneider, Paul, and Weishaupt, Dominik
- Abstract
Objective: To prospectively evaluate the diagnostic accuracy of whole-body T2-weighted (wbT2), whole-body diffusion-weighted imaging (wbDWI) and wbT2/wbDWI image fusion for malignant tumour detection compared with PET/CT.Methods: Sixty-eight patients (44 men; 60 ± 14 years) underwent PET/CT for staging of malignancy and were consecutively examined by 1.5-Tesla MRI including wbT2 and wbDWI. Two radiologists independently assessed wbDWI, wbT2, wbT2 + wbDWI (side-by-side) and wbT2 + wbDWI + wbT2/wbDWI image fusion for the presence of malignancy. PET/CT served as a reference standard.Results: PET/CT revealed 374 malignant lesions in 48/64 (75%) patients. Detection rates and positive predictive value (PPV) of wbT2 and wbDWI alone were 64% and 84%, and 57% and 93%, respectively. Detection rates and PPV of wbT2 and wbDWI for side-by-side analysis without and with fused images were 72% and 89%, and 74% and 91%, respectively. The detection rate was significantly higher with side-by-side analysis and fused image analysis compared with wbT2 and wbDWI alone (p = .0159; p < .0001). There was no significant difference between fused image interpretation and side-by-side analysis.Conclusions: WbDWI allows detection of malignant lesions with a similar detection rate to wbT2. Side-by-side analysis of wbT2 and wbDWI significantly improves the overall detection rate and fused image data provides no added value. [ABSTRACT FROM AUTHOR]- Published
- 2011
- Full Text
- View/download PDF
11. Can galactography-guided stereotactic, 11-gauge, vacuum-assisted breast biopsy of intraductal lesions serve as an alternative to surgical biopsy?
- Author
-
Reiner CS, Helbich TH, Rudas M, Ponhold L, Riedl CC, Kropf N, Fuchsjäger MH, Reiner, Caecilia S, Helbich, Thomas H, Rudas, Margaretha, Ponhold, Lothar, Riedl, Christopher C, Kropf, Nina, and Fuchsjäger, Michael H
- Abstract
The purpose of this study was to determine the value of galactography-guided, stereotactic, vacuum-assisted breast biopsy (VABB) for the assessment of intraductal breast lesions and its potential as a therapeutic tool that could eliminate the need for surgical excision. Eighteen patients (median age 64 years, range 37-80) with nipple discharge and galactography-verified intraductal lesions underwent galactography-guided, stereotactic, 11-gauge VABB followed by surgery. Histopathology findings from VABB and subsequent surgery were compared. Underestimation and false-negative rates were assessed. After VABB, histopathology revealed invasive ductal carcinoma (IDC) in three (17%), ductal carcinoma in situ (DCIS) in six (33%), high-risk lesions in six (33%) and benign lesions in three (17%) cases. After surgical biopsy, histopathology confirmed the previously established diagnosis in 11 lesions (61%). The underestimation rate for high-risk lesions and DCIS was 50% (6/12). The false-negative rate was 7% (1/14). Histopathology examination after surgery showed that not a single lesion had been completely removed at VABB. Galactography-guided VABB is a feasible diagnostic tool. However, its value as a therapeutic procedure is limited because of the high number of underestimated and missed lesions and because of the histopathological detection of lesions' remnants in every case. Surgical excision should be the therapeutic gold standard in cases of pathological nipple discharge and galactography abnormalities. [ABSTRACT FROM AUTHOR]
- Published
- 2009
- Full Text
- View/download PDF
12. USPIO-enhanced magnetic resonance imaging of the knee in asymptomatic volunteers.
- Author
-
Reiner CS, Lutz AM, Tschirch F, Froehlich JM, Gaillard S, Marincek B, Weishaupt D, Reiner, C S, Lutz, A M, Tschirch, F, Froehlich, J M, Gaillard, S, Marincek, B, and Weishaupt, D
- Abstract
The aim of this study was to compare signal characteristics of the synovium in knees of asymptomatic volunteers before and after intravenous administration of ultrasmall superparamagnetic iron oxide particles (USPIO). Ten knees of 10 asymptomatic volunteers were examined before and 36 h after intravenous administration of USPIO on a 1.5-T MR system using T1-weighted spin-echo, T2-weighted fast spin-echo, T2*-weighted gradient-echo (GRE), and short inversion time inversion-recovery sequences. In addition, synovial perfusion was measured using Gd-enhanced GRE imaging during the first imaging session. Images were analyzed qualitatively for any visual changes before and after USPIO administration. Signal-to-noise ratios (SNR) of the synovium were determined on unenhanced and USPIO-enhanced sequences. All MR images were reviewed for presence of any degenerative changes. Qualitative image analysis revealed no visually detectable changes of any knee joint before and after USPIO administration. The SNR values of the synovium on T1w, T2w, and T2*w images before and after USPIO administration showed no significant difference (T1, P = 0.86; T2, P = 0.95; T2*, P = 0.86). None of the volunteers showed any relevant degenerative changes of the knee and synovial perfusion was within normal limits. In knees of asymptomatic volunteers without any relevant degenerative changes and normal synovial perfusion neither visual changes nor changes of SNR values of the synovium can be depicted after USPIO administration. This means that USPIO-enhanced MRI may be used for assessment of knee disorders with increased macrophage activity. [ABSTRACT FROM AUTHOR]
- Published
- 2009
- Full Text
- View/download PDF
13. Feasibility and performance of spin-echo EPI MR elastography at 3 Tesla for staging hepatic fibrosis in the presence of hepatic iron overload.
- Author
-
Sgier D, Stocker D, Jüngst C, Renzulli M, Biletska-Hanchorova H, Weber A, Kannengiesser S, Gubler C, and Reiner CS
- Subjects
- Humans, Male, Female, Middle Aged, Retrospective Studies, Adult, Aged, Echo-Planar Imaging methods, Liver diagnostic imaging, Liver pathology, Magnetic Resonance Imaging methods, Elasticity Imaging Techniques methods, Liver Cirrhosis diagnostic imaging, Feasibility Studies, Iron Overload diagnostic imaging
- Abstract
Purpose: To assess the feasibility and performance of MR elastography (MRE) for quantifying liver fibrosis in patients with and without hepatic iron overload., Methods: This retrospective single-center study analyzed 139 patients who underwent liver MRI at 3 Tesla including MRE (2D spin-echo EPI sequence) and R2* mapping for liver iron content (LIC) estimation. MRE feasibility and diagnostic performance between patients with normal and elevated LIC were compared., Results: Patients with elevated LIC (21%) had significantly higher MRE failure rates (24.1% vs. 3.6%, p < 0.001) compared to patients with normal LIC (79%). For those with only insignificant to mild iron overload (LIC < 5.4 mg/g; 17%), MRE failure rate did not differ significantly from patients without iron overload (8.3% vs. 3.6%, p = 0.315). R2* predicted MRE failure with fair accuracy at a threshold of R2* ≥ 269 s
-1 (LIC of approximately 4.6 mg/g). MRE showed good diagnostic performance for detecting significant (≥ F2) and severe fibrosis (≥ F3) in patients without (AUC 0.835 and 0.900) and with iron overload (AUC 0.818 and 0.889) without significant difference between the cohorts (p = 0.884 and p = 0.913). For detecting cirrhosis MRE showed an excellent diagnostic performance in both groups (AUC 0.944 and 1.000, p = 0.009)., Conclusion: Spin-echo EPI MRE at 3 Tesla is feasible in patients with mild iron overload with good to excellent performance for detecting hepatic fibrosis with a failure rate comparable to patients without iron overload., (© 2024. The Author(s).)- Published
- 2024
- Full Text
- View/download PDF
14. Assessment of pelvic organ prolapse with the Pelvic Inclination Correction System: defining the normal range and threshold to pathology.
- Author
-
Ghafoor S, Beintner-Skawran S, Betschart C, Winklehner T, and Reiner CS
- Subjects
- Humans, Female, Prospective Studies, Adult, Middle Aged, Reference Values, Aged, Pelvic Organ Prolapse diagnostic imaging, Magnetic Resonance Imaging methods
- Abstract
Purpose: To define the normal range and threshold values for pathologic prolapse on MRI using the PICS line and assess its correlation with the pubococcygeal line (PCL)., Methods: This prospective, IRB-approved study included 20 nulliparous volunteers and 18 prolapse patients (POP-Q Stage ≥ 2). Organ positions (bladder, cervix, anorectal junction) relative to PICS and PCL were measured on dynamic MRI. Differences in organ position were compared. Receiver-operating characteristic (ROC) analysis was performed to identify cutoff values for prolapse using the PICS line. The correlation between PICS and PCL measurements was tested with Spearman's rank correlation., Results: In volunteers, median bladder and cervix positions measured to the PICS at rest were - 2.7 cm and - 5.3 cm compared to - 1.9 cm and - 2.7 cm in patients (p < 0.001). During straining, bladder and cervix were at - 0.9 cm and - 3.2 cm in volunteers versus + 2.5 cm and + 2.5 cm in patients (p < 0.001). Correlation was strong for PICS and PCL measurements for all three compartments (δ = 0.883-0.970, p ≤ 0.001). AUCs of PICS for the anterior and middle compartment were 0.98 (95% confidence interval [CI] 0.96-1.00, p < 0.001) and 0.96 (95% CI 0.89-1.00, p < 0.001) for differentiating patients from healthy volunteers. AUC for the posterior compartment was 0.76 (95% CI 0.57-0.96, p = 0.034)., Conclusion: PICS measurements reliably differentiate patients from volunteers in the anterior and middle compartment. Future studies need to identify a reliable threshold for the posterior compartment. PICS and PCL measurements are strongly correlated., (© 2024. The Author(s).)
- Published
- 2024
- Full Text
- View/download PDF
15. Quantitative 3D Analysis of Levator Ani Muscle Subdivisions in Nulliparous Women: MRI Feasibility Study.
- Author
-
Moser N, Skawran S, Steigmiller K, Röhrnbauer B, Winklehner T, Reiner CS, and Betschart C
- Abstract
Background: The levator ani muscle (LAM) is crucial for pelvic floor stability, yet its quantitative MRI assessment is only a recent focus. Our study aims to standardize the quantitative analysis of the LAM morphology within the 3D Pelvic Inclination Correction System (3D-PICS)., Methods: We analyzed 35 static MR datasets from nulliparous women examining the pubovisceral (PVM), iliococcygeal (ICM), coccygeal (COC), and puborectal muscle (PRM). The PVM consists of three origin-insertion pairs, namely the puboanal (PAM), puboperineal (PPM) and pubovaginal muscle (PVaM). The analysis included a quantitative examination of the morphology of LAM, focusing on the median location (x/y/z) (x: anterior-posterior, y: superior-inferior, z: left-right) of the origin and insertion points (a), angles (b) and lengths (c) of LAM. Inter-rater reliability was calculated., Results: Interindividual variations in 3D coordinates among muscle subdivisions were shown. In all, 93% of all origin and insertion points were found within an SD of <8 mm. Angles to the xz-plane range between -15.4° (right PRM) and 40.7° (left PAM). The PRM is the largest pelvic muscle in static MRI. The ICC indicated moderate-to-good agreement between raters., Conclusions: The accurate morphometry of the LAM and its subdivisions, along with reliable inter-rater agreement, was demonstrated, enhancing the understanding of normal pelvic anatomy in young nulliparous women.
- Published
- 2024
- Full Text
- View/download PDF
16. MRI characterization of pelvic floor ligaments in nulliparous women: Technique development and morphometry within the 3D pelvic inclination correction system (3D-PICS).
