120 results on '"Tornillos Óseos"'
Search Results
2. Evaluación de la placa ósea mandibular en pacientes con diferente patrón de crecimiento vertical
- Author
-
Luis Angel García-Gonzales and Vilma Ruiz
- Subjects
Cone-beam computed tomography ,Orthodontic anchorage procedures ,Bone screws ,Maxillofacial development ,Mandible ,Molar (MeSH) ,Mandíbula ,Diente molar (DeCS) ,Building and Construction ,Desarrollo maxilofacial ,Molar ,Tomografía computarizada de haz cónico ,Métodos de anclaje en ortodoncia ,Tornillos óseos ,Electrical and Electronic Engineering - Abstract
The purpose of this research was the tomographic evaluation of the Mandibular Buccal Shelf (MBS) in orthodontic patients with different vertical growth pattern. An observational, descriptive, cross-sectional and retrospective study was conducted. Tomographic images of patients aged 14 to 40 years were observed and a database was formed with those that met the inclusion criteria. The sample size was 10 for each group according to vertical growth pattern (hypodivergent, normodivergent and hyperdivergent). Then four zones of frequent insertion of extralveolar mini-screws were selected in the MBS, taking as a reference the mesial and distal roots of the first and second mandibular molar. When comparing the characteristics of MBS between vertical growth patterns, between sexes and hemiarchs, no statistically significant differences were found. However, when the characteristics of MBS were compared according to the reference root, it was found that there were statistically significant differences. The vestibular area to the distal root of the second mandibular molar presented the highest values in terms of angulation, height and thickness. There are no significant differences in the bone characteristics of MBS according to vertical growth patterns, sexes or hemiarchs. Angulation, height and thickness progressively increase from the vestibular bone of the mesial root of the first mandibular molar to the distal root of the second molar. Resumen El propósito de esta investigación fue la evaluación tomográfica de la placa ósea mandibular (POM) en pacientes de ortodoncia con diferente patrón de crecimiento vertical. Se realizó un estudio de tipo observacional, descriptivo, transversal y retrospectivo. Se observó imágenes tomográficas de pacientes de 14 a 40 años de edad y se formó una base de datos con las que cumplían los criterios de selección. El tamaño de muestra fue de 10 para cada grupo según patrón de crecimiento vertical (hipodivergentes, normodivergentes e hiperdivergentes). Luego se seleccionaron cuatro zonas de inserción frecuente de minitornillos extralveolares en la POM, tomando como referencia las raíces mesial y distal del primer y segundo molar mandibular. Al realizar la comparación de las características de la POM entre patrones de crecimiento vertical, entre sexos y hemiarcadas no se encontraron diferencias estadísticamente significativas. Sin embargo, cuando se comparó las características de la POM según la raíz de referencia se encontró que había diferencias estadísticamente significativas. La zona vestibular a la raíz distal de la segunda molar mandibular presento los mayores valores en cuanto angulación, altura y grosor. No existen diferencias significativas en las características óseas de la POM según patrones de crecimiento vertical, sexos o hemiarcadas. La angulación, la altura y el grosor aumenta progresivamente desde el hueso vestibular de la raíz mesial del primer molar mandibular hacia la raíz distal del segundo molar.
- Published
- 2023
- Full Text
- View/download PDF
3. Biofilme em parafusos ortopédicos prontos para uso adquiridos por meio de sistema de consiganação/comodato
- Author
-
Luiz Antônio Pereira, Lillian Kelly de Oliveira Lopes, Dayane de Melo Costa, Michelle Augusta dos Santos, Isabella Marra de Queiroz Boff, Lara Stefânia Netto de Oliveira Leão-Vasconcelos, Karen Vickery, and Anaclara Ferreira Veiga Tipple
- Subjects
Advanced and Specialized Nursing ,Anti-infecciosos ,Procedimientos ortopédicos ,Bacteria ,Parafusos ósseos ,Sterilization ,Orthopedic procedures ,Procedimentos ortopédicos ,Prótesis e implantes ,Esterilização ,Medical–Surgical Nursing ,Esterilización ,Biopelículas ,Prostheses and implants ,Biofilms ,Anti-infective agents ,Tornillos óseos ,Próteses e implantes ,Antiinfecciosos ,Bacterias ,Bone screws ,Biofilmes - Abstract
Resumo Objetivo Avaliar a integridade da superfície e as condições microbiológicas de parafusos prontos para uso em bandejas ortopédicas após múltiplos processamentos. Métodos Após o processamento completo, as bandejas utilizadas em cirurgias de pequenos fragmentos, fornecidas por meio de sistema de consignação/comodato em um hospital brasileiro, foram selecionadas aleatoriamente durante quatro meses. Os parafusos mais utilizados (números 14, 16 e 18 – Grupo 1) e menos utilizados (números 10 e 38 – Grupo 2), portanto, os mais e menos expostos a agentes biológicos, químicos e físicos, foram aleatoriamente removidos e submetidos a inspeção visual (n=126), seguido de cultura bacteriana (n=6 parafusos/bandeja, 9 bandejas), teste de proteínas (n=6 parafusos/bandeja, 9 bandejas) e Microscopia Eletrônica de Varredura (MEV) (n=2 parafusos/bandeja, 9 bandejas). As culturas positivas foram submetidas a métodos automatizados de identificação bacteriana e suscetibilidade antimicrobiana. Resultados Foram detectadas ranhuras em 8,7% dos parafusos, predominantemente no Grupo 2 (8/11). Proteína residual foi detectada em 96,3%, e não houve diferença estatisticamente significativa na quantidade de proteína entre os grupos (P=0,07). Crescimento bacteriano foi identificado em 3/54 parafusos. Danos na superfície e presença de sujidade foram visualizados em todos os parafusos submetidos a MEV. Formação de biofilmes extensos foi detectada em oito parafusos, três do Grupo 1 e cinco do Grupo 2. Conclusão Recuperação de bactérias viáveis, acúmulo de biofilme e danos na superfície foram detectados nos parafusos prontos para uso. Os parafusos costumam permanecer nas bandejas cirúrgicas e serem submetidos a múltiplos processamento, sendo expostos a contaminação e danos repetidas vezes. Esses achados apontam para a necessidade de discutir e repensar a forma como esses implantes de uso único são atualmente disponibilizados para cirurgias. Resumen Objetivo Evaluar la integridad de la superficie y las condiciones microbiológicas de tornillos listos para uso en bandejas ortopédicas después de múltiples procesamientos. Métodos Después del procesamiento completo, fueron seleccionadas aleatoriamente durante cuatro meses las bandejas utilizadas en cirugías de pequeños fragmentos, proporcionadas mediante el sistema de consignación/comodato en un hospital brasileño. Los tornillos más utilizados (números 14, 16 y 18 – Grupo 1) y menos utilizados (números 10 y 38 – Grupo 2), por lo tanto, los más y menos expuestos a agentes biológicos, químicos y físicos, fueron quitados aleatoriamente y sometidos a inspección visual (n=126), seguido de cultivo bacteriano (n=6 tornillos/bandeja, 9 bandejas), prueba de proteínas (n=6 tornillos/bandeja, 9 bandejas) y microscopía electrónica de barrido (MEB) (n=2 tornillos/bandeja, 9 bandejas). Los cultivos positivos fueron sometidos a métodos automatizados de identificación bacteriana y susceptibilidad antimicrobiana. Resultados Se detectaron ranuras en el 8,7 % de los tornillos, predominantemente en el Grupo 2 (8/11). Se detectó proteína residual en el 96,3 % y no se encontró diferencia estadísticamente significativa en la cantidad de proteína entre los grupos (P=0,07). En 3/54 tornillos se identificó crecimiento bacteriano. Se visualizaron daños en la superficie y presencia de suciedad en todos los tornillos sometidos a MEB. En ocho tornillos se detectó la formación de biopelículas, tres del Grupo 1 y cinco del Grupo 2. Conclusión Se detectó recuperación de bacterias viables, acumulación de biopelícula y daños en la superficie en los tornillos listos para uso. Los tornillos suelen permanecer en las bandejas quirúrgicas y son sometidos a múltiples procesamientos, donde están expuestos a contaminación y daños repetidas veces. Estos descubrimientos señalan la necesidad de discutir y repensar la forma como estos implantes de uso único se ponen a disposición para cirugía actualmente. Abstract Objective Assess the surface integrity and microbiological conditions of patient-ready screws in orthopaedic trays that had been multiply reprocessed. Methods After full reprocessing, clinical trays used for small fragment surgery provided through a loaner system to a Brazilian hospital were randomly selected during four months. The most (numbers 14, 16 and 18 – Group 1) and least (numbers 10 and 38 – Group 2) frequently implanted screws, therefore, the ones estimated to be the most and least exposed to biological, chemical and physical agents, were randomly removed and subjected to visual inspection (n=126), followed by bacterial culture (n=6 screws/tray, 9 trays), protein test (n=6 screws/tray, 9 trays) and Scanning Electron Microscopy (SEM) (n=2 screws/tray, 9 trays). Positive cultures were subjected to automated bacterial identification and antimicrobial susceptibility tests. Results Grooves were detected on 8.7% screws, predominantly in Group 2 (8/11). Residual protein was detected on 96,3%, and there was no statistically significant difference in the amount of protein between the groups (P=0.07). Bacterial growth was identified in 3/54 screws. Surface damage and soil were visualized on all screws subjected to SEM. Extensive biofilms were detected on eight screws, three from Group 1 and five from Group 2. Conclusion Recovery of bacteria, biofilm accumulation and surface damage were detected on patient-ready screws. Screws frequently remain in surgical trays for multiple reprocessing; thus they are repeatedly exposed to contamination and damage. These findings point to the need to discuss and review the way these single-use implants are currently made available for surgeries.
- Published
- 2023
4. Manejo de segundos molares permanentes retenidos. Revisión de la literatura
- Author
-
Jaramillo Nivicela, Nicole Andrea and Palacios Vivar, Diego Esteban
- Subjects
DIENTE ERUPCIONADO ,TORNILLOS OSEOS ,SEGUNDO MOLAR MANDIBULAR ,DIENTE MOLAR - Abstract
Objetivo: Realizar una revisión de la literatura acerca de los tratamientos ortodóncicos y quirúrgicos de los segundos molares permanentes retenidos. Métodos: Se realizó un estudio de tipo descriptivo, retrospectivo, de la literatura, para lo cual se consultaron bases de datos electrónicas como Pubmed, Scopus, Web of Science, Taylor & Francis, Springer Link, Scielo; los estudios afines al tema fueron identificados mediante el empleo de descriptores en ciencias de la salud (DeCs), términos MeSH y operadores booleanos. Resultados: El manejo de segundos molares retenidos depende de su impactación. Para impactaciones profundas existen métodos quirúrgicos ortodóncicos como el uso de minitornillos con cadena elástica en la zona retromolar y rama anterior de la mandíbula. Para segundos molares levemente inclinados existe un método de exposición quirúrgica como la operculectomía. Para los segundos molares donde no es posible un tratamiento quirúrgico y ortodóncico se recomienda la extracción. Conclusión: El tratamiento de los segundos molares permanentes retenidos va a depender de la situación clínica y radiográfica, así como la experiencia del equipo formado entre el ortodoncista y el cirujano Trabajo de investigación
- Published
- 2023
5. Open Reduction and Internal Fixation of a Fracture-dislocation of the Ankle
- Author
-
Yaniel Truffin Rodriguez, José Julio Requeiro Molina, and Gerardo Águila Tejeda
- Subjects
fracturas del tobillo ,traumatismos del tobillo ,fijación interna de fracturas ,hilos ortopédicos ,tornillos óseos ,Medicine (General) ,R5-920 ,Public aspects of medicine ,RA1-1270 - Abstract
Open reduction and internal fixation of the fracture-dislocation of the ankle with plates, screws and Kirschner wires is a well-defined treatment method. This paper presents the management of a fracture-dislocation of the right ankle in a 33-year-old female patient stabilized by using a one-third tubular plate, screws, and Kirschner wires with tension-band wires. Results were satisfactory.
- Published
- 2015
6. ONE OR TWO SCREWS IN THE FRACTURE OF THE ODONTOID PROCESS? EVALUATION USING COMPUTED TOMOGRAPHY
- Author
-
Carlos Alexandre Botelho do Amaral, Edgar Taira Nakagawa, Leonardo Ternis Ferreira, José Sergio Franco, Robinson Esteves Santos Pires, Flávio Cavallari, and Pedro José Labronici
- Subjects
Apófisis odontoides ,Tomografía computarizada por rayos X ,Tornillos óseos ,Columna vertebral ,Orthopedic surgery ,RD701-811 ,Diseases of the musculoskeletal system ,RC925-935 - Abstract
Objective:To evaluate the bone area of the odontoid process through computed tomography and its relation with the area of one and two screws in the male and female subjects.Methods:188 CT scans of adults were analyzed. The isthmus area was selected and the transverse diameter was measured at 1.2 mm from the base of odontoid.Results:After placement of a screw, the odontoid area remains with 82% of free bone for both men and women. With two screws, 45.6% of women, had a free bone area of the odontoid process between 50% and 75% and 54.4% were above 75%. 26.6% men had percentage from 50% to 75% of free bone area and 73.4% above 75% (p=0.07). After the placement of two screws, the bone area was, in average, 77.3% in men and 75.4% in women. Using the Student t-test, the differences between the average of percentage of free bone area in men and women are significantly lower in women (p=0.0012).Conclusion:The pre-operative planning through CT can help to choose the number of screws in the odontoid process. The choice should be particularly careful when using two screws in women.
- Published
- 2015
- Full Text
- View/download PDF
7. Positioning of pedicle screws in adolescent idiopathic scoliosis using electromyography
- Author
-
Bruno Moreira Gavassi, Raphael de Rezende Pratali, Carlos Eduardo Gonçales Barsotti, Ricardo José Rodriguez Ferreira, Francisco Prado Eugenio dos Santos, and Carlos Eduardo Algaves Soares de Oliveira
- Subjects
Escoliosis ,Tornillos óseos ,Monitorización neurofisiológica intraoperatoria ,Tomografía computarizada por rayos X ,Orthopedic surgery ,RD701-811 ,Diseases of the musculoskeletal system ,RC925-935 - Abstract
OBJECTIVE: To analyze the occurrence of poor positioning of pedicle screws inserted with the aid of intraoperative electromyographic stimulation in the treatment of Adolescent Idiopathic Scoliosis (AIS).METHODS: This is a prospective observational study including all patients undergoing surgical treatment for AIS, between March and December 2013 at a single institution. All procedures were monitored by electromyography of the inserted pedicle screws. The position of the screws was evaluated by assessment of postoperative CT and classified according to the specific AIS classification system.RESULTS: Sixteen patients were included in the study, totalizing 281 instrumented pedicles (17.5 per patient). No patient had any neurological deficit or complaint after surgery. In the axial plane, 195 screws were found in ideal position (69.4%) while in the sagittal plane, 226 screws were found in ideal position (80.4%). Considering both the axial and the sagittal planes, it was observed that 59.1% (166/281) of the screws did not violate any cortical wall.CONCLUSION: The use of pedicle screws proved to be a safe technique without causing neurological damage in AIS surgeries, even with the occurrence of poor positioning of some implants.
- Published
- 2015
- Full Text
- View/download PDF
8. Percutaneous fusion of lumbar facet with bone allograft
- Author
-
Félix Dolorit Verdecia and Hiram Martinez Medina
- Subjects
Fusión vertebral ,Vértebras lumbares ,Tornillos óseos ,Orthopedic surgery ,RD701-811 ,Diseases of the musculoskeletal system ,RC925-935 - Abstract
OBJECTIVE: To assess the evolution of the cases treated with percutaneous facet fusion with bone allograft in lumbar facet disease. METHOD: Between 2010 and 2014, 100 patients (59 women and 41 men) diagnosed with lumbar facet disease underwent surgery. RESULTS: The lumbar facet fusion with bone allograft shows good clinical results, is performed on an outpatient basis, and presents minimal complications and rapid incorporation of the patient to the activities of daily living. CONCLUSIONS: The lumbar facet fusion with bone allograft appears to be an effective treatment for lumbar facet disease.
- Published
- 2015
- Full Text
- View/download PDF
9. Tomographic Evaluation of Mandibular Buccal Shelf in Patients with Different Vertical Growth Pattern
- Author
-
García Gonzales, Luis Angel, Ruiz García de Chacón, Vilma, García Gonzales, Luis Angel, and Ruiz García de Chacón, Vilma
- Abstract
The purpose of this research was the tomographic evaluation of the Mandibular Buccal Shelf (MBS) in orthodontic patients with different vertical growth pattern. An observational, descriptive, cross-sectional and retrospective study was conducted. Tomographic images of patients aged 14 to 40 years were observed and a database was formed with those that met the inclusion criteria. The sample size was 10 for each group according to vertical growth pattern (hypodivergent, normodivergent and hyperdivergent). Then four zones of frequent insertion of extralveolar mini-screws were selected in the MBS, taking as a reference the mesial and distal roots of the first and second mandibular molar. When comparing the characteristics of MBS between vertical growth patterns, between sexes and hemiarchs, no statistically significant differences were found. However, when the characteristics of MBS were compared according to the reference root, it was found that there were statistically significant differences. The vestibular area to the distal root of the second mandibular molar presented the highest values in terms of angulation, height and thickness. There are no significant differences in the bone characteristics of MBS according to vertical growth patterns, sexes or hemiarchs. Angulation, height and thickness progressively increase from the vestibular bone of the mesial root of the first mandibular molar to the distal root of the second molar., El propósito de esta investigación fue la evaluación tomográfica de la placa ósea mandibular (POM) en pacientes de ortodoncia con diferente patrón de crecimiento vertical. Se realizó un estudio de tipo observacional, descriptivo, transversal y retrospectivo. Se observó imágenes tomográficas de pacientes de 14 a 40 años de edad y se formó una base de datos con las que cumplían los criterios de selección. El tamaño de muestra fue de 10 para cada grupo según patrón de crecimiento vertical (hipodivergentes, normodivergentes e hiperdivergentes). Luego se seleccionaron cuatro zonas de inserción frecuente de minitornillos extralveolares en la POM, tomando como referencia las raíces mesial y distal del primer y segundo molar mandibular. Al realizar la comparación de las características de la POM entre patrones de crecimiento vertical, entre sexos y hemiarcadas no se encontraron diferencias estadísticamente significativas. Sin embargo, cuando se comparó las características de la POM según la raíz de referencia se encontró que había diferencias estadísticamente significativas. La zona vestibular a la raíz distal de la segunda molar mandibular presento los mayores valores en cuanto angulación, altura y grosor. No existen diferencias significativas en las características óseas de la POM según patrones de crecimiento vertical, sexos o hemiarcadas. La angulación, la altura y el grosor aumenta progresivamente desde el hueso vestibular de la raíz mesial del primer molar mandibular hacia la raíz distal del segundo molar.
- Published
- 2022
10. Idiopathic scoliosis: evaluation of loss of correction in postoperative follow-up
- Author
-
Liliane Faria Garcia, Rodrigo Perroni Cruzeiro, Sávio Loureiro Laborne de Mendonça, Enguer Beraldo Garcia, Roberto Garcia Gonçalves, Sebastião Vasconcelos de Souza, and Enguer Beraldo Garcia Júnior
- Subjects
Escoliosis ,Procedimientos quirúrgicos operativos ,Tornillos óseos ,Orthopedic surgery ,RD701-811 ,Diseases of the musculoskeletal system ,RC925-935 - Abstract
OBJECTIVE: To evaluate the postoperative loss of scoliosis correction using third-generation instrumental, comparing the immediately postoperative period, and the last visit of the patients operated on from 2002 to 2010. METHOD: This was a cross-sectional study, conducted by analysis of medical records, in which 45 patients undergoing scoliosis correction were included. Variables were evaluated preoperatively, immediately postoperatively and in the last follow-up visit after surgery. Statistical analysis of data was performed in PASW program, with a significance level of 95%. RESULTS: Among the 45 patients studied, 88.9% were female and 82.8% were in the skeletally immature group. The mean pre-operative Cobb was 57°, the postoperative was 6.5° and at the last visit, it was 7.04°. There was no statistic difference between postoperative Cobb angle and that at the last examination (p = 0.176). CONCLUSION: There was no significant loss of scoliosis correction loss between the immediate postoperative and the final radiographic evaluation.
- Published
- 2014
- Full Text
- View/download PDF
11. Sagittal curve and high metal density in adolescent idiopathic scoliosis
- Author
-
Fabio Araújo Fernandes, João Paulo Machado Bergamaschi, Luciano Antonio Nassar Pellegrino, Ricardo Shigueaki Galhego Umeta, Maria Fernanda Silber Caffaro, Robert Meves, and Osmar Avanzi
- Subjects
Columna vertebral ,Cifosis ,Procedimientos quirúrgicos operativos ,Tornillos óseos ,Orthopedic surgery ,RD701-811 ,Diseases of the musculoskeletal system ,RC925-935 - Abstract
Objectives: To analyze radiographically the postoperative kyphosis from patients undergoing surgical treatment for AIS with pedicle screws in all vertebrae included in the arthrodesis. Methods: Retrospective study. The following measurements were evaluated: Cobb angle in anteroposterior radiograph of the three curves (proximal thoracic, main thoracic, and lumbar), Cobb angle in the lateral view of the two curves: thoracic kyphosis (T5-T12) and lumbar lordosis (T12-S1). Results: Of the 25 patients evaluated preoperatively, four (16%) were hypokyphotic, 20 patients (80%) were normokyphotic and only one (4%) was hyperkyphotic. For hypokyphotic and hiperkyphotic patients a satisfactory correction of thoracic kyphosis was obtained in 100% of cases, which was preserved in the final result. The same pattern of thoracic kyphosis was observed for all normokyphotic patients throughout the follow-up. Conclusion: Radiographic evaluation of thoracic kyphosis in patients with AIS treated surgically with pedicle screws in all vertebrae showed satisfactory results with respect to the correction of thoracic kyphosis.
