310 results on '"Técnicas de diagnóstico oftalmológico"'
Search Results
2. Tear film osmolarity variation between weeks in healthy and dry eye disease subjects.
- Author
-
Pena-Verdeal, Hugo, Garcia-Queiruga, Jacobo, Sabucedo-Villamarin, Belen, Giraldez, María J., and Yebra-Pimentel, Eva
- Subjects
DRY eye syndromes ,OSMOLAR concentration ,PEARSON correlation (Statistics) ,VOLUNTEER recruitment ,DIAGNOSIS methods - Abstract
Copyright of Arquivos Brasileiros de Oftalmologia is the property of Arquivos Brasileiros de Oftalmologia and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
- Published
- 2024
- Full Text
- View/download PDF
3. Translation and validation of the 5-Item Dry Eye Questionnaire into Portuguese.
- Author
-
Grave Gross, Luísa, Pozzebon, Maria Eugênia, Pinheiro Favarato, Arthur, Ayub, Gabriel, and Alves, Mônica
- Subjects
TRANSLATING & interpreting ,DRY eye syndromes ,EYE diseases ,PEARSON correlation (Statistics) ,INTER-observer reliability ,MEDICAL screening - Abstract
Copyright of Arquivos Brasileiros de Oftalmologia is the property of Arquivos Brasileiros de Oftalmologia and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
- Published
- 2024
- Full Text
- View/download PDF
4. Agreement between corneal diameter measurements obtained with an optical biometer and a Placido-based topographer.
- Author
-
Teixeira, Eloisa Gomes Rosario M., Fiuza Gomes, Beatriz, Santana, João Dominice, Santhiago, Marcony R., Alencar Costa, Adroaldo, and Moraes Jr, Haroldo V.
- Subjects
OPTICAL measurements ,PEARSON correlation (Statistics) ,CORNEA ,OPERATIVE surgery ,CORNEAL topography ,STATISTICAL correlation ,DECISION making - Abstract
Copyright of Arquivos Brasileiros de Oftalmologia is the property of Arquivos Brasileiros de Oftalmologia and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
- Published
- 2023
- Full Text
- View/download PDF
5. Evaluation of childhood cataract characteristics at a tertiary referral center.
- Author
-
Silverio Rodrigues, Ana Paula, Nakanami, Célia Regina, Rolim de Moura Souza, Christiane Regina, Bueno Moraes, Nilva Simerem, Araújo Zin, Andréa, and de Freitas, Denise
- Subjects
LOW vision ,CATARACT ,CATARACT surgery ,DELAYED diagnosis ,TERTIARY care ,PEDIATRIC ophthalmology ,PHACOEMULSIFICATION ,TREATMENT delay (Medicine) ,STRABISMUS - Abstract
Copyright of Arquivos Brasileiros de Oftalmologia is the property of Arquivos Brasileiros de Oftalmologia and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
- Published
- 2023
- Full Text
- View/download PDF
6. Ocular surface assessment and morphological alterations in meibomian glands with non-contact meibography in electronic cigarette smokers.
- Author
-
Kalayci, Mustafa, Cetinkaya, Ersan, Yaprak, Lütfiye, Yigit, Kenan, Suren, Elcin, Dogan, Berna, and Erol, Muhammet Kazim
- Subjects
MEIBOMIAN glands ,ELECTRONIC cigarettes ,CIGARETTE smokers ,SMOKING ,EYELIDS - Abstract
Copyright of Arquivos Brasileiros de Oftalmologia is the property of Arquivos Brasileiros de Oftalmologia and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
- Published
- 2023
- Full Text
- View/download PDF
7. Brazilian guideline for pediatric cycloplegia and mydriasis.
- Author
-
Curi, Ian, Akiko Nakayama, Simone, Mota Pereira, Érika, Moreira Hopker, Luisa, Ejzenbaum, Fábio, Boaventura Barcellos, Ronaldo, da Cruz Ferreira, Rosane, Fialho Cronemberger, Monica, Mckeown, Craig A., and Dutra Rossetto, Júlia
- Subjects
MYDRIASIS ,VISUAL accommodation ,PEDIATRIC ophthalmology ,RETROLENTAL fibroplasia ,NEWBORN infants ,LITERATURE reviews - Abstract
Copyright of Arquivos Brasileiros de Oftalmologia is the property of Arquivos Brasileiros de Oftalmologia and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
- Published
- 2023
- Full Text
- View/download PDF
8. Characterization of meibomian gland dysfunction in patients with rosacea.
- Author
-
Buzolin Barbosa, Eduardo, Melo Tavares, Carla, Luz da Silva, Dimitri Felipe, Souza Santos, Lorraine, Eloy da Costa França, Andrea Fernandes, and Alves, Monica
- Subjects
MEIBOMIAN glands ,ROSACEA ,DRY eye syndromes ,VISUAL acuity ,TEST scoring - Abstract
Copyright of Arquivos Brasileiros de Oftalmologia is the property of Arquivos Brasileiros de Oftalmologia and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
- Published
- 2023
- Full Text
- View/download PDF
9. Evaluación del manejo y seguimiento de los pacientes diabéticos en la prevención de la retinopatía diabética
- Author
-
García, Purificación Piñas, Ruiz Romero, María Victoria, Luque Romero, Luis Gabriel, Gómez Jiménez, Carlos Alberto, Castillón Torre, L., Hernández Martínez, Francisco Javier, García, Purificación Piñas, Ruiz Romero, María Victoria, Luque Romero, Luis Gabriel, Gómez Jiménez, Carlos Alberto, Castillón Torre, L., and Hernández Martínez, Francisco Javier
- Abstract
FUNDAMENTOS // La diabetes mellitus es una enfermedad crónica con alta morbimortalidad que afecta a 537 millones de adultos en el mundo. España es el segundo país europeo en prevalencia, con un 14,8% en población de veinte-setenta y nueve años, con 11,6 casos por cada 1.000 personas/año. La retinopatía diabética (RD) es la quinta causa de pérdida de visión a nivel mundial y la séptima causa de ceguera/discapacidad visual entre afiliados a la Organización Nacional de Ciegos de España (ONCE). La detección precoz de RD previene la ceguera en diabéticos y está condicionada por la hemoglobina glicosilada. El objetivo de este trabajo fue analizar el manejo de los pacientes diabéticos en la comarca del Aljarafe (Sevilla) e identificar oportunidades de mejora en la coordinación de su seguimiento entre el médico de Atención Primaria y el médico oftalmólogo. MÉTODOS // Se realizó un estudio observacional retrospectivo (2016-2019) con los pacientes registrados en el censo de diabéticos de los veintiocho municipios del Aljarafe. Se consultó la historia de salud de Atención Primaria y Hospital, así como el programa de Telemedicina. En cuanto al análisis estadístico, para variables cualitativas se calcularon totales y porcentajes; para variables cuantitativas, media y distribución estándar (si distribución normal), y la mediana y cuartiles (distribución no normal). RESULTADOS // Se registraron 17.175 diabéticos en el Aljarafe (5,7% de población); 14.440 pacientes (84,1%) tenían alguna determinación de hemoglobina durante el periodo, 9.228 (63,9%) las tenían todas en rango adecuado. Tenían control fundoscópico 12.040 diabéticos (70,1%), y de los que no, 346 (10,6%) tenían todas fuera de rango. Hubo 1.878 (10,9%) pacientes sin control fundoscópico ni metabólico, 1.019 (54,3%) eran mujeres, 1.219 (64,9%) menores de sesenta y cinco años, 1.019 (54,3%) con comorbilidad grave. CONCLUSIONES // La mayoría de los pacientes presentan un cribado adecuado y, más de la mitad, determinaciones
- Published
- 2024
10. Tear film osmolarity variation between weeks in healthy and dry eye disease subjects
- Author
-
Universidade de Santiago de Compostela. Departamento de Física Aplicada, Pena Verdeal, Hugo, García Queiruga, Jacobo, Sabucedo Villamarín, Belén, Giráldez Fernández, María Jesús, Yebra-Pimentel Vilar, Eva, Universidade de Santiago de Compostela. Departamento de Física Aplicada, Pena Verdeal, Hugo, García Queiruga, Jacobo, Sabucedo Villamarín, Belén, Giráldez Fernández, María Jesús, and Yebra-Pimentel Vilar, Eva
- Abstract
Purpose: The possible variability in diagnostic test results is a statistical feature of dry eye disease patients. The clinician should consider tear film variations over time since the timing of tear film measurements is important for proper diagnosis. The purpose of the present study was to analyze the inter-week variation of osmolarity measurement in healthy and dry eye disease participants. Methods: Based on the Dry Eye Workshop II (DEWS-II) diagnostic methodology report criteria, a battery of tests (Ocular Surface Disease Index [OSDI] questionnaire, breakup time, and corneal staining) was administered to rule out the presence of dry eye disease. A total of 40 qualified volunteers were recruited into two groups: with only 20 healthy and 20 dry eye disease participants. The inter-week variation of osmolarity in the two groups was measured using a TearLab osmometer in two sessions one-week apart. The differences between the results were calculated. Results: There were no significant differences in osmolarity between the two sessions for either the healthy (paired t-test; p=0.085) or dry eye disease (paired t-test; p=0.093) participants. Moreover, there was no significant correlation between the means and differences in either session on healthy (Pearson correlation: r=0.020; p=0.935) or dry eye disease (Pearson correlation: r=-0.022; p=0.928) participants. In session 1, there was a significant difference in osmolarity values between groups (unpaired t-test; p=0.001), but no difference was found in session 2 (unpaired t-test; p=0.292). Conclusions: The present study discovered no inter-week variation in the tear film osmolarity of healthy and dry eye disease participants classified based on the DEWS-II criteria., Objetivo: A possível variabilidade nos resultados de testes diagnósticos é uma característica estatística dos pacientes com síndrome do olho seco. O médico deve considerar as variações do filme lacrimal ao longo do tempo, pois o momento em que o filme lacrimal é medido pode ser crítico para o diagnóstico adequado. O objetivo deste estudo foi analisar a variação semanal da osmolaridade do filme lacrimal em participantes saudáveis e em outros com síndrome do olho seco. Métodos: Com base nos critérios da metodologia de diagnóstico do relatório da Dry Eye Workshop II (DEWSII), foi aplicada uma bateria de testes (questionário do índice de doença da superfície ocular [OSDI], tempo de ruptura do filme lacrimal e coloração da córnea) para descartar a presença de síndrome do olho seco. Um total de 40 voluntários qualificados foi recrutado e distribuído em dois grupos de 20 participantes saudáveis e 20 participantes com síndrome do olho seco. A variação da osmolaridade entre semanas foi medida com um osmômetro TearLab em duas sessões com uma semana de intervalo nos dois grupos. As diferenças entre os resultados foram então calculadas. Resultados: Não foram encontradas diferenças significativas na osmolaridade entre as medidas obtidas nas duas sessões, nem no grupo de participantes saudáveis (teste de t pareado; p=0,085), nem no de participantes com síndrome do olho seco (teste de t pareado; p=0,093). Não foi detectada nenhuma correlação significativa entre as médias e diferenças entre as duas sessões entre participantes saudáveis (correlação de Pearson: r=0,020, p=0,935) e aqueles com síndrome do olho seco (correlação Pearson: r=-0,022, p=0,928). Foi encontrada uma diferença significativa nos valores de osmolaridade entre os dois grupos na primeira sessão (teste de t não pareado; p=0,001), mas nenhuma diferença foi encontrada na segunda sessão (teste de t não pareado; p=0,292). Conclusões: O presente estudo não encontrou variação entre semanas consecutivas na osmolaridade do
- Published
- 2024
11. Avaliação do paciente com diminuição da acuidade visual
- Author
-
Italo Pena de Oliveira and João Marcello Furtado
- Subjects
Oftalmologia ,Acuidade Visual ,exame ocular ,Técnicas de Diagnóstico Oftalmológico ,Medicine - Abstract
A queixa de diminuição da acuidade visual é muito frequente nos diversos cenários de atendimento médico. É importante, portanto, que o médico generalista esteja apto a realizar uma avaliação qualificada na apresentação inicial do paciente, de modo a identificar doenças prontamente tratáveis e diferenciá-las daquelas que devem ser encaminhadas ao especialista. Este artigo aborda, em detalhes, a avaliação do paciente com queixa de baixa acuidade visual.