- Author
-
Matter L, Hebeisen M, Beintner-Skawran S, Reiner CS, and Betschart C
- Subjects
- Humans, Female, Reproducibility of Results, Ligaments, Articular, Magnetic Resonance Imaging methods, Research Design, Pelvic Floor diagnostic imaging, Ligaments diagnostic imaging
- Abstract
Purpose: The aim of the MRI-study was to evaluate the visibility of the pelvic floor ligaments and to analyze the ligament morphometry in 3D space., Methods: Twenty-two nulliparous women underwent MRI with a ligament specific protocol. MR datasets were evaluated using the 3D Pelvic Inclination Correction System (3D-PICS). The round ligament (RL), sacrospinous ligament (SSL), sacrotuberous ligament (STL), urogenital diaphragm (UGD) and uterosacral ligament (USL) were analyzed. Qualitative and quantitative analysis was performed. 3D coordinates for origin and insertion points were determined relative to the symphysis; subsequently lengths and angles were calculated. Interrater reliability was calculated to validate the point determination method., Results: Moderate to good visibility was reported for the RL, the SSL, the STL and the UGD. Standard deviation of the points analyzed in the different dimensions vary from 1.5 mm to 21.3 mm. Origin and insertion points of the ligaments are found within a mean standard distance of 10.7 mm. The highest variability was seen in insertion points of RL, with a standard distance of 25.4 mm. The interrater reliability was good to very good (range of intraclass correlation coefficients (ICC) from 0.58 to 0.96), except for the UGD ventral points (ICC from 0.27 to 0.55)., Conclusions: This in-vivo MRI technique development study offers first exact data describing the pelvic floor ligaments in nulliparous women in 3D-PICS. Visibility, exact 3D coordinates of the origin and insertion points, lengths, angles and interrater reliability assessed for all parameters were evaluated morphometrically., Competing Interests: Declaration of competing interest The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper., (Copyright © 2024 The Authors. Published by Elsevier B.V. All rights reserved.)
- Published
- 2024
- Full Text
- View/download PDF
17. Individual Participant Data Meta-Analysis of LR-5 in LI-RADS Version 2018 versus Revised LI-RADS for Hepatocellular Carcinoma Diagnosis.
- Author
-
Goins SM, Jiang H, van der Pol CB, Salameh JP, Lam E, Adamo RG, McInnes MDF, Costa AF, Tang A, Alhasan AS, Allen BC, Reiner CS, Clarke C, Cerny M, Wang J, Choi SH, Fraum TJ, Ludwig DR, Song B, Joo I, Kang Z, Kierans AS, Kim SY, Kwon H, Ronot M, Podgórska J, Rosiak G, Song JS, and Bashir MR
- Subjects
- Humans, Retrospective Studies, Magnetic Resonance Imaging methods, Contrast Media, Sensitivity and Specificity, Multicenter Studies as Topic, Carcinoma, Hepatocellular pathology, Liver Neoplasms pathology
- Abstract
Background A simplification of the Liver Imaging Reporting and Data System (LI-RADS) version 2018 (v2018), revised LI-RADS (rLI-RADS), has been proposed for imaging-based diagnosis of hepatocellular carcinoma (HCC). Single-site data suggest that rLI-RADS category 5 (rLR-5) improves sensitivity while maintaining positive predictive value (PPV) of the LI-RADS v2018 category 5 (LR-5), which indicates definite HCC. Purpose To compare the diagnostic performance of LI-RADS v2018 and rLI-RADS in a multicenter data set of patients at risk for HCC by performing an individual patient data meta-analysis. Materials and Methods Multiple databases were searched for studies published from January 2014 to January 2022 that evaluated the diagnostic performance of any version of LI-RADS at CT or MRI for diagnosing HCC. An individual patient data meta-analysis method was applied to observations from the identified studies. Quality Assessment of Diagnostic Accuracy Studies version 2 was applied to determine study risk of bias. Observations were categorized according to major features and either LI-RADS v2018 or rLI-RADS assignments. Diagnostic accuracies of category 5 for each system were calculated using generalized linear mixed models and compared using the likelihood ratio test for sensitivity and the Wald test for PPV. Results Twenty-four studies, including 3840 patients and 4727 observations, were analyzed. The median observation size was 19 mm (IQR, 11-30 mm). rLR-5 showed higher sensitivity compared with LR-5 (70.6% [95% CI: 60.7, 78.9] vs 61.3% [95% CI: 45.9, 74.7]; P < .001), with similar PPV (90.7% vs 92.3%; P = .55). In studies with low risk of bias ( n = 4; 1031 observations), rLR-5 also achieved a higher sensitivity than LR-5 (72.3% [95% CI: 63.9, 80.1] vs 66.9% [95% CI: 58.2, 74.5]; P = .02), with similar PPV (83.1% vs 88.7%; P = .47). Conclusion rLR-5 achieved a higher sensitivity for identifying HCC than LR-5 while maintaining a comparable PPV at 90% or more, matching the results presented in the original rLI-RADS study. © RSNA, 2023 Supplemental material is available for this article . See also the editorial by Sirlin and Chernyak in this issue.
- Published
- 2023
- Full Text
- View/download PDF
18. Early Postoperative Serum Phosphate Drop Predicts Sufficient Hypertrophy After Liver Surgery.
- Author
-
Kambakamba P, Schneider MA, Linecker M, Kirimker EO, Moeckli B, Graf R, Reiner CS, Nguyen-Kim TDL, Kologlu M, Karayalcin K, Clavien PA, Balci D, and Petrowsky H
- Subjects
- Humans, Mice, Animals, Liver surgery, Hepatectomy adverse effects, Liver Regeneration, Portal Vein surgery, Hypertrophy surgery, Hepatomegaly, Phosphates, Ligation, Treatment Outcome, Liver Neoplasms surgery, Hypophosphatemia surgery
- Abstract
Objective: The aim of this study was to assess the impact of postoperative hypophosphatemia on liver regeneration after major liver surgery in the scenario of Associating Liver Partition with Portal vein ligation for Staged hepatectomy (ALPPS) and living liver donation (LLD)., Background: Hypophosphatemia has been described to reflect the metabolic demands of regenerating hepatocytes. Both ALPPS and LLD are characterized by an exceptionally strong liver regeneration and may be of particular interest in the context of posthepatectomy hypophosphatemia., Methods: Serum phosphate changes within the first 7 postoperative days after ALPPS (n=61) and LLD (n=54) were prospectively assessed and correlated with standardized volumetry after 1 week. In a translational approach, postoperative phosphate changes were investigated in mice and in vitro ., Results: After ALPPS stage 1 and LLD, serum phosphate levels significantly dropped from a preoperative median of 1.08 mmol/L [interquartile range (IQR) 0.92-1.23] and 1.07 mmol/L (IQR 0.91-1.21) to a postoperative median nadir of 0.68 and 0.52 mmol/L, respectively. A pronounced phosphate drop correlated well with increased liver hypertrophy ( P <0.001). Patients with a low drop of phosphate showed a higher incidence of posthepatectomy liver failure after ALPPS (7% vs 31%, P =0.041). Like in humans, phosphate drop correlated significantly with degree of hypertrophy in murine ALPPS and hepatectomy models ( P <0.001). Blocking phosphate transporter (Slc20a1) inhibited cellular phosphate uptake and hepatocyte proliferation in vitro., Conclusion: Phosphate drop after hepatectomy is a direct surrogate marker for liver hypertrophy. Perioperative implementation of serum phosphate analysis has the potential to detect patients with insufficient regenerative capacity at an early stage., Competing Interests: The authors report no conflicts of interest., (Copyright © 2023 Wolters Kluwer Health, Inc. All rights reserved.)
- Published
- 2023
- Full Text
- View/download PDF
19. Management of biliary obstruction in patients with newly diagnosed alveolar echinococcosis: a Swiss retrospective cohort study.
- Author
-
Müller S, Ghafoor S, Meyer Zu Schwabedissen C, Grimm F, Murray FR, Husmann L, Stanek N, Deplazes P, Schlag C, Kremer AE, Gubler C, Reiner CS, Semela D, Müllhaupt B, and Deibel A
- Subjects
- Humans, Retrospective Studies, Switzerland, Treatment Outcome, Bilirubin, Benzimidazoles, Cholestasis etiology, Cholestasis therapy
- Abstract
Background and Study Aims: Alveolar echinococcosis, an orphan zoonosis affecting the liver, is of increasing concern worldwide. Most symptomatic cases present at an advanced and inoperable stage, sometimes with biliary obstruction prompting biliary tract interventions. These are, however, associated with a high risk of infectious complications. The aim of this retrospective study was to compare the effectiveness and safety of conservative and interventional treatment approaches in patients with newly diagnosed alveolar echinococcosis and biliary obstruction., Patients and Methods: Alveolar echinococcosis patients treated at two referral centres in Switzerland, presenting with hyperbilirubinaemia (total bilirubin >1.5 Upper Limit of Normal) at diagnosis were included, unless another underlying aetiology, i.e. common bile duct stones or decompensated cirrhosis, was identified. Patients were divided into two groups, according to whether they initially received a biliary tract intervention. The primary endpoint was normalisation of bilirubin levels within a 6-month period. Secondary endpoints included, among others, the occurrence of early and late biliary complications, the need for biliary tract interventions during follow-up and overall duration of hospital stays for treatment initiation and for biliary complications., Results: 28 patients were included in this study, of whom 17 received benzimidazole therapy alone and 11 additionally received a biliary tract intervention. Baseline characteristics did not differ between groups. All but one patient in each group achieved the primary endpoint (p=0.747). Biliary tract intervention was associated with faster laboratory improvement (t1/2 1.3 vs 3.0 weeks), but also with more frequent early biliary complications (7/11 vs 1/17, p=0.002) and longer initial hospital stay (18 days vs 7 days, p=0.007)., Conclusion: Biliary obstruction in patients with newly diagnosed alveolar echinococcosis can be treated effectively with benzimidazole therapy alone. Biliary tract intervention, on the other hand, is associated with a high complication rate and should probably be reserved for patients with insufficient response to benzimidazole therapy.
- Published
- 2023
- Full Text
- View/download PDF
20. Pelvic organ movements in asymptomatic nulliparous and symptomatic premenopausal women with pelvic organ prolapse in dynamic MRI: a feasibility study comparing midsagittal single-slice with multi-slice sequences.
- Author
-
Ghafoor S, Beintner-Skawran SM, Stöckli G, Betschart C, and Reiner CS
- Subjects
- Humans, Female, Prospective Studies, Feasibility Studies, Pelvis, Magnetic Resonance Imaging, Pelvic Organ Prolapse diagnostic imaging
- Abstract
Purpose: To compare multi-slice (MS) MRI sequences of the pelvis acquired at rest and straining to dynamic midsagittal single-slice (SS) sequences for the assessment of pelvic organ prolapse (POP)., Methods: This IRB-approved prospective single-center feasibility study included 23 premenopausal symptomatic patients with POP and 22 asymptomatic nulliparous volunteers. MRI of the pelvis at rest and straining was performed with midsagittal SS and MS sequences. Straining effort, visibility of organs and POP grade were scored on both. Organ points (bladder, cervix, anorectum) were measured. Differences between SS and MS sequences were compared with Wilcoxon test., Results: Straining effort was good in 84.4% on SS and in 64.4% on MS sequences (p = 0.003). Organ points were always visible on MS sequences, whereas the cervix was not fully visible in 31.1-33.3% on SS sequences. At rest, there were no statistically significant differences of organ point measurements between SS and MS sequences in symptomatic patients. At straining, positions of bladder, cervix, and anorectum were + 1.1 cm (± 1.8 cm), - 0.7 cm (± 2.9 cm), and + 0.7 cm (± 1.3 cm) on SS and + 0.4 mm (± 1.7 cm), - 1.4 cm (± 2.6 cm), and + 0.4 cm (± 1.3 cm) on MS sequences (p < 0.05). Only 2 cases of higher-grade POP were missed on MS sequences (both with poor straining effort)., Conclusion: MS sequences increase the visibility of organ points compared to SS sequences. Dynamic MS sequences can depict POP if images are acquired with sufficient straining effort. Further work is needed to optimize the depiction of the maximum straining effort with MS sequences., (© 2023. The Author(s).)
