2,063 results on '"calibración"'
Search Results
2. Simulación numérica en ANSYS Fluent del flujo a través de una compuerta en un canal de laboratorio.
- Author
-
Mogollón-Mogollón, Fernando and Hernández-Avilés, Diana Margarita
- Subjects
- *
NAVIER-Stokes equations , *NONLINEAR differential equations , *NUMERICAL analysis , *CHANNEL flow , *MATHEMATICAL models - Abstract
Flow studies in control structures require the development of nonlinear differential equations that have no analytical solution but can be approximated by applying the finite volume method in mathematical models such as Fluent. This article presents a comparative analysis between a numerical model and a physical model of water flow in a laboratory channel using ANSYS Fluent. The scope of the study includes the development of a 2D model of the laboratory channel with a control section of a sliding flat rectangular gate and the mathematical development of the Navier-Stokes equations to model a biphasic flow of water and air throughout the computational domain, using appropriate boundary conditions. The methodology employed numerical simulation techniques using ANSYS Fluent, applying the finite volume method to solve the flow equations, and experimental techniques through direct measurements taken in the laboratory. The results demonstrate a 95.46% similarity between the mathematical modeling, direct measurements, and analytical calculations. Variables such as discharge coefficient, flow profiles, velocities at different points in the channel, and pressure distribution remained consistent throughout the computational domain. In conclusion, the advantages of the numerical model over the physical model are highlighted, emphasizing its efficiency and cost-effectiveness by allowing easy and simultaneous modifications in problem configurations, turbulence models, and boundary conditions. Additionally, the importance of the numerical model is highlighted by providing more accurate results than direct measurements made on the physical model, especially in turbulent areas and in the interaction of biphasic flow in the channel and gate. Finally, it is important to include a sensitivity analysis and mesh refinement in the mathematical model in such studies to avoid fluctuations near the gate where the section contracts. [ABSTRACT FROM AUTHOR]
- Published
- 2024
- Full Text
- View/download PDF
3. Calibración, un componente subestimado del proceso analítico en el laboratorio clínico.
- Author
-
Sonntag, Oswald and Loh, Tze Ping
- Abstract
Copyright of Advances in Laboratory Medicine / Avances en Medicina de Laboratorio is the property of De Gruyter and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
- Published
- 2024
- Full Text
- View/download PDF
4. Fatigue vulnerability assessment of a steel arch bridge using the probabilistic weibull model and considering its remaining service life under localized corrosion effects.
- Author
-
Núñez Moreno, Federico Alejandro
- Subjects
- *
BRIDGES , *ROADS , *WEIBULL distribution , *CORROSION & anti-corrosives , *STEEL - Abstract
This study attempts to obtain the approximate fatigue vulnerability of a steel arch bridge from the Colombian national road network. It establishes the interaction between the demand and the available capacity through the Weibull probability equation, and an AASHTO remaining-time equation indicated in (FHWA, 2015). However, the available capacity in terms of the S-N curve obtained from available international references was modified to account for the effects of corrosion present in elements and/or joints in the bridge. The load demand was modeled as the controlled action of the fatigue truck reported in AASHTO, which was systematically located on a structural model represented by Shell and Frame type finite elements, which represented the information available in drawings (in the current Colombian bridge management system), and the one obtained from structural survey activities. The structural model was further calibrated by a parametric study on the modulus of elasticity of steel, which included the minimization of the error difference in the vertical deflections of a bridge load test, keeping the magnitude within the expected ranges established in a protocol. Such reports of actual deflections were achieved using distance meters at important points of the bridge. This model allowed for estimating the magnitude of stresses in the structural elements of the bridge, especially in an area of interest for the study where chemical and physical elements of structural deficiency were determined. The results show an inverse relationship between the probability of failure and remaining service life. The effect of corrosion on the remaining capacity and the probability of failure of the structural elements is clear. [ABSTRACT FROM AUTHOR]
- Published
- 2024
- Full Text
- View/download PDF
5. Simulación numérica en ANSYS Fluent del flujo a través de una compuerta en un canal de laboratorio
- Author
-
Fernando Mogollón-Mogollón and Diana Margarita Hernández-Avilés
- Subjects
análisis de flujo en compuertas ,ANSYS Fluent ,calibración ,Canal Gate ,modelado numérico ,comparación experimental y numérica ,Technology ,Engineering (General). Civil engineering (General) ,TA1-2040 - Abstract
Los estudios del flujo en estructuras de control requieren desarrollar ecuaciones diferenciales no lineales que no tienen solución analítica pero que se pueden aproximar a partir de la aplicación del método de volúmenes finitos en los modelos matemáticos como lo es Fluent. El artículo presenta un análisis comparativo entre un modelo numérico y un modelo físico del flujo de agua en un canal de laboratorio utilizando ANSYS Fluent. El alcance del estudio abarca desde el desarrollo de un modelo 2D del canal de laboratorio con sección de control de tipo compuerta rectangular plana deslizante y el desarrollo matemático de las ecuaciones de Navier-Stokes para modelar un flujo bifásico de agua y aire en todo el dominio computacional, utilizando las condiciones de contorno adecuadas. Para la metodología se empleó técnicas de simulación numéricas utilizando ANSYS Fluent, aplicando el método de volúmenes finitos para resolver las ecuaciones de flujo y técnicas experimentales, mediante mediciones directas tomadas en el laboratorio. Los resultados demuestran una similitud del 95.46% entre la modelación matemática, las mediciones directas y los cálculos analíticos. Mientras que las variables como el coeficiente de descarga, los perfiles de flujo, las velocidades en diferentes puntos del canal y la distribución de la presión se mantuvieron consistentes en todo el dominio computacional. En conclusión, se destacan las ventajas del modelo numérico sobre el físico, resaltando su eficiencia y economía al permitir modificaciones en las configuraciones del problema, así como en los modelos de turbulencia y condiciones de contorno de manera fácil y simultánea. Además, se resalta la importancia del modelo numérico al proporcionar resultados más precisos que las mediciones directas hechas en el modelo físico, especialmente en las zonas de turbulencia y en la interacción del flujo bifásico en el canal y en la compuerta. Finalmente, es importante incluir en este tipo de estudios un análisis de sensibilidad y refinamiento del mallado en el modelo matemático para evitar fluctuaciones cerca de la compuerta donde la sección se contrae.
- Published
- 2024
- Full Text
- View/download PDF
6. Implementación en FPGA de la Calibración de un Sistema de Antenas Inteligentes con Superresolución en la Estimación de DOA.
