106 results on '"Schmutz, B."'
Search Results
2. Is there a bone-nail specific entry point? Automated fit quantification of tibial nail designs during the insertion for six different nail entry points
- Author
-
Amarathunga, J.P., Schuetz, M.A., Yarlagadda, K.V.D., and Schmutz, B.
- Published
- 2015
- Full Text
- View/download PDF
3. DISTAL RADIUS FRACTURE CLASSIFICATION USING DEEP LEARNING ALGORITHMS
- Author
-
White, J., primary, Wadhawan, A., additional, Min, H., additional, Rabi, Y., additional, Schmutz, B., additional, Dowling, J., additional, Tchernegovski, A., additional, Bourgeat, P., additional, Tetsworth, K., additional, Fripp, J., additional, Mitchell, G., additional, Hacking, C., additional, Williamson, F., additional, and Schuetz, M., additional
- Published
- 2023
- Full Text
- View/download PDF
4. Assessing the bilateral geometrical differences of the tibia – Are they the same?
- Author
-
Radzi, S., Uesugi, M., Baird, A., Mishra, S., Schuetz, M., and Schmutz, B.
- Published
- 2014
- Full Text
- View/download PDF
5. Can the contra-lateral limb be used as a control with respect to analyses of bone remodelling?
- Author
-
Krishnakanth, P., Schmutz, B., Steck, R., Mishra, S., Schütz, M.A., and Epari, D.R.
- Published
- 2011
- Full Text
- View/download PDF
6. Quantitative fit assessment of tibial nail designs using 3D computer modelling
- Author
-
Schmutz, B., Rathnayaka, K., Wullschleger, M.E., Meek, J., and Schuetz, M.A.
- Published
- 2010
- Full Text
- View/download PDF
7. QUANTIFICATION OF FRACTURE CALLUS VOLUME FROM CT SCANS
- Author
-
Klaus, A. J., Schmutz, B., Wullschleger, M. E., Schuetz, M. A., and Steck, R.
- Published
- 2009
8. THE EFFECT OF DISTRACTION VECTOR ORIENTATION ON THE REGENERATE TISSUE DURING BILATERAL MANDIBULAR DISTRACTION
- Author
-
Mishra, S., Collier, L., Chen, G., Steck, R., Schmutz, B., Wullschleger, M., and Schütz, M.
- Published
- 2009
9. OPTIMISING A PERIARTICULAR FRACTURE FIXATION PLATE: DOES ONE SHAPE FIT ALL?
- Author
-
Schmutz, B., Wullschleger, M. E., Steck, R., and Schuetz, M. A.
- Published
- 2009
10. β-amyloid modulates tyrosine kinase B receptor expression in SHSY5Y neuroblastoma cells: influence of the antioxidant melatonin
- Author
-
Olivieri, G, Otten, U, Meier, F, Baysang, G, Dimitriades-Schmutz, B, Müller-Spahn, F, and Savaskan, E
- Published
- 2003
- Full Text
- View/download PDF
11. Magnetic resonance versus computed tomography: imaging bony fractures of the orbit with view to surgical reconstruction — a retrospective feasibility study
- Author
-
Cooper, T., primary, Schmutz, B., additional, Hsu, E., additional, and Lynham, A., additional
- Published
- 2017
- Full Text
- View/download PDF
12. Automated quantitative fit assessment of tibial nail designs during insertion using 3D computer modelling
- Author
-
Amarathunga Arachchige, J, Schütz, M, Yarlagadda, P, and Schmutz, B
- Subjects
ddc: 610 ,integumentary system ,610 Medical sciences ,Medicine - Abstract
Objective: Intramedullary nailing is the standard fixation method for displaced diaphyseal fractures of the tibia in adults. The optimal nail design should be easy to insert and anatomically fit the bone geometry at its final position. In a previous study, through a virtual manual fit quantification[for full text, please go to the a.m. URL], Deutscher Kongress für Orthopädie und Unfallchirurgie (DKOU 2013)
- Published
- 2013
- Full Text
- View/download PDF
13. Quantification of the Accuracy of MRI Generated 3D Models of Long Bones
- Author
-
Rathanayaka, K, Momot, K, Noser, H, Sahama, T, Schuetz, MA, and Schmutz, B
- Subjects
ddc: 610 ,610 Medical sciences ,Medicine - Abstract
Objective: Orthopaedic implants are typically designed using accurate computer tomography (CT) based 3D models of long bones. CT scans are used due to their high soft tissue-bone contrast. However, CT scanning exposes a subject to a high amount of ionising radiation making it unsuitable for acquisition[for full text, please go to the a.m. URL], Deutscher Kongress für Orthopädie und Unfallchirurgie; 74. Jahrestagung der Deutschen Gesellschaft für Unfallchirurgie, 96. Tagung der Deutschen Gesellschaft für Orthopädie und Orthopädische Chirurgie, 51. Tagung des Berufsverbandes der Fachärzte für Orthopädie
- Published
- 2010
- Full Text
- View/download PDF
14. A new approach for assigning bone material properties from CT images into finite element models
- Author
-
Chen, G., Schmutz, B., Epari, D., Rathnayaka, K., Ibrahim, S., Schuetz, M.A., and Pearcy, M.J.
- Published
- 2010
- Full Text
- View/download PDF
15. Beta-amyloid modulates tyrosine kinase B receptor expression in SHSY5Y neuroblastoma cells: influence of the antioxidant melatonin
- Author
-
Olivieri, G, Otten, U, Meier, F, Baysang, G, Dimitriades-Schmutz, B, Müller-Spahn, F, Savaskan, E, University of Zurich, and Olivieri, G
- Subjects
2800 General Neuroscience ,610 Medicine & health ,11359 Institute for Regenerative Medicine (IREM) - Published
- 2003
16. Quantitative fit assessment of tibial nail designs using 3D computer modelling
- Author
-
Schmutz, B, Rathnayaka, K, Wullschleger, ME, Meek, J, Schuetz, MA, Schmutz, B, Rathnayaka, K, Wullschleger, ME, Meek, J, and Schuetz, MA
