374 results on '"Resistência de união"'
Search Results
2. INFLUÊNCIA DA ÁGUA OZONIZADA PREVIAMENTE AO USO DE DOIS SISTEMAS ADESIVOS UNIVERSAIS NA RESISTÊNCIA DE UNIÃO DAS RESINAS COMPOSTAS BULK FILL FLOW: ESTUDO IN VITRO.
- Author
-
Caroliny Detogni, Anna, Pereira Silva, Marina, Coelho Sinhoreti, Mário Alexandre, Katuhide Ueda, Julio, and Camilotti, Veridiana
- Subjects
CONTROLLED low-strength materials (Cement) ,SURFACE cleaning ,ADHESIVES ,INCISORS ,WATER use - Abstract
Copyright of Revista Foco (Interdisciplinary Studies Journal) is the property of Revista Foco and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
- Published
- 2023
- Full Text
- View/download PDF
3. Effect of applying Er:YAG laser on glass fiber posts with two different designs on the surface roughness and the pull-out bond strength: An in vitro study.
- Author
-
ABOHAJAR, Salam Ahmad
- Subjects
BOND strengths ,GLASS fibers ,SURFACE roughness ,FIBER lasers ,IN vitro studies - Abstract
Copyright of Dental Press Endodontics is the property of Dental Press International and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
- Published
- 2023
- Full Text
- View/download PDF
4. Efeito da concentração do ácido hidrofluorídrico e do envelhecimento na resistência de união da cerâmica vítrea ao cimento resinoso.
- Author
-
CORRER-SOBRINHO, Lourenço, CORRER, Américo Bortolazzo, CONSANI, Rafael Leonardo Xedieck, FERRAZ, Analia Gabriella Borges, BORGES, Gilberto Antonio, and COSTA, Ana Rosa
- Abstract
Copyright of Journal of Clinical Dentistry & Research is the property of Dental Press International and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
- Published
- 2023
- Full Text
- View/download PDF
5. Do irrigation solutions used during root canal instrumentation influence the adhesion of glass fiber posts? A systematic review.
- Author
-
REYS, Irma Gonçalves, GUIMARÃES, Ludmila Silva, TERRA, Lorran Soares Duarte, CAJAZEIRA, Marlus Roberto Rodrigues, ANTUNES, Lívia Azeredo Alves, and ANTUNES, Leonardo Santos
- Subjects
BOND strengths ,ADHESIVE cements ,ROOT canal treatment ,GLASS fibers ,SODIUM hypochlorite ,ENDODONTICS - Abstract
Copyright of Brazilian Dental Science is the property of Brazilian Dental Science Journal-ICT-UNESP and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
- Published
- 2023
- Full Text
- View/download PDF
6. Effect of time and dental substrate on the bond strength of a universal adhesive system: in vitro study.
- Author
-
CARDOSO, Poliana Maria de Faveri, VANOLLI, Rafael da Silva, RIBEIRO, Fernanda Rafaela, MENDONÇA, Marcio José, and CAMILOTTI, Veridiana
- Subjects
BOND strengths ,DENTAL bonding ,DENTAL crowns ,ADHESIVES ,DENTAL materials - Abstract
Copyright of Universidade Estadual Paulista. Revista de Odontologia is the property of Universidade Estadual Paulista. Revista de Odontologia and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
- Published
- 2023
- Full Text
- View/download PDF
7. EFEITOS DE TRATAMENTOS DE SUPERFÍCIE NA RESISTÊNCIA DE UNIÃO DE ZIRCÔNIA TETRAGONAL PARCIALMENTE ESTABILIZADA POR ÍTRIA: CERCON E PRETTAU ANTERIOR.
- Author
-
CALABREZ-FILHO, Saturnino, BORGES, Gilberto Antônio, CALABREZ, Amanda Nascimento, Silveira MIRANZI, Benito André, CALABREZ, Giovanna Nascimento, and BORGES, Luis Henrique
- Abstract
Copyright of Journal of Clinical Dentistry & Research is the property of Dental Press International and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
- Published
- 2021
- Full Text
- View/download PDF
8. EFFECTIVENESS OF GRAPE SEED EXTRACT-BASED INTRACANAL DRESSINGS AGAINST Enterococcus Faecalis AND ITS INFLUENCE ON DENTIN MICROHARDNESS AND BOND STRENGTH OF FILLING MATERIAL.
- Author
-
Albino SOUZA, Matheus, de Lima DALLA LANA, Daniel, PLETSCH, Amália, Scartazzini PALHANO, Huriel, BERVIAN, Juliane, de CARLI, João Paulo, and CECCHIN, Doglas
- Subjects
MICROHARDNESS ,BOND strengths ,GRAPE seeds ,ANTI-infective agents ,CHLORHEXIDINE - Abstract
Copyright of Bioscience Journal is the property of Bioscience Journal and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
- Published
- 2020
- Full Text
- View/download PDF
9. Resistência de união à microtração de sistemas adesivos 'condiciona-e-lava' de dois passos: efeito de diferentes tratamentos da superfície dentinária condicionada
- Author
-
Tamíris Pereira da Costa NEVES, Thais Piragine LEANDRIN, Mateus Rodrigues TONETTO, Marcelo Ferrarezi ANDRADE, and Edson Alves de CAMPOS
- Subjects
Adesivos dentinários ,dentina ,clorexidina ,etanol ,resistência de união ,Medicine ,Dentistry ,RK1-715 - Abstract
Resumo Introdução A evolução dos sistemas adesivos permitiu que os fabricantes desenvolvessem materiais com técnicas cada vez mais simplificadas, porém que, ainda assim, promovessem adequados valores de resistência de união imediata. Sugere-se que alguns tratamentos da superfície dentinária podem favorecer esse processo de adesão. Objetivo Avaliar os efeitos de diferentes tratamentos, em superfície dentinária plana condicionada, sobre a resistência de união à microtração de sistemas adesivos do tipo “condiciona-e-lava” de dois passos. Material e método Noventa e seis terceiros molares humanos foram divididos em 12 grupos (n=8), aleatoriamente, de acordo com o sistema adesivo utilizado (GI: Adper Single Bond 2 - 3M ESPE; GII: Prime & Bond 2.1 - Dentsply; GIII: Excite - Ivoclar Vivadent) e o tipo de tratamento do substrato dentinário condicionado (a: água; b: clorexidina + água; c: etanol; d: clorexidina + etanol). Todos os dentes foram restaurados com resina Charisma na cor A2 (Heraeus - Kulzer, Germany) e submetidos a ensaio mecânico de microtração (EMIC DL-2000). O teste estatístico realizado foi ANOVA a um fator, completado com teste de Tukey. Resultado Os grupos GIIc, GIIIc e GIId apresentaram aumento significativo estatisticamente na resistência de união à microtração imediata. Conclusão Os diferentes tratamentos da dentina condicionada não afetaram de maneira negativa a resistência de união para todos os sistemas adesivos testados e a utilização da técnica com etanol, associado ou não à clorexidina, parece ser uma interessante abordagem quando associada a sistemas adesivos “condiciona-e-lava” de dois passos.
- Published
- 2017
- Full Text
- View/download PDF
10. UNIÃO À RESINA COMPOSTA, DENTINA E INTERFACE COMPÓSITO-DENTINA NO REPARO DE RESTAURAÇÕES.
- Author
-
Manso, Isabella S., Valente, Lisia L., Münchow, Eliseu A., Isolan, Cristina P., Lima, Fábio G., and Moraes, Rafael R.
- Abstract
Copyright of Journal of Clinical Dentistry & Research is the property of Dental Press International and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
- Published
- 2019
- Full Text
- View/download PDF
11. Influence of calcium hypochlorite on adhesion of resinous materials to the pulpar chamber and root canal
- Author
-
Pauletto, Guilherme, Bier, Carlos Alexandre Souza, Pappen, Fernanda Geraldo, and Rosa, Ricardo Abreu da
- Subjects
Bond strength ,Sodium hypochlorite ,Hipoclorito de cálcio ,Resina composta ,Calcium hypochlorite ,CIENCIAS DA SAUDE::ODONTOLOGIA [CNPQ] ,Cimento resinoso ,Resin composite ,Resin cement ,Hipoclorito de sódio ,Resistência de união - Abstract
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES This dissertation is composed of two studies. The first study aimed to compare the effect of sodium hypochlorite (NaOCl) and calcium hypochlorite [Ca(OCl)2], followers or not of the use of sodium thiosulfate (Na2S2O3), on the bond strength of a resin composite restoration to pulp chamber dentin. For this, the pulp chamber of fifty human molars were randomly distributed into 5 groups (n=10) according to the immersion protocol: 2.5% NaOCl; 2.5% NaOCl + 5% Na2S2O3; 2.5% Ca(OCl)2; 2.5% Ca(OCl)2 + 5% Na2S2O3; and 0.9% sodium chloride (NaCl), (control). Subsequently, the samples were restored with resin composite. Three sticks were obtained from the pulp chamber and subjected to the microtensile test. Scanning electron microscopy (SEM) and energy dispersive x-ray spectroscopy (EDS) analyzes were obtained from the pulp chamber roof (n=8) for mineral quantification. As a result, compared to control, the 2.5% NaOCl group was associated with the lowest values of bond strength and the 2.5% Ca(OCl)2 group presented similar bond strength. The 5% Na2S2O3 was able to increase the bond strength after the use of 2.5% NaOCl, but not after 2.5% Ca(OCl)2. The group treated only with 2.5% Ca(OCl)2 had a higher Ca/P ratio on the dentin surface. The second study aimed to evaluate the bond strength in the different dentinal thirds of the post space and adaptation failures (gaps) at the cement/dentin interface, resulting from the interaction between a dual-curing resin cement and a substrate irrigated with different concentrations of NaOCl or Ca(OCl)2. For this, after intraradicular preparation for posts in 50 endodontically treated premolars, the specimens were divided into 5 groups (n=10) according to the irrigant: 0.9% NaCl (control); 2.5% NaOCl; 5.25% NaOCl; 2.5% Ca(OCl)2; and 5.25% Ca(OCl)2. After irrigation, the posts were cemented with a dual-curing resin cement. One slice from each third were submitted to the push-out test. A additional slice of the middle third was submitted to confocal images for analysis of adaptation failures (gaps). As a result, the group treated with 5.25% NaOCl showed lower bond strength values than the control group. Bond strength decreased from coronal to apical in the post space. The 5.25% NaOCl generated more cohesive failures compared to the control group and 2.5% Ca(OCl)2. The groups treated with NaOCl had the highest percentages of gaps in relation to the control. Regardless of concentration, Ca(OCl)2 had no influence on the bond strength, and on the occurrence of gaps. In general conclusion, in both studies, Ca(OCl)2 did not affect bond strength in adhesive procedures. In addition, it was not affected by Na2S2O3, increased the Ca/P ratio on the dentin surface and did not interfere with the presence of gaps in the post space. A presente dissertação é composta por dois estudos. O objetivo do primeiro estudo foi comparar o efeito do hipoclorito de sódio (NaOCl) e do hipoclorito de cálcio [Ca(OCl)2], seguidos ou não do uso do tiossulfato de sódio (Na2S2O3), na resistência de união de uma restauração de resina composta à dentina da câmara pulpar. Para isso, a câmara pulpar de cinquenta molares humanos foram distribuídas aleatoriamente em 5 grupos (n=10) conforme o protocolo de imersão: NaOCl 2.5%; NaOCl 2.5% + Na2S2O3 5%; Ca(OCl)2 2.5%; Ca(OCl)2 2.5% + Na2S2O3 5%; e cloreto de sódio 0.9% (NaCl), (controle). Posteriormente as amostras foram restauradas com resina composta. Três palitos foram obtidos da câmara pulpar e submetidos ao teste de microtração. Análises em microscopia eletrônica de varredura (MEV) e espectroscopia de energia dispersiva (EDS) foram obtidas do teto da câmara pulpar (n=8) para quantificação mineral. Como resultados, comparado ao controle, o grupo NaOCl 2,5% foi associado aos menores valores de resistência de união e o grupo Ca(OCl)2 2,5% apresentou resistência de união semelhante. O Na2S2O3 5% foi capaz de aumentar a resistência de união após o uso de NaOCl 2,5%, mas não após o Ca(OCl)2 2,5%. O grupo tratado apenas com Ca(OCl)2 2,5% apresentou maior razão Ca/P na superfície dentinária. O segundo estudo teve como objetivo avaliar a resistência de união nos diferentes terços dentinários do espaço protético e falhas de adaptação (gaps) na interface cimento/dentina, resultantes da interação entre um cimento resinoso dual e um substrato irrigado com diferentes concentrações de NaOCl ou Ca(OCl)2. Para isso, após o preparo intrarradicular para pinos de fibra em 50 pré-molares tratados endodonticamente, os espécimes foram divididos em 5 grupos (n=10) de acordo com o protocolo de irrigação: NaCl 0,9% (controle); NaOCl 2,5%; NaOCl 5,25%; Ca(OCl)2 2,5%; e Ca(OCl)2 5,25%. Após irrigação, os pinos foram cimentados com um cimento resinoso dual. Três fatias, correspondentes aos terços, foram obtidas do espaço protético e submetidas ao teste de push-out. Uma fatia adicional do terço médio foi submetida a imagens confocais para análise de gaps. Como resultado, o grupo tratado com NaOCl 5,25% apresentou valores de resistência de união menores que o grupo controle. A resistência de união diminuiu de coronal para apical no espaço protético. O NaOCl 5,25% gerou mais falhas coesivas em comparação ao grupo controle e ao Ca(OCl)2 2,5%. Os grupos tratados com NaOCl apresentaram os maiores percentuais de gaps em relação ao controle. Independente da concentração, o Ca(OCl)2 não teve influência na resistência de união e na ocorrência de gaps. Como conclusão geral, nos dois estudos o Ca(OCl)2 não afetou a resistência de união em procedimentos adesivos. Além disso, não sofreu efeito do Na2S2O3, aumentou a razão Ca/P na superfície dentinária e não interferiu na presença de gaps no espaço protético.
- Published
- 2023
12. Efeito da vibração sônica na película de cimento para união de pinos de fibra de vidro à dentina radicular – avaliação por MEV.
