11 results on '"T. Denimal"'
Search Results
2. Non-regular Sampling and Compressive Sensing for Gearbox Monitoring
- Author
-
T. Bovkun, C. Parellier, Yosra Marnissi, T. Denimal, Dany Abboud, and J. Gehin
- Subjects
Compressed sensing ,Sampling (signal processing) ,Computer science ,Bandwidth (signal processing) ,Condition monitoring ,Nyquist–Shannon sampling theorem ,Order (ring theory) ,Nyquist frequency ,Algorithm ,Signal - Abstract
Vibration-based condition monitoring is a powerful field to achieve preventive maintenance and control the efficiency of mechanical systems. The common monitoring scheme consists of capturing vibration signals at a sufficiently high sampling frequency to consider the dynamic and kinematic properties of the machine, and then condition indicators are constructed and saved or sent to a ground-based surveillance station. A major drawback of such an approach is that these indicators may not be sufficient to establish an accurate diagnosis, and the signal itself is needed in various situations. As the frequency rate of vibration signals and, consequently, their size highly depends on the highest frequency to be monitored, it is generally set high in order to respect the Nyquist theorem. As a consequence, sending these data can be compromised because of the limited bandwidth of the transmission channel. This paper proposes a non-regular sampling strategy via compressive sensing to significantly reduce the sampling frequency (below the Nyquist limit) and the data size, while preserving enough information for diagnosis. It is based on the hypothesis that the measured signal consists of a sum of sinusoids corrupted by some random Gaussian noises. The signal recovery problem from random samples is then formulated through an \({{\ell }}_{{{2}}} - {{\ell }}_{{{1}}}\) optimization problem, which is solved via the iterative shrinking-thresholding algorithm. At last, the potentiality of the suggested approach is demonstrated on real vibration signals measured from a spur gearbox with a spalling fault that progresses over 12 days.
- Published
- 2021
- Full Text
- View/download PDF
3. V stenting technique with covered stents for the management of ostial circumflex perforation: Good or bad idea?
- Author
-
Denimal T, Vincent F, Juthier F, Pamart T, Moussa MD, Schurtz G, Pontana F, Van Belle E, and Delhaye C
- Abstract
We report the case of a redo Ross surgery complicated by an ostial left circumflex occlusion requiring emergent percutaneous coronary intervention. The latter was complicated by coronary perforation treated by two covered stents with V-stenting technique. After immediate success, the clinical course was marked by acute stent thrombosis requiring emergent coronary bypass., Learning Objectives: Ostial left circumflex perforation is a rare and potentially fatal complication that is challenging to manage. V stenting technique with two covered stents could be used as a life-saving procedure, but is associated with a high thrombotic risk., Competing Interests: The authors have reported that they have no relationships relevant to the contents of this paper to disclose., (© 2023 Japanese College of Cardiology. Published by Elsevier Ltd. All rights reserved.)