- Published
- 2023
- Full Text
- View/download PDF
21. Performance of two-dimensional shear wave elastography and transient elastography compared to liver biopsy for staging of liver fibrosis.
- Author
-
Kovatsch A, Honcharova-Biletska H, Segna D, Steigmiller K, Blümel S, Deibel RA, Kühlewindt T, Leinenkugel G, Müller S, Furrer E, Schawkat K, Reiner CS, Weber A, Müllhaupt B, Scharl M, Gubler C, and Jüngst C
- Subjects
- Adult, Humans, Liver Cirrhosis diagnostic imaging, Liver Cirrhosis pathology, Liver diagnostic imaging, Liver pathology, Fibrosis, Biopsy, Elasticity Imaging Techniques methods, Liver Diseases
- Abstract
Background: Staging of liver fibrosis traditionally relied on liver histology; however, transient elastography (TE) and more recently two-dimensional shear wave elastography (2D-SWE) evolved to noninvasive alternatives. Hence, we evaluated the diagnostic accuracy of 2D-SWE assessed by the Canon Aplio i800 ultrasound system using liver biopsy as reference and compared the performance to TE., Methods: In total, 108 adult patients with chronic liver disease undergoing liver biopsy, 2D-SWE and TE were enrolled prospectively at the University Hospital Zurich. Diagnostic accuracies were evaluated using the area under the receiver operating characteristic (AUROC) analysis, and optimal cut-off values by Youden's index., Results: Diagnostic accuracy of 2D-SWE was good for significant (≥F2; AUROC 85.2%, 95% confidence interval (95%CI):76.2-91.2%) as well as severe fibrosis (≥F3; AUROC 86.8%, 95%CI: 78.1-92.4%) and excellent for cirrhosis (AUROC 95.6%, 95%CI: 89.9-98.1%), compared to histology. TE performed equally well (significant fibrosis: 87.5%, 95%CI: 77.7-93.3%; severe fibrosis: 89.7%, 95%CI: 82.0-94.3%; cirrhosis: 96%, 95%CI: 90.4-98.4%), and accuracy was not statistically different to 2D-SWE. 2D-SWE optimal cut-off values were 6.5, 9.8 and 13.1 kPa for significant fibrosis, severe fibrosis and cirrhosis, respectively., Conclusions: Performance of 2D-SWE was good to excellent and well comparable with TE, supporting the application of this 2D-SWE system in the diagnostic workup of chronic liver disease., (© 2023 The Authors. European Journal of Clinical Investigation published by John Wiley & Sons Ltd on behalf of Stichting European Society for Clinical Investigation Journal Foundation.)
- Published
- 2023
- Full Text
- View/download PDF
22. CT/MRI and CEUS LI-RADS Major Features Association with Hepatocellular Carcinoma: Individual Patient Data Meta-Analysis.
- Author
-
van der Pol CB, McInnes MDF, Salameh JP, Levis B, Chernyak V, Sirlin CB, Bashir MR, Allen BC, Burke LMB, Choi JY, Choi SH, Forner A, Fraum TJ, Giamperoli A, Jiang H, Joo I, Kang Z, Kierans AS, Kang HJ, Khatri G, Kim JH, Kim MJ, Kim SY, Kim YY, Kwon H, Lee JM, Lewis SC, McGinty KA, Mulazzani L, Park MS, Piscaglia F, Podgórska J, Reiner CS, Ronot M, Rosiak G, Song B, Song JS, Tang A, Terzi E, Wang J, Wang W, Wilson SR, and Yokoo T
- Published
- 2023
- Full Text
- View/download PDF
23. Assessment of hepatic fibrosis and inflammation with look-locker T1 mapping and magnetic resonance elastography with histopathology as reference standard.
- Author
-
von Ulmenstein S, Bogdanovic S, Honcharova-Biletska H, Blümel S, Deibel AR, Segna D, Jüngst C, Weber A, Kuntzen T, Gubler C, and Reiner CS
- Subjects
- Fibrosis, Humans, Inflammation diagnostic imaging, Inflammation pathology, Liver diagnostic imaging, Liver pathology, Liver Cirrhosis diagnostic imaging, Liver Cirrhosis pathology, Magnetic Resonance Imaging methods, Reference Standards, Elasticity Imaging Techniques methods
- Abstract
Purpose: To compare the diagnostic performance of T1 mapping and MR elastography (MRE) for staging of hepatic fibrosis and grading inflammation with histopathology as standard of reference., Methods: 68 patients with various liver diseases undergoing liver biopsy for suspected fibrosis or with an established diagnosis of cirrhosis prospectively underwent look-locker inversion recovery T1 mapping and MRE. T1 relaxation time and liver stiffness (LS) were measured by two readers. Hepatic fibrosis and inflammation were histopathologically staged according to a standardized fibrosis (F0-F4) and inflammation (A0-A2) score. For statistical analysis, independent t test, and Mann-Whitney U test and ROC analysis were performed, the latter to determine the performance of T1 mapping and MRE for fibrosis staging and inflammation grading, as compared to histopathology., Results: Histopathological analysis diagnosed 9 patients with F0 (13.2%), 21 with F1 (30.9%), 11 with F2 (16.2%), 10 with F3 (14.7%), and 17 with F4 (25.0%). Both T1 mapping and MRE showed significantly higher values for patients with significant fibrosis (F0-1 vs. F2-4; T1 mapping p < 0.0001, MRE p < 0.0001) as well as for patients with severe fibrosis or cirrhosis (F0-2 vs. F3-4; T1 mapping p < 0.0001, MRE p < 0.0001). T1 values and MRE LS were significantly higher in patients with inflammation (A0 vs. A1-2, both p = 0.01). T1 mapping showed a tendency toward lower diagnostic performance without statistical significance for significant fibrosis (F2-4) (AUC 0.79 vs. 0.91, p = 0.06) and with a significant difference compared to MRE for severe fibrosis (F3-4) (AUC 0.79 vs. 0.94, p = 0.03). For both T1 mapping and MRE, diagnostic performance for diagnosing hepatic inflammation (A1-2) was low (AUC 0.72 vs. 0.71, respectively)., Conclusion: T1 mapping is able to diagnose hepatic fibrosis, however, with a tendency toward lower diagnostic performance compared to MRE and thus may be used as an alternative to MRE for diagnosing hepatic fibrosis, whenever MRE is not available or likely to fail due to intrinsic factors of the patient. Both T1 mapping and MRE are probably not sufficient as standalone methods to diagnose hepatic inflammation with relatively low diagnostic accuracy., (© 2022. The Author(s).)
- Published
- 2022
- Full Text
- View/download PDF
24. Imaging features of COVID-19-associated secondary sclerosing cholangitis on magnetic resonance cholangiopancreatography: a retrospective analysis.
- Author
-
Ghafoor S, Germann M, Jüngst C, Müllhaupt B, Reiner CS, and Stocker D
- Abstract
Background: Despite emerging reports of secondary sclerosing cholangitis (SSC) in critically ill COVID-19 patients little is known about its imaging findings. It presents as delayed progressive cholestatic liver injury with risk of progression to cirrhosis. Diagnosis cannot be made based on clinical presentation and laboratory markers alone. Magnetic resonance imaging (MRI) and magnetic resonance cholangiopancreatography (MRCP) can aid in the diagnosis. The aim of this study was to describe MRI/MRCP imaging features of COVID-19-associated SSC., Results: Seventeen patients (mean age 60.5 years, 15 male) who underwent MRI/MRCP were included. All had been admitted to intensive care unit (ICU) (median duration of ICU stay 10 weeks, range, 2-28 weeks) and developed acute respiratory distress syndrome requiring mechanical ventilation. On imaging, all patients had intrahepatic bile duct strictures and 10 (58.8%) had associated upstream dilatation. Intrahepatic bile duct beading was seen in 14 cases (82.3%). Only one patient (5.9%) had extrahepatic bile duct stricturing. Patchy arterial phase hyperenhancement and high signal on T2- and diffusion-weighted images were seen in 7 cases (53.8%) and 9 cases (52.9%), respectively. Biliary casts were seen in 2 cases (11.8%). Periportal lymphadenopathy and vascular complications were not seen., Conclusion: On MRI/MRCP, COVID-19-associated SSC presents with multiple intrahepatic bile duct strictures with or without upstream dilatation and intrahepatic bile duct beading. Surrounding hepatic parenchymal changes including alterations in enhancement and T2 signal are common. The extrahepatic biliary tree was typically spared and periportal lymphadenopathy was missing in all patients., (© 2022. The Author(s).)
- Published
- 2022
- Full Text
- View/download PDF
25. Prediction of benzimidazole therapy duration with PET/CT in inoperable patients with alveolar echinococcosis.
- Author
-
Husmann L, Gruenig H, Reiner CS, Deibel A, Ledergerber B, Liberini V, Skawran S, Muehlematter UJ, Messerli M, Hasse B, Muellhaupt B, and Huellner MW
- Subjects
- Benzimidazoles therapeutic use, Echinococcosis, Humans, Retrospective Studies, Duration of Therapy, Positron Emission Tomography Computed Tomography
- Abstract
Alveolar echinococcosis is a rare parasitic disease, most frequently affecting the liver, as a slow-growing tumor-like lesion. If inoperable, long-term benzimidazole therapy is required, which is associated with high healthcare costs and occasionally with increased morbidity. The aim of our study was to determine the role
18 F-fluorodeoxyglucose (FDG) positron emission tomography/computed tomography (PET/CT) in staging of patients with alveolar echinococcosis and to identify quantitative imaging parameters related to patient outcome and/or duration of benzimidazole therapy. In this single-center retrospective cohort study, 47 PET/CT performed for staging in patients with confirmed alveolar echinococcosis were analysed. In 43 patients (91%) benzimidazole therapy was initiated and was successfully stopped after a median of 870 days (766-2517) in 14/43 patients (33%). In inoperable patients, tests for trend of survivor functions displayed clear trends for longer benzimidazole therapy duration (p = 0.05; n = 25), and for longer time intervals to reach non-detectable serum concentration of Em-18 antibodies (p = 0.01, n = 15) across tertiles of SUVratio (maximum standardized uptake value in the echinococcus manifestation compared to normal liver tissue). Hence, in inoperable patients with alveolar echinococcosis, PET/CT performed for staging may predict the duration of benzimidazole therapy., (© 2022. The Author(s).)- Published
- 2022
- Full Text
- View/download PDF
26. Follow-up PET/CT of alveolar echinococcosis: Comparison of metabolic activity and immunodiagnostic testing.
- Author
-
Husmann L, Deibel A, Skawran S, Ledergerber B, Muehlematter UJ, Hasse B, Huellner MW, Reiner CS, and Muellhaupt B
- Subjects
- Benzimidazoles, Fluorodeoxyglucose F18, Follow-Up Studies, Humans, Positron-Emission Tomography methods, Radiopharmaceuticals, Retrospective Studies, Echinococcosis diagnostic imaging, Positron Emission Tomography Computed Tomography methods
- Abstract
Purpose: To investigate the potential role of follow-up 18F-fluorodeoxyglucose (FDG) positron emission tomography/computed tomography (PET/CT) in therapy control of inoperable patients with alveolar echinococcosis., Materials and Methods: In this single-center retrospective cohort study, 48 PET/CT of 16 patients with confirmed alveolar echinococcosis were analysed. FDG-uptake of the most active echinococcosis manifestation was measured (i.e., maximum standardized uptake value (SUVmax) and in relation to background activity in normal liver tissue (SUVratio)) and compared to immunodiagnostic testing. For clinical patient follow-up, patient demographics, laboratory data, including E. granulosus hydatid fluid (EgHF) antibody units (AU) as well as clinical and treatment information were assessed for all patients at the time of PET/CT, and at the last recorded clinical visit., Results: Metabolic activity of PET/CT measured in the echinococcosis manifestation was significantly correlated with EgHF AU (p < 0.001). The differences in metabolic activity of echinococcosis manifestations between two consecutive PET/CT examinations of the same patient and differences in EgHF AU in the respective time intervals displayed a significant positive correlation (p = 0.01). A trend for a more rapid decline in SUVratio liver over time was found in patients who stopped benzimidazole therapy versus patients who did not stop therapy (p = 0.059)., Conclusion: In inoperable patients with alveolar echinococcosis, the course of metabolic activity in follow-up PET/CT is associated to the course EgHF antibody levels. Both parameters may potentially be used to evaluate the course of the disease and potentially predict the duration of benzimidazole therapy., Competing Interests: All authors declare no conflict of interest.