- Author
-
Neves Chaves, Thais Mariana, Mushashe, Amanda M., Jatahy Ferreira do Amaral, Rodrigo Otavio, Castiglia Gonzaga, Carla, and Eduardo Rezende, Carlos E.
- Subjects
FIBER cement ,SCANNING electron microscopy ,ROOT canal treatment ,DENTIN ,INFORMATION storage & retrieval systems - Abstract
Copyright of RSBO: Revista Sul-Brasileira de Odontologia is the property of UNIVILLE and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
- Published
- 2019
- Full Text
- View/download PDF
13. Avaliação da resistência de união de restaurações de resina composta com diferentes sistemas adesivos, em dois tempos de armazenamento
- Author
-
Fernando Zurlo Dellazzana, Fabio Herrmann Coelho-de-Souza, and Celso Afonso Klein-Júnior
- Subjects
adesivos dentinários ,resinas compostas ,resistência de união ,Dentistry ,RK1-715 - Abstract
A degradação hidrolítica dos adesivos dentinários pode influenciar a resistência de união das restaurações de resina composta ao longo do tempo. O objetivo deste trabalho é avaliar a influência do tempo de armazenamento associada à termociclagem e do tipo de adesivo dentinário empregado sobre a resistência de união de restaurações de resina composta. Foram utilizados 20 molares hígidos, os quais foram divididos em 2 tempos de avaliação (24 horas e 6 meses + termociclagem). Cada dente teve a dentina relativa à superfície oclusal exposta, a qual recebeu 3 corpos de prova de resina Flow com os sistemas adesivos: Scotchbond multiuso (3M/ESPE - Grupo 1), ClearFil SE Bond (Kuraray - Grupo 2) e Adper Single Bond (3M/ESPE - Grupo 3). Após o teste de microcisalhamento, os dados foram analisados estatisticamente pelos testes ANOVA, Tukey e t-student (?=0,05). Os resultados mostraram que os adesivos Scotchbond multiuso, ClearFil SE Bond e Single Bond não apresentaram diferenças na resistência de união em 24 horas de armazenamento. Após 6 meses, o adesivo ClearFil SE Bond obteve resistência superior ao Scotchbond multiuso. O adesivo Scotchbond multiuso sofreu redução na resistência de união após 6 meses de armazenamento. Os adesivos ClearFil SE Bond e Single Bond não sofreram influência do tempo de armazenamento e da termociclagem.
- Published
- 2008
- Full Text
- View/download PDF
14. Resistência de união entre dentes artificiais e resinas acrílicas para base protética Shear bond strength between artificial acrylic resin teeth and denture base resins
- Author
-
Ana C. Pero, Juliê Marra, Cilene A. Polatto, Débora B. Barbosa, and Marco A. Compagnoni
- Subjects
Resina acrílica ,resistência de união ,dente artificial ,microondas ,Acrylic resin ,shear bond strength ,artificial tooth ,microwaves ,Chemical technology ,TP1-1185 - Abstract
A resistência de união entre dente artificial e resina acrílica para base protética foi avaliada sob a influência de duas marcas comerciais de dentes artificiais (Biotone e Trilux) e de três resinas acrílicas, sendo duas polimerizadas convencionalmente em banho de água (QC-20 e Lucitone 550) e uma resina polimerizada por meio da energia de microondas (Acron-MC). As avaliações foram realizadas por meio de um ensaio mecânico de cisalhamento através da aplicação de uma carga perpendicular à interface dente-resina. Os resultados indicaram que, para a mesma resina, a resistência foi semelhante, independentemente do tipo de dente utilizado. Para os dois tipos de dente avaliados, as resinas Acron MC e Lucitone 550 apresentaram valores de resistência de união entre dente artificial e resina acrílica estatisticamente semelhantes e superiores em relação à resina QC-20.Shear bond strength between artificial acrylic resin teeth and denture base resin was evaluated under the influence of two brands of artificial teeth (Biotone and Trilux) and three denture base resins. Two of these resins were conventionally polymerized in water bath (QC-20 and Lucitone 550), while the other was a microwave-polymerized resin (Acron-MC). The evaluations were done by means of a shear bond strength test with application of a perpendicular load to the interface tooth-resin. The results showed that, for the same denture resin, the strength was similar regardless of the tooth brand. Also, for the two evaluated brands of tooth, the resins Acron MC and Lucitone 550 presented similar shear bond strengths, which were statistically higher than for resin QC-20.
- Published
- 2007
- Full Text
- View/download PDF
15. Protótipo para medir in vivo a força de descolagem de braquetes ortodônticos.
- Author
-
Lagni Tonus, Jéssika, Borguetti Manfroi, Fernanda, Antonio Borges, Gilberto, Correa Grigolo, Eduardo, Helegda, Sérgio, and Maria Spohr, Ana
- Abstract
Copyright of Dental Press Journal of Orthodontics is the property of Dental Press International and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
- Published
- 2017
- Full Text
- View/download PDF
16. Effect of tooth age on bond strength to dentin Efeito da idade na resistência de união
- Author
-
Marcelo Giannini, Patrícia Chaves, and Marcelo Tavares de Oliveira
- Subjects
Dentina ,Idade ,Sistema adesivo ,Resistência de união ,Dentin ,Tooth age ,Adhesive system ,Bond strength ,Dentistry ,RK1-715 - Abstract
This in vitro study evaluated the effect of tooth age on the tensile bond strength of Prime & Bond NT adhesive system to dentin. Human third molars from the five age groups were analyzed: A- 17 to 20yrs, B- 21 to 30yrs, C- 31 to 40yrs, D- 41 to 50yrs and E- 51 to 63yrs. The occlusal enamel was removed using a diamond saw under water cooling and the dentin surface was wet-ground with 600-grit SiC paper to obtain flat surfaces. The adhesive system was applied according to the manufacturer's instructions and a 6-mm high resin "crown" was built-up with resin composite. Teeth were stored for 24 hours in distilled water at 37ºC and prepared for micro-tensile testing. Each specimen was mounted in a testing jig attached to a universal testing machine and stressed in tension at a crosshead speed of 0.5mm/min until failure. The means of tensile bond strength were (MPa): A- 21.42 ± 7.52ª; B- 30.13 ± 10.19ª; C- 31.69 ± 11.78ª; D- 30.69 ± 8.47ª and E- 35.66 ± 9.54ª. No statistically significant difference was observed among the age groups (p > 0.05). The results suggested that the tensile bond strength of the adhesive system was not significantly affected by dentin aging.Este estudo avaliou, in vitro, o efeito da idade na resistência à tração do sistema adesivo Prime & Bond NT no substrato dentinário. Foram utilizados terceiros molares humanos de cinco faixas etárias: A- 17 a 20, B- 21 a 30, C- 31 a 40, D- 41 a 50 e E- 51 a 63. O esmalte oclusal foi removido utilizando disco de diamante e a superfície dentinária abrasionada e planificada com lixa de SiC (600) sob refrigeração. O sistema adesivo foi aplicado de acordo com as recomendações do fabricante e um bloco de resina composta de 6 mm de altura foi confeccionado na superfície dentinária. Os dentes foram armazenados em água por 24 horas a 37ºC e preparados para o ensaio de micro-tração. Cada espécime foi fixado no dispositivo de micro-tração que estava acoplado a uma máquina universal de ensaio e testado numa velocidade de 0,5 mm/min. As médias de resistência à tração foram (MPa): A- 21,42 ± 7,52ª; B- 30,13 ± 10,19ª; C- 31,69 ± 11,78ª; D- 30,69 ± 8,47ª e E- 35,66 ± 9,54ª. Nenhuma diferença significativa foi observada entre os grupos formados pelas faixas etárias (p > 0,05). Os resultados sugerem que a idade não altera significativamente a resistência de união do sistema adesivo à dentina.
- Published
- 2003
- Full Text
- View/download PDF
17. Influência da hibridização prévia a cimentação temporária na resistência de união de pinos de fibra de vidro à dentina radicular
- Author
-
Isa Maria de Oliveira Mariano, Santos Filho, Paulo César de Freitas, Menezes, Murilo de Sousa, and Silva, André Luis Faria e
- Subjects
Bond strength ,Cimentos dentários ,Pinos de fibra ,Intraradicular post retention ,Pinos dentários ,CIENCIAS DA SAUDE::ODONTOLOGIA [CNPQ] ,Resin cements ,Retenção de pino intra-radicular ,Fiber posts ,Root dentin ,Cimentos resinosos ,Dentina radicular ,Dentina ,Resistência de união - Abstract
The aim of this study was to evaluate the influence of resin coat prior temporary cementing on bonding strength of fiber post to root dentine. Seventy-eight bovine tooth were sectioned and roots 15 mm in length were treated endodontically and prepared to receive the post. Sixty roots were used for mechanical testing of micro push-out, being that in a group the Clearfil SE Bond was applied before the temporary cementation to prepare the dentin, while while in the other group the Clearfil SE Bond before temporary cementation was not applied. Three types of temporary cement for fixation of temporary restorations were, are: calcium hydroxide cement-based, zinc oxide and eugenol cement-based and zinc oxide without eugenol cement-based. After 07 days, the temporary restorations were removed and the root canals were cleaned. The post were treated with 35% hydrogen peroxide and silanized. The post were cemented with self-adhesive cement Rely X U200. The seating of the post was five minutes and the excess was removed after the first 60 seconds. After the outer covering of the roots with the molding material, the samples will be photoactivated for 40 seconds on each surface. The roots were stored for 24 hours and then sectioned into slices for mechanical test micro push-out and analysis of the fracture pattern. Eighteen samples were used for evaluation through confocal laser scanning microscopic to analyze penetration and distribution of the resin cement and adhesive system. Data were analyzed by two-way ANOVA and Tukey test. The results showed that there was no statistically significant interaction between the use of a sealing agent and temporary cement (P = 0.375), excluding root thirds. In conclusion, the use of a sealing agent prior to the temporary cement did not result in higher bond strength of fiber post to the root dentin. O objetivo deste estudo foi avaliar a influência da hibridização prévia a cimentação temporária na resistência de união de pinos de fibra de vidro à dentina radicular. Setenta e oito incisivos bovinos foram seccionados e as raízes com 15 mm de comprimento foram tratadas endodonticamente e preparadas para receber os pinos. Sessenta raízes foram utilizadas para o ensaio mecânico de micropush-out, sendo que em um grupo foi aplicado o sistema adesivo Clearfil SE Bond antes da cimentação temporária para o preparo do substrato dentinário, enquanto que no outro grupo não foi aplicado o sistema adesivo Clearfil SE Bond antes da cimentação temporária. Foram utilizados três tipos de cimento temporário para fixação das restaurações provisórias, sendo eles: cimento à base de Hidróxido de cálcio, cimento à base de óxido de zinco e eugenol e cimento à base de óxido de zinco livre de eugenol. Após 07 dias, as restaurações provisórias foram removidas e os canais radiculares limpos. Os pinos foram tratados com peróxido de hidrogênio 35% e silanizados. Em seguida, os pinos foram cimentados com cimento autoadesivo Rely X U200. O assentamento do pino foi de cinco minutos e o excesso foi removido após os primeiros 60 segundos. Após o recobrimento externo das raízes com material de moldagem, as amostras foram fotoativadas por 40 segundos em cada superfície. As raízes foram armazenadas por 24 horas e, em seguida, seccionadas em fatias para realização do ensaio mecânico de micro push-out e análise do padrão de fratura. Dezoito amostras foram utilizadas para avaliação por meio de Microscopia de Varredura a Laser Confocal para analisar penetração e distribuição do cimento resinoso e sistema adesivo. Os dados foram analisados por two-way ANOVA e teste de Tukey. Os resultados mostraram que não houve interação significativa entre o uso de agente selador e cimento temporário (P = 0,375), desconsiderando os terços radiculares. Em conclusão, a utilização de agente selador prévio ao cimento temporário não resultou em maior resistência de união de pinos de fibra de vidro à dentina radicular. Mestre em Odontologia
- Published
- 2021
- Full Text
- View/download PDF
18. Evaluation of the properties of an adhesive system modified by a peptidic antibacterial
- Author
-
Lopes, Stephanie Ribeiro [UNESP], Universidade Estadual Paulista (Unesp), and Pucci, César Rogério [UNESP]
- Subjects
Bond strength ,Nisina ,Antibacterianos ,Anti-bacterial agents ,Sistema adesivo ,Adhesive system ,Nisin ,Resistência de união - Abstract