- Published
- 2014
- Full Text
- View/download PDF
12. Mal posición de tornillos pediculares lumbares que producen radiculalgia mecánica postoperatoria con estimulación neurofisiológica intraoperatoria normal: el valor de la estimulación neurofisiológica del trayecto del tornillo
- Author
-
Vicente García González, Jesús Burgos Flores, Teresa Del Olmo, Carlos Barrios Pitarque, Eduardo Hevia Sierra, Luis Miguel Antón Rodrigálvarez, and Gema De Blas Beorlegui
- Subjects
Radiculopatía ,Columna vertebral ,Tornillos óseos ,Orthopedic surgery ,RD701-811 ,Diseases of the musculoskeletal system ,RC925-935 - Abstract
OBJETIVO: Valorar una exploración neurofisiológica que identifique estos casos intraoperatoriamente y evite la mal posición de tornillos pediculares. MÉTODOS: En 293 pacientes intervenidos de escoliosis por vía posterior con tornillos pediculares y técnica "free hand", se implantaron 6.739 tornillos. De estos, ocho pacientes (2,7%), con edad promedio de 24 años, presentaron dolor radicular lumbar postoperatorio. En la TC postoperatoria se encontraron 10 tornillos lumbares (2L1-3L2-4L3-1L4) con prominencia mínima en la parte inferior del pedículo. Se evaluaron los umbrales de EMG del tornillo y del trayecto. RESULTADOS: En cirugía inicial no se detectaron anomalías en la palpación del trayecto, ni en el control radioscópico, ni alteraciones neurofisiológicas en la estimulación neurofisiológica con t-EMG. Todos presentaron dolor radicular en bipedestación y sedestación que remitía con reposo en cama. Los tornillos fueron retirados quirúrgicamente a los 37 días en promedio (R:4-182). En esta cirugía se repitió la monitorización neurofisiológica y volvió a mostrar valores normales (> 11mA). Tras la retirada de los tornillos, se realizó estimulación del trayecto que mostró en la parte media, umbrales por debajo de los valores normales (3,9-10,7mA). Tras un seguimiento promedio de 4,4 años (R:2,6-6.8), cinco pacientes referían tener molestias radiculares ocasionales y uno tenía déficit motor mínimo en la extremidad afectada. CONCLUSIONES: Se presenta un tipo de mal posicionamiento de tornillo pedicular lumbar que produce radiculalgia en bipedestación-sedestación y que no es detectado con monitorización convencional. La estimulación neurofisiológica del trayecto en la zona media, tras retirada del tornillo pedicular, produjo umbrales bajos de estimulación. Se recomienda estimulación sistemática del trayecto antes de la inserción del tornillo pedicular lumbar.
- Published
- 2013
- Full Text
- View/download PDF
13. Resultado a largo plazo de las fusiones largas espinopelvicas en escoliosis: importancia de la edad, la capacidad de marcha y el tipo de fijación ilíaca
- Author
-
Carlos Eduardo De la Cabada, Jesús Burgos, Carlos Barrios, Pablo Vera, Eduardo Hevia, Ignacio Sanpera, Gabriel Pizá, Pedro Domenech, Luís Miguel Anton, Vicente Garcia, and Pedro Cortes
- Subjects
Escoliosis ,Fusión vertebral ,Tornillos óseos ,Resultado del tratamiento ,Orthopedic surgery ,RD701-811 ,Diseases of the musculoskeletal system ,RC925-935 - Abstract
OBJETIVO: Conocer los factores que influyen en los fracasos instrumentales lumbosacros después de fusiones espinopélvicas largas. MÉTODO: Estudio retrospectivo de pacientes diagnosticados con escoliosis, tratados quirúrgicamente por vía posterior, realizándo se fusión espinopélvica de T2 o T3 a ilíaco, utilizando tornillos pediculares e ilíacos. Se analizaron los fracasos instrumentales y su asociación con diferentes parámetros clínicos y radiológicos. RESULTADOS: Se presentan 44 pacientes con edad promedio de 24 años, con diferentes etiologías. El valor promedio preoperatorio de la curva mayor era de 74,2º, y en la revisión final la corrección promedio fue 67%. El desequilibrio anteroposterior y la inclinación pélvica, la cifosis torácica, la lordosis lumbar y el desequilibrio lateral mejoraron significativamente en la revisión final. Hubo 41% de fracasos de instrumentación, todos a nivel lumbosacro. Se encontró asociación significativa con más fracasos instrumentales en mayores de 17 años y en los que tenían deambulación autónoma. En 24 pacientes, se utilizó un solo tornillo ilíaco bilateralmente y en 20 pacientes, dos o más. Los dos grupos tuvieron una incidencia similar de fracasos. En el grupo de dos o más tornillos solo existieron roturas de barras sin desanclajes, ni lisis. El uso de implantes intersomáticos de L3 a S1 o cerclajes sublaminares con una tercera barra disminuyó la incidencia de fracasos. CONCLUSIONES: En esta serie se presentaron un 41% de fracasos instrumentales, todos localizados a nivel lumbosacro. Los pacientes con capacidad de deambulación autónoma y mayores de 17 años presentaron significativamente más fallas instrumentales. En los que se realizó fusión intersomática L3-S1 o una tercera barra con cerclajes sublaminares, disminuyó la incidencia.
- Published
- 2013
- Full Text
- View/download PDF
14. Resultados postoperatorios inmediatos y a largo plazo de un abordaje mini-invasivo para la corrección de escoliosis idiopática del adolescente
- Author
-
Helena Gómez, Jesús Burgos, Eduardo Hevia, José Ignacio Maruenda, Carlos Barrios, and Ignacio Sanpera
- Subjects
Escoliosis ,Adolescente ,Columna vertebral ,Tornillos óseos ,Procedimientos quirúrgicos mínimamente invasivos ,Orthopedic surgery ,RD701-811 ,Diseases of the musculoskeletal system ,RC925-935 - Abstract
OBJETIVO: Analizar los resultados de una nueva técnica quirúrgica mínimamente invasiva (MIS, por el inglés "minimally invasive surgery") por vía posterior aislada para la corrección quirúrgica de la escoliosis idiopática del adolescente (EIA). MÉTODOS: Se comparan dos grupos de pacientes con EIA tipo 1A de Lenke, similares en cuanto a edad, género, ángulo de Cobb, ápex de la curva, rotación vertebral, cifosis torácica, niveles de fusión, tipo de instrumentación y seguimiento. El Grupo 1 fue tratado con la técnica mínimamente invasiva que describiremos y el Grupo 2, de forma convencional. Se analizaron el tiempo quirúrgico, la pérdida sanguínea intraoperatoria, los requerimientos analgésicos en el postoperatorio inmediato, la estancia hospitalaria, la tasa de mal posición de los tornillos, la pérdida de corrección, la tasa de pseudoartrosis y la movilización de implantes. RESULTADOS: En el Grupo 1 (MIS) la cirugía disminuyó significativamente el sangrado y presentó menor número de casos de tornillos mal posicionados en la concavidad que el grupo tratado de forma convencional; sin embargo la cirugía tuvo mayor duración. Ambos grupos tuvieron requerimientos analgésicos similares y la estancia hospitalaria no presentó diferencias. A largo plazo en ninguno de los dos grupos se encontraron casos de no-unión, pérdidas de corrección, ni movilización de los implantes. CONCLUSIONES: La técnica MIS demostró prolongación del tiempo quirúrgico y menores pérdidas hemáticas, sin disminuir los requerimientos analgésicos ni la estancia hospitalaria. La corrección inicial de la escoliosis por la convexidad disminuyó la incidencia de tornillos mal posicionados en la concavidad, no dio lugar a pérdidas de corrección, movilización de implantes y no-unión.
- Published
- 2013
- Full Text
- View/download PDF
15. Influência do macheamento do orifício piloto nos parafusos cervicais anteriores Influencia del taladramiento del agujero piloto en tornillos cervicales anteriores Influence of tapping the pilot hole in anterior cervical screws
- Author
-
Patrícia Silva, João Paulo Chieregato Matheus, Rodrigo César Rosa, Maximiliano Aguiar Porto, Francisco José Albuquerque de Paula, Antonio Carlos Shimano, and Helton Luiz Aparecido Defino
- Subjects
Fijación de fractura ,Columna vertebral ,Tornillos óseos ,Histología ,Taladramiento ,Fixação de fratura ,Coluna vertebral ,Parafusos ósseos ,Histologia ,Macheamento ,Fracture fixation ,Spine ,Bone screws ,Histology ,Tapping ,Orthopedic surgery ,RD701-811 ,Diseases of the musculoskeletal system ,RC925-935 - Abstract
OBJETIVO: Analisar experimentalmente a influência do macheamento do orifício piloto nas propriedades mecânicas e na interface osso-implante do parafuso cervical anterior. MÉTODOS: Oito carneiros da raça Santa Inês deslanados foram utilizados no estudo. Nos segmentos vertebrais cervicais de C2-C7 foram realizados orifícios piloto de 2,5mm, de ambos os lados da vértebra. No lado direto da vértebra foi realizado o macheamento previamente a inserção do parafuso cortical de 3,5mm, e no lado esquerdo o implante foi colocado sem o macheamento do orifício piloto. Foram realizados ensaios mecânicos para avaliar a força de arrancamento dos implantes e estudo histomorfométrico da interface osso-implante na fase aguda e oito semanas após a colocação dos implantes. O torque de inserção foi mensurado durante a colocação dos implantes. RESULTADOS: O torque de inserção e a resistência ao arrancamento dos implantes foram maiores nos implantes colocados sem o macheamento do orifício piloto. A interface osso-implante apresentou maior área de contato ósseo e maior área óssea no interior da rosca do implante nos parafusos implantados sem o macheamento prévio. Não foi observado diferença na área óssea fora do passo de rosca do implante. CONCLUSÕES: O macheamento do orifício piloto reduz o torque de inserção e a resistência ao arrancamento do implante na fase aguda e crônica, e reduz a área de contato osso-implante e área de osso no interior do passo de rosca.OBJETIVO: Para estudiar experimentalmente la influencia del taladramiento del agujero piloto sobre las propiedades mecánicas y la interfaz hueso-implante del tornillo cervical anterior. MÉTODOS: Ocho ovejas Santa Ines fueron utilizadas en el estudio. En los segmentos vertebrales cervicales C2-C7 se hicieron agujeros pilotos de 2,5 mm en ambos lados de la vértebra. En el lado derecho de la vértebra el taladramiento se hizo antes de la inserción del tornillo cortical de 3,5 mm, y en el lado izquierdo el implante fue colocado sin el taladramiento del agujero piloto. Se realizaron ensayos mecánicos para evaluar la fuerza de retirada y el estudio histomorfométrico de la interfase hueso-implante en la fase aguda y ocho semanas después de la colocación del implante. El torque de inserción se midió durante la colocación del implante. RESULTADOS: La fuerza de torsión de la inserción y la resistencia a la extracción fueron más altas en los implantes colocados sin el taladramiento del agujero piloto. La interfaz hueso-implante presentó mayor área de contacto con el hueso y mayor área de hueso dentro de la rosca del implante en los tornillos implantados sin taladramiento previo. No se observaron diferencias en el hueso fuera del paso de la rosca del implante. CONCLUSIONES: El taladramiento del agujero piloto reduce el par de torsión de inserción y la resistencia a la extracción del implante en las fases aguda y crónica, y reduce el área de contacto hueso-implante y el área ósea en el interior del paso de la rosca.OBJECTIVE: Experimentally analyze the influence of the pilot hole tapping on the mechanical properties and the bone-implant interface of anterior cervical screw. METHODS: Eight shorn Santa Inês sheep were used in the study. In cervical segments C2-C7 of the column 2.5mm pilot holes were made on both sides of the vertebra. On the right side of the vertebra tapping was done before the insertion of the cortical screw of 3.5mm, and on the left side the implant was placed without tapping the pilot hole. Mechanical assays were performed to assess the strength of pullout as well as a histomorphometric study of bone-implant interface during the acute phase and eight weeks after implant placement. The insertion torque was measured during implant placement. RESULTS: The insertion torque and pullout strength were higher for implants placed without tapping the pilot hole. The bone-implant interface showed greater area of bone contact and greater bone area within the implant thread on the screws implanted without prior tapping. No differences were observed in the bone outside the thread pitch of the implant. CONCLUSIONS: Tapping the pilot hole reduces insertion torque and pullout strength of the implant in both acute and chronic phases, and reduces the area of bone-implant contact and the bone area within the thread pitch.
- Published
- 2013
16. Artrodesis circunferencial: Plif más tornillos translaminofacetarios
- Author
-
Javier Ricardo Méndez, Nicolás Federico Maldonado, and Enrique Gonzalo Bovier
- Subjects
Fusión vertebral ,Artrodesis ,Tornillos óseos ,Vértebras lumbares ,Orthopedic surgery ,RD701-811 ,Diseases of the musculoskeletal system ,RC925-935 - Abstract
OBJETIVO: Evaluar el resultado clínico y radiológico de 10 pacientes operados por patología degenerativa lumbar, en los que se les realizó artrodesis intersomática con injerto óseo tricortical de cresta ilíaca y artrodesis posterolateral instrumentada con tornillos translaminofacetarios. MÉTODOS: Se evaluaron 10 pacientes, 4 hombres y 6 mujeres operados por el mismo cirujano entre junio de 2006 y diciembre de 2007. RESULTADOS: Se obtuvo un significativo descenso de la discapacidad y del dolor (según las escalas de Oswestry y la escala visual analógica), obteniéndose una tasa de fusión del 100% al año de seguimiento. CONCLUSIONES: Los resultados clínicos y radiológicos de este estudio establecen a éste procedimiento como confiable, de bajo costo y baja morbilidad, con una alta tasa de fusión y buenos resultados clínicos.
- Published
- 2013
- Full Text
- View/download PDF
17. Reduction in radiation (fluoroscopy) while maintaining safe placement of pedicle screws during lumbar spine fusion
- Author
-
Christopher D. Chaput, Keri George, Amer F. Samdani, John I. Williams, John Gaughan, and Randal R. Betz
- Subjects
Fluoroscopía ,Tornillos óseos ,columna vertebral ,Vértebras lumbares ,Exposición a la radiación ,Orthopedic surgery ,RD701-811 ,Diseases of the musculoskeletal system ,RC925-935 - Abstract
OBJECTIVE: The purpose of this study is to report the results using PediGuard (electrical conductivity device) to reduce radiation exposure while drilling the pilot hole for pedicle screw placement. METHOD: Eighteen patients diagnosed with a degenerative lumbar spine, that required a posterior spinal fusion. Average age of the patients were 55 ± 12 years. Patients received postoperative CT scans of all screws. Scans were reviewed by an independent reviewer grading 'in' < 2 mm of breach , or 'out' > 2 mm of breach. In a randomized fashion, the surgeon created pilot holes with either his standard technique or by using the PediGuard. Fluoroscopy was used for each drilling as necessary. Once the pilot hole was created, the surgeon inserted titanium screws into the pedicle pilot holes. A total of 78 screws (39 standard probe and 39 PediGuard ) were analyzed. RESULTS: 78 screws (39 standard probe and 39 PediGuard were analyzed. No significant difference in breach rate > 2mm by either method (p=1.000), with one screw out in each group. Fluoroscopy shots averaged 5.2 (range, 0 to 15), average decrease of 2.3 (30%) per screw in the PediGuard group vs. 7.5 (range, 2 to 17) in the standard group (p< .001). CONCLUSION: This trial to assess pedicle probe location within the pedicle and vertebral body showed the number of fluoroscopy shots were reduced by 30%, compared to a standard probe while maintaining a 97.5% screw placement accuracy.
- Published
- 2013
- Full Text
- View/download PDF
18. RESULTADOS CLÍNICO-RADIOLÓGICOS DEL TRATAMIENTO DE LA ESCOLIOSIS NEUROMUSCULAR CON TORNILLOS S2-ALAR-ILÍACOS GUIADOS POR NAVEGACIÓN INTRAOPERATORIA
- Author
-
Alex Oliveira de Araújo, Claudionor Nogueira Costa Segundo, Ricardo de Amoreira Gepp, and Cícero Ricardo Gomes
- Subjects
Escoliose ,Scoliosis ,Navegación Quirúrgica ,Parafusos ósseos ,Surgical Navigation ,Orthopedics and Sports Medicine ,Surgery ,Escoliosis ,Tornillos Óseos ,Neurology (clinical) ,Navegação Cirúrgica ,Bone screws - Abstract
Objective: Analyze the clinical and radiological aspects of the S2AI screw technique in patients with neuromuscular scoliosis undergoing deformity correction surgery by intraoperative navigation. Methods: Retrospective analysis of medical records of patients undergoing neuromuscular scoliosis correction surgery with the S2-alar-iliac technique between 2017-2020. Results: In the total sample of 35 patients, 18 (51.4%) were female, with an average age of 14.9. The average preoperative coronal curve was 100° ± 26.2, with an average correction of 55% ± 16.3, with an average coronal curve of 44.8°± 19.5 at the end of surgery and 45 ° ± 19.6 at the end of follow-up. The average preoperative pelvic obliquity was 27.9°± 10.9, with a correction rate of 66.1% ± 27.6, being 8.2° ± 5.4 at the end of surgery and 9 .4°± 7.0 at the end of the follow-up. The average of operated levels was 17.3± 0.7. All 70 S2 screws had a diameter of 7mm. The average duration of surgeries was 416 ± 86 minutes, with estimated intraoperative bleeding of 921 ± 394.1 ml. The average density of screws in the sample was 1.3 ± 0.2 screws per level, and the average density in the lumbosacral spine was 1.5 ± 0.2. Conclusions: Intraoperative navigation can contribute to the rate of complications related to the S2AI screw decrease; in addition, the length of this screw appears to have significant relevance in maintaining the correction throughout the follow-up. Level of evidence IV; Case series. Resumo: Objetivo: Analisar os aspectos clínicos e radiológicos da técnica do parafuso S2AI em pacientes com escoliose neuromuscular submetidos à cirurgia de correção de deformidade com auxílio de navegação intraoperatória. Métodos: Análise retrospectiva de prontuários de pacientes submetidos a cirurgia de correção de escoliose neuromuscular com técnica S2-alar-ilíaco entre 2017-2020. Resultados: Do total da amostra de 35 pacientes, 18 (51,4%) eram do sexo feminino, com média de idade de 14,9. A média da curva coronal pré-operatória foi de 100° ± 26,2, com correção média de 55% ± 16,3, com uma média da curva coronal de 44,8°± 19,5 ao final da cirurgia e de 45° ± 19,6 ao final do seguimento. A obliquidade pélvica média pré-operatória foi de 27,9°± 10,9, com uma taxa de correção de 66,1% ± 27,6, sendo de 8,2° ± 5,4 ao final da cirurgia e de 9,4°± 7,0 ao final do seguimento. A média de níveis operados foi de 17,3± 0,7. Todos os 70 parafusos de S2 apresentavam diâmetro de 7mm. O tempo médio de duração das cirurgias foi 416 ± 86 minutos, com estimativa de sangramento intraoperatório de 921 ± 394,1 ml. A densidade média de parafusos da amostra foi de 1.3 ± 0.2 parafusos por nível e a densidade média na coluna lombossacra de 1,5 ± 0,2. Conclusões: A navegação intraoperatória pode contribuir com a diminuição da taxa de complicações relacionadas ao parafuso de S2AI, além disso, que o comprimento deste parafuso aparenta ter uma relevância significativa na manutenção da correção ao longo do seguimento. Nível de evidência IV; Série de casos. Resumen: Objetivo: Analizar los aspectos clínicos y radiológicos de la técnica del tornillo S2AI en pacientes con escoliosis neuromuscular sometidos a cirugía de corrección de deformidades con ayuda de navegación intraoperatoria. Métodos: Análisis retrospectivo de historias clínicas de pacientes sometidos a cirugía de corrección de escoliosis neuromuscular con la técnica S2-alar-ilíaca entre 2017-2020. Resultados: De la muestra de 35 pacientes, 18 (51,4%) eran mujeres, con una edad media de 14,9 años. La curva coronal media preoperatoria fue 100° ± 26,2, con una corrección media del 55% ± 16,3, con una curva coronal media de 44,8° ± 19,5 al final de la cirugía y de 45° ± 19,6 al final del seguimiento. La oblicuidad pélvica preoperatoria media fue de 27,9° ± 10,9, con una tasa de corrección del 66,1% ± 27,6, siendo de 8,2° ± 5,4 al final de la cirugía y de 9,4°± 7,0 al final del seguimiento. El promedio de los niveles operados fue de 17,3± 0,7. Los 70 tornillos S2 tenían un diámetro de 7 mm. La duración promedio de las cirugías fue de 416 ± 86 minutos. Sangrado intraoperatorio estimado de 921 ± 394,1 ml. La densidad media de tornillos en la muestra fue 1,3 ± 0,2 tornillos por nivel y la densidad media en columna lumbosacra fue 1,5 ± 0,2. Conclusiones: La navegación intraoperatoria puede contribuir a la disminución de complicaciones relacionadas con el tornillo S2AI, además, la longitud de este tornillo parece tener una relevancia significativa en el mantenimiento de la corrección durante todo el seguimiento. Nivel de evidencia IV; Series de casos.
