38 results on '"Trauzeddel, RF"'
Search Results
2. Paediatric musculoskeletal ultrasound – Examination of the joint capsule shape in healthy children and adolescents
- Author
-
Trauzeddel, R, primary, Windschall, D, additional, Lehmann, H, additional, Nirschl, C, additional, Ganser, G, additional, Palm-Beden, K, additional, Berendes, R, additional, Haller, M, additional, Krumrey-Langkammerer, M, additional, Schoof, P, additional, Nimtz-Talake, A, additional, and Trauzeddel, RF, additional
- Published
- 2016
- Full Text
- View/download PDF
3. Pediatric musculoskeletal ultrasound – age- and sex-related normal B-mode findings of the knee
- Author
-
Windschall, D, primary, Trauzeddel, R, additional, Haller, M, additional, Krumrey-Langkammerer, M, additional, Nimtz-Talaska, A, additional, Berendes, R, additional, Ganser, G, additional, Nirschl, C, additional, Schoof, P, additional, Trauzeddel, RF, additional, Palm-Beden, K, additional, and Lehmann, H, additional
- Published
- 2016
- Full Text
- View/download PDF
4. 1056Stented Bioprostheses And Transcatheter Aortic Valve Implantation Reveal Similar Flow Characteristics Using 4D Flow MRI
- Author
-
Trauzeddel, RF, primary, Gelsinger, C, additional, Butter, C, additional, Barker, A, additional, Markl, M, additional, Schulz-Menger, J, additional, and von Knobelsdorff, F, additional
- Published
- 2013
- Full Text
- View/download PDF
5. Abstracts
- Author
-
Doulaptsis, C, Masci, PG, Goetschalckx, K, Janssens, S, Bogaert, J, Ferreira, VM, Piechnik, SK, DallArmellina, E, Karamitsos, TD, Francis, JM, Ntusi, N, Holloway, C, Choudhury, RP, Kardos, A, Robson, MD, Friedrich, MG, Neubauer, S, Miszalski-Jamka, T, Sokolowska, B, Szczeklik, W, Karwat, K, Miszalski-Jamka, K, Belzak, K, Malek, L, Mazur, W, Kereiakes, DJ, Jazwiec, P, Musial, J, Pedrotti, P, Masciocco, G, DAngelo, L, Milazzo, A, Quattrocchi, G, Zanotti, F, Frigerio, M, Roghi, A, Rimoldi, O, Kaasalainen, T, Kivistö, S, Holmström, M, Pakarinen, S, Hänninen, H, Sipilä, O, Lauerma, K, Banypersad, S.M, Fontana, M, Maestrini, V, Sado, D.M, Pinney, J, Wechalekar, A.D, Gillmore, J.D, Lachmann, H, Hawkins, P.N, Moon, J.C, Barone-Rochette, G, Pierard, S, Seldrum, S, de Ravensteen, CM, Melchior, J, Maes, F, Pouleur, A-C, Vancraeynest, D, Pasquet, A, Vanoverschelde, J-L, L Gerber, B, Captur, G, Muthurangu, V, Flett, AS, Wilson, R, Barison, A, Anderson, S, Cook, C, Sado, DM, McKenna, WJ, Mohun, TJ, Elliott, PM, Moon, JC, Pepe, A, Meloni, A, Gulino, L, Rossi, G, Paci, C, Spasisno, A, keilberg, P, Restaino, G, Resta, MC, Positano, V, lombardi, M, Reiter, U, Reiter, G, Kovacs, G, Schmidt, A, Olschewski, H, Fuchsjäger, M, Macmillan, A, Dabir, D, Rogers, T, Monaghan, M, Nagel, E, Puntmann, V, Semaan, E, Spottiswoode, B, Freed, B, Carr, M, Wasielewski, M, Fortney-Campione, K, Shah, S, Carr, J, Markl, M, Collins, J, Sung, YM, Hinojar, R, Ucar, EA, Dabir, D, Voigt, T, Gaddum, N, Schaeffter, T, Nagel, E, Puntmann, VO, Dabir, D, Rogers, T, Ucar, EA, Kidambi, A, Plein, S, Gebker, R, Schnackenburg, B, Voigt, T, Schaeffter, T, Nagel, E, Puntmann, VO, McAlindon, E, Bucciarelli-Ducci, C, Sado, D, Maestrini, V, Piechnik, S, Porter, J, Yamamura, J, Fischer, R, Moon, J, Symons, R, Doulaptsis, C, Masci, P.G, Goetschalckx, K, Dymarkowski, S, Janssens, S, Bogaert, J, Yalin, K, Golcuk, E, Ozer, CS, Buyukbayrak, H, Yilmaz, R, Dursun, M, Bilge, AK, Adalet, K, Reinstadler, SJ, Klug, G, Feistritzer, HJ, Mayr, A, Harrasser, B, Krauter, L, Mair, J, Schocke, MF, Pachinger, O, Metzler, B, Rigolli, M, To, A, Edwards, C, Ding, P, Christiansen, J, Rodríguez-Palomares, JF, Ortiz, JT, Bucciarelli, C, Lee, D, Wu, E, Bonow, RO, Karwat, K, Tomala, M, Miszalski-Jamka, K, Licholaj, S, Mazur, W, Kereiakes, DJ, Nessler, J, Zmudka, K, Jazwiec, P, Miszalski-Jamka, T, Peltonen, J, Kaasalainen, T, Kivistö, S, Holmström, M, Lauerma, K, Rutz, T, Meierhofer, C, Martinoff, S, Ewert, P, Hess, J, Stern, H, Fratz, S, Groarke, JD, Waller, AH, Blankstein, R, Kwong, RY, Steigner, M, Alizadeh, Z, Alizadeh, A, Khajali, Z, Mohammadzadeh, A, Kaykhavani, A, Heidarali, M, Singh, A, Bekele, S, Gunarathne, A, Khan, J, Nazir, SN, Steadman, CD, Kanagala, P, Horsfield, MA, McCann, GP, Duncan, RF, Dundon, BK, Nelson, AJ, Williams, K, Carbone, A, Worthley, MI, Zaman, A, Worthley, SG, Monney, P, Piccini, D, Rutz, T, Vincenti, G, Koestner, S, Stuber, M, Schwitter, J, Gripari, P, Maffessanti, F, Pontone, G, Andreini, D, Bertella, E, Mushtaq, S, Caiani, EG, Pepi, M, El ghannudi, S, Nghiem, A, Germain, P, Jeung, M-J, Roy, C, Gangi, A, Nucifora, G, Muser, D, Masci, PG, Barison, A, Piccoli, G, Rebellato, L, Puppato, M, Gasparini, D, Lombardi, M, Proclemer, A, Nucifora, G, Muser, D, Masci, PG, Barison, A, Piccoli, G, Rebellato, L, Puppato, M, Gasparini, D, Lombardi, M, Proclemer, A, Pöyhönen, P, Kivistö, S, Holmströn, M, Hänninen, H, Thorning, C, Bickelhaupt, S, Kampmann, C, Wentz, KU, Widmer, U, Juli, CF, Miszalski-Jamka, K, Klys, J, Glowacki, J, Kijas, M, Miszalski-Jamka, T, Adamczyk, T, Kwiecinski, R, Bogucka-Czapska, J, Ozaist, M, Mazur, W, Kluczewska, E, Kalarus, Z, Kukulski, T, Karakus, G, Marzluf, B, Bonderman, D, Tufaro, C, Pfaffenberger, S, Babyev, J, Maurer, G, Mascherbauer, J, Kockova, R, Tintera, J, Kautznerova, D, Cerna, D, Sedlacek, K, Kryze, L, El-Husseini, W, Sikula, V, Segetova, M, Kautzner, J, Vasconcelos, M, Lebreiro, A, Martins, E, Cardoso, JS, Madureira, AJ, Ramos, I, Maciel, MJ, Florian, A, Ludwig, A, Rösch, S, Sechtem, U, Yilmaz, A, Monmeneu, J.V, López-Lereu, M.P, Bonanad, C, Sanchis, J, Chaustre, F, Merlos, P, Valero, E, Bodí, V, Chorro, F.J, Yalin, K, Golcuk, E, Ozer, CS, Buyukbayrak, H, Yilmaz, R, Dursun, M, Bilge, AK, Adalet, K, Klug, G, Reinstadler, SJ, Feistritzer, HJ, Mayr, A, Riegler, N, Schocke, M, Esterhammer, R, Kremser, C, Pachinger, O, Metzler, B, Siddiqi, N, Cameron, D, Neil, C, Jagpal, B, Singh, S, Schwarz, K, Papadopoulou, S, Frenneaux, MP, Dawson, D, Robbers, LFHJ, Eerenberg, ES, Teunissen, PFA, Jansen, MF, Hollander, MR, Horrevoets, AJG, Knaapen, P, Nijveldt, R, Levi, MM, van Rossum, AC, Niessen, HWM, Marcu, CB, Beek, AM, van Royen, N, Everaars, H, Robbers, LFHJ, Nijveldt, R, Beek, AM, Teunissen, PFA, Hirsch, A, van Royen, N, Zijlstra, F, Piek, JJ, van Rossum, AC, Goitein, O, Grupper, A, Hamdan, A, Eshet, Y, Beigel, R, Medvedofsky, D, Herscovici, R, Konen, E, Hod, H, Matetzky, S, Cadenas, R, Iniesta, AM, Refoyo, E, Antorrena, I, Guzman, G, Cuesta, E, Salvador, O, López, T, Moreno, M, López-Sendon, JL, Alam, SR, Spath, N, Richards, J, Dweck, M, Shah, A, Lang, N, Semple, S, MacGillivray, T, Mckillop, G, Mirsadraee, S, Pessotto, R, Zamvar, V, Newby, DE, Henriksen, P, Reiter, G, Reiter, U, Kovacs, G, Olschewski, H, Fuchsjäger, M, Ahmad, S, Raza, U, Malik, A, Sun, JP, Eisner, R, Mazur, W, ODonnell, R, Positano, V, Meloni, A, Santarelli, MF, Landini, L, Tassi, C, Grimaldi, S, Gulino, L, De Marchi, D, Chiodi, E, Renne, S, Lombardi, M, Pepe, A, Wu, L, Germans, T, Güçlü, A, Allaart, CP, van Rossum, AC, Kalisz, K, Lehenbauer, K, Katz, D, Bi, X, Cordts, M, Guetter, C, Jolly, M-P, Freed, B, Shah, S, Markl, M, Flukiger, J, Carr, J, Collins, J, Osiak, A, Tyrankiewicz, U, Jablonska, M, Jasinski, K, Jochym, PT, Chlopicki), S, Skorka, T, Kalisz, K, Semaan, E, Katz, D, Bi, X, Cordts, M, Guetter, C, Jolly, MP, Freed, B, Flukiger, J, Lee, D, Kansal, P, Shah, S, Markl, M, Carr, J, Collins, J, Groarke, JD, Shah, RV, Waller, AH, Abbasi, SA, Kwong, RY, Blankstein, R, Steigner, M, Chin, CWL, Semple, S, Malley, T, White, A, Prasad, S, Newby, DE, Dweck, M, Pepe, A, Meloni, A, Lai, ME, Vaquer, S, Gulino, L, De Marchi, D, Cuccia, L, Midiri, M, Vallone, A, Positano, V, Lombardi, M, Pedrotti, P, Milazzo, A, Quattrocchi, G, Roghi, A, Rimoldi, O, Barison, A, De Marchi, D, Masci, P, Milanesi, M, Aquaro, GD, Keilberg, P, Positano, V, Lombardi, M, Positano, Vincenzo, Barison, Andrea, Pugliese, Nicola Riccardo, Masci, Piergiorgio, Del Franco, Annamaria, Aquaro, Giovanni Donato, Landini, Luigi, Lombardi, Massimo, Dieringer, MA, Deimling, M, Fuchs, K, Winter, L, Kraus, O, Knobelsdorff-Brenkenhoff, FV, Schulz-Menger, J, Niendorf, T, Hinojar, R, Ucar, EA, DCruz, D, Sangle, S, Dabir, D, Voigt, T, Gaddum, N, Schaeffter, T, Nagel, E, Puntmann, VO, Sung, YM, Pontone, G, Andreini, D, Bertella, E, Mushtaq, S, Gripari, P, Cortinovis, S, Loguercio, M, Baggiano, A, Conte, E, Pepi, M, El ghannudi, S, Hop, O, Germain, P, Jeung, M-J, De Cesare, A, Roy, C, Gangi, A, Barone-Rochette, G, Pierard, S, Seldrum, S, De Meester de Ravensteen, C, Melchior, J, Maes, F, Pouleur, A-C, Vancraeynest, D, Pasquet, A, Vanoverschelde, J-L, L Gerber, B, Bekele, S, Singh, A, Khan, JN, Nazir, SA, Kanagala, P, McCann, GP, Singh, A, Steadman, CD, Bekele, S, Khan, JN, Nazir, SA, Kanagala, P, McCann, GP, Paelinck, BP, Vandendriessche, T, De Bock, D, De Maeyer, C, Parizel, PM, Christiaan, J, Trauzeddel, RF, Gelsinger, C, Butter, C, Barker, A, Markl, M, Schulz-Menger, J, von