Submitted by Stephanie Ribeiro Lopes (stephanie.lopes@unesp.br) on 2021-09-13T14:41:26Z No. of bitstreams: 1 Dissertação Stephanie Ribeiro Lopes.pdf: 1614210 bytes, checksum: 79823adec82475dde8dd2f158494aff3 (MD5) Approved for entry into archive by Silvana Alvarez null (silvana@ict.unesp.br) on 2021-09-14T19:57:13Z (GMT) No. of bitstreams: 1 lopes_sr_me_sjc.pdf: 1614210 bytes, checksum: 79823adec82475dde8dd2f158494aff3 (MD5) Made available in DSpace on 2021-09-14T19:57:13Z (GMT). No. of bitstreams: 1 lopes_sr_me_sjc.pdf: 1614210 bytes, checksum: 79823adec82475dde8dd2f158494aff3 (MD5) Previous issue date: 2021-08-09 Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) O objetivo desse estudo foi avaliar as propriedades de um sistema adesivo modificado com a incorporação de um antibacteriano peptídico, Nisina pura (Handary, Belgium), a qual é amplamente utilizada para conservação de alimentos, em duas diferentes concentrações, 0,5% e 1,0%. Foram avaliados a resistência de união da interface adesiva, o grau de conversão e a atividade antibacteriana, além da análise por meio do Estereomicroscópio e Microscópio Eletrônico de Varredura (MEV). Os adesivos foram divididos em três grupos de acordo com a concentração de nisina (Handary, Belgium) incorporada ao sistema adesivo em cada grupo (n=10): SB – Adesivo Comercial Single Bond 2 (3M-ESPE), SBN05 – Single Bond 2 + Nisina 0,5%, SBN1 - Single Bond 2 + Nisina 1%. Para o teste de resistência de união foram utilizados 30 molares humanos hígidos (n=10). O grau de conversão foi feito por infravermelho por transformada de Fourier (FTIR), onde foram feitas três leituras das gotas do adesivo dos diferentes grupos. A atividade antibacteriana foi feita através dos testes de difusão em ágar e contagem da unidade formadora de colônia (UFC), realizado em triplicata, onde foram utilizados discos de adesivos polimerizados dos diferentes grupos. Os dados foram analisados estatisticamente quanto à sua normalidade. Como estes apresentaram distribuição normal, realizou-se o teste de análise de variância (ANOVA) e o teste de Tukey de 5%. Os resultados obtidos na microtração (MPa±Dp) foram SB 40,69±2,42A, SBN05 39,20±2,21A e SBN1 31,36±2,47B. No grau de conversão obtivemos como resultado SB 83,50±3,42A, SBN05 80,22±3,68A e SBN1 78,44±0,95A. Na atividade antibacteriana em difusão de ágar não houve diferença na formação de áreas de inibição, entretanto na unidade formadora de colônia obtivemos como resultado SB 0,51±0,02A, SBN1 0,36±0,03B e SBN05 0,30±0,04B. Pode-se concluir que a incorporação da nisina não interferiu no grau de conversão e na resistência de união na porcentagem de 0,5%, não apresentou área de inibição em difusão em ágar e apresentou atividade antibacteriana no teste UFC, mostrando seu efeito antibacteriano. The objective of this study was to evaluate the properties of a modified adhesive system with the incorporation of a peptidic antibacterial, pure Nisin (Handary, Belgium), which is widely used for food preservation, in two different concentrations, 0.5% and 1.0%. The bond strength of the adhesive interface, the degree of conversion and antibacterial activity were evaluated, in addition to analysis using the Stereomicroscope and Scanning Electron Microscope (SEM). The adhesives were divided into three groups according to the concentration of nisin (Handary, Belgium) incorporated into the adhesive system in each group (n=10): SB – Single Bond 2 Adhesive (3M-ESPE), SBN05 – Single Bond 2 + Nisin 0,5%, SBN1 - Single Bond 2 + Nisin 1%. For the microtensile bond strength test, 30 healthy human molars (n = 10) were used. The degree of conversion was made in the Fourier transform infrared (FTIR), three readings of the drops of the adhesive of the different groups were made. The antibacterial activity was performed through the agar diffusion tests and colony forming unit (CFU) counting, performed in triplicate, where polymerized adhesive discs from different groups were used. The data were analyzed statistically for normality. As these presented normal distributions, the analysis of variance test (ANOVA) and the Tukey test of 5% were performed. The results obtained in microtensile (MPa±Dp) were SB 40,69±2,42A, SBN05 39,20±2,21A, SBN1 31,36±2,47B. In the degree of conversion, we got as a result SB 83,50±3,42A, SBN05 80,22±3,68A and SBN1 78,44±0,95A. In the antibacterial activity there was no difference in the formation of areas of inhibition. However, in the colony forming unit we obtained as a result SB 0,51±0,02A, SBN1 0,36±0,03B e SBN05 0,30±0,04B. It was concluded that the incorporation of nisin did not influence the degree of conversion of the adhesive and in the bond strength in the percentage of 0.5%, presented antibacterial activity (CFU), showing its antibacterial effect. 88882.434250/2019-01
- Published
- 2021
19. Effect of endodontic sealers and cleaning the post-space on the bond strength of endodontically treated teeth
- Author
-
Bohrer, Thaís Camponogara, Kaizer, Osvaldo Bazzan, Bier, Carlos Alexandre Souza, Skupien, Jovito Adiel, Fraga, Sara, and Wandscher, inícius Felipe
- Subjects
Bond strength ,Espaço do pino ,CIENCIAS DA SAUDE::ODONTOLOGIA [CNPQ] ,Revisão ,Post-space ,Review ,Endodontic sealer ,Cimentos endodônticos ,Resistência de união - Abstract
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES In the present study, divided into three parts, the influence of endodontic sealers and post-space treatment differents for cleaning the post-space on the post-dentin bond strength was evaluated. The first study aimed to systematically review the literature evaluating the influence of endodontic sealers on the post-dentin bond strength. A search was performed in the PubMed/MEDLINE, Lilacs, and Scopus databases without language limit or year of publication. A total of 65 studies out of 891 potentially eligible studies were selected for reading, thus 27 studies were included in the review. The meta-analysis found that there is a significant influence of the endodontic sealer on the post-dentin bond strength. Therefore, the second part of the present study aimed to systematically review the literature to evaluate the influence of the post-space treatment on the bond strength of intraradicular posts to root dentin. Just like in the first part, a search was performed in the databases mentioned above, with no limits on language or year of publication. Of 2832 potentially eligible studies, 453 were selected for reading, and 75 were included in the systematic review. In the overall meta-analysis, the post-space treatment significantly increased the bond strength of the intraradicular post to dentin. In this study, the best treatments were alcohol, NaOCl + EDTA, NaOCl + EDTA+ ultrasound, Er:YAG laser, Nd:YAG laser, and diode laser. The third part evaluated the influence of post-space cleaning treatments, using three types of endodontic sealers for root canal filling, on the bond strength of fiber posts to dentin, and cleaning the post-space. To performed the study, 240 bovine teeth were cleaned and cut in 16 mm and the endodontic treatment was carried out, filling the canals with three endodontic sealers (based on epoxy resin, based on zinc oxide and eugenol, and bioceramic cement). Afterward, the teeth were stored for 24 hours or 6 months in an oven at 37°C. After that, the preparations for the post were made and different cleaning treatments were applied (distilled water, NaOCl + EDTA, 99% alcohol, and diode laser). The specimens were cut into slices with the aid of a cutting machine and, after, submitted to the push-out test. Also, twelve teeth were endodontically treated and filled with the different endodontic sealers studied. After the post-space was prepared, the different cleanings treatments were applied and the specimens were cut along the tooth axis and analyzed under the scanning electron microscope. Thus, we verified that the NaOCl + EDTA treatment obtained higher results for post-dentin bond strength, and we observed adequate cleanliness of the post space after using this treatment. No presente trabalho, dividido em três partes, foi avaliado a influência dos cimentos endodônticos e dos diferentes tratamentos para limpeza do espaço para o pino na resistência de união de pinos intrarradiculares à dentina radicular. O primeiro estudo teve o objetivo de revisar sistematicamente a literatura avaliando a influência dos cimentos endodônticos na resistência de união dos pinos à dentina. Uma busca foi realizada nas bases de dados PubMed/MEDLINE, Lilacs e Scopus sem limite de linguagem ou de ano de publicação. Um total de 65 estudos entre 891 estudos potencialmente elegíveis foram selecionados para leitura, sendo selecionado 27 estudos para inclusão na revisão. A meta-análise verificou que há influência significativa do cimento endodôntico na resistência de união do pino à dentina radicular. A segunda parte do presente trabalho teve como objetivo revisar sistematicamente a literatura para avaliar a influência do tratamento para limpeza do espaço confeccionado para o pino na resistência de união de pinos intrarradiculares à dentina radicular. Da mesma forma que na primeira parte, foi realizada uma busca nas bases de dados citadas acima, sem limites de linguagem ou de ano de publicação. De 2832 estudos potencialmente elegíveis, 453 foram selecionados para a leitura e 75 estudos foram incluídos na revisão sistemática. Na meta-análise geral, o tratamento do espaço para o pino aumentou significativamente a resistência de união do pino intrarradicular à dentina. Neste estudo, os melhores tratamentos foram, respectivamente, álcool, NaOCl + EDTA, NaOCl + EDTA+ ultrassom, laser de Er: YAG, laser de Nd: YAG e laser de diodo. A terceira parte avaliou a influência dos tratamentos de limpeza do espaço para o pino de fibra de vidro, utilizando três tipos de cimentos endodônticos para obturação do canal radicular, na resistência de união de pinos à dentina e na limpeza do espaço para o pino. Para a realização do estudo, 240 dentes bovinos foram limpos e cortados em 16 mm e o tratamento endodôntico foi realizado, obturando os canais com três cimentos endodonticos (à base de resina epóxica, à base de óxido de zinco e eugenol e cimento biocerâmico). Após, os dentes foram armazenados por 24 horas ou por 6 meses em estufa a 37°C. Feito isso, os preparos para o pino foram confeccionados e neles aplicados diferentes tratamentos de limpeza (água destilada, NaOCl + EDTA, álcool a 99% e laser de diodo). Logo, os espécimes foram cortados em slices com auxílio de uma máquina de corte e, após, submetidos ao teste de push-out. Ainda, doze dentes foram tratados endodonticamente e obturados com os diferentes cimentos endodônticos estudados, após preparado o espaço para o pino, os diferentes tratamentos de limpeza foram aplicados, os espécimes foram cortados no longo do eixo do dente e submetidos à análise no microscópio eletrônico de varredura. Com isso, verificamos que o tratamento NaOCl + EDTA obteve os melhores resultados de resistência de união do pino à dentina e foi observada uma adequada limpeza do espaço do pino após a utilização desse tratamento.
- Published
- 2021
20. Durabilidade da união à dentina e liberação de cálcio promovidas por sistemas adesivos experimentais com adição de hidróxido de cálcio
- Author
-
Amorim, Débora Michelle Gonçalves de, Lima, Renally Bezerra Wanderley e, Maia, Conceição Aparecida Dornelas Monteiro, Araújo, Diana Ferreira Gadelha de, Assunção, Isauremi Vieira de, and Borges, Boniek Castillo Dutra
- Subjects
Adesivos dentinários ,Hidróxido de cálcio ,Resistência de união - Abstract
Objetivo: Este estudo investigou a liberação de cálcio (CaR) e estabilidade de adesão à dentina em longo prazo (DBS) de sistemas adesivos autocondicionantes experimentais contendo hidróxido de cálcio. Metodologia: Quatro sistemas adesivos foram formulados incluindo monômeros UDMA, HEMA, GDMA-P, TPO e difenil iodônio como sistema fotoiniciador, e etanol / água como solvente com diferentes frações de massa de hidróxido de cálcio: 0% (controle), 1%, 2% e 4%. O DBS foi medido pelo método de microtração de resistência de união em máquina de ensaio de microtração. O terço médio da dentina de 24 terceiros molares humanos (n = 6) foi usado para unir os sistemas adesivos a uma resina composta. Amostras em forma de palitos (1 mm2 ) foram obtidas após 24 horas de imersão em água destilada e testadas imediatamente e após 12 meses de armazenamento em água. Os dados foram avaliados estatisticamente por meio de ANOVA de dois fatores e pós-teste de Tukey (p
- Published
- 2021
21. CAPACIDADE DE UNIÃO DE UM NOVO SISTEMA ADESIVO À DENTINA.
- Author
-
Somacal, Deise Caren and Spohr, Ana Maria
- Abstract
O objetivo do trabalho foi verificar a resistência de união à dentina do novo sistema adesivo Single Bond Universal (3M) quando aplicado com o condicionamento ácido prévio e quando utilizado na forma autocondicionante. Como grupo controle, foram utilizados os sistemas adesivos Scothbond MultiPurpose (3M), que emprega o condicionamento ácido prévio, e o Clearfil SE Bond (Kuraray), que é autocondicionante. As raízes de 24 dentes terceiros molares humanos foram incluídas em resina acrílica quimicamente ativada. A superfície oclusal em esmalte foi removida para exposição da dentina, seguido de acabamento com lixas de carbeto de silício de granulação 600. Os dentes foram divididos aleatoriamente em quatro grupos (n=6/grupo): Grupo 1 – Single Bond Universal com aplicação do condicionamento ácido prévio; Grupo 2 – Single Bond Universal na forma autocondicionante; Grupo 3 – Scothbond MultiPurpose; Grupo 4 – Clearfil SE Bond. Sobre o sistema adesivo foi construído um bloco em resina composta. Após armazenagem em água destilada a 37º C por 24 horas, os conjuntos dente/resina foram cortados paralelamente ao longo eixo do dente, nos sentidos x e y, com secção de aproximadamente 0,80 mm2. Foram obtidos 20 corpos de prova na forma de “palitos” para cada grupo, sendo então submetidos ao teste de resistência à microtração em máquina de ensaio universal com velocidade de 0,5 mm/min. De acordo com a Análise de Variância, não houve diferença estatística (p>0,05) entre os grupos: Grupo 1= 39,37 MPa (±10,82); Grupo 2= 31,02 MPa (±13,76); Grupo 3= 35,09 MPa (±14,03); Grupo 4= 35,84 MPa (±11,06). O novo sistema adesivo Single Bond Universal demonstrou capacidade de união à dentina comparável aos sistemas adesivos utilizados como controle. [ABSTRACT FROM AUTHOR]