- Published
- 2022
19. HOUNSFIELD UNITS USE IN SPINAL SURGERY PLANNING: SYSTEMATIC REVIEW AND META-ANALYSIS
- Author
-
Pedro Luis Bazán, Ricardo Cepeda Jordan, Juan Romel Medina Cevallos, Alfredo Osvaldo Godoy Adaro, and José Carlos Soria Adaro
- Subjects
Tomografía ,Parafusos ósseos ,Tomografia ,Bone Screws ,Cifose ,Densidade Óssea ,Absorciometria de Fóton ,Absorptiometry, Photon ,Bone Density ,Cifosis ,Osteoporosis ,Orthopedics and Sports Medicine ,Surgery ,Neurology (clinical) ,Tornillos Óseos ,Kyphosis ,Osteoporose ,Absorciometría de Fotón ,Tomography ,Densidad Ósea - Abstract
Bone mineral density is a crucial factor in the success or failure of osteosynthesis in spine surgery; it shows the onset of osteoporosis and related complications. Its evaluation is verified by dual-energy X-ray absorptiometry (DEXA) and Hounsfield Unit (HU) measurement by CT scan. Objective: Determine the use of HU in surgical planning; compare utility in diagnosing osteoporosis by DEXA; and evaluate sensitivity in predicting complications. Method: A systemic literature review was conducted on PubMed, in line with PRISMA methodology. Including those who justified the use of pre-surgical planning, compared HU/DEXA, and assessed complications. For the statistical analysis, the χ2 was used. Results: 57 articles were identified by selecting nine that met the inclusion criteria. In patients undergoing spinal surgery for fixation and fusion for degenerative pathology, HU measurement showed a prevalence of osteoporosis of 58.5% (sensitivity 93.26%; specificity 90.22%), osteoporosis-associated complications of 24.5%, proper diagnosis of 71.98%, and screw release rate of 82.31%. Conclusions: UH measurement for the diagnosis of osteoporosis turns out to be more sensitive, specific, and predictive compared to DEXA, especially in elderly patients; it represents a useful tool in planning spinal surgery, minimizing the risk of complications such as screw release, fractures, pseudoarthrosis, subsidence of intersomatic devices, and kyphosis of the proximal junction. Level of evidence II; Study Design: Systematic Review and meta-analysis. Resumo: A densidade mineral óssea é um fator crucial no sucesso ou falha da osteossíntese na cirurgia da coluna vertebral; isso mostra o aparecimento da osteoporose e complicações relacionadas a ela. Sua avaliação é verificada por absorptiometria de raios-X de dupla energia (DEXA) e medição da Unidade Hounsfield (HU) por tomografia. Objetivo: Determinar o uso do HU no planejamento cirúrgico; comparar utilidade no diagnóstico de osteoporose pelo DEXA; e avaliar a sensibilidade na previsão de complicações. Método: Foi realizada uma revisão de literatura sistêmica no PubMed, em consonância com a metodologia PRISMA. Incluindo aqueles que justificaram o uso do planejamento pré-cirúrgico, comparou o HU/DEXA e avaliaram complicações. Para a análise estatística, o χ2 foi usado. Resultados: Inicialmente foram identificados 57 artigos por meio da seleção de nove que atenderam aos critérios de inclusão. Em pacientes submetidos à cirurgia espinhal para fixação e fusão por patologia degenerativa, a medição do HU apresentou prevalência de osteoporose de 58,5% (sensibilidade 93,26%; especificidade 90,22%), complicações associadas à osteoporose de 24,5%, diagnóstico adequado de 71,98% e taxa de liberação de parafusos de 82,31%. Conclusões: A medição da UH para o diagnóstico da osteoporose acaba sendo mais sensível, específica e preditiva em relação ao DEXA, principalmente em pacientes idosos; representa uma ferramenta útil no planejamento da cirurgia espinhal, minimizando o risco de complicações como liberação de parafusos, fraturas, pseudoartrose, subsidência de dispositivos intersomáticos e cifose da junção proximal. Nível de evidência II; Revisão Sistemática e meta-análise. Resumen: La densidad mineral ósea es un factor crucial en el éxito o fracaso de la osteosíntesis en la cirugía espinal; esto muestra la aparición de osteoporosis y las complicaciones relacionadas con ella. Su evaluación se verifica mediante absorciometría de rayos X de energía dual (DEXA) y medición unitaria de Hounsfield (HU) por tomografía. Objetivo: Determinar el uso de HU en la planificación quirúrgica; comparar la utilidad en el diagnóstico de osteoporosis por DEXA; y evaluar la sensibilidad en la predicción de complicaciones. Método: Se realizó una revisión sistémica de la literatura en PubMed, en línea con la metodología PRISMA. Incluyendo aquellos que justificaron el uso de la planificación prequirúrgica, compararon HU/DEXA y evaluaron las complicaciones. Para el análisis estadístico se utilizó χ2. Resultados: Inicialmente se identificaron 57 artículos seleccionando 9 que cumplían con los criterios de inclusión. En pacientes sometidos a cirugía espinal por fijación y fusión por patología degenerativa, la medición de HU mostró una prevalencia de osteoporosis del 58,5% (sensibilidad 93,26%; especificidad 90,22%), complicaciones asociadas a osteoporosis del 24,5%, diagnóstico adecuado del 71,98% y tasa de liberación de tornillo del 82,31%. Conclusiones: La medición de la UH para el diagnóstico de osteoporosis resulta ser más sensible, específica y predictiva en comparación con el DEXA, principalmente en pacientes de edad avanzada; representa una herramienta útil en la planificación de la cirugía espinal, minimizando el riesgo de complicaciones como la liberación del tornillo, fracturas, pseudoartrosis, hundimiento de dispositivos intersomáticos y cifosis de la unión proximal. Nivel de evidencia II; Revisión sistemática y meta-análisis.
- Published
- 2022
20. In vivo studies on flexion and extension of the lumbar spine after stabilisation with a non-fusion pedicle screw system Estudios in vivo de flexión y extensión de la columna lumbar después de estabilización con un sistema de tornillo de pedículo de no fusión Estudos in vivo sobre flexão e extensão da coluna lombar após estabilização com sistema de parafuso pedicular com técnica de não-fusão
- Author
-
Jörg Rainer Klauß, MJ Richter, Hendrik Bergert, Rainer Braunschweig, and Klaus Roehl
- Subjects
Radiografía ,Fijadores internos ,Columna vertebral ,Tornillos óseos ,Radiografia ,Fixadores internos ,Coluna vertebral ,Parafusos ósseos ,Radiography ,Internal fixators ,Spine ,Bone screws ,Orthopedic surgery ,RD701-811 ,Diseases of the musculoskeletal system ,RC925-935 - Abstract
OBJECTIVE: The aim was to determine in vivo whether pre-operative mobility of the lumbar spine (overall and segmental) is retained after surgical intervention. METHODS: Functional imaging of the lumbar spine was performed in flexion and extension, using a lateral projection under standardised conditions. This allowed assessment of the overall mobility, mobility of the instrumented mobile segments and the disc height of the adjacent cranial segment (intervertebral space; IVS) before and after surgical intervention. Images were evaluated independently by a radiologist and an orthopaedic surgeon. A comparative analysis of preoperative and postoperative functional images was carried out with the aid of a computer and appropriate software (ACES) for further assessment of the extent to which the range of movement was retained. The Oswestry Disability Index (ODI, quality of life assessment) and the visual analogue scale (VAS, pain assessment) were used as clinical criteria and compared pre-and postoperatively. The mean follow-up (FU) intervals were 13.5 days (FU 1) and 19 months (FU 2). RESULTS: Radiological results showed that the overall mobility of the lumbar spine (L1 to S1) decreased on average by one third of the flexion/extension range, from 25.0º preoperatively to 17.6º postoperatively. The segmental mobility of the monosegmental stabilisation decreased on average from 3.7º to 2.3º. The caudal segments of the bisegmental dynamic stabilisation retained their preoperative movement range of 2.6º, with a postoperative range of 2.4º. The IVS did not change. The ODI improved postoperatively from 59 (preoperative) to 39/41 (FU1/FU2) points, while the VAS (during movement) improved from 7.6 (pre-op) to 4.4/4.5 (FU1/FU2). Computer-assisted analysis showed that small and functionally insignificant micro-motion of 0.4º (error 0.12%) remained in the stabilised and unfused mobile segment. CONCLUSION: Comparison of preoperative and postoperative measurements showed that overall mobility and segmental micro-motion were retained after non-fusion stabilisation of the lumbar spine with monosegmental and bisegmental instrumentation. The adjacent cranial segment (IVS) did not collapse. Activity levels (ODI) and pain symptoms (VAS) of the patients showed significant improvement at follow-up, comparable to that reported in the literature for conventional rigid spinal fusions.OBJETIVO: Fue determinar in vivo si la movilidad preoperatoria de la espina lumbar (general y segmentaria) se mantiene después de la intervención quirúrgica. MÉTODOS: La representación por imágenes de la espina lumbar se realizó en flexión y extensión, usándose una proyección lateral en condiciones estandarizadas. Esto permitió la evaluación de la movilidad general, la movilidad de los segmentos móviles instrumentados y la altura de disco del segmento craneano adyacente (espacio intervertebral; IVS), antes y después de la intervención quirúrgica. Las imágenes fueron evaluadas, independientemente, por un radiólogo y un cirujano ortopedista. Un análisis comparativo de las imágenes funcionales preoperatorias y posoperatorias fue realizado con la ayuda de una computadora y del software apropiado (ACES) para evaluación adicional de la extensión hasta la cual se mantuvo la amplitud del movimiento. El Índice de Incapacidad de Oswestry (ODI, evaluación de la calidad de vida) y la escala análoga visual (VAS, evaluación del dolor) fueron usados como criterios clínicos y comparados antes y después de la cirugía. Los intervalos promedio de seguimiento (FU) fueron 13,5 días (FU 1) y 19 meses (FU 2). RESULTADOS: Los resultados radiológicos muestran que la movilidad general de la espina lumbar (L1 a S1) se redujo, en promedio, en un tercio de la amplitud de flexión/extensión, de 25,0º antes de la cirugía a 17,6º después de la cirugía. La movilidad segmentaria, de la estabilización monosegmentaria, disminuyó, en promedio, de 3,7º a 2,3º. Los segmentos caudales de la estabilización dinámica bisegmentaria mantuvieron su amplitud de movimiento preoperatorio de 2,6º, con una extensión de 2,4º después de la cirugía. El IVS no cambió. El ODI mejoró después de la cirugía de 59 (preoperatorio) puntos a 39/41 (FU1/FU2), mientras que la VAS (durante el movimiento) mejoró de 7,6 (preoperatoria) a 4,4/4,5 (FU1/FU2). El análisis, con ayuda de la computadora, mostró que un pequeño micromovimiento, funcionalmente insignificante, de 0,4º (error 0,12%) permaneció en el segmento móvil estabilizado y no fusionado. CONCLUSIÓN: La comparación de las mediciones preoperatoria y posoperatoria mostró que la movilidad general y el micromovimiento segmentario fueron mantenidos después de la estabilización no fusionada de la espina lumbar con instrumentación monosegmentaria y bisegmentaria. El segmento craneano adyacente (IVS) no tuvo un colapso. Los niveles de actividad (ODI) y los síntomas de dolor (VAS) de los pacientes mostraron mejoría significativa en el seguimiento, comparable a la que se informa en la literatura para fusiones espinales convencionales, rígidas.OBJETIVO: O objetivo foi determinar in vivo se a mobilidade pré-operatória da coluna lombar (geral e segmentar) é mantida depois da intervenção cirúrgica. MÉTODOS: Foram realizadas imagens funcionais da coluna lombar em flexão e extensão, usando projeção lateral em condições padronizadas. Isso permitiu a avaliação da mobilidade geral, da mobilidade dos segmentos móveis instrumentados e da altura do disco do segmento rostral adjacente (espaço intervertebral; IVS) antes e depois da intervenção cirúrgica. As imagens foram analisadas independentemente por um radiologista e por um cirurgião ortopedista. Realizou-se análise comparativa das imagens funcionais pré e pós-operatórias com o auxílio de computador e de software apropriado (ACES) para avaliar mais detalhadamente a extensão em que a amplitude de movimento foi mantida. O Oswestry Disability Index (ODI, avaliação da qualidade de vida) e a escala visual analógica (VAS, avaliação da dor) foram usadas como critérios clínicos e comparadas no pré e pós-operatório. Os intervalos médios de acompanhamento (FU, de follow-up) foram 13,5 dias (FU 1) e 19 meses (FU 2). RESULTADOS: Os resultados radiológicos mostraram que a mobilidade geral da coluna lombar (L1 a S1) diminuiu, em média, um terço na amplitude de flexão e extensão, de 25,0º antes da cirurgia, para 17,6º depois. A mobilidade dos segmentos na estabilização monossegmentar diminuiu, em média, de 3,7º para 2,3º. Os segmentos caudais da estabilização dinâmica bissegmentar mantiveram a amplitude de movimento pré-cirúrgica de 2,6º, chegando até 2,4º depois da cirurgia. O IVS não foi alterado. O ODI melhorou depois da intervenção, de 59 para 39/41 (FU 1/FU 2) pontos, enquanto a VAS (durante movimento) melhorou de 7,6 (pré-operatório) para 4,4/4,5 (FU 1/FU 2). A análise auxiliada por computador mostrou que o pequeno e funcionalmente insignificante micromovimento de 0,4º (erro de 0,12%) permaneceu no segmento móvel estabilizado com técnica de não-fusão. CONCLUSÃO: A comparação das mensurações pré e pós-operatórias mostrou que a mobilidade geral e o micromovimento segmentar foram mantidos depois de estabilização da coluna lombar com técnica de não-fusão, com instrumentação mono e bissegmentar. O segmento rostral adjacente (IVS) não sofreu colapso. Os níveis de atividade (ODI) e os sintomas dolorosos (VAS) dos pacientes apresentaram melhora significante no acompanhamento, comparável aos relatados na literatura referentes às fusões espinais rígidas convencionais.
- Published
- 2012
- Full Text
- View/download PDF
21. Influência da extensão da artrodese lombossacra nos resultados clínicos e funcionais Influencia de la extensión de la artrodesis lumbosacra en los resultados clínicos y funcionales Influence of the extent of lumbosacral arthrodesis in clinical and functional outcomes
- Author
-
Alberto Ofenhejm Gotfryd, Guilherme Galito Henriques, and Patrícia Rios Poletto
- Subjects
Columna vertebral ,Dolor en la región Lumbar ,Artrodesis ,Descompresión quirúrgica ,Calidad de vida ,Ciática ,Tornillos óseos ,Coluna vertebral ,Dor lombar ,Artrodese ,Descompressão cirúrgica ,Qualidade de vida ,Parafusos ósseos ,Spine ,Low back pain ,Arthrodesis ,Decompression surgical ,Quality of life ,Sciatica ,Bone screws ,Orthopedic surgery ,RD701-811 ,Diseases of the musculoskeletal system ,RC925-935 - Abstract
OBJETIVO: Verificar a influência da extensão da fusão póstero-lateral lombossacra e seu impacto nos resultados clínicos e funcionais. MÉTODOS: Foram avaliados 22 pacientes portadores de estenose central, foraminal ou hérnia de disco lombar, associadas a instabilidade segmentar, submetidos ao tratamento cirúrgico para a descompressão neural e artrodese póstero-lateral. Os pacientes foram divididos em dois grupos, de acordo com quantidade de níveis artrodesados: Grupo 1: fusão em um nível e Grupo 2: fusão em dois ou mais níveis. Os pacientes preencheram questionários referentes ao acompanhamento pós-operatório (uso de medicamentos analgésicos e satisfação com o tratamento) e escala analógica visual de dor lombar e ciática. Além disto, foram aplicados os questionários Oswestry e SF-36 para avaliação da qualidade de vida. RESULTADOS: Os resultados do SF-36 mostraram bons níveis de qualidade de vida em ambos os grupos, com exceção do domínio "Aspectos Físicos". Não houve correlação significativa entre a extensão da artrodese e os desfechos clínicos. CONCLUSÕES: Os pacientes submetidos à artrodese póstero-lateral apresentaram qualidade de vida satisfatória, exceto pela diminuição da aptidão física. Entretanto, o maior número de níveis artrodesados não teve impacto negativo sobre os aspectos clínicos e funcionais.OBJETIVO: Investigar la influencia del grado de la fusión posterolateral lumbosacral y su impacto en los resultados clínicos y funcionales. MÉTODOS: Se evaluaron 22 pacientes con estenosis central, foraminal o hernia de disco lumbar, asociadas a inestabilidad segmentaria; se sometieron a cirugía para la descompresión neural y la artrodesis posterolateral. Los pacientes fueron divididos en dos grupos según el número de niveles fusionados: Grupo 1: la fusión en un nivel, y Grupo 2: la fusión en dos o más niveles. Los pacientes completaron cuestionarios sobre seguimiento posoperatorio (uso de medicamentos analgésicos y satisfacción con el tratamiento) y la escala analógica visual para el dolor lumbar y la ciática. Por otra parte, se aplicaran los cuestionarios Oswestry y SF-36 para evaluar la calidad de vida. RESULTADOS: El SF-36 mostró resultados de buenos niveles de calidad de vida en ambos grupos, excepto en el campo "Aspectos Físicos". No hubo correlación significativa entre la magnitud de la artrodesis y los resultados clínicos. CONCLUSIONES: Los pacientes que fueron sometidos a artrodesis posterolateral mostraron calidad de vida satisfactoria, con excepción de disminución de la aptitud física. Sin embargo, el mayor número de niveles fusionados no tuvo un impacto negativo en los aspectos clínicos y funcionales.OBJECTIVE: Investigate the influence of the extent of posterolateral lumbosacral fusion and its impact on clinical and functional results. METHODS: We evaluated 22 patients with central or foraminal stenosis or lumbar disc herniation associated with segmental instability that underwent to surgery for nerve decompression and posterolateral arthrodesis. Patients were divided into two groups according to the number of levels fused: Group 1: fusion at one level and Group 2: fusion of two or more levels. Patients completed questionnaires regarding postoperative follow-up (use of analgesic medications and treatment satisfaction) and visual analog scale for lumbar pain and sciatica. Moreover, the questionnaires Oswestry and SF-36 were administered to assess quality of life. RESULTS: SF-36 showed good levels of quality of life in both groups, except the field "Physical Aspects". There was no significant correlation between the extent of the arthrodesis and clinical outcomes. CONCLUSIONS: Patients who underwent posterolateral arthrodesis showed satisfactory quality of life, except for a decrease of physical fitness. However, the higher number of levels fused did not have negative impact on clinical and functional aspects.
- Published
- 2012
- Full Text
- View/download PDF
22. Avaliação da trajetória dos parafusos bicorticais pela técnica de harms e melcher em relação à artéria carótida interna: estudo experimental em cadáveres Evaluación de la trayectoria de los tornillos bicorticales en la técnica de harms y melcher en relación con la arteria carótida interna: un estudio experimental en cadáveres Evaluation of the trajectory of the bicortical screws in relation to the internal carotid artery, in fixation by the harms and melcher technique: an experimental study in cadavers
- Author
-
Guilherme Zanini Rocha, Aluízio Augusto Arantes Junior, Cassius Vinicius Correa dos Reis, Sebastião Nataniel Silva Gusmão, Warley Martins, Arthur Adolfo Nicolato, Guilherme Lourenço Lima Reis, Fernando Flavio Vasconcelos Gonçalves, and Julio César Boynard Santiago
- Subjects
Columna vertebral ,Atlas cervical ,Tornillos óseos ,Arteria carótida interna ,Cadáver ,Tomografía ,Coluna vertebral ,Parafusos ósseos ,Artéria carótida interna ,Tomografia ,Spine ,Cervical atlas ,bone screws ,Carotid artery, internal ,Cadaver ,Tomography ,Orthopedic surgery ,RD701-811 ,Diseases of the musculoskeletal system ,RC925-935 - Abstract
OBJETIVO: O objetivo deste trabalho é estudar, em peças anatômicas; a relação entre os parafusos bicorticais pela técnica de Harms e Melcher e a artéria carótida interna. MÉTODOS: Nossa amostra consiste em cinco cadáveres. RESULTADOS: Os resultados encontrados foram: a média da menor distância entre o orifício de saída do parafuso e a borda medial da artéria carótida interna direita foi de 11,55 mm (com variação de 10,05 a 14,23 mm), enquanto do lado esquerdo a média foi de 7,50 mm (variando de 2,75 a 12,42 mm). A média da menor distância entre a borda posterior da artéria carótida interna e a cortical anterior da massa lateral de C1 à direita foi de 4,24 mm (variando de 2,08 a 7,48 mm), enquanto do lado esquerdo a média obtida foi de 2,98 mm (com variação de 1,83 a 3,83 mm). CONCLUSÃO: Os resultados encontrados estão de acordo com os estudos similares existentes na literatura que enfatizam a necessidade de uma avaliação imaginológica criteriosa da posição anatômica da artéria carótida interna antes da utilização de parafusos bicorticais na massa lateral de C1 por via posterior.OBJETIVO: O objetivo de este estudio es, en las piezas anatómicas, la relación entre los tornillos bicorticales, mediante la técnica de Harms y Melcher, y la arteria carótida interna. MÉTODOS: La muestra se compone de cinco cadáveres. RESULTADOS: Los resultados fueron: la distancia más corta promedio, entre la salida del tornillo y el borde medial de la arteria carótida interna derecha, fue 11,55 mm (rango de 10,05 a 14,23 mm), mientras que, en la izquierda, el promedio fue 7,50 mm (rango 2,75 a 12,42 mm). La distancia más corta promedio, entre el borde posterior de la arteria carótida interna y la cortical anterior C1 de la derecha, fue 4,24 mm (que van desde 2,08 hasta 7,48 mm), mientras que, en el lado izquierdo, el promedio fue 2,98 mm. (que van desde 1,83 hasta 3,83 mm). Conclusión: Los resultados son consistentes con estudios similares en la literatura que hacen hincapié en la necesidad de una evaluación cuidadosa de las imágenes y posición anatómica de la arteria carótida interna, antes del uso de tornillos bicorticales de masa lateral de C1 por acceso posterior.OBJECTIVE: The objective of this study is to study the relationship between bicortical screws and the internal carotid artery, in anatomical body parts, in screw fixation by the Harms and Melcher technique. METHODS: Our sample consisted of five cadavers. RESULTS: The results were as follows: the average shortest distance between the outlet of the screw and the medial edge of the right internal carotid artery was 11.55 mm (range 10.05 to 14.23 mm), while on the left side, the average was 7.50 mm (ranging from 2.75 to 12.42 mm). The average shortest distance between the posterior edge of the internal carotid artery and the anterior cortical C1 lateral mass on the right was 4.24 mm (ranging from 2.08 to 7.48 mm), while the left side, the average was 2.98 mm (ranging from 1.83 to 3.83 mm). CONCLUSION: The results are consistent with similar studies in the literature that emphasize the need for a careful assessment of images of anatomical position of the internal carotid artery prior to the use of bicortical screws in the C1 lateral mass by posterior access.