- Published
- 2022
12. Manifestaciones clínicas y evolución a largo plazo de tres casos de rosácea ocular atendidos en un hospital de alta especialidad del sureste de México
- Author
-
Fiona Xacur-García, Rodrigo Díaz-Novelo, Linnete Herrera-David, Paulina Moreno-Arjona, and Nina Méndez-Domínguez
- Subjects
rosácea ,oftalmopatías ,técnicas de diagnóstico oftalmológico ,pronóstico ,trasplante ,Medicine ,Arctic medicine. Tropical medicine ,RC955-962 - Abstract
La rosácea es una alteración cutánea crónica que se ha asociado con factores etiológicos inespecíficos y diversas manifestaciones sistémicas. La rosácea cutánea suele evolucionar a rosácea ocular del 6 al 72 % de los pacientes. Al no existir criterios específicos que la caractericen, la rosácea ocular implica un reto diagnóstico. Para fortalecer la sospecha diagnóstica temprana, se presentan tres casos de pacientes con evolución clínica distinta, pero que tuvieron en común el retraso diagnóstico, lo que se tradujo en manifestaciones graves y daño ocular extenso.
- Published
- 2020
- Full Text
- View/download PDF
13. Análise do ensino da oftalmoscopia direta nos cursos de graduação em Medicina do Estado de Mato Grosso
- Author
-
Alisson Vitor Esidio and Carolina Ramos Mosena de Angeloni
- Subjects
Ensino ,Aprendizagem ,Oftalmoscopia ,Técnicas de diagnóstico oftalmológico ,Estudantes de Medicina ,Ophthalmology ,RE1-994 - Abstract
Resumo Objetivo: o ensino da oftalmoscopia direta vem recebendo menos atenção na graduação, o que resulta em médicos sem confiança para realizá-la. Diante disso, foi analisada a autopercepção dos acadêmicos dos cursos de medicina de Mato Grosso sobre a oftalmoscopia direta e os principais fatores responsáveis pela insegurança em executá-la. Métodos: foi realizada a revisão bibliográfica nas bases Pubmed, Scielo e Biblioteca Virtual em Saúde, sendo construído um questionário aplicado, pelo método bola de neve e após parecer favorável do Comitê de Ética, a acadêmicos de medicina do Mato Grosso que estavam cursando regularmente o quinto ou sexto ano do curso. A análise estatística foi realizada no software SPSS 20, considerando intervalo de confiança de 95%. Resultados: verificou-se que a proporção de acadêmicos que tiveram aulas sobre a oftalmoscopia direta foi superior em universidades públicas (p < 0,001); que a maioria dos alunos não acredita que suas escolas forneçam as condições adequadas para o aprendizado do exame (p = 0,001); que 10,5% se consideram conhecedores da teoria e prática da oftalmoscopia direta (p = 0,004); que a falta de treinamento durante a graduação é o principal fator que dificulta o aprendizado do exame; e que isso resulta em falta de confiança em realizar o mesmo. Conclusão: a oftalmoscopia direta não tem recebido a devida importância durante a graduação em medicina no estado de Mato Grosso. Com tais resultados, pode-se tomar medidas que melhorem o ensino-aprendizado da técnica, o que posteriormente trará benefício para a população.
- Published
- 2020
- Full Text
- View/download PDF
14. Brazilian guidelines on the frequency of ophthalmic assessment and recommended examinations in healthy children younger than 5 years.
- Author
-
Dutra Rossetto, Julia, Hopker, Luisa Moreira, Rebouças de Carvalho, Luis Eduardo M., Gaal Vadas, Marcelo, Araújo Zin, Andrea, Scalamandré Mendonça, Tomás, Solé, Dirceu, Silva, Luciana R., Rolim-de-Moura, Christiane, Ferreira Sá, Luis Carlos, and Ejzenbaum, Fabio
- Subjects
VISION ,PHYSICIANS ,VISION disorders ,PEDIATRICIANS ,PEDIATRIC ophthalmology ,EYE movements - Abstract
Copyright of Arquivos Brasileiros de Oftalmologia is the property of Arquivos Brasileiros de Oftalmologia and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
- Published
- 2021
- Full Text
- View/download PDF
15. Diferenças de mensuração de acuidade visual e velocidade de leitura para perto entre pacientes com retinopatia diabética. Repercussão entre conceitos de deficiência visual parcial e cegueira legal
- Author
-
Roberta Freitas Momenté, Isabella Couto Amaral, Luiz Guilherme Coimbra de Brito, João Gabriel Volpato Ferraresi, Maria Luisa Gois da Fonsêca, Nadyr Antônia Damasceno, Luiz Claudio Santos de Souza Lima, Mauricio Bastos Pereira, and Eduardo de França Damasceno
- Subjects
Acuidade visual ,Cegueira legal ,Leitura ,Técnicas de diagnóstico oftalmológico ,Ophthalmology ,RE1-994 - Abstract
RESUMO Objetivo: Comparar a acurácia entre a acuidade visual com melhor correção óptica em pacientes com retinopatia diabética e acuidade visual com correção óptica menor ou igual a 20/200 em ambos os olhos mensurada pela tabela de Snellen e pela tabela ETDRS, além da avaliação do tempo de leitura com tabela de leitura de Jaeger. Métodos: Estudo observacional e transversal. ormação de Grupos de Pesquisa: o Grupo I foi formado por pacientes com acuidade visual de 20/200 e o Grupo II, por pacientes com acuidade visual maior de 20/200. Os pacientes de ambos os grupos foram subdivididos em aqueles com retinopatia diabética não proliferativa e os com retinopatia diabética proliferativa. As variáveis pesquisadas foram sexo, idade, tabela ETDRS nos subgrupos (igual a 20/200, igual a 20/400 e maior de 20/200 e 20/400) e tempo de leitura da tabela de Jaeger para perto. O índice de significância estatística deste estudo foi de 5%. Resultados: Participaram do estudo 62 pacientes diabéticos, sendo 33 com retinopatia diabética não proliferativa e 29 com retinopatia diabética proliferativa. Dentre os pacientes com retinopatia diabética não proliferativa, 19 tinham acuidade visual com melhor correção óptica de 20/200 (30,6% da amostra), e 13 pacientes eram portadores de retinopatia diabética proliferativa com acuidade visual com melhor correção óptica de 20/200 (20,9% da amostra). A correlação entre a tabela Snellen e a tabela ETDRS revelou que 16 pacientes (25,8% da amostra) com cegueira legal apresentaram acuidade visual entre 20/180 e 20/120 segundo a tabela ETDRS. Para os pacientes portadores de retinopatia diabética não proliferativa com acuidade visual de 20/200 pela tabela ETDRS, houve tempo médio de leitura para perto da tabela de Jaeger de 23,6±1,4 segundos. Na análise estatística da acuidade visual mensurada com a Tabela de Snellen em comparação com a Tabela de Leitura para perto (Jaeger), mensurando tempo de leitura, ahouve significância estatística (p=0,04). Conclusão: Pacientes diabéticos com cegueira legal segundo a tabela de Snellen apresentam sua real capacidade visual residual subavaliada. É importante levar em consideração o tempo de leitura e o uso da tabela ETDRS para melhor acurácia.
- Published
- 2021
- Full Text
- View/download PDF
16. Assessment of short-term intraocular pressure parameters in phakic and pseudophakic patients with primary open-angle glaucoma.
- Author
-
Lourenço, Adriana Sobral, Quirino de Araújo, Candice Cristina, Miguel dos Santos, Procópio, Prata, Tiago S., Vieira Lopes, Nara Lidia, Ribeiro dos Santos, Regina Cândido, Gracitelli, Carolina P. B., and Lima de Faria, Nubia Vanessa
- Subjects
INTRAOCULAR pressure ,OPEN-angle glaucoma - Abstract
Copyright of Arquivos Brasileiros de Oftalmologia is the property of Arquivos Brasileiros de Oftalmologia and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
- Published
- 2021
- Full Text
- View/download PDF
17. Use of automated quantitative pupillometric evaluation for monitoring the severity of diabetic retinopathy.
- Author
-
Cankurtaran, Veysel, Ilhan, Cagri, Tekin, Kemal, Citirik, Mehmet, Dirican, Emre, and Gurkan, Eren
- Subjects
DIABETIC retinopathy ,TYPE 2 diabetes ,DIABETES - Abstract
Copyright of Arquivos Brasileiros de Oftalmologia is the property of Arquivos Brasileiros de Oftalmologia and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
- Published
- 2021
- Full Text
- View/download PDF
18. Rastreamento visual, photoscreening e dispensação de óculos com a tecnologia ready to Clip™.
- Author
-
Rey de Faria, Marco Antônio, Oliveira Dantas, Daniel, Ruiz Alves, Milton, Ferreira de Medeiros, Bruno César, Florêncio Cabral, Ana Beatriz, Rocha Dantas, Breno Gustavo, Favero Demeda, Vanessa, Matos Neto, Carlos, Arrais de Azevedo, Luciana, Cavalcante de Souza, Alessandra, Ferreira Camilo, Leonardo, Lima Silva, Rodolfo, Gonçalves Fernandes, Lara, Isaías da Silva, Francisco, and Silva do Carmo, Luizy Millene
- Subjects
- *
SCHOOL children , *REFRACTIVE errors , *SCHOOL dropouts , *MEASUREMENT errors , *VISION disorders - Abstract
Background: The visual screening performed in schools is sometimes the only opportunity to detect uncorrected refraction errors (URE) causing low visual impairments, prejudice in the acquisition of knowledge, dropout and school repetition, poor motor skills, difficulty in social interaction and low self-esteem in schoolchildren. Objectives: To compare the detection of URE in elementary school children by visual screening (measurement of the AV with the Snellen table) and photoscreening; to evaluate the accuracy of the Spot™ Vision Screener (Welch Allyn) as an autorefractor by comparing its refraction measurements with those of the autorefractor Topcon KR 800 (Japan) and to verify the proportion of glasses with ready to Clip™ technology dispensed at the time of the students' evaluation. Methods: Two hundred ninety-seven students were submitted to visual screening (cutoff point: AVmonocular ≤ 0.7 and/or difference two Snellen lines between the eyes), photoscreening (cutoff point: hypermetropia ≥ 3, 00D, myopia ≥ 0, 75D and astigmatism > 1D) and the measurement of the refraction error under cycloplegia with the photoscreener and autorefractor. Only the refraction data of the right eye were analyzed. The findings were converted into vectors of magnitude for analysis. Results: The sensitivity and specificity values of the visual screening method were 67.2% and 63.5% and photo screening were 76.1% and 79.1%. The mean difference between refraction by SVS and autorefractor was of + 0.154 SD combined with -0.170 DC in the 6-degree axis for the right eye of each patient. Conclusions: In the population evaluated the method of refractive screening by photoscreener was more effective than the visual screening. The comparison of the results of refraction under cycloplegia with the autorefractor validated the use of photoscreener as an accurate refraction method for the measurement of refractive errors in schoolchildren. The majority of the students received their glasses with ready to Clip™ technology at the time of prescription. [ABSTRACT FROM AUTHOR]
- Published
- 2020
- Full Text
- View/download PDF
19. Manifestaciones clínicas y evolución a largo plazo en tres casos de rosácea ocular atendidos en un hospital de alta especialidad del sureste de México.
- Author
-
Xacur-García, Fiona, Díaz-Novelo, Rodrigo, Herrera-David, Linette, Moreno-Arjona, Paulina, and Méndez-Domínguez, Nina
- Abstract
Rosacea is a chronic skin disorder that has been associated with unspecific etiologic factors and diverse systemic manifestations. Cutaneous rosacea usually evolves to ocular rosacea in 6 to 72% of patients. In the absence of specific criteria that characterize this pathology, ocular rosacea can mean a diagnostic challenge. In order to offer elements to strengthen diagnostic suspicion early, we present three cases of patients with different clinical evolution, but who had in common the diagnostic delay that resulted in severe manifestations and extensive ocular damage. [ABSTRACT FROM AUTHOR]
- Published
- 2020
20. Manifestaciones clínicas y evolución a largo plazo de tres casos de rosácea ocular atendidos en un hospital de alta especialidad del sureste de México.