- Published
- 2016
22. The effect of different solutions on bond strength of two root canal sealers.
- Author
-
Dalbem, Fernanda, de Carli, Sabrina, Farina, Ana Paula, de Moraes Souto Pantoja, Carlos Augusto, Randi Ferraz, Caio Cezar, and Cecchin, Douglas
- Subjects
DENTAL bonding ,ANALYSIS of variance ,ANIMAL experimentation ,BIOLOGICAL models ,CATTLE ,CHLORHEXIDINE ,STATISTICAL correlation ,DENTAL materials ,ETHYLENEDIAMINETETRAACETIC acid ,INCISORS ,MATERIALS testing ,PROBABILITY theory ,SODIUM hypochlorite ,SOLUTION (Chemistry) ,STATISTICS ,TOOTH roots ,DATA analysis ,DESCRIPTIVE statistics - Abstract
Copyright of Revista Odonto Ciencia is the property of EDIPUCRS - Editora Universitaria da PUCRS and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
- Published
- 2015
- Full Text
- View/download PDF
23. Resitencia de la unión de los sistemas adhesivos en dentina húmeda y en dentina seca: revisión integradora
- Author
-
Oliveira, Hiully Karydja Câmara, Lima, Isabela Pinheiro Cavalcanti, Oliveira, Hugo Matheus Câmara, Lima, Nara Grazieli Martins, Pinto, Talita da Silva, Regis, Matheus da Silva, and Medeiros, Heloísa Pereira de
- Subjects
Union Endurance ,Resistencia de la unión ,Clinical protocols ,Dentin ,Protocolos clínicos ,Sistemas adesivos ,Dentina ,Sistemas adhesivos ,Adhesive systems ,Resistência de união - Abstract
Adhesion to dentin is difficult because it is a structure with high water composition, over the years the clinical protocols, as well as the adhesive systems have been changed, in order to improve the union endurance and simplify the technique. Through a integrative review, discuss the union endurance of adhesive systems in wet and dry dentin in order to improve clinical protocols. The selection of articles was carried out through the virtual health library (VHL), obtaining articles from the MEDLINE, LILACS, Biblioteca Brasileira de Odontologia (BBO) databases, in addition to searches on Google® Scholar, using the indexed terms: “Dentin”, “Dentina”, "Dentin-Bonding Agents" and “Adesivos dentinários”. Articles published between 2013 and 2020 were included. The selected studies could be clinical or laboratory, in wet and dry dentin, using tensile, microtensile or shear strength tests in the studies in vitro, with conventional, self-etching and / or universal adhesive systems, published as short articles, posters or literature reviews were excluded. 969 were found, 8 articles were selected according to the inclusion criteria, all studies addressed the degree dentin moisture content as a limiting factor in the quality of adhesion, as well as the operator's knowledge about the composition of the adhesive system used. Universal adhesive systems were effective on both wet and dry dentin, conventional adhesive systems were efficient only on wet dentin. La adherencia a la dentina es obstaculizada porque es una estructura con alta composición hídrica, a lo largo de los años los protocolos clínicos, así como los sistemas adhesivos han sido cambiados, con el objetivo de mejorar la resistencia de la unión y simplificar la técnica. Por medio de una revisión integradora, exponer sobre la resistencia de la unión de los sistemas adhesivos en dentina húmeda y en dentina seca com el objetivo de mejorar los protocolos clínicos. La selección de los artículo fue realizada a través de a biblioteca virtual en salud (BVS), consiguiendo artículos de las bases MEDLINE, LILACS, Biblioteca Brasileira de Odontologia (BBO), además de búsquedas en Google® Scholar, utilizando los términos indexados: “Dentin”, “Dentina”, "Dentin-Bonding Agents" e “Adesivos dentinários”. Han sido incluido artículos publicados entre 2013 y 2020. Los estudios seleccionados podrían ser clínicos o laboratoriales, en dentina húmeda y en dentina seca, utilizando testes de resistencia a la tracción, microtracción o cizallamiento en los estudios in vitro, com los sistemas adhesivos convencionales, autoacondicionantes y/o universales. Han sido excluídas publicaciones como artículos cortos, carteles o revisiones de literatura. Fueron encontrados 969, habiendo sido seleccionados 8 artículos según los criterios de inclusión, todos los estudios presentaron el grado de humedad de la dentina como un factor limitante en la calidad de adherencia, así como el conocimiento del operador respecto a de la composición del sistema adhesivo utilizado. Los sistemas adhesivos universales han sido efectivos tanto en dentina húmeda como en dentina seca, los sistemas adhesivos convencionales fueron eficientes sólo en dentina húmeda. A adesão à dentina é dificultada por se tratar de uma estrutura com alta composição hídrica, ao longo dos anos os protocolos clínicos, assim como os sistemas adesivos foram sendo alterados, visando melhorar a resistência de união e simplificar a técnica. Por meio de revisão integrativa, discorre-se aqui sobre a resistência de união dos sistemas adesivos em dentina úmida e em dentina seca visando sugerir melhorias dos protocolos clínicos. Selecionou-se os artigos através da biblioteca virtual em saúde (BVS), obtendo-os das bases MEDLINE, LILACS, Biblioteca Brasileira de Odontologia (BBO), além de buscas no Google® Scholar, usando os termos indexados: “Dentin”, “Dentina”, "Dentin-Bonding Agents" e “Adesivos dentinários”. Incluiu-se artigos publicados entre 2013 e 2020. Os estudos selecionados poderiam ser clínicos ou laboratoriais, em dentina úmida e em dentina seca, usando testes de resistência à tração, microtração ou cisalhamento nos estudos in vitro, com os sistemas adesivos convencionais, autocondicionantes e/ou universais. Foram excluídos artigos curtos, pôsteres ou revisões de literatura. Encontrou-se 969 artigos, sendo selecionados 8 deles, segundo os critérios de inclusão, todos os estudos abordavam o grau de umidade da dentina como um fator limitante na qualidade de adesão, assim como o conhecimento do operador a respeito da composição do sistema adesivo utilizado. Os sistemas adesivos universais foram eficazes tanto em dentina úmida quanto em dentina seca, já os sistemas adesivos convencionais foram eficientes apenas em dentina úmida.
- Published
- 2021
24. Influência do tratamento superficial na resistência de união dos reparos de resina composta
- Author
-
Rafael Schneider, João Felipe Mota Pacheco, and Ewerton Nocchi Conceição
- Subjects
resina composta ,reparos ,resistência de união ,Dentistry ,RK1-715 - Abstract
Este estudo avaliou, in vitro, a resistência de união de seis técnicas diferentes de tratamento superficial em reparos de resina composta. Os maiores valores de resistência de união foram obtidos com o tratamento superficial utilizando-se ácido fosfórico, aplicação de um agente de silanização e aplicação do adesivo.
- Published
- 1997
- Full Text
- View/download PDF
25. Avaliação da resistência da união ao esmalte de bráquetes ortodônticos colados com diferentes materiais adesivos
- Author
-
Lisa Klein Zanini, José Renato Prietsch, Ewerton Nocchi Conceição, and Diego Azevedo Bastian Manfredi
- Subjects
resistência de união ,esmalte ,adesivos ,Dentistry ,RK1-715 - Abstract
O objetivo deste trabalho foi analisar a resistência da união ao esmalte de diferentes materiais adesivos na colagem de bráquetes ortodônticos. Foram utilizados 40 incisivos inferiores humanos hígidos extraídos, divididos aleatoriamente em 4 grupos. No grupo A, foi utilizada resina composta quimicamente ativada (Concise/3M) segundo técnica de diluição; no grupo B, utilizou-se a mesma resina do grupo A, porém seguindo as instruções do fabricante; no grupo C, associou-se "primer" ortodôntico (Ortho-one/Bisco) com resina fluoretada (Resinomer/Bisco); e no grupo D, utilizou-se a combinação de resina fluida (Concise/3M) com cimento de ionômero de vidro (Vitremer cimentação/3M). Após o embutimento e armazenamento dos corpos de prova a 37°C, por 24 horas, foi realizado o ensaio de resistência de união, na máquina de ensaio universal (Losenhausenwerk, Germany). Os resultados foram submetidos a Análise de Variância e ao Teste de Tukey (p
- Published
- 1997
- Full Text
- View/download PDF
26. Efectos de aplicación de ácido fosfórico y microarenado en adhesivos autograbadores de uno y dos pasos.
- Author
-
Gómez-Carreño, Alba Lucía, Prada-Espinosa, Laura Isabel, Barrios-Bastidas, Henry Alexander, Peña-Castillo, Mauricio, López-López, Edgar Alexander, Monguel-Gómez, Osnara María, and Domínguez, John Alexis
- Abstract
Copyright of Revista Nacional de Odontología is the property of Universidad Cooperativa de Colombia and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
- Published
- 2015
- Full Text
- View/download PDF
27. Effect of sodium ascorbate on composite resin bond strength to bleached teeth.
- Author
-
Carvalho Xavier, Ana Claudia, Martins Gomes, Ana Paula, Galera da Silva, Eduardo, de Souza Assis, Luciane Navarro, and Pagani, Clóvis
- Subjects
DENTAL bonding ,ANALYSIS of variance ,BICUSPIDS ,DENTAL resins ,DENTAL fillings ,HYDROGEN peroxide ,SODIUM compounds ,STATISTICS ,TOOTH whitening ,VITAMIN C ,DATA analysis ,ARTIFICIAL saliva - Abstract
Copyright of Revista Odonto Ciencia is the property of EDIPUCRS - Editora Universitaria da PUCRS and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
- Published
- 2014
- Full Text
- View/download PDF
28. Análise das propriedades estruturais, morfológicas e mecânicas de duas marcas comerciais diferentes de dissilicato de lítio para o sistema CAD/CAM
- Author
-
Lucas do Nascimento Tavares, Neves, Flávio Domingues das, Zancopé, Karla, and Fernandes, Cláudio Pinheiro
- Subjects
CIENCIAS DA SAUDE::ODONTOLOGIA [CNPQ] ,Sistema CAD/CAM ,DRX ,Microcisalhamento ,Odontologia ,Microscopia eletrônica de varredura ,Flexural strength ,MEV ,CAD/CAM system ,Microshear bond strength ,SEM ,Litio ,Resistência flexural ,Lithium disilicate ,Dissilicato de lítio ,Resistência de união - Abstract
O objetivo deste presente estudo foi comparar duas marcas comerciais diferentes de Dissilicato de Lítio para o sistema CAD / CAM (IPS e.max CAD e Rosetta SM CAD / CAM), avaliando suas propriedades estruturais, morfológicas e mecânicas. Para avaliar as propriedades estruturais foram necessárias duas amostras de cada grupo, para serem analisadas por meio do DRX (difração de raios X). As propriedades morfológicas foram analisadas utilizando o MEV (Microscopia eletrônica de Varredura) antes e depois do tratamento térmico, e o teste de porosidade, realizado através de uma tomografia computadorizada em 3D (micro-CT). Para avaliar as propriedades mecânicas foi realizado o teste flexural de três pontos e o teste de microcisalhamento, e para isto foram selecionados dez espécimes de cada grupo para cada teste. Os valores médios de porosidade e da resistência flexural de três pontos foram analisados pelo teste t e a resistência de união obtida através do microcisalhamento foi analisada pelo teste Anova Two-way. Todos os testes usaram um nível de significância de α = 0,05. Os resultados obtidos pela análise estrutural realizada pelo DRX apresentaram picos no difractograma correspondentes ao Metassilicato de Lítio e o Dissilicato de Lítio, com intensidades semelhantes para ambos os grupos testados. Após realizar a microscopia eletrônica de varredura, não foi encontrado diferenças na morfologia dos cristais, em ambas as cerâmicas testadas, antes e depois do tratamento térmico. O teste de porosidade não mostrou diferença estatisticamente significativa entre o valor total de poros encontrados. Ambos os resultados dos testes mecânicos não apresentaram diferenças estatísticas significativas entre os grupos avaliados. Baseado nos resultados encontrados, não houve diferença entre as duas marcas comerciais testadas, em relação as suas propriedades estruturais, morfológicas e mecânicas. The aim of the present study was to compare two different brands of lithium disilicate CAD/CAM blocks (IPS e.max CAD and Rosetta SM CAD/CAM), evaluated by structural, morphological and mechanical properties. Two specimens of each group were analyzed using x-ray diffraction (XRD) to evaluate the structures of the ceramic material. Morphologic properties were analyzed using the Scanning Electron Microscopy (SEM) before and after the heat treatment; and porosity test was performed using a 3D micro-computed tomography analyses (micro-CT). Ten specimens of each group were submitted to three-point flexure strength and microshear bond strength tests, to analyze the mechanical properties of both brands. Mean values of porosity test and three-axial flexural strength were analyzed by t Test, and the microshear bond strength was analyzed by Anova two-way. All tests used a significance level of α=0.05. The structure results performed by XDR, presented high peak positions corresponding to the standard lithium metasilicate and lithium disilicate, with similar intensities for both tested groups. The morphologic results demonstrated similar patterns of crystalline structure, before and after the heat treatment and the porosity test showed no difference between the number and size of the pores found. Both mechanical tests results did not present statistically significant differences between the samples. Based on the results, there was no difference in relation to their structural, morphological and mechanical properties, between the two commercial brands tested. Dissertação (Mestrado)
- Published
- 2020
- Full Text
- View/download PDF
29. Effect of different times of a self-etching ceramic primer on the adhesion and fatigue behavior of a lithium disilicate ceramic
- Author
-
Dapieve, Kiara Serafini, Valandro, Luiz Felipe, Venturini, Andressa Borin, Aurélio, Iana Lamadrid, and Guilardi, Luís Felipe
- Subjects
Análise de sobrevida ,Bond strength ,Cerâmica vítrea ,CIENCIAS DA SAUDE::ODONTOLOGIA [CNPQ] ,Tratamentos de superfície ,Surface treatments ,Microshear ,Microcisalhamento ,Survival analysis ,CAD/CAM ,Resistência de união ,Glass ceramic - Abstract