- Published
- 2011
- Full Text
- View/download PDF
23. Artrodesis C1C2 con tornillos transarticulares en artritis reumatoidea: experiencia y revisión de la literatura Artrodese C1 C2 com parafusos transarticulares em artrite reumatoide: experiência e revisão de literatura C1 C2 arthrodesis with transarticular screws in rheumatoid arthritis: experience and literature review
- Author
-
Lyonel Beaulieu Lalanne and Gonzalo Arriagada OcampoII
- Subjects
Artritis reumatoidea ,Tornillos óseos ,Artrodesis ,Artrite reumatóide ,Parafusos ósseos ,Artrodese ,Rheumatoid Arthritis ,Bone screws ,Arthrodesis ,Orthopedic surgery ,RD701-811 ,Diseases of the musculoskeletal system ,RC925-935 - Abstract
OBJETIVO: Describir los resultados clínicos e imagenológicos utilizando la técnica de fijación C1 C2 con tornillos transarticulares y asas de alambre en pacientes portadores de AR en un seguimiento a largo plazo y revisar la literatura actual. MÉTODO: Entre los años 2002 y 2006, 11 pacientes (9 mujeres y 2 hombres) con inestabilidad C1 C2 secundaria a AR fueron intervenidos quirúrgicamente. Se realizó fijación C1 C2 con tornillos transarticulares por vía posterior más asas de alambre y aplicación de injerto óseo autólogo de cresta ilíaca. Se registró Índice de Ranawat pre y posoperatorio, Distancia Anterior Atlas Odontoides (DAAO) pre y posoperatorio, tiempo operatorio, días de hospitalización, complicaciones intra y posoperatorias y tiempo de consolidación radiológica, con un seguimiento promedio de 34 meses. RESULTADOS: Todos los pacientes presentaron mejoría del Índice de Ranawat en el postoperatorio. La DAAO preoperatoria promedio fue de 11,9 mm (DS ± 2,57), rango 7 a 16, y la DAAO postoperatoria promedio fue de 3 mm (DS ± 1,20), rango 2 a 6. El tiempo quirúrgico fue de 94 minutos en promedio y el promedio de días de hospitalización fue de 7 días. No se presentaron complicaciones intraoperatorias. Un caso presentó seroma de herida operatoria que requirió tratamiento quirúrgico. El tiempo de consolidación fue en promedio 14 semanas. CONCLUSIÓN: La artrodesis atlantoaxial con tornillos y amarras es una buena alternativa para el manejo de la inestabilidad C1-C2 en pacientes portadores de AR, consiguiendo buenos resultados clínicos e imagenológicos en un seguimiento a largo plazo.OBJETIVO: Apresentar a experiência com a técnica de fixação C1-C2 com parafusos transarticulares e cerclagem de fio metálico nos pacientes portadores de AR, assim como a revisão da literatura. MÉTODO: Entre os anos 2002 e 2006, 11 pacientes (9 mulheres e 2 homens) com instabilidade C1-C2 e portadores de AR foram submetidos a tratamento cirúrgico. Foi realizada a fixação C1-C2 com parafusos transarticulares por via posterior e cerclagem com fio metálico e enxerto autólogo. O Índice de Ranawat pré e pós-operatorio foi registrado, assim como a distância anterior atlas-dontoide (DAAO), o tempo operatório, os dias de hospitalização, as complicações trans e pós-operatórias e o tempo de consolidação. O seguimento médio foi de 34 meses. RESULTADOS: Todos os pacientes apresentaram melhora do Índice de Ranawat no pós-operatório, a DAAO pré-operatória média foi de 11,9 cm (DP ± 2,57), variação de 7 a 16, e a DAAO pós-operatória média foi de 3 cm (DP ± 1,20), com a variação de 2 a 6. O tempo cirúrgico médio foi de 94 minutos e o período médio de de hospitalização foi 7 dias. Não foram observadas complicações intraoperatórias. Um paciente apresentou seroma de ferida operatória que necessitou de tratamento cirúrgico. O tempo de consolidação foi em média 14 semanas. CONCLUSÃO: A artrodese atlanto-axial com parafusos e cerclagem com fio metálico é uma boa alternativa no tratamento da instabilidade C1-C2 nos pacientes portadores de AR, proporcionando bons resultados clínicos e radiológicos.OBJECTIVE: Present the long term clinical and radiological results in C1-C2 transarticular screws technique with posterior wiring in RA patients and presenting the current literature review. METHODS: From 2002 to 2006, eleven patients (9 women and 2 men) with RA and C1-C2 instability underwent C1-C2 arthrodesis with transarticular screws plus posterior wiring and autologous iliac crest bone graft. A retrospective chart and radiographic review was performed. Ranawat Index was recorded in pre- and post-operative, as well as anterior atlantodental interval (AADI), operating time, days of hospitalization and complications. The mean follow up (FU) was 34 months. RESULTS: All patients presented improved Ranawat Index at follow up. Average pre-operative AADI was 11,9mm (SD ± 2,57), range 7 to 16. Average post-operative AADI was 3mm (SD ± 1.20), range 2 to 6. The average operating time was 94 minutes and the average days of hospitalization was 7 days. No intra-operative complications were found. Post-operative seroma was found in one case and surgical drainage was required. All patients achieved solid fusion at 14 weeks in average. CONCLUSIONS: C1-C2 arthrodesis with transarticular screws plus posterior wiring and autologous bone graft is a good alternative for atlantoaxial instability due RA, with good clinical and radiographic outcomes.
- Published
- 2011
- Full Text
- View/download PDF
24. Tratamento cirúrgico da escoliose idiopática do adolescente utilizando parafusos pediculares: análise dos resultados clínicos e radiográficos Tratamiento quirúrgico de la escoliosis idiopática del adolescente utilizando tornillos pediculares: análisis de los resultados clínicos y radiográficos Surgical treatment of adolescent idiopathic scoliosis using pedicle screws: analysis of clinical and radiographic results
- Author
-
Alberto Ofenhejm Gotfryd, Fernando José Franzin, Giuliana Raucci, Nicola Jorge Carneiro Neto, and Patrícia Rios Poletto
- Subjects
Escoliosis ,Cirugía ,Adolescente ,Resultado del tratamiento ,Tornillos óseos ,Escoliose ,Cirurgia ,Resultado de tratamento ,Parafusos ósseos ,Scoliosis ,Surgery ,Adolescent ,Treatment outcome ,Bone screws ,Orthopedic surgery ,RD701-811 ,Diseases of the musculoskeletal system ,RC925-935 - Abstract
OBJETIVO: Realizar avaliação clínica e radiográfica de pacientes com escoliose idiopática do adolescente (EIA) submetidos à artrodese por via posterior utilizando parafusos pediculares e correlacionar os resultados por imagem com os escores obtidos através do questionário SRS-24. MÉTODOS: Foram avaliados 25 pacientes com diagnóstico de escoliose idiopática do adolescente, submetidos à artrodese da coluna por via posterior com parafusos pediculares. O seguimento médio foi de 23,7 meses, variando entre 12 e 35. Analisamos critérios radiográficos referentes à correção das deformidades e aplicamos o questionário SRS-24, específico para esta doença, padronizado pela Scoliosis Research Society. RESULTADOS: A amostra foi composta por 92% de pacientes do gênero feminino e a média de idade foi de 14,2 anos. A média do índice de Cobb na radiografia ântero-posterior pré-operatória foi de 24,4° para curva torácica proximal, 54,9° para torácica principal e 38,5° para curva lombar. Os valores angulares médios no pós-operatório foram 11,0°; 16,7° e 12,2° respectivamente, com porcentagem de correção média da curva torácica principal de 69,9%. O valor médio final do questionário SRS-24 foi 98,1 pontos. Dois pacientes apresentaram complicações pós-operatórias, entretanto, nenhuma do tipo neurológica. CONCLUSÃO: A técnica se mostrou eficaz para tratamento cirúrgico da EIA, proporcionando alto percentual de correção das deformidades, com baixo risco de complicações e resultado clínico satisfatório. Não foi encontrada relação estatisticamente significante entre a porcentagem de correção da curva (torácica principal ou lombar) ou seu valor angular pós-operatório com o valor final do questionário SRS-24 nem com os domínios "satisfação" e "auto-imagem pós-operatória".OBJETIVO: Evaluar clínica y radiográficamente a pacientes portadores de escoliosis idiopática del adolescente sometidos a artrodesis por vía posterior, utilizando solamente tornillos pediculares, y correlacionar el resultado radiográfico con los valores obtenidos a través del cuestionario SRS-24. Métodos: Fueron evaluados 25 pacientes portadores de escoliosis idiopáticas del adolescente, sometidos a artrodesis de la columna por vía posterior. El seguimiento promedio fue de 23,7 meses, con variación entre 12 y 35. Analizamos criterios radiográficos referentes a la corrección de las deformidades y aplicamos el cuestionario SRS-24, específico para la patología en cuestión, estandarizada por la Scoliosis Research Society. Resultados: La muestra fue compuesta por 92% de pacientes del sexo femenino y el promedio de edad fue 14,2 años. El promedio del índice de Cobb en la radiografía anteroposterior preoperatoria fue de 24,4 grados para la curva torácica proximal, 54,9 grados para torácica principal y 38,5 grados para la curva lumbar. Los valores angulares promedio en el postoperatorio fueron 11 grados, 16,7 grados y 12,2 grados respectivamente, con un porcentaje de corrección promedio de la curva torácica principal de 69,9%. El valor promedio final del cuestionario SRS-24 fue de 98,1 puntos. Dos de los pacientes presentaron complicaciones en el postoperatorio, sin embargo ninguna del tipo neurológico. Conclusión: La técnica se mostró eficaz para el tratamiento quirúrgico de la EIA, proporcionando un alto porcentual de corrección de las deformidades, con un bajo riesgo de complicaciones y resultado clínico satisfactorio. No hubo asociación estadísticamente significativa entre el porcentaje de corrección de la curva (torácica o lumbar principal) o su valor postoperatorio para el valor final del cuestionario SRS-24 ni con los dominios "satisfacción" y "autoimagen postoperatoria".Objective: To evaluate clinically and radiographically patients with adolescent idiopathic scoliosis (AIS) submitted to posterior arthrodesis using pedicle screws-only constructs and correlate image results with SRS-24 scores. METHODS: Twenty five patients with AIS submitted to posterior arthrodesis were evaluated. The follow-up was 23.7 months ranging from 12 to 35. Radiographic criteria were reviewed regarding the deformity correction and a specific questionnaire developed by Scoliosis Research Society (SRS-24) was applied. RESULTS: The sample was composed by 92% females and 8% males. The average age was 14.2 years. The Cobb angle average measured by anterior-posterior roentnogegram was 24.4° at proximal thoracic curve, 54.9° at principal thoracic and 38.5° at the lumbar curve. The mean angular values obtained after the surgery were 11.0°; 16.7° and 12.2° respectively and the average correction of the principal thoracic curve was 69.9%. The mean SRS-24 scores were 98.1 points. Two patients had post-operative complications; however, there were no neurological complications. CONCLUSIONS: The technique showed to be effective on surgical treatment of AIS, with high percentage of deformity correction, low risk of complications and satisfactory clinical results. There was no correlation between the percentage of correction (thoracic or lumbar) and/or the post-operative value of angular deformity and the SRS-24 results, neither with "satisfaction" or "self-image after surgery" domains.
- Published
- 2011
- Full Text
- View/download PDF
25. Influência do local de ancoragem dos implantes na vértebra sobre o torque de inserção e resistência ao arrancamento Influencia de la ubicación de los implantes en la vértebra cuanto al torque de inserción y resistencia de arrancamiento Influence of anatomical vertebral site on screw insertion torque and pull-out strength
- Author
-
Rodrigo César Rosa, Patrícia Silva, Maurício José Falcai, Antônio Carlos Shimano, and Helton Luiz Aparecido Defino
- Subjects
Columna vertebral ,Tornillos óseos ,Biomecánica ,Torque ,Coluna vertebral ,Parafusos ósseos ,Biomecânica ,Spine ,Bone screws ,Biomechanics ,Orthopedic surgery ,RD701-811 ,Diseases of the musculoskeletal system ,RC925-935 - Abstract
OBJETIVO: Avaliar a influência do sítio anatômico da ancoragem dos implantes na vértebra sobre a resistência ao arrancamento e o torque de inserção dos parafusos pediculares com alma cônica e cilíndrica. MÉTODOS: Parafusos cilíndricos e com alma cônica foram inseridos no pedículo e corpo vertebral de 10 vértebras lombares (L4-L5) de vitelos. Foram avaliados o torque de inserção e a resistência ao arrancamento dos parafusos inseridos no corpo e no pedículo vertebral. RESULTADOS: Os valores do torque de inserção e resistência ao arrancamento foram maiores nos parafusos de alma cilíndrica e alma cônica inseridos no pedículo vertebral. CONCLUSÕES: A ancoragem dos implantes no pedículo vertebral apresentou maiores valores do torque de inserção e da força de arrancamento que os implantes inseridos no corpo vertebral nos dois tipos de parafusos utilizados.OBJETIVO: Evaluar la influencia de la localización anatómica de la fijación de los implantes en la vértebra cuanto al torque de inserción y resistencia de arrancamiento de los tornillos con alma cónica y cilíndrica. MÉTODOS: Los tornillos con alma cilíndrica y cónica se insertan en el cuerpo y el pedículo vertebral de diez vértebras lumbares (L4-L5) de los terneros. Se evaluó el torque de inserción y resistencia al arrancamiento de tornillos insertados en el cuerpo y el pedículo. RESULTADOS: El torque de inserción y resistencia al arrancamiento fue mayor para los tornillos con alma cónica y cilíndrica insertados en el pedículo. CONCLUSIONES: La fijación de los implantes en el pedículo mostró mayor torque de inserción y resistencia al arrancamiento en comparación con los implantes en el cuerpo vertebral, en ambos tipos de tornillos.OBJECTIVE: To evaluate the influence of anatomical site of implants on vertebra about insertion torque and pull-out strength of conical and cylindrical core screws. METHODS: Conical and cylindrical core screws were inserted into the pedicle and vertebral body of 10 lumbar vertebrae (L4-L5) of calves. In the study were evaluated insertion torque and pull-out strength of screws inserted into the body and pedicle. RESULTS: The insertion torque and pull-out strength were higher for conical and cylindrical core screws inserted into vertebral pedicle. CONCLUSIONS: The anchoring of implants into the pedicle showed higher insertion torque and pull-out strength than implants inserted into the vertebral body in both types of screws used.
- Published
- 2011
- Full Text
- View/download PDF
26. Avaliação tomográfica do posicionamento de parafusos pediculares em deformidades na coluna torácica e lombar introduzidos com base na técnica 'free hand' Evaluación tomográfica de la colocación de tornillos pediculares en deformidades de la columna torácica y lumbar, introducidos con base en la técnica 'free hand' Tomographic evaluation of the placement of pedicle screws used in deformities of the thoracic and lumbar spine based on the 'free hand' technique
- Author
-
Dante Bernardes Giubilei, Paulo Tadeu Maia Cavali, Maurício Antonelli Lehoczki, Alexander Junqueira Rossato, Marcelo Italo Risso-Neto, Guilherme Rebechi Zuiani, Ivan Guidolin Veiga, Wagner Pasqualini, and Élcio Landim
- Subjects
Vértebras torácicas ,Vértebras lumbares ,Escoliosis ,Tornillos óseos ,Vértebras lombares ,Escoliose ,Parafusos ósseos ,Thoracic vertebrae ,Lumbar vertebrae ,Scoliosis ,Bone screws ,Orthopedic surgery ,RD701-811 ,Diseases of the musculoskeletal system ,RC925-935 - Abstract
OBJETIVO: Avaliar o posicionamento de parafusos pediculares aplicados em vértebras da coluna torácica e lombar em pacientes portadores de escolioses, introduzidos pela técnica "free hand". MÉTODOS: Avaliação de quinze tomografias computadorizadas de 284 parafusos pediculares em 15 pacientes (sete homens e oito mulheres), com idade entre 12 e 39 anos (média de 16,7 anos) com escoliose. Os parafusos foram inseridos de T2 a S1 para as seguintes afecções: duas escolioses congênitas e 13 escolioses neuromusculares, visando avaliar o posicionamento dos parafusos com relação às paredes dos pedículos. RESULTADOS: Em relação às corticais do pedículo, 244 parafusos (86%) foram posicionados entre as corticais ou apenas as tocaram. Houve lesão da cortical lateral em 16 parafusos e lesão da cortical medial em 13 parafusos, sendo maior o número de violações nas vértebras torácicas. CONCLUSÃO: O uso de parafusos pediculares na instrumentação de vértebras torácicas e lombares nas escolioses mostrou -se segura e efetiva quando aplicado em diferentes níveis com a técnica "free hand''. Nas vértebras torácicas as violações da cortical pedicular foram mais frequentes, mas não prejudicaram a estabilidade da fixação e não lesaram estruturas neurais, vasculares e viscerais.OBJETIVO: Evaluar la colocación de tornillos pediculares utilizados en las vértebras de la columna torácica y lumbar en pacientes con escoliosis, introducidos mediante la técnica "free hand". MÉTODOS: Se evaluaron quince tomografías computadorizadas de 284 tornillos pediculares en 15 pacientes (siete hombres y ocho mujeres), de edades comprendidas entre 12 y 39 años (promedio de 16,7 años), que tenían escoliosis. Los tornillos se insertaron desde T2 a S1, siendo dos escoliosis congénitas y 13 escoliosis neuromusculares; se analizó la colocación de los tornillos en relación a las paredes de los pedículos. RESULTADOS: Cuanto a las corticales del pedículo, 244 (86%) de los parafusos fueron colocados entre las corticales o apenas las tocaron. Lesión cortical lateral se observó en 16 tornillos y lesión cortical medial en 13 tornillos. Fue mayor el número de violaciones torácicas. CONCLUSIÓN: El uso de tornillos pediculares en la instrumentación de las vértebras torácicas y lumbares en la escoliosis demostró ser seguro y eficaz cuando se aplican a diferentes niveles con la técnica de "free hand''. En las vértebras torácicas, las violaciones de la cortical pedicular fueron más frecuentes, pero sin poner en peligro la estabilidad de la fijación y sin dañar estructuras neurales, vasculares y viscerales.OBJECTIVE: To evaluate the placement of pedicle screws in the vertebrae of the thoracic and lumbar spine in patients with scoliosis using the"free hand" technique. METHODS: Evaluation of CT scans of 284 pedicle screws in 15 patients (seven men and eight women) aged between 12 and 39 years (mean 16.7 years) with scoliosis. The screws were inserted from T2 to S1 for the following conditions: two congenital scoliosis and 13 neuromuscular, to evaluate the placement of screws in relation to the walls of pedicles. RESULTS: Regarding the cortical pedicle screws, 244 (86%) were positioned between the cortical or just touching it. Lateral cortical lesion was seen in 16 screws and medial cortex lesion in 13 screws, being greater the number of violations in the thoracic vertebrae. CONCLUSION: The use of pedicle screw instrumentation in thoracic and lumbar vertebrae for scoliosis proved safe and effective when applied to different levels with the "free hand" technique. In the thoracic vertebrae, the pedicular cortical violations were more frequent, but did not impair the stability of fixation and did not injure the neural, vascular and visceral structures.
- Published
- 2011
- Full Text
- View/download PDF
27. Influência do instrumento de perfuração do orifício piloto nas propriedades mecânicas dos parafusos vertebrais Influencia de la herramienta de perforación del orificio piloto en las propiedades mecánicas de los tornillos vertebrales Effect of the pilot hole perforation tool on mechanical properties of vertebral screws
- Author
-
Rodrigo César Rosa, Patrícia Silva, Antônio Carlos Shimano, and Helton Luiz Aparecido Defino
- Subjects
Columna vertebral ,Tornillos Óseos ,Biomecánica ,Coluna vertebral ,Parafusos ósseos ,Biomecânica ,Spine ,Bone screws ,Biomechanics ,Orthopedic surgery ,RD701-811 ,Diseases of the musculoskeletal system ,RC925-935 - Abstract
OBJETIVO: Determinar a influência do modo de preparo do orifício piloto utilizando sonda romba, sonda cortante e broca na resistência ao arrancamento dos implantes. MÉTODO: Foram utilizados parafusos do sistema de fixação vertebral (USS) com 5 mm, 6 mm e 7 mm de diâmetro externo. Os parafusos foram implantados nos corpos de prova de osso bovino após a realização do orifício piloto com três diferentes modos de preparo: sonda romba, sonda cortante e broca. O diâmetro de perfuração do orifício piloto era menor, igual e maior que o diâmetro interno dos parafusos. No mesmo corpo de prova, três orifícios do mesmo diâmetro foram confeccionados por meio dos três modos de preparo utilizados no estudo, os parafusos foram inseridos e, em seguida, foram realizados os ensaios mecânicos de arrancamento. Os ensaios mecânicos foram realizados em máquina universal de ensaio Emic®, Software Tesc 3.13, célula de carga de 2000N, velocidade de aplicação de força de 2 mm/min, pré-carga de 5N e tempo de acomodação de 10 segundos. A propriedade avaliada nos ensaios mecânicos foi a força máxima de arrancamento. RESULTADOS: O modo de preparo do orifício piloto influencia na resistência ao arrancamento dos implantes de 5 e 6 mm utilizados no estudo. Foi observada maior resistência ao arrancamento os orifícios piloto que foram confeccionados com sonda. A resistência ao arrancamento dos parafusos de 7 mm não foi influenciada pelo modo de preparo do orifício piloto. CONCLUSÃO: O modo de preparo do orifício piloto influenciou a resistência ao arrancamento dos parafusos de 5 e 6 mm de diâmetro externo.OBJETIVO: Determinar la influencia del modo de preparar el orificio piloto por medio de punzón de punta roma, punzón de punta cortante y broca, en la resistencia al arrancamiento de los implantes. MÉTODO: Se utilizó el sistema de tornillos de fijación vertebral (USS), con 5 mm, 6 mm y 7 mm de diámetro exterior. Los tornillos se implantaron en las muestras de hueso bovino después de hacerse el orificio piloto con tres modos diferentes de preparación: punzón de punta roma, punzón cortante y broca. El diámetro de la perforación del orificio piloto fue menor, igual y mayor que el diámetro interior de los tornillos. En el mismo cuerpo de la prueba, tres orificios de igual diámetro fueron preparados mediante los tres modos de preparación utilizados en el estudio; los tornillos fueron insertados y, enseguida, fueron realizados los ensayos mecánicos de arrancamiento. Los ensayos mecánicos fueron realizados en una máquina universal de ensayo Emic®, Software Tesc 3.13, con una célula de carga de 2000 N, una velocidad de aplicación de fuerza de 2 mm/min, una precarga de 5 N y un tiempo de acomodación de 10 segundos. La propiedad evaluada en los ensayos mecánicos fue la fuerza máxima de arrancamiento. RESULTADOS: El método de preparación del orificio piloto influye en la resistencia de arrancamiento de los tornillos de 5 y 6 mm utilizados en el estudio. Fue observada mayor resistencia al arrancamiento cuando los orificios piloto fueron hechos con sonda. Los medios de la preparación de los orificios piloto no influyen en la resistencia al arrancamiento de los tornillos de 7 mm. CONCLUSIÓN: El método de preparación del orificio piloto influyó en la resistencia al arrancamiento de los tornillos 5 y 6 mm de diámetro exterior.OBJECTIVE: To evaluate the effect of the pilot hole preparation technique using a blunt probe, a sharp probe and a drill on pullout strength of vertebral screws. METHODS: Screws of the USS vertebral fixation system measuring 5, 6 and 7 mm in outer diameter were used. The screws were implanted into bovine bone samples in which pilot holes were prepared with blunt probes, sharp probes and drills. The diameter of the pilot hole was smaller, equal to or wider than the inner diameter of the screw. Three holes of the same diameter were made in the same bone sample by the three preparation techniques. The screws were inserted and pullout mechanical tests were performed using an Emic® universal testing machine, Tesc 3.13 software, a 2000 N load cell, a 2 mm/min rate of force application, a 5 N preload and a 10 second time of accommodation. The property assessed in the mechanical tests was maximum pullout strength. RESULTS: The pilot hole preparation technique and the hole diameter in relation to inner screw diameter affected the pullout strength of 5 and 6 mm screws, which was greater for screws inserted into pilot holes prepared with a probe. No significant difference between preparation techniques of pilot hole was observed for 7 mm screws. CONCLUSION: The technique of pilot hole preparation influenced the pullout strength of 5 and 6 mm screws. No difference was observed for 7 mm screws.