- Author
-
Xacur-García, Fiona, Díaz-Novelo, Rodrigo, Herrera-David, Linette, Moreno-Arjona, Paulina, and Méndez-Domínguez, Nina
- Subjects
EYE diseases ,ROSACEA ,PATHOLOGY ,SUSPICION ,SKIN ,DISEASES - Abstract
Copyright of Biomédica: Revista del Instituto Nacional de Salud is the property of Instituto Nacional de Salud of Colombia and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
- Published
- 2020
- Full Text
- View/download PDF
21. Mapping the corneal thickness and volume in patients with Down syndrome: a comparative population-based study.
- Author
-
Hashemi, Hassan, Makateb, Ali, Mehravaran, Shiva, Fotouhi, Akbar, Shariati, Fereshteh, and Asgari, Soheila
- Subjects
PEOPLE with Down syndrome ,PATIENTS' rights ,DOWN syndrome ,COMPARATIVE studies ,REGRESSION analysis - Abstract
Copyright of Arquivos Brasileiros de Oftalmologia is the property of Arquivos Brasileiros de Oftalmologia and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
- Published
- 2020
- Full Text
- View/download PDF
22. Análise do ensino da oftalmoscopia direta nos cursos de graduação em Medicina do Estado de Mato Grosso.
- Author
-
Esidio, Alisson Vitor and Mosena de Angeloni, Carolina Ramos
- Subjects
- *
MEDICAL students , *OPHTHALMOSCOPY , *LITERATURE reviews , *SELF-perception , *CONFIDENCE intervals , *FIRST aid training , *SCHOOLS - Abstract
Objective: direct ophthalmoscopy teaching is receiving less attention during graduation, which results in doctors without confidence to perform the exam. Therefore, the self-perception of students from medical schools of Mato Grosso about the direct ophthalmoscopy and the main factors responsible for the insecurity on performing it was analyzed. Methods: a literature review was done using the databases Pubmed, Scielo and Biblioteca Virtual em Saúde, then a questionnaire was applied, through the snowball method and after favorable assent of the Ethics Committee, to medical students from Mato Grosso who were regularly enrolled in the fifth or sixth year of the course. Statistical analysis was performed on the SPSS 20 software, considering a confidence interval of 95%. Results: it was verified that the proportion of students that have had classes about direct ophthalmoscopy was superior in public schools (p < 0,001); that the majority of students does not believe that their schools provide adequate conditions for learning the exam (p = 0,001); that 10,5% considerate themselves knowledgeable about theory and practice regarding direct ophthalmoscopy (p = 0,004); that few training during graduation is the main factor that hinders learning the exam; and that this results in underconfidence at performing it. Conclusion: direct ophthalmoscopy is not receiving the deserved importance during medical graduation in the state of Mato Grosso. With these results, measures can be taken to improve the teaching-learning process of the technique, which can bring benefit to the population. [ABSTRACT FROM AUTHOR]
- Published
- 2020
- Full Text
- View/download PDF
23. Lack of association between provocative test-based intraocular pressure parameters and functional loss in treated glaucoma patients.
- Author
-
Gracitelli, Carolina Pelegrini Barbosa, Paranhos Jr., Augusto, Dias, Diego Torres, Almeida, Izabela, Scoralick, Ana Luiza Bassoli, Prata, Tiago Santos, Ushida, Michele, Kanadani, Fábio Nishimura, and Dorairaj, Syril
- Subjects
INTRAOCULAR pressure ,OPEN-angle glaucoma ,VISUAL fields ,GLAUCOMA ,DRINKING water ,GLAUCOMA surgery - Abstract
Copyright of Arquivos Brasileiros de Oftalmologia is the property of Arquivos Brasileiros de Oftalmologia and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
- Published
- 2019
- Full Text
- View/download PDF
24. Effect of accelerated corneal crosslinking on ocular response analyzer waveform-derived parameters in progressive keratoconus.
- Author
-
Murat Uzel, Mehmet, Koc, Mustafa, Can, Cigdem, Polat, Sibel, Yılmazbaş, Pelin, and Ileri, Dilek
- Subjects
KERATOCONUS ,DRY eye syndromes ,VISUAL acuity ,BIOMECHANICS ,OPTICAL instruments - Abstract
Copyright of Arquivos Brasileiros de Oftalmologia is the property of Arquivos Brasileiros de Oftalmologia and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
- Published
- 2019
- Full Text
- View/download PDF
25. Medição do eixo visual através de dois métodos diferentes: quantificação e diferenças para medição da corda μ
- Author
-
Rodrigues, Pablo Felipe, Moscovici, Bernardo Kaplan, Lamazales, Luciano, Freitas, Marcela Mara Silva, Gomes, José Álvaro Pereira, Nosé, Walton, and Campos, Mauro Silveira
- Subjects
Cornea ,Percepção visual ,Córnea ,Imagem óptica ,Diagnostic techniques ,ophthalmological ,Segmento anterior do olho ,Visual perception ,Pupil ,Anterior eye segment ,Técnicas de diagnóstico oftalmológico ,Pupila ,Optical imaging - Abstract
Purpose: To compare the differences between the apparent and actual chord μ. Methods: In this prospective, comparative, non-randomized, and non-interventional study, imaging examinations using Pentacam and the HD Analyzer were performed in the same room under the same scotopic conditions. The inclusion criteria were patients aged 21-71 years, able to provide informed consent, myopia up to 4D, and anterior topographic astigmatism up to 1D. Patients using contact lenses, those with previous eye diseases or surgeries, corneal opacities, corneal tomographic changes, or suspected keratoconus were excluded. Results: Altogether, 116 eyes of 58 patients were analyzed. The patients’ mean age was 30.69 (±7.85) years. In the correlation analyses, Pearson’s correlation coefficient of 0.647 indicates a moderate positive linear relationship between apparent and actual chord μ. The mean actual and apparent chord μ were 226.21 ± 128.53 and 278.66 ± 123.90 μm, respectively, with a mean difference of 52.45 μm (p=0.01). The analysis of mean pupillary diameter resulted in 5.76 mm using the HD Analyzer and 3.31 mm using the Pentacam. Conclusions: We found a correlation between the two measurement devices, and even though we found considerable differences, both can be used in daily practice. Given their differences, we should respect their peculiarities as well. RESUMO Objetivo: Comparar as diferenças entre a chord aparente μ e o chord real μ. Métodos: Estudo prospectivo, comparativo, não randomizado e não intervencionista. Os exames de imagem (Pentacam e HD Analyzer) foram realizados na mesma sala e nas mesmas condições escotópicas. Os critérios de inclusão foram idade de 21 a 71 anos; compreensão do termo de consentimento; miopia até 4D e astigmatismo topográfico anterior até 1D. Os critérios de exclusão foram usuários de lentes de contato; pacientes com doenças oculares prévias ou cirurgias; opacidades da córnea; a presença de alterações tomográficas da córnea ou suspeita de ceratocone. Resultados: Em nosso estudo foram analisados 116 olhos de 58 pacientes. A média de idade foi de 30,69 anos (± 7,85). Análises de correlação foram desenvolvidas e o coeficiente de correlação de Pearson (0,647) indica uma relação linear positiva moderada entre as variáveis. A média do chord μ real foi 226,21 ± 128,53 μm e a média do chord μ média foi 278,66 ± 123,90 μm, com diferença média de 52,45 μm (p=0,01). A análise do diâmetro pupilar médio apresentou: 5,76mm no HD Analyzer e 3,31mm no Pentacam. Conclusões: Entendemos a existência de uma diferença significativa entre os métodos e assim a medida de ambos os dispositivos com base em princípios diferentes devemos respeitar suas peculiaridades. Como encontramos correlação entre as duas medidas, acreditamos que ambas podem ser utilizadas na prática diária.
- Published
- 2023
26. Tear film osmolarity variation between weeks in healthy and dry eye disease subjects
- Author
-
Pena-Verdeal, Hugo, Garcia-Queiruga, Jacobo, Sabucedo-Villamarin, Belen, Giraldez, María J., and Yebra-Pimentel, Eva
- Subjects
Lágrimas ,Ophthalmology ,Diagnostic techniques ,ophthalmological ,Síndromes do olho seco ,Osmolar concentration ,Tears ,General Medicine ,Técnicas de diagnóstico oftalmológico ,Concentração osmolar ,Dry eye syndromes - Abstract
Purpose: The possible variability in diagnostic test results is a statistical feature of dry eye disease patients. The clinician should consider tear film variations over time since the timing of tear film measurements is important for proper diagnosis. The purpose of the present study was to analyze the inter-week variation of osmolarity measurement in healthy and dry eye disease participants. Methods: Based on the Dry Eye Workshop II (DEWS-II) diagnostic methodology report criteria, a battery of tests (Ocular Surface Disease Index [OSDI] questionnaire, breakup time, and corneal staining) was administered to rule out the presence of dry eye disease. A total of 40 qualified volunteers were recruited into two groups: with only 20 healthy and 20 dry eye disease participants. The inter-week variation of osmolarity in the two groups was measured using a TearLab osmometer in two sessions one-week apart. The differences between the results were calculated. Results: There were no significant differences in osmolarity between the two sessions for either the healthy (paired t-test; p=0.085) or dry eye disease (paired t-test; p=0.093) participants. Moreover, there was no significant correlation between the means and differences in either session on healthy (Pearson correlation: r=0.020; p=0.935) or dry eye disease (Pearson correlation: r=-0.022; p=0.928) participants. In session 1, there was a significant difference in osmolarity values between groups (unpaired t-test; p=0.001), but no difference was found in session 2 (unpaired t-test; p=0.292). Conclusions: The present study discovered no inter-week variation in the tear film osmolarity of healthy and dry eye disease participants classified based on the DEWS-II criteria. RESUMO Objetivo: A possível variabilidade nos resultados de testes diagnósticos é uma característica estatística dos pacientes com síndrome do olho seco. O médico deve considerar as variações do filme lacrimal ao longo do tempo, pois o momento em que o filme lacrimal é medido pode ser crítico para o diagnóstico adequado. O objetivo deste estudo foi analisar a variação semanal da osmolaridade do filme lacrimal em participantes saudáveis e em outros com síndrome do olho seco. Métodos: Com base nos critérios da metodologia de diagnóstico do relatório da Dry Eye Workshop II (DEWSII), foi aplicada uma bateria de testes (questionário do índice de doença da superfície ocular [OSDI], tempo de ruptura do filme lacrimal e coloração da córnea) para descartar a presença de síndrome do olho seco. Um total de 40 voluntários qualificados foi recrutado e distribuído em dois grupos de 20 participantes saudáveis e 20 participantes com síndrome do olho seco. A variação da osmolaridade entre semanas foi medida com um osmômetro TearLab em duas sessões com uma semana de intervalo nos dois grupos. As diferenças entre os resultados foram então calculadas. Resultados: Não foram encontradas diferenças significativas na osmolaridade entre as medidas obtidas nas duas sessões, nem no grupo de participantes saudáveis (teste de t pareado; p=0,085), nem no de participantes com síndrome do olho seco (teste de t pareado; p=0,093). Não foi detectada nenhuma correlação significativa entre as médias e diferenças entre as duas sessões entre participantes saudáveis (correlação de Pearson: r=0,020, p=0,935) e aqueles com síndrome do olho seco (correlação Pearson: r=-0,022, p=0,928). Foi encontrada uma diferença significativa nos valores de osmolaridade entre os dois grupos na primeira sessão (teste de t não pareado; p=0,001), mas nenhuma diferença foi encontrada na segunda sessão (teste de t não pareado; p=0,292). Conclusões: O presente estudo não encontrou variação entre semanas consecutivas na osmolaridade do filme lacrimal em participantes saudáveis e com síndrome do olho seco, classificados com base nos critérios do DEWSII.