Knobelsdorff, F, Florian, A, Schäufele, T, Ludwig, A, Rösch, S, Wenzelburger, I, Yilmaz, A, Sechtem, U, López-Lereu, M.P, Bonanad, C, Monmeneu, J.V, Sanchís, J, Estornell, J, Igual, B, Maceira, A, Chorro, F.J, Focardi, M, Cameli, M, Bennati, E, Massoni, A, Solari, M, Carbone, F, Banchi, B, Mondillo, S, Miia, H, Kirsi, L, Helena, H, Tiina, H, Jyri, L, Pauli, P, Sari, K, Schumm, J, Greulich, S, Grün, S, Ong, P, Klingel, K, Kandolf, R, Sechtem, U, Mahrholdt, H, Raimondi, F, Ou, P, Boudjemline, Y, Bajolle, F, Iserin, F, Bonnet, D, Collins, J, Kalisz, K, Benefield, B, Sarnari, R, Katz, D, Bi, X, Cordts, M, Guetter, C, Jolly, M-P, Freed, B, Flukiger, J, Kansal, P, Lee, D, Shah, S, Markl, M, Carr, J, Sokolowska, B, Miszalski-Jamka, T, Szczeklik, W, Karwat, K, Miszalski-Jamka, K, Belzak, K, Mazur, W, Kereiakes, DJ, Jazwiec, P, Musial, J, Silva, G, Almeida, AG, Resende, C, Marques, JS, Silva, D, David, C, Amaro, C, Costa, P, Silva, JAP, Diogo, AN, Tsokolov, AV, Senchilo, VG, Vertelkin, AV, Hoffmann, P, Mykjåland, G, Wangberg, H, Tønnessen, T, Sjaastad, I, Nordsletten, L, Hjørnholm, U, Løset, A, Rostrup, M, Meloni, A, Gulino, L, Keilberg, P, Palazzi, G, Maddaloni, D, Ascioti, C, Missere, M, Salvatori, C, Positano, V, Lombardi, M, Pepe, A, Meloni, A, Filosa, A, Gulino, L, Pulini, S, Salvatori, C, Chiodi, E, Ascioti, C, Keilberg, P, Positano, V, Lombardi, M, Pepe, A, Meloni, A, Gulino, L, Pietrapertosa, A, Izzi, G, De Marchi, D, Valeri, G, Preziosi, P, Positano, V, Lombardi, M, Pepe, A, Meloni, A, Ruffo, GB, Keilberg, P, Gulino, L, Gerardi, C, Sallustio, G, Tudisca, C, Positano, V, Lombardi, M, Pepe, A, Greulich, S, Backes, M, Schumm, J, Grün, S, Sechtem, U, Mahrholdt, H, Dorniak, K, MSc, AS, Szurowska, E, Fijalkowski, M, Rawicz-Zegrzda, D, Dudziak, M, Raczak, G, Hamdan, A, Baker, FA, Klein, M, Di Segni, E, Goitein, O, Fibisch, G, Konen, E, Müller-Bierl, B, Tanaka, K, Buls, N, Fierens, Y, van Cauteren, T, Willekens, I, van Laere, S, Luypaert, R, de Mey, J, Muzzarelli, S, Faragasso, E, Pedrazzini, G, Sürder, D, Pasotti, E, Moccetti, T, Faletra, F, Qayyum, AA, Hasbak, P, Larsson, HB, Mathiasen, AB, Vejlstrup, NG, Kjaer, A, Kastrup, J, Moschetti, K, Favre, D, Pinget, C, Pilz, G, Petersen, S, Wagner, A, Wasserfallen, JB, Schwitter, J, Ghosh Dastidar, A, Cengarle, M, McAlindon, E, Augustine, D, Nightingale, AK, Bucciarelli-Ducci, C, Dandekar, VK, Ertel, AW, Dickens, C, Gonzalez, RC, Farzaneh-Far, A, Ripley, DP, Higgins, D, McDiarmid, AK, Bainbridge, GJ, Uddin, A, Kidambi, A, Herzog, B, Greenwood, JP, Plein, S, Khanji, M, Newton, T, Westwood, M, Sekhri, N, and Petersen, SE
- Abstract
Background-Aims: Early post-infarction pericardial injury is a common finding but its diagnosis remains elusive. Though C-reactive protein (CRP) is considered a marker of myocardial damage, reflecting myocardial inflammation at the infarcted area, we sought to assess the relationship between CRP and pericardial injury depicted by cardiovascular magnetic resonance (CMR) imaging in patients with ST elevation myocardial infarction (MI). Methods and results: 181 MI patients (84% male) were studied with CMR in the first week and at 4 months post-infarction to assess infarct characteristics, left ventricular volumes/function and pericardial injury. The latter was defined as pericardial fluid >4mm and/or enhancement on late gadolinium enhancement CMR. The CRP-value at day 2 (according to previous literature) was used for correlation with CMR and clinical parameters. Pericardial injury was noted in 87 patients, i.e. effusion (n = 30), inflammation (n = 46), both (n = 11). Patients with pericardial injury had significantly higher peak values of cardiac biomarkers (p<0.001) and higher peak CRP-values than patients with normal pericardium (median 13 vs 43 mg/dl, p<0.001). A strong correlation was found between peak CRP-values and a) left venticular ejection fraction and infarct size both at 1 week and 4 months, b) myocardial hemorrhage, microvascular obstruction (MVO) and pericardial injury at 1 week, c) cardiac biomarkers values and time to PCI. However in a multiple regression model only pericardial injury (p = 0.003) and less importantly time to PCI (p = 0.022) were the independent predictors of CRP values. Conclusion: Pericardial damage described by cardiac MRI occurs often after acute ST elevation MI. CRP-values at the acute phase of MI reflect not only inflammation at the infarcted area but even more the inflammation of the surrounding pericardial tissue.
Table 1 Comparison of baseline clinical and biochemical parameters of patients with or without evidence of early post-infarct pericardial damage on CMR Normal Group (n = 94) Pericardial injury group (n = 87) p-value Agem, years 59±11 60±12 0.48 Male, n(%) 83 (88) 69 (79) 0.10 Diabets, n(%) 12 (13) 9 (10) 0.61 Smoker, n(%) 52 (55) 44 (51) 0.52 Hyperlipidemia, n(%) 56 (60) 55 (63) 0.62 BSA m2 2.0 ± 0.2 2.0 ± 0.2 0.20 Time to PCI, min 195 (155 − 274) 223 (160 − 335) 0.20 Troponin I, μ/l 44 (19 − 92) 90 (44 − 149) >0.001 CK-MB, U/L 128 (77 − 216) 250 (143 − 443) >0.001 CRP, mg/dL 13 (7 − 28) 43 (16 − 96) >0.001 Day of peak CRP 2 (1 − 3) 2 (1 − 3) 0.39 Table 2 Significant correlations between CRP Values and corresponding CMR measurements, cardic biomarkers and clinical related parameters Varibles Spearmanscorrelations r p-value CMR parameters 1 week LV EF −0.28 >0,001 Infractsize(%ofLV) 0.40 >0,001 Microvasular obstruction 0.27 >0,001 Hemorrhage 0.33 >0,001 Size of area atrisk 0.31 >0,001 Transmurality 0.30 >0,001 Pericaldial damage 0.43 >0,001 CMR parameters 4 months LVEF −0.43 >0,001 Infarctsize(%ofLV) 0.46 >0,001 Cardiac Biomarkers Peak TnI 0.34 >0,001 Peak CK-MB 0.32 >0,001 Other Time to PCI 0,182 0,007 - Published
- 2013
- Full Text
- View/download PDF
6. Inter-site comparability of 4D flow cardiovascular magnetic resonance measurements in healthy traveling volunteers-a multi-site and multi-magnetic field strength study.
- Author
-
Müller M, Daud E, Langer G, Gröschel J, Viezzer D, Hadler T, Jin N, Giese D, Schmitter S, Schulz-Menger J, and Trauzeddel RF
- Abstract
Background: Time-resolved 3D cine phase-contrast cardiovascular magnetic resonance (4D flow CMR) enables the characterization of blood flow using basic and advanced hemodynamic parameters. However, different confounders, e.g., different field strength, scanner configurations, or sequences, might impact 4D flow CMR measurements. This study aimed to analyze the inter-site reproducibility of 4D flow CMR to determine the influence of said confounders., Methods: A cohort of 19 healthy traveling volunteers underwent 4D flow CMR at four different sites (Sites I-III: 3 T scanner; Site IV: 1.5 T scanner; all Siemens Healthineers, Erlangen, Germany). Two protocols of one 4D flow CMR research sequence were performed, one acquiring velocity vector fields in the thoracic aorta only and one in the entire heart and thoracic aorta combined. Basic and advanced hemodynamic parameters, i.e., forward flow volume (FFV), peak and mean velocities (Vp and Vm), and wall shear stress (3D WSS), at nine different planes across the thoracic aorta (P1-P2 ascending aorta, P3-P5 aortic arch, P6-P9 descending aorta) were analyzed. Based on a second scan at Site I, mean values and tolerance ranges (TOL) were generated for inter-site comparison. Equivalency was assumed when confidence intervals of Sites II-IV lay within such TOL. Additionally, inter- and intra-observer analysis as well as a comparison between the two protocols was performed, using an intraclass correlation coefficient (ICC)., Results: Inter-site comparability showed equivalency in P1 and P2 for FFV, Vp, and Vm at all sites. Non-equivalency was present in various planes of P3-P9 and in P2 for 3D WSS in one protocol. In total, Site IV showed the most disagreements. Protocol comparison yielded excellent (>0.9) ICC in every plane for FFV, good (0.75-0.9) to excellent ICC for Vm and 3D WSS, good to excellent ICC in eight planes for Vp, and moderate (0.5-0.75) ICC in one plane for Vp. Inter- and intra-observer analysis showed excellent agreement for every parameter., Conclusions: Basic and advanced hemodynamic parameters revealed equivalency at different sites and field strength in the ascending aorta, a clinically important region of interest, under a highly controlled environment., Competing Interests: NJ was employed by Siemens Medical Solutions USA, Inc., DG was employed by Siemens Healthcare GmbH, Erlangen, Germany. The remaining authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest., (© 2024 Müller, Daud, Langer, Gröschel, Viezzer, Hadler, Jin, Giese, Schmitter, Schulz-Menger and Trauzeddel.)
- Published
- 2024
- Full Text
- View/download PDF
7. Hypertrophic obstructive cardiomyopathy-left ventricular outflow tract shapes and their hemodynamic influences applying CMR.