- Published
- 2011
- Full Text
- View/download PDF
28. Bilateral fracture of L5 pedicles in a patient with total disc replacement of L5-S1: a case report
- Author
-
Jorge Alberto De Haro Estrada, Javier Ramos Fernandez, Juan Carlos Alvarez Garnier, Michael Dittmar Johnson, and Francisco Cruz Lopez
- Subjects
Disco intervertebral ,Columna vertebral ,Fusión vertebral ,Tornillos óseos ,Orthopedic surgery ,RD701-811 ,Diseases of the musculoskeletal system ,RC925-935 - Abstract
Report of a rare complication - fracture of the pedicles - in a patient with total disc replacement of L5-S1, a surgical resolution, and a biomechanical explanation. To the authors' knowledge, there is only one previous report of bilateral fracture of the pedicles in the literature, as a complication in total disc replacement of the lumbar spine. In this case, no direct repair was made to the fracture site; instead intersomatic fusion was performed by the anterior approach. A 40-year-old male, a martial arts practitioner who had undergone L5-S1 (ProDisc(r)) disc replacement nine months earlier, with complete resolution of the preoperative symptoms and no complications, sudden pain during physical activity, without neurological symptoms. Computed axial tomography showed a fracture of the L5 pedicles and anterior luxation of the polyethylene insert. Surgery was performed by the posterior approach, with direct repair of the fractures and posterolateral fusion of L5-S1 with transpedicular screws (Schanz) and USS(r) internal fixator. A follow-up axial CT scan at 6 months after surgery showed complete consolidation of the fractures, and the patient was asymptomatic. Due to the alteration in weight transmission through the anterior part of the spine in the total replacement of the lumbar disc, which preserves the movement but not the absorption of forces, the pedicle becomes more susceptible to fracture. It is important to bear this complication in patients submitted to this procedure.
- Published
- 2014
- Full Text
- View/download PDF
29. Análise do diâmetro transverso do processo odontoide com uso da tomografia computadorizada Análisis del diámetro transverso del proceso odontoides con uso de la tomografía computarizada Analysis of the transverse diameter in the odontoid process by computerized tomography
- Author
-
Fábio Kazuo Soejima, Carlos Henrique Maçaneiro, Rodrigo Fetter Lauffer, and Marco Antônio Rodacki
- Subjects
Columna vertical ,Proceso odontoides ,Fijación de las fraturas ,Tornillos Óseos ,Tomografía computarizada por rayos X ,Coluna vertebral ,Processo odontoide ,Fixação de fraturas ,Parafusos ósseos ,Tomografia computadorizada por raios X ,Spinal cord ,Odontoid process ,Fracture fixation ,Bone screws ,Tomography, x-ray, computed ,Orthopedic surgery ,RD701-811 ,Diseases of the musculoskeletal system ,RC925-935 - Abstract
INTRODUÇÃO: o diâmetro reduzido do odontoide é um desafio para o cirurgião no planejamento pré-operatório e escolha na fixação da fratura com um ou dois parafusos. OBJETIVO: analisar a medida do diâmetro transverso (DT) do processo odontoide por meio da tomografia computadorizada para o planejamento pré-operatório da osteossíntese com um ou dois parafusos. MÉTODOS: foram analisadas 79 tomografias computadorizadas cervicais de pacientes adultos, sem deformidades congênitas ou queixas de dor em coluna cervical alta, atendidos em uma clínica privada de Blumenau - Santa Catarina. RESULTADOS: as médias de idade não revelaram diferença estatisticamente significante entre os sexos, mas observou-se diferença estatisticamente significante entre as médias do DT do odontoide de homens e mulheres. A média do diâmetro transverso nos homens foi de 10,29 mm, e nas mulheres de 9,39 mm. CONCLUSÃO: a tomografia computadorizada mostrou-se útil para a medição do diâmetro transverso do processo odontoide. A fixação com um parafuso cortical de 3,5 mm seria possível em todos os casos analisados e a fixação com dois parafusos seria possível em 83,9% dos homens e 62,5% das mulheres.INTRODUCCIÓN: el diámetro reducido de la odontoides es un desafío para el cirujano en la planificación pre-operatoria y de la elección en la fijación de la fractura con uno o dos tornillos. OBJETIVO: analizar la medida del diámetro transverso (DT) del proceso odontoides, por medio de la tomografía computarizada para el planeamiento pre-operatorio de la osteosíntesis con uno o dos tornillos. MÉTODOS: fueron analizadas 79 tomografías computarizadas cervicales de pacientes adultos, sin deformidades congénitas o reclamos de dolor en la columna cervical alta, atendidos en una clínica privada de Blumenau - Santa Catarina, Brasil. RESULTADOS: los promedios de edad no revelaron diferencia estadísticamente significante entre los sexos, pero se observó diferencia estadísticamente significante entre los promedios del DT de la odontoides de hombres y mujeres. El promedio del DT en los hombres fue de 10,29 mm, y en las mujeres de 9,39 mm. CONCLUSIÓN: la tomografía computarizada se mostró útil para la medición del diámetro transverso del proceso odontoides. La fijación con un tornillo cortical de 3,5 mm sería posible en todos los casos analizados y la fijación con dos tornillos sería posible en el 83,9% de los hombres y el 62,5% de las mujeres.INTRODUCTION: the reduced diameter of the odontoid is a challenge for the surgeon in preoperative planning and in choosing between the fixation of the fracture with one or two screws. OBJECTIVE: to analyze the transverse diameter (TD) of the odontoid process by computerized tomography (CT) for preoperative planning of osteosynthesis with one or two screws. METHODS: Seventy-nine cervical CT scans of adults without congenital malformations or complaints of pain in the upper cervical spine, treated at a private clinic in Blumenau - Santa Catarina, Brazil were analyzed. RESULTS: the mean age revealed no statistically significant difference between the sexes, but there was a statistically significant difference between the average TD of the odontoid of men and women. The TD average in men was of 10.29 mm, and in women it was of 9.39 mm. CONCLUSION: computerized tomography proved to be useful for measuring the odontoid process. The fixation with a 3.5 mm cortical screw would be possible in all examined cases, and the fixation with two screws would be possible in 83.9% of the men and 62.5% of the women.
- Published
- 2010
- Full Text
- View/download PDF
30. Parafuso pedicular: método para correção da deformidade na escoliose idiopática do adolescente Tornillo pedicular: método para corregir la deformidad en la escoliosis idiopática del adolescente Pedicular screw: method to correct the deformity in adolescent idiopatic scoliosis
- Author
-
Raphael de Rezende Pratali, Marcelo Italo Risso Neto, Ivan Guidolin Veiga, Wagner Pasqualini, Paulo Tadeu Maia Cavali, Marcus Alexandre Mello Santos, Alexander Junqueira Rossato, Maurício Antonelli Lehoczki, and Élcio Landim
- Subjects
Escoliosis ,Curvatura de la columna vertebral ,Fusión vertebral ,Instrumentos quirúrgicos ,Tornillos óseos ,Escoliose ,Curvatura da coluna vertebral ,Fusão vertebral ,Instrumentos cirúrgicos ,Parafusos ósseos ,Scoliosis ,Spinal curvatures ,Spinal fusion ,Surgical instruments ,Bone screws ,Orthopedic surgery ,RD701-811 ,Diseases of the musculoskeletal system ,RC925-935 - Abstract
OBJETIVO: avaliar retrospectivamente o poder de correção da deformidade escoliótica em pacientes tratados cirurgicamente com instrumental de terceira geração sendo utilizados exclusivamente parafusos pediculares tanto nas curvas torácicas quanto nas lombares. MÉTODOS: dezessete pacientes com escoliose idiopática do adolescente (EIA) foram submetidos a tratamento cirúrgico, com correção da deformidade e artrodese via posterior com parafusos pediculares em todas as vértebras. Foram analisados sexo, idade, linha de Risser e classificação da escoliose pelo sistema de Lenke. As curvas foram comparadas entre si no pré e pós-operatório em relação ao grau da curvatura pelo método de Cobb, sua flexibilidade por meio de radiografias em inclinação, translação vertebral apical (AVT, do inglês apical vertebral translation) e rotação vertebral apical (AVR, do inglês apical vertebral rotation). A porcentagem de correção pós-operatória foi analisada por meio do "índice de correção de Cincinnati" (ICC). RESULTADOS: houve correção significativa no ângulo de Cobb nas curvas maiores (pOBJETIVO: evaluar retrospectivamente la facultad de corregir la deformidad de escoliosis en los pacientes tratados quirúrgicamente con instrumento de tercera generación se utilizando exclusivamente los tornillos de pedículo, tanto en las curvas torácicas como en las lumbares. MÉTODOS: diecisiete pacientes con escoliosis idiopática del adolescente fueron tratados quirúrgicamente, con la corrección de la deformidad y artrodesis posterior con tornillos pediculares en todas las vértebras. Se analizaron sexo, edad, línea de Risser y clasificación de la escoliosis por el sistema de Lenke. Las curvas fueron comparadas antes y después de la cirugía en relación con el grado de curvatura por el método de Cobb, su flexibilidad con las radiografías en la pendiente, la traslación vertebral apical (AVT, sigla del inglés apical vertebral translation) y la rotación vertebral apical (AVR, del inglés apical vertebral rotation). El porcentaje de corrección postoperatoria fue analizado con el "índice de corrección de Cincinnati" (CPI). RESULTADOS: se observó una corrección significativa en el ángulo de Cobb en las curvas de mayor (pOBJECTIVE: to evaluate retrospectively the power of scoliotic deformity in patients that were submitted to surgical treatment with third generation instrumentation using exclusively pedicle screws in both thoracic and lumbar curves. METHODS: seventeen patients with adolescent idiopathic scoliosis (AIS) were submitted to surgical treatment with deformity correction and fusion by posterior approach with pedicle screws in all vertebral bodies. Sex, age, Risser line and Lenke system of classification were analyzed. The curves were compared between pre and postoperatory in relation to Cobb angle, curve flexibility by the bending radiographs, apical vertebral translation (AVT) and apical vertebral rotation (AVR). The postoperative correction percentage was expressed by the Cincinnati correction index (CCI). RESULTS: the Cobb angle had significant correction in the major curves (p
- Published
- 2010
- Full Text
- View/download PDF
31. Monitoração intraoperatória com teste de estimulação eletromiográfica dos instrumentais de pacientes submetidos à correção cirúrgica de escoliose idiopática Seguimiento de estimulación intraoperatoria con electromiografía de los instrumentales de pacientes sometidos a corrección quirúrgica de la escoliosis idiopática Intraoperative neurophysiological monitoring of patients undergoing idiopathic scoliosis surgical correction
- Author
-
Wagner Pasqualini, Marcos Antonio Tebet, Marcio Oliveira Penna de Carvalho, Rubens Massaru Kanno, and Alfredo Torres Castellon
- Subjects
Monitoreo intraoperatorio ,Escoliosis ,Electromiografía ,Tornillos óseos ,Neurofisiología ,Potenciales evocados motores ,Monitorização intra-operatória ,Escoliose ,Eletromiografia ,Parafusos ósseos ,Neurofisiologia ,Potencial evocado motor ,Monitoring, intraoperative ,Scoliosis ,Electromyography ,Bone screws ,Neurophysiology ,Evoked potentials, motor ,Orthopedic surgery ,RD701-811 ,Diseases of the musculoskeletal system ,RC925-935 - Abstract
OBJETIVO: apresentar a metodologia empregada na monitoração neurofisiológica de pacientes submetidos a tratamento para correção de escoliose idiopática com instrumentação cirúrgica, utilizando parafusos pediculares torácicos e lombares. MÉTODOS: foram estudados, retrospectivamente, 32 prontuários de pacientes operados no Serviço de Cirurgia da Coluna Vertebral do Instituto da Coluna,Jundiaí, São Paulo, entre os anos de 2004 e 2008. A idade variou de 11 a 18 anos, e a maioria era do sexo feminino (93,75%). RESULTADOS: verificou-se que em seis pacientes houve relação entre a incidência de positividade no teste com estimulação eletromiográfica dos instrumentais e mau posicionamento dos parafusos pediculares, sem evidências de complicações após correção dos mesmos. CONCLUSÃO: os resultados confirmam a eficácia da monitoração intraoperatória.OBJETIVO: presentar la metodología utilizada en la vigilancia neurofisiológica de los pacientes sometidos al tratamiento de corrección de la escoliosis idiopática, con el uso de instrumentación quirúrgica, utilizando tornillos pediculares torácicos y lumbares. MÉTODOS: se estudiaron 32 pacientes operados en el Servicio de Cirugía del Raquis del Instituto de la Columna (Jundiaí), en el Brasil, entre 2004 y 2008. Las edades oscilaban entre los 11 a 18 años y la mayoría era mujeres (93,75%). RESULTADOS: se ha detectado en seis pacientes la relación entre la incidencia de positivo en la prueba de estimulación con electromiografía de los instrumentales y la mala colocación de los tornillos pediculares, sin evidencias de complicaciones después de la corrección de los mismos. CONCLUSIÓN: los resultados confirman la eficacia de la monitorización intraoperatoria.OBJECTIVE: to present the methodology used for neurophysiological monitoring of patients undergoing idiopathic scoliosis correction with surgical instrumentation, using thoracic and lumbar pedicle screws. METHODS: retrospective study of the medical records of 32 patients submitted to surgery at the Spine Surgery Service of Instituto da Coluna, Jundiaí, São Paulo, Brazil, from 2004 to 2008. Ages ranged from 11 to 18 years, and the majority of the patients was female (93.75%). RESULTS: a correlation between positive clinical findings and pedicle screw malposition was found in six patients submitted to electromyographic stimulation instruments test, with no evidence of complications after correction of screw position. CONCLUSION: results confirm the efficacy of intraoperative monitoring.
- Published
- 2010
- Full Text
- View/download PDF
32. Estudo biomecânico comparativo da resistência a forças de compressão entre os parafusos pediculares poliaxiais com travamento tipo Dytech® e parafusos pediculares poliaxiais com travamento tipo Lock 1® Estudio biomecánico comparativo de la resistencia a fuerzas de compresión entre los tornillos pediculares poliaxiales con traba tipo Dytech® y tornillos pediculares poliaxiales con traba tipo Lock 1® Biomechanical comparative study of compression strength between poliaxial screws Dytech® Locked type and poliaxial screws Lock 1®
- Author
-
Mauricio Pagy de Calais Oliveira, Luiz Cláudio de Moura França, Marcelo Gonçalves Ruggani, Luiz Olímpio Garcia Pedrosa, Bruno Pinto Coelho Fontes, Rodrigo D'Alessandro de Macedo, Rafael Gonçalves Duarte, and Marcelo Gonçalves Pereira Duarte
- Subjects
Tornillos óseos ,Placas óseas ,Fijación interna de fracturas ,Titanio ,Biomecánica ,In vitro ,Parafusos ósseos ,Placas ósseas ,Fixação interna de fratura ,Titânio ,Biomecânica ,Bone screws ,Bone plates ,Fracture fixation, internal ,Titanium ,Biomechanics ,Orthopedic surgery ,RD701-811 ,Diseases of the musculoskeletal system ,RC925-935 - Abstract
OBJETIVO: Comparar a rigidez de um sistema de fixação pedicular composto por parafusos pediculares poliaxiais de travamento tipo Dytech® com outro composto por parafusos pediculares poliaxiais com travamento do tipo Lock 1®, submetidos a forças de compressão. MÉTODOS: A amostra utilizada para avaliar os sistemas de fixação respeitou as regras do padrão formulado pela American Society for Testing Materials (ASTM) no ensaio F1717-04. Os modelos foram divididos em: Grupo 1, composto pelos ensaios de parafusos poliaxiais com sistema Dytech® de travamento, e o Grupo 2, formado por parafusos poliaxiais com travamento tipo Lock 1®. Foram testados três conjuntos completos montados. Cada sistema foi testado uma única vez por ser esse um ensaio destrutivo. O instrumental implantado foi produzido com titânio de mesma origem. Os grupos experimentais foram submetidos a testes mecânicos na máquina universal de ensaios EMIC, modelo EMIC DL 10000®. RESULTADOS: Os resultados de compressão nas amostras do Grupo 1 tiveram uma carga máxima média de 967,17 N e carga de escoamento média de 804,71 N. Nas amostras do Grupo 2 tivemos uma carga máxima média de 906,04 N e carga de escoamento média de 834,56 N. A respeito da integridade dos instrumentais metálicos usados, não foi observado nenhum tipo de escorregamento ou soltura de porcas, parafusos ou outros componentes. CONCLUSÃO: O sistema de parafusos poliaxiais com travamento tipo Dytech® apresentou valores de rigidez maiores, enquanto o sistema de parafusos com travamento tipo Lock 1® mostrou deslocamento máximo maior.OBJETIVO: comparar la rigidez de un sistema de fijación pedicular compuesto por tornillos pediculares poliaxiales de traba tipo Dytech® con otro compuesto por tornillos pediculares poliaxiales con traba del tipo Lock 1®, sometidos a fuerzas de compresión. MÉTODOS: la muestra utilizada para evaluar los sistemas de fijación respetó las reglas del patrón formulado por la American Society for Testing Materials (ASTM) en el ensayo F1717-04. Los modelos fueron divididos en: Grupo 1, compuesto por los ensayos de tornillos poliaxiales con sistema Dytech® de traba, y el Grupo 2, formado por tornillos poliaxiales con traba tipo Lock 1®. Fueron probados tres conjuntos completos montados. Cada sistema fue probado una vez por ser ese un ensayo destructivo. El instrumental implantado fue producido con titanio del mismo origen. Los grupos experimentales fueron sometidos a pruebas mecánicas en la máquina universal de ensayos EMIC, modelo EMIC DL 10000®. RESULTADOS: los resultados de compresión en las muestras del Grupo 1 tuvieron una carga máxima promedio de 967.17 N y carga de declive promedio de 804.71 N. En las muestras del Grupo 2, tuvimos una carga máxima promedio de 906.04 N y carga de declive promedio de 834.56 N. Con respecto a la integridad de los instrumentales metálicos usados, no fue observado ningún tipo de deslizamiento o soltura de tuercas, tornillos y otros componentes. CONCLUSIÓN: el sistema de tornillos poliaxiales con traba tipo Dytech® presentó valores de rigidez mayores, mientras que el sistema de tornillos con traba tipo Lock 1® mostró un desplazamiento mayor.OBJECTIVE: To compare rigidity of a pedicle fixation system composed of poliaxial pedicle screws with Dytech® lock system to one composed of poliaxial screws with Lock 1® system, submitted to compression strengths. METHODS: The sample used to evaluate the fixation systems respected the norms of the standard described by the American Society for Testing Materials (ASTM) in trial F1717-04. The models were divided into: Group 1, composed of trials using poliaxial screws with Dytech® system, and Group 2, used poliaxial screws with Lock 1® system. Three complete sets were tested. Each system was tested only once because it´s a destructive essay. The implanted components were produced with titanium coming from the same origin. The experimental groups were submitted to mechanical tests in a universal testing machine EMIC, model EMIC DL 10000®. RESULTS: The samples of Group 1 showed an average maximum charge of 967,17 N, and an average discharging load of 814,71 N. The samples of Group 2 showed an average maximum charge of 906,04 N, and an average discharging load of 834,56 N. About the integrity of the used metallic components, was not noted any kind of failure in all of them. CONCLUSION: The pofilaxial screws system with Dytech® lock has presented greater rigidity, while the Lock 1® system screws showed greater maximum displacement.
- Published
- 2010
- Full Text
- View/download PDF
33. Estudo biomecânico comparativo da resistência à força de compressão entre os parafusos pediculares monoaxiais com travamento interno único e parafusos pediculares monoaxiais com travamento duplo interno e externo Estudio biomecánico comparativo de la resistencia a la fuerza de compresión entre los tornillos pediculares monoaxiales con traba interna única y tornillos pediculares monoaxiales con traba dupla interna y externa Biomechanical comparative study of compression strength between single locked monoaxial screws and double locked monoaxial screws
- Author
-
Luiz Cláudio de Moura França, Mauricio Pagy de Calais Oliveira, Marcelo Rugani, Luiz Olimpio Garcia Pedrosa, Rodrigo D'Alessandro Macedo, Bruno Fontes, Marcelo Gonçalves Pereira Duarte, and Rafael Gonçalves Duarte
- Subjects
Tornillos óseos ,Placas óseas ,Fijación interna de fracturas ,Parafusos ósseos ,Placas ósseas ,Fixação interna de fraturas ,Bone screws ,Bone plates ,Fracture fixation ,internal ,Orthopedic surgery ,RD701-811 ,Diseases of the musculoskeletal system ,RC925-935 - Abstract
OBJETIVO: comparar a rigidez de um sistema de instrumentação da coluna vertebral composto por parafusos pediculares fixos com duplo bloqueio (interno e externo) com um sistema composto por parafusos pediculares fixos com bloqueio interno único, submetidos a forças de compressão. MÉTODOS: o modelo experimental utilizado nesses testes para avaliação dos sistemas de fixação foi elaborado de acordo com as normas descritas pela American Society for Testing Materials (ASTM) no ensaio F1717-04. Foram montados dois grupos, sendo o Grupo 1 composto pelos ensaios com parafusos fixos com sistema de duplo bloqueio e o Grupo 2, com parafusos fixos com bloqueio interno único. Foram utilizados três conjuntos de hastes e parafusos para cada grupo. Cada conjunto foi submetido a um teste biomecânico. Os componentes metálicos utilizados foram todos produzidos pela mesma empresa, apresentando mesma origem em relação à matéria-prima. Os modelos experimentais foram submetidos a testes mecânicos na máquina universal de ensaios EMIC, modelo EMIC DL 10000. RESULTADOS: os resultados obtidos no ensaio de compressão nas amostras do Grupo 1 apresentaram uma carga máxima média de 2104,15 N e uma carga de escoamento média de 1882,55 N. Os resultados obtidos no ensaio de compressão nas amostras do Grupo 2 apresentaram uma carga máxima média de 1420,5 N e uma carga de escoamento média de 1314,37 N. CONCLUSÃO: o sistema de parafusos fixos com duplo bloqueio (Grupo 1) apresentou maior resistência a forças de compressão quando comparado ao sistema de parafusos com travamento interno isolado.OBJETIVO: comparar la rigidez de un sistema de instrumentación de la columna vertebral, compuesto por tornillos pediculares fijos con duplo bloqueo (interno y externo), con un sistema compuesto por tornillos pediculares fijos con bloqueo interno único, sometidos a fuerzas de compresión. MÉTODOS: el modelo experimental utilizado en estos testes para evaluación de los sistemas de fijación fue elaborado de acuerdo con las normas descritas por la American Society for Testing Materials (ASTM) en el ensayo F1717-04. Fueron formados dos grupos, siendo el Grupo 1 compuesto por los ensayos con tornillos fijos con sistema de duplo bloqueo, y el Grupo 2, tornillos fijos con bloqueo interno único. Fueron utilizados tres conjuntos de astas y tornillos para cada grupo. Cada conjunto fue sometido a un test biomecánico. Los componentes metálicos utilizados fueron todos producidos por la misma empresa, con mismo origen en relación a la materia prima. Los modelos experimentales fueron sometidos a testes mecánicos en la máquina universal de ensayos EMIC, modelo EMIC DL 10000. RESULTADOS: los resultados obtenidos en el ensayo de compresión en las muestras del Grupo 1 tuvieron una carga máxima promedio de 2104.15 N y una carga de declive promedio de 1882.55 N. Los resultados obtenidos en el ensayo de compresión en las muestras del Grupo 2 tuvieron una carga máxima promedio de 1420.50 N y una carga de declive promedio de 1314.37 N. CONCLUSIÓN: el sistema de tornillos fijos con duplo bloqueo (Grupo 1) presentó mayor resistencia a las fuerzas de compresión cuando comparado a los tornillos con traba interna aislada.OBJECTIVE: to compare the rigidity of a pedicle fixation system composed of fixed pedicle screws with double locked system (internal and external) to one composed of fixed pedicle screws with single internal locked system, submitted to compression strengths. METHODS: the experimental model used to evaluate the fixation systems was constructed according to the standard described by the American Society for Testing Materials (ASTM) in trial F1717-04. The samples were divided into two groups. Group 1 was composed of tests with fixed screws with double locked system; in Group 2 fixed screws with single internal locked system were used. Three sets of rods and screws were used for each group; these sets were submitted to a biomechanical test. The metallic components were produced by the same company and with the same origin. The experimental groups were submitted to mechanical tests at the universal testing machine EMIC, model EMIC DL 10000. RESULTS: the results obtained in the compression trial in samples of Group 1 showed an average maximum charge of 2104,15 N and an average discharging load of 1882,55 N. The results obtained in the compression trial in the samples of Group 2 showed an average maximum charge of 1420,5 N and an average discharging load of 1314,37 N. CONCLUSION: the screws with double locked system (Group 1) presented greater resistance to compression strengths when compared to the screws with single internal locked system.
