9 results on '"Rodríguez Gutiérrez, Gerardo"'
Search Results
2. Monitoring of a rehabilitated building in soft soil in Mexico and structural response to the September 2017 earthquakes: Part 1: structural health monitoring system
- Author
-
Murià-Vila, David, primary, Aldama-Sánchez, Baruo Daniel, additional, García-Illescas, Miguel Ángel, additional, and Rodríguez Gutiérrez, Gerardo, additional
- Published
- 2021
- Full Text
- View/download PDF
3. Distributed Optical Fiber for laboratory and field testing in concrete structures
- Author
-
Rodríguez Gutiérrez, Gerardo, Casas Rius, Joan Ramon, Barrias, Antonio Jose de Sousa, Villalba Herrero, Sergi, Universitat Politècnica de Catalunya. Departament d'Enginyeria Civil i Ambiental, Universitat Politècnica de Catalunya. Departament d'Enginyeria de Projectes i de la Construcció, Universitat Politècnica de Catalunya. EC - Enginyeria de la Construcció, and Universitat Politècnica de Catalunya. GRIC - Grup de Recerca i Innovació de la Construcció
- Subjects
Structural health monitoring ,Concrete construction ,Crack detection ,Ddistributed optical fiber sensors ,Monitoring system ,Enginyeria civil::Materials i estructures::Materials i estructures de formigó [Àrees temàtiques de la UPC] ,Detectors de fibra òptica ,Concrete structures ,Construcció en formigó ,Optical fiber detectors - Abstract
This paper outlines the principal results of laboratory and field testing in concrete structures to show the capabilities of distributed optical fiber sensors (DOFS) in their application to monitoring concrete structures. In the first part of this paper, a methodology to obtain the mean shear crack width in concrete beams is proposed. This methodology is based on the laboratory experimental data obtained by a DOFS bonded to the surface of two pre-stressed partial concrete (PPC) beams subjected to shear test with increasing levels of load. The results show the feasibility of the proposed method in calculating the shear crack width when compared to the results from traditional instrumentation. In the second part of the paper, a monitoring process by DOFS on a real world structure is described. The principal results of the enlargement of a pre-stressed concrete bridge are presented. The versatility and easy installation of DOFS compared with traditional monitoring systems is an important characteristic to consider in its application when monitoring real world structures. The DOFS used in this study provide continuous (in space) strain data along the optical fiber with high spatial resolution in the order of millimeters. This study verifies that the OBR technique is applicable in real conditions and confirms the high accuracy inherent to the optical fiber technology. The use of the OBR technique is not only able to detect appearing cracks, but also to perform a global structural behavior monitoring. For this reason, this technique is an important alternative to cover the limitations (number of points interrogated) of the discrete sensors such as strain gauges or LVDT´s, with which only local data is obtained.
- Published
- 2020
4. Distributed Optical Fiber for laboratory and field testing in concrete structures
- Author
-
Universitat Politècnica de Catalunya. Departament d'Enginyeria Civil i Ambiental, Universitat Politècnica de Catalunya. Departament d'Enginyeria de Projectes i de la Construcció, Universitat Politècnica de Catalunya. EC - Enginyeria de la Construcció, Universitat Politècnica de Catalunya. GRIC - Grup de Recerca i Innovació de la Construcció, Rodríguez Gutiérrez, Gerardo, Casas Rius, Joan Ramon, Barrias, Antonio Jose de Sousa, Villalba Herrero, Sergi, Universitat Politècnica de Catalunya. Departament d'Enginyeria Civil i Ambiental, Universitat Politècnica de Catalunya. Departament d'Enginyeria de Projectes i de la Construcció, Universitat Politècnica de Catalunya. EC - Enginyeria de la Construcció, Universitat Politècnica de Catalunya. GRIC - Grup de Recerca i Innovació de la Construcció, Rodríguez Gutiérrez, Gerardo, Casas Rius, Joan Ramon, Barrias, Antonio Jose de Sousa, and Villalba Herrero, Sergi