- Published
- 2009
17. Computational investigations of mechanical failures of internal plate fixation.
- Author
-
Chen G, Schmutz B, Wullschleger M, Pearcy MJ, Schuetz MA, Chen, G, Schmutz, B, Wullschleger, M, Pearcy, M J, and Schuetz, M A
- Abstract
This paper investigated the biomechanics of two clinical cases of bone fracture treatments. Both fractures were treated with the same locking compression plate but with different numbers of screws as well as different plate materials. The fracture treated with 12 screws (rigid fixation) failed at 7 weeks with the plate breaking; the fracture with six screws (flexible fixation) endured the entire healing process. It was hypothesized that the plate failure in the unsuccessful case was due to the material fatigue induced by stress concentration in the plate. As the two clinical cases had different fracture locations and different plate materials, finite element simulations were undertaken for each fractured bone fixed by both a rigid and a flexible method. This enabled comparisons to be made between the rigid and flexible fixation methods. The fatigue life was assessed for each fixation method. The results showed that the stress in the rigid fixation methods could be significantly higher than that in flexible fixation methods. The fatigue analyses showed that, with the stress level in flexible fixation (i.e. with fewer screws), the plate was able to endure 2000 days, and that the plate in rigid fixation could fail by fatigue fracture in 20 days. The paper concludes that the rigid fixation method resulted in serious stress concentrations in the plate, which induced fatigue failure. The flexible fixation gave sufficient stability and was better for fracture healing. [ABSTRACT FROM AUTHOR]
- Published
- 2010
18. Computational investigations of mechanical failures of internal plate fixation
- Author
-
Chen, G, primary, Schmutz, B, additional, Wullschleger, M, additional, Pearcy, M J, additional, and Schuetz, M A, additional
- Published
- 2009
- Full Text
- View/download PDF
19. Customization of a generic 3D model of the distal femur using diagnostic radiographs
- Author
-
Schmutz, B., primary, Reynolds, K. J., additional, and Slavotinek, J. P., additional
- Published
- 2008
- Full Text
- View/download PDF
20. DEVELOPMENT OF SLOW RELEASE SURFACE COATINGS FOR THE PREVENTION AND TREATMENT OF BACTERIAL INFECTIONS ASSOCIATED WITH FRACTURE-FIXATION DEVICES(3A3 Cellular & Tissue Engineering & Biomaterials III)
- Author
-
Stemberger, Michaela, primary, Steck, Roland, additional, McMillan, David J., additional, Goss, Ben, additional, Stemberger, Axel, additional, Schmutz, B., additional, and Schuetz, Michael A., additional
- Published
- 2007
- Full Text
- View/download PDF
21. Oxidative Stress Modulates Tyrosine Kinase Receptor A and p75 Receptor (Low-Affinity Nerve Growth Factor Receptor) Expression in SHSY5Y Neuroblastoma Cells
- Author
-
Olivieri, G., primary, Otten, U., additional, Meier, F., additional, Baysang, G., additional, Dimitriades-Schmutz, B., additional, Müller-Spahn, F., additional, and Savaskan, E., additional
- Published
- 2002
- Full Text
- View/download PDF
22. Expression of functional trk tyrosine kinase receptors after T cell activation.
- Author
-
Ehrhard, P B, primary, Erb, P, additional, Graumann, U, additional, Schmutz, B, additional, and Otten, U, additional
- Published
- 1994
- Full Text
- View/download PDF
23. Fit assessment of anatomic plates for the distal medial tibia.
- Author
-
Schmutz B, Wullschleger ME, Kim H, Noser H, and Schütz MA
- Published
- 2008
- Full Text
- View/download PDF
24. Grundriss der Industriestatistik, I G. Forbrig
- Author
-
Schmutz, B.
- Published
- 1968
- Full Text
- View/download PDF
25. Oxidative stress modulates trk A and p75 (LNGRF) receptor expression in SHSY5Y neuroblastoma cells
- Author
-
Olivieri, G., Otten, U., Meier, F., Baysang, G., Dimitriades-Schmutz, B., Müller-Spahn, F., and Savaskan, E.
- Published
- 2002
- Full Text
- View/download PDF
26. Expression of low-affinity NGF receptor and trkB mRNA in human SH-SY5Y neuroblastoma cells
- Author
-
Ehrhard, P. B., Ganter, U., Schmutz, B., and Bauer, J.
- Published
- 1993
- Full Text
- View/download PDF
27. Modular design workflow for 3D printable bioresorbable patient-specific bone scaffolds: extended features and clinical validation.
- Author
-
Herath B, Laubach M, Suresh S, Schmutz B, Little JP, Yarlagadda PKDV, Delbrück H, Hildebrand F, Hutmacher DW, and Wille ML
- Abstract
A previously in-house developed patient-specific scaffold design workflow was extended with new features to overcome several limitations and to broaden its adaptability to diverse bone defects, thereby enhancing its fit for routine clinical use. It was applied to three clinical cases for further validation. A virtual surgical resection tool was developed to remove regions of the bone defect models. The minor cavity fill module enabled the generation of scaffold designs with smooth external surfaces and the segmental defect fill module allowed a versatile method to fill a segmental defect cavity. The boundary representation method based surgical approach module in the original workflow was redeveloped to use functional representation, eliminating previously seen resolution dependant artefacts. Lastly, a method to overlay the scaffold designs on computed tomography images of the defect for design verification by the surgeon was introduced. The extended workflow was applied to two ongoing clinical case studies of a complex bilateral femoral defect and a humerus defect, and also to a case of a large volume craniomaxillofacial defect. It was able to successfully generate scaffolds without any obstructions to their surgical insertion which was verified by digital examination as well as using physical 3D printed models. All produced surface meshes were free from 3D printing mesh errors. The scaffolds designed for the ongoing cases were 3D printed and successfully surgically implanted, providing confidence in the extended modular workflow's ability to be applied to a broad range of diverse clinical cases., Competing Interests: DH is a cofounder of Osteopore International Pty Ltd., a company specialised in 3D printed bioresorbable implants to assist with bone healing. The remaining authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as potential conflicts of interest., (Copyright © 2024 Herath, Laubach, Suresh, Schmutz, Little, Yarlagadda, Delbrück, Hildebrand, Hutmacher and Wille.)
- Published
- 2024
- Full Text
- View/download PDF
28. An evolutionary perspective to intramedullary nail fit - comparing present-day data with a historical specimen collection.
- Author
-
Schmutz B, Rühli F, Schuetz F, and Eppenberger P
- Subjects
- Humans, Bone Nails, Femur anatomy & histology, Fracture Fixation, Intramedullary methods, Femoral Fractures surgery
- Abstract
Manufacturers aim to design implants fitting for the broadest possible population segment. Due to the scarcity of available morphological data of intact long bones, anatomical collections of historical bone specimens may represent valuable additional sources. Previous work on femoral morphology measurements suggests that historical specimens are widely consistent with data from present-day populations. This study aimed to investigate whether this also applies to the anatomical fitting of a clinically used femoral nail. Nail fit was computer-graphically quantified through virtual implantation into CT-based 3D models of 52 femora, comprising a subset representative of the present-day Caucasian population (n = 31), a subset from a historical medieval European bone collection (n = 20), and additionally, a dataset from a natural ice mummy from the Neolithic period. Nail fit was assessed by nail protrusion (area and distance) to the inner cortex surface and the distal nail tip's position in the medullary canal. Assessed measurements and parameters of the present-day Caucasian subset were mostly consistent with those of the medieval European subset. After adjusting for multiple testing, only the distance from lateral nail entry point to shaft axis remained significantly ( p = 0.03) different when comparing our modern and medieval subsets. Subsequent bivariate (Spearman) correlation analyses for both subsets (modern and medieval) combined showed that of the three variables representing basic demographic parameters, individual age, biological sex, and femur length, most statistically significant associations to the examined nail fit measurements were found for age (six measurements at a level of p < 0.05), however, with a relatively weak monotonic correlation (rho values ranging between ±0.31 and ±0.37). The measurements for the Iceman's femur lie within the range of the modern and historical subgroups, but in some cases, differ by more than one standard deviation from the mean. Our results confirm previous findings, suggesting that more recent historical bone specimen collections may indeed be a convenient and easily accessible source of new 3D morphological data and complement existing data to be used for the development of femoral nails.
- Published
- 2024
- Full Text
- View/download PDF
29. Are Magnetic Resonance Imaging-Generated 3Dimensional Models Comparable to Computed Tomography-Generated 3Dimensional Models for Orbital Fracture Reconstruction? An In-Vitro Volumetric Analysis.