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES This dissertation is composed of two studies. Study 1 aimed to evaluate the effect of different etching times of the ceramic primer (E&P, Monobond Etch & Prime) on the durability of the microshear bond strength (μSBS) between a lithium disilicate ceramic and a resin cement. The ceramic samples were subjected to an in-lab simulation of Computer-aided design/Computer-aided manufacturing (CAD/CAM) milling and randomly allocated considering: “surface treatment” - 5% hydrofluoric acid and silane (HF5 + SIL) or E&P (20s+40s; 20s+2min; 20s+5min; 20s+10min); and “aging condition”: short-term (tested 24 h after bonding) or long-term (stored for 180 days + 12,000 thermal cycles). Thereby, resin cement cylinders were built, submitted to the μSBS test and the failure pattern was determined. In the short-term, all groups presented statistically similar bond strength (22.42 – 25.06 MPa). However, only the E&P20s+40s (19.25 MPa) and E&P20s+5min (21.51 MPa) groups maintained a stable long-term bond strength, in which the latter was statistically higher than HF5+SIL (17.05 MPa). Most failures were predominantly adhesive. Thus, the use of ceramic primer is a viable alternative to conditioning with 5% hydrofluoric acid and silane, providing a stable bond strength for passive application of 40 s or 5 min. Study 2 aimed to evaluate the effect of increased time of passive application of ceramic primer on the fatigue performance of adhesively cemented lithium disilicate simplified restorations. Ceramic discs (Ø= 10mm; thickness= 1.0mm) were submitted to the same CAD/CAM simulation process and allocated according to: “surface treatment” - PRIMER, coupling agent application only; HF5 + PRIMER, 5% hydrofluoric acid and coupling agent; E&P20s+40s and E&P20s+5min, etching with E&P for 20 s of active application followed by 40 s or 5 min of passive application, respectively; and “aging condition” - baseline, tests performed after 24 h within 5 days of cementation; or aged, storage for 90 days of storage + 12,000 thermal cycles. The adhesive cementation was performed onto epoxy resin discs (Ø= 10 mm; thickness= 2 mm) and the cemented assemblies were submitted to the fatigue test by step-stress approach (initial load of 200 N; step-size of 50 N for each 10,000 cycles; 20 Hz). In the baseline condition, the surface treatments presented similar fatigue performance, except for E&P20s+5min group (940.0 N; 123,000), which presented higher value than PRIMER (786.7 N; 92,333). When aged, the PRIMER group had worst fatigue performance (480.8 N; 31,154) compared to the other groups (810.0 – 840.0 N; 97,000 – 103,000 cycles). In addition, treatment with PRIMER showed unstable fatigue performance after aging. Thus, etching the ceramic surface is required for stable fatigue performance of adhesively cemented lithium disilicate restorations. In addition, the E&P ceramic primer promoted similar fatigue performance compared to the treatment with 5% hydrofluoric acid and coupling agent, but the passive increase in etching time did not improve the fatigue behavior. A presente dissertação é composta por dois estudos. O estudo 1 teve como objetivo avaliar o efeito de diferentes tempos de condicionamento do primer cerâmico (E&P, Monobond Etch & Prime) na durabilidade da resistência de união ao microcisalhamento (μSBS) entre uma cerâmica de dissilicato de lítio e um cimento resinoso. As amostras de cerâmica foram submetidas à simulação em laboratório da usinagem pelo Computer-aided design/Computer-aided manufacturing (CAD/CAM) e alocadas aleatoriamente considerando: “tratamento de superfície” - ácido fluorídrico 5% e silano (HF5+SIL) ou E&P (20s+40s; 20s+2min; 20s+5min; 20s+10min); e “condição de envelhecimento”: curto prazo (testados 24 h após a cimentação) ou longo prazo (armazenados por 180 dias + 12.000 ciclos térmicos). Assim, cilindros de cimento resinoso foram confeccionados, submetidos ao teste de μSBS e o padrão de falha foi determinado. A curto prazo, todos os grupos apresentaram resistência de união estatisticamente semelhantes (22,42 – 25,06 MPa). No entanto, apenas os grupos E&P20s+40s (19,25 MPa) e E&P20s+5min (21,51 MPa) mantiveram uma resistência adesiva estável a longo prazo, na qual este último foi estatisticamente superior ao HF5+SIL (17,05 MPa). A maioria das falhas foram predominantemente adesivas. Portanto, o uso do primer cerâmico mostra-se uma alternativa viável ao condicionamento com ácido fluorídrico 5% e silano, promovendo uma resistência de união estável para aplicação passiva de 40 s ou 5 min. O estudo 2 teve como objetivo avaliar o efeito do aumento de tempo da aplicação passiva do primer cerâmico no desempenho à fadiga de restaurações simplificadas de dissilicato de lítio cimentadas adesivamente. Discos (Ø= 10mm; espessura= 1,0mm) de cerâmica foram submetidos ao mesmo processo de simulação CAD/CAM e alocados segundo: “tratamento de superfície” - PRIMER, somente aplicação de silano; HF5+PRIMER, ácido fluorídrico 5% e silano; E&P20s+40s e E&P20s+5min, condicionamento com E&P durante 20 s de aplicação ativa seguida de 40 s ou 5 min de aplicação passiva, respectivamente; e “condição de envelhecimento” - baseline, testes realizados após 24 h até 5 dias da cimentação; ou envelhecidos, armazenamento por 90 dias + 12.000 ciclos térmicos. A cimentação adesiva foi realizada sobre discos de resina epóxi (Ø= 10 mm; espessura= 2 mm) e os conjuntos cimentados foram submetidos ao teste de fadiga pela abordagem stepstress (carga inicial de 200 N; incremento de carga de 50 N a cada 10.000 ciclos; 20 Hz). Na condição baseline, os tratamentos de superfície apresentaram desempenho semelhante à fadiga, com exceção do grupo E&P20s+5min (940,0 N; 123.000), que apresentou valor superior ao PRIMER (786,7 N; 92.333). Quando envelhecido, o grupo PRIMER apresentou pior desempenho à fadiga (480,8 N; 31.154) em comparação aos outros grupos (810,0 – 840,0 N; 97.000 – 103.000 ciclos). Além disso, o tratamento com PRIMER apresentou desempenho instável à fadiga após envelhecimento. Assim, condicionar a superfície da cerâmica é necessário para um desempenho estável em fadiga de restaurações de dissilicato de lítio cimentadas adesivamente. Ademais, o primer cerâmico E&P promoveu desempenho semelhante à fadiga comparado ao tratamento com ácido fluorídrico 5% e agente de união, mas o aumento passivo no tempo de condicionamento não melhorou o comportamento à fadiga.
- Published
- 2020
30. Effect of chlorhexidine concentration on the bond strength to dentin in primary teeth.
- Author
-
Grings Manfro, Aline Rosler, Reis, Alessandra, Loguercio, Alessandro Dourado, Pettorossi Imparato, José Carlos, and Raggio, Daniela Prócida
- Subjects
CHLORHEXIDINE ,DECIDUOUS teeth ,DENTIN ,ADHESIVES ,MOLARS ,PHOSPHORIC acid ,WATER ,DISTILLED water ,TEETH - Abstract
Copyright of Revista Odonto Ciencia is the property of EDIPUCRS - Editora Universitaria da PUCRS and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
- Published
- 2010
- Full Text
- View/download PDF
31. Effect of saliva contamination on the bond strength of an etch-and-rinse adhesive system to dentin.
- Author
-
Guerriero, Luciana Neves, Vieira, Samuel Nilo, Scaramucci, Taís, Kawaguchi, Fernando Aparecido, Pita Sobral, Maria Angela, and Matos, Adriana Bona
- Subjects
DROOLING ,DENTIN ,INCISORS ,ACRYLIC resins ,CONTROL groups ,DENTAL resins ,DENTAL adhesives - Abstract
Copyright of Revista Odonto Ciencia is the property of EDIPUCRS - Editora Universitaria da PUCRS and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
- Published
- 2009
32. Avaliação da resistência de união de restaurações de resina composta com diferentes sistemas adesivos, em dois tempos de armazenamento.
- Author
-
Dellazzana, Fernando Zurlo, Coelho-De-Souza, Fábio Herrmann, and Klein-Júnior, Celso Afonso
- Subjects
DENTAL bonding ,DENTAL resins ,DENTIN ,TREATMENT of molar abnormalities ,PIT & fissure sealants (Dentistry) - Abstract
Copyright of Revista da Faculdade de Odontologia is the property of UFRGS-Faculdade de Odontologia and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
- Published
- 2008
- Full Text
- View/download PDF
33. Resistência de união à microtração de sistemas adesivos 'condiciona-e-lava' de dois passos: efeito de diferentes tratamentos da superfície dentinária condicionada
- Author
-
Edson Alves de Campos, Mateus Rodrigues Tonetto, Tamíris da Costa Neves, Thais Piragine Leandrin, and Marcelo Ferrarezi de Andrade
- Subjects
etanol ,0206 medical engineering ,lcsh:R ,lcsh:Medicine ,030206 dentistry ,02 engineering and technology ,General Medicine ,020601 biomedical engineering ,Adesivos dentinários ,lcsh:RK1-715 ,03 medical and health sciences ,0302 clinical medicine ,dentina ,lcsh:Dentistry ,resistência de união ,clorexidina - Abstract
Resumo Introdução A evolução dos sistemas adesivos permitiu que os fabricantes desenvolvessem materiais com técnicas cada vez mais simplificadas, porém que, ainda assim, promovessem adequados valores de resistência de união imediata. Sugere-se que alguns tratamentos da superfície dentinária podem favorecer esse processo de adesão. Objetivo Avaliar os efeitos de diferentes tratamentos, em superfície dentinária plana condicionada, sobre a resistência de união à microtração de sistemas adesivos do tipo “condiciona-e-lava” de dois passos. Material e método Noventa e seis terceiros molares humanos foram divididos em 12 grupos (n=8), aleatoriamente, de acordo com o sistema adesivo utilizado (GI: Adper Single Bond 2 - 3M ESPE; GII: Prime & Bond 2.1 - Dentsply; GIII: Excite - Ivoclar Vivadent) e o tipo de tratamento do substrato dentinário condicionado (a: água; b: clorexidina + água; c: etanol; d: clorexidina + etanol). Todos os dentes foram restaurados com resina Charisma na cor A2 (Heraeus - Kulzer, Germany) e submetidos a ensaio mecânico de microtração (EMIC DL-2000). O teste estatístico realizado foi ANOVA a um fator, completado com teste de Tukey. Resultado Os grupos GIIc, GIIIc e GIId apresentaram aumento significativo estatisticamente na resistência de união à microtração imediata. Conclusão Os diferentes tratamentos da dentina condicionada não afetaram de maneira negativa a resistência de união para todos os sistemas adesivos testados e a utilização da técnica com etanol, associado ou não à clorexidina, parece ser uma interessante abordagem quando associada a sistemas adesivos “condiciona-e-lava” de dois passos.
- Published
- 2017
34. Influence of etching techniques of CAD/CAM ceramics on surface roughness, topography and bond strength of resin cement
- Author
-
Azevedo, Veber Luiz Bomfim, 1988, Cavalli, Vanessa, 1977, Giannini, Marcelo, 1969, Andrade, Oswaldo Scopin de, Basting, Roberta Tarkany, França, Fabiana Mantovani Gomes, Lobo, Maristela Maia, Universidade Estadual de Campinas. Faculdade de Odontologia de Piracicaba, Programa de Pós-Graduação em Clínica Odontológica, and UNIVERSIDADE ESTADUAL DE CAMPINAS
- Subjects
Cerâmica odontológica ,Bond strength ,Dental ceramics ,Desenho assistido por computador ,Dental materials ,Materiais dentários ,Computer-aided design ,Resistência de união - Abstract
Orientadores: Vanessa Cavalli Gobbo, Marcelo Giannini Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba Resumo: Diferentes tratamentos utilizando ácido fluorídrico ou primer cerâmico em diferentes tempos de aplicação, podem influenciar a topografia e a resistência de união de materiais cerâmicos do sistema CAD/CAM. Desta forma, este estudo avaliou a rugosidade de superfície (SA), topografia e resistência de união imediata e de longo prazo de diferentes tratamentos na superfície da cerâmica feldspática (Vitablocks Triluxe [FEL]) e à base de silicato de lítio reforçado por zircônia (Vita Suprinity PC [ZLS]) para CAD/CAM. Duzentas placas (10 mm x 5 mm x 1mm) de FEL e ZLS foram obtidas e submetidas ao condicionamento com ácido fluorídrico (HF ¿ 5% ou 10%) ou aplicação de primer condicionante para cerâmica (MEP - Monobond Etch & Prime) durante diferentes tempos de aplicação (20, 40 ou 60s), de acordo com os grupos: Jateamento (controle); 5%HF 20s; 5%HF 40s; 5%HF 60s; 10%HF 20s; 10%HF 40s; 10%HF 60s; MEP 20s; MEP 40s e MEP 60s. As placas das cerâmicas FEL ou ZLS foram tratadas de acordo os grupos experimentais e dois cilindros de cimento resinoso (1,5 mm de diâmetro x 1,5 mm de altura) foram aderidos a cada placa, e submetidos ao ensaio de resistência de união por cisalhamento (SBS) (n=10), um testado após 24 h e o outro após dezesseis meses de armazenamento em água destilada. A rugosidade de superfície (SA) (n=10) e padrão de condicionamento foram avaliados em microscopia de força atômica (AFM) e eletrônica de varredura (SEM). Os dados foram analisados pela ANOVA dois fatores (rugosidade - SA) e três fatores (cisalhamento - SBS), seguidos pelo teste de Bonferroni (? = 0,05). O teste de Pearson verificou a correlação entre a rugosidade e resistência de união dos blocos cerâmicos imediatamente e após armazenamento. O aumento da concentração de HF ou tempo de aplicação (de HF ou MEP) não influenciou significativamente a rugosidade das cerâmicas (p>0,05). O jateamento e o MEP 40s promoveram maiores valores de SA para os grupos ZLS e o condicionamento com 10% HF promoveu maior rugosidade para FEL. A resistência de união foi menor para os grupos tratados com MEP e os maiores valores de SBS foram observados para o condicionamento com HF (5% ou 10%) (p0.05). Sandblasting and MEP for 40s showed higher SA values for ZLS groups and 10%HF showed higher roughness for FEL. Bond strength was lower for MEP-treated groups and the greatest SBS values were observed for the HF-treated groups, regardless the acid concentration (p
- Published
- 2020
35. Effect of aging time and experimental silanes containing thio-urethane oligomers on the bond strength to lithium glass ceramic
- Author
-
Torso, Victor Hugo, 1994, Correr Sobrinho, Lourenço, 1960, Pfeifer, Carmem Silvia Costa, Neves, José Guilherme, Sousa Neto, Manoel Damião de, Universidade Estadual de Campinas. Faculdade de Odontologia de Piracicaba, Programa de Pós-Graduação em Materiais Dentários, and UNIVERSIDADE ESTADUAL DE CAMPINAS
- Subjects
Bond strength ,Ceramics ,Cimentos resinosos ,Cerâmica ,Adesão ,Silano ,Adhesion ,Silane ,Resin cements ,Resistência de união - Abstract