- Published
- 2023
- Full Text
- View/download PDF
4. Negative Impact of TET2 Mutations on Long-Term Survival After Transcatheter Aortic Valve Replacement.
- Author
-
Lassalle F, Duployez N, Vincent F, Rauch A, Denimal T, Rosa M, Labreuche J, Dombrowicz D, Staels B, Preudhomme C, Susen S, Van Belle E, and Dupont A
- Abstract
Clonal hematopoiesis of indeterminate potential (CHIP) is considered as being a novel age-related risk factor for cardiovascular diseases. By capture-sequencing of a 67-gene panel, we established a large spectrum of CHIP in 258 patients with aortic valve stenosis undergoing transcatheter aortic valve replacement (TAVR) and assessed their association with long-term survival after TAVR. One or several CHIP variants in 35 genes were identified in 68% of the cohort, DNMT3A and TET2 being the 2 most frequently mutated genes. Patients carrying a TET2 -CHIP-driver variant with low variant allele frequency (2%-10%) had a significant decrease in overall survival 5 years after TAVR., Competing Interests: Dr Staels is supported by grants from the Fondation Leducq convention 6CVD01 “Defining and targeting epigenetic pathways in monocytes and macrophages that contribute to cardiovascular disease,” the European Genomic Institute for Diabetes (EGID, ANR-10-LABX-0046), and is a recipient of an Advanced ERC Grant (694717). All other authors have reported that they have no relationships relevant to the contents of this paper to disclose.PerspectivesCOMPETENCY IN MEDICAL KNOWLEDGE: AVS is an elderly pathology mediated by inflammation. CHIP has been recently described as a novel age-related risk factor for cardiovascular diseases. This study describes in a cohort of 258 patients a large profile and a high prevalence of CHIP-driver genes in AVS. Moreover, patients carrying TET2 mutations with low VAF (2%-10%) have a decreased overall survival at 5 years after TAVR. These findings contribute to the understanding of the pathogenesis of AVS and might help decision making in the management of patients with AVS undergoing TAVR. TRANSLATIONAL OUTLOOK: Additional functional studies in relevant preclinical models are still needed to unravel the exact mechanisms by which CHIP-driver variants contribute to AVS and impact the clinical prognosis after TAVR, especially in TET2. Our findings need to be validated in larger studies of consecutive patients before being used for decision making in the management of patients with severe AVS undergoing TAVR. There are a number of studies that showed that TET2 deficiency in murine models leads to an enhanced inflammation, particularly via IL-1β and NLRP3 inflammasome. Our study emphasizes the fact that IL-1β and the inflammasome could be novel therapeutic targets in AVS and for the improvement of survival after TAVR for patients who are carrying TET2 somatic variants., (© 2023 The Authors.)
- Published
- 2023
- Full Text
- View/download PDF
5. [TAVR : Imaging for an optimal femoral approach].
- Author
-
Vincent F, Denimal T, Delhaye C, Pamart T, Pontana F, and Van Belle E
- Subjects
- Humans, Femoral Artery diagnostic imaging, Lower Extremity, Computed Tomography Angiography, Tomography, X-Ray Computed methods, Transcatheter Aortic Valve Replacement methods
- Abstract
Both computed tomography (CT) angiography and vascular ultrasound have a major role before and during a transfemoral approach to TAVR. CT angiography will determine whether the patient is eligible for a femoral approach. Peri-procedural arterial ultrasound will be helpful to improve safety and optimize results during the femoral approach. Being able to interpret both of these imaging modalities is of paramount importance for any interventional cardiologist who practices structural interventions., (Copyright © 2022. Published by Elsevier Masson SAS.)
- Published
- 2022
- Full Text
- View/download PDF
6. Cerebral Microbleeds During Transcatheter Aortic Valve Replacement: A Prospective Magnetic Resonance Imaging Cohort.
- Author
-
Van Belle E, Debry N, Vincent F, Kuchcinski G, Cordonnier C, Rauch A, Robin E, Lassalle F, Pontana F, Delhaye C, Schurtz G, JeanPierre E, Rousse N, Casari C, Spillemaeker H, Porouchani S, Pamart T, Denimal T, Neiger X, Verdier B, Puy L, Cosenza A, Juthier F, Richardson M, Bretzner M, Dallongeville J, Labreuche J, Mazighi M, Dupont-Prado A, Staels B, Lenting PJ, and Susen S
- Subjects
- Aged, Aortic Valve surgery, Aortic Valve Stenosis diagnostic imaging, Aortic Valve Stenosis surgery, Female, Fluoroscopy, Hemostatics, Humans, Magnetic Resonance Imaging, Male, Prospective Studies, Quality of Life, Risk Factors, Treatment Outcome, von Willebrand Factor, Cerebral Hemorrhage diagnostic imaging, Cerebral Hemorrhage epidemiology, Cerebral Hemorrhage etiology, Transcatheter Aortic Valve Replacement adverse effects
- Abstract