- Author
-
Milham N, Schmutz B, Cooper T, Hsu E, Hutmacher DW, and Lynham A
- Subjects
- Adult, Humans, Male, Female, Young Adult, Retrospective Studies, Tomography, X-Ray Computed methods, Orbit diagnostic imaging, Orbit surgery, Magnetic Resonance Imaging, Orbital Fractures diagnostic imaging, Orbital Fractures surgery
- Abstract
Background: Magnetic resonance imaging (MRI) is being increasingly considered as an alternative for the evaluation and reconstruction of orbital fractures. No previous research has compared the orbital volume of an MRI-imaged, three-dimensional (3D), reconstructed, and virtually restored bony orbit to the gold standard of computed tomography (CT)., Purpose: To measure the orbital volumes generated from MRI-based 3D models of fractured bony orbits with virtually positioned prebent fan plates in situ and compare them to the volumes of CT-based virtually reconstructed orbital models., Study Design: This retrospective in-vitro study used CT and MRI data from adult patients with orbital trauma assessed at the Royal Brisbane and Women's Hospital Outpatient Maxillofacial Clinic from 2011 to 2012. Only those with orbital blowout fractures were included in the study., Predictor Variable: The primary predictor variable was imaging modality, with CT- and MRI-based 3D models used for plate bending and placement., Main Outcome Variable: The primary outcome variable was the orbital volume of the enclosed 3D models., Covariates: Additional data collected was age, sex, and side of fractured orbit. The effect of operator variability on plate contouring and orbital volume was quantified., Analyses: The Wilcoxon signed rank test was used to assess differences between orbital volumes with a significance level P < .05., Results: Of 11 eligible participants, six patients (four male and two female; mean age 31 ± 8.6 years) were enrolled. Two sets of six CT-based virtually restored orbits were smaller than the intact contralateral CT models by an average of 1.02 cm
3 (95% CI -0.07 to 2.11 cm3 ; P = .028) and 0.99 cm3 (95% CI 0.07 to 1.91 cm3 ; P = .028), respectively. The average volume difference between the MRI-based virtually restored orbit and the intact contralateral MRI model was 0.97 cm3 (95% CI -1.08 to 1.94 cm3 ; P = .75). Imaging modality did affect orbital volume difference for 1 set of CT and MRI models (0.63 cm3 ; 95% CI -0.11 to 1.29 cm3 ; P = .046) but not the other (0.69 cm3 ; 95% CI -0.11 to 1.23 cm3 ; P = .075). Single operator variability in plate bending did not result in significant (P = .75) volume differences., Conclusions: MRI can be used to reconstruct orbital volume with a clinically acceptable level of accuracy., (Crown Copyright © 2023. Published by Elsevier Inc. All rights reserved.)- Published
- 2023
- Full Text
- View/download PDF
30. Automatic classification of distal radius fracture using a two-stage ensemble deep learning framework.
- Author
-
Min H, Rabi Y, Wadhawan A, Bourgeat P, Dowling J, White J, Tchernegovski A, Formanek B, Schuetz M, Mitchell G, Williamson F, Hacking C, Tetsworth K, and Schmutz B
- Subjects
- Humans, Radiography, Wrist Fractures, Radius Fractures diagnostic imaging, Deep Learning, Intra-Articular Fractures diagnostic imaging
- Abstract
Distal radius fractures (DRFs) are one of the most common types of wrist fracture and can be subdivided into intra- and extra-articular fractures. Compared with extra-articular DRFs which spare the joint surface, intra-articular DRFs extend to the articular surface and can be more difficult to treat. Identification of articular involvement can provide valuable information about the characteristics of fracture patterns. In this study, a two-stage ensemble deep learning framework was proposed to differentiate intra- and extra-articular DRFs automatically on posteroanterior (PA) view wrist X-rays. The framework firstly detects the distal radius region of interest (ROI) using an ensemble model of YOLOv5 networks, which imitates the clinicians' search pattern of zooming in on relevant regions to assess abnormalities. Secondly, an ensemble model of EfficientNet-B3 networks classifies the fractures in the detected ROIs into intra- and extra-articular. The framework achieved an area under the receiver operating characteristic curve of 0.82, an accuracy of 0.81, a true positive rate of 0.83 and a false positive rate of 0.27 (specificity of 0.73) for differentiating intra- from extra-articular DRFs. This study has demonstrated the potential in automatic DRF characterization using deep learning on clinically acquired wrist radiographs and can serve as a baseline for further research in incorporating multi-view information for fracture classification., (© 2023. Crown.)
- Published
- 2023
- Full Text
- View/download PDF
31. Local Antibiotic Delivery Options in Prosthetic Joint Infection.
- Author
-
Steadman W, Chapman PR, Schuetz M, Schmutz B, Trampuz A, and Tetsworth K
- Abstract
Prosthetic Joint Infection (PJI) causes significant morbidity and mortality for patients globally. Delivery of antibiotics to the site of infection has potential to improve the treatment outcomes and enhance biofilm eradication. These antibiotics can be delivered using an intra-articular catheter or combined with a carrier substance to enhance pharmacokinetic properties. Carrier options include non-resorbable polymethylmethacrylate (PMMA) bone cement and resorbable calcium sulphate, hydroxyapatite, bioactive glass, and hydrogels. PMMA allows for creation of structural spacers used in multi-stage revision procedures, however it requires subsequent removal and antibiotic compatibility and the levels delivered are variable. Calcium sulphate is the most researched resorbable carrier in PJI, but is associated with wound leakage and hypercalcaemia, and clinical evidence for its effectiveness remains at the early stage. Hydrogels provide a versatile combability with antibiotics and adjustable elution profiles, but clinical usage is currently limited. Novel anti-biofilm therapies include bacteriophages which have been used successfully in small case series.
- Published
- 2023
- Full Text
- View/download PDF
32. Extraction force, energy and nail deformation for 1.5 m versus 1.0 m intramedullary femoral nail bow design: A biomechanical investigation.
- Author
-
Yuan H, Schmutz B, Varga P, Gueorguiev B, Zderic I, Windolf M, and Acklin Y
- Subjects
- Humans, Bone Nails, Femur surgery, Lower Extremity, Biomechanical Phenomena, Femoral Fractures surgery, Fracture Fixation, Intramedullary methods
- Abstract
Background: The impact of the nail radius of curvature, as one of the most important design features in modern femoral nails on the ease of nail removal, remains unknown. Therefore, the aim of this study was to investigate force, energy, and nail deformation of different nail designs., Methods: Nail insertion and extraction was performed on six pairs of fresh-frozen human cadaveric femora on a material testing machine with two different nail systems - Trochanter femoral nail ADVANCED™ Nailing System with a radius of curvature of 1.0 m and Proximal Femoral Nail Antirotation System with a radius of curvature of 1.5 m. Deformation was measured after insertion (plastic and elastic deformations) and extraction (plastic deformations)., Findings: The peak force during nail removal was significantly lower in the first group (274.5 ± 130.4 N) compared to the second group (695.2 ± 158.8 N, p = 0.001). Plastic deformation was observed in all implants, being significantly larger in the Proximal Femoral Nail Antirotation System (p = 0.027). There was a strong positive correlation between the first peak force during nail removal and nail insertion (r = 0.802, p = 0.002) as well as between extracting energy and insertion energy (r = 0.943, p < 0.001)., Interpretation: The results from this study showed that a radius of curvature of 1.0 m is easier to remove from the set of cadaver femora. Furthermore, our findings support the idea of further reducing the nail radius of curvature below 1.0 m in order to more closely match the anatomy of populations with strong-bowed femora., Competing Interests: Declaration of Competing Interest The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper., (Copyright © 2023. Published by Elsevier Ltd.)