Orientadores: Lourenço Correr Sobrinho, Carmem Silvia Costa Pfeifer Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba Resumo: O objetivo neste estudo foi avaliar o efeito de silanos formulados com oligômeros de tio-uretano (TU) na resistência da união ao microcisalhamento (RUµC) da cerâmica de vidro à base de dissilicato de lítio (IPS e.max Press) e cimento resinoso após 24 horas ou seis meses de armazenamento em água. Os silanos experimentais contendo 2% em peso de oligômeros de tio-uretano alifático, cíclico ou aromático (HDDI, DHDI e BDI, respectivamente) foram dissolvidos em solução de etanol a 75% e água Millipore a 25% em volume. Ceramic Primer (CP) foi utilizada como controle. Um silano experimental de metacrilato composto por 3-(Trimetoxisilil propilmetacrilato (TMPS), obtido como descrito, foi usado como controle. Sessenta placas retangulares de cerâmica (IPS e.max Press, Ivoclar Vivadent) foram fabricadas e separadas em 5 grupos (n = 12): Grupo 1 - silano experimental sem tio-uretano (CE); Grupo 2 - silano experimental com 2% em peso de HDDI (alifático); Grupo 3 - silano experimental com 2% em peso de BDI (aromático); Grupo 4 - silano experimental com 2% em peso de DHDI (cíclico) e Grupo 5 - Silano comercial Ceramic Primer. Antes da união, as superfícies cerâmicas foram condicionadas (20 s - 10% HF), uma camada dos diferentes silanos foi aplicada individualmente, seguida por adesivo Scotchbond Multi Purpose. Foram confeccionados quatro cilindros de cimento resinoso (RelyX Ultimate -1 mm de diâmetro) em cada superfície cerâmica, sendo dois cilindros testados após armazenamento a 37oC por 24 horas em água deionizada e outros dois após seis meses e testados para RUµC (1,0 mm / minuto) Os dados foram analisados por Análise de Variância dois fatores e teste de Tukey (? = 5%). As superfícies fraturadas foram analisadas para determinar os modos de falha. A RUµC para CP foi significativamente superior ao silano CE. DHDI, HDDI e BDI aumentaram a RUµC significativamente em relação ao CE após 24 horas ou seis meses. A RUµC diminuiu significativamente após 6 meses de armazenagem em água para todos os grupos. Os modos de falha foram predominantemente mistos. Os oligômeros de tio-uretano aumentaram a RUµC das amostras de cimento resinoso-cerâmica. O armazenamento após seis meses reduziu a RUµC para todos os silanos Abstract: The aim of this study was to evaluate the effect of silanes formulated with thio-urethane (TU) oligomers on the microshear bond strength (µSBS) of the lithium disilicate-based glass ceramics (IPS e.max Press) and resin cement after 24 h or six months of water storage. The experimental silanes containing 2 wt% of aliphatic, cyclic and aromatic thio-uretane oligomers (HDDI, DHDI and BDI, respectively) were dissolved in a solution of 75 vol% ethanol and 25 vol% Millipore water. Ceramic primer (CP) was used as the commercial control. An experimental methacrylate control silane composed of 3-(Trimethoxysilyl) propyl methacrylate (TMPS) was prepared, as described above. Sixty ceramic rectangular plates (IPS e.max Press, Ivoclar Vivadent) were fabricated and divided into 5 groups (n=12): Group 1 - experimental silane without thio-urethane (EC); Group 2 – experimental silane with 2 wt% of HDDI (Aliphatic); Group 3 - experimental silane with 2 wt% of BDI (Aromatic); Group 4 - experimental silane with 2 wt% of DHDI (Cyclic) and, Group 5 - commercial silane Ceramic Primer. Prior to bonding, ceramic surfaces were etched (20s – 10% HF), one layer of different silanes was individually applied, followed by unfilled resin Scotchbond Multi Purpose. Four resin cement cylinders (RelyX Ultimate -1 mm in diameter) were made on each ceramic surface with two cylinders being tested after storage at 37oC for 24 h in deionized water and the other two cylinders after six months and tested for µSBS (1.0 mm/min). Data were analyzed with two-way ANOVA/Tukey’s test (? = 5%). Fracture surfaces were analyzed to determine failure modes. The µSBS for CP was significantly higher than EC silane. DHDI, HDDI and BDI led to significantly higher µSBS than EC after 24 h or six months. µSBS decreased significantly after 6 months water storage for all groups. Failure modes were predominantly mixed. The use of thio-urethane oligomers was able to increase the µSBS of resin cement-ceramic specimens. The storage after six months reduced µSBS for all silanes. Key-words: silane, adhesion, resin cement, thio-urethane oligomers, ceramic, aging, bond strength Mestrado Materiais Dentários Mestre em Materiais Dentários FAPESP 2016/03576-9 CAPES 0878/2018 CNPQ 304493/20147
- Published
- 2020
36. Effect of experimental silanes formulated with different thio- urethanes on bond strength and adhesive properties of convencional and anatomical fiberglass post
- Author
-
Ramos, Roberta Araujo de Paula, 1994, Consani, Rafael Leonardo Xediek, 1974, Martins, Luís Roberto Marcondes, Oliveira, Pedro Cesar Garcia de, Universidade Estadual de Campinas. Faculdade de Odontologia de Piracicaba, Programa de Pós-Graduação em Clínica Odontológica, and UNIVERSIDADE ESTADUAL DE CAMPINAS
- Subjects
Bond strength ,Cimentos dentários ,Dental cements ,Pinos dentários ,Silano ,Silane ,Endodontia ,Dental pins ,Resistência de união ,Endodontics - Abstract
Orientador: Rafael Leonardo Xediek Consani Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba Resumo: O estudo in vitro avaliou o efeito de silanos experimentais à base de tio-uretanos na fixação de pinos de fibra de vidro convencional ou anatômico aos condutos radiculares por meio da resistência ao cisalhamento por extrusão, padrão de falha e infiltração marginal. Os silanos experimentais foram sintetizados a partir da combinação do tiol-pentaeritritol tetra-3-mercaptopropionato (PETMP) com isocianatos 1,6-hexanodiol-diissocioso (HDDI) (alifático), ou 4,4¿-diisocianato de diciclo-hexilmetano (HDMI) (cíclico), ou 1,3-bis (1- isocianato-1-metiletil) (BDI) (aromático). Após tratamento endodôntico convencional com pinos de fibra de vidro convencional ou anatômico, as raízes bovinas foram separadas nos grupos (n=10): G1: pino de fibra de vidro convencional + silano comercial RelyX Ceramic Primer (controle); G2: pino de fibra convencional + silano experimental HDDI; G3: pino de fibra convencional + silano experimental HDMI; G4- pino de fibra convencional + silano experimental BDI; G5- pino de fibra de vidro anatômico + silano comercial RelyX Ceramic Primer (controle); G6: pino de fibra anatômico + silano experimental HDDI; G7: pino de fibra anatômico + silano experimental HDMI; G8- pino de fibra anatômico + silano experimental BDI. Todos os grupos foram submetidos às ciclagens mecânica (1,2 x 106 ciclos) e térmica (500 ciclos). Obteve-se duas fatias com 1 mm de espessura de cada terço radicular (cervical, médio e apical), uma submetida ao teste de resistência ao cisalhamento por extrusão (MPa) e padrão de falha (%) e outra submetida à infiltração marginal por corante (%) azul de metileno a 2% por sete dias. Os dados de padrão de falha e microinfiltração foram analisados por meio das frequências absolutas e relativas, e a resistência da união adesiva por meio de análise exploratória com o programa R (Core Team, 2019) com nível de significância de 5%. Os resultados revelaram maior resistência adesiva nos grupos G3 e G4 em todos os terços radiculares e no G2 no terço médio quando comparados com o controle (p
- Published
- 2020
37. Avaliação in vitro da influência de cimentos endodônticos na resistência de união sobre estrutura dentinária da câmara pulpar de dentes restaurados imediatamente e mediatamente após obturação
- Author
-
Arantes, Paula Tamião, Gade Neto, Cicero Romão, Nóbrega, Leticia Maria Menezes, Aquino, Luana Maria Martins de, Silva Neto, Reinaldo Dias da, and Dametto, Fábio Roberto
- Subjects
CIENCIAS DA SAUDE::ODONTOLOGIA [CNPQ] ,Materiais restauradores ,Sistemas adesivos ,Cimentos endodônticos ,Resistência de união - Abstract
Este estudo teve por finalidade avaliar a influência dos cimentos endodônticos com um protocolo de irrigação na resistência de união sobre a estrutura dentinária das paredes da câmara pulpar de dentes bovinos restaurados imediatamente e após 7 dias do tratamento endodôntico. Foram avaliados os cimentos endodônticos: Cimento à base de resina epoxy (AH Plus – Dentsply, DeTrey, Konstanz- Alemanha) e Cimento de óxido de zinco e eugenol (Endofill – Dentsply Ind.com. LTDA – Brasil). Para a realização das restaurações foi utilizado o sistema adesivo Single Bond 2® (3M/ESPE) e a resina composta Z 350TM (3M/ESPE). 60 faces vestibulares da câmara pulpar de dentes bovinos foram distribuídos aleatoriamente em 4 grupos experimentais (G1-AHPlus Imediato; G2-AHPlus Mediato; G3-OZE Imediato; G4-OZE Mediato) e 2 controles (G5- NaOCl + EDTA Imediato e G6-NaOCl + EDTA Mediato). O protocolo de irrigação endodôntica deu-se através da imersão dos espécimes em solução de hipoclorito de sódio a 2.5% por 30 minutos e em EDTA 17% por 3 minutos. Os cimentos testados estiveram em contato com a parede dentinária pelo tempo de presa inicial, seguido de limpeza com algodão embebido em álcool 70% por 1 minuto. Os grupos experimentais de restauração mediata foram mantidos em estufa a 37ºC por 7 dias. Após o corte e a obtenção dos palitos de +/-1,0 mm² foi aplicado o teste de microtração na Máquina de Ensaios Universal e, em seguida, observados em microscópio óptico para classificação da fratura. Os valores da resistência de união foram submetidos ao teste não-paramétrico Wilcoxon-Mann-Whitney comparando dois a dois grupos a um nível de significância de 5%. Os resultados mostraram que o grupo G5 obteve menor valor de resistência de união, com diferença estatisticamente significativa (p
- Published
- 2019
38. Ozonized water as a dentin cleaning solution: antibacterial action and bond strength analysis
- Author
-
Laurindo, Brenda Matsunaga, Camilotti , Veridiana, Baeza , Lilian Cristiane, and Bocardi , Juliane Maria Bergamin
- Subjects
Bond strength ,Desinfetantes ,ODONTOLOGIA [CIENCIAS DA SAUDE] ,Antibacterial action ,Ação antibacteriana ,Resistência de união ,Disinfectants - Abstract
Submitted by Edineia Teixeira (edineia.teixeira@unioeste.br) on 2019-10-01T17:07:22Z No. of bitstreams: 2 Brenda_Laurindo_2019.pdf: 1571360 bytes, checksum: c3e6aee9376bf0e309622c888cb74a33 (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Made available in DSpace on 2019-10-01T17:07:22Z (GMT). No. of bitstreams: 2 Brenda_Laurindo_2019.pdf: 1571360 bytes, checksum: c3e6aee9376bf0e309622c888cb74a33 (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Previous issue date: 2019-04-08 Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES The objective of this work was to evaluate the antibacterial activity of ozonated water on the microorganisms Streptococcus mutans and Enterococcus faecalis and also to verify its influence on adhesive bond strength (RU), both conditions compared to 17% Trisodium EDTA; Sodium hypochlorite 2.5%; Chlorhexidine 2% and Saline. The antibacterial evaluation was carried out by the Bacterial Viability Test (TVB) on the microorganisms E. faecalis and S. mutans, in the times: T0 (soon after the bacterial inoculum placement); T10 (10min), T20 (20min), T30 (30min) and T60 (60min). For UK, 50 crowns of bovine teeth were divided and divided according to the cavity cleaning material. Three bulk fill resin cylinders were made for each bovine crown and the test was performed after 24 hours. The failure modes were evaluated with stereoscopic loupes with a 40x magnification. The data were analyzed statistically by the ANOVA test and Tukey's post-test with a significance level of p
- Published
- 2019
39. Resistência de União de um Sistema Universal à Superfície de Materiais Híbridos para CAD/CAM
- Published
- 2019
40. Resistência de União de um Sistema Universal à Superfície de Materiais Híbridos para CAD/CAM
- Published
- 2019
41. Resistência de União de um Sistema Universal à Superfície de Materiais Híbridos para CAD/CAM
- Published
- 2019
42. Resistência de União de um Sistema Universal à Superfície de Materiais Híbridos para CAD/CAM
- Published
- 2019
43. Resistência de União de um Sistema Universal à Superfície de Materiais Híbridos para CAD/CAM
- Published
- 2019
44. Aging methods for dentin bond strength tests
- Author
-
Brauner, Katielle Valente, Cenci, Tatiana Pereira, Moraes, Rafael Ratto de, and Cenci, Maximiliano Sérgio
- Subjects
CIENCIAS DA SAUDE::ODONTOLOGIA::MATERIAIS ODONTOLOGICOS [CNPQ] ,Envelhecimento ,Dentina ,Resistência de união - Abstract
Submitted by Alice Xavier (alice_liane@hotmail.com) on 2019-07-24T12:37:33Z No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Métodos de envelhecimento da interface adesiva para testes de adesão à dentina.pdf: 1943879 bytes, checksum: 6622bd34675338633419dd2bbfba241e (MD5) Made available in DSpace on 2019-07-24T12:37:33Z (GMT). No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Métodos de envelhecimento da interface adesiva para testes de adesão à dentina.pdf: 1943879 bytes, checksum: 6622bd34675338633419dd2bbfba241e (MD5) Previous issue date: 2019-02-13 Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES O objetivo deste trabalho foi avaliar o efeito da degradação da interface resinadentina, medida pela diminuição da resistência de união (RU) após diferentes métodos disponíveis para simulação de envelhecimento acelerado. O trabalho foi dividido em dois estudos: (1) uma revisão sistemática e meta-análise da literatura; e (2) um experimento in vitro. O primeiro estudo foi descrito de acordo com o PRISMA buscando avaliar se os diferentes métodos e protocolos de envelhecimento acelerado são efetivos na diminuição da resistência de união à dentina utilizando resina composta direta. Foi identificado que a ciclagem térmica teve efeito significativo na maioria dos protocolos utilizados para o envelhecimento da interface. Ciclagem mecânica e termomecânica, pressão pulpar, armazenamento de NaOCl e ciclagem térmica + armazenamento estático foram capazes de promover a diminuição da RU. O armazenamento em enzima só foi capaz de diminuir a RU em períodos de pelo menos 3 meses; e os protocolos de ciclagem de pH e desafio cariogênico avaliados não foram capazes de promover a diminuição da RU. Já o segundo estudo testou 5 das metodologias disponíveis em laboratório (termociclagem, ciclagem mecânica, ciclagem mecânica com Rub&Roll, desafio cariogênico e 5 semans de armazenamento em água) avaliando a resistência de uião à microtração. Para esse experimento foram utilizados dois tipos de adesivo (convencional e autocondicionante) e o grupo controle permaneceu em água (37ºC) por 24 horas. Foi observado que 14 dias de desafio cariogênico foram capazes de reduzir a RU do sistema adesivo convencional e a ciclagem mecânica do autocondicionante. Com esta tese podemos concluir que muitos métodos de envelhecimento acelerado podem ser efetivos na degradação da interface, porém diversos parâmetros devem ser considerados como tempo de envelhecimento, condições de armazenagem e material utilizado. The aim of this study was to evaluate the effect of degradation of resin-dentin interface, measured by the decrease of the bond strength (BS) after different available methods for simulation of accelerated aging. The work was divided into two studies: (1) a systematic review and meta-analysis of the literature; and (2) an in vitro experiment. The first study was described according to PRISMA to investigate whether the different accelerated aging methods and protocols are effective in reducing bond strength to dentin using direct composite resin. It was identified that the thermal cycling had a significant effect in most of the protocols used for the aging of the interface. Mechanical and thermomechanical cycling, pulpal pressure, NaOCl storage and thermal cycling + static storage were able to promote the decrease of BS. Enzyme storage was only able to decrease the BS in periods of at least 3 months; and the pH cycling and cariogenic challenge protocols evaluated were not able to promote the decrease of the BS. The second study tested 5 of the available methodologies in the laboratory (thermal cycling, mechanical cycling, mechanical cycling with Rub & Roll, cariogenic challenge and 5 weeks of storage in water) and evaluated microtensile bond strength. Two types of adhesive were used for this experiment (etch-and-rinse and self-etch) and the control group remained in water (37 C) for 24 hours. It was observed that 14 days of cariogenic challenge were able to reduce the BS of the etch-and-rinse adhesive system and the mechanical cycling of the self-etch. With this thesis we can conclude that many methods of accelerated aging can be effective in the degradation of interface, however, many parameters should be considered as aging time, storage conditions and material used.
