1. Thermoluminescence and ATR-FTIR study of UVC-irradiated low-density polyethylene (LDPE) food packaging.
- Author
-
Boronat C, Correcher V, Benavente JF, and Bravo-Yagüe JC
- Subjects
- Spectroscopy, Fourier Transform Infrared methods, Thermoluminescent Dosimetry methods, Polyethylene chemistry, Ultraviolet Rays, Food Packaging
- Abstract
This research aims to study the effects of ultraviolet C (UVC) radiation on low-density polyethylene (LDPE) food packaging. Main objectives include evaluating LDPE degradation and detecting UVC radiation using thermoluminescent dosimeters (TLDs) placed under LDPE samples. Results confirm accurate UVC detection after one hour of exposure, providing a useful tool for optimize food treatment procedures. ATR-FTIR spectroscopy analysis revealed subtle alterations (<8 % transmittance relative) in UVC-irradiated LDPE samples, including possible CH breakage (2910 and 2848 cm
-1 ) and potential CC bond vibrations (1470 cm-1 ), among others. However, observed variations may stem from LDPE properties rather than entirely from UVC radiation. A comparative study of UVC-induced thermoluminescence (TL) emissions provided insights into various TLDs materials. TL kinetic analysis, using computerised glow curve deconvolution (CGCD) method, unveiled trap charge activation due to UVC exposure, including partial ionization, bleaching effect and photo-transfer (PTTL) processes. LDPE samples amplified UVC-TL responses, revealing intensity differences between the TLDs attributed to the PTTL process, accentuated by the lack of an annealing treatment. Additionally, chemical composition of the TL detectors such as, type, concentration, number, oxidation states and ionic radii of their dopants may influence UVC-TL response. Consequently, TL intensity ratios follow as: GR-200 (LiF: Mg, Cu, P) > TLD-100 (LiF: Ti, Mg) > TLD-400 (CaF2 : Mn) > TLD-200 (CaF2 : Dy). Thus, GR-200 detects ionizing radiation but cannot distinguish between ionizing and non-ionizing UVC radiation, while TLD-100 has limited effectiveness as a UVC radiation detector. In contrast, TLD-400 is suitable for detecting UVC radiation and TLD-200 emerges as the most favorable UVC detector, showing consistent response levels and minimal PTTL effect placed under the LDPE samples without the need of a thermal annealing treatment that makes the TLD-200 to be reusable in a low-cost measurement protocol., Competing Interests: Declaration of competing interest The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper., (Copyright © 2024 The Author(s). Published by Elsevier B.V. All rights reserved.)- Published
- 2024
- Full Text
- View/download PDF