2. Successful percutaneous embolization of an intraoperative swan ganz catheter-related pulmonary artery injury
- Author
-
Pranav Suri, BS and Charles Kitley, MD
- Subjects
Embolization ,Pseudoaneurysm ,Pulmonary artery ,Swan Ganz catheter ,Medical physics. Medical radiology. Nuclear medicine ,R895-920 - Abstract
Intraoperative pulmonary artery injury due to Swan Ganz catheterization is a rare but potentially life-threatening injury which demands rapid recognition and treatment. Subsequent pseudoaneurysm formation can occur if not immediately recognized, and percutaneous embolization is a viable option for treatment in most settings. We report a case of a 59-year-old female who underwent coronary artery bypass surgery and suffered an intraoperative Swan Ganz catheter-related injury which led to life threatening hemorrhage with subsequent pulmonary artery pseudoaneurysm formation that was successfully embolized. This case report is pathognomonic for this injury and discusses risk factors, presentation, and treatment options of this rare but serious injury.
- Published
- 2022
- Full Text
- View/download PDF
3. Right heart catheterization in idiopathic pulmonary hypertension: An all-inclusive necessity.
- Author
-
Adhyapak, Srilakshmi M., Konda, Abhilash, K T, Thirumal, Shivakumar, and Varghese, Kiron
- Abstract
The gold standard for diagnosis of pulmonary hypertension is right heart catheterization. This procedure requires considerable expertise and has its own procedure related complications. If not done properly, it can lead to misinterpretations of its findings. We have highlighted the procedural technique and major pitfalls in the diagnosis of pulmonary hypertension. [ABSTRACT FROM AUTHOR]
- Published
- 2024
- Full Text
- View/download PDF
4. Right Heart Catheterization
- Author
-
Madias, Christopher, Kimmelstiel, Carey, Hendel, Robert C., editor, and Kimmelstiel, Carey, editor
- Published
- 2017
- Full Text
- View/download PDF
5. Chest radiographs of cardiac devices (Part 1): Lines, tubes, non-cardiac medical devices and materials
- Author
-
Rishi P. Mathew, Timothy Alexander, Vimal Patel, and Gavin Low
- Subjects
Chest radiographs ,endotracheal tube ,tracheostomy tube ,nasogastric tube ,central venous catheter ,Swan Ganz catheter ,intercostal drainage tube. ,Medical physics. Medical radiology. Nuclear medicine ,R895-920 - Abstract
Chest radiographs (CXRs) are the most common imaging investigations undertaken because of their value in evaluating the cardiorespiratory system. They play a vital role in intensive care units for evaluating the critically ill. It is therefore very common for the radiologist to encounter tubes, lines, medical devices and materials on a daily basis. It is important for the interpreting radiologist not only to identify these iatrogenic objects, but also to look for their accurate placement as well as for any complications related to their placement, which may be seen either on the immediate post-procedural CXR or on a follow-up CXR. In this article, we discussed and illustrated the routinely encountered tubes and lines that one may see on a CXR as well as some of their complications. In addition, we also provide a brief overview of other important non-cardiac medical devices and materials that may be seen on CXRs.
- Published
- 2019
- Full Text
- View/download PDF
6. Chest radiographs of cardiac devices (Part 1): Lines, tubes, non-cardiac medical devices and materials.
- Author
-
Mathew, Rishi P., Alexander, Timothy, Patel, Vimal, and Low, Gavin
- Subjects
CHEST X rays ,CLINICAL competence ,CRITICALLY ill ,FOREIGN bodies ,IATROGENIC diseases ,INTENSIVE care units ,PATIENTS ,RISK assessment ,SURGICAL complications ,TRACHEOTOMY equipment ,MEDICAL equipment reliability ,CENTRAL venous catheters ,SWAN-Ganz catheterization ,ENDOTRACHEAL tubes ,MEDICAL drainage ,NASOENTERAL tubes ,RADIOGRAPHY - Abstract
Chest radiographs (CXRs) are the most common imaging investigations undertaken because of their value in evaluating the cardiorespiratory system. They play a vital role in intensive care units for evaluating the critically ill. It is therefore very common for the radiologist to encounter tubes, lines, medical devices and materials on a daily basis. It is important for the interpreting radiologist not only to identify these iatrogenic objects, but also to look for their accurate placement as well as for any complications related to their placement, which may be seen either on the immediate post-procedural CXR or on a follow-up CXR. In this article, we discussed and illustrated the routinely encountered tubes and lines that one may see on a CXR as well as some of their complications. In addition, we also provide a brief overview of other important non-cardiac medical devices and materials that may be seen on CXRs. [ABSTRACT FROM AUTHOR]
- Published
- 2019
- Full Text
- View/download PDF
7. CORRELATION OF PULMONARY CAPILLARY WEDGE PRESSURE CALCULATED BY ECHO-DOPPLER WITH INVASIVE MEASUREMENT BY SWAN GANZ CATHETER IN POST CORONARY ARTERY BYPASS GRAFT PATIENTS
- Author
-
Falguni Ghosh Roy, G.R. Kane, Harshad Rajge, and Keshav Kale
- Subjects
medicine.medical_specialty ,medicine.anatomical_structure ,business.industry ,Internal medicine ,cardiovascular system ,medicine ,Cardiology ,business ,Pulmonary wedge pressure ,Swan Ganz Catheter ,Echo doppler ,circulatory and respiratory physiology ,Artery - Abstract
The present study was conducted to correlate PCWP estimated by Doppler Echocardiography with that obtained by Swan-Ganz catheter in patients with post coronary artery bypass graft surgery and to evaluate the feasibility and accuracy of Doppler Echocardiographic data. The present study provides evidence that in patients with coronary artery disease who underwent elective CABG surgery, PCWP can be reliably and accurately estimated by combining Doppler Echocardiographic variables of mitral flow and Tissue Doppler imaging and the relationship between E/Ea ratio and measured PCWP by Swan Ganz catheter was the strongest of all Doppler variables determined.
- Published
- 2021
- Full Text
- View/download PDF
8. Alveolopleural Fistula In COVID-19 Treated with Bronchoscopic Occlusion with a Swan-Ganz Catheter
- Author
-
Aleksey Tagintsev, Evan Schmitz, Nathaniel z Hitt, and Douglas Summerfield
- Subjects
medicine.medical_specialty ,bronchoscopy ,treatment ,Coronavirus disease 2019 (COVID-19) ,pneumothorax ,R5-130.5 ,RC86-88.9 ,business.industry ,Fistula ,persistent air leak ,Medical emergencies. Critical care. Intensive care. First aid ,medicine.disease ,bronchial occlusion ,Swan Ganz Catheter ,Surgery ,alveolopleural fistula ,sars-cov-2 ,covid-19 ,General works ,Occlusion ,medicine ,pulmonary artery catheter ,business ,swan-ganz catheter - Abstract
Pneumothorax and pneumomediastinum are known complications of COVID-19 patients. They have been documented to occur both with and without mechanical ventilation. There are several reports of cases further complicated by alveolopleural or bronchopleural fistulas. However, there are no studies and only a few case reports on the treatment options used for alveolopleural fistulas in COVID-19 patients. To our knowledge, there is only one report of bronchoscopic treatment with endobronchial valves in a COVID-19 patient. We present the case of a 63-year-old male with COVID-19, pneumothorax, and an alveolopleural fistula that was successfully sealed using bronchoscopic occlusion with a Swan-Ganz catheter.
- Published
- 2021
- Full Text
- View/download PDF
9. Does the Use of a Pulmonary Artery Catheter Make a Difference During or After Cardiac Surgery?
- Author
-
Joseph, Corey, Garrubba, Marie, Melder, Angela, and Smith, Julian A.
- Subjects
- *
CARDIAC surgery , *INTENSIVE care units , *MORTALITY , *PATIENTS , *CORONARY artery bypass , *PULMONARY artery catheters , *CATASTROPHIC illness , *PATIENT monitoring , *POSTOPERATIVE period , *PULMONARY artery , *SURGICAL therapeutics , *SYSTEMATIC reviews , *SWAN-Ganz catheterization , *THERAPEUTICS - Abstract
Pulmonary artery catheters (PACs) were introduced in 1970. Since then, their use has steadily increased. However, there have been questions raised regarding their efficacy for multiple clinical scenarios. The purpose of this systematic review was to determine the safety and effectiveness of routine use of PACs post cardiac surgery on mortality, complications, days in intensive care unit, days in hospital, and costs in patients undergoing cardiac surgery, or patients who end up in an intensive care unit.
Methods: Medline, All EBM, EMBASE and Cumulative Index to Nursing and Allied Health Literature (CINAHL) databases were searched using predetermined search terms. Google, British Medical Journal (BMJ) Best Practice, and the National Institute for Clinical Excellence (NICE) were also searched. All searches were from 2012 to current to update a previous review from 2013. Studies were included if they involved adult cardiac surgery patients, or intensive care unit (ICU) patients requiring haemodynamic monitoring. All other surgical patients were excluded.Results: Six articles were included in this review. Of the six articles, five were randomised or observational studies, and one was an expert recommendation. For all cardiac surgery patients and patients having coronary artery bypass grafting, there was no difference in mortality. There was an increase in mortality in high-risk cardiac surgery patients, who had a PAC. For patients following coronary artery bypass grafting, there was no difference in ICU length of stay (LOS) but for patients following cardiac surgery total length of hospital stay >30days was greater in patients with a PAC. For patients following coronary artery bypass grafting, in-hospital costs for the entire hospitalisation were higher in patients with a PAC and, there was no difference in complications between PAC and a central venous catheter use. Overall, PACs were not a predictor of worse outcomes.Conclusion: This review revealed that PAC use was associated with a poorer outcome in a small subset of cardiac surgical patients but in the majority of patients PAC use made no difference to outcome. Further studies are required to confirm the true safety and efficacy of PAC use in cardiac surgery. [ABSTRACT FROM AUTHOR]- Published
- 2018
- Full Text
- View/download PDF
10. Akzidentelle Fixierung eines Pulmonalarterienkatheters während einer Herztransplantation
- Author
-
Stefan Bleiler and Andreas Holzamer
- Subjects
Gynecology ,ddc:610 ,medicine.medical_specialty ,business.industry ,610 Medizin ,030208 emergency & critical care medicine ,General Medicine ,Swan Ganz Catheter ,03 medical and health sciences ,0302 clinical medicine ,Anesthesiology and Pain Medicine ,Heart surgery, Swan-Ganz catheter, Suture, Fluoroscopy, Resternotomy ,030202 anesthesiology ,medicine ,business - Abstract
Inadvertent fixation of a Swan-Ganz pulmonary artery catheter by a suture is a rare complication. We present a case report of a patient undergoing heart transplantation in whom the catheter was fixed by a suture at the upper venous cannulation site for the cardiopulmonary bypass. After diagnostics with fluoroscopy the chest was reopened and the suture was released. The catheter could then be removed. The patient did not suffer from any consequential damage. Die akzidentelle Fixierung eines Pulmonalarterienkatheters durch eine Naht ist eine seltene Komplikation. Dieser Fall handelt von einem Patienten zur Herztransplantation, bei dem der Katheter mittels Naht an der oberen venösen Kanülierungsstelle der Herz-Lungen-Maschine fixiert wurde. Nach Diagnostik mittels Fluoroskopie erfolgten die Resternotomie und die Lösung der Naht, woraufhin sich der Katheter entfernen ließ. Der Patient trug keine Folgeschäden davon.