- Author
-
Guerra, Yunior Ibarra, Ramírez, Noslen Rojas, Ramírez Zaldivar, Alexander R., and Violat, Abel Hernández
- Subjects
- *
ADAPTIVE antennas , *COMPUTER hardware description languages , *PDS (Computer system) , *FIELD programmable gate arrays , *DIRECTION of arrival estimation , *PROBLEM solving , *CALIBRATION - Abstract
Receiver channels amplitude and phase calibration in smart antennas is a crucial process to achieve the systems requirement. The implementation of these functions in a programmable device and the procedures for selecting its parameters is not a widely disseminated topic in the specialized literature. This work solves the previous problem by implementing the calibration algorithm in FPGA based on the requirements to guarantee the estimation of the direction of arrival (DOA) with super resolution. The design implemented in Hardware Description Language (HDL) corrects in real time the amplitude and phase errors between channels of the multichannel reception system with low latency and resource consumption. Experimental verification with real signals demonstrates that the errors obtained after calibration are within the expected range and corroborates the effectiveness of the design. [ABSTRACT FROM AUTHOR]
- Published
- 2024
7. CALIBRAÇÃO DE UM SENSOR MPX5700 CONECTADO A UM ARDUÍNO MODELO UNO.
- Author
-
Ferreira Loureiro, Gláucio, Colombo, Alberto, and Ambrósio de Araújo, Daniel Soares
- Subjects
ENERGY conservation ,POWER resources ,OPPORTUNITY costs ,WATER supply ,IRRIGATION - Abstract
Copyright of Revista Foco (Interdisciplinary Studies Journal) is the property of Revista Foco and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
- Published
- 2023
- Full Text
- View/download PDF
8. Desarrollo del Marco Metodológico para la Calibración y Validación del Modelo Hidrodinámico del Sistema de Alcantarillado de la Facultad de Ingeniería y Ciencias Aplicadas
- Author
-
Diego Fernando Paredes Méndez
- Subjects
Sistemas de Drenaje Urbano ,Modelo Hidrodinámico ,monitoreo hidrometeorológico ,calibración ,validación ,PCSWMM ,Industrial engineering. Management engineering ,T55.4-60.8 ,Engineering (General). Civil engineering (General) ,TA1-2040 ,Computer engineering. Computer hardware ,TK7885-7895 - Abstract
Los Sistemas de Drenaje Urbano (SDU) han existido desde épocas del Imperio Babilónico. Su objetivo es preservar y promover la salud pública, bienestar social, protección de inundaciones, contaminación de cuerpos receptores. El crecimiento poblacional en áreas urbanas, cambio climático, envejecimiento de las estructuras, provocan el colapso de esta infraestructura sanitaria e inundaciones. En la presente investigación se desarrolló un marco metodológico para evaluar el funcionamiento hidráulico del sistema de alcantarillado de una cuenca piloto. Mediante tres tipos de información, espacial, temporal y topográfica, se generaron principalmente lluvias de diseño, lluvias históricas, caudales y patrones de agua residual, topología del SDU del área de estudio, usos, cobertura del suelo, DTM, DSM, ortofoto, consecuentemente el modelo hidrodinámico 1D de drenaje urbano fue construido. Mediante mediciones hidrometeorológicas registradas en sensores ultrasónicos para medir calados y velocidades del flujo en las tuberías y un pluviómetro, se calibro y valido el modelo de drenaje.
- Published
- 2024
- Full Text
- View/download PDF
9. Clinimetric properties of the Perme Intensive Care Unit Mobility Score -a multicenter study for minimum important difference and responsiveness analysis.
- Author
-
Kenji Nawa, Ricardo, Ferreira De Camillis, Marcio Luiz, Buttignol, Monique, Kutchak, Fernanda Machado, Chaves Pacheco, Eder, Rodrigues Gonçalves, Louise Helena, Correa Garcia, Leonardo Miguel, Timenetsky, Karina Tavares, and Alberto Forgiarini Junior, Luiz
- Subjects
- *
RESEARCH , *CONFIDENCE intervals , *RETROSPECTIVE studies , *RECEIVER operating characteristic curves , *SENSITIVITY & specificity (Statistics) , *PREDICTIVE validity , *ODDS ratio ,RESEARCH evaluation - Abstract
Background: The use of instruments in clinical practice with measurement properties tested is highly recommended, in order to provide adequate assessment and measurement of outcomes. Objective: To calculate the minimum clinically important difference (MCID) and responsiveness of the Perme Intensive Care Unit Mobility Score (Perme Score). Methods: This retrospective, multicentric study investigated the clinimetric properties of MCID, estimated by constructing the Receiver Operating Characteristic (ROC). Maximizing sensitivity and specificity by Youden's, the ROC curve calibration was performed by the Hosmer and Lemeshow goodness-of-fit test. Additionally, we established the responsiveness, floor and ceiling effects, internal consistency, and predictive validity of the Perme Score. Results: A total of 1.200 adult patients records from four mixed general intensive care units (ICUs) were included. To analyze which difference clinically reflects a relevant evolution we calculated the area under the curve (AUC) of 0.96 (95% CI: 0.95-0.98), and the optimal cut-off value of 7.0 points was established. No substantial floor (8.8%) or ceiling effects (4.9%) were observed at ICU discharge. However, a moderate floor effect was observed at ICU admission (19.3%), in contrast to a very low incidence of ceiling effect (0.6%). The Perme Score at ICU admission was associated with hospital mortality, OR 0.86 (95% CI: 0.82-0.91), and the predictive validity for ICU stay presented a mean ratio of 0.97 (95% CI: 0.96-0.98). Conclusions: Our findings support the establishment of the minimum clinically important difference and responsiveness of the Perme Score as a measure of mobility status in the ICU. [ABSTRACT FROM AUTHOR]
- Published
- 2023
- Full Text
- View/download PDF
10. 20 años de experiencia en la protección radiológica ocupacional en la práctica de calibración dosimétrica.
- Author
-
González Rodríguez, Niurka and Walwyn Salas, Gonzalo
- Subjects
- *
RADIATION protection , *CALIBRATION , *IONIZING radiation , *RADIATION sources , *SAFETY , *MEDICAL dosimetry , *TESTING laboratories - Abstract
The Center for Radiation Protection and Hygiene (CPHR) is the institution in Cuba that provides dosimetric calibration services of instruments at radiationl protection, radiotherapy, diagnostic radiology and interventionism level. This practice is developed by the Secondary Standard Dosimetric Laboratory and guarantees the metrological traceability of dose magnitudes to a Primary Standard Dosimetric Laboratory. It is carried out in compliance with a strict Radiation Protection Program designed to guarantee the radiation safety of people and the environment and to obtain the Operating License established in the national regulatory framework. The radiation protection program includes the necessary provisions to ensure the radiation protection of people while working with ionizing radiation sources. The safety of the personnel is one of the key elements of the program and is based on requirements such as radiological control both individually and of the workplaces, the design of the facilities, operational and safety procedures and inventory control, among other aspects that have allowed compliance with the annual dose constraints imposed by the Regulatory Authority for this category of exposed personnel. This paper presents the experiences in the application of these requirements for more than 20 years. [ABSTRACT FROM AUTHOR]