- Published
- 2023
- Full Text
- View/download PDF
33. Potential pitfalls of lateral radiographic assessment of the nail position in the distal femur.
- Author
-
Sarai H, Schmutz B, and Schuetz M
- Subjects
- Bone Nails, Femur diagnostic imaging, Femur surgery, Humans, Radiography, Femoral Fractures diagnostic imaging, Femoral Fractures surgery, Fracture Fixation, Intramedullary methods
- Abstract
Introduction: Antegrade nailing of proximal femur fractures is a widely accepted treatment that relies on lateral radiographs to assess distal nail positioning. However, the distal femur is trapezoidal in cross section, consequently standard lateral radiographs may be insufficient. This study aimed to utilise 3D modelling to virtually assess the accuracy of lateral radiographs in defining the position of a femoral nail in the distal femur, specifically considering distal cortical encroachment., Materials and Methods: Three-dimensional models of a commonly used nail, were positioned in 3D models of 63 femora, generated from CT scans. Lateral projections, representative of lateral radiographs, were generated and measurements of the closest point distance between the distal nail and anterior inner cortex were recorded. Axial slices through the model at the same distal position were produced for any nails located in the canal's anterior 1/5th and used to quantify the shortest nail to anterior cortex distance., Results: A significant (p = 0.000) difference exists between the positions of the nail in the lateral projection (- 1.7 ± 1.24 mm) compared with axial position (- 0.23 ± 1.41 mm) with reference to the inner cortical surface. In the lateral projection, 30 nails were located in the canal's anterior 1/5th, of these, 14 nails were identified in the axial position as perforating the inner cortex, with four also perforating the outer cortex surface., Conclusion: Femoral nails are often anteriorly located in the distal femur and reviewed using lateral radiographs. However, this research demonstrates that owing to the geometry of the distal femur, a lateral radiograph may be inadequate for determining the true position of a femoral nail within the distal femur. Accurately assessing the position of femoral nails may help to address and prevent thigh pain, and iatrogenic fracture or perforation which have been associated with anterior positioning., (© 2021. The Author(s), under exclusive licence to Springer-Verlag GmbH Germany, part of Springer Nature.)
- Published
- 2022
- Full Text
- View/download PDF
34. A Simple Method to Improve Detection of Femoral Nail Abutment in the Distal Femur: A Computer Modeling Study.
- Author
-
Sarai H, Schmutz B, and Schuetz M
- Subjects
- Aged, Aged, 80 and over, Computers, Female, Femur diagnostic imaging, Femur surgery, Humans, Male, Radiography, Femoral Fractures diagnostic imaging, Femoral Fractures surgery, Fracture Fixation, Intramedullary methods
- Abstract
Background: Proximal femur fractures are more frequently treated with long femoral nails. Lateral radiographs are used to assess the nail position in the distal femur. However, because of the asymmetric shape of the distal femur, standard lateral radiographs alone are suboptimal for assessing anteriorly positioned nails in the distal femur. Consequently, instances of nail abutment or even perforation might be missed intraoperatively., Question/purpose: Using a three-dimensional (3D) modelling approach, we asked: When the nail is in the anterior fifth of the canal, will rotating the femur to align the simulated x-ray beam with the anterior femoral condyles instead of the posterior femoral condyles increase the diagnostic accuracy of detecting nail perforation of the anterior cortex?, Methods: 3D models of 42 unilateral femora from a population sample representative of patients with hip fractures (mean age of 76 ± 7 years, 10 males and 32 females, and 16 left and 26 right femora) were used. The patients had a mean height of 158 ± 9 cm; 27 femora were from Asians and 15 were from Caucasians. Clinically appropriately sized nails had already been virtually implanted previously as part of a quantitative nail fit assessment study. In a preliminary step, the mean angles of inclination of the distal anterior supracondylar region were quantified using four axial sections of the distal femur. For the femora with the nail tip in the anterior fifth of the canal, projections representing a lateral radiograph were generated along with rotated projections at mean angle (5°, 8°) rotations, with the anterior femoral condyles aligned, and anterior femoral condyle alignment followed by internal and external rotation to detect maximum nail perforation. The distance from the nail to the distal anterior cortex was measured for each rotational projection and used to detect anterior nail perforation. The accuracy of detection was assessed using the area under the curve (AUC) of the receiver operating characteristic (ROC) analysis., Results: Rotating the 3D models by aligning the x-ray beam with the anterior femoral condyles improves the diagnostic ability of detecting anterior nail perforation compared with standard lateral radiographs. The AUC increased with rotation from 0.50 (95% confidence interval 0.50 to 0.50) on the lateral projection to 0.73 (95% CI 0.57 to 0.88, difference = -0.23; p = 0.004) at 5° of rotation, 0.77 (95% CI 0.62 to 0.93, difference = -0.27; p = 0.001) at both 8° of rotation and with the anterior femoral condyles aligned, and to 0.82 (95% CI 0.67 to 0.97, difference = -0.32; p < 0.001) with internal/external rotations past the anterior femoral condyles. There were no differences in accuracy between the four methods of rotation., Conclusion: This study shows that rotating the femur to align the anterior femoral condyles on a lateral radiograph and then internally/externally rotating it, improves the accuracy assessed via the AUC of detecting anterior perforation when long nails are positioned in the anterior fifth of the distal femur., Clinical Relevance: This approach can easily be used in a clinical setting. Intraoperatively, the image intensifier can be rotated around the leg to produce an image with the anterior femoral condyle aligned, providing surgeons with an opportunity to identify and improve the nail's position or exchange the nail while the patient is still under anesthesia., Competing Interests: Each author certifies that there are no funding or commercial associations (consultancies, stock ownership, equity interest, patent/licensing arrangements, etc.) that might pose a conflict of interest in connection with the submitted article related to the author or any immediate family members. All ICMJE Conflict of Interest Forms for authors and Clinical Orthopaedics and Related Research® editors and board members are on file with the publication and can be viewed on request., (Copyright © 2022 by the Association of Bone and Joint Surgeons.)
- Published
- 2022
- Full Text
- View/download PDF
35. A humanised rat model of osteosarcoma reveals ultrastructural differences between bone and mineralised tumour tissue.
- Author
-
Lahr CA, Landgraf M, Wagner F, Cipitria A, Moreno-Jiménez I, Bas O, Schmutz B, Meinert C, Cavalcanti ADS, Mashimo T, Miyasaka Y, Holzapfel BM, Shafiee A, McGovern JA, and Hutmacher DW
- Subjects
- Animals, Bone and Bones pathology, Cell Line, Cell Line, Tumor, Humans, Rats, Tissue Engineering, Bone Neoplasms secondary, Osteosarcoma drug therapy
- Abstract
Current xenograft animal models fail to accurately replicate the complexity of human bone disease. To gain translatable and clinically valuable data from animal models, new in vivo models need to be developed that mimic pivotal aspects of human bone physiology as well as its diseased state. Above all, an advanced bone disease model should promote the development of new treatment strategies and facilitate the conduction of common clinical interventional procedures. Here we describe the development and characterisation of an orthotopic humanised tissue-engineered osteosarcoma (OS) model in a recently genetically engineered x-linked severe combined immunodeficient (X-SCID) rat. For the first time in a genetically modified rat, our results show the successful implementation of an orthotopic humanised tissue-engineered bone niche supporting the growth of a human OS cell line including its metastatic spread to the lung. Moreover, we studied the inter- and intraspecies differences in ultrastructural composition of bone and calcified tissue produced by the tumour, pointing to the crucial role of humanised animal models., (Crown Copyright © 2021. Published by Elsevier Inc. All rights reserved.)