- Author
-
Mayr T, Riazy L, Trauzeddel RF, Bassenge JP, Wiesemann S, Blaszczyk E, Prothmann M, Hadler T, Schmitter S, and Schulz-Menger J
- Subjects
- Humans, Female, Middle Aged, Male, Aged, Retrospective Studies, Phantoms, Imaging, Image Interpretation, Computer-Assisted, Blood Flow Velocity, Models, Cardiovascular, Cardiomyopathy, Hypertrophic physiopathology, Cardiomyopathy, Hypertrophic diagnostic imaging, Cardiomyopathy, Hypertrophic complications, Ventricular Outflow Obstruction physiopathology, Ventricular Outflow Obstruction diagnostic imaging, Ventricular Outflow Obstruction etiology, Hemodynamics, Magnetic Resonance Imaging, Cine, Predictive Value of Tests, Ventricular Function, Left
- Abstract
Hypertrophic cardiomyopathy (HCM) is one of the most common genetic cardiac disorders and is characterized by different phenotypes of left ventricular hypertrophy with and without obstruction. The effects of left ventricular outflow tract (LVOT) obstruction based on different anatomies may be hemodynamically relevant and influence therapeutic decision making. Cardiovascular magnetic resonance (CMR) provides anatomical information. We aimed to identify different shapes of LVOT-obstruction using Cardiovascular Magnetic Resonance (CMR). The study consisted of two parts: An in-vivo experiment for shape analysis and in-vitro part for the assessment of its hemodynamic consequences. In-vivo a 3D depiction of the LVOT was created using a 3D multi-slice reconstruction from 2D-slices (full coverage cine stack with 7 slices and a thickness of 5-6 mm with no gap) in 125 consecutive HOCM patients (age = 64.17 +/- 12.655; female n = 42). In-vitro an analysis of the LVOT regarding shape and flow behavior was conducted. For this purpose, 2D and 4D measurements were performed on 3D printed phantoms which were based on the anatomical characteristics of the in-vivo study, retrospectively. The in-vivo study identified three main shapes named K- (28.8%), X- (51.2%) and V-shape (10.4%) and a mixed one (9.6%). By analyzing the in-vitro flow measurements every shape showed an individual flow profile in relation to the maximum velocity in cm/s. Here, the V-shape showed the highest value of velocity (max. 138.87 cm/s). The X-shape was characterized by a similar profile but with lower velocity values (max. 125.39 cm/s), whereas the K-shape had an increase of the velocity without decrease (max. 137.11 cm/s). For the first time three different shapes of LVOT-obstruction could be identified. These variants seem to affect the hemodynamics in HOCM., Competing Interests: Declarations Competing interests The authors have no relevant financial or non-financial interests to disclose., (© 2024. The Author(s).)
- Published
- 2024
- Full Text
- View/download PDF
8. The influence of post-processing software on quantitative results in 4D flow cardiovascular magnetic resonance examinations.
- Author
-
Trauzeddel RF, Müller M, Demir A, Wiesemann S, Daud E, Schmitter S, Viezzer D, Hadler T, and Schulz-Menger J
- Abstract
Background: Several commercially available software packages exist for the analysis of three-dimensional cine phase-contrast cardiovascular magnetic resonance (CMR) with three-directional velocity encoding (four-dimensional (4D) flow CMR). Only sparse data are available on the impact of these different software solutions on quantitative results. We compared two different commercially available and widely used software packages and their impact on the forward flow volume (FFV), peak velocity (PV), and maximum wall shear stress (WSS) per plane., Materials and Methods: 4D flow CMR datasets acquired by 3 Tesla magnetic resonance imaging of 10 healthy volunteers, 13 aortic stenosis patients, and 7 aortic valve replacement patients were retrospectively analyzed for FFV, PV, and WSS using two software packages in six analysis planes along the thoracic aorta. Absolute (AD) and relative differences (RD), intraclass correlation coefficients (ICC), Bland-Altman analysis, and Spearman's correlation analysis were calculated., Results: For the FFV and PV in healthy volunteers, there was good to excellent agreement between both software packages [FFV: ICC = 0.93-0.97, AD: 0.1 ± 5.4 ml (-2.3 ± 2.4 ml), RD: -0.3 ± 8% (-5.7 ± 6.0%); PV: ICC = 0.81-0.99, AD: -0.02 ± 0.02 ml (-0.1 ± 0.1 ml), RD: -1.6 ± 2.1% (-9.3 ± 6.1%)]. In patients, the FFV showed good to excellent agreement [ICC: 0.75-0.91, AD: -1.8 ± 6.5 ml (-8.3 ± 9.9 ml), RD: -2.2 ± 9.2% (-13.8 ± 17.4%)]. In the ascending aorta, PV showed only poor to moderate agreement in patients (plane 2 ICC: 0.33, plane 3 ICC: 0.72), whereas the rest of the thoracic aorta revealed good to excellent agreement [ICC: 0.95-0.98, AD: -0.03 ± 0.07 (-0.1 ± 0.1 m/s), RD: -3.5 ± 7.9% (-7.8 ± 9.9%)]. WSS analysis showed no to poor agreement between both software packages. Global correlation analyses revealed good to very good correlation between FFV and PV and only poor correlation for WSS., Conclusions: There was good to very good agreement for the FFV and PV except for the ascending aorta in patients when comparing PV and no agreement for WSS. Standardization is therefore necessary., Competing Interests: RT received funding from Deutsche Herzstiftung (German Heart foundation) and DZHK (German Centre for Cardiovascular Research). JS-M holds institutional grants of the Charité—Universitätsmedizin Berlin. The group holds research grants from Siemens Healthineers. The remaining authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest., (© 2024 Trauzeddel, Müller, Demir, Wiesemann, Daud, Schmitter, Viezzer, Hadler and Schulz-Menger.)
- Published
- 2024
- Full Text
- View/download PDF
9. Feasibility of Goal-Directed Fluid Therapy in Patients with Transcatheter Aortic Valve Replacement - An Ambispective Analysis.
- Author
-
Trauzeddel RF, Nordine M, Fucini GB, Sander M, Dreger H, Stangl K, Treskatsch S, and Habicher M
- Subjects
- Humans, Adolescent, Retrospective Studies, Prospective Studies, Feasibility Studies, Goals, Fluid Therapy methods, Aortic Valve surgery, Treatment Outcome, Risk Factors, Length of Stay, Transcatheter Aortic Valve Replacement adverse effects, Delirium etiology, Delirium surgery, Aortic Valve Stenosis surgery
- Abstract
Introduction: Goal-directed fluid therapy (GDFT) has been shown to reduce postoperative complications. The feasibility of GDFT in transcatheter aortic valve replacement (TAVR) patients under general anesthesia has not yet been demonstrated. We examined whether GDFT could be applied in patients undergoing TAVR in general anesthesia and its impact on outcomes., Methods: Forty consecutive TAVR patients in the prospective intervention group with GDFT were compared to 40 retrospective TAVR patients without GDFT. Inclusion criteria were age ≥ 18 years, elective TAVR in general anesthesia, no participation in another interventional study. Exclusion criteria were lack of ability to consent study participation, pregnant or nursing patients, emergency procedures, preinterventional decubitus, tissue and/or extremity ischemia, peripheral arterial occlusive disease grade IV, atrial fibrillation or other severe heart rhythm disorder, necessity of usage of intra-aortic balloon pump. Stroke volume and stroke volume variation were determined with uncalibrated pulse contour analysis and optimized according to a predefined algorithm using 250 ml of hydroxyethyl starch., Results: Stroke volume could be increased by applying GDFT. The intervention group received more colloids and fewer crystalloids than control group. Total volume replacement did not differ. The incidence of overall complications as well as intensive care unit and hospital length of stay were comparable between both groups. GDFT was associated with a reduced incidence of delirium. Duration of anesthesia was shorter in the intervention group. Duration of the interventional procedure did not differ., Conclusion: GDFT in the intervention group was associated with a reduced incidence of postinterventional delirium.
- Published
- 2024
- Full Text
- View/download PDF
10. Influence of a chronic beta-blocker therapy on perioperative opioid consumption - a post hoc secondary analysis.
- Author
-
Trauzeddel RF, Rothe LM, Nordine M, Dehé L, Scholtz K, Spies C, Hadzidiakos D, Winterer G, Borchers F, Kruppa J, and Treskatsch S
- Subjects
- Humans, Male, Female, Aged, Morphine, Pain, Postoperative drug therapy, Analgesics, Opioid therapeutic use, Cardiovascular Diseases
- Abstract
Background: Beta-blocker (BB) therapy plays a central role in the treatment of cardiovascular diseases. An increasing number of patients with cardiovascular diseases undergoe noncardiac surgery, where opioids are an integral part of the anesthesiological management. There is evidence to suggest that short-term intravenous BB therapy may influence perioperative opioid requirements due to an assumed cross-talk between G-protein coupled beta-adrenergic and opioid receptors. Whether chronic BB therapy could also have an influence on perioperative opioid requirements is unclear., Methods: A post hoc analysis of prospectively collected data from a multicenter observational (BioCog) study was performed. Inclusion criteria consisted of elderly patients (≥ 65 years) undergoing elective noncardiac surgery as well as total intravenous general anesthesia without the use of regional anesthesia and duration of anesthesia ≥ 60 min. Two groups were defined: patients with and without BB in their regular preopreative medication. The administered opioids were converted to their respective morphine equivalent doses. Multiple regression analysis was performed using the morphine-index to identify independent predictors., Results: A total of 747 patients were included in the BioCog study in the study center Berlin. 106 patients fulfilled the inclusion criteria. Of these, 37 were on chronic BB. The latter were preoperatively significantly more likely to have arterial hypertension (94.6%), chronic renal failure (27%) and hyperlipoproteinemia (51.4%) compared to patients without BB. Both groups did not differ in terms of cumulative perioperative morphine equivalent dose (230.9 (BB group) vs. 214.8 mg (Non-BB group)). Predictive factors for increased morphine-index were older age, male sex, longer duration of anesthesia and surgery of the trunk. In a model with logarithmised morphine index, only gender (female) and duration of anesthesia remained predictive factors., Conclusions: Chronic BB therapy was not associated with a reduced perioperative opioid consumption., Trial Registration: This study was registered at ClinicalTrials.gov ( NCT02265263 ) on the 15.10.2014 with the principal investigator being Univ.-Prof. Dr. med. Claudia Spies., (© 2024. The Author(s).)
- Published
- 2024
- Full Text
- View/download PDF
11. Impact of training data composition on the generalizability of convolutional neural network aortic cross-section segmentation in four-dimensional magnetic resonance flow imaging.
- Author
-
Manini C, Hüllebrand M, Walczak L, Nordmeyer S, Jarmatz L, Kuehne T, Stern H, Meierhofer C, Harloff A, Erley J, Kelle S, Bannas P, Trauzeddel RF, Schulz-Menger J, and Hennemuth A
- Subjects
- Humans, Female, Male, Reproducibility of Results, Middle Aged, Adult, Case-Control Studies, Aged, Datasets as Topic, Hemodynamics, Regional Blood Flow, Blood Flow Velocity, Young Adult, Perfusion Imaging methods, Neural Networks, Computer, Predictive Value of Tests, Aortic Valve diagnostic imaging, Aortic Valve physiopathology, Aortic Valve abnormalities, Deep Learning, Image Interpretation, Computer-Assisted, Aorta diagnostic imaging, Aorta physiopathology, Bicuspid Aortic Valve Disease diagnostic imaging, Bicuspid Aortic Valve Disease physiopathology
- Abstract
Background: Four-dimensional cardiovascular magnetic resonance flow imaging (4D flow CMR) plays an important role in assessing cardiovascular diseases. However, the manual or semi-automatic segmentation of aortic vessel boundaries in 4D flow data introduces variability and limits the reproducibility of aortic hemodynamics visualization and quantitative flow-related parameter computation. This paper explores the potential of deep learning to improve 4D flow CMR segmentation by developing models for automatic segmentation and analyzes the impact of the training data on the generalization of the model across different sites, scanner vendors, sequences, and pathologies., Methods: The study population consists of 260 4D flow CMR datasets, including subjects without known aortic pathology, healthy volunteers, and patients with bicuspid aortic valve (BAV) examined at different hospitals. The dataset was split to train segmentation models on subsets with different representations of characteristics, such as pathology, gender, age, scanner model, vendor, and field strength. An enhanced three-dimensional U-net convolutional neural network (CNN) architecture with residual units was trained for time-resolved two-dimensional aortic cross-sectional segmentation. Model performance was evaluated using Dice score, Hausdorff distance, and average symmetric surface distance on test data, datasets with characteristics not represented in the training set (model-specific), and an overall evaluation set. Standard diagnostic flow parameters were computed and compared with manual segmentation results using Bland-Altman analysis and interclass correlation., Results: The representation of technical factors, such as scanner vendor and field strength, in the training dataset had the strongest influence on the overall segmentation performance. Age had a greater impact than gender. Models solely trained on BAV patients' datasets performed well on datasets of healthy subjects but not vice versa., Conclusion: This study highlights the importance of considering a heterogeneous dataset for the training of widely applicable automatic CNN segmentations in 4D flow CMR, with a particular focus on the inclusion of different pathologies and technical aspects of data acquisition., Competing Interests: Declaration of competing interests Chiara Manini reports financial support was provided by German Research Foundation. Sebastian Kelle reports financial support was provided by German Center for Cardiovascular Disease. Anja Hennemuth reports financial support was provided by German Research Foundation. Titus Kuehne reports financial support was provided by German Research Foundation. Sebastian Kelle reports financial support was provided by German Research Foundation. Andreas Harloff reports financial support was provided by University of Freiburg Faculty of Medicine. Sebastian Kelle reports a relationship with Philips Healthcare that includes funding grants. The other authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper., (Copyright © 2024 The Authors. Published by Elsevier Inc. All rights reserved.)