- Abstract
This paper outlines the principal results of laboratory and field testing in concrete structures to show the capabilities of distributed optical fiber sensors (DOFS) in their application to monitoring concrete structures. In the first part of this paper, a methodology to obtain the mean shear crack width in concrete beams is proposed. This methodology is based on the laboratory experimental data obtained by a DOFS bonded to the surface of two pre-stressed partial concrete (PPC) beams subjected to shear test with increasing levels of load. The results show the feasibility of the proposed method in calculating the shear crack width when compared to the results from traditional instrumentation. In the second part of the paper, a monitoring process by DOFS on a real world structure is described. The principal results of the enlargement of a pre-stressed concrete bridge are presented. The versatility and easy installation of DOFS compared with traditional monitoring systems is an important characteristic to consider in its application when monitoring real world structures. The DOFS used in this study provide continuous (in space) strain data along the optical fiber with high spatial resolution in the order of millimeters. This study verifies that the OBR technique is applicable in real conditions and confirms the high accuracy inherent to the optical fiber technology. The use of the OBR technique is not only able to detect appearing cracks, but also to perform a global structural behavior monitoring. For this reason, this technique is an important alternative to cover the limitations (number of points interrogated) of the discrete sensors such as strain gauges or LVDT´s, with which only local data is obtained., Postprint (published version)
- Published
- 2020
5. Monitorización estructural con sensores de fibra óptica distribuida: aplicaciones en estructuras de hormigón
- Author
-
Rodríguez Gutiérrez, Gerardo, Casas Rius, Joan Ramon|||0000-0003-4473-4308, Universitat Politècnica de Catalunya. Departament d'Enginyeria Civil i Ambiental, and Universitat Politècnica de Catalunya. EC - Enginyeria de la Construcció
- Subjects
Monitorització de salut estructural ,Structural health monitoring ,Enginyeria civil::Materials i estructures [Àrees temàtiques de la UPC] ,Detectors de fibra òptica ,Optical fiber detectors - Abstract
Se presenta el uso de un reflectómetro óptico de retrodispersión denominado sistema OBR (Optical Backscattered Reflectometer por sus siglas en inglés), como una herramienta de monitorización de la salud estructural (MSE) en estructuras de hormigón, las cuales pueden presentar fisuras incluso en condiciones de servicio. La principal característica del sistema OBR es su gran sensibilidad y alta resolución espacial a través del uso de un cable de fibra óptica como sensor y que se denomina sensor de fibra óptica distribuida (SFOD). Lo anterior, produce registros de deformación en los cuales se puede identificar y localizar la presencia de fisuras. El sistema OBR se aplica en el estudio de vigas de hormigón parcialmente pretensado. Estas vigas fueron instrumentadas tanto en forma convencional con sensores discretos, como con un SFOD adherido a la superficie. También se lleva a cabo la aplicación del sistema OBR de una estructura en condiciones reales. En esta aplicación, los efectos de temperatura son un factor importante a tomar en cuenta para una interpretación correcta de los datos obtenidos.