- Published
- 2022
- Full Text
- View/download PDF
36. A deep learning method for automatic segmentation of the bony orbit in MRI and CT images.
- Author
-
Hamwood J, Schmutz B, Collins MJ, Allenby MC, and Alonso-Caneiro D
- Subjects
- Humans, Neural Networks, Computer, Deep Learning, Magnetic Resonance Imaging methods, Orbit diagnostic imaging, Tomography, X-Ray Computed methods
- Abstract
This paper proposes a fully automatic method to segment the inner boundary of the bony orbit in two different image modalities: magnetic resonance imaging (MRI) and computed tomography (CT). The method, based on a deep learning architecture, uses two fully convolutional neural networks in series followed by a graph-search method to generate a boundary for the orbit. When compared to human performance for segmentation of both CT and MRI data, the proposed method achieves high Dice coefficients on both orbit and background, with scores of 0.813 and 0.975 in CT images and 0.930 and 0.995 in MRI images, showing a high degree of agreement with a manual segmentation by a human expert. Given the volumetric characteristics of these imaging modalities and the complexity and time-consuming nature of the segmentation of the orbital region in the human skull, it is often impractical to manually segment these images. Thus, the proposed method provides a valid clinical and research tool that performs similarly to the human observer.
- Published
- 2021
- Full Text
- View/download PDF
37. Morphological analysis of Gissane's angle utilising a statistical shape model of the calcaneus.
- Author
-
Schmutz B, Lüthi M, Schmutz-Leong YK, Shulman R, and Platt S
- Subjects
- Fractures, Bone diagnostic imaging, Fractures, Bone pathology, Humans, Tomography, X-Ray Computed, Ankle anatomy & histology, Ankle diagnostic imaging, Calcaneus anatomy & histology, Calcaneus diagnostic imaging, Calcaneus injuries, Models, Statistical
- Abstract
Introduction: Gissane's crucial angle (GA) facilitates to diagnose calcaneal fractures, and serves as an indicator of the quality of anatomical reduction after fixation. The study aimed to utilise statistical shape models (SSM) for analysing the complex 3D surface anatomy of the calcaneus represented by the simplified GA measurement on lateral radiographs., Materials and Methods: SSMs were generated from CT scans of paired adult calcanei from 10 Japanese and 31 Thai specimens. GA measurements in 3D and 2D were obtained for the lateral, central and medial anatomy of the posterior facet and sinus tarsi. The correlation between calcaneal length and GA was analysed. Regression and principal component (PC) analyses were conducted for analysing morphological variability in calcaneal shape relating to GA. The bilateral symmetry of the obtained measurements was analysed., Results: The mean GA (lateral) for the Japanese specimens was 105.1° ± 7.5 and 105.4° ± 8.5 for the Thai. The projected 2D angles of the central and medial measurements were larger (P < 0.00) than the 3D values. The medial projected 2D angles were larger (P ≤ 0.02) compared to the lateral. Despite the bilateral symmetry of GA and calcaneal length, their correlation displayed clear signs of asymmetry, which was confirmed by regression and PC analyses., Conclusions: Japanese and Thai specimens revealed lower GAs (both range and mean) compared to reported reference values of other ethnicities. As a reduced GA is generally indicative of a calcaneal fracture, our results are important to surgeons for their diagnostic assessment of Japanese and Thai patients. The results indicate that the GA measurement on a plain radiograph is a simplified representation of the lateral-to-central 3D calcaneal anatomy but significantly underestimates the angle measurement on the medial aspects of the respective surface areas.
- Published
- 2021
- Full Text
- View/download PDF
38. Effects of ethnicity on proximal femoral intramedullary nail protrusion-a 3D computer graphical analysis.
- Author
-
Sarai H, Schmutz B, and Schuetz M
- Subjects
- Asian People statistics & numerical data, Femoral Fractures diagnostic imaging, Femur diagnostic imaging, Humans, Imaging, Three-Dimensional, White People statistics & numerical data, Bone Nails adverse effects, Femoral Fractures surgery, Femur surgery, Fracture Fixation, Intramedullary adverse effects, Fracture Fixation, Intramedullary instrumentation, Postoperative Complications ethnology
- Abstract
Introduction: Antegrade nailing of proximal femur or femoral shaft fractures is a proven treatment with good to excellent results. Nonetheless, clinical evidence from Asia indicates that proximal femur nails can be too proud at the greater trochanter (GT) causing irritation for some Asian patients. This study aimed to identify any significant differences in proximal nail misfit for a set of Asian and Caucasian femora., Materials and Methods: Two nails (Gamma3, TFNA) were virtually inserted into 63 femoral 3D models (28 Japanese, 4 Thai, 31 Caucasian). In AP, the entry point was 4° lateral for Gamma3 and 5° for TFNA; laterally the same location was used for both. Insertion depth was controlled by aligning the lag screw centre head. The distance of the nail end from the GT was measured at five (medial, lateral, anterior, posterior and centre) reference points (RPs). The correlation between GT height, CCD angle and proximal nail distance to GT was analysed., Results: There was no significant difference between either nail (p = 1.0). The TFNA was overall less prominent than the Gamma3, and significantly less prominent at all RPs except lateral. The Asian femora were 3.76 (p = 0.016) times more likely to have the nail protruding proximally. The Asian subjects were shorter (p < 0.05) than the Caucasians. Their GT height was slightly shorter and CCD angles larger compared to Caucasian (Asian: 41.1 mm, 128.1°, Caucasian: 42.2 mm, 126.4°), but the differences were not significant (p = 0.36). Stature, GT height and CCD angle significantly correlated with nail distance to GT., Conclusions: This study illustrated a significantly increased incidence of proximal nail protrusion in Asian compared to Caucasian femora, corroborating clinical findings. The combination of shorter stature and GT height and a larger CCD angle in Asians likely contributes to this difference.
- Published
- 2021
- Full Text
- View/download PDF
39. Secular evolution of femoral morphology from a clinical perspective.
- Author
-
Schmutz B, Schuetz F, Alkadhi H, Rühli F, and Eppenberger P
- Subjects
- Adult, Age Factors, Aged, Aged, 80 and over, Bone Nails, Equipment Design, Female, Fracture Fixation, Intramedullary instrumentation, Humans, Imaging, Three-Dimensional, Male, Middle Aged, Tomography, X-Ray Computed, White People, Femur anatomy & histology, Femur diagnostic imaging
- Abstract
Introduction: Intramedullary nailing is the surgical method of choice for the treatment of proximal femur or femoral shaft fractures. Implant manufacturers aim to design implants fitting for the broadest possible population segment. As complete morphological data sets of long bones are not widely available, anatomical collections of historical dry bone specimens may represent abundant additional sources of morphological three-dimensional (3D) data for implant design, provided they are consistent with present populations. This study aims to investigate secular trends and age-related changes of femoral morphology of the Caucasian population over the past 800 years., Materials and Methods: Computer graphical measurements of 3D-datasets of right and left femora derived from computed tomography (CT) scans, representative of the present Caucasian population, were compared to computer graphical measurements of 3D-datasets of right and left femora derived from CT scans of specimens from a historical medieval European bone collection., Results: Clinically relevant parameters of historical medieval European femora were found mostly consistent with correlative data of the present Caucasian population. Additionally, for some of the evaluated parameters, particularly anteversion, morphological differences significantly correlated to individual age and sex could be identified, whereas other parameters such as caput-collum-diaphyseal angle or radius of anterior femoral bowing were not correlated to individual age or sex., Conclusion: The findings suggest that more recent historical specimen collections may be a convenient and easily accessible source of new 3D morphological data, as well as to complement existing data, to be used by researchers and manufacturers for the development of intramedullary femoral nails., (© 2020 Wiley Periodicals, Inc.)