- Published
- 2022
- Full Text
- View/download PDF
27. Characteristics and Clinical Course of Alveolar Echinococcosis in Patients with Immunosuppression-Associated Conditions: A Retrospective Cohort Study.
- Author
-
Deibel A, Meyer Zu Schwabedissen C, Husmann L, Grimm F, Deplazes P, Reiner CS, and Müllhaupt B
- Abstract
Objectives: Since the change in the millennium, an increase in cases of alveolar echinococcosis (AE) has been observed in endemic European countries. Previous studies indicate that a significant proportion of the new AE cases have an immunosuppression-associated condition (IAC). The aim of the current study was to determine how IACs impact the number of new AE diagnoses per year and the characteristics of AE at diagnosis and its clinical course at our center., Methods: Retrospective analysis of 189 patients with AE diagnosed between 2000 and 2021 and participating in the Zurich Echinococcosis Cohort Study (ZECS) included clinical characteristics of AE at diagnosis and report of an IAC, as well as the clinical course during follow-up., Results: Of 189 patients participating in this study, 38 had an IAC reported at, or shortly after, AE diagnosis. Over time, there was a steeper increase in the number of newly diagnosed AE patients without an IAC than the number of patients with IAC. Patients with an IAC were older at diagnosis, more frequently had an incidental finding of AE, smaller mean lesion size, and negative Em18 serology. All but two showed favorable outcomes on the last follow-up., Conclusion: IACs have little impact on the increase in new AE cases, as well as on the extent of the disease at diagnosis and clinical course.
- Published
- 2022
- Full Text
- View/download PDF
28. Quantitative and qualitative evaluation of liver metastases with intraprocedural cone beam CT prior to transarterial radioembolization as a predictor of treatment response.
- Author
-
Messmer F, Zgraggen J, Kobe A, Chaykovska L, Puippe G, Reiner CS, and Pfammatter T
- Abstract
Purpose: To investigate, by quantitative and qualitative enhancement measurements, the correlation between tumor enhancement on cone beam computed tomography (CBCT) images and treatment response at 6 months in patients undergoing transarterial radioembolization (TARE) for liver metastases., Materials and Methods: 36 patients (56% male; median age 62.5 years) with 104 metastases were retrospectively included. Quantitative and qualitative enhancement of liver metastases were evaluated on CBCT images before TARE. Quantitative analysis consisted of lesion enhancement measurements (ROI HU lesion - ROI HU relative to inferior vena cava). Qualitative analysis consisted of subjective enhancement pattern analysis (diffuse, sparse, rim-like or non-enhancing). Morphologic tumor response was evaluated according to RECIST 1.1 criteria on follow-up CT or MR imaging., Results: At a mean follow up of 6.5 ± 3.7 months, progressive disease (PD) was found in 4 patients, partial response (PR) in 11 and stable disease (SD) in 21. Relative lesion enhancement was significantly different between these groups (-37.5±154.2 HU vs. 103.8±93.4 vs. 181±144 HU in PD vs. SD vs. PR group, respectively; p<0.01). ROC analysis of relative lesion enhancement to predict progressive disease showed an area under the curve of 0.86 (p<0.01). For qualitative lesion enhancement analysis, no difference between groups was found., Conclusion: Quantitative enhancement measurements derived from intraprocedural contrast enhanced CBCT may identify responders to TARE in patients with liver metastases., Competing Interests: The authors report no declarations of interest., (© 2022 The Authors.)
- Published
- 2022
- Full Text
- View/download PDF
29. Normal width of the linea alba, prevalence, and risk factors for diastasis recti abdominis in adults, a cross-sectional study.
- Author
-
Kaufmann RL, Reiner CS, Dietz UA, Clavien PA, Vonlanthen R, and Käser SA
- Subjects
- Adolescent, Adult, Aged, Aged, 80 and over, Cross-Sectional Studies, Female, Herniorrhaphy, Humans, Middle Aged, Pregnancy, Prevalence, Retrospective Studies, Risk Factors, Young Adult, Diastasis, Muscle, Rectus Abdominis diagnostic imaging
- Abstract
Aim: The prevalence and definition of diastasis recti abdominis (DRA) is under debate. This retrospective cross-sectional study evaluated the interrectal distance and the prevalence of DRA in computed tomography (CT) in an asymptomatic population., Materials and Methods: Patients undergoing CT scans for suspected appendicitis or kidney stones from 01/2016 to 12/2018 were screened retrospectively to participate. A study population with equal distribution according to gender and age (18-90 years) was generated (n = 329 patients) and the interrectal distance was measured at six reference points., Results: DRA (defined as > 2 cm at 3 cm above the umbilicus) was present in 57% of the population. The 80th percentile of the interrectal distance was 10 mm at the xiphoid (median 3 mm, 95% confidence interval (CI) 0-19 mm), 27 mm halfway from xiphoid to umbilicus (median 17 mm, 95% CI 0-39 mm), 34 mm at 3 cm above the umbilicus (median 22 mm, 95% CI 0-50 mm), 32 mm at the umbilicus (median 25 mm, 95% CI 0-45 mm), 25 mm at 2 cm below the umbilicus (median 14 mm, 95% CI 0-39 mm), and 4 mm halfway from umbilicus to pubic symphysis (median 0 mm, 95% CI 0-19 mm). In the multivariate analysis, higher age (p = 0.001), increased body mass index (p < 0.001), and parity (p < 0.037) were independent risk factors for DRA, while split xiphoid, tobacco abuse, and umbilical hernia were not., Conclusion: The prevalence of DRA is much higher than commonly estimated (57%). The IRD 3 cm above the umbilicus may be considered normal up to 34 mm. To avoid over-treatment, the definition of DRA should be revised., (© 2021. The Author(s).)
- Published
- 2022
- Full Text
- View/download PDF
30. CT/MRI and CEUS LI-RADS Major Features Association with Hepatocellular Carcinoma: Individual Patient Data Meta-Analysis.
- Author
-
van der Pol CB, McInnes MDF, Salameh JP, Levis B, Chernyak V, Sirlin CB, Bashir MR, Allen BC, Burke LMB, Choi JY, Choi SH, Forner A, Fraum TJ, Giamperoli A, Jiang H, Joo I, Kang Z, Kierans AS, Kang HJ, Khatri G, Kim JH, Kim MJ, Kim SY, Kim YY, Kwon H, Lee JM, Lewis SC, McGinty KA, Mulazzani L, Park MS, Piscaglia F, Podgórska J, Reiner CS, Ronot M, Rosiak G, Song B, Song JS, Tang A, Terzi E, Wang J, Wang W, Wilson SR, and Yokoo T
- Subjects
- Contrast Media, Diagnosis, Differential, Humans, Magnetic Resonance Imaging methods, Sensitivity and Specificity, Tomography, X-Ray Computed methods, Ultrasonography methods, Carcinoma, Hepatocellular diagnostic imaging, Liver Neoplasms diagnostic imaging
- Abstract
Background The Liver Imaging Reporting and Data System (LI-RADS) assigns a risk category for hepatocellular carcinoma (HCC) to imaging observations. Establishing the contributions of major features can inform the diagnostic algorithm. Purpose To perform a systematic review and individual patient data meta-analysis to establish the probability of HCC for each LI-RADS major feature using CT/MRI and contrast-enhanced US (CEUS) LI-RADS in patients at high risk for HCC. Materials and Methods Multiple databases (MEDLINE, Embase, Cochrane Central Register of Controlled Trials, and Scopus) were searched for studies from January 2014 to September 2019 that evaluated the accuracy of CT, MRI, and CEUS for HCC detection using LI-RADS (CT/MRI LI-RADS, versions 2014, 2017, and 2018; CEUS LI-RADS, versions 2016 and 2017). Data were centralized. Clustering was addressed at the study and patient levels using mixed models. Adjusted odds ratios (ORs) with 95% CIs were determined for each major feature using multivariable stepwise logistic regression. Risk of bias was assessed using Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS-2) (PROSPERO protocol: CRD42020164486). Results A total of 32 studies were included, with 1170 CT observations, 3341 MRI observations, and 853 CEUS observations. At multivariable analysis of CT/MRI LI-RADS, all major features were associated with HCC, except threshold growth (OR, 1.6; 95% CI: 0.7, 3.6; P = .07). Nonperipheral washout (OR, 13.2; 95% CI: 9.0, 19.2; P = .01) and nonrim arterial phase hyperenhancement (APHE) (OR, 10.3; 95% CI: 6.7, 15.6; P = .01) had stronger associations with HCC than enhancing capsule (OR, 2.4; 95% CI: 1.7, 3.5; P = .03). On CEUS images, APHE (OR, 7.3; 95% CI: 4.6, 11.5; P = .01), late and mild washout (OR, 4.1; 95% CI: 2.6, 6.6; P = .01), and size of at least 20 mm (OR, 1.6; 95% CI: 1.04, 2.5; P = .04) were associated with HCC. Twenty-five studies (78%) had high risk of bias due to reporting ambiguity or study design flaws. Conclusion Most Liver Imaging Reporting and Data System major features had different independent associations with hepatocellular carcinoma; for CT/MRI, arterial phase hyperenhancement and washout had the strongest associations, whereas threshold growth had no association. © RSNA, 2021 Online supplemental material is available for this article.
- Published
- 2022
- Full Text
- View/download PDF
31. Evaluation of a structured treatment discontinuation in patients with inoperable alveolar echinococcosis on long-term benzimidazole therapy: A retrospective cohort study.