- Published
- 2023
11. Evaluación comparativa de sensores de partículas en Santa Clara, Cuba.
- Author
-
Cruz, Arianna Alvarez, Pérez, Mayra C. Morales, Sánchez, Daniellys Alejo, Rivero, Rosa Amalia González, and Santana, Luis Hernández
- Subjects
- *
AIR pollutants , *PARTICULATE matter , *STANDARD deviations , *AIR quality monitoring , *DETECTORS , *GRAVIMETRY , *DUST , *MICROBIOLOGICAL aerosols - Abstract
Particulate matter is one of the criteria air pollutants regulated according to standards established by the WHO and national regulations. Technological advances have allowed the development and implementation of low-cost sensors for monitoring, but they present limitations in the reliability of their data. This article aims to evaluate two low-cost sensor models (OPC-N3 and SDS011) in a field study in the rainy period with and without Saharan dust impact in Santa Clara, Cuba. For this purpose, PM10 and PM2.5 are monitored at three sampling sites on the main road of Santa Clara. The performance of OPC-N3 in measuring PM10, compared to the concentration determined by gravimetry in a small volume sampler, is calculated using two performance indicators, the root mean square error (RMSE) and the Willmott index (d). The results correspond to the characteristics of the evaluated scenarios, demonstrating the reliability of the measurements of particulate matter concentrations for the two sensors and the OPC-N3 calibration experiments for PM10 in the laboratory were satisfactory with low RMSE values and a Willmott of 0.95. The evaluation of the OPC-N3 and SDS011 sensors under field conditions in the two scenarios demonstrated the reliability of their measurements, the calibration of the OPC-N3 sensor with the reference instrument shows the feasibility of using this sensor for the measurement of PM10. [ABSTRACT FROM AUTHOR]
- Published
- 2023
12. Calibración de equipos de laboratorio en entornos universitarios: estrechando la brecha en materia de gestión metrológica
- Author
-
Manfred Murrell-Blanco, Ernesto Montero-Sánchez, Sherryl Campos-Morales, Ligia Bermúdez-Hidalgo, and Karla Vetrani-Chavarría
- Subjects
calibración ,equipo e instrumentos de laboratorio ,gestión metrológica ,personal de laboratorio ,Technology - Abstract
En los laboratorios universitarios se generan datos que nutren las actividades de investigación y docencia; además, brindan soporte a diferentes sectores productivos y en algunos casos suministran información para la toma de decisiones con alcance legal. Por lo tanto, es necesario asegurar la calidad de sus resultados mediante la implementación de acciones tendientes al mejoramiento de sus mediciones; este sentido, el objetivo de este estudio fue desarrollar una estrategia para la calibración de equipos y cristalería de laboratorio de la Universidad Nacional de Costa Rica (UNA) con el fin de disminuir la brecha en materia de gestión metrológica. Entre los hallazgos más relevantes están que los laboratorios universitarios cuentan con poco o nulo presupuesto para la gestión metrológica de sus mediciones, lo que dificulta atender requerimientos como la calibración de equipos y la capacitación de personal. Además, dependen administrativamente de otras instancias universitarias como escuelas e institutos, lo que limita su capacidad de respuesta en materia de oferta de servicios a usuarios externos. En el caso específico de la UNA, se han realizado inversiones importantes en equipamiento y capacitación de personal. Sin embargo, no se han logrado abarcar todas las necesidades de trazabilidad de los laboratorios, lo que impide la completa gestión de la calidad de los resultados. Este estudio ha identificado mecanismos para que los laboratorios cuenten con mediciones trazables al Sistema Internacional de Unidades (SI), aumentando la confianza en sus resultados, permitiendo la detección de problemas e inclusive disminuyendo la presión económica por el rubro de calibraciones.
- Published
- 2023
- Full Text
- View/download PDF
13. Environmental Noise - Integrating and sharing geographic data sets.
- Author
-
Antunes, Cristina, Cunha, Sofia, Baltazar, Luís, and Cruz, Paulo
- Abstract
Noise is a major environmental concern. To address this issue, the European Commission (EC) launched the Environmental Noise Directive (END), whose main objective is to assess and manage noise from various sources, including airports, roads, railways and agglomerations. An effective implementation of END requires the harmonisation of data supplied by various national agencies such as municipalities and airport authorities. This paper presents the Portuguese approach to the harmonization of data, as part of the END implementation, which was coordinated by the Portuguese Environmental Agency (APA). It also describes a set of principles and procedures developed by APA to ensure data harmonization and integration in a single platform, which provides interoperable information to decision makers, key stakeholders and general public, through Web Services. [ABSTRACT FROM AUTHOR]
- Published
- 2023
- Full Text
- View/download PDF
14. Dating Marine Shell: A Guide for the Wary North American Archaeologist.
- Author
-
Hadden, Carla S., Hutchinson, Ian, and Martindale, Andrew
- Subjects
- *
ARCHAEOLOGISTS , *RADIOCARBON dating - Abstract
Radiocarbon dates on marine shell and other materials of marine origin appear significantly older than contemporaneous samples of terrestrial/atmospheric origin. Misunderstandings regarding the mechanisms that give rise to this "marine reservoir effect" (MRE), the terminology used to define it, and the mathematics used to describe it cause many coastal archaeologists to distrust or misinterpret marine shell dates. The recent release of a reformulated 14C calibration curve for marine samples (Marine20), which necessitates recalculation of all local reservoir age corrections, may add to the confusion. Here, we review the benefits of dating shell; provide a plain-language explanation of the mechanical, chemical, biological, and cultural processes that give rise to age disparities associated with the MRE; and offer advice to archaeologists intending to date marine shell. Our hope is that these comments will not only aid archaeologists in the planning and interpretive stages of research but also assist in assessing the reliability of legacy chronologies based on marine materials. More broadly, we encourage careful evaluation of all sources of uncertainty in all 14C chronologies, whether based on terrestrial or marine materials. [ABSTRACT FROM AUTHOR]
- Published
- 2023
- Full Text
- View/download PDF
15. Los juicios metacognitivos como tendencia emergente de investigación. Una revisión conceptual.
- Author
-
Olaya Torres, Adriana Julieth, Montoya Londoño, Diana Marcela, Gutierrez de Blume, Antonio P., and Puente Ferreras, Aníbal
- Subjects
- *
LITERATURE reviews , *JUDGMENT (Psychology) , *STUDENT financial aid , *ARCHIVAL resources , *PERFORMANCES , *LEARNING , *METACOGNITION - Abstract
Objective: The purpose of the current article is to conduct a conceptual revision of the term "metacognitive judgment." Methodology: For the thematic review of the literature written by some of the most important authors in the field, 55 archival sources were taken into consideration. These sources were examined through the following stages: introduction, reflection, and establishment of conclusions. Results: It is established that metacognitive judgments are seen as the construct that brings together the students' beliefs about what they know and do not know, as well as their control and regulation over their learning. Conclusion: The study of metacognitive judgments is put out as an alternative to aid students in self-regulating their learning so they can become gradually more accurate in assessing their performance. [ABSTRACT FROM AUTHOR]
- Published
- 2023
- Full Text
- View/download PDF
16. Application of the method of ordinary least squares in the calibration of temperature, pressure and mass meters.
- Author
-
Pedraza Yepes, Cristian Antonio, Vitola Galvis, Mauricio Antonio, Higuera Cobos, Oscar Fabián, Hernández Vásquez, José Daniel, and Fong Silva, Waldyr
- Subjects
CALIBRATION ,TEMPERATURE ,MAYORS ,PARTIAL least squares regression - Abstract
Copyright of Investigación e Innovación en Ingenierías is the property of Universidad Simon Bolivar and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
- Published
- 2023
- Full Text
- View/download PDF
17. Validation of a standardized performance test for selection of Architecture students with the Many-Facet Rasch Measurement Model.
- Author
-
Hernández-Ureña, Olman and Montero-Rojas, Eiliana
- Subjects
RASCH models ,ABILITY testing ,EMPLOYEE reviews ,UNDERGRADUATE programs ,LOGITS - Abstract
Copyright of Revista de Arquitectura (1657-0308) is the property of Universidad Catolica de Columbia, Facultad de Arquitectura and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
- Published
- 2023
- Full Text
- View/download PDF
18. Datación por liquenometría aplicada en geomorfología, clima y arqueología.
- Author
-
Pérez-López, R.