- Published
- 2024
- Full Text
- View/download PDF
12. Multi-site comparison of parametric T1 and T2 mapping: healthy travelling volunteers in the Berlin research network for cardiovascular magnetic resonance (BER-CMR).
- Author
-
Gröschel J, Trauzeddel RF, Müller M, von Knobelsdorff-Brenkenhoff F, Viezzer D, Hadler T, Blaszczyk E, Daud E, and Schulz-Menger J
- Subjects
- Humans, Berlin, Reproducibility of Results, Predictive Value of Tests, Healthy Volunteers, Magnetic Resonance Spectroscopy, Magnetic Resonance Imaging, Volunteers
- Abstract
Background: Parametric mapping sequences in cardiovascular magnetic resonance (CMR) allow for non-invasive myocardial tissue characterization. However quantitative myocardial mapping is still limited by the need for local reference values. Confounders, such as field strength, vendors and sequences, make intersite comparisons challenging. This exploratory study aims to assess whether multi-site studies that control confounding factors provide first insights whether parametric mapping values are within pre-defined tolerance ranges across scanners and sites., Methods: A cohort of 20 healthy travelling volunteers was prospectively scanned at three sites with a 3 T scanner from the same vendor using the same scanning protocol and acquisition scheme. A Modified Look-Locker inversion recovery sequence (MOLLI) for T1 and a fast low-angle shot sequence (FLASH) for T2 were used. At one site a scan-rescan was performed to assess the intra-scanner reproducibility. All acquired T1- and T2-mappings were analyzed in a core laboratory using the same post-processing approach and software., Results: After exclusion of one volunteer due to an accidentally diagnosed cardiac disease, T1- and T2-maps of 19 volunteers showed no significant differences between the 3 T sites (mean ± SD [95% confidence interval] for global T1 in ms: site I: 1207 ± 32 [1192-1222]; site II: 1207 ± 40 [1184-1225]; site III: 1219 ± 26 [1207-1232]; p = 0.067; for global T2 in ms: site I: 40 ± 2 [39-41]; site II: 40 ± 1 [39-41]; site III 39 ± 2 [39-41]; p = 0.543)., Conclusion: Parametric mapping results displayed initial hints at a sufficient similarity between sites when confounders, such as field strength, vendor diversity, acquisition schemes and post-processing analysis are harmonized. This finding needs to be confirmed in a powered clinical trial. Trial registration ISRCTN14627679 (retrospectively registered)., (© 2023. Society for Cardiovascular Magnetic Resonance.)
- Published
- 2023
- Full Text
- View/download PDF
13. [Risk factors for postoperative hypoxemia during transport to the postanesthesia care unit and influence of transport monitoring : A retrospective propensity score-matched databank analysis].
- Author
-
Haller K, Trauzeddel RF, Treskatsch S, and Berger C
- Subjects
- Humans, Aged, Retrospective Studies, Propensity Score, Risk Factors, Anesthesia, General adverse effects, Hypoxia epidemiology, Respiration Disorders complications
- Abstract
Background: Within a central operating room area, after general anesthesia (GA) patients are at risk of hypoxemia during transport to the postanesthesia care unit (PACU); however, specific risk factors have not been conclusively clarified and uniform recommendations for monitoring vital signs during transport within a central operating room area complex do not exist. The purpose of this retrospective database analysis was to identify risk factors for hypoxemia during this transport and to determine whether the use of transport monitoring (TM) affects the initial value of peripheral venous oxygen saturation (S
p O2 ) in the PACU., Material and Methods: This analysis was performed on a retrospectively extracted dataset of procedures in GA within a central operating room area of a tertiary care hospital from 2015 to 2020. The emergence from GA was conducted in the operating room with subsequent transport to the PACU. The transport distance was between 31 and 72 m. Risk factors for initial hypoxemia in the PACU, defined as peripheral oxygen saturation (Sp O2 ) below 90%, were determined using multivariate analysis. After splitting the dataset into patients without TM (group OM) and with TM (group MM) and propensity score matching, the influence of TM on initial Sp O2 and the Aldrete score after arrival in the PACU were examined., Results and Discussion: From a total of 22,638 complete datasets included in the analysis, 8 risk factors for initial hypoxemia in PACU were identified: age > 65 years, body mass index (BMI) > 30 kg/m2 , chronic obstructive pulmonary disease (COPD), intraoperative airway driving pressure (∆p) > 15 mbar and positive endexpiratory pressure (PEEP) > 5 mbar, intraoperative administration of a long-acting opioids, first preoperative Sp O2 < 97%, and last Sp O2 < 97% measured after emergence from anesthesia before transport. At least 1 risk factor for postoperative hypoxemia was present in 90% of all patients. After propensity score matching, 3362 datasets per group remained for analysis of the influence of TM. Patients transported with TM revealed a higher Sp O2 at PACU arrival (MM 97% [94; 99%], OM 96% [94; 99%], p < 0.001). In a subgroup analysis, this difference between groups remained in the presence of one or more risk factors (MM 97% [94; 99%], OM 96% [94; 98%], p < 0.001, n = 6044) but was not detectable in the absence of risk factors for hypoxemia (MM 97% [97; 100%], OM 99% [97; 100%], p < 0.393, n = 680). Furthermore, the goal of an Aldrete score > 8 at PACU arrival was achieved significantly more often in monitored patients (MM 2830 [83%], OM: 2665 [81%], p = 0.004). Critical hypoxemia (Sp O2 < 90%) at PACU arrival had an overall low occurrence within propensity matched datasets and showed no difference between groups (MM: 161 [5%], OM 150 [5%], p = 0.755). According to these results, consistent use of TM leads to a higher Sp O2 and Aldrete score at PACU arrival, even after a short transport distance within an operating room area. Consequently, it appears to be reasonable to avoid unmonitored transport after general anesthesia, even for short distances., (© 2023. The Author(s).)- Published
- 2023
- Full Text
- View/download PDF
14. Goal-directed fluid therapy using uncalibrated pulse contour analysis and balanced crystalloid solutions during hip revision arthroplasty: a quality implementation project.
- Author
-
Trauzeddel RF, Leitner M, Dehé L, Nordine M, Piper SK, Habicher M, Sander M, Perka C, and Treskatsch S
- Subjects
- Adult, Humans, Prospective Studies, Retrospective Studies, Crystalloid Solutions, Colloids therapeutic use, Arthroplasty, Goals, Fluid Therapy methods
- Abstract
Background: To implement a goal-directed fluid therapy (GDFT) protocol using crystalloids in hip revision arthroplasty surgery within a quality management project at a tertiary hospital using a monocentric, prospective observational study., Methods: Adult patients scheduled for elective hip revision arthroplasty surgery were screened for inclusion in this prospective study. Intraoperatively stroke volume (SV) was optimized within a previously published protocol using uncalibrated pulse contour analysis and balanced crystalloids. Quality of perioperative GDFT was assessed by protocol adherence, SV increase as well as the rate of perioperative complications. Findings were then compared to two different historical groups of a former trial: one receiving GDFT with colloids (prospective colloid group) and one standard fluid therapy (retrospective control group) throughout surgery. Statistical analysis constitutes exploratory data analyses and results are expressed as median with 25th and 75th percentiles, absolute and relative frequencies, and complication rates are further given with 95% confidence intervals for proportions using the normal approximation without continuity correction., Results: Sixty-six patients underwent GDFT using balanced crystalloids and were compared to 130 patients with GDFT using balanced colloids and 130 controls without GDFT fluid resuscitation. There was a comparable increase in SV (crystalloids: 65 (54-74 ml; colloids: 67.5 (60-75.25 ml) and total volume infused (crystalloids: 2575 (2000-4210) ml; colloids: 2435 (1760-3480) ml; and controls: 2210 (1658-3000) ml). Overall perioperative complications rates were similar (42.4% (95%CI 30.3-55.2%) for crystalloids and 49.2% (95%CI 40.4-58.1%) for colloids and lower compared to controls: 66.9% (95%CI 58.1-74.9)). Interestingly, a reduced number of hemorrhagic complications was observed within crystalloids: 30% (95%CI 19.6-42.9); colloids: 43% (95%CI 34.4-52.0); and controls: 62% (95%CI 52.6-69.9). There were no differences in the rate of admission to the post-anesthesia care unit or intensive care unit as well as the length of stay., Conclusions: Perioperative fluid management using a GDFT protocol with crystalloids in hip revision arthroplasty surgery was successfully implemented in daily clinical routine. Perioperative complications rates were reduced compared to a previous management without GDFT and comparable when using colloids., Trial Registration: ClinicalTrials.gov identifier: NCT01753050., (© 2023. The Author(s).)
- Published
- 2023
- Full Text
- View/download PDF
15. Intraoperative Beat-to-Beat Pulse Transit Time (PTT) Monitoring via Non-Invasive Piezoelectric/Piezocapacitive Peripheral Sensors Can Predict Changes in Invasively Acquired Blood Pressure in High-Risk Surgical Patients.
- Author
-
Nordine M, Pille M, Kraemer J, Berger C, Brandhorst P, Kaeferstein P, Kopetsch R, Wessel N, Trauzeddel RF, and Treskatsch S
- Subjects
- Humans, Blood Pressure physiology, Blood Pressure Determination, Pulse Wave Analysis, Arterial Pressure, Monitoring, Intraoperative
- Abstract
Background: Non-invasive tracking of beat-to-beat pulse transit time (PTT) via piezoelectric/piezocapacitive sensors (PES/PCS) may expand perioperative hemodynamic monitoring. This study evaluated the ability for PTT via PES/PCS to correlate with systolic, diastolic, and mean invasive blood pressure (SBP
IBP , DBPIBP , and MAPIBP , respectively) and to detect SBPIBP fluctuations., Methods: PES/PCS and IBP measurements were performed in 20 patients undergoing abdominal, urological, and cardiac surgery. A Pearson's correlation analysis (r) between 1/PTT and IBP was performed. The predictive ability of 1/PTT with changes in SBPIBP was determined by area under the curve (reported as AUC, sensitivity, specificity)., Results: Significant correlations between 1/PTT and SBPIBP were found for PES (r = 0.64) and PCS (r = 0.55) ( p < 0.01), as well as MAPIBP /DBPIBP for PES (r = 0.6/0.55) and PCS (r = 0.5/0.45) ( p < 0.05). A 7% decrease in 1/PTTPES predicted a 30% SBPIBP decrease (0.82, 0.76, 0.76), while a 5.6% increase predicted a 30% SBPIBP increase (0.75, 0.7, 0.68). A 6.6% decrease in 1/PTTPCS detected a 30% SBPIBP decrease (0.81, 0.72, 0.8), while a 4.8% 1/PTTPCS increase detected a 30% SBPIBP increase (0.73, 0.64, 0.68)., Conclusions: Non-invasive beat-to-beat PTT via PES/PCS demonstrated significant correlations with IBP and detected significant changes in SBPIBP . Thus, PES/PCS as a novel sensor technology may augment intraoperative hemodynamic monitoring during major surgery.- Published
- 2023
- Full Text
- View/download PDF
16. Changes of aortic hemodynamics after aortic valve replacement-A four dimensional flow cardiovascular magnetic resonance follow up study.