- Published
- 2023
- Full Text
- View/download PDF
27. Efficacy of probing for congenital nasolacrimal duct obstruction in a private tertiary hospital: 10-year experience.
- Author
-
Schroff Machado, Daniela Cristina, Ferreira Castro, Raiane Cristina, Alves de Souza, Bruna Angelina, Melo Dias, Mirna de, de Oliveira Lima, Amanda Feitoza, Léda, Rayssa Medeiros, and Fontenele Feijó, Eduardo Damous
- Subjects
- *
LACRIMAL apparatus , *DACRYOCYSTORHINOSTOMY , *OPERATIVE surgery , *HOSPITALS - Abstract
Objetive: To evaluate the success rate of initial and repeated probing as treatment approach for congenital nasolacrimal duct obstruction (CNLDO) in children between 2 and 46 months. Methods: A restrospective review of 73 children diagnosed with CNLDO who underwent probing of the NLD from March 2010 to 2020 was conducted. Data were colected from Hospital Oftalmológico de Anápolis in Anápolis, Goiás. Results: The procedure was performed in 90 eyes. The study sample was constituted of 36 males and 37 females. Bilateral involvement occurred in 18 (24.6%) children whereas 55 (75.3%) of them were unilaterally affected. The age ranges of the patients were divided into 4 groups: A - up to 6 months old (5.5% of the eyes), B - 7 to 12 months (27.5%), group C - 13 to 24 months (39.5%) and group D - older than 24 months (26.4%). The mean age of the sample was 18.6 months. Initial probing obtained an overall success rate of 88.8% and group B showed the best percentage (96%) from all age ranges. The second intervention had a lower outcome, successfuly in 55.5% of the cases. Conclusion: All age ranges showed high success rates for initial probing, although there was a decrease in subsequent procedures outcomes. Our results demonstrate that the success rate for primary probing is not affected by age. [ABSTRACT FROM AUTHOR]
- Published
- 2021
- Full Text
- View/download PDF
28. Practical user manual for Corneal Confocal Microscope
- Author
-
Funchal, Cassia [UNIFESP], Allemann, Norma [UNIFESP], and Wakamatsu, Tais Hiromi [UNIFESP]
- Subjects
Microscopia Confocal ,Córnea ,Técnicas de diagnóstico oftalmológico - Abstract
Introdução: A microscopia confocal da córnea é um método que permite avaliar estruturas celulares in vivo e fornece informações relevantes para o diagnóstico e decisão terapêutica. No Brasil, a técnica é pouco difundida e necessita treinamento de usuários. Objetivo: Elaborar um manual prático para os usuários de microscópios confocais de córnea de dois fabricantes, além de um manual ilustrado orientando passo-a-passo para usuários não treinados. Métodos: A descrição da rotina de uso e dos passos necessários para a realização da microscopia confocal da córnea nos equipamentos ConfoScan 4 (Nidek) e Heidelberg Retina Tomograph 3 Módulo de Córnea Rostock (Heidelberg). Para a confecção dos manuais práticos envolveu: coleta de informações e de imagens durante o acompanhamento da realização do exame por diferentes examinadores treinados e a estruturação de manuais práticos descrevendo e ilustrando a rotina correta para o preparo da sala e do material para o exame, modo de ligar o aparelho e preparo do dispositivo, manuseio do programa de software, registro, preparo do paciente, cuidados após o exame e arquivamento. No Manual Ilustrado para o aparelho Heidelberg Módulo de Córnea foram inseridas imagens ilustrativas da córnea normal e de casos de patologias da córnea. Os manuais permitem a realização do exame de maneira padronizada, auxiliando na aquisição de imagens significativas para cada tipo de patologia, mesmo para um examinador sem treinamento prévio na técnica. Resultados: A confecção de um manual prático para cada equipamento ConfoScan 4 e Heidelberg Módulo de Córnea e um manual ilustrado para o último citado. Conclusão: Os manuais elaborados para microscopia confocal de córnea permitiram uma padronização do método de exame, estabelecendo uma rotina para o mapeamento das camadas da córnea e a análise de imagens adquiridas Introduction: Corneal confocal microscopy is a method that allows the evaluation of cellular structures in vivo and provides relevant information for diagnosis and therapeutic decision. In Brazil, the technique is not widespread and requires user training. Objective: Develop a practical manual for users of corneal confocal microscopes from two manufacturers, as well as an illustrated manual providing step-by-step guidance for untrained users. Methods: The description of the routine of use and the steps required to perform the confocal microscopy of the cornea in the ConfoScan 4 (Nidek) and Heidelberg Retina Tomograph 3 Rostock Cornea Module (Heidelberg) equipment. The preparation of practical manuals involved: collection of information and images during the monitoring of the examination performed by different trained examiners and the structuring of practical manuals describing and illustrating the correct routine for preparing the room and material for the examination, how to turn on the device and prepare the device, handling the program of software, registration, patient preparation, post-exam care, and archiving. In the Illustrated Manual for the Heidelberg Cornea Module device, illustrative images of the normal cornea and cases of corneal pathologies were inserted. The manuals allow the examination to be performed in a standardized way, helping to acquire significant images for each type of pathology, even for an examiner without previous training in the technique. Results: The preparation of a practical manual for each ConfoScan 4 and Heidelberg Cornea Module equipment and an illustrated manual for the last one. Conclusions: The manuals developed for corneal confocal microscopy allowed for a standardization of the examination method, establishing a routine for mapping the corneal layers and analyzing the acquired images.
- Published
- 2022
29. Acordo de medições do diâmetro da córnea obtidas por um biômetro óptico e um topógrafo com base em Plácido
- Author
-
Teixeira,Eloisa Gomes Rosario M., Gomes,Beatriz Fiuza, Santana,João Dominice, Santhiago,Marcony R, Costa,Adroaldo Alencar, and Moraes Jr,Haroldo V
- Subjects
Ophthalmology ,Axial length ,Diagnostic techniques ,Ophthalmological ,Comprimento axial do olho ,Topografia da córnea ,Ophthalmological surgical procedures ,General Medicine ,Corneal topography ,Procedimentos cirúrgicos oftalmológicos ,Técnicas de diagnóstico oftalmológico ,eye - Abstract
Purpose: The purpose of this study was to compare the white-to-white distance measurements of two devices (IOL Master 500 and Atlas corneal topographer) commonly used in clinical practice to determine if they were interchangeable. Providing information on instrument interchangeability could eliminate several unnecessary tests and consequently reduce the economic burden for the patient and society. Methods: In this prospective, comparative case series, the white-to-white distance was measured by independent examiners using the Atlas topographer (Carl Zeiss Meditec) and the IOL Master 500 (Carl Zeiss Meditec). One eye each of 184 patients was tested. Statistical analyses were performed using a paired t-test, Pearson correlation analysis, and Bland-Altman analysis to compare the measurement methods. Results: The mean white-to-white distance measurements with the Atlas topographer and the IOL Master 500 were 12.20 ± 0.44 mm and 12.12 ± 0.41 mm, respectively (p
- Published
- 2022
30. Ocular surface assessment and morphological alterations in meibomian glands with non-contact meibography in electronic cigarette smokers
- Author
-
Kalayci, Mustafa, Cetinkaya, Ersan, Yaprak, Lütfiye, Yigit, Kenan, Suren, Elcin, Dogan, Berna, and Erol, Muhammet Kazim
- Subjects
Diagnostic techniques ,ophthalmological ,Electronic nicotine delivery systems ,Fumar/efeitos adversos ,Meibomian glands ,Vaping/efeitos adversos ,Smoking/adverse effects ,Vaping/adverse effects ,Meibomian gland dysfunction/diagnosis ,Sistemas eletrônicos de liberação de nicotina ,Técnicas de diagnóstico oftalmológico ,Glândulas tarsais ,Disfunção da glândula tarsal/diagnostico - Abstract
Purpose: The study aimed to evaluate the ocular surface and meibomian gland morphology in electronic cigarette (e-cigarette) smokers. Methods: The upper and lower eyelids of 25 male e-cigarette smokers and 25 healthy male non-smoker patients were evaluated using Sirius meibography. Meibomian glands loss was automatically calculated using Phoenix meibography imaging software module, with the result obtained as percentage loss. Ocular Surface Disease Index (OSDI) questionnaire, tear breakup time test, and Schirmer II test were administered and performed in all cases. Results: The mean e-cigarette smoking duration was 4.9 ± 0.9 (range, 3.4-7) years. While the mean Schirmer II test value was 9.16 ± 2.09 mm in e-cigarette group, it was 11.20 ± 2.14 mm in control group (p=0.003). Mean tear breakup time was 6.96 ± 2.31 seconds in e-cigarette group and 9.84 ± 2.13 seconds in control group (p=0.002). The mean OSDI value was 28.60 ± 6.54 and 15.16 ± 7.23 in e-cigarette and control groups, respectively (p
- Published
- 2022
31. Comparison of linear measurements of optic cup-to-disk ratio obtained with RTVue OCT and digital retinography.
- Author
-
RIBEIRO JR., VALDENIR, RIBEIRO, CRISTIANE FARIAS, ÁVILA, MARCOS P., and MAGACHO, LEOPOLDO
- Subjects
OPTIC disc ,OPTICAL coherence tomography ,RETINAL imaging ,GLAUCOMA diagnosis ,OPTIC nerve - Abstract
Copyright of Arquivos Brasileiros de Oftalmologia is the property of Arquivos Brasileiros de Oftalmologia and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
- Published
- 2017
- Full Text
- View/download PDF
32. Best waveform score for diagnosing keratoconus
- Author
-
Allan Luz, Bruno Machado Fontes, Bernardo Lopes, Isaac Ramos, Fernando Faria Correia, Paulo Schor, and Renato Ambrósio Jr.
- Subjects
Córnea/fisiopatologia ,Ceratocone/diagnóstico ,Biomecânica/fisiologia ,Dilatação patológica ,Técnicas de diagnóstico oftalmológico ,Ophthalmology ,RE1-994 - Abstract
PURPOSE: To test whether corneal hysteresis (CH) and corneal resistance factor (CRF) can discriminate between keratoconus and normal eyes and to evaluate whether the averages of two consecutive measurements perform differently from the one with the best waveform score (WS) for diagnosing keratoconus. METHODS: ORA measurements for one eye per individual were selected randomly from 53 normal patients and from 27 patients with keratoconus. Two groups were considered the average (CH-Avg, CRF-Avg) and best waveform score (CH-WS, CRF-WS) groups. The Mann-Whitney U-test was used to evaluate whether the variables had similar distributions in the Normal and Keratoconus groups. Receiver operating characteristics (ROC) curves were calculated for each parameter to assess the efficacy for diagnosing keratoconus and the same obtained for each variable were compared pairwise using the Hanley-McNeil test. RESULTS: The CH-Avg, CRF-Avg, CH-WS and CRF-WS differed significantly between the normal and keratoconus groups (p
- Published
- 2013
- Full Text
- View/download PDF
33. Alpins and thibos vectorial astigmatism analyses: proposal of a linear regression model between methods
- Author
-
Giuliano de Oliveira Freitas, Joel Edmur Boteon, Mario Jose Carvalho, and Rogerio de Melo Costa Pinto
- Subjects
Facoemulsificação ,Astigmatismo ,Limbo da córnea ,Implante de lentes intraoculares ,Técnicas de diagnóstico oftalmológico ,Ophthalmology ,RE1-994 - Abstract
PURPOSE: To determine linear regression models between Alpins descriptive indices and Thibos astigmatic power vectors (APV), assessing the validity and strength of such correlations. METHODS: This case series prospectively assessed 62 eyes of 31 consecutive cataract patients with preoperative corneal astigmatism between 0.75 and 2.50 diopters in both eyes. Patients were randomly assorted among two phacoemulsification groups: one assigned to receive AcrySof®Toric intraocular lens (IOL) in both eyes and another assigned to have AcrySof Natural IOL associated with limbal relaxing incisions, also in both eyes. All patients were reevaluated postoperatively at 6 months, when refractive astigmatism analysis was performed using both Alpins and Thibos methods. The ratio between Thibos postoperative APV and preoperative APV (APVratio) and its linear regression to Alpins percentage of success of astigmatic surgery, percentage of astigmatism corrected and percentage of astigmatism reduction at the intended axis were assessed. RESULTS: Significant negative correlation between the ratio of post- and preoperative Thibos APVratio and Alpins percentage of success (%Success) was found (Spearman's ρ=-0.93); linear regression is given by the following equation: %Success = (-APVratio + 1.00)x100. CONCLUSION: The linear regression we found between APVratio and %Success permits a validated mathematical inference concerning the overall success of astigmatic surgery.