Background: Cerebral microbleeds (CMBs) have been observed in healthy elderly people undergoing systematic brain magnetic resonance imaging. The potential role of acute triggers on the appearance of CMBs remains unknown. We aimed to describe the incidence of new CMBs after transcatheter aortic valve replacement (TAVR) and to identify clinical and procedural factors associated with new CMBs including hemostatic measures and anticoagulation management., Methods: We evaluated a prospective cohort of patients with symptomatic aortic stenosis referred for TAVR for CMBs (METHYSTROKE [Identification of Epigenetic Risk Factors for Ischemic Complication During the TAVR Procedure in the Elderly]). Standardized neurologic assessment, brain magnetic resonance imaging, and analysis of hemostatic measures including von Willebrand factor were performed before and after TAVR. Numbers and location of microbleeds on preprocedural magnetic resonance imaging and of new microbleeds on postprocedural magnetic resonance imaging were reported by 2 independent neuroradiologists blinded to clinical data. Measures associated with new microbleeds and postprocedural outcome including neurologic functional outcome at 6 months were also examined., Results: A total of 84 patients (47% men, 80.9±5.7 years of age) were included. On preprocedural magnetic resonance imaging, 22 patients (26% [95% CI, 17%-37%]) had at least 1 microbleed. After TAVR, new microbleeds were observed in 19 (23% [95% CI, 14%-33%]) patients. The occurrence of new microbleeds was independent of the presence of microbleeds at baseline and of diffusion-weighted imaging hypersignals. In univariable analysis, a previous history of bleeding ( P =0.01), a higher total dose of heparin ( P =0.02), a prolonged procedure ( P =0.03), absence of protamine reversion ( P =0.04), higher final activated partial thromboplastin time ( P =0.05), lower final von Willebrand factor high-molecular-weight:multimer ratio ( P =0.007), and lower final closure time with adenosine-diphosphate ( P =0.02) were associated with the occurrence of new postprocedural microbleeds. In multivariable analysis, a prolonged procedure (odds ratio, 1.22 [95% CI, 1.03-1.73] for every 5 minutes of fluoroscopy time; P =0.02) and postprocedural acquired von Willebrand factor defect (odds ratio, 1.42 [95% CI, 1.08-1.89] for every lower 0.1 unit of high-molecular-weight:multimer ratio; P =0.004) were independently associated with the occurrence of new postprocedural microbleeds. New CMBs were not associated with changes in neurologic functional outcome or quality of life at 6 months., Conclusions: One out of 4 patients undergoing TAVR has CMBs before the procedure and 1 out of 4 patients develops new CMBs. Procedural or antithrombotic management and persistence of acquired von Willebrand factor defect were associated with the occurrence of new CMBs., Registration: URL: https://www., Clinicaltrials: gov; Unique identifier: NCT02972008.
- Published
- 2022
- Full Text
- View/download PDF
7. Balloon aortic valvuloplasty for severe aortic stenosis before urgent non-cardiac surgery.
- Author
-
Debry N, Altes A, Vincent F, Delhaye C, Schurtz G, Nedjari F, Legros G, Porouchani S, Coisne A, Richardson M, Cosenza A, Verdier B, Denimal T, Pamart T, Spillemaeker H, Sylla H, Sudre A, Janah D, Aouate D, Marsou W, Appert L, Lemesle G, Labreuche J, Maréchaux S, and Van Belle E
- Subjects
- Aortic Valve diagnostic imaging, Aortic Valve surgery, Humans, Retrospective Studies, Risk Factors, Treatment Outcome, Aortic Valve Stenosis surgery, Balloon Valvuloplasty, Transcatheter Aortic Valve Replacement adverse effects
- Abstract
Background: Balloon aortic valvuloplasty (BAV) has been proposed as a therapeutic option in patients suffering from severe aortic stenosis (SAS) who need urgent non-cardiac surgery (NCS). Whether this strategy is better than medical therapy in this very specific population is unknown., Aims: We aimed to evaluate the clinical benefit of an invasive strategy (IS) with preoperative BAV in patients with SAS requiring urgent NCS., Methods: From 2011 to 2019, a registry conducted in two centres included 133 patients with SAS undergoing urgent NCS, of whom 93 underwent preoperative BAV (IS) and 40 a conservative strategy (CS) without BAV. All analyses were adjusted for confounding using inverse probability of treatment weighting (IPTW) (10 clinical and anatomical variables)., Results: The primary outcome was MACE at one-month follow-up after NCS including mortality, heart failure, and other cardiovascular outcomes. In patients managed conservatively, occurrence of MACE was 20.0% (n=8) and death was 10.0% (n=4) at 1 month. In patients undergoing BAV, the occurrence of MACE was 20.4% (n=19) and death was 5.4% (n=5) at 1 month. Among patients undergoing conservative management, all events were observed after NCS while, in patients undergoing BAV, 12.9% (n=12) had events between BAV and NCS including 3 deaths, and 7.5% (n=7) had events after NCS including 2 deaths. In IPTW propensity analyses, the incidence of the primary outcome (20.4% vs 20.0%; OR 0.93, 95% CI: 0.38-2.29) and three-month survival (89.2% vs 90.0%; IPTW-adjusted HR 0.90, 95% CI: 0.31-2.60) were similar in both groups., Conclusions: Patients with SAS managed conservatively before urgent NCS are at high risk of events. A systematic invasive strategy using BAV does not provide a significant improvement in clinical outcome.