- Author
-
Wiesemann S, Trauzeddel RF, Musa A, Hickstein R, Mayr T, von Knobelsdorff-Brenkenhoff F, Bollache E, Markl M, and Schulz-Menger J
- Abstract
Objectives: Non-invasive assessment of aortic hemodynamics using four dimensional (4D) flow magnetic resonance imaging (MRI) provides new information on blood flow patterns and wall shear stress (WSS). Aortic valve stenosis (AS) and/or bicuspid aortic valves (BAV) are associated with altered aortic flow patterns and elevated WSS. Aim of this study was to investigate changes in aortic hemodynamics over time in patients with AS and/or BAV with or without aortic valve replacement., Methods: We rescheduled 20 patients for a second 4D flow MRI examination, whose first examination was at least 3 years prior. A total of 7 patients received an aortic valve replacement between baseline and follow up examination (=operated group = OP group). Aortic flow patterns (helicity/vorticity) were assessed using a semi-quantitative grading approach from 0 to 3, flow volumes were evaluated in 9 planes, WSS in 18 and peak velocity in 3 areas., Results: While most patients had vortical and/or helical flow formations within the aorta, there was no significant change over time. Ascending aortic forward flow volumes were significantly lower in the OP group than in the NOP group at baseline (NOP 69.3 mL ± 14.2 mL vs. OP 55.3 mL ± 1.9 mL p = 0.029). WSS in the outer ascending aorta was significantly higher in the OP group than in the NOP group at baseline (NOP 0.6 ± 0.2 N/m
2 vs. OP 0.8 ± 0.2 N/m2 , p = 0.008). Peak velocity decreased from baseline to follow up in the aortic arch only in the OP group (1.6 ± 0.6 m/s vs. 1.2 ± 0.3 m/s, p = 0.018)., Conclusion: Aortic valve replacement influences aortic hemodynamics. The parameters improve after surgery., Competing Interests: The authors received research support from Siemens Healthineers (JS-M, SW, and MM) and Circle Cardiovascular Imaging (JS-M and SW), research grants from Circle Cardiovascular Imaging (MM) and Cryolife Inc (MM), and performed activities in consulting Circle Cardiovascular Imaging (MM). The remaining authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest., (Copyright © 2023 Wiesemann, Trauzeddel, Musa, Hickstein, Mayr, von Knobelsdorff-Brenkenhoff, Bollache, Markl and Schulz-Menger.)- Published
- 2023
- Full Text
- View/download PDF
17. [Unrecognized postoperative tooth aspiration].
- Author
-
Kreienbühl L, Ocken M, Trauzeddel RF, Grubitzsch H, and Treskatsch S
- Subjects
- Humans, Postoperative Period, Tooth Loss, Respiratory Aspiration
- Published
- 2022
- Full Text
- View/download PDF
18. Different Impacts on the Heart After COVID-19 Infection and Vaccination: Insights From Cardiovascular Magnetic Resonance.
- Author
-
Gröschel J, Bhoyroo Y, Blaszczyk E, Trauzeddel RF, Viezzer D, Saad H, Fenski M, and Schulz-Menger J
- Abstract
Introduction: Myocarditis-like findings after COVID-19 (coronavirus disease 2019) infection and vaccination were reported by applying cardiovascular magnetic resonance (CMR). These results are very heterogenous and dependent on several factors such as hospital admission or outpatient treatment, timing of CMR, and symptomatic load. This retrospective study aimed to identify differences in myocardial damage in patients with persistent symptoms both after COVID-19 infection and vaccine by applying CMR., Materials and Methods: This study entails a retrospective analysis of consecutive patients referred for CMR between August 2020 and November 2021 with persistent symptoms after COVID-19 infection or vaccination. Patients were compared to healthy controls (HC). All patients underwent a CMR examination in a 1.5-T scanner with a scan protocol including: cine imaging for biventricular function and strain assessment using feature tracking, T2 mapping for the quantification of edema, and T1 mapping for diffuse fibrosis and late gadolinium enhancement (LGE) for the detection and quantification of focal fibrosis. Patients were divided into a subacute COVID-19 (sCov) group with symptoms lasting < 12 weeks, post-COVID-19 (pCov) group with symptoms > 12 weeks, and patients after COVID-19 vaccination (CovVac)., Results: A total of 162 patients were recruited of whom 141 were included for analysis. The median age in years (interquartile range (IQR)) of the entire cohort was 45 (37-56) which included 83 women and 58 men. Subgroups were as follows (total patients per subgroup, median age in years (IQR), main gender): 34 sCov, 43 (37-52), 19 women; 63 pCov, 52 (39-58), 43 women; 44 CovVac, 43 (32-56), 23 men; 44 HC (41 (28-52), 24 women). The biventricular function was preserved and revealed no differences between the groups. No active inflammation was detected by T2 mapping. Global T1 values were higher in pCov in comparison with HC (median (IQR) in ms: pCov 1002ms (981-1023) vs. HC 987ms (963-1009; p = 0.005) with other parings revealing no differences. In 49/141 (34.6%) of patients, focal fibrosis was detectable with the majority having a non-ischemic pattern (43/141; 30.4%; patients) with the subgroups after infection having more often a subepicardial pattern compared with CovVac (total (% of group): sCov: 7/34(21%); pCov 13/63(21%); CovVac 2/44(5%); p = 0.04)., Conclusion: Patients after COVID-19 infection showed more focal fibrosis in comparison with patients after COVID-19 vaccination without alterations in the biventricular function., Competing Interests: The authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest., (Copyright © 2022 Gröschel, Bhoyroo, Blaszczyk, Trauzeddel, Viezzer, Saad, Fenski and Schulz-Menger.)
- Published
- 2022
- Full Text
- View/download PDF
19. [Role of cardiovascular magnetic resonance in cardiovascular diagnostics].
- Author
-
Gröschel J, Trauzeddel RF, Blaszczyk E, and Schulz-Menger J
- Subjects
- Diagnostic Techniques, Cardiovascular, Humans, Magnetic Resonance Spectroscopy, Myocardium, Heart diagnostic imaging, Magnetic Resonance Imaging methods
- Abstract
Cardiovascular magnetic resonance (CMR) has become an accepted method for noninvasive imaging in cardiology. As part of a multimodality concept, this method can contribute valuable diagnostic aspects, often even as a first-choice method in a variety of diseases. Currently the availability is still limited, but the increasing time efficiency, technical stability and the growing competence will lead to more guideline-compliant use. The increase of CMR inclusion into guidelines of various societies is mainly based on the unique selling point of CMR, which is noninvasive myocardial tissue differentiation. In addition to efficient ischemia diagnosis, the ability to differentiate active from chronic inflammatory processes as well as the identification of reversible and irreversible damage are some aspects CMR can offer. New developments are sequences which allow for a parametric assessment of myocardial tissue based on T1- and T2-relaxation times. This is especially useful if the exact pathophysiology is unclear, as it is often the case in left ventricular hypertrophy for example. Next to the noninvasive myocardial tissue characterization CMR allows for quantitative hemodynamic assessment of the heart and the related pathologies. Flows as well as gradients can be quantified based on 2D-flow-sequences. New 4D-sequences are aiming to further characterize blood flow in the heart and the great vessels beyond flow volume and gradients. As with any diagnostic method a qualified application is crucial. In recent years, the technique itself has become much more stable and consensus recommendations of the Society for Cardiovascular Magnetic Resonance are available for the main indications, both for the MRI scan procedure and for the evaluation. Appropriate qualifications and certification opportunities are offered both nationally and internationally., Competing Interests: Die Autorinnen/Autoren geben an, dass kein Interessenkonflikt besteht., (Thieme. All rights reserved.)
- Published
- 2022
- Full Text
- View/download PDF
20. Traveling Volunteers: A Multi-Vendor, Multi-Center Study on Reproducibility and Comparability of 4D Flow Derived Aortic Hemodynamics in Cardiovascular Magnetic Resonance.
- Author
-
Demir A, Wiesemann S, Erley J, Schmitter S, Trauzeddel RF, Pieske B, Hansmann J, Kelle S, and Schulz-Menger J
- Subjects
- Adult, Humans, Magnetic Resonance Spectroscopy, Prospective Studies, Reproducibility of Results, Young Adult, Hemodynamics, Magnetic Resonance Imaging
- Abstract
Background: Implementation of four-dimensional flow magnetic resonance (4D Flow MR) in clinical routine requires awareness of confounders., Purpose: To investigate inter-vendor comparability of 4D Flow MR derived aortic hemodynamic parameters, assess scan-rescan repeatability, and intra- and interobserver reproducibility., Study Type: Prospective multicenter study., Population: Fifteen healthy volunteers (age 24.5 ± 5.3 years, 8 females)., Field Strength/sequence: 3 T, vendor-provided and clinically used 4D Flow MR sequences of each site., Assessment: Forward flow volume, peak velocity, average, and maximum wall shear stress (WSS) were assessed via nine planes (P1-P9) throughout the thoracic aorta by a single observer (AD, 2 years of experience). Inter-vendor comparability as well as scan-rescan, intra- and interobserver reproducibility were examined., Statistical Tests: Equivalence was tested setting the 95% confidence interval of intraobserver and scan-rescan difference as the limit of clinical acceptable disagreement. Intraclass correlation coefficient (ICC) and Bland-Altman plots were used for scan-rescan reproducibility and intra- and interobserver agreement. A P-value <0.05 was considered statistically significant. ICCs ≥ 0.75 indicated strong correlation (>0.9: excellent, 0.75-0.9: good)., Results: Ten volunteers finished the complete study successfully. 4D flow derived hemodynamic parameters between scanners of three different vendors are not equivalent exceeding the equivalence range. P3-P9 differed significantly between all three scanners for forward flow (59.1 ± 13.1 mL vs. 68.1 ± 12.0 mL vs. 55.4 ± 13.1 mL), maximum WSS (1842.0 ± 190.5 mPa vs. 1969.5 ± 398.7 mPa vs. 1500.6 ± 247.2 mPa), average WSS (1400.0 ± 149.3 mPa vs. 1322.6 ± 211.8 mPa vs. 1142.0 ± 198.5 mPa), and peak velocity between scanners I vs. III (114.7 ± 12.6 cm/s vs. 101.3 ± 15.6 cm/s). Overall, the plane location at the sinotubular junction (P1) presented most inter-vendor stability (forward: 78.5 ± 15.1 mL vs. 80.3 ± 15.4 mL vs. 79.5 ± 19.9 mL [P = 0.368]; peak: 126.4 ± 16.7 cm/s vs. 119.7 ± 13.6 cm/s vs. 111.2 ± 22.6 cm/s [P = 0.097]). Scan-rescan reproducibility and intra- and interobserver variability were good to excellent (ICC ≥ 0.8) with best agreement for forward flow (ICC ≥ 0.98)., Data Conclusion: The clinical protocol used at three different sites led to differences in hemodynamic parameters assessed by 4D flow., Level of Evidence: 2 TECHNICAL EFFICACY STAGE: 2., (© 2021 The Authors. Journal of Magnetic Resonance Imaging published by Wiley Periodicals LLC on behalf of International Society for Magnetic Resonance in Medicine.)
- Published
- 2022
- Full Text
- View/download PDF
21. [Perioperative optimization using hemodynamically focused echocardiography in high-risk patients-A practice guide].
- Author
-
Trauzeddel RF, Nordine M, Groesdonk HV, Michels G, Pfister R, Reuter DA, Scheeren TWL, Berger C, and Treskatsch S
- Subjects
- Anesthesiologists, Heart, Hemodynamics, Humans, Echocardiography, Echocardiography, Transesophageal
- Abstract
Background: The number of high-risk patients undergoing surgery is steadily increasing. In order to maintain and, if necessary, optimize perioperative hemodynamics as well as the oxygen supply to the organs (DO
2 ) in this patient population, a timely assessment of cardiac function and the underlying pathophysiological causes of hemodynamic instability is essential for the anesthesiologist. A variety of hemodynamic monitoring procedures are available for this purpose; however, due to method-immanent limitations they are often not able to directly identify the underlying cause of cardiovascular impairment., Objective: To present a stepwise algorithm for a perioperative echocardiography-based hemodynamic optimization in noncardiac surgery high-risk patients. In this context, echocardiography on demand according to international guidelines can be performed under certain conditions (hemodynamic instability, nonresponse to hemodynamic treatment) as well as in the context of a planned intraoperative procedure, mostly as a transesophageal echocardiography., Methods and Results: Hemodynamically focused echocardiography as a rapidly available bedside method, enables the timely diagnosis and assessment of cardiac filling obstructions, volume status and volume response, right and left heart function, and the function of the heart valves., Conclusion: Integrating all echocardiographic findings in a differentiated assessment of the patient's cardiovascular function enables a (patho)physiologically oriented and individualized hemodynamic treatment., (© 2021. Springer Medizin Verlag GmbH, ein Teil von Springer Nature.)- Published
- 2021
- Full Text
- View/download PDF
22. High Central Venous Pressure after Cardiac Surgery Might Depict Hemodynamic Deterioration Associated with Increased Morbidity and Mortality.