- Author
-
Deibel A, Stocker D, Meyer Zu Schwabedissen C, Husmann L, Kronenberg PA, Grimm F, Deplazes P, Reiner CS, and Müllhaupt B
- Subjects
- Adult, Aged, Antibodies, Helminth blood, Cohort Studies, Echinococcosis diagnostic imaging, Female, Humans, Male, Middle Aged, Positron-Emission Tomography, Retrospective Studies, Treatment Outcome, Anthelmintics therapeutic use, Benzimidazoles therapeutic use, Echinococcosis drug therapy, Withholding Treatment
- Abstract
Objectives: Alveolar echinococcosis (AE) is an orphan zoonosis of increasing concern in endemic areas, including Europe. It frequently presents in an advanced, inoperable stage, that requires life-long parasitostatic benzimidazole therapy. In some patients, long-term therapy leads to negative anti-Em18 antibody ELISA and PET. It is disputed, whether these patients are truly cured and treatment can be safely discontinued. Our aim was to retrospectively assess long-term outcome of 34 patients with inoperable AE who participated in a previous study to determine feasibility of benzimidazole treatment cessation., Methods: Retrospective analysis of medical charts was undertaken in all 34 AE patients who participated in our previous study. Of particular interest were AE recurrence or other reasons for re-treatment in patients who stopped benzimidazole therapy and whether baseline clinical and laboratory parameters help identify of patients that might qualifiy for treatment cessation. Additionally, volumetric measurement of AE lesions on contrast-enhanced cross-sectional imaging was performed at baseline and last follow-up in order to quantify treatment response., Results: 12 of 34 patients stopped benzimidazole therapy for a median of 131 months. 11 of these patients showed stable or regressive AE lesions as determined by volumetric measurement. One patient developed progressive lesions with persistently negative anti-Em18 antibody ELISA but slight FDG-uptake in repeated PET imaging. At baseline, patients who met criteria for treatment cessation demonstrated higher lymphocyte count and lower total IgE., Conclusion: Treatment cessation is feasible in inoperable AE patients, who demonstrate negative anti-Em18 antibody ELISA and PET on follow-up. Close monitoring including sectional imaging is strongly advised., Competing Interests: The authors have declared that no competing interests exist.
- Published
- 2022
- Full Text
- View/download PDF
32. Secondary sclerosing cholangitis as cause of persistent jaundice in patients with severe COVID-19.
- Author
-
Bütikofer S, Lenggenhager D, Wendel Garcia PD, Maggio EM, Haberecker M, Reiner CS, Brüllmann G, Buehler PK, Gubler C, Müllhaupt B, Jüngst C, and Morell B
- Subjects
- Critical Illness, Humans, Intensive Care Units, Retrospective Studies, SARS-CoV-2, COVID-19, Cholangitis, Sclerosing complications, Jaundice
- Abstract
Background & Aims: Little is known about cholestasis, including its most severe variant secondary sclerosing cholangitis (SSC), in critically ill patients with coronavirus disease 19 (COVID-19). In this study, we analysed the occurrence of cholestatic liver injury and SSC, including clinical, serological, radiological and histopathological findings., Methods: We conducted a retrospective single-centre analysis of all consecutive patients admitted to the intensive care unit (ICU) as a result of severe COVID-19 at the University Hospital Zurich to describe cholestatic injury in these patients. The findings were compared to a retrospective cohort of patients with severe influenza A., Results: A total of 34 patients with severe COVID-19 admitted to the ICU were included. Of these, 14 patients (41%) had no cholestasis (group 0), 11 patients (32%, group 1) developed mild and 9 patients (27%, group 2) severe cholestasis. Patients in group 2 had a more complicated disease course indicated by significantly longer ICU stay (median 51 days, IQR 25-86.5) than the other groups (group 0: median 9.5 days, IQR 3.8-18.3, P = .001; and group 1: median 16 days, IQR 8-30, P < .05 respectively). Four patients in group 2 developed SSC compared to none in the influenza A cohort. The available histopathological findings suggest an ischaemic damage to the perihilar bile ducts., Conclusions: The development of SSC represents an important complication of critically ill COVID-19 patients and needs to be considered in the diagnostic work up in prolonged cholestasis. The occurrence of SSC is of interest in the ongoing pandemic since it is associated with considerable morbidity and mortality., (© 2021 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.)
- Published
- 2021
- Full Text
- View/download PDF
33. Can magnetic resonance imaging radiomics of the pancreas predict postoperative pancreatic fistula?
- Author
-
Skawran SM, Kambakamba P, Baessler B, von Spiczak J, Kupka M, Müller PC, Moeckli B, Linecker M, Petrowsky H, and Reiner CS
- Subjects
- Humans, Magnetic Resonance Imaging, Pancreas diagnostic imaging, Pancreas surgery, ROC Curve, Retrospective Studies, Pancreatic Fistula diagnostic imaging, Pancreatic Fistula etiology, Pancreaticoduodenectomy
- Abstract
Objectives: To evaluate whether a magnetic resonance imaging (MRI) radiomics-based machine learning classifier can predict postoperative pancreatic fistula (POPF) after pancreaticoduodenectomy (PD) and to compare its performance to T1 signal intensity ratio (T1 SIratio)., Methods: Sixty-two patients who underwent 3 T MRI before PD between 2008 and 2018 were retrospectively analyzed. POPF was graded and split into clinically relevant POPF (CR-POPF) vs. biochemical leak or no POPF. On T1- and T2-weighted images, 2 regions of interest were placed in the pancreatic corpus and cauda. 173 radiomics features were extracted using pyRadiomics. Additionally, the pancreas-to-muscle T1 SIratio was measured. The dataset was augmented and split into training (70 %) and test sets (30 %). A Boruta algorithm was used for feature reduction. For prediction of CR-POPF models were built using a gradient-boosted tree (GBT) and logistic regression from the radiomics features, T1 SIratio and a combination of the two. Diagnostic accuracy of the models was compared using areas under the receiver operating characteristics curve (AUCs)., Results: Five most important radiomics features were identified for prediction of CR-POPF. A GBT using these features achieved an AUC of 0.82 (95 % Confidence Interval [CI]: 0.74 - 0.89) when applied on the original (non-augmented) dataset. Using T1 SIratio, a GBT model resulted in an AUC of 0.75 (CI: 0.63 - 0.84) and a logistic regression model delivered an AUC of 0.75 (CI: 0.63 - 0.84). A GBT model combining radiomics features and T1 SIratio resulted in an AUC of 0.90 (CI 0.84 - 0.95)., Conclusion: MRI-radiomics with routine sequences provides promising prediction of CR-POPF., (Copyright © 2021 Elsevier B.V. All rights reserved.)
- Published
- 2021
- Full Text
- View/download PDF
34. Role of intravoxel incoherent motion parameters in gastroesophageal cancer: relationship with 18F-FDG-positron emission tomography, computed tomography perfusion and magnetic resonance perfusion imaging parameters.
- Author
-
Schawkat K, Sah BR, Ter Voert EE, Delso G, Wurnig M, Becker AS, Leibl S, Schneider PM, Reiner CS, Huellner MW, and Veit-Haibach P
- Subjects
- Adult, Aged, Aged, 80 and over, Blood Circulation, Female, Humans, Magnetic Resonance Imaging, Male, Middle Aged, Multimodal Imaging, Perfusion Imaging, Positron Emission Tomography Computed Tomography, Tumor Burden, Esophageal Neoplasms diagnostic imaging, Esophageal Squamous Cell Carcinoma diagnostic imaging, Fluorodeoxyglucose F18 chemistry, Radiopharmaceuticals chemistry
- Abstract
Background: Identification of pretherapeutic predictive markers in gastro-esophageal cancer is essential for individual-oriented treatment. This study evaluated the relationship of multimodality parameters derived from intravoxel incoherent motion method (IVIM), 18F-FDG-positron emission tomography (PET), computed tomography (CT) perfusion and dynamic contrast enhanced magnetic resonance imaging (MRI) in patients with gastro-esophageal cancer and investigated their histopathological correlation., Methods: Thirty-one consecutive patients (28 males; median age 63.9 years; range 37-84 years) with gastro-esophageal adenocarcinoma (N.=22) and esophageal squamous cell carcinoma (N.=9) were analyzed. IVIM parameters: pseudodiffusion (D*), perfusion fraction (fp), true diffusion (D) and the threshold b-value (bval); PET-parameters: SUV
max , metabolic tumor volume (MTV) and total lesion glycolysis (TLG); CT perfusion parameters: blood flow (BF), blood volume (BV) and mean transit time (MTT); and MR perfusion parameters: time to enhance, positive enhancement integral, time-to-peak (TTP), maximum-slope-of-increase, and maximum-slope-of-decrease were determined, and correlated to each other and to histopathology., Results: IVIM and PET parameters showed significant negative correlations: MTV and bval (rs =-0.643, P=0.002), TLG and bval (rs =-0.699, P<0.01) and TLG and fp (rs =-0.577, P=0.006). Positive correlation was found for TLG and D (rs =0.705, P=0.000). Negative correlation was found for bval and staging (rs =0.590, P=0.005). Positive correlation was found for positive enhancement interval and BV (rs =0.547, P=0.007), BF and regression index (rs =0.753, P=0.005) and for time-to-peak and staging (rs =0.557, P=0.005)., Conclusions: IVIM parameters (bval, fp, D) provide quantitative information and correlate with PET parameters (MTV, TLG) and staging. IVIM might be a useful tool for additional characterization of gastro-esophageal cancer.- Published
- 2021
- Full Text
- View/download PDF
35. Choices of Therapeutic Strategies for Colorectal Liver Metastases Among Expert Liver Surgeons: A Throw of the Dice?
- Author
-
Ignatavicius P, Oberkofler CE, Chapman WC, DeMatteo RP, Clary BM, D'Angelica MI, Tanabe KK, Hong JC, Aloia TA, Pawlik TM, Hernandez-Alejandro R, Shah SA, Vauthey JN, Torzilli G, Lang H, Line PD, Soubrane O, Pinto-Marques H, Robles-Campos R, Boudjema K, Lodge P, Adam R, Toso C, Serrablo A, Aldrighetti L, DeOliveira ML, Dutkowski P, Petrowsky H, Linecker M, Reiner CS, Braun J, Alikhanov R, Barauskas G, Chan ACY, Dong J, Kokudo N, Yamamoto M, Kang KJ, Fong Y, Rela M, De Aretxabala X, De Santibañes E, Mercado MÁ, Andriani OC, Torres OJM, Pinna AD, and Clavien PA
- Subjects
- Adult, Consensus, Female, Humans, Male, Middle Aged, Colorectal Neoplasms pathology, Decision Making, Hepatectomy methods, Liver Neoplasms secondary, Liver Neoplasms surgery, Practice Patterns, Physicians' statistics & numerical data
- Abstract
Objective: To test the degree of agreement in selecting therapeutic options for patients suffering from colorectal liver metastasis (CRLM) among surgical experts around the globe., Summary/background: Only few areas in medicine have seen so many novel therapeutic options over the past decades as for liver tumors. Significant variations may therefore exist regarding the choices of treatment, even among experts, which may confuse both the medical community and patients., Methods: Ten cases of CRLM with different levels of complexity were presented to 43 expert liver surgeons from 23 countries and 4 continents. Experts were defined as experienced surgeons with academic contributions to the field of liver tumors. Experts provided information on their medical education and current practice in liver surgery and transplantation. Using an online platform, they chose their strategy in treating each case from defined multiple choices with added comments. Inter-rater agreement among experts and cases was calculated using free-marginal multirater kappa methodology. A similar, but adjusted survey was presented to 60 general surgeons from Asia, Europe, and North America to test their attitude in treating or referring complex patients to expert centers., Results: Thirty-eight (88%) experts completed the evaluation. Most of them are in leading positions (92%) with a median clinical experience of 25 years. Agreement on therapeutic strategies among them was none to minimal in more than half of the cases with kappa varying from 0.00 to 0.39. Many general surgeons may not refer the complex cases to expert centers, including in Europe, where they also engage in complex liver surgeries., Conclusions: Considerable inconsistencies of decision-making exist among expert surgeons when choosing a therapeutic strategy for CRLM. This might confuse both patients and referring physicians and indicate that an international high-level consensus statements and widely accepted guidelines are needed.