- Published
- 2021
- Full Text
- View/download PDF
8. Feasibility and safety of transfemoral transcatheter aortic valve implantation performed with a percutaneous coronary intervention-like approach.
- Author
-
Denimal T, Delhaye C, Piérache A, Robin E, Modine T, Moussa M, Sudre A, Koussa M, Debry N, Pamart T, Lamblin N, Lemesle G, Spillemaeker H, Verdier B, Porouchani S, Cosenza A, Bical A, Schurtz G, Labreuche J, Ternacle J, Balmette V, Aouate D, Denis T, Janah D, Sylla H, Roy B, Desbordes J, Van Belle E, and Vincent F
- Subjects
- Aortic Valve diagnostic imaging, Aortic Valve surgery, Feasibility Studies, Fluoroscopy, Humans, Treatment Outcome, Aortic Valve Stenosis diagnostic imaging, Aortic Valve Stenosis surgery, Percutaneous Coronary Intervention adverse effects, Transcatheter Aortic Valve Replacement adverse effects
- Abstract
Background: Transfemoral percutaneous transcatheter aortic valve implantation (TF-TAVI) is a safe, reproducible and established procedure, mainly performed under local anaesthesia, which is mostly administered and monitored by a dedicated anaesthesia team (regular approach). Our centre has developed a standardized pathway of care, and eligible patients are selected for a minimalist TF-TAVI, entirely managed by operators without the presence of the anaesthesia team in the operating room, like most interventional coronary procedures ("percutaneous coronary intervention-like" approach [PCI approach])., Aim: To compare the safety and efficacy of TF-TAVI performed with the PCI approach versus the regular approach., Methods: The analysis population comprised all patients who underwent TF-TAVI with the PCI or regular approach in our institution from November 2016 to July 2019. The two co-primary endpoints were early safety composite and early efficacy composite at 30days as defined by the Valve Academic Research Consortium-2. The PCI (n=137) and Regular (n=221) approaches were compared using the propensity score based method of inverse probability of treatment weighting., Results: No differences were observed after comparison of TAVI performed with the PCI or regular approach regarding the composite safety endpoint (7.3% vs. 11.3%; odds ratio 0.63, 95% confidence interval 0.37 to 1.07; P=0.086) or the composite efficacy endpoint (4.4% vs. 6.3%; odds ratio 0.78, 95% confidence interval 0.41 to 1.49; P=0.45)., Conclusions: This study suggests that the efficacy and safety of TF-TAVI entirely managed by a PCI approach for selected patients are not different to those when TF-TAVI is performed with the attendance of a full anaesthesia care team. The PCI approach appears to be a safe and efficient clinical pathway, providing an appropriate and rational utilization of anaesthesiology resources, and could be used for the majority of TF-TAVI procedures., (Copyright © 2021 Elsevier Masson SAS. All rights reserved.)