- Author
-
Schiefenhövel F, Trauzeddel RF, Sander M, Heringlake M, Groesdonk HV, Grubitzsch H, Kruppa J, Berger C, Treskatsch S, and Balzer F
- Abstract
Background: Cardiac surgery patients represent a high-risk cohort in intensive care units (ICUs). Central venous pressure (CVP) measurement seems to remain an integral part in hemodynamic monitoring, especially in cardio-surgical ICUs. However, its value as a prognostic marker for organ failure is still unclear. Therefore, we analyzed postoperative CVP values after adult cardiac surgery in a large cohort with regard to its prognostic value for morbidity and mortality., Methods: All adult patients admitted to our ICUs between 2006 and 2019 after cardiac surgery were eligible for inclusion in the study ( n = 11,198). We calculated the median initial CVP (miCVP) after admission to the ICU, which returned valid values for 9802 patients. An ROC curve analysis for optimal cut-off miCVP to predict ICU mortality was conducted with consecutive patient allocation into a (a) low miCVP (LCVP) group (≤11 mmHg) and (b) high miCVP (HCVP) group (>11 mmHg). We analyzed the impact of high miCVP on morbidity and mortality by propensity score matching (PSM) and logistic regression., Results: ICU mortality was increased in HCVP patients. In addition, patients in the HCVP group required longer mechanical ventilation, had a higher incidence of acute kidney injury, were more frequently treated with renal replacement therapy, and showed a higher risk for postoperative liver dysfunction, parametrized by a postoperative rise of ≥ 10 in MELD Score. Multiple regression analysis confirmed HCVP has an effect on postoperative ICU-mortality and intrahospital mortality, which seems to be independent., Conclusions: A high initial CVP in the early postoperative ICU course after cardiac surgery is associated with worse patient outcome. Whether or not CVP, as a readily and constantly available hemodynamic parameter, should promote clinical efforts regarding diagnostics and/or treatment, warrants further investigations.
- Published
- 2021
- Full Text
- View/download PDF
23. Current Anesthetic Care of Patients Undergoing Transcatheter Aortic Valve Replacement in Europe: Results of an Online Survey.
- Author
-
Trauzeddel RF, Nordine M, Balanika M, Bence J, Bouchez S, Ender J, Erb JM, Fassl J, Fletcher N, Mukherjee C, Prabhu M, van der Maaten J, Wouters P, Guarracino F, and Treskatsch S
- Subjects
- Anesthesia, General, Aortic Valve diagnostic imaging, Aortic Valve surgery, Europe, Humans, Risk Factors, Surveys and Questionnaires, Treatment Outcome, Anesthetics, Aortic Valve Stenosis diagnostic imaging, Aortic Valve Stenosis surgery, Transcatheter Aortic Valve Replacement
- Abstract
Objectives: Transcatheter aortic valve replacement (TAVR) has become an alternative treatment for patients with symptomatic aortic stenosis not eligible for surgical valve replacement due to a high periprocedural risk or comorbidities. However, there are several areas of debate concerning the pre-, intra- and post-procedural management. The standards and management for these topics may vary widely among different institutions and countries in Europe., Design: Structured web-based, anonymized, voluntary survey., Setting: Distribution of the survey via email among members of the European Association of Cardiothoracic Anaesthesiology working in European centers performing TAVR between September and December 2018., Participants: Physicians., Measurements and Main Results: The survey consisted of 25 questions, including inquiries regarding number of TAVR procedures, technical aspects of TAVR, medical specialities present, preoperative evaluation of TAVR candidates, anesthesia regimen, as well as postoperative management. Seventy members participated in the survey. Reporting members mostly performed 151-to-300 TAVR procedures per year. In 90% of the responses, a cardiologist, cardiac surgeon, cardiothoracic anesthesiologist, and perfusionist always were available. Sixty-six percent of the members had a national curriculum for cardiothoracic anesthesia. Among 60% of responders, the decision for TAVR was made preoperatively by an interdisciplinary heart team with a cardiothoracic anesthesiologist, yet in 5 countries an anesthesiologist was not part of the decision-making. General anesthesia was employed in 40% of the responses, monitored anesthesia care in 44%, local anesthesia in 23%, and in 49% all techniques were offered to the patients. In cases of general anesthesia, endotracheal intubation almost always was performed (91%). It was stated that norepinephrine was the vasopressor of choice (63% of centers). Transesophageal echocardiography guiding, whether performed by an anesthesiologist or cardiologist, was used only ≤30%. Postprocedurally, patients were transferred to an intensive care unit by 51.43% of the respondents with a reported nurse-to-patient ratio of 1:2 or 1:3, to a post-anesthesia care unit by 27.14%, to a postoperative recovery room by 11.43%, and to a peripheral ward by 10%., Conclusion: The results indicated that requirements and quality indicators (eg, periprocedural anesthetic management, involvement of the anesthesiologist in the heart team, etc) for TAVR procedures as published within the European guideline are largely, yet still not fully implemented in daily routine. In addition, anesthetic TAVR management also is performed heterogeneously throughout Europe., (Copyright © 2020 Elsevier Inc. All rights reserved.)
- Published
- 2021
- Full Text
- View/download PDF
24. Echocardiographic Evaluation of Right Ventricular (RV) Performance over Time in COVID-19-Associated ARDS-A Prospective Observational Study.
- Author
-
Asgarpur G, Treskatsch S, Angermair S, Danassis M, Nothnagel AM, Toepper C, Trauzeddel RF, Nordine M, Heeschen J, Al-Chehadeh A, Landmesser U, Sander LE, Kurth F, and Berger C
- Abstract
(1) Background: To evaluate time-dependent right ventricular (RV) performance in patients with COVID-19-associated acute respiratory distress syndrome (ARDS) undergoing intensive care (ICU) treatment. (2) Methods: This prospective observational study included 21 ICU patients with COVID-19-associated ARDS in a university hospital in 2020 (first wave). Patients were evaluated by transthoracic echocardiography at an early (EE) and late (LE) stage of disease. Echocardiographic parameters describing RV size and function as well as RV size in correlation to P
a O2 /Fi O2 ratio were assessed in survivors and nonsurvivors. (3) Results: Echocardiographic RV parameters were within normal range and not significantly different between EE and LE. Comparing survivors and nonsurvivors revealed no differences in RV performance at EE. Linear regression analysis did not show a correlation between RV size and Pa O2 /Fi O2 ratio over all measurements. Analysing EE and LE separately showed a significant increase in RV size correlated to a lower Pa O2 /Fi O2 ratio at a later stage of COVID-19 ARDS. (4) Conclusion: The present study reveals neither a severe RV dilatation nor an impairment of systolic RV function during the initial course of COVID-19-associated ARDS. A trend towards an increase in RV size in correlation with ARDS severity in the second week after ICU admission was observed.- Published
- 2021
- Full Text
- View/download PDF
25. Perioperative echocardiography-guided hemodynamic therapy in high-risk patients: a practical expert approach of hemodynamically focused echocardiography.
- Author
-
Trauzeddel RF, Ertmer M, Nordine M, Groesdonk HV, Michels G, Pfister R, Reuter D, Scheeren TWL, Berger C, and Treskatsch S
- Subjects
- Anesthesiologists, Heart, Humans, Monitoring, Physiologic, Echocardiography, Hemodynamics
- Abstract
The number of high-risk patients undergoing surgery is growing. To maintain adequate hemodynamic functioning as well as oxygen delivery to the vital organs (DO
2 ) amongst this patient population, a rapid assessment of cardiac functioning is essential for the anesthesiologist. Pinpointing any underlying cardiovascular pathophysiology can be decisive to guide interventions in the intraoperative setting. Various techniques are available to monitor the hemodynamic status of the patient, however due to intrinsic limitations, many of these methods may not be able to directly identify the underlying cause of cardiovascular impairment. Hemodynamic focused echocardiography, as a rapid diagnostic method, offers an excellent opportunity to examine signs of filling impairment, cardiac preload, myocardial contractility and the function of the heart valves. We thus propose a 6-step-echocardiographic approach to assess high-risk patients in order to improve and maintain perioperative DO2 . The summary of all echocardiographic based findings allows a differentiated assessment of the patient's cardiovascular function and can thus help guide a (patho)physiological-orientated and individualized hemodynamic therapy.- Published
- 2021
- Full Text
- View/download PDF
26. A new score for characterizing the visibility of anatomical structures during ultrasound guided regional anesthesia: a retrospective cohort study.
- Author
-
Birnbaum J, Diederich L, Ertmer M, Balzer F, Hofmann F, Klotz E, Trauzeddel RF, Volk T, Wernecke KD, Wismayer A, Birnbaum M, and Hensel M
- Subjects
- Humans, Retrospective Studies, Ultrasonography, Ultrasonography, Interventional, Anesthesia, Conduction, Nerve Block
- Abstract
Background: To identify anatomical structures using sonography can be challenging, yet it is a basic requirement for effective and safe ultrasound guided nerve blocks. In clinical routine, we find a wide variety in the visibility of anatomical structures. Aim of this study was to evaluate the feasibility of a newly developed visibility score for anatomical structures in ultrasound guided regional anesthesia., Methods: We retrospectively evaluated the blockades from the routine documentation of ultrasound-guided regional anesthesia over an arbitrary period of 15 months at a university hospital with a Visibility Score (VIS) of one (best) to five (worst visibility)., Results: The study analyzed 983 blockades (femoral, saphenous, infragluteal and popliteal sciatic, transversus abdominis plane, interscalene, supraclavicular, axillary and suprascapular blockades). The following VIS were found: 1: 80.6%; 2: 14.0%; 3: 4.0%; 4: 1.2%; 5: 0.2%. The mean Body Mass Index (BMI) was 27.9 kg/m
2 . The best cut-off for poor VIS was a BMI of 28.9 kg/m2 . For infragluteal sciatic nerve block VIS was significantly higher (mean VIS 1.71±1.0) compared to all the other recorded blockades except the supraclavicular block., Conclusions: VIS was feasible in clinical routine. Compared to the other evaluated blocks, the VIS for the infragluteal access to the sciatic nerve was rated worst. VIS is found to be worse in obese patients. Further research is needed to evaluate VIS and its suitability for specific questions as for instance anesthetists' learning curves, comparison of different patient populations, ultrasound devices or different nerve blocks.- Published
- 2020
- Full Text
- View/download PDF
27. Correction to: Age dependent ultrasound B-mode findings of the elbow joint in healthy children and adolescents.
- Author
-
Trauzeddel R, Lehmann HW, Trauzeddel RF, Haller M, Palm-Beden K, Ganser G, Berendes R, Nirschl C, Nimtz-Talaska A, Krumrey-Langkammerer M, Schoof P, and Windschall D
- Abstract
The Second author's name was incorrectly published in the original article. The correct name is Hartwig Wilhelm Lehmann.