- Subjects
GEOCHRONOMETRY ,ROCKFALL ,LICHENS ,HOLOCENE Epoch ,GEOMORPHOLOGY ,LANDSLIDES - Abstract
Copyright of Cuaternario y Geomorfología is the property of Cuaternario y Geomorfologia and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
- Published
- 2022
- Full Text
- View/download PDF
19. Simulación hidrológica de la cuenca del río Laja con el modelo WEAP
- Author
-
Claudia Molina-Sánchez, Jesús Chávez-Morales, Oscar Luis Palacios-Vélez, and Laura Alicia Ibáñez-Castillo
- Subjects
modelación hidrológica ,weap ,calibración ,validación ,escurrimientos ,río laja ,Hydraulic engineering ,TC1-978 ,Water supply for domestic and industrial purposes ,TD201-500 - Abstract
La cuenca del río Laja se localiza entre los paralelos 21° 32’ 58”, 20° 16’ 14” N y los meridianos -100° 6’ 28” -101° 30’ 44” O; en 2014 fue clasificada con grado de presión alto sobre el recurso hídrico (Conagua, 2014); ocupó el segundo lugar como región hidrológica administrativa con mayor densidad de población, y presentó fuertes problemas con oferta y demanda del recurso, lo que motivó llevar a cabo este trabajo. Se realizó una modelación hidrológica en WEAP (Water Evaluation and Planning) con el método de humedad del suelo. El objetivo fue calibrar, validar y estimar escurrimientos superficiales, considerando efectos del cambio en precipitación. Se utilizó información de uso y características físicas de suelo, coeficientes de cultivo y datos mensuales promedios de precipitación, temperaturas medias, humedad relativa, velocidad del viento. Los procesos de calibración y validación se efectuaron en cuatro puntos de la cuenca para un periodo de cinco años por mes en las siguientes estaciones hidrométricas: Puente Dolores, Begoña II, Tres Guerras y Pericos; para cada una de ellas se estimó el coeficiente de determinación (r2) e índice de eficiencia Nash-Sutcliffe (NSE), y se obtuvieron valores de r2 de 0.8 a 0.82, y de NSE de 0.55 a 0.77 en calibración, y r2 de 0.65 a 0.86 y NSE de 0.57 a 0.75 en validación. Se generó información climática con WGEN para 10 años, para generar escurrimientos con las proyecciones del escenario RCP8.5 para el periodo 2012-2022. Se concluye que WEAP es un software capaz de simular correctamente la respuesta de la cuenca del río Laja con el método de humedad del suelo. WEAP simuló correctamente los flujos medidos en la estación de medición con un error absoluto medio inferior al 10 %.
- Published
- 2022
- Full Text
- View/download PDF
20. Calibración de la curva número del modelo SCS para la región de la costa norte del Perú
- Author
-
Jhon Alberca, Jesús A. Mejía, and Edilberto Guevara-Pérez
- Subjects
CN ,calibración ,modelo matemático SWAT ,Script R ,PISCO ,Engineering (General). Civil engineering (General) ,TA1-2040 ,Technology (General) ,T1-995 - Abstract
En las últimas décadas, la variación espacial de los recursos hídricos y otros cambios climáticos vienen siendo las principales razones de eventos extremos como sequías e inundaciones. El objetivo del presente artículo fue calcular el valor de CN para la costa norte del Perú, donde se han evidenciado inundaciones de gran magnitud, ya que este parámetro es fundamental para estimar caudales. Se utilizó el modelo hidrológico SWAT para calcular el valor de CN de la subcuenca medio-alta del río Piura, tomando como punto de aforo el puente Sánchez Cerro. Posteriormente, se calculó los caudales a paso mensual en el punto de aforo, los mismos que se compararon con la información hidrométrica existente para el periodo comprendido entre enero de 1981 a diciembre del 2016. Los resultados indicaron una confiabilidad de 0,93 (para coeficiente de Nash Sutcliffe) y un valor 0,97 (para coeficiente de correlación de Pearson r), considerados como excelentes. El valor CN reflejó con bastante exactitud las características del suelo de la costa norte peruana, con mayor aproximación incluso que si se utiliza la tabla de valores de CN del Servicio de Conservación de Suelos (SCS) o los valores del mapa ráster elaborado por la Autoridad Nacional del Agua (ANA).
- Published
- 2023
- Full Text
- View/download PDF
21. Validación de una prueba estandarizada de desempeño para la selección de estudiantes de Arquitectura con el Modelo de Rasch de Facetas Múltiples
- Author
-
Olman Hernández-Ureña and Eiliana Montero-Rojas
- Subjects
arquitectura ,calibración ,evaluación ,evaluación de desempeño ,método de evaluación ,modelo de Rasch ,Architecture ,NA1-9428 - Abstract
En una evaluación del desempeño se crea un producto o se desarrolla un proceso, que es evaluado por varios calificadores. El Modelo de Rasch de Facetas Múltiples (MRFM), extensión del modelo de Rasch, cuantifica diversos atributos asociados a la calidad de la medición en tales evaluaciones, incluyendo la concordancia entre calificadores, cualidad esencial para la validez. Los datos provienen de una prueba de desempeño aplicada con propósitos de selección en la Escuela de Arquitectura de la Universidad de Costa Rica (UCR). Se analizaron las aplicaciones de la prueba del 2015 al 2018, cada una tenía entre 600 y 800 examinados. Cada producto fue evaluado por tres calificadores, y los equipos de calificadores tenían entre 12 y 15 miembros. Los tres primeros años mostraron alto grado de variabilidad entre las severidades de los calificadores, dispersándose más de 2 logits, en la escala de Rasch. En 2018 se introdujeron modificaciones para mejorar la concordancia entre los calificadores, y los análisis correspondientes mostraron una disminución relevante en la dispersión de las severidades, con un rango de 1.09 logits. El estudio ilustra los beneficios de este modelo para analizar y mejorar la calidad técnica de una evaluación del desempeño de alto impacto.
- Published
- 2023
- Full Text
- View/download PDF
22. Calibración de PET/TC para adquisición de estudio de cuerpo estándar postratamiento con esferas de resina de ytrio-90.
- Author
-
Uña-Gorospe, J.A., Baso-Pérez, C., Cárdenas-Negro, C., Merino-Gestoso, J.A., Portas-Ferradás, B.C., and Allende-Riera, A.
- Abstract
Entre los objetivos en los tratamientos con esferas marcadas con ytrio-90 figura demostrar que se consigue la dosis tumoricida y que se evitan dosis hepatotóxicas, así como que no existe deposición extrahepática. Utilizamos diferentes cantidades de ytrio y un maniquí NEMA NU2-2007 para comprobar si el tomógrafo mantiene una respuesta que permita hacer cálculos dosimétricos reales. El tomógrafo Gemini responde de manera lineal en un rango amplio de actividades con una R
2 = 0,9983. La capacidad de detección del equipo PET nos permite realizar estudios de cuerpo estándar con finalidad dosimétrica con tiempos de 5 min por BED, que además hacen posible verificar la ausencia de deposición extrahepática de cantidades significativas de esferas de ytrio-90. Among the objectives in treatments with yttrium-90 spheres is to demonstrate that the tumoricidal dose is achieved and that hepatotoxic doses are avoided, as well as that there is no extrahepatic deposition. We use different amounts of yttrium-90 resin micro-spheres and a NEMA NU2-2007 phantom to check if the scanner maintains a response that allows real dosimetric calculations. The Gemini tomograph responds linearly in a wide range of activities with R2 = 0.9983. The detection capacity of the PET equipment allows us to carry out standard body studies with dosimetric purposes with times of five minutes per BED. It also make possible to verify the absence of extrahepatic deposition of significant amounts of yttrium 90 spheres. [ABSTRACT FROM AUTHOR]- Published