- Published
- 2020
- Full Text
- View/download PDF
40. Anatomical fitting of a plate shape directly derived from a 3D statistical bone model of the tibia.
- Author
-
Schmutz B, Rathnayaka K, and Albrecht T
- Abstract
Introduction: Intra- and inter-population variations of bone morphology have made the process of designing an anatomically well-fitting fracture fixation plate challenging. Although statistical bone models have recently been used for analysing morphological variabilities, it is not known to what extent they would also provide the basis for the design of a new plate shape. This would be particularly valuable in the case where no existing plate shape is available to start the process of fit optimisation. Therefore, this study investigated the anatomical fitting of a plate shape (statistical plate) derived from the mean shape of a statistical 3D tibia bone model in comparison to results available from two other plate shapes., Methods: Forty-five 3D bone models of tibiae from Japanese cadaver specimens, as well as 3D models of the plate undersurface of both a commercial and shape optimised Medial Distal Tibia Plate, were utilised from earlier studies. The mean shape of the 3D statistical bone model was generated from the tibia models utilising the Statismo framework. With reverse engineering software, the plate undersurface of the statistical plate shape was derived directly from the mean surface of the statistical 3D bone model. Through an iterative process, the statistical plate model was placed at the correct surgical position on each bone model for fit assessment., Results: The statistical plate was fitting for 20% of the tibiae compared to 13% for the commercial and 67% for the optimised plate, respectively., Conclusions: The plate shape derived directly from a statistical bone model was fitting better than the commercial plate, but considerably inferior to that of an optimised plate. However, the results do clearly indicate that this approach provides an appropriate and solid basis for commencing shape optimisation of the statistical plate. Studies of other anatomical regions are required to confirm whether these findings can be generalised., (© 2019 Delhi Orthopedic Association. All rights reserved.)
- Published
- 2019
- Full Text
- View/download PDF
41. Approach for analytical characterization and toxicological assessment of ozonation products in drinking water on the example of acesulfame.
- Author
-
Buchner EM, Happel O, Schmidt CK, Scheurer M, Schmutz B, Kramer M, Knauer M, Gartiser S, and Hollert H
- Subjects
- Sweetening Agents, Drinking Water, Ozone, Thiazines, Water Pollutants, Chemical, Water Purification
- Abstract
The monitoring and control of drinking water quality is generally important as it significantly contributes to the health of the population. In this context, particular attention has to be paid to the use of treatment techniques during drinking water treatment. It is known that the formation of reaction products (transformation products) has to be taken into account when oxidizing agents such as ozone are used. Different transformation products are classified as critical to health and require analytical examination. The risk assessment for previously unknown transformation products can be difficult as far as not all transformation products are present as single substances or the individual substances are not present in a sufficient high concentration or cannot be isolated from the original solution. The aim of this work is to show exemplarily the identification and quantification of ozonation products (OPs) after ozonation and their toxicological characterization, using the artificial sweetener acesulfame. It was shown that OPs can be fully characterized using ion chromatography in combination with different detection systems. A major OP could be recovered as a pure substance by crystallization and direct genotoxicological testing was possible without previous enrichment processes. Acesulfame samples of different concentrations in ultrapure and in drinking water after ozonation were tested in several genotoxicity tests. These tests revealed genotoxic effects of acesulfame after ozonation in ultrapure water in several genotoxicological test systems (micronucleus test, umu test, Ames-fluctuation-test and comet assay). In contrast, the crystallized ozonation product OP168 did not show any positive effects. Therefore, it seems likely that the observed effect was caused by the second major product OP170. However, a sufficiently large amount of analytically pure substance OP170 could not be obtained. It was also shown that the rate of the OP170 formation in drinking water is significantly lower than in ultrapure water and that ozonation in drinking water did not induce genotoxic effects., (Copyright © 2019 Elsevier Ltd. All rights reserved.)
- Published
- 2019
- Full Text
- View/download PDF
42. Bayesian modeling predicts age and sex are not required for accurate stature estimation from femoral length.
- Author
-
Reynolds MS, MacGregor DM, Alston-Knox CL, Meredith M, Barry MD, Schmutz B, and Gregory LS
- Subjects
- Adolescent, Adult, Aged, Australia, Forensic Anthropology, Humans, Imaging, Three-Dimensional, Linear Models, Middle Aged, Posture, Tomography, X-Ray Computed, Young Adult, Bayes Theorem, Body Height, Femur anatomy & histology, Femur diagnostic imaging
- Abstract
Despite the recognized flaws in applying traditional stature estimation equations such as those of Trotter and Gleser (1952) [5] to a contemporary population, there are currently no available alternatives for stature estimation in Australia that address these limitations. Post mortem computed tomography (PMCT) DICOM scans of the left and right femora were acquired from 76 Australian deceased individuals aged 17-76 years for metric analysis. Femoral bicondylar length, femoral epicondylar breadth and anterior-posterior (AP) diameter, medial-lateral (ML) diameter, circumference and cortical area at the femoral midshaft were measured on three-dimensional (3D) models to build statistical models for estimating stature. In addition, Australian individuals aged 16-63 years (n=111) were measured in standing and supine positions to aid in the adjustment of supine stature of deceased individuals utilized in this study to standing stature. The results of this preliminary evaluation strongly indicate that the optimal model for estimating stature includes bicondylar femoral length and epicondylar breadth, that the effect of sex as an independent variable is very low, and there is limited practical benefit in including age in the estimation of stature. Our study indicates that the Australian population sampled represents a small yet significant shift in stature from the original Trotter and Gleser sample. Additionally, in the case of fragmentary remains, it was found that epicondylar breadth and AP diameter had the highest probability of accurate stature estimation in the absence of bicondylar femoral length. As stature forms a significant component of a biological profile and therefore aids in the personal identification of human remains, it is important that forensic anthropologists utilize the most accurate methodologies available. Stature estimation of Australian individuals is therefore achieved with higher accuracy through utilizing the femoral equations proposed in this study., (Copyright © 2018 Elsevier B.V. All rights reserved.)
- Published
- 2018
- Full Text
- View/download PDF
43. Standardized anthropological measurement of postcranial bones using three-dimensional models in CAD software.
- Author
-
Reynolds MS, MacGregor DM, Barry MD, Lottering N, Schmutz B, Wilson LJ, Meredith M, and Gregory LS
- Subjects
- Forensic Anthropology methods, Humans, Reproducibility of Results, Software, Bone and Bones anatomy & histology, Bone and Bones diagnostic imaging, Computer-Aided Design, Imaging, Three-Dimensional, Multidetector Computed Tomography
- Abstract
This study introduces a standardized protocol for conducting linear measurements of postcranial skeletal elements using three-dimensional (3D) models constructed from post-mortem computed tomography (PMCT) scans. Using femoral DICOM datasets, reference planes were generated and plane-to-plane measurements were conducted on 3D surface rendered models. Bicondylar length, epicondylar breadth, anterior-posterior (AP) diameter, medial-lateral (ML) diameter and cortical area at the midshaft were measured by four observers to test the measurement error variance and observer agreement of the protocol (n=6). Intra-observer error resulted in a mean relative technical error of measurement (%TEM) of 0.11 and an intraclass correlation coefficient (ICC) of 0.999 (CI=0.998-1.000); inter-observer error resulted in a mean %TEM of 0.54 and ICC of 0.996 (CI=0.979-1.000) for bicondylar length. Epicondylar breadth, AP diameter, ML diameter and cortical area also yielded minimal error. Precision testing demonstrated that the approach is highly repeatable and is recommended for implementation in anthropological investigation and research. This study exploits the benefits of virtual anthropology, introducing an innovative, standardized alternative to dry bone osteometric measurements., (Copyright © 2017 Elsevier B.V. All rights reserved.)