- Published
- 2019
- Full Text
- View/download PDF
28. Age dependent ultrasound B-mode findings of the elbow joint in healthy children and adolescents.
- Author
-
Trauzeddel R, Lehman H, Trauzeddel RF, Haller M, Palm-Beden K, Ganser G, Berendes R, Nirschl C, Nimtz-Talaska A, Krumrey-Langkammerer M, Schoof P, and Windschall D
- Subjects
- Adolescent, Age Factors, Child, Child, Preschool, Female, Healthy Volunteers, Humans, Infant, Male, Reference Values, Adolescent Development, Child Development, Elbow Joint diagnostic imaging, Ultrasonography
- Abstract
Due to maturation of joints, various changes take place, not only in the field of paediatric rheumatology but also in paediatric orthopaedics musculoskeletal ultrasound plays an important role in both the diagnosis and the follow-up of diseases in this field. To differentiate between physiological and pathological findings, the knowledge of reference values of joint structures is indispensable. The objective was to define B-mode ultrasound age- and sex-related reference values for the elbow joint in healthy children and adolescents during maturation. In a cross-sectional, multicentre ultrasound study we examined both sides of the elbow joints of 437 healthy children and adolescents (194 boys/243 girls) being between one and less than 18 years old. The children were classified into six equal age groups and divided according to their gender. We measured the distance between the outer margin of the joint capsule and the bone surface to define the bone-capsule distance (BCD), the thickness of the joint cartilage as well as the thickness of the joint capsule. The bone-capsule junction zone and the shape of the joint capsule were analysed qualitatively. The bone capsule distance and the capsule thickness increased with age. In contrast, the joint cartilage thickness decreased. In most cases the junction zone was peaked. The joint capsule showed mostly a concave shape. Intra- and interobserver reliabilities were good. We propose B-mode ultrasound age- and sex-related reference values for the elbow joint in a large number of healthy children and adolescents for the first time. By applying these standard values to the ultrasound examination of the elbow joint, it may be possible to achieve greater certainty in the diagnosis of pathological processes.
- Published
- 2019
- Full Text
- View/download PDF
29. Local infiltration anaesthesia versus sciatic nerve and adductor canal block for fast-track knee arthroplasty: A randomised controlled clinical trial.
- Author
-
Kastelik J, Fuchs M, Krämer M, Trauzeddel RF, Ertmer M, von Roth P, Perka C, Kirschbaum SM, Tafelski S, and Treskatsch S
- Subjects
- Aged, Anesthetics, Local administration & dosage, Female, Humans, Male, Middle Aged, Pain Measurement, Pain, Postoperative diagnosis, Pain, Postoperative etiology, Sciatic Nerve diagnostic imaging, Sciatic Nerve drug effects, Time Factors, Treatment Outcome, Ultrasonography, Interventional, Anesthesia, Local, Arthroplasty, Replacement, Knee adverse effects, Nerve Block methods, Pain, Postoperative prevention & control, Patient Satisfaction
- Abstract
Background: Local infiltration anaesthesia (LIA) was introduced as an innovative analgesic procedure for enhanced recovery after primary total knee arthroplasty (TKA). However, LIA has never been compared with analgesia based on an adductor canal catheter and a single-shot sciatic nerve block., Objective: To evaluate two analgesic regimens for TKA comparing mobility, postoperative pain and patient satisfaction., Design: Two-group randomised, controlled clinical trial., Setting: Charité-Universitätsmedizin Berlin, Campus Charité Mitte, Germany between April and August 2017., Patients: Adults undergoing primary TKA under general anaesthesia were eligible for study participation. Exclusion criteria were heart insufficiency (New York Heart Association class >2), liver insufficiency (Child Pugh Score >B), evidence of diabetic polyneuropathy, severe obesity (BMI > 40 kg m), chronic opioid therapy for more than 3 months before scheduled surgery and allergy to local anaesthetics., Interventions: Nerve block patients group (n=20) underwent surgery with two ultrasound-guided regional anaesthesia blocks: a single-shot sciatic nerve block with 20 ml of ropivacaine 0.75% combined with an adductor canal block with a catheter placed for less than 4 days with an infusion of ropivacaine 0.2% at a rate of 6 ml h. LIA patients (LIA group, n=20) received LIA of the knee capsule at the end of surgery with 150 ml of ropivacaine 0.2%., Main Outcome Measures: The primary endpoint was postoperative time to patient mobilisation (ability to walk) on the ward., Results: Baseline characteristics were similar in each study group. Patients in both groups were mobilised to walk after TKA in similar time frames (LIA 24.0 h versus nerve block 27.1 h, 95% CI of difference -9.6 to 3.3 h). Maximum postoperative pain scores on exertion were higher in LIA patients with a mean 1.3 of 10 numerical rating scale points (95% CI 0.3 to 2.3, P = 0.010) as were intra-operative opioid requirements (LIA median 107 [IQR 100 to 268] mg versus nerve block median 78 [60 to 98] mg, P < 0.001). Patient satisfaction, postoperative oral morphine-equivalents and resting pain levels were comparable between groups. Anaesthesia induction time was reduced in LIA patients (LIA 10 min versus nerve block 35 min, 95% CI of difference 13 to 38 min, P < 0.001)., Conclusion: Both analgesic regimens allow early mobilisation after TKA with high patient satisfaction. LIA shortened peri-operative time. Further research is required to optimise especially pain control during the later postoperative period with LIA., Clinical Trial Registration: Clinicaltrials.gov identifier NCT03114306.
- Published
- 2019
- Full Text
- View/download PDF
30. Utilization of echocardiography in Intensive Care Units: results of an online survey in Germany.
- Author
-
Balzer F, Trauzeddel RF, Ertmer M, Erb J, Heringlake M, Groesdonk HV, Goepfert M, Reuter DA, Sander M, and Treskatsch S
- Subjects
- Germany, Health Care Surveys, Humans, Intensive Care Units, Internet, Critical Care methods, Echocardiography statistics & numerical data, Emergency Medicine, Practice Patterns, Physicians', Procedures and Techniques Utilization statistics & numerical data
- Abstract
Background: In patients with hemodynamic instability echocardiography has been recommended as the preferred modality to evaluate the underlying pathophysiology. However, due to the fact that recent scientific data on the utilization of echocardiography in German Intensive Care Units (ICU) are scarce, we sought to investigate current practice., Methods: A structured, web-based, anonymized survey was performed from May until July 2015 among members of the German Interdisciplinary Association of Critical Care and Emergency Medicine (DIVI) consisting of 14 questions. Descriptive data analysis was performed., Results: One hundred four intensivists participated in the survey. Two-thirds of participants (66%) used echocardiography regularly for hemodynamic monitoring and stated that it changed the therapy in 26-50% of the cases irrespective of the time performed after ordering the examination. Transthoracic (TTE) were more frequently used than transesophageal (TEE) examinations. Twenty-six percent of the participants held an echocardiography certificate with a formal examination, 27% completed a structured training without an examination and almost half of the questioned ICU personnel (47%) did not complete a comprehensive training., Conclusions: The results of this survey demonstrate a widespread utilization of echocardiography as part of routine diagnostic on frequent number of operative ICUs. However, there might be a lack of structured echocardiographic training especially for anesthesiologists.
- Published
- 2019
- Full Text
- View/download PDF
31. Arthrosonographic Reference Values of the Shoulder Joint in Healthy Children and Adolescents: A Cross-Sectional Multicentre Ultrasound Study.
- Author
-
Trauzeddel R, Windschall D, Trauzeddel RF, Nirschl C, Ganser G, Palm-Beden K, Berendes R, Haller M, Krumrey-Langkammerer M, Nimtz-Talaska A, Schoof P, and Lehmann H
- Subjects
- Adolescent, Child, Child, Preschool, Cross-Sectional Studies, Female, Humans, Infant, Male, Reference Values, Cartilage, Articular diagnostic imaging, Shoulder Joint diagnostic imaging, Ultrasonography methods
- Abstract
Background Defining of gray scale ultrasound standard reference values of the shoulder joint in childhood and adolescence during maturation., Patients: We examined 445 healthy girls and boys between 1 year and 18 years of age. Method A cross-sectional multicentre grey-scale ultrasound study was performed to examine the shoulder joint on both sides. The children were divided according to their gender and were further classified into six age groups, which constituted three-year age ranges, to record anatomical development changes. We measured the capsule-bone distance (BCD) as a representation of the intracapsular cavity, as well as the thickness of the joint capsule and joint cartilage. Values were expressed in mean±standard deviation (SD) and minimum-maximum (min-max). The shape of the joint capsule and capsule-bone junction zone was qualitatively analysed. Results The joint cartilage thickness decreased with increasing age in all joints independently from sex and body side. However, the BCD and the capsule thickness increased with age. There was no intraarticular fluid visible. The joint capsule had a predominantly concave form, whereas the capsule-bone junction was mostly sharp. Discussion This study is the first describing age-related normal values of the intracapsular cavity, joint capsule and cartilage thickness as well as their respective shape in a large cohort of healthy children. Conclusion The findings could be helpful to differentiate between physiological and pathological joint conditions and thereby distinguishing age-related variations from alterations caused by inflammation., Competing Interests: Conflict of interest: All authors have no conflicts of interest regarding this study., (© Georg Thieme Verlag KG Stuttgart · New York.)
- Published
- 2017
- Full Text
- View/download PDF
32. Age-dependent arthrosonographic reference values of the hip joint in healthy children and adolescents - a cross-sectional multicenter ultrasound study.
- Author
-
Trauzeddel RF, Lehmann H, Windschall D, Ganser G, Berendes R, Haller M, Krumrey-Langkammerer M, Palm-Beden K, Nimtz-Talaska A, Nirschl C, Schoof P, and Trauzeddel R
- Subjects
- Adolescent, Age Factors, Cartilage, Articular diagnostic imaging, Child, Child, Preschool, Cross-Sectional Studies, Female, Humans, Infant, Male, Observer Variation, Reference Values, Hip Joint diagnostic imaging, Ultrasonography methods
- Abstract
Background: Musculoskeletal US is a noninvasive imaging method for diagnosing and monitoring inflammatory rheumatic diseases., Objectives: To develop age- and gender-related arthrosonographic reference intervals for the hip joint of healthy children and adolescents., Materials and Methods: In a cross-sectional US study, we examined both hip joints of 445 children and adolescents with an age range of 1 year to 18 years. We measured the distance between the bone surface and the outer margin of the joint capsule to define the bone-capsule distance, the joint capsule and cartilage thickness, and the capsule layer thickness. Reference values were calculated. The shape of the joint capsule and bone-capsule junction zone were analyzed qualitatively. An intraobserver analysis was performed., Results: Bone-capsule distance, capsule thickness and the anterior capsule layer increase with age. In contrast, joint cartilage decreases. The posterior capsule layer exhibited constant thickness across all age groups. The difference between both body sides and gender was collectively less than 0.5 mm. The intraobserver variations were within the calculated reference intervals. The insertion of the capsule to the bone was mostly a peaked one. The capsule shape had a convex or straight configuration in a neutral position and a concave position during outward rotation. The intraobserver analysis revealed good to very good concordance., Conclusion: We propose age- and gender-related reference intervals for the bone-capsule distance, joint capsule and cartilage thickness of the hip.
- Published
- 2017
- Full Text
- View/download PDF
33. Pediatric musculoskeletal ultrasound: age- and sex-related normal B-mode findings of the knee.
- Author
-
Windschall D, Trauzeddel R, Haller M, Krumrey-Langkammerer M, Nimtz-Talaska A, Berendes R, Ganser G, Nirschl C, Schoof P, Trauzeddel RF, Palm-Beden K, and Lehmann H
- Subjects
- Adolescent, Child, Female, Healthy Volunteers, Humans, Male, Reference Values, Bursa, Synovial diagnostic imaging, Cartilage, Articular diagnostic imaging, Knee diagnostic imaging, Knee Joint diagnostic imaging, Patella diagnostic imaging, Ultrasonography methods
- Abstract
Musculoskeletal ultrasound (MSUS) is an important tool for evaluating disease activity, therapeutic progress, and remission status of rheumatic diseases in children. Knowledge of age-related normal findings is essential when interpreting pathological findings such as those seen in juvenile idiopathic arthritis. To evaluate normal findings of the knee joint, we recorded age-related stages of musculoskeletal development in the knee of 435 healthy children between 1 and 18 years of age using high-resolution B-mode MSUS. We determined approximate age- and sex-related norms for the suprapatellar recess size, ossified patella size, and distal femoral intercondylar cartilage thickness. In almost all age-groups, over 64 % of children had visible fluid accumulation in the suprapatellar recess. Significant correlations were found between chronological age and the suprapatellar recess size and ossified patella length (p < 0.05). An age-dependent decrease in intercondylar cartilage thickness of the distal femoral epiphysis was found in children between 10 and 18 years of age. High-resolution B-mode MSUS is an excellent tool for assessing joint and skeletal development in children. Our reference data can be used to discriminate better between normal physiological findings and pathological abnormalities.