- Published
- 2021
- Full Text
- View/download PDF
9. Transcatheter Aortic Valve Replacement in Bicuspid Aortic Valve Stenosis.
- Author
-
Vincent F, Ternacle J, Denimal T, Shen M, Redfors B, Delhaye C, Simonato M, Debry N, Verdier B, Shahim B, Pamart T, Spillemaeker H, Schurtz G, Pontana F, Thourani VH, Pibarot P, and Van Belle E
- Subjects
- Aged, Aged, 80 and over, Female, Humans, Male, Aortic Valve Stenosis surgery, Bicuspid Aortic Valve Disease surgery, Transcatheter Aortic Valve Replacement methods
- Abstract
After 15 years of successive randomized, controlled trials, indications for transcatheter aortic valve replacement (TAVR) are rapidly expanding. In the coming years, this procedure could become the first line treatment for patients with a symptomatic severe aortic stenosis and a tricuspid aortic valve anatomy. However, randomized, controlled trials have excluded bicuspid aortic valve (BAV), which is the most frequent congenital heart disease occurring in 1% to 2% of the total population and representing at least 25% of patients 80 years of age or older referred for aortic valve replacement. The use of a less invasive transcatheter therapy in this elderly population became rapidly attractive, and approximately 10% of patients currently undergoing TAVR have a BAV. The U.S. Food and Drug Administration and the "European Conformity" have approved TAVR for low-risk patients regardless of the aortic valve anatomy whereas international guidelines recommend surgical replacement in BAV populations. Given this progressive expansion of TAVR toward younger and lower-risk patients, heart teams are encountering BAV patients more frequently, while the ability of this therapy to treat such a challenging anatomy remains uncertain. This review will address the singularity of BAV anatomy and associated technical challenges for the TAVR procedure. We will examine and summarize available clinical evidence and highlight critical knowledge gaps regarding TAVR utilization in BAV patients. We will provide a comprehensive overview of the role of computed tomography scans in the diagnosis, and classification of BAV and TAVR procedure planning. Overall, we will offer an integrated framework for understanding the current role of TAVR in the treatment of bicuspid aortic stenosis and for guiding physicians in clinical decision-making.
- Published
- 2021
- Full Text
- View/download PDF
10. Myocardial Infarction incidence during national lockdown in two French provinces unevenly affected by COVID-19 outbreak: An observational study.
- Author
-
Van Belle E, Manigold T, Piérache A, Furber A, Debry N, Luycx-Bore A, Bauchart JJ, Nugue O, Huchet F, Bic M, Vinchon F, Sayah S, Fournier A, Decoulx E, Mouhammad U, Clerc J, Manchuelle A, Lazizi T, Chmait A, Jeannetteau J, Hénon P, Bonin M, Dupret-Minet M, Tirouvanziam A, Molcard D, Arabucki F, Py A, Prunier F, Delhaye C, Lemesle G, Schurtz G, Cosenza A, Spillemaeker H, Verdier B, Denimal T, Pamart T, Sylla H, Janah D, Aouate D, Porouchani S, Guillez V, Bonnet G, Ternacle J, Labreuche J, Cayla G, and Vincent F
- Abstract
Background: A reduction of admission for MI has been reported in most countries affected by COVID-19. No clear explanation has been provided., Methods: To report the incidence of myocardial infarction (MI) admission during COVID-19 pandemic and in particular during national lockdown in two unequally affected French provinces (10-million inhabitants) with a different media strategy, and to describe the magnitude of MI incidence changes relative to the incidence of COVID-19-related deaths. A longitudinal study to collect all MIs from January 1 until May 17, 2020 (study period) and from the identical time period in 2019 (control period) was conducted in all centers with PCI-facilities in northern "Hauts-de-France" province and western "Pays-de-la-Loire" Province. The incidence of COVID-19 fatalities was also collected., Findings: In "Hauts-de-France", during lockdown (March 18-May 10), 1500 COVID-19-related deaths were observed. A 23% decrease in MI-IR (IRR=0.77;95%CI:0.71-0.84, p <0.001) was observed for a loss of 272 MIs (95%CI:-363,-181), representing 18% of COVID-19-related deaths. In "Pays-de-la-Loire", 382 COVID-19-related deaths were observed. A 19% decrease in MI-IR (IRR=0.81; 95%CI=0.73-0.90, p <0.001) was observed for a loss of 138 MIs (95%CI:-210,-66), representing 36% of COVID-19-related deaths. While in "Hauts-de-France" the MI decline started before lockdown and recovered 3 weeks before its end, in "Pays-de-la-Loire", it started after lockdown and recovered only by its end. In-hospital mortality of MI patients was increased during lockdown in both provinces (5.0% vs 3.4%, p =0.02)., Interpretation: It highlights one of the potential collateral damages of COVID-19 outbreak on cardiovascular health with a dramatic reduction of MI incidence. It advocates for a careful and weighted communication strategy in pandemic crises., Funding: The study was conducted without external funding., Competing Interests: Dr. Lemesle reports personal fees from Amgen, Astra Zeneca, Bayer, Boehringer Ingelheim, BMS, Daiichi Sankyo, Lilly, MSD, Mylan, Novartis, Novonordisk, Pfizer, Sanofi Aventis, Servier, outside the submitted work. Dr Delhaye reports personal fees from Medtronic outside the submitted work. Dr. Cayla reports personal fees from Amgen, personal fees from Astra Zeneca, personal fees from Bayer, personal fees from Biotronik, personal fees from Bristol Myers Squibb, grants and personal fees from Medtronic, personal fees from MSD, personal fees from Pfizer, personal fees from Sanofi, outside the submitted work. The other authors do not report any conflict of interest., (© 2021 The Authors.)