- Published
- 2020
- Full Text
- View/download PDF
36. Reduced and standard field-of-view diffusion weighted imaging in patients with rectal cancer at 3 T-Comparison of image quality and apparent diffusion coefficient measurements.
- Author
-
Attenberger UI, Tavakoli A, Stocker D, Stieb S, Riesterer O, Turina M, Schoenberg SO, Pilz L, and Reiner CS
- Subjects
- Adult, Aged, Artifacts, Female, Humans, Image Enhancement, Lymph Nodes diagnostic imaging, Male, Middle Aged, Prospective Studies, Diffusion Magnetic Resonance Imaging methods, Echo-Planar Imaging methods, Imaging, Three-Dimensional methods, Rectal Neoplasms diagnostic imaging
- Abstract
Purpose: To compare a zoomed EPI-DWI (z-EPI) with a standard EPI-DWI (s-EPI) in the primary diagnostics of rectal cancer and assess its potential of reduced image artifacts., Method: 22 therapy-naïve patients with rectal cancer underwent rectal MRI at a 3 T-system. The protocols consisted of a z-EPI DWI and s-EPI DWI sequence. Images were assessed by two independent and experienced readers regarding overall image quality and artifacts on a 5-point Likert scale, as well as overall sequence preference. In a lesion-based analysis, tumor and lymph node detection were rated on a 4-point Likert scale. Apparent diffusion coefficient (ADC) measurements were performed., Results: Overall Image quality score for z-EPI and s-EPI showed no statistically significant differences (p = 0.80/0.54, reader 1/2) with a median score of 4 ("good" image quality) for both sequences. The image quality preference rank for z-EPI and s-EPI was given the category 'no preference' in 64 % (reader 1) and 50 % (reader 2). Most artifact-related scores (susceptibility, motion and distortion) did not show reproducible significant differences between z-EPI and s-EPI. The two sequences exhibited comparable, mostly good and excellent quality scores for tumor and lymph node detection (p = 0.19-0.99). ADC values were significantly lower for z-EPI than for s-EPI (p = 0.001/0.002, reader 1/2) with good agreement of ADC measurements between both readers., Conclusion: Our data showed comparable image quality and lesion detection for the z-EPI and the s-EPI sequence in MRI of rectal cancer, whereas the mean ADC of the tumor was significantly lower in z-EPI compared to s-EPI., (Copyright © 2020. Published by Elsevier B.V.)
- Published
- 2020
- Full Text
- View/download PDF
37. Diagnostic accuracy of texture analysis and machine learning for quantification of liver fibrosis in MRI: correlation with MR elastography and histopathology.
- Author
-
Schawkat K, Ciritsis A, von Ulmenstein S, Honcharova-Biletska H, Jüngst C, Weber A, Gubler C, Mertens J, and Reiner CS
- Subjects
- Biopsy, Female, Humans, Male, Middle Aged, Prospective Studies, ROC Curve, Elasticity Imaging Techniques methods, Liver diagnostic imaging, Liver Cirrhosis diagnosis, Machine Learning, Magnetic Resonance Imaging methods
- Abstract
Objectives: To compare the diagnostic accuracy of texture analysis (TA)-derived parameters combined with machine learning (ML) of non-contrast-enhanced T1w and T2w fat-saturated (fs) images with MR elastography (MRE) for liver fibrosis quantification., Methods: In this IRB-approved prospective study, liver MRIs of participants with suspected chronic liver disease who underwent liver biopsy between August 2015 and May 2018 were analyzed. Two readers blinded to clinical and histopathological findings performed TA. The participants were categorized into no or low-stage (0-2) and high-stage (3-4) fibrosis groups. Confusion matrices were calculated using a support vector machine combined with principal component analysis. The diagnostic accuracy of ML-based TA of liver fibrosis and MRE was assessed by area under the receiver operating characteristic curves (AUC). Histopathology served as reference standard., Results: A total of 62 consecutive participants (40 men; mean age ± standard deviation, 48 ± 13 years) were included. The accuracy of TA and ML on T1w was 85.7% (95% confidence interval [CI] 63.7-97.0) and 61.9% (95% CI 38.4-81.9) on T2w fs for classification of liver fibrosis into low-stage and high-stage fibrosis. The AUC for TA on T1w was similar to MRE (0.82 [95% CI 0.59-0.95] vs. 0.92 [95% CI 0.71-0.99], p = 0.41), while the AUC for T2w fs was significantly lower compared to MRE (0.57 [95% CI 0.34-0.78] vs. 0.92 [95% CI 0.71-0.99], p = 0.008)., Conclusion: Our results suggest that liver fibrosis can be quantified with TA-derived parameters of T1w when combined with a ML algorithm with similar accuracy compared to MRE., Key Points: • Liver fibrosis can be categorized into low-stage fibrosis (0-2) and high-stage fibrosis (3-4) using texture analysis-derived parameters of T1-weighted images with a machine learning approach. • For the differentiation of low-stage fibrosis and high-stage fibrosis, the diagnostic accuracy of texture analysis on T1-weighted images combined with a machine learning algorithm is similar compared to MR elastography.
- Published
- 2020
- Full Text
- View/download PDF
38. Does quantitative assessment of arterial phase hyperenhancement and washout improve LI-RADS v2018-based classification of liver lesions?
- Author
-
Stocker D, Becker AS, Barth BK, Skawran S, Kaniewska M, Fischer MA, Donati O, and Reiner CS
- Subjects
- Adult, Aged, Algorithms, Area Under Curve, Evaluation Studies as Topic, Female, Humans, Liver diagnostic imaging, Male, Middle Aged, Observer Variation, Reproducibility of Results, Retrospective Studies, Sensitivity and Specificity, Carcinoma, Hepatocellular diagnostic imaging, Contrast Media, Image Enhancement methods, Liver Neoplasms diagnostic imaging, Magnetic Resonance Imaging methods, Radiology Information Systems statistics & numerical data
- Abstract
Objectives: To compare interreader agreement and diagnostic accuracy of LI-RADS v2018 categorization using quantitative versus qualitative MRI assessment of arterial phase hyperenhancement (APHE) and washout (WO) of focal liver lesions., Methods: Sixty patients (19 female; mean age, 56 years) at risk for HCC with 71 liver lesions (28 HCCs, 43 benign) who underwent contrast-enhanced MRI were included in this retrospective study. Four blinded radiologists independently assigned a qualitative LI-RADS score per lesion. Two other radiologists placed ROIs within the lesion, adjacent liver parenchyma, and paraspinal musculature on pre- and post-contrast MR images. The percentage of arterial enhancement and the liver-to-lesion contrast ratio were calculated for quantification of APHE and WO. Using these quantitative parameters, a quantitative LI-RADS score was assigned. Interreader agreement and AUCs were calculated., Results: Interreader agreement was similar for qualitative and quantitative LI-RADS (κ = 0.38 vs. 0.40-0.47) with a tendency towards improved agreement for quantitatively assessed APHE (κ = 0.65 vs. 0.81) and WO (κ = 0.53 vs. 0.78). Qualitative LI-RADS showed an AUC of 0.86, 0.94, 0.94, and 0.91 for readers 1, 2, 3, and 4, respectively. The quantitative LI-RADS score where APHE/WO/or both were replaced showed an AUC of 0.89/0.84/0.89, 0.95/0.92/0.92, 0.93/0.91/0.89, and 0.91/0.86/0.88 for readers 1, 2, 3, and 4, respectively. Sensitivity of LR-4/5 slightly increased, while specificity slightly decreased using quantitative APHE., Conclusion: Qualitative and quantitative LI-RADS showed similar performance. Quantitatively assessed APHE showed the potential to increase interreader agreement and sensitivity of HCC diagnosis, whereas quantitatively assessed WO had the opposite effect and needs to be redefined., Key Points: • Quantitative assessment of arterial phase hyperenhancement shows the potential to increase interreader agreement and sensitivity to diagnose hepatocellular carcinoma. • Adding quantitative measurements of major LI-RADS features does not improve accuracy over qualitative assessment alone according to the LI-RADS v2018 algorithm.
- Published
- 2020
- Full Text
- View/download PDF
39. Sequential Treatment of Metastatic Adenocarcinoma of the Pancreatic Duct with Liver Metastasis Following the NAPOLI-1 Study Protocol with nal-Irinotecan plus 5-FU in the Second Line.
- Author
-
Akhoundova Sanoyan D, Reiner CS, Papageorgiou P, and Siebenhüner AR
- Abstract
Pancreatic ductal adenocarcinoma (PDAC) is typically diagnosed at an advanced or metastatic stage, when curative surgery is not recommended. Therefore, the prognosis is poor for this dismal disease, with only 1-2% of the patients reaching the 5-year survival follow-up. Current advances in systemic treatment with gemcitabine regimens, specifically polychemotherapy with gemcitabine plus nab-paclitaxel or other multidrug regimens such as FOLFIRINOX in the first line, have improved disease control over time. This higher efficacy of systemic treatment enables metastatic PDAC patients to receive second-line treatment more often nowadays. Currently, there is only one regimen for second-line treatment approved by the EMA, FDA, and Swissmedic, based on the phase III NAPOLI-1 study. In this case report, we present an outstanding response to sequential treatment with gemcitabine plus nab-paclitaxel followed by second-line treatment with nal-irinotecan plus 5-fluorouracil., Competing Interests: The authors have no conflicts of interest to disclose., (Copyright © 2020 by S. Karger AG, Basel.)
- Published
- 2020
- Full Text
- View/download PDF
40. Diagnostic Accuracy of Multiparametric MRI versus 68 Ga-PSMA-11 PET/MRI for Extracapsular Extension and Seminal Vesicle Invasion in Patients with Prostate Cancer.