- Published
- 2010
- Full Text
- View/download PDF
34. Utilización de un nuevo tornillo expansivo en pacientes con mala calidad ósea: estudio multicéntrico
- Author
-
Manuel Rovira Gutierrez, Manuel Fernandez Gonzalez, Julio Villar Perez, Luis Perez Varela, Luis Hernandez Pascua, Jose Alia Benitez, Esteban Dominguez Ignacio, Jose Jaime Quintana Cruz, Lorenzo Zuñiga Gomez, and Enrique Izquierdo Nuñez
- Subjects
Artrodesis ,Columna vertebral ,Tornillos óseos ,Complicaciones postoperatorias ,Osteoporosis ,Orthopedic surgery ,RD701-811 ,Diseases of the musculoskeletal system ,RC925-935 - Abstract
OBJETIVO: Observar el comportamiento del tornillo expansivo en pacientes con mala calidad ósea, su seguridad, técnica, manejo y complicaciones: porcentaje de aflojamiento, roturas, "pull-out" y pseudartrosis. MÉTODOS: Realizamos estudio prospectivo multicéntrico analizando factores de riesgo del paciente, VAS, tiempo quirúrgico, pérdida de sangre, emplazamiento de tornillos y complicaciones debidas al implante a la alta y a los 3, 12 y 24 meses. RESULTADOS: El 99% de los pacientes no tuvieron ninguna complicación permanente relacionada con el implante; sólo hubo un caso de radiculopatía no resuelta. En el 95% de los implantes, los tornillos se colocaron sin complicaciones; en el 5% aparecieron complicaciones relacionadas con la mala colocación o expansión del tornillo, resueltas en acto quirúrgico. Tiempo quirúrgico promedio por nivel, 56 min.; tiempo promedio por intervención, 2 horas 35 min. Sangramiento promedio por nivel intervenido, 211cc. Hemos tenido tres casos de "pull-out". El VAS evolucionó favorablemente de forma significativa, con reducciones promedio mayores a cuatro puntos. El estudio continuará hasta los cinco años, siendo estos los resultados preliminares. CONCLUSIONES: Este tipo de tornillos expansivos aportan un nuevo sistema de anclaje para pacientes con mala calidad ósea; son seguros y eficaces, ofrecen rapidez en su colocación, una menor exposición a los RXy, en caso de retirada del tornillo, dejan el camino libre para una nueva cirugía.
- Published
- 2013
- Full Text
- View/download PDF
35. Control radiografico postoperatorio de la instrumentacion con tornillos pediculares toracicos en la escoliosis idiopática del adolescente
- Author
-
Pablo Fiorillo and Hernan Hector Demonti
- Subjects
Escoliosis ,Adolescente ,Tornillos Óseos ,Tomografía ,Orthopedic surgery ,RD701-811 ,Diseases of the musculoskeletal system ,RC925-935 - Abstract
OBJETIVO: Evaluar la eficacia intraoperatoria y postoperatoria de la radiografía en la colocación del tornillo pedícular dorsal y su relación con la tomografía computada (CT). MÉTODOS: Se evaluaron 36 pacientes con escoliosis idiopática del adolescente (EIA). Tres observadores clasifican colocación de los tornillos con radiografia . Estas respuestas se compararon con la tomografía computada. RESULTADOS: Se evaluaron un total de 280 tornillos pediculares. La evaluación interobservador fue de 0,56 (concordancia moderada). La evaluación intraobservador fue 0,79 (concordancia). No se presentaron lesiones vasculares o neurológicas. CONCLUSIONES: Según los resultados intra e interobservador, la reproductibilidad de la radiografía postoperatoria no es muy eficaz para el diagnósticar la mala posición de los tornillos de pedículo dorsales. La tomografía computada fue muy útil para determinar la posición de los tornillos pediculares dorsales.
- Published
- 2013
- Full Text
- View/download PDF
36. Correção da cifose de Scheuermann: estudo comparativo da fixação híbrida com ganchos e parafusos versus fixação apenas com parafusos Corrección de la cifosis de Scheuermann: estudio comparativo de la fijación híbrida con ganchos y tornillos versus fijación solo con tornillos Correction of Scheuermann kyphosis: comparative study of hybrid fixation using hooks and screws versus screw-only fixation
- Author
-
Enguer Beraldo Garcia, Sebastião Vasconcelos de Souza, Roberto Garcia Gonçalves, Ramon Teodoro Silveira, Eduardo Beraldo Garcia, Liliane Faria Garcia, and Juliana Faria Garcia
- Subjects
Cifosis ,Columna vertebral ,Enfermedad de Scheuermann ,Dispositivos de fijación ortopédica ,Tornillos óseos ,Procedimientos ortopédicos ,Cifose ,Coluna vertebral ,Doença de Scheuermann ,Dispositivos de fixação ortopédica ,Parafusos ósseos ,Procedimentos ortopédicos ,Kyphosis ,Spine ,Scheuermann disease ,Orthopedic fixation devices ,Bone screws ,Orthopedic procedures ,Orthopedic surgery ,RD701-811 ,Diseases of the musculoskeletal system ,RC925-935 - Abstract
OBJETIVOS: avaliar o grau de correção da cifose de Scheuermann, em 6 pacientes que se submeteram à instrumentação híbrida composta por ganchos e parafusos (H) e 17 fixados apenas com parafusos (P). MÉTODOS: 23 pacientes, com cifose de Scheuermann, submetidos a tratamento cirúrgico por dupla via com início pela via anterior, seguido pela via posterior. Do conjunto de pacientes, 6 foram operados com fixação híbrida e 17 com uso exclusivo de parafusos pediculares. O tratamento cirúrgico foi indicado para cifose rígida, variando de 60º e 105º e portadores do sinal de Risser acima de 4. RESULTADOS: observou-se, no Grupo H, cifose pré-operatória média de 84,17º e no pós-operatório de 47,5º. No Grupo P, a média de cifose no pré-operatório era de 80,35º e, no pós-operatório, de 33,53º. CONCLUSÃO: concluiu-se que os dois tipos de fixação apresentaram resultados muito satisfatórios, contudo, sendo ainda superior quando fixados só com parafusos.OBJETIVO: evaluar el grado de corrección de la cifosis de Scheuermann, en seis pacientes que se sometieron a la instrumentación híbrida compuesta por ganchos y tornillos (H) y 17 fijados solamente con tornillos (P). MÉTODOS: fueron veintitrés pacientes, con cifosis de Scheuermann, sometidos al tratamiento quirúrgico por dupla vía con inicio por la vía anterior seguido por la posterior. Del conjunto de pacientes, 6 fueron operados con fijación híbrida y 17 con uso exclusivo de tornillos pediculares. El tratamiento quirúrgico fue indicado para cifosis rígida, variando de 60º a 105º y portadores de la Señal de Risser por encima de 4. RESULTADOS: se observó, en el Grupo H, una cifosis preoperatoria promedio de 84.17º y en el postoperatorio de 47.5º. En el Grupo P el promedio de la cifosis en el preoperatorio era de 80.35º y en el postoperatorio de 33.53º. CONCLUSIÓN: los dos tipos de fijación presentaron resultados muy satisfactorios; no obstante, fue superior con la fijación solo con tornillos.OBJECTIVE: to evaluate the degree of correction of Sheuermann kyphosis, in 6 patients who were submitted to surgery using hybrid instrumentation comprised of hooks and screws (H), and 17 patients undergoing screw-only fixation (P). METHODS: 23 patients with Scheuermann kyphosis were submitted to surgical treatment using anterior and posterior approach. In the present study, we indicated surgical treatment for rigid kyphosis, varying between 60º and 105º. All patients presented a Risser signal above 4. Liberation and Fusion were realized through anterior approach, followed by fixation, deformity correction, and arthrodesis through posterior approach. RESULTS: in Group H, a preoperative kyphosis of 84.17º and a postoperative of 47.5º were observed. In Group P, a preoperative kyphosis of 80.35º and postoperative of 33.53º were observed. CONCLUSION: it was concluded that both types of fixation presented very satisfactory results, with screw only fixation being superior.
- Published
- 2009
- Full Text
- View/download PDF
37. Estudo microscópico da interface implante-osso vertebral e sua relação com o modo de preparo do orifício piloto Estudio microscópico de la interface implante hueso vertebral y su relación con el modo de preparación del orificio piloto Microscopical study of the bone screw interface and its correlation with the pilot hole preparation
- Author
-
José Roberto Benites Vendrame, Sérgio Brito Garcia, José Antonio Thomazini, Michel Carrijo Lutfala, and Helton LA Defino
- Subjects
Columna vertebral ,Fusión vertebral ,Vértebras lumbares ,Tornillos óseos ,Cadáver ,Coluna vertebral ,Fusão vertebral ,Vértebras lombares ,Parafusos ósseos ,Spine ,Spinal fusion ,Lumbar vertebrae ,Bone screws ,Cadaver ,Orthopedic surgery ,RD701-811 ,Diseases of the musculoskeletal system ,RC925-935 - Abstract
OBJETIVO: estudar as alterações do tecido ósseo da interface entre o implante e o osso da vértebra submetido ao preparo do orifício piloto por meio de sonda, broca e broca seguida de macheamento. MÉTODOS: foram utilizadas três vértebras lombares (l2-L3-L4) de cadáveres humanos adultos do sexo masculino. No interior dos pedículos vertebrais, foram inseridos parafusos de 6 mm de diâmetro externo do sistema USIS de fixação vertebral. O preparo do orifício piloto para a inserção dos parafusos nos pedículos vertebrais foi realizado por meio de sonda, broca ou broca seguida de macheamento. As vértebras foram preparadas para o estudo em microscopia de luz e foi avaliado o coeficiente de fragmentação por meio da relação entre a porcentagem da área ocupada por tecido ósseo na região próxima do implante e no osso normal. RESULTADOS: o coeficiente de fragmentação foi menor, com diferença estatística, no grupo do orifício piloto preparado com sonda em relação ao orifício piloto preparado com broca ou broca seguida de macheamento. CONCLUSÃO: o menor coeficiente de fragmentação observado com a utilização da sonda para a realização do orifício piloto indica a maior compactação do osso na interface entre o implante e o osso da vértebraOBJETIVO: estudiar las alteraciones del tejido óseo de la interfase entre el implante y el hueso de la vértebra, sometido al preparo del orificio piloto por medio de sonda, broca y broca seguida de aplastamiento. MÉTODOS: fueron utilizadas tres vértebras lumbares (L2-L3-L4) de cadáveres humanos adultos del sexo masculino. En el interior de los pedículos vertebrales fueron insertados tornillos de 6 mm de diámetro externo del sistema USIS de fijación vertebral. El preparo del orificio piloto, para la inserción de los tornillos en los pedículos vertebrales, fue realizado por medio de sonda, broca o broca seguida de aplastamiento. Las vértebras fueron preparadas para el estudio en microscopio de luz y fue evaluado el coeficiente de fragmentación por medio de la relación entre el porcentaje del área ocupada por el tejido óseo en la región próxima del implante y en el hueso normal. RESULTADOS: el coeficiente de fragmentación fue menor con diferencia estadística en el grupo del orificio piloto preparado con sonda, cuando comparado con el orificio piloto preparado con broca o broca seguida de aplastamiento. CONCLUSIÓN: el menor coeficiente de fragmentación observado con la utilización de la sonda para la realización del orificio piloto indica la mayor compactación del hueso, en la interface entre el implante y el hueso de la vértebra.OBJECTIVE: to access microscopically bone tissue changes between vertebral bone and implant interface, whose pilot hole was prepared using probe, drill and drill followed by tapping. METHODS: the vertebral pedicles of three segments (L2-L3-L4) of human adult cadaver lumbar spine were instrumented with 6 mm USIS pedicle screw. The pilot holes for screw insertion into pedicles were prepared using probe, drill and drill followed by tapping. The vertebrae were prepared to histological study on light microscopy and the fragmentation index assessed by percentage relation between bone tissue close to the implant and normal bone. RESULTS: the fragmentation index of pilot holes prepared with probes was statistically lower than those prepared with drill and drill followed by tapping. CONCLUSION: the low fragmentation index observed that the use of probe to perform pilot hole promotes higher compaction of bone between the screw and vertebral bone interface.
- Published
- 2009
- Full Text
- View/download PDF
38. Parafusos automacheantes: comparação mecânica no modelo artificial de osso e na vértebra cervical de carneiro Tornillos autoterrajante: comparación mecánica en el modelo artificial de hueso y en la vértebra cervical de oveja Self-tapping screws: mechanical analysis in the model of artificial bone and in the cervical sheep vertebra
- Author
-
Patrícia Silva, Rodrigo César Rosa, João Paulo Placo, Antonio Carlos Shimano, Francisco José Albuquerque de Paula, José Batista Volpon, and Helton LA Defino
- Subjects
Columna ,Tornillos óseos ,Biomecánica ,Torque ,Coluna vertebral ,Parafusos ósseos ,Biomecânica ,Spine ,Bone screws ,Biomechanics ,Orthopedic surgery ,RD701-811 ,Diseases of the musculoskeletal system ,RC925-935 - Abstract
OBJETIVO: comparar o novo parafuso travado na placa cervical (CSLP) automacheante com o parafuso convencional cortical automacheante utilizado na fixação da placa cervical anterior, por meio da análise do torque de inserção e da resistência ao arrancamento dos implantes. MÉTODOS: 15 parafusos corticais automacheantes e 15 parafusos CSLP automacheantes foram inseridos em 15 modelos artificiais de osso (poliuretana) e 15 vértebras cervicais de carneiro. Os parâmetros estudados foram o torque de inserção e a força de arrancamento. Foram formados dois grupos experimentais, de acordo com o tipo de parafuso utilizado: Grupo I, com parafuso cortical automacheante; Grupo II, com parafuso CSLP automacheante. O orifício-piloto foi perfurado com 10,0 mm de profundidade, por meio de broca com diâmetro de 2,5 mm (Grupo I) e 3,0 mm (Grupo II). O torque de inserção foi mensurado durante a implantação dos parafusos e, em seguida, foram realizados ensaios mecânicos em máquina universal de testes, para avaliar a força de arrancamento dos implantes. RESULTADOS: os parafusos automacheantes CSLP apresentaram valores do torque de inserção e resistência ao arrancamento maiores que os parafusos corticais automacheantes. CONCLUSÃO: o desenho do parafuso CSLP influencia o seu torque de inserção e resistência ao arrancamento, sendo a avaliação desses parâmetros superiores aos parafusos corticais automacheantes.OBJETIVO: comparar el nuevo tornillo cervical spine locking plate (CSLP) autoterrajante con el convencional tornillo cortical autoterrajante utilizado en la fijación de la placa cervical anterior, por medio del análisis del torque de inserción y de la resistencia al arrancamiento de los implantes. MÉTODOS: quince tornillos corticales autoterrajante y 15 tornillos CSLP autoterrajante fueron inseridos en 15 modelos artificiales de hueso (poliuretana) y 15 vértebras cervicales de oveja. Los parámetros estudiados fueron el torque de inserción y la fuerza de arrancamiento. Fueron formados dos grupos experimentales de acuerdo con el tipo de tornillo utilizado: Grupo I-Tornillo cortical autoterrajante; Grupo II-tornillo CSLP autoterrajante. El orificio-piloto fue perforado con 10.0 mm de profundidad por medio de una broca con diámetro de 2.5 mm (Grupo I) y 3.0 mm (Grupo II). El troque de inserción fue medido durante la implantación de los tornillos y en seguida fueron realizados ensayos mecánicos en máquina universal de test para evaluar la fuerza de arrancamiento de los implantes. RESULTADOS: los tornillos autoterrajante CSLP presentaron valores del torque de inserción y resistencia al arrancamiento mayores que los tornillos corticales autoterrajante. CONCLUSIÓN: el diseño del tornillo CSLP influye en su troque de inserción y resistencia al arrancamiento, siendo la evaluación de estos parámetros superiores a los tornillos corticales autoterrajante.OBJECTIVE: compare the new self-tapping cervical spine locking plate (CSLP) screw with traditional self-tapping cortical screw used in anterior cervical locking plates in terms of insertion torque and pullout strength. METHODS: 15 traditional self-tapping cortical screws and 15 new self-drilling CSLP screws were inserted into 15 models of artificial bone (polyurethane) and 15 cervical vertebrae of sheep. The studied parameters were the insertional torque and pullout strength. The following groups were created, in agreement with the type of screw used: Group I, of self-tapping cortical screw; and Group II, with self-tapping CSLP screw. The pilot hole had 10.0 mm in depth and was made with a 2.5 mm (Group I) and 3.0 mm (Group II) drill. The insertional torque was measured and the pullout test was performed. RESULTS: the CSLP self-tapping screw presented a higher insertional torque and pullout strength compared to cortical self-tapping screws. CONCLUSION: the thread design of CSLP screw influenced the insertional torque and pullout resistance, and the evaluation of these parameter were superior to cortical self-tapping screw.
- Published
- 2009
- Full Text
- View/download PDF
39. Características morfológicas da pars de C2 de humanos Características morfológicas de la pars de C2 de humanos Morphologic characteristics of C2 humans pars
- Author
-
Charles André Carazzo, Vinícius Monteiro de Paula Guirado, Alexandre Meluzzi, Edson Aparecido Liberti, Mario Rubem Pena Dias, Ricardo Bragança de Vasconcelos Fontes, and Mario Augusto Taricco
- Subjects
Vértebras cervicales ,Columna vertebral ,Tornillos óseos ,Fusión vertebral ,Humanos ,Vértebras cervicais ,Coluna vertebral ,Parafusos ósseos ,Fusão vertebral ,Cervical Vertebrae ,Spine ,Bone screws ,Spinal fusion ,Humans ,Orthopedic surgery ,RD701-811 ,Diseases of the musculoskeletal system ,RC925-935 - Abstract
OBJETIVO: avaliar a morfometria da pars da segunda vértebra cervical, verificar as variações existentes e predizer sua segurança para a colocação de parafusos por meio de uma abordagem cervical posterior. MÉTODOS: 58 vértebras foram obtidas para estudo anatômico (116 pars de C2) e foram medidas a altura e largura da pars, além do comprimento eixo-pedículo, largura e comprimento do pedículo, angulação sagital e medial. Todas as medidas foram separadas quanto aos seus lados direito e esquerdo; foi realizado o cálculo da média, variação, desvio padrão e a médica foi comparada com os estudos prévios. RESULTADOS: a largura média da pars de C2 foi de 9,5 mm; a altura, 9,5 mm; não houve diferença significativa entre os lados esquerdo e direito. O comprimento médio do pedículo foi de 10,5 mm; a medida média encontrada para o comprimento eixo-pedículo foi de 24,9 mm; a largura do pedículo foi de 2,8 mm. A angulação sagital encontrada foi de 19,6º e a horizontal foi de 28,5º. CONCLUSÕES: este estudo demonstra a viabilidade para a colocação de parafuso na pars de C2 em uma população caucasiana, destacando-se, porém, a grande variabilidade anatômica encontrada nas referidas medidas.OBJETIVO: evaluar la morfometría de la pars de la segunda vértebra cervical, verificar las variaciones existentes y predecir su seguridad para la colocación de los tornillos por un abordaje cervical posterior. MÉTODOS: 58 vértebras fueron obtenidas para el estudio anatómico (116 pars de C2) y fueron medidas su altura y el ancho de las pars, además de la largura eje-pedículo, ancho y largura del pedículo, ángulo sagital y medial. Todas las medidas fueron separadas según sus lados derecho e izquierdo, se realizó el cálculo de la media, variación, desvío estándar y comparados los valores con estudios previos. RESULTADOS: el ancho promedio de la pars de C2 fue de 9.5 mm, la altura de 9.5 mm, sin diferencia significativa entre los lados izquierdo y derecho. La largura promedio del pedículo fue de 10.5 mm y la medida promedio encontrada para la largura eje-pedículo fue de 24.9 mm, además del ancho del pedículo que fue de 2.8 mm. El ángulo sagital encontrado fue de 19.6° y de la horizontal de 28.5°. CONCLUSIÓN: este estudio demuestra la viabilidad para la colocación de tornillos en la pars de C2 en una población caucásica, pero destacándose la gran variabilidad anatómica encontrada en las medidas referentes.OBJECTIVE: to evaluate de morphometry of the pars of the second cervical vertebra, assess the variations existent and predict its safety for the placement of screws through a posterior cervical approach. METHODS: 58 vertebrae were obtained for anatomic study (116 pars of C2) and measured the height and width of the pars, besides the length of the axis-pedicle, width and length of the pedicle, sagittal and medial angulations. All measurements were separated as to their right and left sides, completed the calculation of media, variation, standard deviation and compared to previous studies. RESULTS: the medium width of the pars of C2 was 9,5 mm, the height, 9,5 mm, without significant difference between right and left sides. The medium length of the pedicle was 10.5 mm and the medium measurement found for the length axis-pedicle was of 24.9 mm and the width of the pedicle was of 2.8 mm. The sagittal angulation found was of 19.6º and the horizontal was of 28.5º. CONCLUSIONS: this study demonstrates the viability of positioning screws in the pars of C2 in a Caucasian population, emphasizing, however, the great anatomic variability found in the referred measurements.