- 2022
- Full Text
- View/download PDF
23. Electrical Impedance Tomography to Measure Spirometry Parameters in Chronic Obstructive Pulmonary Disease Patients.
- Author
-
Vargas Luna, Francisco Miguel, Kashina, Svetlana, Riu Costa, Pere Joan, Casan Clarà, Pere, and Balleza Ordaz, José Marco
- Subjects
- *
ELECTRICAL impedance tomography , *SPIROMETRY , *CHRONIC obstructive pulmonary disease , *FOURIER transforms , *RESPIRATION - Abstract
Spirometry is a test for the diagnosis of chronic obstructive pulmonary disease. It is a technique that can be intolerant due to the essential use of a mouthpiece and a clamp. This study proposes the use of electrical impedance tomography to measure respiratory parameters. Patients underwent spirometry and three respiratory exercises. The impedance signals were convolved, and the resultant was analyzed by fast Fourier transform. The frequency spectrum was divided into seven segments (R1 to R7). Each segment was represented in terms of quartiles (Q25%, Q50%, Q75%). Each quartile of each segment was correlated with the spirometric parameters to obtain a fitting equation. FVC was correlated 70% with the 3 quartiles of R7, 3 equations were obtained with a fit of 60%. FEV1 correlated 70% with the Q50% of R7, obtaining an equation with a fit of 40%. FEV1/FVC correlated 69% with Q75% of R2, obtaining an equation with a fit of 60%. Spirometric parameters can be estimated from the implied carrier frequency components of the ventilatory impedance signal. [ABSTRACT FROM AUTHOR]
- Published
- 2022
- Full Text
- View/download PDF
24. Aporte de la corrección de dispersión por Tomografía para la estimación de actividad en estudios híbridos del tiroides con 131I.
- Author
-
Machado López, Katlyn, López Díaz, Adlin, Robaina León, Yalaina, Martín Escuela, Juan Miguel, and Fernández Rodríguez, Viviana M.
- Subjects
- *
SINGLE-photon emission computed tomography , *TOMOGRAPHY , *BIAS correction (Topology) , *THYROID gland , *HYPERTHYROIDISM - Abstract
Hyperthyroidism is one of the most frequent MN treatments; however, quantification of 131I activity in thyroid using Single Photon Computer Tomography (SPECT) and combined with Computer Tomography (SPECT/CT techniques has almost no bibliographic history. This work studied the impact on 131I activity accuracy quantification of scatter corrections using CT information. Three sources of known activity were used for the calibration process (1.06 MBq 2.61 MBq and 4.66 MBq) with a typical uncertainty of 2.4 % and the classic thyroid phantom. The calibration factors and their uncertainty were calculated for each case. To analyze the accuracy of the system, a set of 11 sources (with activities between 1.37 MBq-3.92 MBq) were calculated and the uncertainty was estimated in each case. The relative discrepancies of the calculated activity versus reference were compared (p<0.05). The lowest average discrepancy resulted was 3 % (from 5 to 7 %) corresponding with any correction using CT. The uncertainties were found in the range of 9 to 11 %, being consistent with the discrepancies already found. Conclusions: The corrections of attenuation and dispersion by MC using CT information did not improve the 131I activity quantification accuracy in the geometry of classical thyroid phantom; although it is recommended to expand the range of masses of the thyroid to better represent the wide specific patient clinical situation and confirm these results. [ABSTRACT FROM AUTHOR]
- Published
- 2022
25. Una mirada actualizada a las dificultades en la implementación y diseminación de los patrones dosimétricos secundarios.
- Author
-
Walwyn Salas, Gonzalo, Díaz Rizo, Oscar, and González Rodríguez, Niurka
- Subjects
- *
MEDICAL dosimetry , *UNITS of measurement , *NUCLEAR counters , *RADIATION dosimetry , *STANDARDS , *CRITICAL analysis - Abstract
A basic element to achieve the measurement traceability is the correct implementation and dissemination of the measurement standards. In the case of dosimetry, there are internationally harmonized calibration methods; however difficulties may arise in their introduction related to the technical characteristics of the standards and the methods described in the technical documents. The use of commercially available dosimetry systems as secondary standards requires the personalized studies of their technical characteristics. The recommended methods do not always compatible with the available infrastructure and modifications are needed. The article makes a critical analysis of the implementation of the dosimetry secondary standards in the international arena based on the identified difficulties. [ABSTRACT FROM AUTHOR]
- Published
- 2022
26. Propuesta de implementación de los requisitos contenidos en la norma NTC ISO/IEC 17025:2017 como herramienta para la acreditación de los ensayos realizados en el laboratorio de química inorgánica de la Universidad de América
- Author
-
Camargo Salinas, Mónica Andrea, Hernández Prieto, Jenny Paulina, Camargo Salinas, Mónica Andrea, and Hernández Prieto, Jenny Paulina
- Abstract
En el presente trabajo se realiza un diagnóstico inicial de las condiciones de cumplimiento de los requisitos contenidos en la norma NTC ISO 17025:2017, con las que cuenta el laboratorio de química inorgánica de la Universidad de América, adicionalmente se analizan de los riesgos asociados, para posteriormente proponer un plan de acción y determinar la viabilidad financiera, para así a futuro presentarse ante la ONAC (Organismo Nacional de Acreditación de Colombia) con miras de conseguir la acreditación de los ensayos allí desarrollados y de esta manera incrementar la fiabilidad de los resultados obtenidos y el reconocimiento de la institución.
- Published
- 2024
27. Calibración y mantenimiento de aparatos de láser de baja potencia: estudio descriptivo
- Author
-
Ernesto Benítez and María del Carmen Ferreiro
- Subjects
terapia por luz de baja intensidad ,calibración ,evaluación de la tecnología biomédica ,Medicine ,Nursing ,RT1-120 - Abstract
Introducción: El láser de baja potencia es una técnica utilizada en varias áreas de la salud: fisioterapia, odontología, otorrinolaringología y dermatología, entre otras. Para lograr los efectos terapéuticos la dosificación es fundamental y depende de los niveles de energía emitidos por los equipos. Objetivo: Conocer el estado de calibración y mantenimiento de los equipos de laserterapia de baja potencia, en servicios de fisioterapia u homólogos de instituciones de Montevideo, Uruguay. Método: Se realizó un estudio descriptivo, transversal en servicios de fisioterapia de Montevideo. Se analizaron 20 equipos de láser de baja potencia. Resultados: 7 de los aparatos evaluados se mantuvieron dentro de los límites adecuados de emisión. De los 13 láser fuera de los límites para entregar una emisión adecuada, 6 tenían un desajuste leve, 1 presentaba un desajuste moderado y 6 presentaban un desajuste severo con dosis nulas o que no generaban emisión. Del total de equipos evaluados solo 6 habían realizado una calibración previa y solo 2 de estos se encontraban dentro de los tiempos recomendados. Conclusión: Se observó un gran número de equipos de láser de baja potencia con desajustes en su emisión. En la mayoría de los casos no se lleva un correcto mantenimiento de los aparatos de láser de baja potencia. Se entiende relevante que los equipos sean calibrados para poder ofrecer una terapéutica segura y efectiva a los usuarios.