- Published
- 2016
- Full Text
- View/download PDF
34. Blood flow characteristics in the ascending aorta after TAVI compared to surgical aortic valve replacement.
- Author
-
Trauzeddel RF, Löbe U, Barker AJ, Gelsinger C, Butter C, Markl M, Schulz-Menger J, and von Knobelsdorff-Brenkenhoff F
- Subjects
- Aged, Aged, 80 and over, Aortic Valve physiopathology, Aortic Valve Stenosis diagnosis, Aortic Valve Stenosis physiopathology, Aortic Valve Stenosis surgery, Bioprosthesis, Blood Flow Velocity, Cardiac Catheterization instrumentation, Female, Heart Valve Prosthesis, Heart Valve Prosthesis Implantation instrumentation, Humans, Magnetic Resonance Angiography, Magnetic Resonance Imaging, Male, Perfusion Imaging methods, Pilot Projects, Prosthesis Design, Regional Blood Flow, Retrospective Studies, Stents, Stress, Mechanical, Treatment Outcome, Aorta physiopathology, Aortic Valve surgery, Aortic Valve Stenosis therapy, Heart Valve Prosthesis Implantation methods
- Abstract
Ascending aortic blood flow characteristics are altered after aortic valve surgery, but the effect of transcatheter aortic valve implantation (TAVI) is unknown. Abnormal flow may be associated with aortic and cardiac remodeling. We analyzed blood flow characteristics in the ascending aorta after TAVI in comparison to conventional stented aortic bioprostheses (AVR) and healthy subjects using time-resolved three-dimensional flow-sensitive cardiovascular magnetic resonance imaging (4D-flow MRI). Seventeen patients with TAVI (Edwards Sapien XT), 12 with AVR and 9 healthy controls underwent 4D-flow MRI of the ascending aorta. Target parameters were: severity of vortical and helical flow pattern (semiquantitative grading from 0 = none to 3 = severe) and the local distribution of systolic wall shear stress (WSSsystole). AVR revealed significantly more extensive vortical and helical flow pattern than TAVI (p = 0.042 and p = 0.002) and controls (p < 0.001 and p = 0.001). TAVI showed significantly more extensive vortical flow than controls (p < 0.001). Both TAVI and AVR revealed marked blood flow eccentricity (64.7 and 66.7%, respectively), whereas controls showed central blood flow (88.9%). TAVI and AVR exhibited an asymmetric distribution of WSSsystole in the mid-ascending aorta with local maxima at the right anterior aortic wall and local minima at the left posterior wall. In contrast, controls showed a symmetric distribution of WSSsystole along the aortic circumference. Blood flow was significantly altered in the ascending aorta after TAVI and AVR. Changes were similar regarding WSSsystole distribution, while TAVI resulted in less helical and vortical blood flow.
- Published
- 2016
- Full Text
- View/download PDF
35. Evaluation of Aortic Blood Flow and Wall Shear Stress in Aortic Stenosis and Its Association With Left Ventricular Remodeling.
- Author
-
von Knobelsdorff-Brenkenhoff F, Karunaharamoorthy A, Trauzeddel RF, Barker AJ, Blaszczyk E, Markl M, and Schulz-Menger J
- Subjects
- Aged, Aortic Valve Stenosis diagnosis, Blood Flow Velocity, Case-Control Studies, Female, Humans, Magnetic Resonance Imaging, Cine, Male, Middle Aged, Models, Cardiovascular, Pilot Projects, Prospective Studies, Regional Blood Flow, Stress, Mechanical, Ventricular Remodeling, Aorta physiopathology, Aortic Valve Stenosis physiopathology, Ventricular Function, Left
- Abstract
Background: Aortic stenosis (AS) leads to variable stress for the left ventricle (LV) and consequently a broad range of LV remodeling. The aim of this study was to describe blood flow patterns in the ascending aorta of patients with AS and determine their association with remodeling., Methods and Results: Thirty-seven patients with AS (14 mild, 8 moderate, 15 severe; age, 63±13 years) and 37 healthy controls (age, 60±10 years) underwent 4-dimensional-flow magnetic resonance imaging. Helical and vortical flow formations and flow eccentricity were assessed in the ascending aorta. Normalized flow displacement from the vessel center and peak systolic wall shear stress in the ascending aorta were quantified. LV remodeling was assessed based on LV mass index and the ratio of LV mass:end-diastolic volume (relative wall mass). Marked helical and vortical flow formation and eccentricity were more prevalent in patients with AS than in healthy subjects, and patients with AS exhibited an asymmetrical and elevated distribution of peak systolic wall shear stress. In AS, aortic orifice area was strongly negatively associated with vortical flow formation (P=0.0274), eccentricity (P=0.0070), and flow displacement (P=0.0021). Bicuspid aortic valve was associated with more intense helical (P=0.0098) and vortical flow formation (P=0.0536), higher flow displacement (P=0.11), and higher peak systolic wall shear stress (P=0.0926). LV mass index and relative wall mass were significantly associated with aortic orifice area (P=0.0611, P=0.0058) and flow displacement (P=0.0058, P=0.0283)., Conclusions: In this pilot study, AS leads to abnormal blood flow pattern and peak systolic wall shear stress in the ascending aorta. In addition to aortic orifice area, normalized flow displacement was significantly associated with LV remodeling., (© 2016 American Heart Association, Inc.)
- Published
- 2016
- Full Text
- View/download PDF
36. Comparison of native high-resolution 3D and contrast-enhanced MR angiography for assessing the thoracic aorta.
- Author
-
von Knobelsdorff-Brenkenhoff F, Gruettner H, Trauzeddel RF, Greiser A, and Schulz-Menger J
- Subjects
- Adult, Aged, Cohort Studies, Contrast Media, Female, Humans, Image Enhancement methods, Male, Middle Aged, Observer Variation, Prospective Studies, Statistics, Nonparametric, Aorta, Thoracic pathology, Aortic Diseases diagnosis, Image Interpretation, Computer-Assisted methods, Imaging, Three-Dimensional methods, Magnetic Resonance Angiography methods
- Abstract
Aims: To omit risks of contrast agent administration, native magnetic resonance angiography (MRA) is desired for assessing the thoracic aorta. The aim was to evaluate a native steady-state free precession (SSFP) three-dimensional (3D) MRA in comparison with contrast-enhanced MRA as the gold standard., Methods and Results: Seventy-six prospective patients with known or suspicion of thoracic aortic disease underwent MRA at 1.5 T using (i) native 3D SSFP MRA with ECG and navigator gating and high isotropic spatial resolution (1.3 × 1.3 × 1.3 mm(3)) and (ii) conventional contrast-enhanced ECG-gated gradient-echo 3D MRA (1.3 × 0.8 × 1.8 mm(3)). Datasets were compared at nine aortic levels regarding image quality (score 0-3: 0 = poor, 3 = excellent) and aortic diameters, as well as observer dependency and final diagnosis. Statistical tests included paired t-test, correlation analysis, and Bland-Altman analysis. Native 3D MRA was acquired successfully in 70 of 76 subjects (mean acquisition time 8.6 ± 2.7 min), while irregular breathing excluded 6 of 76 subjects. Aortic diameters agreed close between both methods at all aortic levels (r = 0.99; bias ± SD -0.12 ± 1.2 mm) with low intra- and inter-observer dependency (intraclass correlation coefficient 0.99). Native MRA studies resulted in the same final diagnosis as the contrast-enhanced MRA. The mean image quality score was superior with native compared with contrast-enhanced MRA (2.4 ± 0.6 vs. 1.6 ± 0.5; P < 0.001)., Conclusion: Accuracy of aortic size measurements, certainty in defining the diagnosis and benefits in image quality at the aortic root, underscore the use of the tested high-resolution native 3D SSFP MRA as an appropriate alternative to contrast-enhanced MRA to assess the thoracic aorta., (Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2014. For permissions please email: journals.permissions@oup.com.)
- Published
- 2014
- Full Text
- View/download PDF
37. Cardiovascular magnetic resonance in adults with previous cardiovascular surgery.
- Author
-
von Knobelsdorff-Brenkenhoff F, Trauzeddel RF, and Schulz-Menger J
- Subjects
- Adult, Cardiovascular Diseases diagnosis, Cardiovascular Diseases surgery, Female, Follow-Up Studies, Heart Valve Diseases diagnosis, Heart Valve Diseases surgery, Humans, Male, Middle Aged, Monitoring, Physiologic methods, Sensitivity and Specificity, Coronary Artery Bypass methods, Heart Valve Prosthesis Implantation methods, Magnetic Resonance Imaging, Cine methods
- Abstract
Cardiovascular magnetic resonance (CMR) is a versatile non-invasive imaging modality that serves a broad spectrum of indications in clinical cardiology and has proven evidence. Most of the numerous applications are appropriate in patients with previous cardiovascular surgery in the same manner as in non-surgical subjects. However, some specifics have to be considered. This review article is intended to provide information about the application of CMR in adults with previous cardiovascular surgery. In particular, the two main scenarios, i.e. following coronary artery bypass surgery and following heart valve surgery, are highlighted. Furthermore, several pictorial descriptions of other potential indications for CMR after cardiovascular surgery are given.
- Published
- 2014
- Full Text
- View/download PDF
38. Blood flow characteristics in the ascending aorta after aortic valve replacement--a pilot study using 4D-flow MRI.
- Author
-
von Knobelsdorff-Brenkenhoff F, Trauzeddel RF, Barker AJ, Gruettner H, Markl M, and Schulz-Menger J
- Subjects
- Adult, Aged, Aged, 80 and over, Aortic Valve physiopathology, Aortic Valve surgery, Bicuspid Aortic Valve Disease, Bioprosthesis, Blood Flow Velocity physiology, Cardiac Imaging Techniques methods, Female, Heart Defects, Congenital physiopathology, Heart Valve Diseases physiopathology, Humans, Magnetic Resonance Imaging methods, Male, Middle Aged, Pilot Projects, Prospective Studies, Stents, Aorta physiology, Aortic Valve physiology, Heart Defects, Congenital surgery, Heart Valve Diseases surgery, Heart Valve Prosthesis, Heart Valve Prosthesis Implantation methods, Hemodynamics physiology
- Abstract
Background: Aortic remodeling after aortic valve replacement (AVR) might be influenced by the postoperative blood flow pattern in the ascending aorta. This pilot study used flow-sensitive four-dimensional magnetic resonance imaging (4D-flow) to describe ascending aortic flow characteristics after various types of AVR., Methods: 4D-flow was acquired in 38 AVR patients (n=9 mechanical, n=8 stentless bioprosthesis, n=14 stented bioprosthesis, n=7 autograft) and 9 healthy controls. Analysis included grading of vortex and helix flow (0-3 point scale), assessment of systolic flow eccentricity (1-3 point scale), and quantification of the segmental distribution of peak systolic wall shear stress (WSS(peak)) in the ascending aorta., Results: Compared to controls, mechanical prostheses showed the most distinct vorticity (2.7±0.5 vs. 0.7±0.7; p<0.001), while stented bioprostheses exhibited most distinct helicity (2.6±0.7 vs. 1.6±0.5; p=0.002). Instead of a physiologic central flow, all stented, stentless and mechanical prostheses showed eccentric flow jets mainly directed towards the right-anterior aortic wall. Stented and stentless prostheses showed an asymmetric distribution of WSS(peak) along the aortic circumference, with significantly increased local WSS(peak) where the flow jet impinged on the aortic wall. Local WSS(peak) was higher in stented (1.4±0.7 N/m(2)) and stentless (1.3±0.7 N/m(2)) compared to autografts (0.6±0.2 N/m(2); p=0.005 and p=0.008) and controls (0.7±0.1 N/m(2); p=0.017 and p=0.027). Autografts exhibited lower absolute WSS(peak) than controls (0.4±0.1 N/m(2) vs. 0.7±0.2 N/m(2); p=0.003)., Conclusions: Flow characteristics in the ascending aorta after AVR are different from native aortic valves and differ between various types of AVR., (Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.)
- Published
- 2014
- Full Text
- View/download PDF
Catalog
Discovery Service for Jio Institute Digital Library
For full access to our library's resources, please sign in.