- Published
- 2013
- Full Text
- View/download PDF
34. Manifestaciones clínicas y evolución a largo plazo de tres casos de rosácea ocular atendidos en un hospital de alta especialidad del sureste de México
- Author
-
Nina Méndez-Domínguez, Rodrigo Diaz-Novelo, Fiona Xacur-García, Paulina Moreno-Arjona, and Linnete Herrera-David
- Subjects
medicine.medical_specialty ,lcsh:Arctic medicine. Tropical medicine ,lcsh:RC955-962 ,business.industry ,lcsh:R ,lcsh:Medicine ,trasplante ,Ocular rosacea ,medicine.disease ,Dermatology ,General Biochemistry, Genetics and Molecular Biology ,técnicas de diagnóstico oftalmológico ,pronóstico ,030207 dermatology & venereal diseases ,03 medical and health sciences ,0302 clinical medicine ,Rosacea ,rosácea ,oftalmopatías ,030221 ophthalmology & optometry ,medicine ,Etiology ,business - Abstract
La rosácea es una alteración cutánea crónica que se ha asociado con factores etiológicos inespecíficos y diversas manifestaciones sistémicas. La rosácea cutánea suele evolucionar a rosácea ocular del 6 al 72 % de los pacientes. Al no existir criterios específicos que la caractericen, la rosácea ocular implica un reto diagnóstico. Para fortalecer la sospecha diagnóstica temprana, se presentan tres casos de pacientes con evolución clínica distinta, pero que tuvieron en común el retraso diagnóstico, lo que se tradujo en manifestaciones graves y daño ocular extenso.
- Published
- 2020
- Full Text
- View/download PDF
35. Analysis of direct ophthalmoscopy teaching in Medical graduation courses of Mato Grosso State
- Author
-
Alisson Vitor Esidio and Carolina Ramos Mosena de Angeloni
- Subjects
Ophthalmoscopy ,Ensino ,Ophthalmology ,Students, Medical ,Aprendizagem ,Teaching ,Diagnostic techniques, ophthalmological ,Learning ,Estudantes de Medicina ,Oftalmoscopia ,Técnicas de diagnóstico oftalmológico ,RE1-994 - Abstract
Resumo Objetivo: o ensino da oftalmoscopia direta vem recebendo menos atenção na graduação, o que resulta em médicos sem confiança para realizá-la. Diante disso, foi analisada a autopercepção dos acadêmicos dos cursos de medicina de Mato Grosso sobre a oftalmoscopia direta e os principais fatores responsáveis pela insegurança em executá-la. Métodos: foi realizada a revisão bibliográfica nas bases Pubmed, Scielo e Biblioteca Virtual em Saúde, sendo construído um questionário aplicado, pelo método bola de neve e após parecer favorável do Comitê de Ética, a acadêmicos de medicina do Mato Grosso que estavam cursando regularmente o quinto ou sexto ano do curso. A análise estatística foi realizada no software SPSS 20, considerando intervalo de confiança de 95%. Resultados: verificou-se que a proporção de acadêmicos que tiveram aulas sobre a oftalmoscopia direta foi superior em universidades públicas (p < 0,001); que a maioria dos alunos não acredita que suas escolas forneçam as condições adequadas para o aprendizado do exame (p = 0,001); que 10,5% se consideram conhecedores da teoria e prática da oftalmoscopia direta (p = 0,004); que a falta de treinamento durante a graduação é o principal fator que dificulta o aprendizado do exame; e que isso resulta em falta de confiança em realizar o mesmo. Conclusão: a oftalmoscopia direta não tem recebido a devida importância durante a graduação em medicina no estado de Mato Grosso. Com tais resultados, pode-se tomar medidas que melhorem o ensino-aprendizado da técnica, o que posteriormente trará benefício para a população. Abstract Objective: direct ophthalmoscopy teaching is receiving less attention during graduation, which results in doctors without confidence to perform the exam. Therefore, the self-perception of students from medical schools of Mato Grosso about the direct ophthalmoscopy and the main factors responsible for the insecurity on performing it was analyzed. Methods: a literature review was done using the databases Pubmed, Scielo and Biblioteca Virtual em Saúde, then a questionnaire was applied, through the snowball method and after favorable assent of the Ethics Committee, to medical students from Mato Grosso who were regularly enrolled in the fifth or sixth year of the course. Statistical analysis was performed on the SPSS 20 software, considering a confidence interval of 95%. Results: it was verified that the proportion of students that have had classes about direct ophthalmoscopy was superior in public schools (p < 0,001); that the majority of students does not believe that their schools provide adequate conditions for learning the exam (p = 0,001); that 10,5% considerate themselves knowledgeable about theory and practice regarding direct ophthalmoscopy (p = 0,004); that few training during graduation is the main factor that hinders learning the exam; and that this results in underconfidence at performing it. Conclusion: direct ophthalmoscopy is not receiving the deserved importance during medical graduation in the state of Mato Grosso. With these results, measures can be taken to improve the teaching-learning process of the technique, which can bring benefit to the population.
- Published
- 2020
36. Diretrizes brasileiras para cicloplegia e midríase em crianças
- Author
-
Curi,Ian, Nakayama,Simone Akiko, Pereira,Érika Mota, Hopker,Luisa Moreira, Ejzenbaum,Fábio, Barcellos,Ronaldo Boaventura, Ferreira,Rosane da Cruz, Cronemberger,Monica Fialho, Mckeown,Craig A, and Rossetto,Júlia Dutra
- Subjects
Mydriatics ,ophthalmological ,diagnostic techniques ,Refração ocular ,Infant ,Criança ,General Medicine ,Midríase ,Recém-nascido ,Técnicas de diagnóstico oftalmológico ,ocular ,Refraction ,Ophthalmology ,newborn ,Child - Abstract
Cycloplegia is crucial for reliable pediatric ophthalmology examinations. This document provides a recommendation for pediatric cycloplegia and mydriasis for Brazilian ophthalmologists. This article was developed based on literature reviews; the clinical experience of Brazilian specialists, as obtained through questionnaires; and the consensus of the Expert Committee of the Brazilian Pediatric Ophthalmology Society. According to the best evidence and formulations available in Brazil, this committee recommends the use of one drop of 1% cyclopentolate plus one drop of 1% tropicamide in children older than 6 months and two drops of 1% tropicamide 0-5 minutes apart for those younger than 6 months. Mydriasis may be increased by a single drop of 2.5% phenylephrine. For retinopathy of prematurity screening, the recommendation is 0.5% or 1% tropicamide, administered two or three times, 5 minutes apart, and 2.5% phenylephrine, used preferably once. In all scenarios, we recommend the use of a prior drop of 0.5% proxymetacaine. RESUMO A cicloplegia é crucial para um exame oftalmológico pediátrico acurado. Este documento visa a fornecer uma recomendação para cicloplegia e midríase pediátrica para oftalmologistas brasileiros. Foi desenvolvido com base em revisão literária, na experiência clínica de especialistas brasileiros, por meio de questionários, e no consenso do comitê de especialistas da Sociedade Brasileira de Oftalmologia Pediátrica (SBOP). De acordo com as melhores evidências, este comitê recomenda o uso de uma gota de ciclopentolato 1%, mais uma gota de tropicamida 1% em crianças maiores de 6 meses e duas gotas de tropicamida 1% com intervalo de 0-5 minutos para menores de 6 meses. A midríase pode ser potencializada por uma gota de fenilefrina 2,5%. Para o rastreamento da retinopatia da prematuridade, a recomendação é tropicamida 0,5 ou 1%, duas ou três vezes, com 5 minutos de intervalo, e 2,5% de fenilefrina, preferencialmente uma vez. O uso prévio de proxymetacaína 0,5% é sempre recomendado.
- Published
- 2022
- Full Text
- View/download PDF
37. Evaluation of efficacy of new lens nucleus fragmenting forceps in cataract surgery
- Author
-
Alves, Milton Ruiz
- Subjects
TÉCNICAS DE DIAGNÓSTICO OFTALMOLÓGICO - Published
- 2022
38. Comparação entre acuidade visual e photoscreening como métodos de triagem visual para crianças em idade escolar
- Author
-
Roberta Lílian Fernandes de Sousa, Bruno Schiavoni Funayama, Luciana Catâneo, Carlos Roberto Padovani, and Silvana Artioli Schellini
- Subjects
Ambliopia ,Acuidade visual ,Criança ,Técnicas de diagnóstico oftalmológico ,Ophthalmology ,RE1-994 - Abstract
OBJETIVO: Avaliar a sensibilidade do aparelho photoscreener na detecção de alterações oculares em crianças informantes, comparando os dados à acuidade visual obtida pela tabela E de Snellen. MÉTODOS: Foram avaliadas 500 crianças de idades entre 5 e 12 anos, de escola do município de Botucatu, estado de São Paulo. As crianças foram submetidas ao teste de acuidade visual pela tabela E de Snellen e foram fotografadas utilizando-se o aparelho photoscreenerTM system model MTI-PS100, seguindo-se a análise das fotos obtidas. RESULTADOS: Houve concordância negativa (criança com boa acuidade visual e teste negativo com o photoscreener) em 81,0%; concordância positiva (acuidade visual alterada e teste positivo) em 7,6% e não houve concordância de resultados em 11,0% dos casos. CONCLUSÃO: A avaliação comparativa entre o método da acuidade visual pela tabela E de Snellen e o photocreener para detecção de problemas visuais mostrou alta concordância. Os autores sugerem entretanto, a triagem usando tabelas de acuidade visual quando se trata de crianças informantes, devido aos custos com o aparelho.
- Published
- 2012
- Full Text
- View/download PDF
39. Avaliação das alterações biomecânicas da córnea antes e após lasik em pacientes míopes e hipermetrópes utilizando Moriá® Sub-Bowman's Keratomileusis (SBK)
- Author
-
Bruno de Freitas Valbon, Jorge Siqueira Silva, Isaac C. Oliveira Ramos, Rosane Correa, Ana Laura Canedo, Rodrigo Teixeira Santos, and Renato Ambrósio Jr
- Subjects
Córnea ,Biomecânica ,Miopia ,Hiperopia ,Ceratomileuse assistida por excimer laser in situ ,Técnicas de diagnóstico oftalmológico ,Ophthalmology ,RE1-994 - Abstract
OBJETIVO: Avaliar e comparar as alterações biomecânicas da córnea por meio do Ocular Response Analyzer® (ORA Reichert Ophtalmics Instruments, Buffalo, New York, USA) antes e após Lasik com Moriá ® Sub Bowman Keratomileusis (SBK) One Use Plus (OUP) em pacientes míopes e hipermetrópes. MÉTODOS: Foram estudados 33 olhos, sendo 19 olhos míopes e 14 olhos hipermetrópes submetidos à cirurgia refrativa com técnica Lasik com flap fino (100 µ) utilizando Moriá SBK OUP. O ORA foi realizado no pré-operatório e 1 mês após a cirurgia para avaliar a biomecânica da córnea. O CH (Corneal Hysteresis), CRF (Corneal Resistance Factor), IOPg (goldmann gold standard, Goldmann correlated intraocular pressure) a IOPcc (corneal compensated intraocular pressure) e mais 38 variáveis biomecânicas da córnea derivadas do sinal de resposta foram avaliados. O Teste de Kolmogorov-Smirnov foi utilizado para avaliar a distribuição normal. O teste de Wilcoxon foi utilizado para comparar as variáveis antes e após a cirurgia para cada grupo. As diferenças entre as medidas pré e pós-operatórias dos olhos míopes foram comparadas com as diferenças obtidas nos olhos hipermetrópes, utilizando-se o teste de Mann-Whitney. Foi considerado como estatisticamente significante p < 0,05%. RESULTADOS: Houve diferença significativa antes e após Lasik em olhos míopes e hipermetrópes na variável IOPg(Wilcoxon, p
- Published
- 2012
- Full Text
- View/download PDF
40. Análise da camada de fibras nervosas da retina pela tomografia de coerência óptica em pacientes com anemia falciforme
- Author
-
Leiser Franco, Luis Alexandre Rassi, Marcos Pereira Ávila, and Leopoldo Magacho
- Subjects
Glaucoma ,Anemia falciforme ,Fibras nervosas ,Retina ,Técnicas de diagnóstico oftalmológico ,Lasers ,Tomografia de coerência óptica ,Ophthalmology ,RE1-994 - Abstract
OBJETIVO: Avaliar a camada de fibras nervosas da retina (CFNR) em pacientes com anemia falciforme sem glaucomaatravés da tomografia de coerência óptica (OCT). MÉTODOS: O estudo selecionou pacientes com anemia falciforme (homozigotos SS), provenientes do ambulatório de hematologia da Universidade Federal de Goiás, e voluntários normais controlados por raça e idade. Para serem incluídos, os integrantes de ambos os grupos deveriam apresentar acuidade visual e" 20/30 sem correção, pressão intraocular (Pio) d" 21mmHg, campo visual SITA Standard 24-2 e disco óptico sem alterações sugestivas de glaucoma. Os pacientes eram encaminhados para exame da CFNR por meio do OCT, estratégia Fast RNFL, e os dados comparados entre os grupos. RESULTADOS: Foram selecionados 24 pacientes (24 olhos) por grupo. A média da idade foi de 25,2 ± 14,9 anos no grupo da anemia falciforme e 20,5 ± 12,5 anos nos pacientes normais (p=0,09). Não houve diferença estatisticamente significativa ao se comparar a espessura média da CFNR entre o grupo de estudo e o grupo controle para todos os quadrantes pesquisados. CONCLUSÃO: O presente estudo não evidenciou lesão da CFNR aferida através da Tomografia de Coerência Óptica em pacientes com anemia falciforme sem alterações oftalmológicas presentes ao exame clínico.