- Published
- 2020
- Full Text
- View/download PDF
11. Tricuspid valve Swan‐Ganz catheter entrapment before cardiac surgery
- Author
-
Sébastien Colombier, V. Rancati, Lars Niclauss, J. Lavanchy, Carlo Marcucci, and Matthias Kirsch
- Subjects
medicine.medical_specialty ,Tricuspid valve ,business.industry ,Energy Engineering and Power Technology ,Case Report ,Transoesophageal echocardiography ,Swan Ganz Catheter ,Cardiac surgery ,Surgery ,Catheter ,Coronary artery bypass surgery ,Entrapment ,Fuel Technology ,medicine.anatomical_structure ,Surgical removal ,medicine ,business - Abstract
A Swan‐Ganz catheter during cardiac surgery offers peri‐operative haemodynamic monitoring, although insertion of these catheters is not without risk. We report a case of Swan‐Ganz catheter entrapment within the tricuspid valve during elective off‐pump coronary artery bypass surgery. The diagnosis was made immediately by transoesophageal echocardiography, thus preventing forced withdrawal of the catheter. Intra‐operatively, the echocardiographically detected findings of complex entrapment was confirmed. The Swan‐Ganz catheter was tightly wrapped around the subvalvular apparatus, requiring on‐pump open surgical removal. This case illustrates the anatomical complexity of such a catheter entrapment around the tricuspid valve apparatus and the importance of rapid echocardiographic diagnosis to prevent iatrogenic damage.
- Published
- 2020
- Full Text
- View/download PDF
12. Non-invasive assessment of central venous pressure in heart failure: a systematic prospective comparison of echocardiography and Swan-Ganz catheter
- Author
-
Angelika Costard-Jäckle, Henrik Fox, Odile Sauzet, Jan Gummert, Lech Paluszkiewicz, M Potratz, Tobias Szymczyk, and Volker Rudolph
- Subjects
Adult ,Male ,medicine.medical_specialty ,Central Venous Pressure ,Diastole ,Hemodynamics ,Vena Cava, Inferior ,030204 cardiovascular system & hematology ,Inferior vena cava ,Ventricular Function, Left ,Swan Ganz Catheter ,03 medical and health sciences ,0302 clinical medicine ,Predictive Value of Tests ,Mitral valve ,Internal medicine ,medicine ,Humans ,Radiology, Nuclear Medicine and imaging ,Prospective Studies ,030212 general & internal medicine ,Aged ,Heart Failure ,Original Paper ,Ejection fraction ,business.industry ,Central venous pressure ,Reproducibility of Results ,Middle Aged ,medicine.disease ,medicine.anatomical_structure ,medicine.vein ,Echocardiography ,Catheterization, Swan-Ganz ,Heart failure ,cardiovascular system ,Ventricular Function, Right ,Cardiology ,Female ,Right-heart catheterization ,Cardiology and Cardiovascular Medicine ,business - Abstract
Assessing hemodynamics, especially central venous pressure (CVP), is essential in heart failure (HF). Right heart catheterization (RHC) is the gold-standard, but non-invasive methods are also needed. However, the role of 2-dimensional echocardiography (2DE) remains uncertain, and 3-dimensional echocardiography (3DE) is not always available. This study investigated standardized and breathing-corrected assessment of inferior vena cava (IVC) volume using echocardiography (2DE and 3DE) versus CVP determined invasively using RHC. Sixty consecutive HF patients were included (82% male, age 54 ± 11 years, New York Heart Association class 2.23 ± 0.8, ejection fraction 46 ± 18.4%, brain natriuretic peptide 696.93 ± 773.53 pg/mL). All patients underwent Swan-Ganz RHC followed by 2DE and 3DE, and IVC volume assessment. On 2DE, mean IVC size was 18.3 ± 5.5 mm and 13.8 ± 6 mm in the largest deflection and shortest distention, respectively. Mean CVP from RHC was 9.3 ± 5.3 mmHg. Neither 2DE nor 3DE showed acceptable correlation with invasively measured CVP; IVC volume acquisition showed optimal correlation with RHC CVP (0.64; 95% confidence interval 0.46–0.77), with better correlation when mitral valve early diastole E wave and right ventricular end-diastolic diameter were added. Using a CVP cut-point of 10 mmHg, receiver operating characteristic curve showed true positivity (specificity) of 0.90 and sensitivity of 62% for predicting CVP. A validation study confirmed these findings and verified the high predictive value of IVC volume assessment. Neither 2DE nor 3DE alone can reliably mirror CVP, but IVC volume acquisition using echocardiography allows non-invasive and adequate approximation of CVP. Correlation with invasively measured pressure was strongest when CVP is > 10 mmHg.
- Published
- 2020
- Full Text
- View/download PDF
13. Narrative History of the Swan-Ganz Catheter: Development, Education, Controversies, and Clinician Acumen
- Author
-
Thomas Ahrens and Jan M. Headley
- Subjects
Development education ,medicine.medical_specialty ,Catheters ,medicine.medical_treatment ,Nursing Staff, Hospital ,030204 cardiovascular system & hematology ,Critical Care Nursing ,History, 21st Century ,Swan Ganz Catheter ,03 medical and health sciences ,0302 clinical medicine ,medicine ,Humans ,030212 general & internal medicine ,Intensive care medicine ,Monitoring, Physiologic ,Critically ill ,business.industry ,Narrative history ,Pulmonary artery catheter ,General Medicine ,History, 20th Century ,Catheter ,Catheterization, Swan-Ganz ,Emergency Medicine ,Clinical Competence ,business - Abstract
The year 2020 marks the 50th anniversary of the landmark publication on the bedside clinical use of a flow-directed catheter. The catheter, now known as the Swan-Ganz catheter, truly revolutionized practice and care of the critically ill. Use of the catheter proliferated nearly without rigorous validation or evidence base until a moratorium was called in regard to its use. This article describes the history of the development of the Swan-Ganz catheter, its uses, and its near downfall. The authors, both involved in educating clinicians in the use of the pulmonary artery catheter, hope that telling this story shares tribal knowledge and lessons learned with newer generations of nurses who did not experience the explosion of development and knowledge in the area of hemodynamic monitoring. Partly because of advances in technology, and the catheter’s application for heart failure in particular, use of the pulmonary catheter is being resurrected.
- Published
- 2020
- Full Text
- View/download PDF
14. Mixed Shock States: A Case for the Pulmonary Artery Catheter
- Author
-
Paul Thurman
- Subjects
medicine.medical_specialty ,Cardiac output ,medicine.medical_treatment ,Hemodynamics ,Critical Care Nursing ,Swan Ganz Catheter ,Fatal Outcome ,Internal medicine ,medicine.artery ,medicine ,Humans ,In patient ,Aged ,Pulmonary Arterial Hypertension ,business.industry ,Pulmonary artery catheter ,Shock ,General Medicine ,medicine.disease ,Catheterization, Swan-Ganz ,Shock (circulatory) ,Heart failure ,Practice Guidelines as Topic ,Pulmonary artery ,Emergency Medicine ,Cardiology ,Female ,medicine.symptom ,business - Abstract
The pulmonary artery catheter is a valuable tool available to the clinician for use in deciphering complex hemodynamic scenarios. Patients in shock, particularly those who are elderly or have premorbid conditions such as heart failure, may have atypical presentations. Additional hemodynamic data may help identify interventions that might seem counterintuitive, such as the use of vasoconstrictors in patients with low cardiac output. Interpretation of pulmonary artery hemodynamic data is a skill that should not be relegated to the past. This article reviews the use of a pulmonary artery catheter in mixed shock states. A case study is used to demonstrate how pulmonary artery catheter hemodynamic values can guide the care of these patients.
- Published
- 2020
- Full Text
- View/download PDF
15. A guide to performing a right heart catheterization examination: Indication pulmonary hypertension
- Author
-
Hollaus, Victoria
- Subjects
Hämodynamische Messungen ,Rechtsherzkatheter ,Swan Ganz Katheter ,pulmonary hypertension ,swan ganz catheter ,right heart catheterization ,Pulmonale Hypertonie ,hemodynamic measurements - Abstract
Die Rechtsherzkatheteruntersuchung im Herzkatheterlabor ist von Bedeutung, um den Schweregrad der pulmonalen Hypertonie zu erfassen, sowie die Diagnose zu bestätigen. Das Ziel dieser Arbeit ist, einen Einblick in die Versorgung von Patient*innen im Rechtsherzkatheter bei der Indikation einer pulmonalen Hypertonie zu bieten. Der Leitfaden beschreibt jeden Prozessschritt einer Rechtsherzkatheteruntersuchung und beinhaltet einen detailliert dargestellten Workflow. Mit Hilfe von Recherchen in Datenbanken, wie beispielsweise PubMed und ScienceDirect, stützt sich diese Bachelorarbeit auf wissenschaftlich fundierte Quellen. Zudem wird das Wissen der empirischen Arbeit aus medizinischen Studien und Fachbüchern gewonnen, um so eine vielseitige Grundlage der Argumentation zu gewährleisten. Der Publikationszeitraum beinhaltet die Jahre 2016 bis 2021. In dieser Bachelorarbeit kommt englische, sowie deutsche Literatur zur Anwendung. Die Magnetresonanztomographie kann als potenzielle Ersatztechnik zum Rechtsherzkatheter bei der Diagnosestellung einer pulmonalen Hypertonie dienen. Korrekte hämodynamische Messungen während einer Rechtsherzkatheteruntersuchung sind von Bedeutung, um Fehldiagnosen zu vermeiden. Dazu zählt die korrekte Nullpunkteinstellung, Durchführung der Messungen am Ende der Exspiration, sowie die Bestimmung des Herzzeitvolumens mit der geeigneten Methode. In der klinischen Routine sollte die Thermodilutionsmethode, gegenüber der Methode nach Fick bevorzugt werden. Als bevorzugte Zugangsstelle sollte der venöse Zugang über die Ellenbeuge gewählt werden. Da die meisten Komplikationen im Zusammenhang mit dem femoralen Zugang auftreten, sollte dieser Zugangsweg, nach Möglichkeit, vermieden werden. Die Rechtsherzkatheteruntersuchung kann unabhängig vom Alter der Patient*innen zur Diagnosestellung einer pulmonalen Hypertonie zum Einsatz kommen. Anzumerken ist, dass die hausinternen Standards, wie die Nahrungskarenz oder Blutprobenwerte, variieren können. Auf dem 6th World Symposium on pulmonary Hypertension 2018 wurde die Definition der pulmonalen Hypertonie als Ruhe PAPm > 20 mmHg vorgeschlagen, im Unterschied zur bestehenden Definition der ESC/ERS Leitlinie 2015 von PAPm ≥ 25 mmHg. Right heart catheterization in the catheterization laboratory is essential to register the severity of pulmonary hypertension and to further confirm the diagnosis. The aim of this thesis is to give an overview of the treatment of patients with pulmonary hypertension in the catherization laboratory. This paper covers the entire process of the right heart catheterization, moreover, a detailed Workflow is included. The research is approached using several medical databases, such as PubMed and ScienceDirect. In addition, books, as well as German and English studies, that were published between 2016 and 2021, are used. MRI can potentially serve as alternative technique for right heart catheterization in the diagnosis of pulmonary hypertension. Correct hemodynamic measurements during a right heart catheterization are significant to avoid misdiagnosis. This includes the correct zero point setting, carrying out the measurements at the end of expiration, as well as the determination of the HZV with the appropriate method, depending on the clinical scenario. Regarding the diagnosis of pulmonary hypertension, the antecubital venous access should be the preferred access side for right heart catheterization for the diagnosis of pulmonary hypertension. Most complications occur in combination with the femoral access. Therefore, this access should be avoided if possible. Right heart catheterization can be examined regardless of the patients` age for the diagnosis of pulmonary hypertension. In this context it should be mentioned that the procedure of right heart catheterization can be implemented differently depending on in-house standards, such as blood values or fasting. At the 6th World Symposium 2018 on Pulmonary Hypertension, the definition of pulmonary hypertension as rest PAPm > 20 mmHg was proposed, in contrast to the existing definition of the ESC/ERS guideline 2015 of PAPm ≥ 25 mmHg.