- Published
- 2017
- Full Text
- View/download PDF
44. A cadaveric biomechanical study comparing the ease of femoral nail insertion: 1.0- vs 1.5-m bow designs.
- Author
-
Yuan H, Acklin Y, Varga P, Gueorguiev B, Windolf M, Epari D, Schuetz M, and Schmutz B
- Subjects
- Biomechanical Phenomena, Cadaver, Equipment Failure, Humans, Materials Testing, Models, Anatomic, Tomography, X-Ray Computed methods, Bone Nails adverse effects, Bone Nails classification, Femoral Fractures surgery, Femur diagnostic imaging, Femur surgery, Fracture Fixation, Intramedullary adverse effects, Fracture Fixation, Intramedullary instrumentation, Fracture Fixation, Intramedullary methods
- Abstract
Introduction: Anatomic fit of intramedullary nails was suggested by previous studies to improve significantly when the nail radius of curvature (ROC) is closer to the average femoral anatomy. However, no attempt has been made to investigate the impact of different ROC designs on the nail insertion process. Therefore, this biomechanical study quantitatively compared the ease of insertion between femoral intramedullary nails with a 1.0-m and a 1.5-m bow radius., Materials and Methods: Long TFN-ADVANCED™ (TFNA, 1.0 m ROC) and Proximal Femoral Nail Antirotation nails (PFNA, 1.5 m ROC) were implanted pairwise into seven paired cadaver femora. All bones were reamed 1.5 mm larger than the nail diameter. Using a material testing machine, intramedullary nailing was then performed stepwise with 20-mm steps and a 10-mm/s insertion rate, and force was measured. The nail deformation caused by the insertion was assessed through 3D computer models built from pre- and post-nailing CT scans. The ease of insertion between TFNA and PFNA nails was quantified in terms of insertion force, insertion energy and nail deformation., Results: There was no significant difference in the peak force generated during nailing between TFNA and PFNA nails (P = 0.731). However, the force measured at the end of insertion (P = 0.002) was significantly smaller in TFNA nails compared to PFNA nails. After implantation, TFNA nails showed significantly smaller deformation when compared to PFNA nails (P = 0.005, both ends aligned). Furthermore, less energy was required to insert TFNA nails; however, the difference was not significant (P = 0.25)., Conclusions: Compared to PFNA nails, a significant decrease in insertion force and nail deformation was found at the end of insertion for TFNA nails. Results suggest that TFNA having a 1.0-m ROC is easier to insert for the set of femora used in this study compared to PFNA with a 1.5-m ROC.
- Published
- 2017
- Full Text
- View/download PDF
45. 3D Computer graphical anatomy study of the femur: a basis for a new nail design.
- Author
-
Schmutz B, Kmiec S Jr, Wullschleger ME, Altmann M, and Schuetz M
- Subjects
- Aged, Aged, 80 and over, Anthropometry, Asian People, Diaphyses anatomy & histology, Diaphyses surgery, Female, Femur anatomy & histology, Femur surgery, Femur Head anatomy & histology, Femur Head diagnostic imaging, Femur Head surgery, Femur Neck anatomy & histology, Femur Neck diagnostic imaging, Femur Neck surgery, Humans, Linear Models, Male, Tomography, X-Ray Computed, White People, Bone Nails, Diaphyses diagnostic imaging, Equipment Design, Femur diagnostic imaging, Fracture Fixation, Intramedullary instrumentation, Hip Fractures diagnostic imaging
- Abstract
Background: Current intramedullary nails with a radius of curvature (ROC) of 1500-2000 mm sometimes cause distal anterior cortical encroachment. Furthermore, clinical data indicate that the proximal nail end is too long for some Asian patients. The objective of our study was to develop a comprehensive 3D measurement protocol that measures both the anatomy of the canal and the proximal region. The protocol was used to obtain measurements from Caucasian and Asian (Japanese and Thai) specimens., Materials and Methods: A total of 90 3D bone models representative of hip fracture patients were reconstructed from CT data. RapidForm 2006 was used to generate the reference geometries required for determining radius and angulation of shaft antecurvature as well as measurements of the proximal anatomy. Multiple linear regression analyses were used to determine the relative contribution of height, age, ethnicity, gender, and body side on the total variance., Results: The mean ROC in the natural 3D antecurvature plane was 885 mm overall, 974 mm in Caucasians and 787 mm in Asians. Height, age, ethnicity, gender, and body side significantly predicted ROC (R = 0.53, p = 0.000). The mean values of anteversion measurements for Asians (Japanese: 22.1°; Thai: 22.7°) were significantly larger than those of the Caucasians (14.5°; p = 0.001). There was virtually no difference (p = 0.186) between the measurements pertaining to the length of the proximal nail end between Caucasian and Asian samples. There was no significant difference between the mean neck-to-shaft angles (Caucasian: 126°; Japanese: 128.2°; Thai: 125.7°; p = 0.198 for Asians vs Caucasians)., Conclusions: The developed comprehensive anatomical 3D measurement protocol could serve as standardised approach for anthropometric studies in the future. Our data suggest that the ROC of current nail designs should be reduced from between 1500 and 2000 to 1000 mm to achieve an improved fit for the investigated population.
- Published
- 2017
- Full Text
- View/download PDF
46. Can MRI accurately detect pilon articular malreduction? A quantitative comparison between CT and 3T MRI bone models.
- Author
-
Radzi S, Dlaska CE, Cowin G, Robinson M, Pratap J, Schuetz MA, Mishra S, and Schmutz B
- Abstract
Background: Pilon fracture reduction is a challenging surgery. Radiographs are commonly used to assess the quality of reduction, but are limited in revealing the remaining bone incongruities. The study aimed to develop a method in quantifying articular malreductions using 3D computed tomography (CT) and magnetic resonance imaging (MRI) models., Methods: CT and MRI data were acquired using three pairs of human cadaveric ankle specimens. Common tibial pilon fractures were simulated by performing osteotomies to the ankle specimens. Five of the created fractures [three AO type-B (43-B1), and two AO type-C (43-C1) fractures] were then reduced and stabilised using titanium implants, then rescanned. All datasets were reconstructed into CT and MRI models, and were analysed in regards to intra-articular steps and gaps, surface deviations, malrotations and maltranslations of the bone fragments., Results: Initial results reveal that type B fracture CT and MRI models differed by ~0.2 (step), ~0.18 (surface deviations), ~0.56° (rotation) and ~0.4 mm (translation). Type C fracture MRI models showed metal artefacts extending to the articular surface, thus unsuitable for analysis. Type C fracture CT models differed from their CT and MRI contralateral models by ~0.15 (surface deviation), ~1.63° (rotation) and ~0.4 mm (translation)., Conclusions: Type B fracture MRI models were comparable to CT and may potentially be used for the postoperative assessment of articular reduction on a case-to-case basis., Competing Interests: Dr. Schmutz has received an industrial scholarship from Synthes GmBH. The other authors have no conflicts of interest to declare.
- Published
- 2016
- Full Text
- View/download PDF
47. Quantification of cephalomedullary nail fit in the femur using 3D computer modelling: a comparison between 1.0 and 1.5m bow designs.