- Published
- 2009
- Full Text
- View/download PDF
40. Artrodese cervical anterior em três e quatro níveis com dispositivo intersomático não associado à placa cervical Artrodesis cervical anterior en tres y cuatro niveles con dispositivo intersomático no asociado a placa cervical Anterior cervical arthrodesis for three and four levels using stand-alone interbody cages without cervical plates
- Author
-
Marcel Luiz Benato, Ed Marcelo Zaninell, Xavier Soler i Graells, and Marcos Andre Sonagli
- Subjects
Fusión vertebral ,Artrodesis ,Vértebras cervicales ,Placas óseas ,Tornillos óseos ,Estudios de seguimiento ,Fusão vertebral ,Artrodese ,Vértebras cervicais ,Placas ósseas ,Parafusos ósseos ,Seguimentos ,Spinal fusion ,Arthrodesis ,Cervical vertebrae ,Bone plates ,Bone screws ,Follow-up studies ,Orthopedic surgery ,RD701-811 ,Diseases of the musculoskeletal system ,RC925-935 - Abstract
OBJETIVO: avaliar a taxa de consolidação em pacientes submetidos à artrodese cervical anterior de três e quatro níveis utilizando dispositivo intersomático não associado à placa cervical no sexto mês de pós-operatório. MÉTODOS: no período de Novembro de 2005 a Julho de 2008, 20 pacientes foram submetidos ao tratamento cirúrgico proposto. Os critérios de inclusão foram: diagnóstico clínico e por imagem de doença discal degenerativa cervical em três ou quatro níveis; dor axial e/ou irradiada com, no mínimo, seis meses de pós-operatório. O critério de exclusão foi a presença de instabilidade cervical traumática. Foram avaliadas as taxas de consolidação, a presença de sintomas, a taxa de complicações e a posição dos dispositivos intersomáticos (subsidence) após seis meses. RESULTADOS: todos os pacientes obtiveram consolidação em três meses, porém, dois pacientes apresentaram fenômeno de subsidence, ou seja, migração com consolidação em cifose, sem alterar os resultados clínicos e a consolidação da artrodese após seis meses de pós-operatório. Os pacientes tiveram melhora da dor pré-operatória e apenas três (15%) apresentaram dor residual. Não houve complicações maiores. O tempo de hospitalização foi de dois dias. Não foi utilizada imobilização rígida no pós-operatório. CONCLUSÃO: obteve-se consolidação com esta técnica em todos os casos. A técnica se mostrou segura e promoveu bons resultados radiológicos e clínicos.evaluar la tasa de consolidación en pacientes sometidos a la artrodesis cervical anterior, de tres y cuatro niveles utilizando dispositivo intersomático no asociado a la placa cervical, después de seis meses de postoperatorio. MÉTODOS: en el período de Noviembre de 2005 a Julio de 2008, 20 pacientes fueron sometidos al tratamiento quirúrgico propuesto. Los criterios de inclusión fueron: diagnóstico clínico y por imagen de enfermedad discal degenerativa cervical en tercer y cuarto niveles; dolor axial y/o irradiada; con mínimo seis meses de postoperatorio. El criterio de exclusión fue la presencia de inestabilidad cervical traumática. Fueron evaluadas las tasas de consolidación, la presencia de síntomas, la tasa de complicaciones y la posición de los dispositivos intersomáticos (subsidente) después de seis meses. RESULTADOS: todos los pacientes obtuvieron consolidación en tres meses, sin embargo, dos pacientes presentaron el fenómeno de subsidente, o sea, migración con consolidación en cifosis, sin alterar los resultados clínicos y la consolidación de la artrodesis a los seis meses de postoperatorio. Los pacientes presentaron mejoría del dolor preoperatorio y solo tres (15%) presentaron dolor residual. No hubo complicaciones mayores. El tiempo de hospitalización fue de dos días. No fue utilizada inmovilización rígida en el postoperatorio. CONCLUSIÓN: fue obtenida consolidación con esta técnica en todos los casos. La técnica se mostró segura y promovió buenos resultados radiológicos y clínicos.evaluate the rates of fusion of the anterior cervical discectomy and arthrodesis for three and four levels using interbody cages (stand-alone) without cervical plates six months after post-operative. METHODS: from November 2005 to July 2008, 20 patients were treated as proposed. The inclusion criteria were: cervical degenerative disease of three and four levels; axial and/or irradiated pain at least six months of follow-up. The exclusion criteria were: cervical traumatic instability. The fusion rate, clinical symptoms, rate of complications and the implant position were evaluated six months after post-operative. RESULTS: results were favorable in 100% of the patients, with residual pain in two cases. Fusion was found in 100% of the patients, except for two cases with minimum subsidence and fusion in a slight kyphotic position. There were not significant complications. The discharge of the hospital was performed within two days. CONCLUSION: The technique is safe and produced good functional and radiological results.
- Published
- 2009
- Full Text
- View/download PDF
41. Influência do macheamento na interface do parafuso e do tecido ósseo na fase imediata pós-implante Influencia del taladramiento en la interfase del tornillo y del tejido óseo durante la fase inmediata post implante The influence of tapping techniques on the interface bone screw/bone tissue in immediate postoperative period
- Author
-
Fabiano Pinheiro de Lemos Masson, Antônio Carlos Shimano, and Helton LA Defino
- Subjects
Columna vertebral ,Tornillos óseos ,Fusión vertebral ,Coluna vertebral ,Parafusos ósseos ,Fusão vertebral ,Spine ,Bone screws ,Spinal fusion ,Orthopedic surgery ,RD701-811 ,Diseases of the musculoskeletal system ,RC925-935 - Abstract
OBJETIVO: analisar experimentalmente as alterações agudas da interface entre o osso e o implante nas vértebras cervicais após a realização do macheamento do orifício piloto. MÉTODOS: foram utilizados cinco carneiros da raça Santa Inês deslanados. Na terceira vértebra cervical, foram feitos orifícios de 2,5 mm, de ambos os lados, na parte proximal e distal. No orifício proximal direito, foi realizado o macheamento antes da inserção do parafuso cortical de 3,5 mm (Grupo A); no orifício proximal esquerdo, o parafuso foi inserido sem macheamento (Grupo B); os outros dois orifícios distais foram utilizados como controle (Grupo C). As alterações da interface entre o osso e o implante foram analisadas por meio de estudo histomorfométrico, considerando o número de trabéculas fraturadas entre os filetes de rosca; a maior distância da fratura trabecular transversal provocada pela inserção do parafuso; a maior extensão da fratura trabecular longitudinal provocada pela inserção do parafuso e a linha de contato na interface osso-parafuso. RESULTADOS: o macheamento do orifício piloto provocou alterações da microestrutura do tecido ósseo ao redor do implante quando comparado às alterações produzidas pela inserção do parafuso sem o macheamento ou orifício piloto. A avaliação do contato entre o osso e o implante foi o parâmetro que apresentou diferença estatística na comparação entre a colocação do implante com e sem machemanto. CONCLUSÃO: na comparação com o orifício piloto, todos os parâmetros analisados apresentaram diferença estatística.OBJETIVO: analizar experimentalmente las alteraciones agudas de la interfase entre el hueso y el implante en las vértebras cervicales, después de taladrar el orificio piloto. MÉTODOS: fueron utilizados cinco carneros de la raza Santa Inés sin lana. En la tercera vértebra cervical, fueron realizados en ambos lados unos orificios de 2.5 mm en la parte proximal y distal. En el orificio proximal derecho fue realizado el taladramiento antes de la inserción del tornillo cortical de 3.5 mm (Grupo A), en el orificio proximal izquierdo el tornillo fue insertado sin taladramiento (Grupo B) y los otros dos orificios distales fueron utilizados como controles (Grupo C). Las alteraciones de la interfase entre el hueso y el implante fueron analizadas por medio de un estudio histomorfométrico, teniendo en cuenta el número de trabéculas fracturadas entre los filetes de rosca; la mayor distancia de la fractura trabecular transversal provocada por la inserción del tornillo; la mayor extensión de la fractura trabecular longitudinal provocada por la inserción del tornillo y la línea de contacto en la interfase hueso-tornillo. RESULTADOS: taladrar el orificio piloto ha provocado alteraciones de la microestructura del tejido óseo alrededor del implante cuando comparado con las alteraciones producidas por la inserción del tornillo sin el taladramiento o el orificio piloto. La evaluación del contacto entre el hueso y el implante fue el parámetro que presentó diferencia estadística en la comparación entre la colocación del implante con o sin taladramiento. CONCLUSIÓN: al comparar con el orificio control, todos los parámetros presentaron diferencia estadística.OBJECTIVE: to analyze experimentally the early alterations of the bone-screw interface with tapping techniques in the cancellous bone of the cervical vertebrae. METHODS: five wooless sheep (Santa Inês) were analyzed. Pilot holes of 2.5 mm were performed at both sides of the third cervical vertebrae in the proximal and distal portion. The tapping process was done in the right proximal hole before the 3.5 mm screw insertion (Group A), while the left proximal hole was not tapped (Group B) and the two distal holes were used as control (Group C). The interface alterations between bone and screw were analyzed through histomorphometric study, considering the number of trabeculae fractures between the screw pitch; the highest distance of transversal trabeculae fracture caused by the screw insertion; the greatest extension of the longitudinal trabeculae fracture caused by the screw insertion and the contact line between bone and screw. RESULTS: tapping the pilot hole caused alterations of bone tissue microstructure around the implant, when compared to alterations produced by insertion of the screw, without tapping or pilot hole. The evaluation of the contact between bone and screw was the parameter that presented statistical difference in comparison between the insertion of the implant with and without tapping. CONCLUSION: in comparison with the pilot hole, all the analyzed parameters presented statistical difference.
- Published
- 2009
- Full Text
- View/download PDF
42. Correlação entre o número de parafusos e o percentual de correção no tratamento cirúrgico da escoliose neuromuscular Correlación entre el número de tornillos y el porcentual de corrección en el tratamiento quirúrgico de la escoliosis neuromuscular Correlation between number of screw and curve correction in the treatment of neuromuscular scoliosis
- Author
-
Murilo Tavares Daher, Paulo Tadeu Maia Cavali, Marcus Alexandre Mello Santo, Alexander Junqueira Rossato, Mauricio Antonelli Lehoczki, and Élcio Landim
- Subjects
Columna vertebral ,Escoliosis ,Fusión vertebral ,Tornillos óseos ,Enfermedades neuromusculares ,Resultado del tratamiento ,Coluna vertebral ,Escoliose ,Fusão vertebral ,Parafusos ósseos ,Doenças neuromusculares ,Resultado de tratamento ,Spine ,Scoliosis ,Spinal fusion ,Bone screws ,Neuromuscular diseases ,Treatment outcome ,Orthopedic surgery ,RD701-811 ,Diseases of the musculoskeletal system ,RC925-935 - Abstract
OBJETIVO: avaliar se existe relação entre o número de parafusos pediculares (densidade de parafusos) e o percentual de correção da curva principal no tratamento cirúrgico das escolioses neuromusculares. MÉTODOS: foram avaliados, retrospectivamente, 55 pacientes portadores de escoliose neuromuscular submetidos ao tratamento cirúrgico por meio de artrodese exclusivamente pela via posterior. Foram analisados o valor da curva pré-operatória, o percentual de correção e o valor da curva pós-operatória nas radiografias no pré-operatório e no pós-operatório imediato. Foi calculada a densidade de parafuso (número de parafusos por pedículo na área correspondente à curva principal) e avaliada a sua relação com o percentual de correção pela análise de correlação de Spearman. RESULTADOS: dos 55 pacientes, 28 (51%) eram do sexo feminino e 27 (49%) do masculino, com média de idade de 16,04 anos (dp=4,45). A doença de base mais frequente foi a paralisia cerebral. O valor da escoliose pré-operatória foi, em média, de 81,96º (dp=25,49) e da escoliose residual de 33,82º (dp=19,02), com percentual de correção de 60,28% (dp=15,89). Houve uma relação positiva (r=0,266) e estatisticamente significante entre a densidade de parafusos e a correção da deformidade (p=0,045). CONCLUSÕES: no tratamento cirúrgico das deformidades neuromusculares existe uma relação positiva entre o maior número de parafusos dentro da área da curva principal e o percentual de correção.OBJETIVO: evaluar si existe una relación entre el número de tornillos pediculares (densidad de tornillos) y el porcentual de corrección de la curva principal en el tratamiento quirúrgico de la escoliosis neuromuscular. MÉTODOS: fueron evaluados, retrospectivamente, 55 pacientes portadores de la escoliosis neuromuscular sometidos al tratamiento quirúrgico por medio de la artrodesis, exclusivamente por la vía posterior. Fueron analizados el valor de la curva preoperatoria, el porcentual de corrección y el valor de la curva postoperatoria en las radiografías pre y postoperatoria inmediata. Se calculó la densidad de tornillos (número de tornillos por pedículo en el área correspondiente a la curva principal) y se evaluó su relación con el porcentaje de corrección, por medio del análisis de corrección de Spearman. RESULTADOS: de los 55 pacientes, 28 (51%) eran del sexo femenino y 27 (49%) del masculino, con promedio de edad de 16.04 años (dp=4.45). La patología de base más común fue la parálisis cerebral. El valor de la escoliosis preoperatoria fue en promedio de 81.96º (dp=25.49) y de la escoliosis residual de 33.82º (dp=19.02), con porcentual de corrección de 60.28% (dp=15.89). Hubo una relación positiva (r=0.266) y estadísticamente significativa entre la densidad de los tornillos y la corrección de la deformidad (p=0.045). CONCLUSIONES: en el tratamiento quirúrgico de las deformidades neuromusculares, hay una relación positiva entre el mayor número de tornillos dentro del área de la curva principal y el porcentual de corrección.OBJECTIVE: to investigate if the number of pedicular screw (screw density) within the major curve correlates with the curve correction in the surgical treatment of neuromuscular scoliosis. METHODS: a total of 55 patients with neuromuscular scoliosis that were exclusively submitted to posterior spinal fusion with pedicular screw constructs were retrospectively investigated. Data included major curve measurements assessed on pre and immediate postoperative radiographs, and the percentage of curve correction. The screw density (number of screw within the major curve relative to the number of available implant sites) was calculated; its relationship with the percentage of the curve correction was evaluated by the Spearman's rank correlation coefficient. RESULTS: twenty-eight (51%) females and 27 (48%) males were analyzed, with mean age of 16.04 years (sd=4.45). The commonest base pathology was the cerebral palsy. The preoperative Cobb angle was 81.96º (sd=25.49) and postoperative Cobb angle was 33.82º, (sd=19.02), with averaged curve correction of 60.28% (sd=15.89). There was a significant correlation between screw density and curve correction (r=0.266; p=0.045). CONCLUSIONS: major curve correction correlates positively with the number of pedicular screw within the curve in the surgical treatment of neuromuscular scoliosis.
- Published
- 2009
- Full Text
- View/download PDF
43. Comparação do poder de correção do instrumental de Luque-Galveston e do parafuso pedicular no tratamento cirúrgico da escoliose neuromuscular Comparación del poder de corrección del instrumental de Luque-Galveston y del tornillo pedicular en el tratamiento quirúrgico de la escoliosis neuromuscular Comparison between deformity correction of Luque-Galveston instrumentation and pedicle screw fixation in the surgical treatment of neuromuscular scoliosis
- Author
-
Murilo Tavares Daher, Paulo Tadeu Maia Cavali, Marcus Alexandre Mello Santo, Alexander Junqueira Rossato, Mauricio Antonelli Lehoczki, and Élcio Landim
- Subjects
Columna vertebral ,Escoliosis ,Fusión vertebral ,Tornillos óseos ,Enfermedades neuromusculares ,Resultado del tratamiento ,Coluna vertebral ,Escoliose ,Fusão vertebral ,Parafusos ósseos ,Doenças neuromusculares ,Resultado de tratamento ,Spine ,Scoliosis ,Spinal fusion ,Bone screws ,Neuromuscular diseases ,Treatment outcome ,Orthopedic surgery ,RD701-811 ,Diseases of the musculoskeletal system ,RC925-935 - Abstract
OBJETIVO: avaliar o poder de correção do parafuso pedicular em comparação ao sistema de Luque-Galveston no tratamento cirúrgico da escoliose neuromuscular. MÉTODOS: foram avaliados 74 pacientes submetidos à artrodese exclusivamente pela via posterior, estendendo-se da região torácica alta ao sacro. Vinte e quatro pacientes foram submetidos à fixação com sistema de Luque-Galveston (Grupo 1) e 50, com parafusos pediculares (Grupo 2). Foram avaliadas as radiografias pré-operatórias, em tração e no pós-operatório imediato e mediu-se o valor da curva principal do período pré-operatório (Cobb pré), na tração (Cobb tração), e no pós-operatório (Cobb pós), e calculou-se a flexibilidade da curva e a correção final. Também foi calculado o Índice de Cincinnati, que leva em consideração a correção final e a flexibilidade (Cincinnati = Correção/Flexibilidade). Os mesmos parâmetros foram calculados para a obliquidade pélvica (OP): OP pré, OP tração, OP pós, Flexibilidade OP, Correção OP e Índice de Cincinnati para OP. RESULTADOS: a média da idade dos pacientes do Grupo 1 foi de 12,24 anos e do Grupo 2, de 16,13 anos (p=0,001). No Grupo 1, a principal doença foi a amiotrofia espinhal (38%) e no Grupo 2, a paralisia cerebral (62%). O ângulo de Cobb pré foi de 76,67º para o Grupo 1 e 85,54º para o Grupo 2. A flexibilidade foi de 45,32% para o Grupo 1 e 39,47% para o Grupo 2. A Correção foi de 63,07% para o Grupo 1 e 59,80% para o Grupo 2. O índice de Cincinnati para o Grupo 1 foi de 1,44 e de 1,71 para o Grupo 2. Quanto à OP, tivemos OP pré de 20,71º para o Grupo 1 e 26,60º para o Grupo 2. A Flexibilidade OP foi de 73,61% para o Grupo 1 e 56,54% para o Grupo 2 (p=0,047). A Correção OP foi de 73,47% para o Grupo 1 e de 72,11% para o Grupo 2. O Índice de Cincinnati da OP foi de 1,09 e 1,49, respectivamente para os Grupos 1 e 2 (p=0,045). CONCLUSÕES: a instrumentação com parafusos pediculares mostrou correção da escoliose semelhante à fixação com Luque-Galveston e maior poder de correção da obliquidade pélvica no tratamento das deformidades neuromuscluares.OBJETIVO: evaluar el poder de corrección del tornillo pedicular comparado al sistema de Luque-Galveston en el tratamiento quirúrgico de la escoliosis neuromuscular. MÉTODOS: fueron evaluados 74 pacientes sometidos a la artrodesis exclusivamente por la vía posterior, extendiéndose de la región torácica alta a la sacra. De estos pacientes, 24 fueron sometidos a la fijación con sistema de Luque-Galveston (Grupo 1) y 50 con tornillos pediculares (Grupo 2). Fueron evaluadas las radiografías preoperatorias, en tracción y en el postoperatorio inmediato, además de medido el valor de la curva principal preoperatoria (Cobb pre), en tracción (Cobb tracción) y en el postoperatorio (Cobb post). También fue calculada la flexibilidad de la curva y la corrección final. Fue calculado el índice de Cincinnati que lleva en consideración la corrección final y la flexibilidad (Cincinnati=corrección/flexibilidad). Los mismos parámetros fueron calculados para la oblicuidad pélvica (OP): OP pre, OP tracción, OP post, flexibilidad OP, corrección OP e índice de Cincinnati para OP. RESULTADOS: el promedio de edad de los pacientes del Grupo 1 fue de 12.24 años y del Grupo 2 de 16.13 años (p=0.001). En el Grupo 1, la principal patología fue la amiotrofia espinal (38%) y en el Grupo 2, la parálisis cerebral (62%). O Cobb pre fue de 76.67º para el Grupo 1 y 85.54º para el Grupo 2. La flexibilidad fue de 45.32% para el Grupo 1 y 39.47% para el Grupo 2. La corrección fue de 63.07% para el Grupo 1 y 59.80% para el Grupo 2. El índice de Cincinnati para el Grupo 1 fue de 1.44 y de 1.71 para el Grupo 2. Según el OP, tuvimos OP pre de 20.71º para el Grupo 1 y 26.60º para el Grupo 2. La flexibilidad OP fue de 73.61% para el Grupo 1 y 56.54% para el Grupo 2 (p=0.047). La corrección OP fue de 73.47% para el Grupo 1 y 72.11% para el Grupo 2. El índice de Cincinnati de la OP fue de 1.09 y 1.49, respectivamente para los Grupos 1 y 2 (p=0.045). CONCLUSIONES: la instrumentación con tornillos pediculares mostró corrección de la escoliosis semejante a la fijación con Luque-Galveston y mayor poder de corrección de la oblicuidad pélvica en el tratamiento de las deformidades neuromusculares.OBJETIVE: to compare the correction of the major curve and pelvic obliquity using Luque-Galveston instrumentation and pedicle screw constructs in the treatment of neuromuscular scoliosis. METHODS: seventy-four patients treated by fusion posterior to the sacrum were investigated using preoperative, traction and postoperative radiographs. Twenty-four cases were submitted to Luque-Galveston instrumentation (Group 1) and fifty were submitted to pedicle screw fixation (Group 2). Radiographic parameters were: major curve angle in the preoperative (Cobb preop), traction (Cobb traction), and postoperative films (Cobb postop), flexibility, final correction, and the Cincinnati Index, which correlates final correction and flexibility (Cincinnati = Correctioln / Flexibility). The same parameters were analyzed for pelvic obliquity (PO): PO preop, PO traction, PO postop, Flexibility PO, Correction PO, and Cincinnati Index for PO. RESULTS: mean age in the Group 1 was 12.24 years and 16.13 years in the Group 2 (p=0.001). The commonest disease in Group 1 was spinal muscular atrophy (38%) and in Group 2, cerebral palsy (62%). The mean major curve angle was 76.67º in Group 1 and 85.54º in Group 2. Flexibility was 45.32% in Group 1 and 39.47% in Group 2. Postoperative correction was 63.07% in Group 1 and 59.8% in Group 2. Cincinnati Index was 1.44 in the Group 1 and 1.77 in the Group 2. Mean PO preop was 20.71º in Group 1 and 26.60º in Group 2. PO Flexibility was 73.61% in Group 1 and 56.54% in Group 2 (p=0.047). PO Correction was 73.47% in Group 1 and 72.11% in Group 2. Cincinnati Index for PO was 1.09 in Group 1 and 1.49 in Group 2 (p=0.045). CONCLUSIONS: postoperative major curve correction was similar with pedicle screws and Luque-Galveston instrumentation, but pelvic obliquity correction was greater when pedicle screw was used in the surgical treatment of neuromuscular scoliosis.