- Published
- 2022
16. Pulmonary artery pseudoaneurysm as a Swan-Ganz catheter complication
- Author
-
Aurora Díaz Valdecantos, and César Carrascosa Rosillo, Laura Gallego López, and Nuria Miranda Balbuena
- Subjects
medicine.medical_specialty ,business.industry ,macromolecular substances ,medicine.disease ,Swan Ganz Catheter ,Surgery ,Pseudoaneurysm ,medicine.artery ,Pulmonary artery ,cardiovascular system ,Medicine ,cardiovascular diseases ,Cardiology and Cardiovascular Medicine ,Complication ,business - Abstract
To the Editor, We present the case of a 65-year-old woman without any known drug allergies and with a previous cardiac history of atrial fibrillation treated with warfarin and rheumatic poly-valve disease with double mitral valve lesion (severe mitral stenosis and moderate-to-severe mitral regurgitation) and severe tricuspid regurgitation with indirect data of pulmonary hypertension admitted due to progressive worsening of her usual dyspnea until becoming dyspnea of minimal exertion and with important limitations in activities of daily living.
- Published
- 2021
- Full Text
- View/download PDF
17. Incremental experience in optimizing in vitro primary culture of human pulmonary arterial endothelial cells harvested from Swan-Ganz catheters
- Author
-
Birger Tielemans, Rozenn Quarck, Catharina Belge, Leanda Stoian, Mathias Leys, Marion Delcroix, and Allard Wagenaar
- Subjects
Primary culture ,business.industry ,Anesthesia ,Medicine ,business ,Swan Ganz Catheter - Published
- 2021
- Full Text
- View/download PDF
18. A novel technique for invasive aortic valve pressure gradient measurement using a 6 Fr Swan-Ganz catheter: a case series
- Author
-
Ahmed N. Mahmoud, Nayan Agarwal, Deepak L. Bhatt, and Ujjwal Rastogi
- Subjects
Novel technique ,Aortic valve ,medicine.medical_specialty ,Aorta ,business.industry ,Aortic stenosis ,Swan-Ganz ,Dual lumen catheter ,Case Report ,medicine.disease ,Swan Ganz Catheter ,Stenosis ,Catheter ,medicine.anatomical_structure ,Ventricle ,Internal medicine ,medicine.artery ,medicine ,Cardiology ,AcademicSubjects/MED00200 ,Cardiology and Cardiovascular Medicine ,business ,Case series ,Pressure gradient - Abstract
Background Simultaneous left ventricular (LV) and aortic (Ao) pressure gradient assessment has been rendered challenging since the recall of the Langston catheter. Here we describe a simple method for simultaneous LV and Ao pressure gradient assessment using a Swan-Ganz catheter. Case summary We describe two cases where assessment of simultaneous left ventricle and Ao valve gradients was done using a Swan-Ganz catheter to assess the degree of Ao stenosis and dynamic LV outflow obstruction. Discussion Using Swan-Ganz catheter assessment of simultaneous left ventricle and Ao valve gradients can simplify the procedure with reduced cost and increased patient safety.
- Published
- 2021
19. Perforation of the left ventricle wall due to the insertion of a pulmonary artery catheter. A case report
- Author
-
B. Quintana-Villamandos, P. Benito-Saz, J. Hortal, L. Fernandez-Quero, A. Garrido, and J.M. Barrio
- Subjects
medicine.medical_specialty ,business.industry ,medicine.medical_treatment ,Perforation (oil well) ,Pulmonary artery catheter ,Hemodynamics ,General Medicine ,030204 cardiovascular system & hematology ,Swan Ganz Catheter ,03 medical and health sciences ,Patient safety ,0302 clinical medicine ,medicine.anatomical_structure ,Internal medicine ,medicine.artery ,Pulmonary artery ,medicine ,Cardiology ,030212 general & internal medicine ,Interventricular septum ,business ,Complication - Abstract
Despite the widespread and frequent use in our setting of pulmonary artery catheters for haemodynamic management in critically ill patients, particularly after heart surgery, some experts continue to question the need for these devices. Clinicians need to weigh up the risks and benefits of pulmonary artery catheters placement and bear in mind the potential complications which, though rare, can be potentially fatal. We present a pulmonary artery catheters-related complication not hitherto described in the literature, involving perforation of the interventricular septum and left ventricular free wall caused by a kink in the pulmonary artery catheters that was not suspected, and only diagnosed by direct vision of the heart after pericardial opening. In the interest of patient safety, we must consider the impact of adverse events; improving our situational awareness and our understanding of the mechanisms behind such events can help reduce the likelihood of repetitions in the future.
- Published
- 2019
- Full Text
- View/download PDF
20. Comparison Between Swan-Ganz Catheter and Minimally Invasive Hemodynamic Monitoring During Liver Transplantation: Report of a Monocentric Case Series
- Author
-
Giuditta Fallabrino, Renato Manzi, Federico Piccioni, England Hila, Alessandro Germini, Martina Pagano, Federico Sodi, Alessandro Villa, Daniela Codazzi, Franco Valenza, and Vincenzo Mazzaferro
- Subjects
Male ,medicine.medical_specialty ,medicine.medical_treatment ,Liver transplantation ,Swan Ganz Catheter ,Coronary artery disease ,Liver disease ,Monitoring, Intraoperative ,medicine ,Humans ,Minimally Invasive Surgical Procedures ,Retrospective Studies ,Transplantation ,business.industry ,Hemodynamic Monitoring ,Pulmonary artery catheter ,Retrospective cohort study ,Middle Aged ,medicine.disease ,Liver Transplantation ,Surgery ,Catheter ,Catheterization, Swan-Ganz ,Portal hypertension ,Female ,business - Abstract
The aim of the present investigation was to retrospectively evaluate the utilization of Swan-Ganz catheter during orthotopic liver transplantation as opposed to FloTrac/Vigileo in selected cases, comparing a number of clinical outcomes across postoperative hospitalization.Before 2015 all recipients received pulmonary artery catheter (Swan-Ganz group, n = 109). After 2015 Swan-Ganz was used only if coronary artery disease or high-grade portal hypertension or Child-Pugh C were present; the remaining recipients were assigned to FloTrac/Vigileo monitoring (Mini group, n =100). A number of clinical outcomes were considered.Donor's Risk Index was similar between groups (median value 1.7, P = .27). Anthropometric characteristics of the recipients were similar in the 2 groups. There were no significant differences in the proportion of patients with Child-Pugh C (P = .873), coronary artery disease (P = .18), and grade of portal hypertension (P = .733). The Model for End-Stage Liver Disease score was slightly higher in the Mini group: (9 [7-11] vs 9 [8-12], Swan-Ganz vs Mini, respectively, P .035). Swan-Ganz utilization decreased over time (92% vs 26%, Swan-Ganz vs Mini, P .001). Upon admission to the intensive care unit, patients of the Mini group presented a higher SAPS II score with similar values of Sequential Organ Failure Assessment score. Days on mechanical ventilation were similar between groups. The incidence of graft failure was similar between groups (2% vs 5%, Swan-Ganz and Mini group respectively, P = .376). Recipients' hospital length of stay was similar (13 days [11-19] vs 14 [11-20], P .083).Our data suggest that the intraoperative utilization of FloTrac/Vigileo for oncologic patients with low grade end stage liver disease is reasonably safe.