- Author
-
Muehlematter UJ, Burger IA, Becker AS, Schawkat K, Hötker AM, Reiner CS, Müller J, Rupp NJ, Rüschoff JH, Eberli D, and Donati OF
- Subjects
- Aged, Edetic Acid analogs & derivatives, Gallium Isotopes, Gallium Radioisotopes, Humans, Male, Middle Aged, Multiparametric Magnetic Resonance Imaging, Neoplasm Invasiveness pathology, Neoplasm Staging, Oligopeptides, Positron-Emission Tomography, Prostatectomy, Prostatic Neoplasms pathology, Prostatic Neoplasms surgery, Radiopharmaceuticals, Seminal Vesicles pathology, Sensitivity and Specificity, Multimodal Imaging, Neoplasm Invasiveness diagnostic imaging, Prostatic Neoplasms diagnostic imaging, Seminal Vesicles diagnostic imaging
- Abstract
Background Recent studies have reported the additive value of combined gallium 68 (
68 Ga)-labeled Glu-urea-Lys (Ahx)-HBED-CC ligand targeting the prostate-specific membrane antigen (PSMA) (hereafter called68 Ga-PSMA-11) PET/MRI for the detection and localization of primary prostate cancer compared with multiparametric MRI. Purpose To compare the diagnostic accuracy and interrater agreement of multiparametric MRI and68 Ga-PSMA-11 PET/MRI for the detection of extracapsular extension (ECE) and seminal vesicle infiltration (SVI) in patients with prostate cancer. Materials and Methods Retrospective analysis of 40 consecutive men who underwent multiparametric MRI and68 Ga-PSMA-11 PET/MRI within 6 months for suspected prostate cancer followed by radical prostatectomy between April 2016 and July 2018. Four readers blinded to clinical and histopathologic findings rated the probability of ECE and SVI at multiparametric MRI and PET/MRI by using a five-point Likert-type scale. The prostatectomy specimen served as the reference standard. Accuracy was assessed with a multireader multicase analysis and by calculating reader-average areas under the receiver operating characteristics curve (AUCs), sensitivity, and specificity for ordinal and dichotomized data in a region-specific and patient-specific approach. Interrater agreement was assessed with the Fleiss multirater κ. Results For multiparametric MRI versus PET/MRI in ECE detection, respectively, AUC, sensitivity, and specificity in the region-specific analysis were 0.67 and 0.75 ( P = .07), 28% (21 of 76) and 47% (36 of 76) ( P = .09), and 94% (529 of 564) and 90% (509 of 564) ( P = .007). For the patient-specific analysis, AUC, sensitivity, and specificity were 0.66 and 0.73 ( P = .19), 46% (22 of 48) and 69% (33 of 48) ( P = .04), and 75% (84 of 112) and 67% (75 of 112) ( P = .19), respectively. For multiparametric MRI versus PET/MRI in SVI detection, respectively, AUC, sensitivity, and specificity of the region-specific analysis were 0.66 and 0.74 ( P = .21), 35% (seven of 20) and 50% (10 of 20) ( P = .25), and 98% (295 of 300) and 94% (282 of 300) ( P < .001). For the patient-specific analysis, AUC, sensitivity, and specificity were 0.65 and 0.79 ( P = .25), 35% (seven of 20) and 55% (11 of 20) ( P = .20), and 98% (137 of 140) and 94% (131 of 140) ( P = .07), respectively. Interrater reliability for multiparametric MRI versus PET/MRI did not differ for ECE (κ, 0.46 vs 0.40; P = .24) and SVI (κ, 0.23 vs 0.33; P = .39). Conclusion Our results suggest that gallium 68 (68 Ga)-labeled Glu-urea-Lys (Ahx)-HBED-CC ligand targeting the prostate-specific membrane antigen (PSMA) (68 Ga-PSMA-11) PET/MRI and multiparametric MRI perform similarly for local staging of prostate cancer in patients with intermediate-to-high-risk prostate cancer. The increased sensitivity of68 Ga-PSMA-11 PET/MRI for the detection of extracapsular disease comes at the cost of a slightly reduced specificity. © RSNA, 2019.- Published
- 2019
- Full Text
- View/download PDF
41. Diffusion tensor imaging of the abdominal organs: Influence of oriented intravoxel flow compartments.
- Author
-
Phi van V, Reiner CS, Klarhoefer M, Ciritsis A, Eberhardt C, Wurnig MC, and Rossi C
- Subjects
- Adult, Anisotropy, Female, Humans, Image Processing, Computer-Assisted, Kidney diagnostic imaging, Liver diagnostic imaging, Male, Middle Aged, Motion, Signal Processing, Computer-Assisted, Young Adult, Abdomen diagnostic imaging, Diffusion Tensor Imaging
- Abstract
Water flow in partially oriented intravoxel compartments mimics an anisotropic fast-diffusion regime, which contributes to the signal attenuation in diffusion-weighted images. In the abdominal organs, this flow may reflect physiological fluid movements (eg, tubular urine flow in kidneys, or bile flow through the liver) and have a clinical relevance. This study investigated the influence of anisotropic intravoxel water flow on diffusion tensor imaging (DTI) of the abdominal organs. Diffusion-weighted images were acquired in five healthy volunteers using an EPI sequence with diffusion preparation (TR/TE: 1000 ms/71 ms; b-values: 0, 10, 20, 40, 70, 120, 250, 450, 700, 1000 s/mm
2 ; 12 noncollinear diffusion-encoding directions). DTI of liver and kidneys was performed assuming (i) monoexponential decay of the diffusion-weighted signal, and (ii) accounting for potential anisotropy of the fast-diffusion compartments using a tensorial generalization of the IVIM model. Additionally, potential dependency of the metrics of the tensors from the anatomical location was evaluated. Significant differences in the metrics of the diffusion tensor (DT) were found in both liver and kidneys when comparing the two models. In both organs, the trace and the fractional anisotropy of the DT were significantly higher in the monoexponential model than when accounting for perfusion. The comparison of areas of the liver proximal to the hilum with distal regions and of renal cortex with the medulla also proved a location dependency of the size of the fast-diffusion compartments. Pseudo-diffusion correction in DTI enables the assessment of the solid parenchyma regardless of the organ perfusion or other pseudo-diffusive fluid movements. This may have a clinical relevance in the assessment of parenchymal pathologies (eg, liver fibrosis). The fast pseudo-diffusion components present a detectable anisotropy, which may reflect the hepatic microcirculation or other sources of mesoscopic fluid movement in the abdominal organs., (© 2019 John Wiley & Sons, Ltd.)- Published
- 2019
- Full Text
- View/download PDF
42. Enterothorax After Hepatic Surgery: A Single-Center Experience.
- Author
-
Manzini G, Kuemmerli C, Reiner CS, Petrowsky H, and Gutschow CA
- Subjects
- Adult, Aged, Female, Hepatectomy methods, Humans, Liver Transplantation, Living Donors, Male, Middle Aged, Neoplasm Recurrence, Local surgery, Retrospective Studies, Hepatectomy adverse effects, Hernia, Abdominal etiology, Hernia, Diaphragmatic etiology, Liver Neoplasms surgery
- Abstract
Background: Enterothorax (ET) is a rare complication after hepatic surgery. The literature in this field is limited and mainly based on case reports. The aim of this study was to review our department's experience., Patients and Methods: We retrospectively analyzed 602 patients who underwent hepatic resection between November 2008 and December 2016. Major hepatic surgery (n = 321) was defined as right or extended right hepatectomy (n = 227), left or extended left hepatectomy (n = 63), trisegmentectomy (n = 13), and living donor liver transplantation (n = 18). ET cases were identified by analyzing clinical courses and radiological imaging., Results: ET was observed in five out of 602 patients (0.8%). All patients developed the complication after major hepatic surgery (five out of 321, 1.6%). ET exclusively occurred after right (n = 3) or extended right hepatectomy (n = 2). Median time to diagnosis was 22 months. Radiological imaging showed herniation of small (n = 2), large bowel (n = 2), or omental fat (n = 1) with a median diaphragmatic defect of 3.9 cm. Two patients presented with acute incarceration and underwent emergency surgery, one patient reported recurrent pain and underwent elective repair, and two patients refused surgery. Follow-up imaging in two operated patients showed no recurrence of ET after 36 and 8 months., Conclusions: Patients after right hepatectomy have a substantial risk of ET. Acute right upper quadrant pain and/or dyspnea after hepatectomy should be investigated with adequate radiological imaging. Elective surgical repair of ET is recommended to avoid emergency surgery in case of incarceration.
- Published
- 2019
- Full Text
- View/download PDF
43. How to define pathologic pelvic floor descent in MR defecography during defecation?
- Author
-
Schawkat K, Heinrich H, Parker HL, Barth BK, Mathew RP, Weishaupt D, Fox M, and Reiner CS
- Subjects
- Adult, Female, Humans, Male, Middle Aged, Pelvic Floor diagnostic imaging, Pelvic Floor physiopathology, Prospective Studies, Defecation physiology, Defecography methods, Magnetic Resonance Imaging methods, Pelvic Floor Disorders diagnostic imaging, Pelvic Floor Disorders physiopathology
- Abstract
Objectives: To assess the extents of pelvic floor descent both during the maximal straining phase and the defecation phase in healthy volunteers and in patients with pelvic floor disorders, studied with MR defecography (MRD), and to define specific threshold values for pelvic floor descent during the defecation phase., Material and Methods: Twenty-two patients (mean age 51 ± 19.4) with obstructed defecation and 20 healthy volunteers (mean age 33.4 ± 11.5) underwent 3.0T MRD in supine position using midsagittal T2-weighted images. Two radiologists performed measurements in reference to PCL-lines in straining and during defecation. In order to identify cutoff values of pelvic floor measurements for diagnosis of pathologic pelvic floor descent [anterior, middle, and posterior compartments (AC, MC, PC)], receiver-operating characteristic (ROC) curves were plotted., Results: Pelvic floor descent of all three compartments was significantly larger during defecation than at straining in patients and healthy volunteers (p < 0.002). When grading pelvic floor descent in the straining phase, only two healthy volunteers showed moderate PC descent (10%), which is considered pathologic. However, when applying the grading system during defecation, PC descent was overestimated with 50% of the healthy volunteers (10 of 20) showing moderate PC descent. The AUC for PC measurements during defecation was 0.77 (p = 0.003) and suggests a cutoff value of 45 mm below the PCL to identify patients with pathologic PC descent. With the adapted cutoff, only 15% of healthy volunteers show pathologic PC descent during defecation., Conclusion: MRD measurements during straining and defecation can be used to differentiate patients with pelvic floor dysfunction from healthy volunteers. However, different cutoff values should be used during straining and during defecation to define normal or pathologic PC descent.
- Published
- 2018
- Full Text
- View/download PDF
44. Dynamic MRI of the pelvic floor: comparison of performance in supine vs left lateral body position.
- Author
-
Schawkat K, Pfister B, Parker H, Heinrich H, Barth BK, Weishaupt D, Fox M, and Reiner CS
- Subjects
- Adult, Defecation, Defecography, Female, Humans, Male, Patient Satisfaction, Prospective Studies, Supine Position, Constipation diagnostic imaging, Magnetic Resonance Imaging methods, Pelvic Floor diagnostic imaging, Posture
- Abstract
Objective:: To investigate the performance of MR-defecography (MRD) in lateral body position as an alternative to supine position., Methods:: 22 consecutive patients (16 females; mean age 51 ± 19.4) with obstructed defecation and 20 healthy volunteers (11 females; mean age 33.4 ± 11.5) underwent MRD in a closed-configuration 3T-MRI in supine and lateral position. MRD included T
2 weighted images at rest and during defecation after filling the rectum with 250 ml water-based gel. Measurements were performed in reference to the pubococcygeal line and grade of evacuation was assessed. Image quality (IQ) was rated on a 5-point-scale (5 = excellent)., Results:: In patients grades of middle and posterior compartment descent were similar in both body positions (p > 0.05). Grades of anterior compartment descent were significantly higher in lateral position (21/22 vs 17/22 patients with normal or small descent, p < 0.034). In volunteers grades of descent were similar for all compartments in supine and lateral position (p > 0.05). When attempting to defecate in supine position 6/22 (27%) patients showed no evacuation, while in lateral position only 3/22 (14%) were not able to evacuate. IQ in patients was equal at rest (4.4 ± 0.5 and 4.7 ± 0.6, p > 0.05) and slightly better in supine compared to the lateral position during defecation (4.5 ± 0.4 vs 3.9 ± 0.9, p < 0.017). IQ in volunteers was equal in supine and lateral position (p > 0.05)., Conclusion:: In lateral position, more patients were able to evacuate with similar grades of pelvic floor descent compared to supine position. MRD in lateral position may be a valuable alternative for patients unable to defecate in supine position., Advances in Knowledge:: In lateral position, more patients were able to evacuate during MRD. MRD in lateral position may be an alternative for patients unable to defecate in supine position.- Published
- 2018
- Full Text
- View/download PDF
45. Preoperative Evaluation of Pancreatic Fibrosis and Lipomatosis: Correlation of Magnetic Resonance Findings With Histology Using Magnetization Transfer Imaging and Multigradient Echo Magnetic Resonance Imaging.