- Published
- 2019
6. Monitorización estructural con sensores de fibra óptica distribuida: aplicaciones en estructuras de hormigón
- Author
-
Universitat Politècnica de Catalunya. Departament d'Enginyeria Civil i Ambiental, Universitat Politècnica de Catalunya. EC - Enginyeria de la Construcció, Rodríguez Gutiérrez, Gerardo, Casas Rius, Joan Ramon, Universitat Politècnica de Catalunya. Departament d'Enginyeria Civil i Ambiental, Universitat Politècnica de Catalunya. EC - Enginyeria de la Construcció, Rodríguez Gutiérrez, Gerardo, and Casas Rius, Joan Ramon
- Abstract
Se presenta el uso de un reflectómetro óptico de retrodispersión denominado sistema OBR (Optical Backscattered Reflectometer por sus siglas en inglés), como una herramienta de monitorización de la salud estructural (MSE) en estructuras de hormigón, las cuales pueden presentar fisuras incluso en condiciones de servicio. La principal característica del sistema OBR es su gran sensibilidad y alta resolución espacial a través del uso de un cable de fibra óptica como sensor y que se denomina sensor de fibra óptica distribuida (SFOD). Lo anterior, produce registros de deformación en los cuales se puede identificar y localizar la presencia de fisuras. El sistema OBR se aplica en el estudio de vigas de hormigón parcialmente pretensado. Estas vigas fueron instrumentadas tanto en forma convencional con sensores discretos, como con un SFOD adherido a la superficie. También se lleva a cabo la aplicación del sistema OBR de una estructura en condiciones reales. En esta aplicación, los efectos de temperatura son un factor importante a tomar en cuenta para una interpretación correcta de los datos obtenidos., Postprint (published version)
- Published
- 2019
7. Shear crack pattern identification in concrete elements via distributed optical fibre grid
- Author
-
Universitat Politècnica de Catalunya. Departament d'Enginyeria Civil i Ambiental, Universitat Politècnica de Catalunya. Departament d'Enginyeria de Projectes i de la Construcció, Universitat Politècnica de Catalunya. EC - Enginyeria de la Construcció, Universitat Politècnica de Catalunya. GRIC - Grup de Recerca i Innovació de la Construcció, Rodríguez Gutiérrez, Gerardo, Casas Rius, Joan Ramon, Villalba Herrero, Sergi, Universitat Politècnica de Catalunya. Departament d'Enginyeria Civil i Ambiental, Universitat Politècnica de Catalunya. Departament d'Enginyeria de Projectes i de la Construcció, Universitat Politècnica de Catalunya. EC - Enginyeria de la Construcció, Universitat Politècnica de Catalunya. GRIC - Grup de Recerca i Innovació de la Construcció, Rodríguez Gutiérrez, Gerardo, Casas Rius, Joan Ramon, and Villalba Herrero, Sergi
- Abstract
This is an Accepted Manuscript of an article published by Taylor & Francis Group in "Structure and infrastructure engineering: maintenance, management, life-cycle design and performance" on 2019, available online at: http://www.tandfonline.com/10.1080/15732479.2019.1640256, An experimental methodology to obtain the shear cracking pattern in concrete elements is presented. The method is based on the use of Distributed Optical Fiber Sensors (DOFS) connected to an Optical Backscattered Reflectometer (OBR). Using this OBR system and a 2D grid conformed by one or two DOFS, the crack patterns of three partially pre-stressed concrete (PPC) beams subjected experimentally to shear failure, were obtained for increasing level of load. The 2D distributed fiber optic sensoring mesh was formed by attaching the fiber to the shear span of each beam using an epoxy adhesive. The importance of a correct DOFS attaching procedure to the concrete surface to obtain accurate results is described, and the principal advantages of DOFS to complement the use of discrete sensors in concrete experimental shear tests are shown. The proposed technique is a powerful tool to be implemented in the structural health monitoring in shear of concrete structures, where the variable inclined cracks are difficult to monitor by other experimental techniques using discrete sensors., Peer Reviewed, Postprint (author's final draft)
- Published
- 2019
8. Monitorización de estructuras de hormigón mediante sensores de fibra óptica distribuida
- Author
-
Rodríguez Gutiérrez, Gerardo, Casas Rius, Joan Ramon, Villalba Herrero, Sergi, and Universitat Politècnica de Catalunya. Departament d'Enginyeria Civil i Ambiental
- Subjects
Enginyeria civil [Àrees temàtiques de la UPC] ,Enginyeria d'estructures ,Reflexió (Òptica) ,Fibres òptiques - Abstract