- Published
- 2019
- Full Text
- View/download PDF
21. Pacing Swan-Ganz Catheter in Minimally Invasive Mitral Valve Surgery
- Author
-
Edmund Donahue, Ricardo Levin, Ignacio Rios, Michael Pitracek, and Carlos Ruano
- Subjects
Mitral valve repair ,medicine.medical_specialty ,Cox maze procedure ,business.industry ,medicine.medical_treatment ,Mitral valve replacement ,Swan Ganz Catheter ,Surgery ,Catheter ,Left atrial ,Heart rate ,medicine ,business ,Mitral valve surgery - Abstract
espanolIntroduccion: La cirugia mediante mini-toracotomia lateral presenta ventajas comparativas sobre el acceso convencional comomenor trauma quirurgico, reducida morbimortalidad y un resultado estetico superior, pero plantea dificultades en caso denecesitar estimulacion electrica temporal.Objetivo: Valorar el empleo terapeutico del cateter de Swan-Ganz con marcapasos incorporado como solucion a dicho problemay analizar sus complicaciones.Material y metodos: Se incluyeron pacientes programados para cirugia mini-invasiva mitral mediante mini-toracotomia lateral.Se definio empleo terapeutico del cateter al uso debido a bradiarritmias o trastornos de conduccion o necesidad de incrementarla frecuencia cardiaca con fines hemodinamicos. Pacientes intervenidos de urgencia o emergencia, fueron excluidos del estudio.Resultados: Fueron incluidos 517 pacientes (289 de sexo masculino, con edad promedio de 68,3 ± 10,4 anos); se efectuaron 115(22,2%) reemplazos y 402 (77,7%) plasticas mitrales. Simultaneamente, se realizaron 294 (56,9%) procedimientos de Maze, 182(35,2%) cierres de orejuela izquierda, 9 (1,7%) cierres de defectos septales y 14 (2,7%) plasticas tricuspideas. Ciento sesenta ydos (313%) pacientes necesitaron ser marcapaseados; debido a bradiarritmias, 85 (52,47%) pacientes; por trastornos de conduccion,50 (30,86%) pacientes; mientras que otros 27 (16,66%) requirieron incrementar su frecuencia debido a bajo volumenminuto. La mortalidad resulto de 12 (2,32%) casos. Catorce (2,7%) pacientes presentaron perdida de captura y se resolvieroncon el reposicionamiento del cateter, mientras que 2 (0,6%) pacientes presentaron atrapamiento y requirieron reintervencion.Conclusiones: Casi un tercio de los pacientes intervenidos mediante mini-toracotomia lateral requirieron del empleo terapeuticodel cateter de Swan-Ganz con marcapasos. Dos pacientes presentaron atrapamiento y requirieron resolucion quirurgica. EnglishThe use of a lateral mini-thoracotomy presents several advantages over the standard access, such as less surgical trauma, reduced morbidity and mortality, shorter recovery time and better cosmetic results, but presents difficulties iftemporary pacing is required.Objective: The aim of this study was to evaluate the therapeutic use of a Swan-Ganz catheter with pacing capabilities andanalyze its complications.Methods: Patients undergoing scheduled minimally invasive mitral valve surgery through lateral mini-thoracotomy wereincluded in the study. Therapeutic use of the pacing catheter was defined as the need for pacing due to bradyarrhythmiasor conduction disorders or need of increasing heart rate in case of hemodynamic instability. Patients undergoing urgent oremergency surgery were excluded from the study.Results: A total of 517 patients were included in the study; mean age was 68.3 ± 10.4 years and 289 (55.9%) were men; 115 patients(22.2%) underwent mitral valve replacement and 402 (77.7%) mitral valve repair. The following concomitant procedureswere carried out: 294 (56.9%) Maze procedures, 182 (35.2%) left atrial appendage closures, 9 (1.7%) atrial septal defect closuresand 14 (2.7%) tricuspid valve repair surgeries. In the postoperative period 162 (31.3%) patients required pacing due to bradyarrhythmiasin 85 cases (52.47%), conduction disorders in 50 (30.86%), and need to increase heart rate in 27 (16.66%) patientswith low cardiac output syndrome. Postoperative mortality was 2.32% (n=12). Fourteen (2.7%) patients presented loss of capturethat was resolved with catheter repositioning, while 2 (0.6%) patients presented catheter entrapment requiring reintervention.Conclusion: Almost one-third of the patients undergoing lateral mini-thoracotomy required therapeutic use of the pacingSwan-Ganz catheter. Two patients presented catheter entrapment and required surgical reintervention
- Published
- 2019
- Full Text
- View/download PDF
22. Intra-operative temperature monitoring with two non-invasive devices (3M Spoton® and Dräger Tcore®) in comparison with the Swan-Ganz catheter
- Author
-
F.E. Fernández-Suárez, N. García-González, M. Estrada-Martínez, F.J. Gómez-Romero, D. Cachero-Martínez, C. Gutiérrez-González, J F Navarro-Gracia, M.D. Picatto-Hernández, Carmen Martínez-Ortega, Maria Fernández-Prada, and S. Suárez-Fernández
- Subjects
Core (anatomy) ,Accuracy and precision ,medicine.medical_specialty ,Correlation coefficient ,business.industry ,lcsh:R ,lcsh:Surgery ,lcsh:Medicine ,030208 emergency & critical care medicine ,lcsh:RD1-811 ,Spearman's rank correlation coefficient ,Confidence interval ,Swan Ganz Catheter ,Cardiac surgery ,03 medical and health sciences ,Catheter ,0302 clinical medicine ,030202 anesthesiology ,Medicine ,Surgery ,Cardiology and Cardiovascular Medicine ,business ,Nuclear medicine - Abstract
Background: The measurement of core body temperature in the pulmonary artery (Swan-Ganz catheter) is regarded as the reference standard. Nowadays, new non-invasive methods of measuring core temperature have emerged, such as the 3M SpotOn® and the Dräger Tcore® sensor. Methods: A cross-sectional descriptive study was conducted on patients undergoing scheduled cardiac surgery. Both devices, and the Swan-Ganz catheter, were simultaneously evaluated. The correlation of temperature values was measured using the intra-class correlation coefficient and Spearman's rank or Pearson correlation analysis. The repeated-measurements version of the Bland and Altman test were used to determine the level of agreement. Results: A total of 289 measurements were made. Analysis of Spearman rank correlation between the Swan-Ganz catheter and 3M SpotOn® pair yielded a correlation coefficient (r) of 0.82 [95% confidence interval (95% CI); 0.77–0.85, p
- Published
- 2019
23. A Tale of Serendipity, Ingenuity, and Chance
- Author
-
James S. Forrester
- Subjects
Psychoanalysis ,business.industry ,Serendipity ,media_common.quotation_subject ,030204 cardiovascular system & hematology ,Swan Ganz Catheter ,03 medical and health sciences ,0302 clinical medicine ,Ingenuity ,Medicine ,030212 general & internal medicine ,Cardiology and Cardiovascular Medicine ,business ,Swan ganz ,media_common ,Intuition - Abstract
On the 50th anniversary of the invention of the Swan-Ganz catheter, the untold, intimate details of its development deserve recounting, in part because it illustrates how often advances in science require equal measures of brilliant intuition, persistence in adversity, stunning serendipity, plain
- Published
- 2019
- Full Text
- View/download PDF
24. Safety and Patients’ Response to Ambulation With a Pulmonary Artery Catheter in the Cardiac Intensive Care Unit
- Author
-
Bienvenido Tabuzo, Marjorie Funk, Liberty Reyes, Elisa Mattioli, Prasama Sangkachand, and Janet Parkosewich
- Subjects
Adult ,Male ,Critical Care ,medicine.medical_treatment ,Walking ,Pulmonary Artery ,030204 cardiovascular system & hematology ,Critical Care Nursing ,Severity of Illness Index ,Swan Ganz Catheter ,law.invention ,03 medical and health sciences ,0302 clinical medicine ,Heart Rate ,law ,medicine.artery ,Heart rate ,medicine ,Humans ,Longitudinal Studies ,Prospective Studies ,030212 general & internal medicine ,Fatigue ,Aged ,Heart Failure ,business.industry ,Pulmonary artery catheter ,General Medicine ,Middle Aged ,medicine.disease ,Intensive care unit ,Intensive Care Units ,Catheter ,Catheterization, Swan-Ganz ,Heart failure ,Anesthesia ,Pulmonary artery ,Coronary care unit ,Female ,business - Abstract
Background Early mobilization of patients in the intensive care unit can be beneficial, but evidence is insufficient to indicate whether allowing patients with an indwelling pulmonary artery catheter to walk is safe. Objective To describe the physiological and emotional responses to ambulation in patients with heart failure and a pulmonary artery catheter. Methods This prospective, descriptive study included 19 patients with heart failure monitored with a pulmonary artery catheter in a cardiac intensive care unit. Each patient, accompanied by a nurse, walked with continuous observation of heart rate and rhythm and pulmonary artery tracing on a transport monitor. Pulmonary artery catheter position and waveform, arrhythmias, and perceived levels of exertion and fatigue were recorded before and after each walk. The distance ambulated was documented. One to 3 times per week, nurses administered a questionnaire addressing patients’ sense of well-being. Results The 19 patients had 303 walks (range, 1–68; median, 7). During 7 patient walks (2.4%), catheter migration of 1 to 5 cm occurred, but no arrhythmias or waveform changes were observed. Changes in exertion and fatigue were significant (P < .001, paired t test), but levels of both were minimal after walking. Patients expressed physical and emotional benefits of walking. Conclusions This study provides preliminary evidence that for hemodynamically stable patients with heart failure, ambulating with a pulmonary artery catheter is safe and enhances their sense of well-being. The presence of an indwelling pulmonary artery catheter should not preclude walking.
- Published
- 2019
- Full Text
- View/download PDF
25. Automatic detection Using Deep Convolutional Neural Networks for 11 Abnormal Positioning of Tubes and Catheters in Chest X-ray Images
- Author
-
Abdelfettah Elaanba, Larbi Hassouni, and Mohammed Ridouani
- Subjects
Adult patients ,business.industry ,Computer science ,X ray image ,CAD ,Image processing ,Computer vision ,Artificial intelligence ,business ,Convolutional neural network ,Swan Ganz Catheter ,Computer aided detection ,Endotracheal tube - Abstract
Tubes and Catheters are very important devices for saving patients' lives. There is a variety of tubes and Catheters; those especially used during this study are: Endotracheal tube (ETT), Nasogastric (NG)], and Swan Ganz catheter. Errors in positioning these kinds of devices, if not detected early my caused crucial complications (even death). Airway tube malposition in adult patients intubated is seen in up to 25% of cases. Doctors and nurses use checklists to make sure the medical procedure goes smoothly, but these steps take a long time and more resources with the possibility of human errors during verification protocols especially when hospitals are at full capacity. In this article, we propose using transfer learning to train and compare several Keras applications on classification tube problems; the best-selected networks can help in the development of CAD (Computer Aided Detection). The main advantage of using a single Deep Convolutional Neural Network DCNN to detect abnormal positioning of several lines based on chest X-ray image processing is to avoid the complexity caused by using a DCNN (Deep Convolutional Neural Network) network for each type of line. Efficient DCNN can detect abnormal positioning in real-time and immediately notify doctors to adjust tube position. All tested networks during this work are improved after augmentations and parameters tuning, we get the best score for Resnet50V2 model AUC (80%).