- Published
- 2022
- Full Text
- View/download PDF
28. Implementation and Evaluation of a Hail-Impact Simulation Device.
- Author
-
Blasina, Florencia, Echarri, Andrés, Farber, Gabriel, Molina, Federico, Machin, Sofía, and Pérez, Nicolás
- Subjects
- *
HAILSTORMS , *HAZARDOUS substances , *DETECTORS , *MATCHING theory , *IMPACT loads , *RESEARCH personnel , *STEEL - Abstract
Hailstorms are hazardous for people and goods. Automatically collecting information on hailstorms will help climate researchers analyze them and generate models for forecasting. Reproducing hail impacts is a requisite for designing and calibrating an electronic hail sensor. In this article, the design of a device for hail-impact simulation is presented. This device is based on the theory of Energy Matching, which explains how steel balls can be used instead of hailstones in order to have equivalent impact energies. The posed device, which can perform up to fourteen impacts between loading instances, either by dropping balls one by one or in pairs, was constructed. The size of the balls can be between 0.5 cm and 3.0 cm. In this paper, which is an extension of the work originally presented at the URUCON2021 conference, the importance of having such a hail-impact simulation device is explained. The main contribution of this extended work is the presentation of an experiment performed as an application of the constructed device. This experiment has the objective of verifying the aiming repetitiveness, while also verifying the linear relation between impact and electric signal energies. [ABSTRACT FROM AUTHOR]
- Published
- 2022
- Full Text
- View/download PDF
29. Modelación hidráulica y calibración de redes de distribución de agua potable
- Author
-
Walter Rodríguez-Procel and Holger Benavides-Muñoz
- Subjects
redes hidráulicas ,calibración ,algoritmos genéticos ,simulación hidráulica ,análisis de red ,Hydraulic engineering ,TC1-978 ,Water supply for domestic and industrial purposes ,TD201-500 - Abstract
El objetivo del estudio fue modelar y analizar tres redes de distribución de agua potable; calibrarlas con el software Epanet Calibrator, y comparar sus resultados con Darwin Calibrator. Se utilizaron un caudalímetro ultrasónico y data loggers de presión que fueron configurados para registrar datos cada diez minutos; se obtuvo la media de los caudales en cada nudo de interés de la red. Se utilizaron los datos de presión para ajustar cada red; al variar rugosidades se pudo calibrar y ajustar el modelo entre lo simulado matemáticamente con los datos obtenidos en campo. Mediante esta información se establecieron ecuaciones y curvas de calibración para discriminar la discrepancia entre lo modelado y lo observado en campo. Las calibraciones hidráulicas se hicieron mediante las fórmulas de Darcy-Weisbach y Hazen-Williams. Los resultados muestran para cada red una variación en las calibraciones del 35, 15 y 10 %. Se concluye que estas dos aplicaciones computacionales arrojan resultados similares entre los datos de lo simulado y lo observado con la diferencia de que la calibración en Epanet se hace nudo por nudo, mientras que en Darwin Calibrator puede efectuarse mediante grupos de calibraciones en un determinado sector.
- Published
- 2021
- Full Text
- View/download PDF
30. Certificado de Calibración la Llave de la Confirmación Metrológica.
- Author
-
Ponce Rodríguez, Alhelí, Crisanto Arriaga, Alejandro, and Pérez Vera, Jorge
- Abstract
Copyright of Congreso Internacional de Investigacion Academia Journals is the property of PDHTech, LLC and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
- Published
- 2021
31. Incertidumbre asociada a la indicación de los instrumentos para pesar verificados
- Author
-
Luis Omar Becerra Santiago and Luis Manuel Peña
- Subjects
calibración ,incertidumbre ,instrumentos para pesar ,verificación ,Engineering (General). Civil engineering (General) ,TA1-2040 - Abstract
En el presente trabajo se estima la incertidumbre asociada a la indicación en uso de los instrumentos para pesar de funcionamiento no automático el cual ha sido verificado acorde a la recomendación internacional OIML R76. Esta recomendación de la Organización Internacional de Metrología Legal (OIML) de sirve de base para la verificación de los instrumentos para pesar de funcionamiento no automático para la gran mayoría de los países, sin embargo, no se conoce de manera explicita el valor de incertidumbre asociada a los resultados de los instrumentos verificados durante su uso.
- Published
- 2021
- Full Text
- View/download PDF
32. Solución del problema inverso de la hidrogeología mediante el algoritmo evolución diferencial.
- Author
-
Verdés Sánchez, Rolando, Ramos Arzola, Lemuel Carlos, and Hernández Valdés, Armando Orestes
- Subjects
- *
HYDROGEOLOGY , *OPTIMIZATION algorithms , *DIFFERENTIAL evolution , *HYDRAULIC conductivity , *METAHEURISTIC algorithms , *GENETIC algorithms , *THERMAL conductivity , *BIOLOGICAL systems , *INVERSE problems , *AQUIFERS - Abstract
In this research a new module within AQÜIMPE technology is proposed, to the automatic calibration of the hydrogeologic parameters of the aquifers model (hydraulic conductivity and storage coefficient). The proposal uses a metaheuristic technique called differential evolution algorithm, which is based on the basic principles of the genetic algorithms with some modifications. This technique is implemented in the solution of the inverse problem of the hydrogeology. The coupling between the AQÜIMPE flow model code and DE is implemented in the mathematical assistant MATLAB. The model proposed is applied in the calibration of the real aquifer model. Through its application it shows that DE is a good option when selecting an optimization algorithm to the solution of the inverse problem of the hydrogeology. [ABSTRACT FROM AUTHOR]
- Published
- 2022
33. Applying hydrological modeling to unravel the effects of land use change on the runoff of a paramo ecosystem.
- Author
-
José Cabrera-Balarezo, Juan, Esteban Sucozhañay-Calle, Adrián, Javier Crespo-Sánchez, Patricio, and Manuel Timbe-Castro, Luis
- Subjects
- *
LAND use , *HYDROLOGIC models , *RUNOFF , *WATERSHEDS , *AFFORESTATION , *HYDROLOGY - Abstract
To gain insights into the impact of afforestation on the hydrology of a mountain river basin, the Mpinos catchment was modeled to obtain parameters that represent pine land use. Thereafter, the parameters were applied in the Zhurucay catchment to answers the following questions: 1) How can the parameters of hydrological models subject to land use change be calibrated? 2) What is the impact on peaks, total flow, and baseflow when land use gradually changes from tussock grass to pine plantations? 3) Is the impact different when land use changes gradually from upstream to downstream (U-D) or downstream to upstream (D-U)? Based on our results, the total flow, baseflow, and peaks were reduced by 21%, 66%, and 21%, respectively. Overall, this study presents a calibration approach to predict the effects of land-use change prior to its occurrence. [ABSTRACT FROM AUTHOR]