This doctoral thesis presents the use of an opto-electronic system so-called OBR (Optical Backscattered Reflectometer) as an alternative of measurement in structural health monitoring (SHM) processes in concrete structures, which may present cracks even for service loads. The main feature of the OBR system is its great sensitivity and high spatial resolution through the use of an optical fiber cable as a sensor, which is called the distributed optical fiber sensor (DOFS). Thanks to that, it becomes possible to obtain strain records where the presence of cracks can be identified and localized. Thus, the experience of an earlier application is first taken up and a method of calculating average crack width in concrete structures subjected to bending is proposed and it is based on information from the strain records obtained with the OBR system. Afterwards, the OBR system is applied to the study of three partially pre-stressed concrete (PPC) beams of 8 m in length and subjected to shear stress. These beams were instrumented both in conventional form with discrete sensors, and with a DOFS adhered to the surface. Based on the experimental results obtained, the capacity of the OBR system to monitor concrete structures subjected to shear is evaluated, and a method is proposed to detect, locate and subsequently quantify the average shear crack width. One of the three beams tested to shear and already with the presence of cracks along its entire length, is tested to flexion. In this test it is evaluated the system ability to detect the presence of existing cracks, and the appearance of new cracks. Once the main cracks have been detected and localized, the proposed method of calculating average crack width is again applied and the results checked. Finally, the application of the OBR system to a real structure is carried out. The above consisted in the monitoring over almost eight months of the process of enlarging a two-span pre-stressed concrete bridge with a total length of 86 m. In this application, the effects of temperature were an important factor and their correction was taken into account for a correct interpretation of the obtained data. Finally, based on what was observed through the information obtained in each of the previous cases, some conclusions are established regarding the advantages and disadvantages of this type of opto-electronic measurement systems based on the use of DOFS in the SHM of concrete structures. The main conclusion is that the method proposed in this thesis achieves a very satisfactory and promising results regarding the detection, localization and quantification of cracking both in bending and shear in concrete structures in the range of normal service loads., En esta tesis doctoral se presenta el uso de un reflectómetro óptico de retrodispersión denominado sistema OBR (optical backscattered reflectometer por sus siglas en inglés), como una herramienta de monitorización de la salud estructural (MSE) en estructuras de hormigón, las cuales pueden presentar fisuras incluso en condiciones de servicio. La principal característica del sistema OBR es su gran sensibilidad y alta resolución espacial a través del uso de un cable de fibra óptica como sensor y que se denomina sensor de fibra óptica distribuida (SFOD). Lo anterior, produce registros de deformación en los cuales se puede identificar y localizar la presencia de fisuras. Así, en primer lugar se retoma la experiencia de una aplicación anterior, y se propone un método del cálculo de ancho de fisura promedio en estructuras de hormigón sujetas básicamente a flexión, y que se basa en la información de los registros de deformación que se obtienen con el sistema OBR. A continuación, el sistema OBR se aplica en el estudio de tres vigas de hormigón parcialmente pretensado (HPP) de 8 m de longitud y sujetas a esfuerzo cortante. Estas vigas fueron instrumentadas tanto en forma convencional con sensores discretos, como con un SFOD adherido a la superficie. Con base en los resultados experimentales obtenidos, se evalúa la capacidad del sistema OBR para monitorizar estructuras de hormigón sujetas a cortante, y se propone un método para detectar, localizar y posteriormente cuantificar el ancho de fisura promedio a cortante. Posteriormente, una de las tres vigas ensayadas a cortante y ya con la presencia de fisuras a lo largo de toda su longitud, es ensaya a flexión. En esta viga se evalúa la capacidad del sistema para detectar la presencia de fisuras ya existentes, y la aparición de nuevas fisuras. Una vez detectadas y localizadas las principales fisuras por flexión, se aplica el método del cálculo del ancho de fisura propuesto y se evalúan sus resultados. También se lleva a cabo la aplicación del sistema OBR de una estructura en condiciones reales. Lo anterior consistió en la monitorización a lo largo de casi ocho meses, del proceso ampliación de un puente de hormigón pretensado de aproximadamente 86 m de longitud. En esta aplicación, los efectos de temperatura, fueron un factor muy importante y se tuvo en cuenta su corrección para una interpretación correcta de los datos obtenidos. Por último, con base en lo observado a través de la información obtenida en cada uno de los ensayos experimentales comentados, se establecen las conclusiones en torno a las ventajas e inconvenientes de este tipo de sistemas opto-electrónicos de medición basados en el uso de SFOD, Cabe decir que la metodología propuesta en esta tesis produce unos resultados muy satisfactorios tanto en la detección, localización como cuantificación de la fisuración por flexión y cortante en estructuras de hormigón para niveles de solicitación de servicio.