- Published
- 2021
- Full Text
- View/download PDF
26. Comparing doppler-echocardiography and thermodilution for cardiac output measurements in resuscitated out-of-hospital cardiac arrest patients undergoing targeted temperature management
- Author
-
Jacob E. Møller, John Bro-Jeppesen, Christian Hassager, Jesper Kjaergaard, and Johannes Grand
- Subjects
Coma ,Resuscitation ,Cardiac output ,medicine.medical_specialty ,medicine.diagnostic_test ,19.5 - Cardiac Arrest ,business.industry ,medicine.medical_treatment ,General Medicine ,Targeted temperature management ,Doppler echocardiography ,Critical Care and Intensive Care Medicine ,Intensive care unit ,Swan Ganz Catheter ,law.invention ,law ,Internal medicine ,Cardiology ,Medicine ,Bland–Altman plot ,medicine.symptom ,Cardiology and Cardiovascular Medicine ,business - Abstract
Funding Acknowledgements Type of funding sources: None. Background Cardiovascular dysfunction is common after out-of-hospital cardiac arrest (OHCA). Cardiac output measurements can be used to guide treatment during post-resuscitation care and echocardiography allows noninvasive cardiac output estimation. Purpose The aim of the present study was to compare Doppler echocardiography (doppler_CO) with thermodilution using pulmonary artery catheters (PAC_CO) for cardiac output estimation in a large and consecutively included cohort of comatose OHCA-patients undergoing targeted temperature management (TTM). Methods Single-center substudy of 171 patients included in the TTM-trial randomly assigned to 33 or 36 degrees C for 24 hours after OHCA. We measured PAC_CO and doppler_CO simultaneously shortly after admission and again after 24 hours. Measurements and Main Results We excluded 19 (11%) patients without PAC-measurement and 31 (18%) without doppler-measurements resulting in 120 paired measurements at admission. Patients were 61 (±11) years old, 86% were men and 91% had a witnessed OHCA. At ICU-admission, PAC_CO was 4.81 (±1.81) L/min. and doppler_CO was 3.74 (±1.38) L/min., with a mean bias of 1.07 (±1.65) L/min (with 95% limits of agreement of –2.16 to 4.04) L/min. Examining the Bland-Altman plot, precision fell with higher cardiac output (figure). A statistically significant, but moderate correlation was found between doppler_CO and PAC_CO at admission (r = 0.49), p < 0.0001). After 24 hours, PAC_CO was 4.63 (±1.38) L/min. and doppler_CO was 3.61 (±1.14) L/min, with a mean bias of 0.96 L/min. Assessing the change from admission to 24 hours, PAC_CO decreased averagely -0.12 (±2.22) L/min. and doppler_CO decreased -0.19 (±1.91) L/min. The changes from admission to 24 hours correlated between doppler_CO and PAC_CO (r = 0.55), p < 0.0001) with a mean bias of the changes of 0.07 L/min, with 95% limits of agreement of –3.76 to 3.91 L/min. Conclusions Changes in cardiac output during TTM may be evaluated with Doppler echocardiography with little mean bias compared to changes in CO measured with thermodilution, but relatively large changes are needed in the individual patient before it can be considered as real. Abstract Figure. Comparing Doppler vs. thermodilution
- Published
- 2021
27. Alternative methods to assess cardiac index: different parameters for physicians when swan-ganz catheter is not available
- Author
-
A Cimatti, M Blanco, R Iamevo, S Mrad, and H Cohen Arazi
- Subjects
Alternative methods ,medicine.medical_specialty ,Cardiac output ,Ejection fraction ,business.industry ,Cardiac index ,General Medicine ,Critical Care and Intensive Care Medicine ,Swan Ganz Catheter ,Cardiac Surgery procedures ,16.6 - Clinical ,Critical illness ,Emergency medicine ,Invasive hemodynamic monitoring ,Medicine ,Cardiology and Cardiovascular Medicine ,business - Abstract
Funding Acknowledgements Type of funding sources: Private hospital(s). Main funding source(s): Sanatorium Mitre Introduction invasive hemodynamic monitoring with Swan-Ganz catheter (SGC) has been the gold standard to determine the cardiac index. However, in many centres is not always available, and the Fick method is also validated for that purpose, but without the same accuracy. There are other used laboratory parameters; nonetheless there is lack of evidence about its association with the cardiac index. We aim to describe the association between these parameters and the patient"s hemodynamic condition. Objectives to assess the association between hemodynamic parameters obtained by SGC and data obtained with a jugular central venous catheter, in critically ill cardiac patients hospitalised in the Intensive Care Unit. Methods prospective, double-blind, observational study, conducted from September 2019 to November 2020. A total of 45 patients with SGC were enrolled. We measured cardiac output and cardiac index (by thermodilution method and Fick estimated method), other hemodynamic parameters, lactic acid, central venous oxygen saturation (CVO2) and venous-to-arterial carbon dioxide difference (VACO2). The variables were analysed with t-test, Wilcoxon and chi2, as appropriate. Statistical significance was assumed when p was less than .05. Results we analysed 45 patients (mean age 58 years; 87% men; 23% postoperative cardiac surgery subjects; mean ejection fraction 30%). We registered a 6% in-hospital mortality and the mean in-hospital stay was 19 days (IQR 25-75: 8-25). We observed a significative correlation between impaired cardiac index (≤2.2 L/min/m2) obtained by SGC and Fick method (r 0.43; p= .0041). Elevated lactic acid and reduced CVO2 were not well correlated with impaired cardiac index (r 0.51, CI 95%: 0.32-0.71; r 0.30, CI 95%: 0.13-0.48; respectively). Among patients with impaired cardiac index, all of them had a VACO2 over 7 mmHg. The c-statistic to predict impaired cardiac index using VACO2 over 7 mmHg was 0.66 (CI 95%: 0.48-0.84), correlation not observed for the CVO2 values. Elevated lactic acid (≤1.9 mmol/L) was only associated with noradrenaline infusion over 0.7 g/kg/min (c-statistic 0.55; p= .0002). Conclusions when invasive hemodynamic monitoring with SGC is not available, the VACO2 value over 7 mmHg (obtained with a central venous catheter) appeared to be a better predictor of impaired cardiac index than the determination of CVO2. The Fick method was an acceptable replacement of the invasive monitoring. Also, noradrenaline infusion over 0.7 g/kg/min, but not cardiac index or other laboratory parameters, showed a better correlation with elevated lactic acid.
- Published
- 2021
- Full Text
- View/download PDF
28. Percutaneous removal of a knotted Swan–Ganz catheter
- Author
-
Soichiro Enomoto, Hirokazu Kondo, Makoto Miyake, Toshihiro Tamura, Yodo Tamaki, and Hibiki Mima
- Subjects
medicine.medical_specialty ,Catheters ,Percutaneous ,medicine.diagnostic_test ,business.industry ,General surgery ,Interventional radiology ,General Medicine ,Swan Ganz Catheter ,Catheterization, Swan-Ganz ,medicine ,Humans ,Radiology, Nuclear Medicine and imaging ,Cardiology and Cardiovascular Medicine ,business ,Device Removal - Published
- 2021
- Full Text
- View/download PDF
29. PERCUTANEOUS RETRIEVAL OF THE SUTURE-ENTRAPPED SWAN-GANZ CATHETER
- Author
-
Amir Sarkeshik, David Li, Roger Goldman, and Bob Kiaii
- Subjects
Pulmonary and Respiratory Medicine ,medicine.medical_specialty ,Percutaneous ,Suture (anatomy) ,business.industry ,medicine ,Cardiology and Cardiovascular Medicine ,Critical Care and Intensive Care Medicine ,business ,Swan Ganz Catheter ,Surgery - Published
- 2021
- Full Text
- View/download PDF
30. Agreement between continuous and intermittent pulmonary artery thermodilution for cardiac output measurement in perioperative and intensive care medicine: a systematic review and meta-analysis
- Author
-
Moritz Flick, Karim Kouz, Alina Bergholz, Gerhard Schön, Frederic Michard, Phillip Hoppe, Christina Vokuhl, Bernd Saugel, and Luisa Briesenick
- Subjects
Pulmonary artery catheterization ,medicine.medical_specialty ,Cardiac output ,Critical Care ,Thermodilution ,Cardiac index ,Pulmonary Artery ,Critical Care and Intensive Care Medicine ,Swan Ganz Catheter ,03 medical and health sciences ,Cardiac output measurement ,0302 clinical medicine ,Hemodynamic monitoring ,030202 anesthesiology ,Internal medicine ,medicine.artery ,medicine ,Humans ,Right heart catheterization ,Cardiac Output ,Indicator dilution method ,Swan-Ganz catheter ,business.industry ,Research ,lcsh:Medical emergencies. Critical care. Intensive care. First aid ,030208 emergency & critical care medicine ,lcsh:RC86-88.9 ,Perioperative ,Pooled variance ,Catheterization, Swan-Ganz ,Meta-analysis ,Pulmonary artery ,Cardiology ,business ,Cardiovascular dynamics - Abstract
Background Pulmonary artery thermodilution is the clinical reference method for cardiac output monitoring. Because both continuous and intermittent pulmonary artery thermodilution are used in clinical practice it is important to know whether cardiac output measurements by the two methods are clinically interchangeable. Methods We performed a systematic review and meta-analysis of clinical studies comparing cardiac output measurements assessed using continuous and intermittent pulmonary artery thermodilution in adult surgical and critically ill patients. 54 studies with 1522 patients were included in the analysis. Results The heterogeneity across the studies was high. The overall random effects model-derived pooled estimate of the mean of the differences was 0.08 (95%-confidence interval 0.01 to 0.16) L/min with pooled 95%-limits of agreement of − 1.68 to 1.85 L/min and a pooled percentage error of 29.7 (95%-confidence interval 20.5 to 38.9)%. Conclusion The heterogeneity across clinical studies comparing continuous and intermittent pulmonary artery thermodilution in adult surgical and critically ill patients is high. The overall trueness/accuracy of continuous pulmonary artery thermodilution in comparison with intermittent pulmonary artery thermodilution is good (indicated by a pooled mean of the differences PROSPERO registration number CRD42020159730.
- Published
- 2021
- Full Text
- View/download PDF
31. Pulmonary tumor embolism from breast cancer diagnosed by selective aspiration cytology using a Swan-Ganz catheter
- Author
-
Hiroshi Mannoji, Toyoshi Yanagihara, Ryohei Aoki, Syunya Sunami, Reiko Yoneda, Nobuhiro Tsuruta, and Makoto Usui
- Subjects
Pulmonary and Respiratory Medicine ,medicine.medical_specialty ,medicine.diagnostic_test ,RC705-779 ,business.industry ,medicine.medical_treatment ,Cancer ,Case Report ,Malignancy ,medicine.disease ,Scintigraphy ,Pulmonary tumor thrombotic microangiopathy ,Swan Ganz Catheter ,Pulmonary embolism ,Catheter ,Diseases of the respiratory system ,Breast cancer ,Pulmonary wedge aspiration cytology ,medicine ,Swan-ganz catheter ,Radiology ,business ,Mastectomy ,Pulmonary tumor embolism - Abstract
We describe a case of pulmonary tumor embolism (PTE) from breast cancer diagnosed by selective aspiration cytology using a Swan-Ganz catheter. A 60-year-old woman was referred to Hamanomachi Hospital because of increased levels of tumor markers. The patient complained only of slight exertional dyspnea and a dry cough. Due to breast cancer, she had undergone a mastectomy followed by radiation and chemotherapy one year earlier. Positron emission tomography scanning with CT images revealed no evidence of malignancy. Repeated chest CT images showed emerging wedge-shaped nodules in the subpleural zones of the left lower lobe with diffuse ground-glass opacities in the bilateral lower lobes. The D-dimer level was negative. Pulmonary perfusion scintigraphy showed multiple small wedge-shaped defect areas on the peripheral sides of the bilateral lungs. Suspecting PTE, we performed selective aspiration cytology from the left pulmonary arteries. Cancer cells were detected from selected branches of left A8 and A9. Morphology and immunostaining led to a final diagnosis of PTE of recurrent breast cancer. Pulmonary embolism of cancer is a progressive, fatal condition with challenging diagnosis. Selective aspiration cytology with a Swan-Ganz catheter is a useful, less invasive option in patients with suspected PTE.