- Published
- 2019
45. Performance of glulam beams produced with free-formaldehyde adhesive and underexploited rubber wood treated with preservatives solutions of chromated copper borate and pyrethroids
- Author
-
Soriano, Julio, 1967 and UNIVERSIDADE ESTADUAL DE CAMPINAS
- Subjects
Bond strength ,Flexural strength ,Madeira ,Artigo original ,Composite ,Resistência à flexão ,Wood ,Resistência de união - Abstract
The release of formaldehyde may cause serious human health problems. Free-formaldehyde adhesives is increasingly well regarded by industry, since some adhesives are effective in providing of good mechanical properties even when the object of study is treated wood. This study proposes to evaluate the properties of rubber wood treated with chromated copper borate (CCB) and pyrethroid to produce glued laminated (glulam) timber using different types of adhesives as a binder. The modulus of elasticity (MOE) of the rubber wood pieces was investigated and predicted in this study before the glulam beams production. Glulam beams were glued with: polyurethane (as a free-formaldehyde adhesive) and resorcinol-formaldehyde, in the presence or absence of preservative treatment. Each beam was composed by three wood pieces. In total, 30 glulam beams were produced, 15 for each type of adhesive (60 mm thickness, 60 mm wide and 1200 mm length). Rubber wood treated with CCB showed a significant increase in pH. The glulam beams with polyurethane did not present statistical difference from those produced with resorcinol-formaldehyde for MOE and MOR. The MOE values of the beams glued with polyurethane were 6124.66 and 5768.93 MPa for the treatment with CCB and pyrethroid, respectively. The glulam beams samples showed the same efficiency in shear strength test for both adhesives. The results indicate that polyurethane adhesive could be used as a possible alternative for glulam beams production Fechado
- Published
- 2019
46. Adhesion capacity of bioceramic and resin-based root canal sealer to root dentin: an integrative review
- Author
-
Mariane Floriano Lopes Santos Lacerda, Carolyne de Pinho Quintão, Caroline Felipe Magalhães Girelli, Sabrina Teixeira Pinto Costa, and Carolina Oliveira de Lima
- Subjects
Resistência de união ,Cimento endodôntico à base de resina epóxi ,Silicato tricálcico ,Web of science ,business.industry ,DENTAL MEDICINE (DENTISTRY) ,Bond strength ,Epoxy resin-based root canal sealer ,Tricalcium silicate ,Medicine ,Dentistry ,MEDICINA DENTÁRIA (ODONTOLOGIA) ,General Medicine ,business - Abstract
Aim: To compare the adhesion capacity of the bioceramic EndoSequence BC sealer and the AH Plus sealer through an integrative review. Methodology: The Medline/PubMed, Scopus, Web of Science and VHL online databases were used for the literature review. Eligibility criteria comprised articles available in full on the researched databases, in English, and content addressing Endosequence BC sealer adhesion compared to AH Plus sealer. Results: A total of 45 articles were found. After duplicate removal, 22 articles were selected. After reading the abstracts, full texts and applying the inclusion criteria, eight articles in total were included in the present study. Concerning the adhesion capacity of the tested cements, the AH Plus was reported as presenting better adhesion than the BC sealer in three articles, and less adhesion in two articles. Similar adherence strength was observed between groups in three studies. Conclusions: Based on the included studies, the AH Plus displays greater bond strength when compared to the BC Sealer. Objetivo: comparar a capacidade de adesão do cimento biocerâmico EndoSequence BC e do cimento resinoso AH Plus através de uma revisão integrativa. Material e Métodos: os bancos de dados online Medline/PubMed, Scopus, Web of Science e BVS foram utilizados para a revisão da literatura. Os critérios de elegibilidade incluíram artigos disponíveis na íntegra nas bases de dados pesquisadas, em inglês, e o conteúdo referente à adesão do cimento Endosequence BC sealer em comparação ao AH Plus. Resultados: foram encontrados 45 artigos. Após a remoção duplicada, 22 artigos foram selecionados. Após a leitura dos resumos, textos completos e aplicação dos critérios de inclusão, foram incluídos no total oito artigos. Em relação à capacidade de adesão dos cimentos testados, o AH Plus apresentou melhor adesão do que o cimento BC sealer em três artigos e menor adesão em dois artigos. Força de adesão semelhante foi observada entre os grupos em três estudos. Conclusões: com base nos estudos incluídos, o AH Plus apresenta maior resistência de união quando comparado ao BC Sealer
- Published
- 2020
- Full Text
- View/download PDF
47. Bond stregth and and fadigue failure load of a zirconia reinforced lithium silicate ceramic after adhesive cementation
- Author
-
Diniz, Vandeberg [UNESP], Universidade Estadual Paulista (Unesp), and Marinho, Renata Marques de Melo [UNESP]
- Subjects
Bond strength ,Lithium silicate ,Silicato de lítio ,Hydrofluoric acid ,Ácido fluorídrico ,Resistência de união - Abstract
Submitted by Vandeberg Diniz (vandebergdiniz@gmail.com) on 2019-02-07T13:30:49Z No. of bitstreams: 1 vandeberg diniz dissertacao.pdf: 3416351 bytes, checksum: 00c3d314bf8a0d50e1ebce91b42d4679 (MD5) Approved for entry into archive by Silvana Alvarez null (silvana@ict.unesp.br) on 2019-02-11T16:00:28Z (GMT) No. of bitstreams: 1 diniz_v_me_sjc.pdf: 3416351 bytes, checksum: 00c3d314bf8a0d50e1ebce91b42d4679 (MD5) Made available in DSpace on 2019-02-11T16:00:28Z (GMT). No. of bitstreams: 1 diniz_v_me_sjc.pdf: 3416351 bytes, checksum: 00c3d314bf8a0d50e1ebce91b42d4679 (MD5) Previous issue date: 2018-12-17 Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) No presente trabalho, avaliou-se o efeito de diferentes concentrações de ácido fluorídrico (5% e 10%), na resistência de união entre uma cerâmica de silicato de lítio reforçado por zircônia (sem cristalização adicional, com queima de glaze e com queima adicional de cristalização) e um cimento resinoso, com e sem envelhecimento. Avaliou-se também o comportamento em fadiga de uma cerâmica à base de silicato de lítio reforçado por zircônia (sem cristalização adicional, com de queima de glaze e com queima adicional de cristalização) cimentada adesivamente a um material análogo a dentina (NEMA G10), na ausência ou presença de envelhecimento. Para o teste de microtração os blocos cerâmicos de silicato de lítio reforçado por zircônia foram cortados em blocos menores e divididos aleatoriamente em 12 grupos (N = 72; n = 6). No teste de fadiga os espécimes foram em formato de discos (diâmetro de 12 mm e espessura de 1,2 mm) cimentados a discos de resina epoxi Nema G10 (diâmetro de 12mm e espessura de 2,3mm), divididos em 6 grupos (N = 120; n = 20) e submetidos a ensaio de fadiga pelo método da escada (100.000 ciclos, 20 Hertz de frequência). Os dados resistência de união (MPa) e fadiga (N) foram submetidos à ANOVA 2-fatores, e respectivamente submetidos aos testes de Tukey e Bonferroni (p
- Published
- 2018
48. Correlation of permeability with bond strenght in deproteinized human dentin using laser and calcium phosphate treatments
- Author
-
Andrade, Danilo de Souza [UNESP], Universidade Estadual Paulista (Unesp), Pucci, César Rogério [UNESP], and Feitosa, Fernanda Alves
- Subjects
Dentin Permeability ,YAG Laser [Nd] ,Permeabilidade da Dentina ,Bond Strenght ,Sodium Hypochlorite ,Calcium Phosphate ,Hipoclorito de Sódio ,Resistência de União ,Fosfato de Cálcio ,YAG [Laser de Nd] - Abstract
Submitted by Danilo de Souza Andrade (danilodesouzaandrade@outlook.com) on 2019-01-28T13:40:02Z No. of bitstreams: 1 Dissertacao Mestrado DANILO DE SOUZA ANDRADE-merged.pdf: 3983811 bytes, checksum: 193d69b1e38841294cf5c39eb0ffdea7 (MD5) Approved for entry into archive by Silvana Alvarez null (silvana@ict.unesp.br) on 2019-01-30T18:02:17Z (GMT) No. of bitstreams: 2 andrade_ds_me_sjc_par.pdf: 503405 bytes, checksum: ff73fbcf946c08ae7449e57c0931a65b (MD5) andrade_ds_me_sjc_int.pdf: 3983811 bytes, checksum: 193d69b1e38841294cf5c39eb0ffdea7 (MD5) Made available in DSpace on 2019-01-30T18:02:17Z (GMT). No. of bitstreams: 2 andrade_ds_me_sjc_par.pdf: 503405 bytes, checksum: ff73fbcf946c08ae7449e57c0931a65b (MD5) andrade_ds_me_sjc_int.pdf: 3983811 bytes, checksum: 193d69b1e38841294cf5c39eb0ffdea7 (MD5) Previous issue date: 2018-12-14 Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) As restaurações a base de materiais resinosos tiveram um grande desenvolvimento, entretanto a durabilidade da interface adesiva ao substrato dental ainda é comprometida pela permeabilidade dentinária e pela degradação da camada hibrida. O objetivo desse estudo foi avaliar, in vitro, tratamentos que reduzem a permeabilidade dentinária, como aplicação de produto dessensibilizante à base de fosfato de cálcio e processo assistido a laser, e correlacionar essa redução de permeabilidade com a resistência de união a dentina. Sessenta discos de dentina de molares humanos com 6 mm de diâmetro e 1,5 mm de altura foram utilizados. Foi realizado desproteinização na superfície dentinária oclusal de todas as amostras. As amostras foram divididas em seis grupos (n=10) conforme os tratamentos sendo: A – Adesivo (Single Bond Universal – 3M ESPE); LA – Laser de Nd:YAG + Adesivo; AL - Adesivo + Laser Nd:YAG; FA – Fosfato de Cálcio + Adesivo; FLA – Fosfato de Cálcio + Laser Nd:YAG + Adesivo e FAL – Fosfato de Cálcio + Adesivo + Laser Nd:YAG. O percentual das permeabilidades inicial e final (após tratamento) foi calculado a partir da permeabilidade máxima. Os grupos foram comparados em cada momento da avalição da permeabilidade (inicial e final). Para o teste de resistência de união (RU) as amostras foram restauradas com resina composta (Z350 – 3M ESPE) e submetidas ao envelhecimento termomecânico (5.000 ciclos térmicos e 120.000 mecânicos), posteriormente foram confeccionados palitos para o teste de microtração. Os resultados para a permeabilidade dentinária e desvio padrão foram (médias percentuais %): iniciais A: 63,18 (±15,82); FA: 72,87 (±17,48); LA: 78,42 (±15,92); FLA: 72,64 (±24,28); AL: 74,96 (±16,86) ; FAL: 71,60 (±15,33) e as médias percentuais após os tratamentos: A: 29,99 (±16,38); FA: 34,42 (±18,60); LA: 35,13 (±20,61); FLA: 26,70 (±11,44); AL: 20,20 (±6,32) e FAL: 23,85 (±12,30). Os resultados e o desvio padrão para o teste de RU (em Mpa) foram: A 35,28 (±4,18); FA 32,17(±3,10); LA 39,19 (±4,58); FLA 36,06 (±2,75); AL 34,34 (±3,63) e FAL 35,14 (±2,40). Os dados foram submetidos ao teste de ANOVA, para a permeabilidade, observou-se uma redução estatisticamente significante para todos os tratamentos (p=0), no entanto não foram observadas diferenças na redução da permeabilidade entre os tratamentos (p=0,318125), para a RU a presença de fosfato não demonstrou diferença estatisticamente significante (p>0,05), no entanto para o fator tratamento houve diferença entre os grupos (p 0.05), however for the treatment factor there was difference between the groups (p
- Published
- 2018
49. Different hydrofluoric acid concentrations: effect on adhesion and fatigue behavior of a lithium disilicate ceramic
- Author
-
Prochnow, Catina, Valandro, Luiz Felipe, Pereira, Gabriel Kalil Rocha, Bonfante, Estevam Augusto, Spazzin, Aloísio Oro, Aurélio, Iana Lamadrid, and May, Liliana Gressler
- Subjects
Bond strength ,Rugosidade ,Atomic force ,CIENCIAS DA SAUDE::ODONTOLOGIA [CNPQ] ,Microshear ,Ângulo de contato ,Microcisalhamento ,Força atômica ,Roughness ,Ácido fluorídrico ,CAD/CAM ,Fadiga ,Adesão ,Cyclic load ,Carregamento cíclico dissilicato de lítio ,Adhesion ,Contact angle ,Hydrofluoric acid ,Lithium disilicate ,Fatigue ,Resistência de união - Abstract