- Author
-
Schawkat K, Eshmuminov D, Lenggenhager D, Endhardt K, Vrugt B, Boss A, Petrowsky H, Clavien PA, and Reiner CS
- Subjects
- Adult, Aged, Aged, 80 and over, Echo-Planar Imaging methods, Female, Fibrosis, Humans, Image Processing, Computer-Assisted methods, Lipomatosis complications, Male, Middle Aged, Pancreas diagnostic imaging, Pancreas pathology, Pancreas ultrastructure, Pancreatic Diseases complications, Pancreatic Neoplasms surgery, Lipomatosis diagnostic imaging, Magnetic Resonance Imaging methods, Pancreatic Diseases diagnostic imaging, Pancreatic Diseases pathology, Pancreatic Neoplasms complications, Preoperative Care methods
- Abstract
Objectives: The purpose of this study was to evaluate the diagnostic performance of magnetization transfer (MT) imaging and multigradient echo magnetic resonance imaging (MRI) to quantify pancreatic fibrosis and lipomatosis in patients before pancreatoduodenectomy for postoperative risk stratification with histopathology as the reference standard., Materials and Methods: Twenty-four patients (age, 68 ± 8 years, 16 males) prospectively underwent quantitative MT imaging using a 2-dimensional gradient echo sequence with and without MT prepulse and multigradient echo imaging on a 3 T MRI 1 day before pancreatoduodenectomy due to adenocarcinoma of the pancreatic head region (n = 20), neuroendocrine tumor (n = 3), or intraductal papillary mucinous neoplasm (n = 1). Magnetization transfer ratio (MTR) and proton density fat fraction (PDFF) were measured in pancreatic tail (PT) and at the resection margin (RM). Histopathologically, pancreatic fibrosis was graded as mild, moderate, or severe (F1-F3), lipomatosis was graded as 0% to 10%, 11% to 30%, and greater than 30% fat deposition (L1-L3). In addition, MTR and histopathologic fibrosis was assessed in pancreatic adenocarcinoma. Mann-Whitney U test and Spearman correlation were used., Results: Patients with advanced pancreatic fibrosis (F3) showed a significantly higher MTR compared with the F1 group at the RM and PT (38 ± 4 vs 32.3 ± 1.6, P = 0.018 and 39.7 ± 5.5 vs 31.2 ± 1.7, P = 0.001). Spearman correlation coefficient of MTR and fibrosis grade was r = 0.532 (P = 0.011) and 0.554 (P = 0.008), respectively. Pancreatic parenchyma with advanced fat deposition (L2-L3) showed significantly higher PDFF compared with lipomatosis grade L1 (RM: P = 0.002 and PT: P = 0.001). Proton density fat fraction of pancreatic parenchyma exhibited a moderate and significant correlation with histopathologic lipomatosis grade (RM: r = 0.668 and PT: r = 0.707, P < 0.001). Magnetization transfer ratio was significantly higher in pancreatic adenocarcinoma compared with pancreatic parenchyma (44 ± 5.5 vs 36.0 ± 4.4 and 37.4 ± 5.4, P = 0.004)., Conclusions: Multiparametric MRI of the pancreas including MTR and PDFF maps may provide quantitative and noninvasive information on pancreatic fibrosis and lipomatosis before surgery.
- Published
- 2018
- Full Text
- View/download PDF
46. Accuracy of Automated Liver Contouring, Fat Fraction, and R2* Measurement on Gradient Multiecho Magnetic Resonance Images.
- Author
-
Stocker D, Bashir MR, Kannengiesser SAR, and Reiner CS
- Subjects
- Adipose Tissue diagnostic imaging, Adipose Tissue pathology, Adolescent, Adult, Aged, Aged, 80 and over, Fatty Liver pathology, Female, Humans, Liver diagnostic imaging, Liver pathology, Male, Middle Aged, Reproducibility of Results, Retrospective Studies, Young Adult, Fatty Liver diagnostic imaging, Image Processing, Computer-Assisted methods, Magnetic Resonance Imaging methods
- Abstract
Objective: This study aimed to evaluate the performance of an automated workflow of volumetric liver proton density fat fraction (PDFFvol) and R2* quantification with automated inline liver volume (LV) segmentation., Methods: Dual-echo and multiecho Dixon magnetic resonance images were evaluated in 74 consecutive patients (group A, PDFF < 10%; B, PDFF ≥ 10%; C, R2* ≥ 100 s; D, post-hemihepatectomy). The values of PDFFvol and R2*vol measurements across the LV were generated on multiecho images in an automated fashion based on inline liver segmentation on dual-echo images. Similar measurements were performed manually., Results: Using the inline algorithm, the mis-segmented LV was highest in group D (80%). There were no significant differences between automated and manual measurements of PDFFvol. Automated R2*vol was significantly lower than manual R2*vol in group A (P = 0.004)., Conclusions: Inline LV segmentation performed well in patients without and with hepatic steatosis. In cases with iron overload and post-hemihepatectomy, extrahepatic areas were erroneously included to a greater extent, with a tendency toward overestimation of PDFFvol.
- Published
- 2018
- Full Text
- View/download PDF
47. Performance of an Automated Versus a Manual Whole-Body Magnetic Resonance Imaging Workflow.
- Author
-
Stocker D, Finkenstaedt T, Kuehn B, Nanz D, Klarhoefer M, Guggenberger R, Andreisek G, Kiefer B, and Reiner CS
- Subjects
- Adult, Aged, Female, Humans, Male, Middle Aged, Prospective Studies, Reproducibility of Results, Magnetic Resonance Imaging methods, Whole Body Imaging methods, Workflow
- Abstract
Objectives: The aim of this study was to evaluate the performance of an automated workflow for whole-body magnetic resonance imaging (WB-MRI), which reduces user interaction compared with the manual WB-MRI workflow., Materials and Methods: This prospective study was approved by the local ethics committee. Twenty patients underwent WB-MRI for myopathy evaluation on a 3 T MRI scanner. Ten patients (7 women; age, 52 ± 13 years; body weight, 69.9 ± 13.3 kg; height, 173 ± 9.3 cm; body mass index, 23.2 ± 3.0) were examined with a prototypical automated WB-MRI workflow, which automatically segments the whole body, and 10 patients (6 women; age, 35.9 ± 12.4 years; body weight, 72 ± 21 kg; height, 169.2 ± 10.4 cm; body mass index, 24.9 ± 5.6) with a manual scan. Overall image quality (IQ; 5-point scale: 5, excellent; 1, poor) and coverage of the study volume were assessed by 2 readers for each sequence (coronal T2-weighted turbo inversion recovery magnitude [TIRM] and axial contrast-enhanced T1-weighted [ce-T1w] gradient dual-echo sequence). Interreader agreement was evaluated with intraclass correlation coefficients. Examination time, number of user interactions, and MR technicians' acceptance rating (1, highest; 10, lowest) was compared between both groups., Results: Total examination time was significantly shorter for automated WB-MRI workflow versus manual WB-MRI workflow (30.0 ± 4.2 vs 41.5 ± 3.4 minutes, P < 0.0001) with significantly shorter planning time (2.5 ± 0.8 vs 14.0 ± 7.0 minutes, P < 0.0001). Planning took 8% of the total examination time with automated versus 34% with manual WB-MRI workflow (P < 0.0001). The number of user interactions with automated WB-MRI workflow was significantly lower compared with manual WB-MRI workflow (10.2 ± 4.4 vs 48.2 ± 17.2, P < 0.0001). Planning efforts were rated significantly lower by the MR technicians for the automated WB-MRI workflow than for the manual WB-MRI workflow (2.20 ± 0.92 vs 4.80 ± 2.39, respectively; P = 0.005). Overall IQ was similar between automated and manual WB-MRI workflow (TIRM: 4.00 ± 0.94 vs 3.45 ± 1.19, P = 0.264; ce-T1w: 4.20 ± 0.88 vs 4.55 ± .55, P = 0.423). Interreader agreement for overall IQ was excellent for TIRM and ce-T1w with an intraclass correlation coefficient of 0.95 (95% confidence interval, 0.86-0.98) and 0.88 (95% confidence interval, 0.70-0.95). Incomplete coverage of the thoracic compartment in the ce-T1w sequence occurred more often in the automated WB-MRI workflow (P = 0.008) for reader 2. No other significant differences in the study volume coverage were found., Conclusions: In conclusion, the automated WB-MRI scanner workflow showed a significant reduction of the examination time and the user interaction compared with the manual WB-MRI workflow. Image quality and the coverage of the study volume were comparable in both groups.
- Published
- 2018
- Full Text
- View/download PDF
48. Liver Allograft Failure After Nivolumab Treatment-A Case Report With Systematic Literature Research.
- Author
-
Gassmann D, Weiler S, Mertens JC, Reiner CS, Vrugt B, Nägeli M, Mangana J, Müllhaupt B, Jenni F, and Misselwitz B
- Abstract
Background: Orthotopic liver transplantation (OLT) is a potential curative treatment in patients with hepatocellular carcinoma (HCC); however, treatment options for recurrent HCC after OLT are limited. Immune checkpoint inhibitors, such as nivolumab, an inhibitor of programmed cell death protein 1, have been successfully used for metastatic HCC but data on safety of nivolumab following solid organ transplantation are limited., Methods: We report a 53-year-old woman with HCC who was treated with OLT. After 2 years, HCC recurred. Initial treatment with sorafenib was discontinued due to side effects and disease progression. Progressive HCC in the lung and lymph nodes was subsequently treated with nivolumab. One week after the first nivolumab dose, rapid progressive liver dysfunction was noted. Liver biopsy revealed severe cellular graft rejection prompting treatment with intravenous steroids and tacrolimus. Liver function continued to decline, leading to severe coagulopathy. The patient succumbed to intracranial hemorrhage., Results: A systematic PubMed search revealed 29 cases treated with a checkpoint inhibitor following solid organ transplantation. Loss of graft was described in 4 (36%) of 11 cases with OLT and in 7 (54%) of 13 cases after kidney transplantation. However, cases with favorable outcome were also described. Eighteen cases with adverse events were identified upon searching the World Health Organization database VigiBase, including 2 cases with fatal outcome in liver transplant recipients due to graft loss., Conclusion: Experience with checkpoint inhibitors in solid organ transplant recipients is limited. Published cases so far suggest severe risks for graft loss as high as 36% to 54%.
- Published
- 2018
- Full Text
- View/download PDF
49. WITHDRAWN: Evaluation of multifunctional imaging parameters in gastro-oesophageal cancer using F-18-FDG-PET/CT with integrated perfusion CT.
- Author
-
Sah BR, Leissing CA, Delso G, Ter Voert EE, Krieg S, Leibl S, Schneider PM, Reiner CS, Hüllner MW, and Veit-Haibach P
- Abstract
Ahead of Print article withdrawn by publisher.
- Published
- 2018
- Full Text
- View/download PDF
50. MRI and PET-CT Failed to Differentiate Between Hepatic Malignancy and Brucelloma.
- Author
-
Schreiber PW, Schmid A, Fagagnini S, Kröger A, Vrugt B, Reiner CS, Boggian K, Schiesser M, Müllhaupt B, and Günthard HF
- Abstract
Brucellosis is a common, worldwide zoonosis. Clinical presentation is protean and often goes unrecognized. Hepatic brucelloma is a rare local complication of chronic brucellosis. We report a case in which magnetic resonance imaging and positron emission tomography imaging prompted suspicion of a hepatic malignancy. Diagnosis was ultimately made by serology and polymerase chain reaction of resected liver tissue.
- Published
- 2018
- Full Text
- View/download PDF
Catalog
Discovery Service for Jio Institute Digital Library
For full access to our library's resources, please sign in.