- Published
- 2022
- Full Text
- View/download PDF
34. Simulación hidrológica de la cuenca del río Laja con el modelo WEAP.
- Author
-
Molina Sánchez, Claudia, Chávez-Morales, Jesús, Luis Palacios-Vélez, Oscar, and Alicia Ibáñez-Castillo, Laura
- Subjects
HUMIDITY ,HYDROLOGIC models ,WATERSHEDS ,WIND speed ,WATER pressure ,SOIL moisture ,WATER requirements for crops - Abstract
Copyright of Tecnología y Ciencias del Agua is the property of Instituto Mexicano de Tecnologia del Agua (IMTA) and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
- Published
- 2022
- Full Text
- View/download PDF
35. Desarrollo de Instrumentos Virtuales en Excel como Apoyo a la Enseñanza de la Metrología
- Author
-
Matías Waldino Orué, Juan Marcos Banegas, and Edgardo Cámara
- Subjects
laboratorio virtual ,laboratorio remoto ,excel ,metrología ,calibración ,instrumentación ,instrumento virtual ,Technology ,Engineering (General). Civil engineering (General) ,TA1-2040 ,Science (General) ,Q1-390 - Abstract
La tecnología como medio para la mejora del proceso de enseñanza-aprendizaje, ya sea a través del contacto físico en el aula o laboratorio, o por medio de sistemas virtuales en línea, tiene una potencialidad altamente positiva, haciendo posible profundizar la capacidad de asimilación de conceptos dando una nueva dimensión al aprendizaje significativo. En este trabajo, se exploran diferentes tecnologías útiles para la capacitación en metrología, y se realizan propuestas para el desarrollo de diferentes instrumentos virtuales en planillas Excel, como un recurso de fácil acceso por su masiva distribución en los ambientes educativos. Esta herramienta demostró su versatilidad tanto para el profesor como para el alumno, y su portabilidad permite una fácil migración entre diferentes plataformas con un simple intercambio de archivos. Cabe aclarar que el software utilizado para el desarrollo de los instrumentos virtuales ocupa un lugar privilegiado en la práctica metrológica dentro de los laboratorios de calibración, haciéndolo extremadamente competitivo, incluso frente a sus competidores gratuitos.
- Published
- 2020
- Full Text
- View/download PDF
36. Solución del problema inverso de la hidrogeología mediante el algoritmo evolución diferencial
- Author
-
Rolando Verdés Sánchez, Lemuel Carlos Ramos Arzola, and Armando Orestes Hernández Valdés
- Subjects
acuífero ,AQÜIMPE ,calibración ,evolución diferencial ,problema inverso ,Hydraulic engineering ,TC1-978 ,Environmental engineering ,TA170-171 - Abstract
La presente contribución propone un nuevo algoritmo de optimización dentro de la tecnología AQÜIMPE para la calibración automática de los parámetros hidrogeológicos de modelos de acuíferos (conductividad hidráulica y coeficiente de almacenamiento). La propuesta utiliza una técnica metaheurística llamada algoritmo evolución diferencial (differential evolution, DE por sus siglas en inglés) la cual se basa en los principios básicos de los algoritmos genéticos con algunas modificaciones. El acople entre el modelo de flujo AQÜIMPE y DE se implementa en el asistente matemático MATLAB. Se aplica el modelo propuesto en la calibración del modelo del acuífero Cuentas Claras, donde DE demuestra ser una buena opción a la hora de elegir un algoritmo de optimización para la solución del problema inverso de la hidrogeología.
- Published
- 2022
37. Espacios de color y perfiles de color en las IDE. Técnicas de gestión del color para la distribución correcta de información geográfica ráster y vector por la web.
- Author
-
Villa Alcázar, Guillermo, Arístegui Cortijo, Andrés, Rodríguez Cuenca, Borja, Rodríguez Sánchez-Montañez, Rosa, and de Tomás Gargantilla, Alfonso
- Subjects
- *
VIRTUAL machine systems , *COLORS , *WORKFLOW , *COLOR , *BRAND name products - Abstract
Nowadays it is common for the publication of geographic information to be carried out almost directly by the departments or people generating such information, who usually know superficially, in the best of cases, the techniques of color management. One might think that, by using monitors and computers both for editing and publishing data and for its "consumption", color management is no longer necessary. Unfortunately, this is not the case: editing and publishing are carried out using a huge variety of monitors (of different types -IPS, TN, OLED- brands, models, drivers ..., devices (desktop, mobile, virtual machines ...), operating systems and specific programs (desktop GIS, Thin clients, ETL tools ...) that use different libraries (GDAL ...). The "consumption" of information is done with the same variety of hardware and software. This article makes a brief review of the color management techniques that are applicable for the publication on the web and explains the factors to consider in the design of a workflow that avoids "surprises" in the colors that really reach the end user. [ABSTRACT FROM AUTHOR]
- Published
- 2022
38. Modelo multifactorial Heath-Jarrow-Morton: una aplicación práctica bajo la estructura de componentes principales.
- Author
-
García Gaona, Robinson Alexander
- Subjects
- *
INTEREST rates , *BOND prices , *ARBITRAGE , *EQUILIBRIUM , *BUSINESS enterprises - Abstract
The global and highly dynamic scenarios in which the world of finance develops are currently characterized by increasing volatility in interest rates. Due to this, it is necessary to establish methodologies and models that make it possible to understand such fluctuations in interest rates, in order for companies to adopt privileged positions against the competition. The present work makes a conceptual and practical approach to the Heath-Jarrow-Morton interest rate model, for this, the analysis will integrate the principal components approach in order to be able to determine the factors that help to further explain the dynamics of interest rates. In turn, a general context of the equilibrium and arbitrage-free approaches will be provided, on which all interest rate models are defined. In the case of the short rate simulations, the us Treasury Yield will be used. [ABSTRACT FROM AUTHOR]
- Published
- 2022
- Full Text
- View/download PDF
39. ANÁLISIS DE CALIDAD DE AGUA DEL RÍO CHIPALO POR EL VERTIMIENTO SANTA ANA 1 Y 2 UTILIZANDO EL MODELO QUAL2K.
- Author
-
Cuellar, Alexa F. and Lezama, Juan F.
- Subjects
TRAVEL time (Traffic engineering) ,WATER quality ,BIOCHEMICAL oxygen demand ,WATER pollution ,WATER use ,POLLUTANTS - Abstract
Copyright of Iteckne is the property of Universidad Santo Tomas, Division de Ingenierias and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
- Published
- 2022
- Full Text
- View/download PDF
40. Estudio de la Capacidad de Medición y Calibración (CMC) de un Autocolimador Electrónico Nikon.
- Author
-
Guillermo Juan Bergues, Clemar Schürrer, and Nancy Brambilla
- Subjects
autocolimador electrónico ,calibración ,deformación óptica ,cmc ,Technology ,Engineering (General). Civil engineering (General) ,TA1-2040 ,Science (General) ,Q1-390 - Abstract
En este trabajo se estudian los resultados de la calibración de un autocolimador electrónico desarrollado en el Centro de Investigación y transferencia en Metrología -CEMETRO- de UTN FRC. El instrumento está construido en base a un autocolimador analógico comercial, Nikon 6D, y una interfaz visual ad hoc. La calibración fue realizada en el Laboratorio Nacional de Ángulo de Argentina, INTI Córdoba, con trazabilidad internacional al patrón de referencia, el autocolimador Trioptics TA300. El análisis de los resultados de la calibración permite obtener un modelo metrológico más preciso del autocolimador electrónico. Además, define pautas para optimizar las prestaciones del instrumento mediante ajustes de diseño de la interfaz visual electrónica conectada al autocolimador óptico Nikon 6D.