- Published
- 2009
- Full Text
- View/download PDF
44. Anatomic considerations for C2 pedicle screw placement: the use of computerized tomography measurements Consideraciones anatómicas de la cocalización de los tornillos pediculares en C2: uitlización de las medidas de la tomografia computadorizada Considerações anatômicas sobre a localização dos parafusos pediculares em C2: utilização das medidas da tomografia computadorizada
- Author
-
Adebukoa Onibokun, Simona Bistazzoni, Marco Sassi, and Larry T. Khoo
- Subjects
Vértebras cervicales ,Tomografía computarizada por rayos X ,Tornillos óseos ,Vértebras cervicais ,Tomografia computadorizada por raios-X ,Parafusos ósseos ,Cervical vertebrae ,Tomography, X-ray computed ,Bone screws ,Orthopedic surgery ,RD701-811 ,Diseases of the musculoskeletal system ,RC925-935 - Abstract
OBJECTIVE: more detailed anatomical knowledge of the C2 pedicle is required to optimize and minimize the risk of screw placement. The aim of this study was to evaluate the linear and angular dimensions of the true C2 pedicle using axial CT. METHODS: ninety three patients (47 males, 46 females mean age 48 years) who had cervical spinal CT imaging performed were evaluated for this study. Axial images of the C2 pedicle were selected and the following pedicle parameters were determined: pedicle width (PW, the mediolateral diameter of the pedicle isthmus, perpendicular to the pedicle axis) and pedicle transverse angle (PTA, that is, the angle between the pedicle axis and the midline of the vertebral body). RESULTS: the overall mean pedicle width was 5.8 1.2mm. The mean pedicle width in males (6.01.3mm) was greater than that in the female subjects (5.6 1.1mm). This difference was not found to be statistically significant (p=.6790). The overall mean pedicle transverse angle was 43.93.9 degrees. The mean PTA in males was 43.23.8 degrees, while that in females was 44.73.7 degrees. CONCLUSION: preoperative planning is absolutely mandatory, particularly in determining not only screw trajectory, but in analyzing individual patient anatomy and reception to a C2 pedicle screw.OBJETIVO: el conocimiento detallado de las características anatómicas del pedículo de C2 es necesario para minimizar los riesgos relacionados con la colocación de los tornillos. El objetivo del estudio fue evaluar las medidas lineares y angulares del eje axial verdadero del pedículo de C2 utilizando la tomografía computadorizada. MÉTODOS: fueron utilizadas tomografías computadorizadas axiales de 93 pacientes (47 del sexo masculino y 46 del sexo femenino) con promedio de edad de 48 años. Las imágenes axiales del pedículo de C2 fueron seleccionadas para el estudio y los parámetros estudiados fueron: Ancho del pedículo (diámetro mediolateral del istmo del pedículo perpendicular al eje del pedículo) y el ángulo transverso del pedículo (ángulo entre el eje del pedículo y la línea media del cuerpo vertebral). RESULTADOS: el valor promedio del ancho pedicular fue de 5.8 1.2mm. En el sexo masculino el valor promedio del ancho del pedículo (6.0 1.3mm) fue mayor comparado con el sexo femenino (5.6 1.1mm), sin embargo no fue observada una diferencia estadística. El valor promedio del ángulo transverso del pedículo fue de 43.9 3.9 grados, siendo de 43.2 3.8 grados en el sexo masculino y 44.7 3.7 grados en el sexo femenino. CONCLUSIÓN: la proyección y determinación en el periodo preoperatorio de las dimensiones anatómicas del pedículo C2 son importantes para la determinación de la trayectoria y dimensiones del local donde el implante será colocado.OBJETIVO: o conhecimento detalhado das características anatômicas do pedículo de C2 é necessário para minimizar os riscos relacionados com a colocação dos parafusos. O objetivo deste trabalho é avaliar as medidas lineares e angulares do eixo axial verdadeiro do pedículo de C2 utilizando tomografia computadorizada. MÉTODOS: foram utilizadas tomografias computadorizadas axiais de 93 pacientes (47 do sexo masculino e 46 do sexo feminino) com média de idade de 48 anos. As imagens axiais do pedículo de C2 foram selecionadas para o estudo e os parâmetros estudados foram: largura do pedículo (diâmetro mediolateral do istmo do pedículo perpendicular ao eixo do pedículo) e o ângulo tranverso do pedículo (ângulo entre o eixo do pedículo e a linha média do corpo vertebral). RESULTADOS: o valor médio da largura do pedículo foi 5,81,2mm. Nos pacientes de sexo masculino o valor médio da largura do pedículo (6,01,3mm) foi maior que nos pacientes de sexo feminino (5,61,1mm). No entanto, não foi observada diferença estatística. O valor médio do ângulo transverso do pedículo foi de 43,93,9 graus, sendo de 43,23,8 graus no sexo masculino e 44,73,7 graus no sexo feminino. CONCLUSÃO: o planejamento e a determinação no período pré-operatório das dimensões anatômicas do pedículo de C2 são importantes para a determinação da trajetória e dimensões do local onde o implante será colocado.
- Published
- 2009
- Full Text
- View/download PDF
45. Tratamento da espondilólise sintomática com reparo direto pela técnica de Buck modificada Tratamiento de la espondilolisis sintomática con preparo directo por la técnica de Buck modificada Modified Buck's direct repair to simptomatic spondylolysis treatment
- Author
-
Bruno Pinto Coelho Fontes, Maurício Erwin Pühler Resende, Carlos Moreira Rezende, Rodrigo D'Alessandro de Macedo, Luis Olímpio Garcia Pedrosa, Jefferson Soares Leal, and Rogério Lúcio Chaves de Resende
- Subjects
Dolor de la región lumbar ,Espondilólisis ,Procedimientos ortopédicos ,Tornillos óseos ,Dor lombar ,Espondilólise ,Procedimentos ortopédicos ,Parafusos ósseos ,back pain ,Spondylolysis ,Orthopedic procedures ,Bone screws ,Orthopedic surgery ,RD701-811 ,Diseases of the musculoskeletal system ,RC925-935 - Abstract
OBJETIVO: justificar a reconstrução da pars interarticularis pela técnica modificada de Buck como método efetivo no tratamento de lombalgia por espondilólise ou espondilolistese tipo 1, refratárias ao tratamento conservador. MÉTODOS: avaliação retrospectiva de oito pacientes com idade entre 11 e 34 anos, operados e acompanhados no período de outubro de 2004 a maio de 2008 com a técnica de Buck utilizando-se parafusos canulados de titânio. Nenhum paciente foi imobilizado no pós-operatório. Os pacientes foram selecionados após serem submetidos a estudos por imagem utilizando radiografias e ressonância magnética. Também foram avaliados no pós-operatório, segundo os critérios de Henderson e quanto à satisfação com o tratamento, assim como o índice de consolidação. RESULTADOS: sete pacientes foram classificados como excelentes, retornando ao nível de prática esportiva e laboral prévia. Dentre eles, um evoluiu com parestesia transitória, com recuperação completa. A oitava paciente apresentou uma pseudartrose bilateral, mas com bom resultado do ponto de vista clínico. Todos os pacientes ficaram satisfeitos com o resultado. CONCLUSÃO: a reconstrução ístmica com parafusos de titânio atingiu excelentes resultados ao aliar biomecânica estável, dissecção mínima da musculatura, com preservação da anatomia e mobilidade do segmento.OBJETIVO: justificar la reconstrucción de la pars interarticularis por la técnica modificada de Buck como método efectivo en el tratamiento de la lumbalgia por espondilosis o espondilolistesis tipo 1, refractarias al tratamiento conservador. MÉTODOS: evaluación retrospectiva de ocho pacientes con edad entre 11 a 34 años, operados y acompañados en el periodo de Octubre de 2004 hasta Mayo de 2008 con la técnica de Buck usando tornillos canulados de titanio. Ningún paciente fue inmovilizado en el postoperatorio. Los pacientes fueron seleccionados después de ser sometidos a estudios por imagen utilizando radiografías y resonancias magnéticas. También fueron evaluados en el postoperatorio, según los criterios de Henderson y el grado de satisfacción con el tratamiento, así como también el índice de consolidación. RESULTADOS: siete pacientes fueron clasificados como excelentes, retornando al nivel de práctica deportiva y laboral previa. Dentro estos siete pacientes, uno evolucionó con parestesias transitorias, con recuperación completa. La octava paciente presentó una pseudoartrosis bilateral, pero con buen resultado desde el punto de vista clínico. Todos los pacientes quedaron satisfechos con el resultado. CONCLUSIÓN: la reconstrucción ístmica con tornillos de titanio tuvo excelentes resultados al juntar biomecánica estable, disección mínima de la musculatura, con preservación de la anatomía y modalidad del segmento.OBJECTIVE: to justify the modified Buck's technique of pars reconstruction as an effective method to spondylolysis and low grade spondylolisthesis treatment. METHODS: eight patients with ages 11 to 34 years were retrospectively evaluated from October 2004 to may 2008. They were operated with Buck´s technique using titanium canulated screws. Immobilization wasn't used in any patient in post-operative period. All patients were studied with magnetic resonance imaging. All patients were assessed in post-operative period with Henderson's criteria of functional capacity. RESULTS: seven patients were assessed as excellent. They didn´t complain pain and were able to return to former occupation and sportive activities. One patient presented temporary paresthesia and leg weakness, and one patient bilateral pseudoarthrosis that cursed with good grade functional capacity. All patients were satisfied with treatment. CONCLUSION: the isthmic reconstruction using titanium screws allowed excellent results allied with stable biomechanics, minimal injury to back muscles, preservation of anatomy and segmental mobility, and better operated spinal imaging.
- Published
- 2009
- Full Text
- View/download PDF
46. Fixação transpedicular da coluna toraco-lombo-sagrada: análise de 124 parafusos
- Author
-
Eunice Carvalho, Jorge Azevedo, Oliana Tarquini, Luís Silva, Luís Teixeira, Carlos Jardim, and José Garcia Pires
- Subjects
Vértebras lumbares ,Tornillos óseos ,Fusión vertebral ,Orthopedic surgery ,RD701-811 ,Diseases of the musculoskeletal system ,RC925-935 - Abstract
OBJECTIVO: Avaliar a técnica free hand de colocação de parafusos transpediculares na coluna torácica, lombar e sagrada. MÉTODOS: Avaliação clínica e imagiológica (tomografia computorizada) de 25 pacientes (13 mulheres e 12 homens) submetidos a instrumentação vertebral num total de 124 parafusos transpediculares aplicados, utilizando a técnica free hand. Os parafusos foram inseridos de T11 a S1, e a maioria destes foram colocados nos níveis L4, L5 e S1. RESULTADOS: 94% dos parafusos transpediculares estavam correctamente colocados no pedículo. Verificou-se que 6% (7 parafusos) estavam mal colocados e destes apenas dois violavam a cortical inferomedial, um destes apresentava uma perfuração inferior a 2 mm e o outro entre 2 e 4 mm. Nenhum dos pacientes seguidos apresentou complicações associadas ao incorrecto posicionamento dos parafusos. CONCLUSÃO: A técnica free hand é segura na instrumentação da coluna torácica e lombo-sagrada.
- Published
- 2013
- Full Text
- View/download PDF
47. Uso de miniimplantes para mesialización de molares mandibulares en maloclusión Clase II: reporte de caso
- Author
-
Sader, Luis Henrique Braga, Souza, Augusto Cesar Rodrigues de, Santos, Angela Thais Shibata, Cotrin, Paula, Freitas, Karina Maria Salvatore de, and Valarelli, Fabricio Pinelli
- Subjects
Ancoragem ortodôntica ,Bone screws ,Anclaje ortodóntico ,Orthodontic anchorage ,Dentes molares ,Parafusos ósseos ,Molar teeth ,Molares ,Tornillos óseos - Abstract
Adult patients frequently present the absence of mandibular first molars, and the rehabilitation of these spaces is necessary, whether prosthetically or with orthodontic closure. This clinical case reports a patient who presents Class II malocclusion and maxillary crowding concomitant with the absence of mandibular first molars. It was decided to carry out the treatment with extractions of the maxillary first premolars and mesialization through mini-implant anchorage of the mandibular second molars to close the spaces of loss of the mandibular first molars. The results were quite satisfactory. The orthodontic movement did not cause significant side effects, and mini-implants played a fundamental role in preventing a change in the patient's profile. It is concluded that mini-implant anchorage can be effective for the mesialization of mandibular molars with minimal effects on the periodontium and profile. Los pacientes adultos presentan frecuentemente la ausencia de primeros molares inferiores, siendo necesaria la rehabilitación de estos espacios, ya sea protésicamente o con cierre ortodóncico. Este caso clínico presenta un paciente que presenta maloclusión clase II y apiñamiento superior concomitante con ausencia de primeros molares inferiores. Se decidió realizar el tratamiento con extracciones de los primeros premolares superiores y mesialización mediante miniimplante de anclaje de los segundos molares inferiores para cerrar los espacios de pérdida de los primeros molares mandibulares. Los resultados fueron bastante satisfactorios. El movimiento de ortodoncia no provocó efectos secundarios importantes y los miniimplantes jugaron un papel fundamental en la prevención de cambios en el perfil del paciente. Se concluye que el anclaje de miniimplantes puede ser eficaz para la mesialización de molares mandibulares con efectos mínimos sobre el periodonto y el perfil. Pacientes adultos apresentam com determinada frequência a ausência dos primeiros molares inferiores, e a reabilitação destes espaços se faz necessárias sendo de forma protética ou com o fechamento ortodôntico. Este caso clínico traz uma paciente que apresenta má oclusão classe II e apinhamentos superiores concomitante à ausência dos primeiros molares inferiores. Foi decidido realizar o tratamento com extrações dos primeiros pré-molares superiores e mesialização por meio de ancoragem em mini-implantes dos segundos molares inferiores para o fechamento dos espaços das perdas dos primeiros molares inferiores. Os resultados foram bastante satisfatórios. A movimentação ortodôntica não causou efeitos colaterais significativos e os mini-implantes tiveram um papel fundamental para que não houvesse alteração no perfil da paciente. Conclui-se que a ancoragem em mini-implantes pode ser efetiva para a mesialização dos molares inferiores com mínimos efeitos no periodonto e no perfil.
- Published
- 2021
48. Avaliação tomográfica dos pedículos vertebrais no tratamento cirúrgico dos pacientes com escoliose idiopática do adolescente Evaluación de tomografía computarizada de pedículos vertebrales nel tratamiento quirúrgico de escoliosis idiopática del adolescente Computed tomography scan evaluation of vertebral pedicles for surgical treatment of adolescent idiopathic scoliosis
- Author
-
Alceu Gomes Chueire, Fabiano Nogueira, Allan Hiroshi de Araujo Ono, Mauro dos Santos Volpi, and Alceu José Fornari Chueire
- Subjects
Escoliosis ,Tornillos Óseos ,Fusión Espinal ,Escoliose ,Parafusos Ósseos ,Fusão Vertebral ,Scoliosis ,Bone Screws ,Spinal Fusion ,Orthopedic surgery ,RD701-811 ,Diseases of the musculoskeletal system ,RC925-935 - Abstract
OBJETIVO: Determinar através de cortes tomográficos e reconstrução tridimensional a incidência de mal posicionamento de parafusos em pacientes submetidos ao tratamento cirúrgico da Escoliose idiopática do adolescente. MÉTODOS: Foram analisados exames tomográficos de 8 pacientes, tratados cirurgicamente no Hospital de Base de São José do Rio Preto-SP, realizada instrumentação posterior partindo de T2 /T4 a L4/L5 totalizando 164 parafusos. RESULTADOS: 32,9% (n=54) apresentavam posicionamento com risco potencial,ou seja desvio acima de 2 milímetros, sendo 20,1% (n=33) com invasão lateral, 9,1% (n=15) com invasão medial, 3,6 %(n=6) com invasão anterior. Dos parafusos que ofereciam risco potencial a relação com aspecto da curva foi de 46% (n=25) na concavidade, 35% (n=19) na convexidade e 19% (n=10) em vértebras adjacentes a curva. CONCLUSÃO: Os limites de penetração aceitáveis, assim como os métodos de mensuração ainda não foram padronizados, a técnica "free hand' mostrou-se segura, apesar da violação dos pedículos. A tomografia computadorizada pré-operatória, auxilia no planejamento cirúrgico e na redução das complicações.OBJETIVO: Evaluar mediante tomografía computarizada tridimensional de reconstrucción, una mala posición de los tornillos de pedículo en pacientes con escoliosis idiopática del adolescente. MÉTODOS: Se analizó cortes de tomografía computarizada de 8 pacientes sometidos a tratamiento quirúrgico en el Hospital de Base de São José do Rio Preto-SP, que se llevaron a cabo la fusión vertebral posterior de T2/T4 a L4/L5, 164 tornillos se insertaron. RESULTADOS: 32,9% (n = 54) fueron mal colocados que ofrecen riesgo potencial, que se consideraba una desviación de 2 mm, 20,1% (n = 33), la invasión lateral, el 9,1% (n = 15) invasión medial, 3,6 % (n = 6) la invasión anterior. De los tornillos mal colocados el 46% (n = 25) fueron en la concavidad, el 35% (n = 19) en la convexidad y el 19% (n = 10) se curva cerca. CONCLUSIÓN: Los límites aceptables invasión no se determinaron también, y también los métodos de medición no están estandarizados. La técnica "free hand" resultó segura, además de violación pedículo. Pre-Op CT Scan mostró útil en la cirugía de la planificación y evitar complicaciones.OBJECTIVE: To Evaluate by CT scan tridimensional reconstruction, malpositioning of pedicle screws in adolescent idiopathic scoliosis patients. METHODS: It was analyzed CT scan cuts of 8 patients submitted to surgical treatment in Hospital de Base de São José do Rio Preto- SP, which were performed posterior spinal fusion from T2/T4 to L4/L5, 164 screws were inserted. RESULTS: 32,9% (n=54) were malpositioned offering potential risk, which was considered 2mm deviation, 20,1% (n=33) lateral invasion, 9,1% (n=15) medial invasion, 3,6% (n= 6) anterior invasion. From those malpositioned screws 46% (n=25) were in concavity, 35% (n=19) in convexity and 19% (n=10) were nearby curve. CONCLUSION: Acceptable invasion boundaries were not well determined, and also measurements methods are not standardized. The "free hand" technique proved safe, besides pedicle violation. Pre-Op CT Scan showed helpful in surgery planning and avoiding complications.
- Published
- 2012
49. Parafuso de massa lateral do atlas para fixação da coluna cervical superior: resultados cirúrgicos Tornillos de masa lateral del atlas para la fijación de la columna cervical superior: resultados quirúrgicos Lateral mass screws of the atlas for upper cervical spine fixation: surgical results
- Author
-
Enrico Ghizoni, Andrei Fernandes Joaquim, Diogo Valli Andrerle, and Sérgio Raimundo Onofre Cabral
- Subjects
Atlas cervical ,Axis ,Tornillos óseos ,Articulación atlantoaxoidea ,Anatomía ,Áxis ,Parafusos ósseos ,Articulação atlanto-axial ,Anatomia ,Cervical atlas ,Bone screws ,Atlanto-axial joint ,Anatomy ,Orthopedic surgery ,RD701-811 ,Diseases of the musculoskeletal system ,RC925-935 - Abstract
OBJETIVO: Apresentar os resultados cirúrgicos de uma série de casos de estabilização da coluna cervical superior com o uso de parafusos de massa lateral do atlas. MÉTODOS: Avaliação retrospectiva dos resultados cirúrgicos de pacientes submetidos à estabilização da coluna cervical superior com o uso de parafusos de massa lateral do atlas. RESULTADOS: Seis pacientes foram operados durante o período de janeiro de 2009 a abril de 2010, quatro homens e duas mulheres. Não houve morbidade permanente ou morbidade nessa série de casos. A principal causa de instabilidade atlanto-axial foi trauma e houve apenas um caso de fratura patológica do odontoide por metástase de próstata. A fixação do áxis foi obtida com o uso de três diferentes técnicas de parafusos (pars, pedicular e de lâmina), com igual distribuição entre os pacientes. CONCLUSÃO: O uso de parafusos na massa lateral do atlas é uma importante técnica para se obter estabilidade e fusão na coluna cervical superior, e com o conhecimento da anatomia e da técnica cirúrgica, bons resultados podem ser atingidos.OBJETIVOS: presentar los resultados quirúrgicos de una serie de casos de estabilización con el uso de tornillos de masa lateral del atlas. MÉTODOS: evaluación retrospectiva de los resultados quirúrgicos de los pacientes sometidos a estabilización de la columna cervical superior con el uso de tornillos de masa lateral del atlas. RESULTADOS: Seis pacientes operados entre enero 2009 y abril 2010, siendo cuatro hombres y dos mujeres. No hubo mortalidad o morbilidad grave en esta serie. La principal causa de inestabilidad atlantoaxial fue traumática con apenas un caso de fractura patológica del odontoide por una metástasis de tumor de próstata. Fijación del axis fue alcanzada con el uso de tres diferentes técnicas (pars, pedicular, laminar), con dos casos cada una. Conclusión: el uso de tornillos de masa lateral en el atlas es una importante técnica para alcanzar la fusión y la estabilidad de la columna cervical, y con el conocimiento de la anatomía y de la técnica quirúrgica es posible obtenerse excelentes resultados.OBJECTIVE: To present the surgical results of a case series of upper cervical spine stabilization with the use of lateral mass screws of the atlas. METHODS: Retrospective review of the surgical results of patients submitted to upper cervical spine stabilization with the use of lateral mass screws of the atlas. RESULTS: Six patients were operated in the period between January 2009 to April 2010, four men and two women. There was no permanent morbidity or mortality in the presented series. The main cause of atlanto-axial instability was trauma and there was just one case of odontoid pathologic fracture from a prostate metastasis. Axis fixation was achieved with the use of three different screw techniques (pars, pedicle and laminar), with equal distribution among the patients. CONCLUSIONS: The use of lateral mass screws of the atlas is an important technique to achieve fusion and stability of the upper cervical spine and with the knowledge of the anatomy and of the surgical technique good results can be achieved.
- Published
- 2011
- Full Text
- View/download PDF
50. Reducción y osteosíntesis de una fractura-luxación de tobillo.
- Author
-
Truffin Rodriguez, Yaniel, Requeiro Molina, José Julio, and Águila Tejeda, Gerardo
- Abstract
Open reduction and internal fixation of the fracture-dislocation of the ankle with plates, screws and Kirschner wires is a well-defined treatment method. This paper presents the management of a fracture-dislocation of the right ankle in a 33-year-old female patient stabilized by using a one-third tubular plate, screws, and Kirschner wires with tension-band wires. Results were satisfactory. [ABSTRACT FROM AUTHOR]
- Published
- 2015
Catalog
Discovery Service for Jio Institute Digital Library
For full access to our library's resources, please sign in.