- Author
-
Schmutz B, Amarathunga J, Kmiec S Jr, Yarlagadda P, and Schuetz M
- Subjects
- Aged, Aged, 80 and over, Computer Simulation, Female, Femoral Fractures diagnostic imaging, Fracture Fixation, Intramedullary methods, Humans, Imaging, Three-Dimensional methods, Male, Prosthesis Design, Prosthesis Fitting methods, Software, Tomography, X-Ray Computed methods, Bone Nails, Femoral Fractures surgery, Fracture Fixation, Intramedullary instrumentation, Models, Anatomic
- Abstract
Background: The radius of curvature (ROC) misfit of cephalomedullary nails during anterograde nailing can lead to complications such as distal anterior cortical encroachment. This study quantified the anatomical fit of a new nail with 1.0-m ROC (TFN-ADVANCED(™) Proximal Femoral Nailing System [TFNA]) compared with a nail with 1.5-m ROC (Gamma3 Long Nail R1.5 [Gamma3])., Methods: We generated 63 three-dimensional models (48 female, 45 right femur) representing the cortical surfaces of the femora (31 Caucasian, 28 Japanese, and 4 Thai). The mean age of the specimens was 77 years (±8.1), and the mean height was 158.5 cm (±9.6). Utilizing a customized software tool, nail fit was determined from the total surface area of nail protrusion from the inner cortex surface and maximum distance of nail protrusion in the axial plane; the position of the distal nail tip within the canal was also determined., Results: Overall, TFNA had both a significantly smaller mean total surface area of nail protrusion (915.8 vs. 1181.6 mm(2); P < 0.05) and a mean maximum distance of nail protrusion in the axial plane (1.9 vs. 2.1 mm; P = 0.007) when compared with Gamma3. The mean total surface area of nail protrusion was significantly smaller with TFNA versus Gamma3 in both the Caucasian (P = 0.0009) and Asian (Japanese and Thai) samples (P = 0.000002); the mean maximum distance of TFNA protrusion was significantly smaller in Asians (P = 0.04), but not in Caucasians (P = 0.08). Most tip positions for both nail types were anterior, but TFNA had a higher number of center positions than Gamma3 (13 vs. 7) and a shift from the far anterior cortex to the center of the medullary canal (overall and in Caucasians). In Asians, the most prominent position was far anterior for both nails., Conclusions: The 1.0-m ROC TFNA nail resulted in better fit than the 1.5-m ROC Gamma3 nail. Clinical trials and case studies should be conducted in the future to verify if these findings would also result in clinical improvements.
- Published
- 2016
- Full Text
- View/download PDF
48. Can we safely deform a plate to fit every bone? Population-based fit assessment and finite element deformation of a distal tibial plate.
- Author
-
Harith H, Schmutz B, Malekani J, Schuetz MA, and Yarlagadda PK
- Subjects
- Adult, Aged, Aged, 80 and over, Female, Humans, Male, Middle Aged, Prosthesis Failure, Bone Plates, Finite Element Analysis, Mechanical Phenomena, Prosthesis Design, Tibia surgery
- Abstract
Anatomically precontoured plates are commonly used to treat periarticular fractures. A well-fitting plate can be used as a tool for anatomical reduction of the fractured bone. Recent studies highlighted that some plates fit poorly for many patients due to considerable shape variations between bones of the same anatomical site. While it is impossible to design one shape that fits all, it is also burdensome for the manufacturers and hospitals to produce, store and manage multiple plate shapes without the certainty of utilization by a patient population. In this study, we investigated the number of shapes required for maximum fit within a given dataset, and if they could be obtained by manually deforming the original plate. A distal medial tibial plate was automatically positioned on 45 individual tibiae, and the optimal deformation was determined iteratively using finite element analysis simulation. Within the studied dataset, we found that: (i) 89% fit could be achieved with four shapes, (ii) 100% fit was impossible through mechanical deformation, and (iii) the deformations required to obtain the four plate shapes were safe for the stainless steel plate for further clinical use. The proposed framework is easily transferable to other orthopaedic plates., (Copyright © 2015 IPEM. Published by Elsevier Ltd. All rights reserved.)
- Published
- 2016
- Full Text
- View/download PDF
49. Automated fit quantification of tibial nail designs during the insertion using computer three-dimensional modelling.
- Author
-
Amarathunga JP, Schuetz MA, Yarlagadda PK, and Schmutz B
- Subjects
- Adult, Aged, Computer Simulation, Equipment Failure Analysis methods, Female, Fracture Fixation, Intramedullary methods, Humans, Imaging, Three-Dimensional methods, In Vitro Techniques, Male, Middle Aged, Models, Biological, Prosthesis Design methods, Reproducibility of Results, Sensitivity and Specificity, Software, Stress, Mechanical, Tibial Fractures physiopathology, Treatment Outcome, Bone Nails, Fracture Fixation, Intramedullary instrumentation, Prosthesis Fitting methods, Surgery, Computer-Assisted methods, Tibial Fractures surgery
- Abstract
Intramedullary nailing is the standard fixation method for displaced diaphyseal fractures of the tibia. An optimal nail design should both facilitate insertion and anatomically fit the bone geometry at its final position in order to reduce the risk of stress fractures and malalignments. Due to the nonexistence of suitable commercial software, we developed a software tool for the automated fit assessment of nail designs. Furthermore, we demonstrated that an optimised nail, which fits better at the final position, is also easier to insert. Three-dimensional models of two nail designs and 20 tibiae were used. The fitting was quantified in terms of surface area, maximum distance, sum of surface areas and sum of maximum distances by which the nail was protruding into the cortex. The software was programmed to insert the nail into the bone model and to quantify the fit at defined increment levels. On average, the misfit during the insertion in terms of the four fitting parameters was smaller for the Expert Tibial Nail Proximal bend (476.3 mm(2), 1.5 mm, 2029.8 mm(2), 6.5 mm) than the Expert Tibial Nail (736.7 mm(2), 2.2 mm, 2491.4 mm(2), 8.0 mm). The differences were statistically significant (p ≤ 0.05). The software could be used by nail implant manufacturers for the purpose of implant design validation., (© IMechE 2014.)
- Published
- 2014
- Full Text
- View/download PDF
50. Metal artifacts from titanium and steel screws in CT, 1.5T and 3T MR images of the tibial Pilon: a quantitative assessment in 3D.
- Author
-
Radzi S, Cowin G, Robinson M, Pratap J, Volp A, Schuetz MA, and Schmutz B
- Abstract
Radiographs are commonly used to assess articular reduction of the distal tibia (pilon) fractures postoperatively, but may reveal malreductions inaccurately. While magnetic resonance imaging (MRI) and computed tomography (CT) are potential three-dimensional (3D) alternatives they generate metal-related artifacts. This study aims to quantify the artifact size from orthopaedic screws using CT, 1.5T and 3T MRI data. Three screws were inserted into one intact human cadaver ankle specimen proximal to and along the distal articular surface, then CT, 1.5T and 3T MRI scanned. Four types of screws were investigated: titanium alloy (TA), stainless steel (SS) (Ø =3.5 mm), cannulated TA (CTA) and cannulated SS (CSS) (Ø =4.0 mm, Ø empty core =2.6 mm). 3D artifact models were reconstructed using adaptive thresholding. The artifact size was measured by calculating the perpendicular distance from the central screw axis to the boundary of the artifact in four anatomical directions with respect to the distal tibia. The artifact sizes (in the order of TA, SS, CTA and CSS) from CT were 2.0, 2.6, 1.6 and 2.0 mm; from 1.5T MRI they were 3.7, 10.9, 2.9, and 9 mm; and 3T MRI they were 4.4, 15.3, 3.8, and 11.6 mm respectively. Therefore, CT can be used as long as the screws are at a safe distance of about 2 mm from the articular surface. MRI can be used if the screws are at least 3 mm away from the articular surface except for SS and CSS. Artifacts from steel screws were too large thus obstructed the pilon from being visualised in MRI. Significant differences (P<0.05) were found in the size of artifacts between all imaging modalities, screw types and material types, except 1.5T versus 3T MRI for the SS screws (P=0.063). CTA screws near the joint surface can improve postoperative assessment in CT and MRI. MRI presents a favourable non-ionising alternative when using titanium hardware. Since these factors may influence the quality of postoperative assessment, potential improvements in operative techniques should be considered.
- Published
- 2014
- Full Text
- View/download PDF
Catalog
Discovery Service for Jio Institute Digital Library
For full access to our library's resources, please sign in.