- Published
- 2021
32. Bedside ultrasound assessments of jugular venous compliance to track central venous pressure change during the treatment of decompensated heart failure
- Author
-
Marc A. Simon, W Lambert, S Fatima, John J. Pacella, and S Nouraie
- Subjects
medicine.medical_specialty ,Acute decompensated heart failure ,business.industry ,Cost effectiveness ,Central venous pressure ,Hemodynamics ,medicine.disease ,Swan Ganz Catheter ,Compliance (physiology) ,Internal medicine ,Heart failure ,medicine ,Cardiology ,Cardiology and Cardiovascular Medicine ,business ,Internal jugular vein - Abstract
Background Accurate volume status assessment is crucial for the treatment of acute decompensated heart failure (ADHF). Volume status assessment by physical exam is inaccurate, necessitating invasive measurement with right heart catheterization (RHC), which carries safety, pragmatic (scheduling, holding anticoagulants, etc) and financial burdens. Therefore, a reliable, non-invasive, cost-effective alternative is desired. Previously, we developed an ultrasound (US) based technique to measure internal jugular vein (IJV) compliance during RHC which was used for single time point central venous pressure (CVP) predictions. We now aim to apply this technique to track acute changes in CVP during diuresis for ADHF in patients with an in-dwelling pulmonary artery catheter. Purpose The objective of our study was to devise a rapid, portable and reliable alternative to RHC to track acute volume changes during treatment of ADHF. Methods We used an observational, prospective study design and recruited 15 patients from the CCU between 7/19–12/19 being treated for ADHF (systolic or diastolic) with IV diuretics +/−inotropic agents who underwent PA catheter insertion for continuous CVP monitoring. 13 of 15 patients received milrinone infusions. US images of the IJV were obtained at end expiration and during the strain phase of Valsalva at multiple 2–3 hr intervals. Change in IJV cross sectional area (ImageJ) was used as a measure of IJV compliance. Patients unable to perform the Valsalva maneuver and on mechanical circulatory support were excluded. Results Calculated % change in CSA of IJV was plotted against CVP. An inverse relationship was observed between CVP and % change in CSA of IJV. The data was fit with an inverse exponential regression shown in Figure 1 (R2=0.36, root mean square error = 3.19). Fivefold cross validation showed a stable model for predicting CVP based CSA (R2=0.34, root mean square error = 3.26) Conclusion Serial portable US assessment of IJV compliance can act a surrogate measure of CVP and,therefore, can provide reliable information on acute hemodynamic changes in ADHF. Funding Acknowledgement Type of funding source: None
- Published
- 2020
- Full Text
- View/download PDF
33. Difficult removal: a Swan-Ganz catheter coiled on the central venous catheter
- Author
-
He Huang, Jian Shen, and Luyao Ma
- Subjects
Adult ,Pulmonary and Respiratory Medicine ,medicine.medical_specialty ,Vena Cava, Superior ,Percutaneous ,medicine.medical_treatment ,lcsh:Surgery ,Case Report ,030204 cardiovascular system & hematology ,Swan Ganz Catheter ,lcsh:RD78.3-87.3 ,03 medical and health sciences ,0302 clinical medicine ,Superior vena cava ,medicine ,Central Venous Catheters ,Humans ,Cardiac Surgical Procedures ,Difficult removal ,Device Removal ,Swan-Ganz catheter ,business.industry ,X-Rays ,Hemodynamics ,lcsh:RD1-811 ,General Medicine ,Surgery ,Cardiac surgery ,Radiography ,Catheter ,030228 respiratory system ,lcsh:Anesthesiology ,Cardiothoracic surgery ,Catheterization, Swan-Ganz ,Fluoroscopy ,Introducer sheath ,Female ,Cardiology and Cardiovascular Medicine ,business ,Complication ,Central venous catheter - Abstract
Background The Swan-Ganz catheter plays an important role in gaining understanding of cardiac pathophysiology and in the hemodynamic monitoring of critically ill patients. Difficult removal of the Swan-Ganz catheter is a rare but serious complication. Case presentation This case presents the difficult removal of a Swan-Ganz catheter in a 28-year-old female patient after cardiac surgery. Fluoroscopy and chest X-ray revealed that a portion of the Swan-Ganz catheter was coiled on the central venous catheter at the level of the superior vena cava. Under X-ray guidance, the central venous catheter was first removed, and then the Swan-Ganz catheter was successfully withdrawn through the percutaneous introducer sheath. Conclusions This case report provides an unreported reason for difficult removal and describes a successful solution. This report suggests that X-ray examinations may be necessary before removing the Swan-Ganz catheter.
- Published
- 2020
- Full Text
- View/download PDF
34. Swan-Ganz catheter causing anaphylactic shock: A rare case report
- Author
-
Muhammad U Asghar, Krishna Kommineni, Sanwal Singh Mehta, and Hira A Cheema
- Subjects
inorganic chemicals ,Allergy ,business.industry ,Public Health, Environmental and Occupational Health ,Case Report ,Critical Care and Intensive Care Medicine ,medicine.disease ,Balloon ,Anaphylactic shock ,Swan Ganz Catheter ,Catheter ,Intensive care ,Shock (circulatory) ,Anesthesia ,Rare case ,Emergency Medicine ,cardiovascular system ,Medicine ,heterocyclic compounds ,medicine.symptom ,business ,Swan-Ganz catheter - Abstract
Latex-induced anaphylactic reactions are often underestimated in patients having procedures in a catheterization lab, intensive care units, or in operating rooms. Most physicians are not aware that almost all balloons in the Swan-Ganz catheter (SGC) are made up of latex. Direct exposure of these latex balloons in the blood can cause severe anaphylactic reactions, even in patients with no previous history of allergies. We present a case of a 53-year-old male, who underwent a SGC placement for cardiovascular evaluation. Immediately after the SGC insertion, he developed circulatory shock. On further investigation, we discovered that SGC balloon contained latex as one of the components. Physicians should be aware of latex-based products such as SGC balloon, which can cause anaphylactic shock even in case of no prior allergies to latex.
- Published
- 2019
35. Assessing Transvalvular Aortic Gradient With Swan-Ganz Catheter
- Author
-
Jalaj Garg, Salman Allana, and Sudhi Tyagi
- Subjects
medicine.medical_specialty ,Catheters ,Aortic valve gradient ,business.industry ,Pulmonary Artery ,Swan Ganz Catheter ,Treatment Outcome ,Catheterization, Swan-Ganz ,Internal medicine ,Cardiology ,medicine ,Humans ,Cardiology and Cardiovascular Medicine ,business ,Aorta - Published
- 2021
- Full Text
- View/download PDF
36. IS THE SWAN-GANZ CATHETER EXCLUSIVELY A TOOL FOR PRESSURE MEASUREMENTS INSIDE THE PULMONARY CIRCULATION? THE MECHANICAL CONTRIBUTION OF THE PULMONARY ARTERY CATHETER TO A CRITICAL DECISION MAKING INTRAOPERATIVELY
- Author
-
Konstantinos Lolakos, Anda-Cristina Butnar, Nikolaos Tsotsolis, Isaak Keremidis, Nikolaos Nikoloudakis, Antonios Pitsis, and Timotheos Kelpis
- Subjects
medicine.medical_specialty ,business.industry ,medicine.medical_treatment ,Central venous pressure ,Pulmonary artery catheter ,Inferior vena cava ,Swan Ganz Catheter ,Pulmonary vein ,Anesthesiology and Pain Medicine ,medicine.vein ,Superior vena cava ,Internal medicine ,medicine.artery ,Pulmonary artery ,medicine ,Cardiology ,Arterial line ,Cardiology and Cardiovascular Medicine ,business - Abstract
Introduction The Pulmonary Artery Catheter (PAC) Swan-Ganz, despite the widespread rumours regarding the possible complications that correlate with its insertion, such as the pulmonary artery rupture, is still - in the experienced hands - an essential tool of hemodynamic monitoring in cardiac surgery. In combination with Transoesophageal Echocardiography (TOE) though, they offer to the Anaesthesiologist an integrated profile of pressure, volume, flow velocity and anatomical information. However, there can still be occasions where the above mentioned hemodynamic and non-hemodynamic data are not enough to guide the surgical decision-making process intraoperatively. In this case report, we present the contribution of the difficulty in advancing the PAC into the Right Atrium (RA), as an indication of Superior Vena Cava (SVC) stenosis, and the need to return to CardioPulmonary Bypass (CPB) to repair it, during a surgery of totally endoscopic Atrial Septal Defect (ASD) closure. Methods A 40yr old female patient is undergoing totally endoscopic cardiac surgery with CPB for the closure of a Superior Sinus Venosus ASD with simultaneous anomalous drainage of the Right Upper Pulmonary Vein (RUPV) into the SVC. The anaesthetic monitoring includes arterial line, PAC and TOE, which confirms the preoperative findings (Figure 1,2,3), while for the needs of the operation the Anaesthesiologist inserts also a CPB cannula in the Right Internal Jugular Vein. Later on, during the phase that the surgeon is advancing the second venous CPB cannula through the femoral vein and the Inferior Vena Cava (IVC) into the RA, the PAC is being withdrawn from its wedge position and is left high inside the SVC, showing the Central Venous Pressure (CVP). Results After the closure of the ASD and the flow diversion of the RUPV into the Left Atrium with a bovine pericardial patch, deairing is taking place, the restoration of the ASD is being confirmed with the TOE and successful CPB weaning occurs. A subsequent TOE scan shows turbulence inside the SVC with the colour Doppler (Figure 4), indicative of stenosis, while the CVP is 15mmHg, and the dilemma that is coming up is if the stenosis is clinically significant or not. However, at the same time it is impossible to readvance the PAC into the RA, an indication of severe SVC stenosis, and the team decides to return to CPB to repair it. After the placement of a second pericardial patch that widens the RA-SVC junction on a beating heart, laminar flow is being depicted inside the SVC (Figure 5), the PAC is being seamlessly floated into the RA (Figure 6) until its wedge position, and the CVP is 8mmHg. The short and the long-term postoperative periods were uncomplicated. Discussion The intraoperative use of the PAC in the current case report, and the difficulty in readvancing it more specifically, proved to be crucial in making an undoubtedly critical decision towards repairing a stenosis that could have been overlooked, if we had simply relied on the CVP, and become even fatal in case of delayed diagnosis. The mechanical contribution of the PAC has been underlined.
- Published
- 2021
- Full Text
- View/download PDF
37. Successful percutaneous embolization of an intraoperative swan ganz catheter-related pulmonary artery injury.
- Author
-
Suri P and Kitley C
- Abstract
Intraoperative pulmonary artery injury due to Swan Ganz catheterization is a rare but potentially life-threatening injury which demands rapid recognition and treatment. Subsequent pseudoaneurysm formation can occur if not immediately recognized, and percutaneous embolization is a viable option for treatment in most settings. We report a case of a 59-year-old female who underwent coronary artery bypass surgery and suffered an intraoperative Swan Ganz catheter-related injury which led to life threatening hemorrhage with subsequent pulmonary artery pseudoaneurysm formation that was successfully embolized. This case report is pathognomonic for this injury and discusses risk factors, presentation, and treatment options of this rare but serious injury., (© 2022 The Authors. Published by Elsevier Inc. on behalf of University of Washington.)