- Published
- 2017
9. Monitorización de estructuras de hormigón mediante sensores de fibra óptica distribuida
- Author
-
Universitat Politècnica de Catalunya. Departament d'Enginyeria Civil i Ambiental, Casas Rius, Joan Ramon, Villalba Herrero, Sergi, Rodríguez Gutiérrez, Gerardo, Universitat Politècnica de Catalunya. Departament d'Enginyeria Civil i Ambiental, Casas Rius, Joan Ramon, Villalba Herrero, Sergi, and Rodríguez Gutiérrez, Gerardo
- Abstract
This doctoral thesis presents the use of an opto-electronic system so-called OBR (Optical Backscattered Reflectometer) as an alternative of measurement in structural health monitoring (SHM) processes in concrete structures, which may present cracks even for service loads. The main feature of the OBR system is its great sensitivity and high spatial resolution through the use of an optical fiber cable as a sensor, which is called the distributed optical fiber sensor (DOFS). Thanks to that, it becomes possible to obtain strain records where the presence of cracks can be identified and localized. Thus, the experience of an earlier application is first taken up and a method of calculating average crack width in concrete structures subjected to bending is proposed and it is based on information from the strain records obtained with the OBR system. Afterwards, the OBR system is applied to the study of three partially pre-stressed concrete (PPC) beams of 8 m in length and subjected to shear stress. These beams were instrumented both in conventional form with discrete sensors, and with a DOFS adhered to the surface. Based on the experimental results obtained, the capacity of the OBR system to monitor concrete structures subjected to shear is evaluated, and a method is proposed to detect, locate and subsequently quantify the average shear crack width. One of the three beams tested to shear and already with the presence of cracks along its entire length, is tested to flexion. In this test it is evaluated the system ability to detect the presence of existing cracks, and the appearance of new cracks. Once the main cracks have been detected and localized, the proposed method of calculating average crack width is again applied and the results checked. Finally, the application of the OBR system to a real structure is carried out. The above consisted in the monitoring over almost eight months of the process of enlarging a two-span pre-stressed concrete bridge with a total length of, En esta tesis doctoral se presenta el uso de un reflectómetro óptico de retrodispersión denominado sistema OBR (optical backscattered reflectometer por sus siglas en inglés), como una herramienta de monitorización de la salud estructural (MSE) en estructuras de hormigón, las cuales pueden presentar fisuras incluso en condiciones de servicio. La principal característica del sistema OBR es su gran sensibilidad y alta resolución espacial a través del uso de un cable de fibra óptica como sensor y que se denomina sensor de fibra óptica distribuida (SFOD). Lo anterior, produce registros de deformación en los cuales se puede identificar y localizar la presencia de fisuras. Así, en primer lugar se retoma la experiencia de una aplicación anterior, y se propone un método del cálculo de ancho de fisura promedio en estructuras de hormigón sujetas básicamente a flexión, y que se basa en la información de los registros de deformación que se obtienen con el sistema OBR. A continuación, el sistema OBR se aplica en el estudio de tres vigas de hormigón parcialmente pretensado (HPP) de 8 m de longitud y sujetas a esfuerzo cortante. Estas vigas fueron instrumentadas tanto en forma convencional con sensores discretos, como con un SFOD adherido a la superficie. Con base en los resultados experimentales obtenidos, se evalúa la capacidad del sistema OBR para monitorizar estructuras de hormigón sujetas a cortante, y se propone un método para detectar, localizar y posteriormente cuantificar el ancho de fisura promedio a cortante. Posteriormente, una de las tres vigas ensayadas a cortante y ya con la presencia de fisuras a lo largo de toda su longitud, es ensaya a flexión. En esta viga se evalúa la capacidad del sistema para detectar la presencia de fisuras ya existentes, y la aparición de nuevas fisuras. Una vez detectadas y localizadas las principales fisuras por flexión, se aplica el método del cálculo del ancho de fisura propuesto y se evalúan sus resultados. También se lleva a cabo la ap, Postprint (published version)
- Published
- 2017
Catalog
Discovery Service for Jio Institute Digital Library
For full access to our library's resources, please sign in.