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES The studies compound the present thesis. Firstly, the effect of different hydrofluoric acid (HF) concentrations (1%, 3%, 5% and 10%) on the microshear bond strength between a lithium disilicate ceramic and a resin cement was evaluated. Samples (12×14×2mm) of lithium disilicate were etched with the respective HF concentrations, silanized, and resin cement cylinders (Ø=0.72mm) were built up over the surfaces. A half of the samples was tested after 24h, and the other half was submitted to aging (150 days + 12,000 thermocycles – 5° and 55°C) previously to testing. Contact angle, atomic force and surface topography analysis were performed. On the “baseline” condition, HF3=HF5=HF10 (13.9–15.9MPa) (p>.05), and HF1HF1). The groups HF3, HF5, and HF10 presented lower contact angle values (7.8–10.4°). Higher HF concentrations promoted higher topographic alterations and consequently, rougher surfaces. In terms of adhesion, concentrations of 3%, 5% and 10% seem to be adequate for etching lithium disilicate. Secondly, the effect of different HF concentrations on the cyclic load-to-failure of lithium disilicate discs luted to a dentin analogue material was investigated. Ceramic discs (Ø=10mm; thickness=1.5mm) and of a dentin analogue material (G10; Ø=10 mm, thickness=2mm) were produced. With exception of the control group (CRTL), the ceramic discs were etched (HF3), (HF5) or (HF10) and later silanized, meanwhile the G10 discs received an adhesive primer application. After the adhesive luting, the cyclic load-to-failure (500,000 cycles, 20Hz, initial load=720N, step size=70N) was obtained by the staircase method, under water. A stainless-steel piston (Ø=40mm) applied the load in the center of the samples. Fractographic and topographic analysis were performed. Intermediate HF concentrations (3% and 5%) presented higher cyclic load-to-failure values, and the control group (non-etched) presented the worst behavior under fatigue [HF3(1355.0) = HF5(1335.0) > HF10(1175.0) > CTRL(965.0)]. All failures observed were radial cracks starting from the cementation surface. Lastly, the effect of different HF concentrations was evaluated on the cyclic load-to-failure of monolithic lithium disilicate restorations machined by CAD-CAM adhesively luted to simplified prosthetic preparations (G10). The staircase method was used for the tests following the same test assembly and experimental design of the previous study. Topographic, fractographic and fractal dimension analyses were performed. There was no statistical difference among the tested groups [CTRL(805.00) = HF3(781.25) = HF5(755.00) = HF10(833.75)]. Despite the fractal dimension and surface topography analyses have shown complex surfaces to HF3 and HF10, the topographic path created by machining was overweight on the lithium disilicate crowns. All failures found were radial cracks started from the luted surface. Based on the findings of the present thesis, in terms of adhesion and fatigue behavior, the ceramic tested can be etched with 3 and 5% HF. Três estudos compõe a presente tese. Primeiramente, o efeito de diferentes concentrações de ácido fluorídrico (HF; 1%, 3%, 5% e 10%) na resistência de união ao microcisalhamento entre uma cerâmica de dissilicato de lítio e um cimento resinoso foi avaliado. Amostras (12×14×2mm) de dissilicato de lítio foram condicionadas com as respectivas concentrações de ácido, silanizadas e cilindros de cimento resinoso (Ø=0.72mm) foram construídos sobre as superfícies. Metade das amostras foi testada após 24 h, e a outra metade foi submetida ao envelhecimento (150 dias + 12.000 ciclos térmicos – 5° e 55°C) prévio ao ensaio. Ângulo de contato, microscopia de força atômica e topografia de superfície foram realizadas. Na condição inicial, HF3=HF5=HF10 (13.9–15.9MPa) (p>.05), e HF1HF1). Os grupos HF3, HF5 e HF10 apresentaram menores valores de ângulo de contato (7.8–10.4°). Maiores concentrações de HF promoveram maiores alterações topográficas e consequentemente, superfícies mais rugosas. Em termos de adesão, concentrações de 3%, 5% e 10% parecem ser adequadas para o condicionamento do dissilicato de lítio. Segundamente, o efeito de diferentes concentrações de HF na carga cíclica para falha de discos de dissilicato de lítio cimentados a um material análogo de dentina foi investigado. Discos cerâmicos (Ø=10mm; espessura=1.5mm) e discos de um material análogo de dentina (G10; Ø=10 mm, espessura=2mm) foram produzidos. A exceção do controle (CTRL), os discos cerâmicos foram condicionados (HF3), (HF5) ou (HF10) e posteriormente silanizados, enquanto os discos de G10 receberam a aplicação de um primer adesivo. Após a cimentação adesiva, a carga cíclica para falha (500.000 ciclos, 20Hz, carga inicial=720N, incremento=70N) foi obtida através do método da escada, na presença de água. Um pistão de aço hemisférico (Ø=40mm) aplicou a carga no centro dos espécimes. Análise fractográfica e topográfica foram realizadas. Concentrações intermediárias de ácido fluorídrico (3% e 5%) apresentaram maiores valores de carga cíclica para falha, e o grupo controle (não condicionado) apresentou o pior comportamento em fadiga [HF3(1355.0) = HF5(1335.0) > HF10(1175.0) > CTRL(965.0)]. Todas as falhas observadas foram trincas radiais iniciadas a partir da superfície de cimentação. Por fim, o efeito de diferentes concentrações de HF foi avaliado na carga cíclica para falha de restaurações monolíticas de dissilicato de lítio usinadas pelo sistema CAD-CAM adesivamente cimentadas a preparos protéticos simplificados (G10). O método da escada foi utilizado para os ensaios de fadiga utilizando a mesma configuração de teste e delineamento experimental do estudo anterior. Análises topográfica, fractográfica e de dimensão fractal foram realizadas. Não houve diferença estatística entre os grupos testados [CTRL(805.00) = HF3(781.25) = HF5(755.00) = HF10(833.75)]. Apesar das análises de dimensão fractal e topografia de superfície terem mostrado superfícies mais complexas para HF3 e HF10, o padrão topográfico criado pela usinagem foi preponderante nas coroas de dissilicato de lítio. Todas as falhas encontradas foram trincas radiais iniciadas a partir da superfície de cimentação. Baseado nos resultados da presente tese, em termos de adesão e comportamento em fadiga, a cerâmica testada pode ser condicionada com HF 3% e 5%.
- Published
- 2018
50. Effect of air-abrasion with a new silica-coated alumina based material of different concentrations on the adhesion and mechanical properties of Y-TZP
- Author
-
Rodrigues, Ana Carolina Cadore, Valandro, Luiz Felipe, Pereira, Gabriel Kalil Rocha, Venturini, Andressa Borin, and Fraga, Sara
- Subjects
Bond strength ,Flexural strength ,Concentração de sílica ,Zircônia policristalina parcialmente estabilizada por óxido de ítrio ,Fadiga ,Tratamento de superfície ,CIENCIAS DA SAUDE::ODONTOLOGIA [CNPQ] ,Surface treatment ,Zirconium oxide partially stabilized by yttrium ,Resistência à flexão ,Silica concentration ,Fatigue ,Resistência de união - Abstract
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES This study is formatted into two parts: the aim of the first study was to evaluate a new approach (Sol-gel approach) to obtain an alternative material for air-abrasion (silica-coated with different concentrations aluminum oxide) on the bond strength with and without long-term aging between resin cement and a Y-TZP ceramic, considering different silica concentrations. Y-TZP ceramic specimens (7 × 6.3 × 2 mm3) were made and embedded in PVC molds using chemically activated acrylic resin. The specimens were allocated into 8 groups (n = 20) considering two factors: surface treatment (SiC: silica-coated aluminum oxide particles; AlOx: aluminum oxide particles; 7%Si: experimental material of silica-coated aluminum oxide particles (composed of 93% alumina and 7% silica); 20%Si experimental material of silica-coated aluminum oxide particles (composed of 80% alumina and 20% silica)) and aging (baseline: 24 hours at 37°C in a steam chamber; or aging with 90 days in a steam chamber + 12,000 cycles, 5-55ºC). The air-abrasion was executed for 10 sec at 1 cm distance from the devices tip with oscillatory movements at a pressure of 2.8 bar. The silane coupling agent Monobond Plus was applied on the ceramic surface and resin composite cylinders were made and cemented with Multilink Automix on Y-TZP ceramic and light cured. The shear test was performed using a wire loop (Ø = 0.5 mm). In baseline condition all groups presented similar bond strength values. After aging, the groups SiC and 7%Si remained similar to their counterpart baseline groups, while the groups AlOx and 20% presented a decrease on the bond strength values. A great amount of silica concentration of 20% was not capable to promote stable adhesion to resin cement after aging and it was similar to the AlOx group. However, 7%Si and SiC groups were similar and presented a better performance after aging. The second study evaluated the effect of the alternative material for air-abrasion on the superficial characteristics (topography and roughness), structural stability (t-m phase transformation) and fatigue performance (biaxial flexure fatigue strength) of Y-TZP ceramic, considering two different silica concentrations. Disc-shaped specimens were manufactured according to ISO 6872:2015 and allocated into 4 groups (n = 30) according to the surface treatment: SiC; AlOx; 7%Si; 20%Si. The air-abrasion was executed following the same protocol previously descripted on study 1. The biaxial flexural fatigue strength test was performed using the staircase method. The 7%Si group presented the highest fatigue strength values and it was similar to the SiC group, while the 20%Si group presented the worst fatigue behavior and it was similar to the AlOx group. The increase on silica-coating concentration did not promoted a gentle air-abrasion protocol, and 7%Si group promoted a higher fatigue performance compared to 20%Si. Este trabalho está formatado em dois estudos: o objetivo do estudo 1 foi avaliar uma nova abordagem (método Sol-gel) para obtenção de um material alternativo para jateamento (óxido de alumínio revestido por diferentes concentrações de sílica) na resistência de união com e sem envelhecimento entre uma cerâmica Y-TZP e cimento resinoso, considerando diferentes concentrações de sílica. Espécimes de cerâmica Y-TZP (7 × 6.3 × 2 mm3) foram confeccionados e embutidos em moldes de PVC com resina acrílica autopolimerizável. Os espécimes foram alocados em 8 grupos (n=20) considerando dois fatores: tratamento de superfície (SiC: partículas de óxido de alumínio revestidas por sílica; AlOx: partículas de óxido de alumínio; 7%Si: material experimental de partículas de óxido de alumínio revestidas por sílica (composto por 93% alumina e 7% sílica); 20%Si: material experimental de partículas de óxido de alumínio revestidas por sílica (composto por 80% alumina e 20% sílica)) e envelhecimento (baseline: 24 horas em estufa a 37°C; ou envelhecido: 90 dias em estufa + 12,000 ciclos, 5-55ºC). O jateamento foi executado com movimentos oscilatórios por 10 segundos a 1 cm de distânica e pressão de 2.8 bar. O silano Monobond Plus foi aplicado na superfície da cerâmica e cilindros de resina composta foram confeccionados e cimentados com Multilink Automix na superfície da Y-TZP e fotopolimerizados. O teste de cisalhamento foi realizado com fio (Ø= 0,5 mm). Na condição baseline todos os grupos apresentaram valores similares de resistência de união. Após envelhecimento, os grupos SiC e 7%Si permaneceram similares aos seus respectivos grupos na condição baseline, enquanto os grupos AlOx e 20%Si apresentaram redução nos valores de resistência de união. O aumento na concentração de sílica de 20% não foi capaz de estabilizar a adesão ao cimento resinoso após envelhecimento e foi similar ao grupo AlOx, entretanto os grupos 7%Si e SiC foram similares e apresentaram melhor desempenho após envelhecimento. O estudo 2 avaliou o efeito do material alternativo para jateamento nas características de superfície (análise topográfica e rugosidade), estabilidade estrutural (transformação de fase t→m) e comportamento à fadiga (resistência à flexão biaxial) da cerâmica Y-TZP, considerando duas diferentes concentrações de sílica. Discos de cerâmica Y-TZP foram confeccionados conforme a norma ISO 6872:2015 e alocados em 4 grupos (n=30) de acordo com o tratamento de superfície: SiC; AlOx; 7%Si; 20%Si. Os espécimes foram jateados segundo mesmo protocolo descrito para o estudo 1 e o teste de resistência a flexão biaxial foi realizado em fadiga utilizando o método de escada (staircase). O grupo 7%Si apresentou os maiores valores de resistência à fadiga e foi similar ao grupo SiC, enquanto o grupo 20%Si apresentou o pior comportamento a fadiga e foi similar ao grupo AlOx. O aumento na concentração de sílica não promoveu um protocolo mais suave de jateamento, sendo que o grupo 7%Si promoveu um melhor desempenho à fadiga em comparação ao 20%Si.
- Published
- 2018
Catalog
Discovery Service for Jio Institute Digital Library
For full access to our library's resources, please sign in.