- Published
- 2011
- Full Text
- View/download PDF
41. Avaliação da pressão intraocular através do ocular response analyzer antes e após cirurgia de facoemulsificação
- Author
-
Bruno de Freitas Valbon, Renata Siqueira Silva, Daniela Jardim, Ana Laura Canedo, Marcelo Palis, and Renato Ambrósio Junior
- Subjects
Biomecânica ,Pressão intraocular ,Córnea ,Facoemulsificação ,Técnicas de diagnóstico oftalmológico ,Ophthalmology ,RE1-994 - Abstract
OBJETIVO: Verificar a variação das medidas pressóricas através do Ocular Response Analyzer (ORA, Reichert): IOPg (gold standard, Goldmann correlated intraocular pressure) e IOPcc (corneal compensated intraocular pressure) antes e após a cirurgia de catarata por facoemulsificação. MÉTODOS: Estudo observacional prospectivo envolvendo 47 olhos de 36 pacientes que se submeteram à cirurgia de catarata por facoemulsificação com implante de lente intraocular. A Pressão intraocular compensada da córnea (IOPcc) e correlacionada com Goldmann (IOPg), foram medidos pelo Ocular Response Analyzer (ORA); As medidas foram realizadas no pré-operatório, 1º dia e 30º dia após a cirurgia de facoemulsificação. O Teste de Kolmogorov-Smirnov foi utilizado para avaliar a distribuição normal. Diferenças obtidas entre as medidas obtidas através do Ocular Response Analyzer foram avaliadas pelo T-test (Student's paired t-test). Foi considerado como estatisticamente significante p < 0,05%. RESULTADOS: As médias da IOPcc no pré-operatório, no primeiro dia e no trigésimo dia após a cirurgia de facoemulsificação e implante de LIO foram de 15.6 (±3.06), 15.5 (±3.14) , e 15.71 (±4.34). A média de IOPg no pré-operatório foi de 14.7 (± 3.0), no primeiro dia após cirurgia 12.9 (± 3.1) e no trigésimo dia 13.4 (± 3.7). Houve diferença significativa entre IOPg (PRE X D1) com p < 0,01. CONCLUSÃO: Observamos uma diminuição da IOPg no pós-operatório imediato em córneas com edema após facoemulsificação. Logo, ressaltamos a importância da biomecânica na medida da Pio.
- Published
- 2011
- Full Text
- View/download PDF
42. Valores da exoftalmometria média na população adulta da região do Grande ABC, São Paulo/Brasil Normal exophthalmometric values in adult population of ABC Region, Sao Paulo/Brazil
- Author
-
Nadia Ajub Moysés, Lúcia Míriam Dumont Lucci, Nilson Lopes da Fonseca Júnior, and José Ricardo Carvalho Lima Rehder
- Subjects
Exoftalmia ,Técnicas de diagnóstico oftalmológico ,Valores de referência ,Exophthalmos ,Diagnostic techniques, ophthalmological ,Reference values ,Ophthalmology ,RE1-994 - Abstract
OBJETIVO: Estabelecer padrões de normalidade dos valores da exoftalmometria de ambos os olhos e da distância entre os rebordos orbitários laterais (base) em adultos jovens da população do Grande ABC São Paulo/Brasil. MÉTODOS: Realizou-se a exoftalmometria com o exoftalmômetro de Hertel, em 129 pacientes do sexo feminino e 75 do sexo masculino, na faixa etária de 25 a 55 anos. Os pacientes foram separados em três grupos raciais (brancos, negros e pardos). RESULTADOS: A variação da exoftalmometria encontrada na população em estudo foi de 10 a 23mm, média de 15,57 ±2,43mm. No sexo feminino a média foi de 15,42 ±2,40mm e no masculino, 15,83 ±2,47mm. Não se encontrou uma relação estatisticamente significativa entre os sexos feminino e masculino (p=0,25). Na raça branca a média foi de 15,57 ±2,46mm, na negra foi de 16,20 ±2,70mm e na parda foi de 15,02 ±2,01mm. A diferença foi estatisticamente significativa (p=0,008) entre as raças negra e parda. A medida da base variou de 104 a 125mm (média de 113,91 ±4,37mm). A diferença entre homens e mulheres foi estatisticamente significativa (pPURPOSE: To determine the normal exophthalmometry of both eyes and of the distance between lateral orbital rims (the base measurement) in young adults from ABC Region, São Paulo/Brazil. METHODS: Exophthalmometry, by Hertel's exophthalmometer, was made in 129 female and 75 male subjects, age ranging from 25 to 55 years. The subjects were divided in three groups of races (white, black and mulatto). RESULTS: The values of exophthalmometry ranged from 10 to 23mm, mean 15,57 ±2,43mm. In female the mean was 15,42 ±2,40mm and in male, 15,83 ±2,47mm. There is no statistically significant difference between female or male (p=0,25). In whites subjects the mean was 15,57 ±2,46mm, in black was 16,20 ±2,70mm and in mulatto was 15,02 ±2,01mm. There was a statistically significant difference between blaks and mulattos (p=0,008). The base measurement ranged from 104 to 125mm (mean 113,91 ±4,37mm). There was a statistically significant difference between males and females (p
- Published
- 2010
- Full Text
- View/download PDF
43. Perfil morfofuncional de pacientes com retinopatia diabética sem baixa acuidade visual severa em hospital público de referência em diabetes no Brasil Morpho-functional profile of patients with diabetic retinopathy without severe loss of visual acuity in a public hospital of reference in diabetes in Brazil
- Author
-
Alípio de Sousa Neto, Élida Maria de Araújo Pereira, Regina Cândido Ribeiro dos Santos, and Procópio Miguel dos Santos
- Subjects
Retinopatia diabética ,Tomografia de coerência óptica ,Edema macular ,Técnicas de diagnóstico oftalmológico ,Retina ,Acuidade visual ,Diabetic retinopathy ,Optical coherence tomography ,Macular edema ,Ophthalmological diagnostic techniques ,Visual acuity ,Ophthalmology ,RE1-994 - Abstract
OBJETIVO: Demonstrar o perfil morfofuncional da avaliação de pacientes com retinopatia diabética sem baixa acuidade visual severa em hospital público de referência em endocrinologia, determinando nesta amostra, a relação entre o tempo de diabetes, idade e acuidade visual com a espessura retiniana medidas pela tomografia de coerência óptica (OCT) e retinografia (RET). MÉTODOS: Foi realizado estudo prospectivo, linear, em corte transversal de 61 pacientes consecutivos com retinopatia diabética registrados no Hospital Regional de Taguatinga (HRT), e encaminhados pelos serviços de oftalmologia e endocrinologia. Pacientes foram submetidos à avaliação oftalmológica completa, incluindo história clínica, aferição da acuidade visual com correção e com buraco estenopeico. 109 olhos de 55 pacientes foram então submetidos à OCT e RET para avaliação da presença ou ausência de edema macular pela RET e da avaliação quantitativa (medidas da espessura retiniana das 9 regiões classificadas pelo Early Tratment Diabetic Retinophaty Study - ETDRS) e da avaliação qualitativa (presença ou ausência de edema retiniano pela fenda central, número 1). RESULTADOS: O tempo médio de diabetes entre os sujeitos da pesquisa foi de 12 anos, com idade variando de 23 a 86 anos; 51% eram do gênero feminino, e 49% do masculino. A avaliação da acuidade visual melhorou em 47% (51/109) dos pacientes com buraco estenopeico. Somente 22% (24/109) dos olhos apresentavam acuidade visual corrigida de 20/20 com correção e sem edema macular diabético (EMD). Em 83% (91/109) dos casos havia concordância e em 17% (18/109 olhos) havia discordância em relação à presença/ausência de EMD no perfil da avaliação morfológica realizada pela OCT e pela RET nos olhos do grupo amostral. CONCLUSÃO: Não houve correlação estatística significante entre a espessura retiniana e o tempo de diabetes. O grupo da oftalmologia teve 5 vezes mais chance de apresentar EMD do que o grupo da endocrinologia.OBJECTIVE: To demonstrate the morpho-functional profile of the evaluation of patients with diabetic retinopathy without severe loss of visual acuity in a public hospital of reference in endocrinology, determining in this sample, the relation between the time of diabetes, age and visual acuity with the retinal thickness measured by the optical Coherence tomography (OCT) and fundus picture (FP). METHODS: Prospective, linear study was carried through, in transversal cut of 61 consecutive patients with diabetic retinopathy registered in the HRT, and refered from the services of ophthalmology and endocrinology. Patients had been submitted to a complete ophthalmic evaluation including clinical history, visual acuity with correction and pin hole. The patients who had presented diabetic retinopathy, with transparent media, without previous surgery, nor previous Laser photocoagulation and with visual acuity better than 20/100 at Snelen scale, had been included in the study. After the elimination of the patients who had not obeyed the inclusion/exclusion criteria 109 eyes of 55 patients then had been submitted the OCT and FP for evaluation of the presence or absence of edema by the FP and of the quantitative evaluation (measured of the retinal thickness of the 9 regions of the pelo Early Tratment Diabetic Retinophaty Study (ETDRS), and of the qualitative evaluation (presence or absence of retinal edema for the central slit, number 1). RESULTS: The average time of diabetes was of 12 years, varying of 23 to 86 years old. 51% were female, and 49% male. The OCT demonstrated discrete reduction of the retinal thickness with elapsing of the age. The patients of the ophthalmology had greaters values of retinal thickness of what of the group of the endocrinology. The evaluation of the visual acuity improved with pin hole in 47% (51/109). The endocrinology group were 45% (23/50) of the eyes and the ophthalmology group were 55% (28/59). Only 22% (24/109) of the eyes presented corrected visual acuity of 20/20 with correction and without Diabetic Macular Edema (DME). In 83% (91/109) of the cases it had agreement and in 17% (18/109 eyes) it had discord in relation the presence/absence of DME in the profile of the morphologic evaluation carried through by the optic coherence tomography and the fundus picture, in the eyes of the amostral group. CONCLUSION: It did not have statistical significant correlation between the retinal thickness and the time of diabetes.