- Published
- 2022
- Full Text
- View/download PDF
38. Troubles After Swan-Ganz Catheter Placement in Cardiac Surgery
- Author
-
Sebastiana Gregu, Paola Suriano, Valeria Mazzanti, and Camilla L'Acqua
- Subjects
medicine.medical_specialty ,business.industry ,MEDLINE ,030204 cardiovascular system & hematology ,medicine.disease ,Swan Ganz Catheter ,Surgery ,Cardiac surgery ,03 medical and health sciences ,0302 clinical medicine ,Anesthesiology and Pain Medicine ,Aneurysm ,030228 respiratory system ,medicine.artery ,Pulmonary artery ,medicine ,Cardiology and Cardiovascular Medicine ,business - Published
- 2017
- Full Text
- View/download PDF
39. Fiftieth Anniversary of the Swan-Ganz Catheter: From Then Until Now
- Author
-
Jan M. Headley
- Subjects
medicine.medical_specialty ,Critical Care ,business.industry ,General surgery ,General Medicine ,History, 20th Century ,Critical Care Nursing ,History, 21st Century ,Swan Ganz Catheter ,Catheterization, Swan-Ganz ,Emergency Medicine ,medicine ,Humans ,business ,Monitoring, Physiologic - Published
- 2020
- Full Text
- View/download PDF
40. An emerging use of the Swan–Ganz catheter: Pulmonary artery catheter delivered thrombolysis in massive pulmonary embolism
- Author
-
Abhishek Jha and Mohamed Ahmed
- Subjects
medicine.medical_specialty ,business.industry ,medicine.medical_treatment ,Pulmonary artery catheter ,General Medicine ,Thrombolysis ,medicine.disease ,Swan Ganz Catheter ,Pulmonary embolism ,Internal medicine ,medicine ,Cardiology ,Radiology, Nuclear Medicine and imaging ,Cardiology and Cardiovascular Medicine ,business - Published
- 2020
- Full Text
- View/download PDF
41. Is there still a place for the Swan‒Ganz catheter? We are not sure
- Author
-
Michael R. Pinsky, Ludhmila Abrahão Hajjar, and Daniel De Backer
- Subjects
medicine.medical_specialty ,business.industry ,General surgery ,Pain medicine ,030208 emergency & critical care medicine ,Critical Care and Intensive Care Medicine ,Swan Ganz Catheter ,03 medical and health sciences ,0302 clinical medicine ,Catheterization, Swan-Ganz ,medicine ,030212 general & internal medicine ,business ,Swan ganz - Published
- 2018
- Full Text
- View/download PDF
42. Tubes, Lines, and Catheters and Their Complications
- Author
-
Ronald L. Eisenberg
- Subjects
medicine.medical_specialty ,Vascular catheter ,business.industry ,medicine.medical_treatment ,Abnormal positions ,Tracheostomy tubes ,Swan Ganz Catheter ,Surgery ,Chest tube ,Medicine ,Dobhoff Tube ,business ,Central venous catheter ,Endotracheal tube - Abstract
This chapter describes the routine appearance and abnormal positions of a variety of monitoring and support devices, including endotracheal and tracheostomy tubes, nasogastric and Dobhoff tubes, PICC lines, and other vascular catheters, chest tubes, and pacer/ICD wires.
- Published
- 2019
- Full Text
- View/download PDF
43. 5230Association of cardiac output during targeted temperature management with mortality after out-of-hospital cardiac arrest
- Author
-
Jesper Kjaergaard, M. Wanscher, John Bro-Jeppesen, Christian Hassager, and Johannes Grand
- Subjects
Cardiac output ,medicine.medical_specialty ,Univariate analysis ,business.industry ,medicine.medical_treatment ,Cardiac index ,Hemodynamics ,Targeted temperature management ,Swan Ganz Catheter ,Cardiac Care Facilities ,Internal medicine ,Heart rate ,Cardiology ,Medicine ,Cardiology and Cardiovascular Medicine ,business - Abstract
Purpose Myocardial dysfunction and low cardiac output are common after out-of-hospital cardiac arrest (OHCA) as part of the post-cardiac arrest syndrome. This study investigates the association of cardiac output during targeted temperature management (TTM) with mortality. We hypothesized that low cardiac output during TTM is associated with mortality. Methods In the TTM-trial, which randomly allocated patients to TTM of 33°C or 36°C for 24 hours, we prospectively and consecutively monitored 171 patients with protocolized measurements from pulmonary artery catheters (PAC). Clinical and hemodynamic variables were registered at pre-specified time points in addition to 30-day survival status. Lactate, heart rate and cardiac index were measured at 3 time-points during TTM and averaged. We defined low cardiac output as a cardiac index during TTM Results Of 152 patients with available hemodynamic measurements, 71 (47%) had low cardiac output during TTM (TTM33: 38 (49%), TTM36: 33 (44%)). Low cardiac output was not associated with mortality in univariate analysis (hazard ratio (HR): 1.47 [0.83–2.59], p=0.19) or multivariate analysis adjusted for potential confounders (HRadjusted: 0.74 [0.38–1.44], p=0.37). Low cardiac output combined with HR>65 was associated with increased mortality (HR: 2.69 [1.51–4.79], p=0.0007) in univariate, but not in multivariate analysis (p=0.22) (Figure). Low cardiac output and HR2mmol/L was associated with increased mortality (HR: 2.73 [1.49–4.99], p=0.001) in univariate, but not in multivariate analysis (p=0.53), whereas patients with low cardiac output and lactate Figure 1 Conclusion This study found, that a frequent symptom during TTM is low cardiac output, which was not associated with mortality. However, patients with low cardiac output combined with either increased lactate or heart rate seems to be a population at risk. Whether low cardiac output should be corrected by inotropes or mechanical support to reduce mortality remains to be studied in prospective trials, but the efficacy of goal-directed therapy to increase cardiac output during TTM may be modest, especially if lactate and heart rate are normal. Acknowledgement/Funding The research fund Gangstedfonden and the Research fund of Rigshospitalet has supported this study with unrestricted salary in Dr. Grand's PhD project.
- Published
- 2019
- Full Text
- View/download PDF
44. P4512Impact of pulmonary artery catheter on all-cause death of patients with acute heart failure with preserved ejection fraction: Short-term results from the PURSUIT-HFpEF registry
- Author
-
Yasuharu Takeda, Yohei Sotomi, Atsushi Hirayama, Shungo Hikoso, Daisaku Nakatani, N Matsusaki, Shunsuke Tamaki, T Yamada, T Kobayashi, Masaaki Uematsu, Haruhiko Abe, Yoshio Yasumura, Yasuhiko Sakata, Yoshiharu Higuchi, and T Hayashi
- Subjects
medicine.medical_specialty ,Ejection fraction ,business.industry ,Internal medicine ,medicine.medical_treatment ,Cardiology ,medicine ,Pulmonary artery catheter ,Cardiology and Cardiovascular Medicine ,business ,Heart failure with preserved ejection fraction ,Swan Ganz Catheter ,All cause mortality - Abstract
Background Appropriate pulmonary artery catheter (PAC) use may effectively decrease mortality in acute heart failure patients. The concept that the pulmonary artery catheter (PAC) is a valuable tool for hemodynamic monitoring when used in appropriately selected patients and by physicians trained well to interpret and apply the data correctly provided has not been evaluated adequately yet in acute heart failure patients with preserved ejection fraction (HFpEF). Methods The PERSUIT-HFpEF Registry is a prospective, observational, multicenter cohort study on prognosis of HFpEF in Japan. Patients hospitalized for heart failure (diagnosed by using Framingham criteria) who met both of the following criteria were enrolled: 1) a left ventricular ejection fraction of 50% or more as measured at the local site by echocardiography; 2) an elevated level of N terminal pro brain natriuretic peptide (NT proBNP) (400 pg per milliliter or more) or brain natriuretic peptide (BNP) (100 pg per milliliter or more). In the present study, we evaluated the impact of PAC on all-cause death of the patients with HFpEF. PAC use was left at the discretion of attending physicians. Results The PERSUIT-HFpEF Registry enrolled 486 patients (81±9 years, 259 females, mean follow-up duration 198±195 days). Of these, data of PAC usage was available in 434 patients. Patients were further stratified according to use of a PAC: PAC 153 patients vs. non-PAC 281 patients. Length of hospitalization was numerically shorter in the PAC group than in the non-PAC group [20.3±14.7 vs. 22.5±17.4 days, p=0.182]. Kaplan-Meier estimated 1-year all-cause death rate was significantly lower in the PAC group than in the non-PAC group (9.5% vs. 19.1%, p=0.019). PAC use was associated with significant risk reduction of all-cause death [hazard ratio (HR) 0.425, 95% confidence interval (CI), 0.203–0.890, p=0.023] in the crude analysis. The significant risk reduction still existed after multivariate adjustment including potential confounders [HR 0.427, 95% CI, 0.185–0.984, p=0.046] Kaplan Meier analysis Conclusions In the real-world Asian registry data, PAC use was associated with the improved all-cause death rate, suggesting that the PAC might be a useful guidance tool for treatment of the patients with HFpEF. Acknowledgement/Funding Roche diagnostics FUJIFILM Toyama Chemical
- Published
- 2019
- Full Text
- View/download PDF
45. P2473Non-invasive assessment of central venous pressure in heart failure: comparing three-dimensional echocardiography and Swan-Ganz catheter
- Author
-
Jan Gummert, Henrik Fox, A. Costard-Jaeckle, Lech Paluszkiewicz, Volker Rudolph, and T Szymczyk
- Subjects
medicine.medical_specialty ,business.industry ,Internal medicine ,Heart failure ,Central venous pressure ,Cardiology ,Medicine ,Three dimensional echocardiography ,Cardiology and Cardiovascular Medicine ,business ,medicine.disease ,Swan Ganz Catheter - Abstract
Background Assessing hemodynamics, in particular central venous pressure (CVP) is essential in heart failure diagnostics, leading individual therapy. Hereby, invasive measurement through Swan-Ganz right heart catheterization (RHC) is considered gold standard for patient evaluation, but catheterization implies risks of invasiveness including bleeding, infection, vessel and nerve injury, as well as patient discomfort. Non-invasive methods are warranted, but no alternative technique is validated yet. Two-dimensional echocardiography (2DE) is believed to be uncertain in this approach as vena cava often shows ellipse-shapes. Therefore, this study sought to investigate standardized and breathing corrected three-dimensional inferior vena cava echocardiography (3DE) to directly compare CVP with right heart catheterization. Methods and results We prospectively included 100 consecutive heart failure patients in this study (mean age 53±12 years, body mass index 27±5, New York Heart Association functional class 2.3±0.6, left ventricular ejection fraction 34.1±12.8%, brain natriuretic peptide 658.13±974.03, 76% male), all underwent Swan-Ganz right-heart catheterization and immediately both 2DE and 3DE (Philips EPIQ 7G) of inferior vena cava. From two-dimensional data the diameter of IVC was measured perpendicularly in long and short-axis. From 3DE data a cross-sectional image of IVC was reconstructed for both vertical and horizontal diameters of IVC as well as the area of IVC. Established 2DE images revealed mean vena cava sizes of 15.9±5.9 mm, while standardized cross-sectional breathing corrected 3DE images showed diameters of 19.8±7.8 mm in longitudinal axis and 15.74±7.8 in short axis. RHC mean CVP was 9.00±5.4 mmHg and correlation of CVP and 2DE measurements failed adequate correlation (2DE 95% CI 0.19–1.61; r=0.25; p=0.312). However, 3DE axis ratio assessment correlated well with invasive CVP and showed reproducible results (3DE 95% CI 0.26–0.69; r=0.89; p Conclusions Standardized 3DE correlates well with invasive CVP while established 2DE usual care assessment does not show reliable CVP correlation. 3DE CVP assessment may represent a more feasible and easily applicable method for CVP measurement, including absence for risks of right heart catheterization. Further studies are ongoing to validate these findings in the future.