- Published
- 2021
- Full Text
- View/download PDF
11. Ultrasound Guidance to Reduce Vascular and Bleeding Complications of Percutaneous Transfemoral Transcatheter Aortic Valve Replacement: A Propensity Score-Matched Comparison.
- Author
-
Vincent F, Spillemaeker H, Kyheng M, Belin-Vincent C, Delhaye C, Piérache A, Denimal T, Verdier B, Debry N, Moussa M, Schurtz G, Porouchani S, Cosenza A, Juthier F, Pamart T, Richardson M, Coisne A, Hertault A, Sobocinski J, Modine T, Pontana F, Duhamel A, Labreuche J, and Van Belle E
- Subjects
- Aged, Aged, 80 and over, Female, Femoral Artery injuries, Fluoroscopy, Humans, Male, Postoperative Hemorrhage etiology, Postoperative Hemorrhage mortality, Propensity Score, Punctures, Retrospective Studies, Risk Assessment, Risk Factors, Time Factors, Treatment Outcome, Vascular System Injuries etiology, Vascular System Injuries mortality, Catheterization, Peripheral adverse effects, Catheterization, Peripheral mortality, Femoral Artery diagnostic imaging, Postoperative Hemorrhage prevention & control, Radiography, Interventional adverse effects, Radiography, Interventional mortality, Transcatheter Aortic Valve Replacement adverse effects, Transcatheter Aortic Valve Replacement mortality, Ultrasonography, Interventional adverse effects, Ultrasonography, Interventional mortality, Vascular System Injuries prevention & control
- Abstract
Background Ultrasound (US) guidance provides the unique opportunity to control the puncture zone of the artery during transfemoral transcatheter aortic valve replacement and may decrease major vascular complications (VC) and life-threatening or major bleeding complications. This study aimed to evaluate the clinical impact of US guidance using a propensity score-matched comparison. Methods and Results US guidance was implemented as the default approach for all transfemoral transcatheter aortic valve replacement cases in our institution in June 2013. We defined 3 groups of consecutive patients according to the method of puncture (fluoroscopic/US guidance) and the use of a transcatheter heart valve. Patients in the US-guided second-generation group (Sapien XT [Edwards Lifesciences, Irvine, CA], Corevalve [Medtronic, Dublin, Ireland]) were successfully 1:1 matched with patients in the fluoroscope-guided second-generation group (n=95) with propensity score matching. In a second analysis we described the consecutive patients of the US-guided third-generation group (Evolut-R [Medtronic], Sapien 3 [Edwards Lifesciences], n=308). All vascular and bleeding complications were reduced in the US-guided second-generation group compared with the fluoroscope-guided second-generation group: VC (16.8% versus 6.3%; P =0.023); life-threatening or major bleeding (22.1% versus 6%; P =0.004); and VC related to vascular access (12.6% versus 4.2%; P =0.052). In the US-guided third-generation group the rates of major VC and life-threatening or major bleeding were 3.2% (95% CI, 1.6% to 5.9%) and 3.6% (95% CI, 1.8% to 6.3%). In the overall population (n=546), life-threatening or major bleeding was associated with a 1.7-fold increased mortality risk ( P =0.02). Conclusions We demonstrated that US guidance effectively reduced VC and bleeding complications for transfemoral transcatheter aortic valve replacement and should be considered the standard puncture method. Registration URL: http://www.clinicaltrials.gov. Unique identifier: NCT02628509.
- Published
- 2020
- Full Text
- View/download PDF
Catalog
Discovery Service for Jio Institute Digital Library
For full access to our library's resources, please sign in.