- Published
- 2010
- Full Text
- View/download PDF
44. Evaluation and visual prognosis in patients with optic nerve drusen
- Author
-
Yosbelkis Martín Páez, Lillian Gloria León Veitía, Yaney González Yglesias, Carlos E. Mendoza Santiesteban, Tamara de las Mercedes Galbán Lueje, and Pedro Mario Font Aranda
- Subjects
drusen del disco óptico ,técnicas de diagnóstico oftalmológico ,evaluación/estadística & datos numéricos ,pronóstico ,Medicine - Abstract
A descriptive, prospective and cross-sectional study was carried out with the aim of determining the variables predictive of the visual acuity by means of a follow up of the psychophysical studies and the diagnostic means in patients with papillary drusen, taking into account their location. The universe of study was formed by 20 patients who were treated at the neuro-ophthalmology consulting rooms of the Ramon Pando Ferrer Ophthalmology Hospital in Havana City during the period from November 2006 to November 2007. These patients were selected according to the inclusion and exclusion criteria. The investigation relied on the correlation of variables, which were represented in charts with the previous implementation of a statistical analysis in the program SPSS, version 11. The location of the drusen in the optic nerve was determined according to sectors of the disc with a prevalence of the preliminary temporal ones, with 47.5 percent.
- Published
- 2010
45. Estudo do comportamento da PIO de 24 horas e frequência de glaucoma em pacientes com síndrome da apnéia obstrutiva do sono Study on 24 hours IOP study and glaucoma frequency in patients with obstructive sleep apnea syndrome
- Author
-
Maria Rosa Bet de Moraes Silva and Silke Anna Theresa Weber
- Subjects
Apnéia do sono tipo obstrutiva ,Pressão intra-ocular ,Glaucoma de ângulo aberto ,Técnicas de diagnóstico oftalmológico ,Sleep apnea, obstructive ,Intraocular pressure ,Glaucoma ,open-angle ,Diagnostic techniques ,ophthalmological ,Ophthalmology ,RE1-994 - Abstract
OBJETIVO: Determinar a frequência de glaucoma e avaliar o comportamento da pressão intraocular (PIO) de 24 horas em pacientes portadores da síndrome da apnéia obstrutiva do sono (SAOS). MÉTODOS: Foi realizado estudo transversal em 11 pacientes consecutivos portadores de SAOS diagnosticados por polissonografia. Foram analisados dados demográficos: idade, sexo, raça/cor, peso, altura e doenças associadas. Os pacientes foram submetidos à avaliação oftalmológica completa que incluiu campo visual e também avaliação da pressão intraocular (PIO) de 24 horas com tonômetro de aplanação às 9h, 12h, 15h, 18h, 24h e 6h deitado e sentado. O critério para diagnóstico de glaucoma foi alteração de campo visual (CV) compatível com glaucoma e uma ou mais das seguintes alterações: relação escavação disco ³ 0,7, hemorragia, defeito em cunha, vaso em baioneta, sinal de Hoyt, assimetria > que 0,2 entre as escavações dos dois olhos. O ângulo devia ser aberto sem alterações. RESULTADOS: 9 (82%) de 11 pacientes apresentaram glaucoma ou suspeita de glaucoma, sendo 9% glaucoma de pressão normal e 73% suspeita de glaucoma por apresentarem alterações do nervo óptico ou hipertensão ocular. A média dos valores de PIO dos 11 pacientes apresentou-se mais elevada às 6 horas quando os pacientes estavam deitados. Ocorreram flutuações de PIO ³ 5 mmHg em 7 (64%) dos pacientes sendo que ocorreram flutuações de até 14 mmHg e picos de PIO de até 32 mmHg. CONCLUSÃO: A SAOS pode ser um fator de risco importante para o esenvolvimento de glaucoma principalmente de pressão normal. Pacientes com SAOS devem ser referidos para o oftalmologista e os oftalmologistas devem estar atentos para a associação de distúrbios do sono em pacientes com glaucoma de ângulo aberto.PURPOSE: To determine the frequency of glaucoma and evaluate the behavior of 24-hour intraocular pressure in patients with the obstructive sleep apnea syndrome (OSAS). METHODS: Eleven consecutive patients with OSAS, diagnosed by polysonography, were avaliated in a cross sectional study. Demographic data were analyzed: age, sex, race/color, weight, height and associated diseases. The patients were submitted to complete ophthalmologic examination, including the visual field, as well as to 24-hour intra-ocular pressure (IOP) evaluation by an applanation tonometer at 9h, 12h, 15h, 18h, 24h and 6h in the lying and sitting positions. The diagnostic criterion for glaucoma was alteration of the visual field (VF) compatible with glaucoma and one or more of the following alterations: cup-disc ratio ³ 0.7, hemorrhage, wedge-shaped defect, bayonet-shaped vessels, Hoyt's sign, asymmetry > than 0.2 between cup/disc ratio of the eyes. The angle should be opened without alterations. RESULTS: 9 (82%) of 11 patients showed glaucoma or were suspected to have glaucoma, 9% of which exhibited normal tension glaucoma and 73% were suspected to have glaucoma for presenting alterations in the optic nerve or ocular hypertension. The mean for the IOP values of the 11 patients was observed to be the highest at 6 o'clock, when they were lying down. Variations of IOP ³ 5 mmHg occurred in 7 (64%) of the patients, and variations of up to 14 mmHg and IOP peaks of up to 32 mmHg were observed. CONCLUSION: OSAS may be an important risk factor for the development of glaucoma, particularly that of normal tension glaucoma. Patients with OSAS must be referred to an ophthalmologist and those professionals must be attentive to the association of sleep disorders in patients with open-angle glaucoma.
- Published
- 2009
- Full Text
- View/download PDF
46. Estudo comparativo entre imagens ultra-sonográficas obtidas com sondas de 10MHz e 20 MHz na avaliação de anormalidades do segmento posterior do globo ocular Comparative study of ultrasound images obtained with 10MHz and 20 MHz probes in the evaluation of the abnormalities of the posterior segment of the globe
- Author
-
Marcio Henrique Mendes, Alberto Jorge Betinjane, Adhele Furlani de Sá Cavalcante, Vera Regina Cardoso Castanheira, Cheng Te Cheng, and José Carlos Eudes Carani
- Subjects
Oftalmopatias ,Doenças orbitárias ,Técnicas de diagnóstico oftalmológico ,Corpo vítreo ,Retina ,Eye diseases ,Orgbital diseases ,Diagnostic techniques, ophthalmological ,Vitreous body ,Ophthalmology ,RE1-994 - Abstract
A ecografia se constitui em método importante na avaliação de anormalidades do segmento posterior do globo ocular. OBJETIVO: Comparar as vantagens e desvantagens da sonda de 10 e 20 MHz da ultra-sonografia B-scan, na avaliação de imagens do segmento posterior do globo ocular. MÉTODOS: Pacientes acompanhados no ambulatório do Hospital das Clínicas da USP (HCFMUSP) entre fevereiro de 2006 e abril de 2007 foram submetidos a exame ultra-sonográfico usando o aparelho CINE-Scan® (Quantel Medical Inc.) com sondas de 10 e 20 MHz. Os pacientes foram examinados por três oftalmologistas experientes, em decúbito dorsal, após instilação de colírio de tetracaína a 1%, inicialmente com a sonda sobre as pálpebras e em seguida diretamente em contato com a esclera ou córnea. As imagens obtidas com sondas de 10 e 20 MHz foram comparadas entre si, durante e após a realização do exame. RESULTADOS: A sonda de 20 MHz mostrou-se superior na avaliação da detecção, forma e limites de estruturas do pólo posterior e a de 10 MHz avaliou com mais detalhes o humor vítreo. Não foram encontradas diferenças nas imagens obtidas com exame transpalpebral ou transescleral com a sonda de 10 MHz. Com a sonda de 20 MHz, as imagens obtidas em contato direto com o globo ocular apresentaram melhor qualidade. CONCLUSÕES: As sondas de 10 e 20 MHz têm diferentes intervalo de alcance ideal, assim como diferentes meios específicos de aquisição de melhores imagens.The ultrasound is an important method in the evaluation of abnormalities of the posterior segment of the eye. PURPOSE: To compare the advantages and disadvantages of 10 and 20 MHz probe on B- scanning ultra-sonography in evaluation of vitreous and posterior pole diseases, providing recommendations for their use. METHODS: Patients from Hospital das Clinicas of the University of São Paulo (HC-FMUSP), attended between February 2006 and April 2007, were submitted to ultrasound exams using CINE-Scan® (Quantel Medical Inc) B-scan with 10 and 20MHz probe. The patients were examined by three experienced ophthalmologists, in horizontal dorsal position, after instillation of tetracaine 1% drops, first with the probe in direct contact with eyelids, and then with the probe placed directly in contact with the sclera or cornea. Theimages obtained were compared immediately during and after the examination. RESULTS: The 20 MHz probe reveled a superior resolution to study details, like shape and limits, on the posterior pole, and the 10 MHz probe provided better evaluation on vitreous humor. There were no differences if the exam was performed on eyelids or directly on sclera with the 10 MHz probe, but with the 20 MHz probe, the images had better resolution when the probe was used in direct contact with the eye. CONCLUSIONS: The 10 and 20 probes have different ideal range of reach, as different better specific means of image achieving.
- Published
- 2009
- Full Text
- View/download PDF
47. Estesiometria corneana pós cirurgia fotorrefrativa Esthesiometry corneal after surgery photorefractive
- Author
-
Alessandro Perussi Garcia, Fernando Antonio Gualiardo Tarcha, Vicente Vitiello Neto, Edmundo Velasco Martinelle, and Jose Ricardo Carvalho Lima Rehder
- Subjects
Miopia ,Córnea ,Ceratomileuse assistida por excimer laser in situ ,Ceratectomia fotorrefrativa ,Lasers de excimer ,Sensação ,Técnicas de diagnostico oftalmológico ,Myipoia ,Myiopia ,Cornea ,Keratomileusis, laser in situ ,Keratectomy photorefractive ,Lasers, excimer ,Sensation ,Diagnostic techniques, ophthalmological ,Ophthalmology ,RE1-994 - Abstract
OBJETIVO: Avaliar as alterações que ocorrem na sensibilidade corneanas após as cirurgias de LASIK e PRK MÉTODOS: Estudo prospectivo onde foram avaliados 60 olhos de 30 pacientes submetidos a LASIK bilateral simultaneamente e mais 30 olhos de 15 pacientes submetidos a PRK bilateral simultaneamente. De acordo com a quantidade de ablação intra-operatórias, os olhos foram divididos em dois grupos: Grupo 1 (menor que 40 µm) e Grupo 2 (Maior que 40 µm). A sensibilidade corneana foi medida na região central da córnea pelo estesiometro Cochet Bonnet® no pré operatório e após 30, 90 e 180 dias da cirurgias. RESULTADOS: A sensibilidade corneana na LASIK apresentou-se diminuída durante os três primeiros meses retornando as valores pré operatórios aos 6 meses; E de acordo com a quantidade de ablação o Grupo 1 apresentou diferença estatisticamente significante em relação ao Grupo 2 durante os três primeiros meses; No entanto a PRK recuperou seus valores pré operatório aos três meses e de acordo com a quantidade de ablação o Grupo 1 apresentou diferença estatisticamente significante somente no primeiro mês de pós operatório. CONCLUSÃO: A LASIK apresentou sensibilidade menor em relação ao PRK durante os 3 primeiros meses e somente aos 6 meses os valores da sensibilidade corneana foram similares; Os resultados também sugerem que a quantidade de ablação está relacionada com a diminuição da sensibilidade corneana durante os primeiros meses em ambas as técnicas cirúrgicas, principalmente na LASIK.PURPOSE: To evaluate the alterations that occur on the cornea sensitivity after Lasik and PRK surgery. METHODS: Prospective studies have evaluated60 eyes from 30 patients subjected simultaneously to bilateral Lasik and 30 eyes from 15 patients subjected simultaneously to bilateral PRK. According to the amount of inner operatory ablation the eyes were divided into two groups: Group I (< 40 µm) and group II (> 40µm). The cornea sensitivity was measured in the central region of the cornea on the pre operatory and then again at 30, 90 and 180 days after the surgery with the esthesiometer. RESULTS: The cornea sensitivity in Lasik presented itself in a minor way during the first three months, returning to pre operatory values at six months; and according to the amount of ablation group I presented statistically significant difference in comparison to group II during the first three months; however PRK recovered its pre operatory values at three months and according to the amount of ablation group I presented statistically significant difference only on the first month of pre operatory. CONCLUSION: Lasik showed the least sensitivity in comparison to PRK during the first three months, only at six months the sensitivity values were similar to each other; the results suggest that the result of ablation endangers the cornea sensitivity during the first months on both surgical techniques especially Lasik.