- Published
- 2019
- Full Text
- View/download PDF
46. Chest radiographs of cardiac devices (Part 1): Lines, tubes, non-cardiac medical devices and materials
- Author
-
Gavin Low, Timothy Alexander, Vimal Patel, and Rishi Philip Mathew
- Subjects
lcsh:Medical physics. Medical radiology. Nuclear medicine ,Chest radiographs ,medicine.medical_specialty ,lcsh:R895-920 ,Radiography ,medicine.medical_treatment ,central venous catheter ,Review Article ,Swan Ganz catheter ,tracheostomy tube ,endotracheal tube ,intercostal drainage tube ,Intensive care ,Medicine ,Radiology, Nuclear Medicine and imaging ,Tracheostomy tube ,Endotracheal tube ,Radiological and Ultrasound Technology ,Critically ill ,business.industry ,Radiology ,Erratum ,nasogastric tube ,business ,Central venous catheter - Abstract
Chest radiographs (CXRs) are the most common imaging investigations undertaken because of their value in evaluating the cardiorespiratory system. They play a vital role in intensive care units for evaluating the critically ill. It is therefore very common for the radiologist to encounter tubes, lines, medical devices and materials on a daily basis. It is important for the interpreting radiologist not only to identify these iatrogenic objects, but also to look for their accurate placement as well as for any complications related to their placement, which may be seen either on the immediate post-procedural CXR or on a follow-up CXR. In this article, we discussed and illustrated the routinely encountered tubes and lines that one may see on a CXR as well as some of their complications. In addition, we also provide a brief overview of other important non-cardiac medical devices and materials that may be seen on CXRs.
- Published
- 2019
- Full Text
- View/download PDF
47. Literature and new innovations leading to the rise and fall of the Swan-Ganz catheter
- Author
-
Sukumar P. Desai, John Fox, and Yun-Yun K. Chen
- Subjects
medicine.medical_specialty ,Technology ,medicine.medical_treatment ,Pulmonary Artery ,History, 21st Century ,Swan Ganz Catheter ,law.invention ,03 medical and health sciences ,0302 clinical medicine ,History and Philosophy of Science ,Randomized controlled trial ,030202 anesthesiology ,law ,medicine ,Humans ,Risks and benefits ,Intensive care medicine ,Randomized Controlled Trials as Topic ,business.industry ,Critically ill ,Pulmonary artery catheter ,food and beverages ,History, 20th Century ,humanities ,Catheter ,Observational Studies as Topic ,Anesthesiology and Pain Medicine ,Blood pressure ,Catheterization, Swan-Ganz ,Observational study ,business ,030217 neurology & neurosurgery ,Vascular Access Devices - Abstract
Background In 1970, Harold James Charles Swan and William Ganz published their work on the pulmonary artery catheter (PAC or Swan-Ganz catheter). They described the successful bedside use of a flow-directed catheter to continuously evaluate the heart, and it was used extensively in the years following to care for critically ill patients. In recent decades, clinicians have reevaluated the risks and benefits of the PAC. Aim We acknowledge the contributions of Swan and Ganz and discuss literature, including randomized controlled trials, and new technology surrounding the rise and fall in use of the PAC. Methods We performed a literature search of retrospective and prospective studies, including randomized controlled trials, and editorials to understand the history and clinical outcomes of the PAC. Results In the 1980s, clinicians began to question the benefits of the PAC. In 1996 and 2003, a large observational study and randomized controlled trial, respectively, showed no clear benefits in outcome. Thereafter, use of PACs began to drop precipitously. New less and noninvasive technology can estimate cardiac output and blood pressure continuously. Conclusions Swan and Ganz contributed to the bedside understanding of the pathophysiology of the heart. The history of the rise and fall in use of the PAC parallels the literature and invention of less-invasive technology. Although the PAC has not been shown to improve clinical outcomes in large randomized controlled trials, it may still be useful in select patients. New less-invasive and noninvasive technology may ultimately replace it if literature supports it.
- Published
- 2019
48. Angioplasty inflated balloon to unknot an entrapped Swan-Ganz catheter
- Author
-
Paul Ohayon, Didier Carrié, Nicolas Boudou, and Anthony Matta
- Subjects
medicine.medical_specialty ,business.industry ,Images in Cardiology ,Angioplasty ,medicine.medical_treatment ,medicine ,Cardiology and Cardiovascular Medicine ,Unknot ,business ,Balloon ,Swan Ganz Catheter ,Surgery ,Balloon dilatation - Published
- 2019
49. Cardiac output measured by transthoracic echocardiography and Swan-Ganz catheter. A comparative study in mechanically ventilated patients with high positive end-expiratory pressure
- Author
-
Arturo Pazos, José Gorrasi, Ricardo Lluberas, Lucía Florio, Carlos Américo, Gabriel Parma, and Natalia Lluberas
- Subjects
Cardiac output ,Pulmonary artery catheter ,030204 cardiovascular system & hematology ,Critical Care and Intensive Care Medicine ,Swan Ganz Catheter ,Positive-Pressure Respiration ,03 medical and health sciences ,0302 clinical medicine ,030202 anesthesiology ,Hemodynamic monitoring ,Medicine ,Humans ,Positive end-expiratory pressure ,Aged ,business.industry ,General Medicine ,Original Articles ,Middle Aged ,Respiration, Artificial ,Echocardiography ,Catheterization, Swan-Ganz ,cardiovascular system ,business ,Nuclear medicine - Abstract
To compare cardiac output measurements by transthoracic echocardiography and a pulmonary artery catheter in mechanically ventilated patients with high positive end-expiratory pressure. To evaluate the effect of tricuspid regurgitation.Sixteen mechanically ventilated patients were studied. Cardiac output was measured by pulmonary artery catheterization and transthoracic echocardiography. Measurements were performed at different levels of positive end-expiratory pressure (10cmH2O, 15cmH2O, and 20cmH2O). The effect of tricuspid regurgitation on cardiac output measurement was evaluated. The intraclass correlation coefficient was studied; the mean error and limits of agreement were studied with the Bland-Altman plot. The error rate was calculated.Forty-four pairs of cardiac output measurements were obtained. An intraclass correlation coefficient of 0.908 was found (p0.001). The mean error was 0.44L/min for cardiac output values between 5 and 13L/min. The limits of agreement were 3.25L/min and -2.37L/min. With tricuspid insufficiency, the intraclass correlation coefficient was 0.791, and without tricuspid insufficiency, 0.935. Tricuspid insufficiency increased the error rate from 32% to 52%.In patients with high positive end-expiratory pressure, cardiac output measurement by transthoracic echocardiography is comparable to that with a pulmonary artery catheter. Tricuspid regurgitation influences the intraclass correlation coefficient. In patients with high positive end-expiratory pressure, the use of transthoracic echocardiography to measure cardiac output is comparable to invasive measures.Comparar las medidas de gasto cardiaco por ecocardiografía transtorácica y por catéter arterial pulmonar en pacientes en ventilación mecánica con presión positiva al final de la espiración elevada. Evaluar el efecto de la insuficiencia tricúspide.Se estudiaron 16 pacientes en ventilación mecánica. El gasto cardiaco se midió con el catéter arterial pulmonar y por ecocardiografía transtorácica. Las medidas se realizaron en diferentes niveles de presión positiva al final de la espiración (10cmH2O, 15cmH2O, y 20cmH2O). Se evalúo el efecto de la insuficiencia tricúspide sobre la medida de gasto cardiaco. Se estudió el coeficiente de correlación intraclase; el error medio y los límites de concordancia se estudiaron con el diagrama de Bland-Altman. Se calculó el porcentaje de error.Se obtuvieron 44 pares de medidas de gasto cardiaco. Se obtuvo un coeficiente de correlación intraclase de 0,908, p0,001; el error medio fue 0,44L/min para valores de gasto cardíaco entre 5 a 13L/min. Los límites de concordancia se encontraron entre 3,25L/min y -2,37L/min. Con insuficiencia tricúspide el coeficiente de correlación intraclase fue 0,791, sin insuficiencia tricúspide el coeficiente de correlación intraclase fue 0,935. La presencia de insuficiencia tricúspide aumentó el porcentaje de error de 32 % a 52%.En pacientes con presión positiva al final de la espiración elevada la medida de gasto cardiaco por ecocardiografía transtorácica es comparable con catéter arterial pulmonar. La presencia de insuficiencia tricúspide influye en el coeficiente de correlación intraclase. En pacientes con presión positiva al final de la espiración elevada, el uso de ecocardiografía transtorácica para medir gasto cardiaco es comparable con las medidas invasivas.
- Published
- 2019
50. Harvest of Endothelial Cells from the Balloon Tips of Swan-Ganz Catheters after Right Heart Catheterization
- Author
-
Phillip H Gallo, Reina Perez, Raymond L. Benza, Michael J. Passineau, and Gretchen Williams
- Subjects
Right heart catheterization ,medicine.medical_specialty ,Cardiac Catheterization ,Endothelium ,General Chemical Engineering ,Hypertension, Pulmonary ,Cell Separation ,Pulmonary Artery ,Balloon ,General Biochemistry, Genetics and Molecular Biology ,Swan Ganz Catheter ,Internal medicine ,medicine.artery ,medicine ,Humans ,General Immunology and Microbiology ,business.industry ,General Neuroscience ,Endothelial Cells ,medicine.disease ,Pulmonary hypertension ,Catheter ,medicine.anatomical_structure ,Heart failure ,Catheterization, Swan-Ganz ,Pulmonary artery ,Cardiology ,business - Abstract
A variety of pathologies lead to pulmonary hypertension (PH), which is defined as a mean pulmonary artery pressure exceeding 25 mmHg at rest. To further diagnose and manage PH, patients undergo repeated right heart catheterizations (RHC) wherein a Swan-Ganz catheter is advanced into a branch of the pulmonary artery and a balloon is inflated to wedge the catheter tip. This article illustrates a protocol whereby pulmonary artery endothelial cells (PAECs) may be harvested from the balloon tips of Swan-Ganz catheters after RHC, and purified with an anti- CD146 affinity column technique to purify putative PAECs. These cells might be used to provide an in situ snapshot of the biological state of the pulmonary vasculature endothelium to complement hemodynamic measurements obtained during RHC. Harvested and purified PAECs may be used for either cell culture or for subsequent analytical assays such as flow cytometery.
- Published
- 2019