- Published
- 2009
- Full Text
- View/download PDF
48. Ensino de oftalmologia na graduação médica: Estudo comparativo de aprendizado na oftalmoscopia direta com oftalmoscópio convencional e de campo amplo (Panoptic) Teaching ophthalmology at university medical undergraduate course: Comparative study of direct ophthalmoscopy between conventional ophthalmoscope and wide field ophthalmoscope (panoptic) as evaluation method
- Author
-
Eduardo de França Damasceno, Nadyr Antonia Pereira Damasceno, and Adroaldo de Alencar Costa Filho
- Subjects
Oftalmoscopia ,Técnicas de diagnóstico oftalmológico ,Educação médica ,Questionário ,Ophthalmoscopy ,Diagnostic techniques ,ophtalmological ,Education, medical ,Questionnaires ,Ophthalmology ,RE1-994 - Abstract
Objetivo: Comparação da facilidade de aprendizado na realização da oftalmoscopia direta pelos alunos da graduação médica com o uso do oftalmoscópio convencional e do Panoptic. Métodos: Realizou- se um estudo comparativo da facilidade de aprendizado entre o uso do oftalmoscópio convencional e do panoptic para a realização do exame de fundo de olho de pacientes normais e com determinadas alterações específicas de fundo de olho. Foi usado para tal aferição um questionário formulado pelos autores e respondido pelos alunos da graduação na primeira e na oitava semana do curso. Resultados: Na primeira semana do curso, dos 60 alunos avaliados somente 1.60% tiveram maior facilidade de manipulação do aparelho com o panoptic, contrastando com 10.35% com o uso do convencional. Na oitava semana, 43.33% dos alunos demonstrou maior facilidade de manipulação com o uso do panoptic, contrastando com 17% com o uso do convencional. O teste estatístico de Kruskal Wallis se revelou de significância expressiva ( p < 0,05). Conclusão:: O oftalmoscópio de campo amplo (panoptic) necessita de um tempo de aprendizagem de uso um pouco maior em relação ao convencional, porém após este período facilita o aprendizado da oftalmoscopia direta por melhorar a observação das estruturas fundoscópicas.Purpose: Comparison of the skill to teach the direct ophthalmoscopy class supported by fellows of medical graduation course using two examination methods: conventional ophthalmoscope and wide field ophthalmoscope (panoptic). Methods: Assessment of the competence to learn using a survey after eye fundus examination with conventional ophthalmoscope and wide field ophthalmoscope (panoptic). The group searched was composed of 60 students of university medical graduation course. The survey was applied during the first and eighth week of ophthalmogical class of medical graduation. The evaluation of competence to learning was token in as needing to help teachers to examination the eye fundus during the class, and the competence to manipulate the ophthalmoscopes. Tables and statical test (Kruskal Wallis) was performed to demonstrate the results analysis. Results: In the first week of ophthalmological class, only 1.60% of the students chose the panoptic ophthalmoscope, while the same score of 10.35% chosen with the conventional ophthalmoscope. In the eighth week of ophthalmological class the competence score with the panoptic ophthalmoscope raised to 43.33%, while conventional ophthalmoscope score stayed at 17% . The statistical analysis of Kruskal Wallis test revealed a positive significance (p< 0,05). Conclusion: The panoptic wide field ophthalmoscope needed a longer time to learn how to manipulate and observe the eye fundus, although after this time, the panoptic showed more competence and improved the eye fundus examination.
- Published
- 2009
- Full Text
- View/download PDF
49. Prevalência da retinopatia diabética em unidade do Programa de Saúde da Família Prevalence of the diabetic retinopathy in a Family's Health Program unity
- Author
-
Murielem Fernandes Guedes, Arlindo José Freire Portes, Abelardo de Souza Couto Junior, Juliana dos Santos Nunes, and Regina Célia Coutinho Oliveira
- Subjects
Diabetes Mellitus ,Retinopatia diabética ,Programa Saúde da Família ,Cegueira ,Técnicas de diagnóstico oftalmológico ,Oftalmoscopia ,Diabetic Mellitus ,Diabetic Retinopathy ,Family health program ,Blindness ,Diagnostic techniques, ophthalmological ,Ophthalmoscopy ,Ophthalmology ,RE1-994 - Abstract
OBJETIVO: Determinar a prevalência da retinopatia diabética na população cadastrada no Programa de Saúde da Família (PSF) - Parque Prazeres, em Campos dos Goytacazes, RJ, e o nível de conhecimento desta doença pelos pacientes diabéticos. MÉTODOS: Estudo descritivo de série de casos onde foram convidados a participar do trabalho de pesquisa todos os 72 pacientes diabéticos cadastrados através da ficha A (ficha de cadastro das famílias) do PSF estudado. Para a realização do estudo aceitaram participar 46 (64%) dos 72 pacientes. Os pacientes foram submetidos ao exame de acuidade visual, sendo posteriormente aplicado um questionário para a avaliação do nível de conhecimento das alterações visuais causadas pelo diabetes, em seguida foi realizado o exame de fundoscopia direta. O estudo estatístico foi feito com auxílio do programa Microsoft Excel e Bioestat 5.0 RESULTADOS: A prevalência da retinopatia diabética foi de 19,5% ( IC 95% entre 8,1 e 31%); 13% possuíam retinopatia diabética não proliferativa e 6,5% retinopatia diabética proliferativa. De acordo com critério da Organização Mundial de Saúde: 8,5% foram considerados cegos e 8,9% com baixa visão no momento do exame ocular. Setenta e dois por cento dos pacientes afirmaram ter conhecimento que o diabetes poderia causar alterações visuais, mas 80% não sabiam dos exames necessários para diagnóstico e 65% nunca foram anteriormente submetidos ao exame de fundoscopia. CONCLUSÃO: Programas de prevenção à cegueira pela retinopatia diabética no PSF são justificados, considerando que a prevalência desta doença nas comunidades carentes assistidas pode estar em níveis elevados, como a observada neste estudo. A melhora do conhecimento dos pacientes sobre o risco de perda de visão e exames oftalmológicos periódicos poderá contribuir para um melhor controle da retinopatia diabética.OBJECTIVE: Determine the diabetic retinopathy prevalence in a Family's Health Program unity in Parque Prazeres - Campos dos Goytacazes, RJ, and the level of patient's knowledge about diabetes visual impairment. METHODS: Seventy two diabetic patients were selected, but only 46 attended the research. The patients were chosen based on Family's Health Program medical registers. They were submitted to visual acuity examination and afterward to a questionnaire in order to evaluate their knowledge level about visual impairment. Then, they were submitted to a direct fundoscopic examination. Statistical studies were done based on Microsoft Excel and Bioestat 5.0 RESULTS: Diabetic retinopathy prevalence was about 19,5% (CI 95% between 8,1 and 31%); 13% showed non proliferative diabetic retinopathy and 6,5% showed proliferative retinopathy. In accordance with World Health's Organization criteria: 8,5% were considered blind and 8,9% with low vision at the moment of ocular examination. Seventy two percent of patients had previous knowledge that diabetes could cause visual reduction, but 80% didn't know the necessary exams to diagnose it and 65% never were previously submitted to ophthalmoscopy. CONCLUSION: Blindness prevention programs by diabetic retinopathy in Family Health Programs are justified considering that the retinopathy diabetic prevalence in assisted communities could be high, as was in this study. The improvement of patient knowledge about the vision threatening risk and ophthalmological exams can allow a better retinopathy diabetic control.
- Published
- 2009
- Full Text
- View/download PDF
50. Comparison of central corneal edema and visual recovery between liquefaction and conventional phacoemulsification in soft cataracts Comparação do edema de córnea central e da recuperação visual após facoemulsificação por liquefação e convencional em cataratas moles
- Author
-
Celso Takashi Nakano, Wilson Takashi Hida, Newton Kara-Jose Junior, Antonio Francisco Pimenta Motta, Alexandre Reis, Mauricio Pamplona, Reinaldo Fujita, Iris Yamane, Ricardo Holzchuh, and Amaryllis Avakian
- Subjects
Facoemulsificação ,Extração de catarata ,Técnicas, medidas e equipamentos de medição ,Técnicas de diagnóstico oftalmológico ,Biometria ,Phacoemulsification ,Cataract extraction ,Techniques, measures, measurement equipment ,Diagnostic techniques, ophthalmological ,Biometry ,Ophthalmology ,RE1-994 - Abstract
PURPOSE: The aim of the present study is to assess central corneal edema and visual recovery after cataract surgery performed according to two technologies: conventional ultrasonic and liquefaction (Aqualase®). METHODS:This is a prospective contralateral study in wich 20 patients with comparable preoperative conditions were submitted to cataract surgery were evaluated. Preoperative assessment involved complete ophthalmological examination and the study included patients with bilateral cataracts up to grade 2, according to the Lens Opacity Classification System II. The same cristaline fracture technique was used in all cases, and surgical procedures were performed by the same experienced surgeon, using two technologies: liquefaction or conventional phacoemulsification. Postoperative central corneal edema was measured by corneal optical pachymetry (Orbscan II®) on the 1st, 3rd, 7th and 10th postoperative days. RESULTS:None of the 20 patients submitted to surgery was lost during the postoperative follow-up or excluded from the analysis. On the first postoperative, the visual acuity average was 0.031 logMAR in the Aqualase® group and 0.043 logMAR in the conventional surgery group. No statistical difference was detected in the assessment of visual acuity throughout the postoperative period. Central corneal pachymetry varied from 543.93 + 34.69 preoperatively to 545.08 ± 25.67 on the last day of follow-up in the Aqualase® group, and from 543.13 + 30.62 to 536.08 + 34.89 in the conventional technique group, without statistical significance. CONCLUSION:This study suggests that both techniques are equally effective for surgery on lenses with grade I or II cataract, and that they provide similar results in terms of visual recovery and central corneal edema.OBJETIVO: Avaliar o edema corneano central e a recuperação visual após cirurgia de catarata realizada através de duas tecnologias: ultrassônica convencional e liquefação (Aqualase®). MÉTODOS: Estudo retrospectivo com análise contralateral, onde 20 pacientes se submeteram à facectomia sob condições pré-operatórias comparáveis. A avaliação pré-operatória envolveu exame oftalmológico completo com graduação da catarata de acordo com o Lens Opacity Classification System II, e foram incluídos no estudo pacientes com catarata nuclear bilateral até grau II. A mesma técnica cirúrgica foi realizada em todos os casos pelo mesmo cirurgião, utilizando as duas tecnologias: liquefação e facoemulsificação convencional. As medidas do edema corneano pós-operatório foram realizadas com paquímetro óptico corneano (Orbscan II®) nos dias 1, 3, 7 e 10 de pós-operatório. RESULTADOS: Nenhum dos pacientes inicialmente inscritos no estudo foi excluído ou perdido durante o seguimento. No primeiro dia pós-operatório a acuidade visual média foi de 0.031 logMAR no grupo de Aqualase e 0.043 logMAR no grupo convencional. Nenhuma diferença estatisticamente significativa foi detectada na análise de acuidade visual durante o período pós-operatório. A paquimetria corneana central variou de 543.93 + 34.69 no pré-operatório para 545.08 ± 25.67 no último dia de acompanhamento no grupo de Aqualase e de 543.13 + 30.62 para 536.08 + 34.89 no grupo convencional, sem diferença estatisticamente significativa. CONCLUSÃO: O estudo sugere que as duas técnicas são igualmente eficaz para as cirurgias nucleares graus I e II, além de apresentarem resultados similares em relação ao edema corneano central e à recuperação visual.
- Published
- 2009
- Full Text
- View/download PDF
Catalog
Discovery Service for Jio Institute Digital Library
For full access to our library's resources, please sign in.