- Published
- 2020
- Full Text
- View/download PDF
41. DESARROLLO E IMPLEMENTACIÓN DE UN SISTEMA DE CALIBRACIÓN DE TERMÓMETROS CLÍNICOS INFRARROJOS DE OÍDO
- Author
-
Andrés J. Bohórquez, Ciro A. Sánchez, Sergio A. Carvajal, and Nelson D. Vargas
- Subjects
cuerpo negro ,termómetro de oído ,radiación térmica ,calibración ,metrología ,Physics ,QC1-999 ,Optics. Light ,QC350-467 - Abstract
En este trabajo se presenta el proceso de construcción e implementación de un sistema de calibración de termómetros clínicos de oído en el Laboratorio de Temperatura y Humedad del Grupo de Área Técnica 3 de la Subdirección de Metrología Física del Instituto Nacional de Metrología de Colombia, INM, usando una cavidad de cuerpo negro y un termómetro de contacto como patrones de medida. Como parte de la implementación y evaluación de la reproducibilidad del método de medición se diseñó un experimento basado en 54 mediciones independientes llevadas a cabo por tres operarios diferente a tres temperaturas (35 °C, 37 °C y 40 °C), con 6 réplicas por cada nivel. El análisis estadístico de las medias reveló una fuerte dependencia de la corrección en función de la temperatura, mientras que entre operarios no se evidenció una diferencia significativa, lo cual permitió concluir que el método implementado es reproducible. La incertidumbre de medición del sistema de medición fue de ± 0.14 °C, éste valor puede ser disminuido empleando un termómetro de referencia de mejor incertidumbre instrumental.
- Published
- 2020
- Full Text
- View/download PDF
42. Experience and lessons learnt in the design, fabrication and deployment of ceramic passive samplers for contaminant monitoring in water
- Author
-
Silvia Lacorte, Helena Franquet-Griell, Jorge Silva, and Victor M. Orera
- Subjects
Muestreadores pasivos cerámicos ,Contaminantes ,Agua ,Calibración ,Monitorización ,Clay industries. Ceramics. Glass ,TP785-869 - Abstract
The aim of this study is to describe the steps and complications encountered in the design, fabrication and calibration of ceramic passive samplers for the analysis of water contaminants. A ceramic passive samplers consists in a porous ceramic tube where a polymeric sorbent is placed in the inner side to preconcentrate the analytes from water with high enrichment factors. The diffusivity and uptake of contaminants depend on the ceramic porous structure that influences the sampling rate. Although the concept stands up for its simplicity, in real life passive samplers face several problems: fouling, clogging and saturation and then the uptake of contaminants may not be linear during the deployment period. With ceramic passive samplers these problems can be solved by optimizing the ceramic structure and porosity. Over eight year period, we have had a fruitful collaboration with Prof. Victor Orera, aimed to develop customized ceramic membranes to unselectively accumulate the contaminants present in different types of water with the overarching objective to monitor chemical pollution present in the environment. The use of customized ceramic passive samplers (CPS) will permit to identify main compounds in water, their evolution in time, identify the sources of pollution and finally gather enough knowledge and data to effectively propose control and remediation actions. In this study, we describe the steps undertaken in the development of ceramic samplers, their characteristics, the calibration procedure used, their performance and applicability. The work herein presented has been possible due to the brilliant ideas, enthusiasm, perseverance and motivation of Prof. Orera, but also because his joyful and cheerful character made this collaboration really pleasant and valuable. Resumen: El objetivo de este estudio es describir las etapas y complejidades halladas en el diseño, fabricación y calibración de muestreadores pasivos cerámicos para el análisis de contaminantes en agua. Los muestreadores pasivos cerámicos consisten en un cilindro cerámico poroso donde se coloca un adsorbente polimérico en el interior que permite preconcentrar los analitos del agua con elevados factores de enriquecimiento. La difusividad y la adsorción de contaminantes dependen de la estructura porosa de la cerámica que influye en la velocidad de muestreo. Aunque el concepto destaca por su simplicidad, en la vida real el uso de los muestreadores pasivos conlleva varios problemas: colmatación por partículas y materia orgánica, obstrucción y saturación, de manera que la adsorción de contaminantes puede no ser lineal. Con los muestreadores pasivos cerámicos, estos problemas se pueden resolver optimizando la estructura y la porosidad de la estructura cerámica. Durante un período de ocho años hemos tenido una fructífera colaboración con el Prof. Víctor Orera con el objetivo de desarrollar membranas cerámicas «a medida» para acumular de manera no selectiva los contaminantes presentes en distintos tipos de agua. El uso de muestreadores pasivos cerámicos permite identificar las fuentes de contaminación, los contaminantes más ubicuos y su evolución en el tiempo. La monitorización de la calidad del agua de forma sistemática mediante muestreadores pasivos proporciona nuevos datos que permiten proponer acciones de remediación de manera efectiva. En este artículo se describen los pasos realizados en el desarrollo de los muestreadores cerámicos, pretende destacar sus propiedades y el procedimiento de calibración, así como su rendimiento y aplicabilidad. Este estudio ha sido posible gracias al conocimiento, el entusiasmo, la perseverancia y la motivación del Prof. Orera, pero también por su carácter alegre y optimista que hizo esta colaboración realmente grata y valiosa.
- Published
- 2022
- Full Text
- View/download PDF
43. Desarrollo del Modelo Matemático para un Sistema de Calibración de Acelerómetros de Impacto con Base en el Péndulo Simple.
- Author
-
Gutiérrez León, Monserrat Guadalupe, Martínez Martínez, Silvia, Janeth Zúñiga-Osorio, Helen, and Del Llano Vizcaya, Luis
- Abstract
Copyright of Congreso Internacional de Investigacion Academia Journals is the property of PDHTech, LLC and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
- Published
- 2021
44. Calibración de toberas de flujo crítico por método volumétrico Cd
- Author
-
Jesús Eduardo Rivera López, Alejandro Díaz Martínez, Pedro Alejandro Tamayo Mesa, Guadalupe Juliana Gutiérrez Paredes, Gabriela Esmeralda Orozco Durán, and José Luis Arciniega Martínez
- Subjects
Flujo crítico ,Calibración ,Microtobera ,Estimación de la incertidumbre ,Patrones ,Engineering (General). Civil engineering (General) ,TA1-2040 ,Technology (General) ,T1-995 - Abstract
En el presente trabajo, se tiene por objetivo mejorar la medición de flujo de gases por medio del uso de toberas de flujo crítico (Critical Flow Venturi Nozzles), para ello, se describe el procedimiento de calibración de dos toberas de flujo crítico con diámetros en la garganta de 0.022 y 0.088 pulgadas. El procedimiento desarrollado tiene como base las recomendaciones que hace la Norma ISO 9300 para la estimación y cálculo del coeficiente de descarga “Cd” de las toberas de flujo crítico. La calibración se realizó en el Centro Nacional de Metrología (CENAM) con el uso de los patrones nacionales de flujo de gas. Los patrones utilizados o probadores son del tipo: Pistón y Campana, con un rango de medición de 0.05 a 50 L/min, y de 50 a 2840 L/min, respectivamente. El método utilizado para la calibración de las toberas fue mediante la comparación directa con el patrón.
- Published
- 2021
- Full Text
- View/download PDF
45. Desarrollo de una Aplicación Informática para la Calibración y Coordinación del Relevador de Sobre Corriente 50/51
- Author
-
Xavier Proaño, Cristian Castillo, Geovanny Rosales, Wilian Guamán, and Gabriel Pesantez
- Subjects
Relevador de sobrecorriente ,Protecciones Eléctricas ,Calibración ,Coordinación ,Technology (General) ,T1-995 - Abstract
En el presente trabajo se realizó el desarrollo de una aplicación informática para la coordinación y calibración de los relevadores de sobrecorriente 50/51 para sistemas radiales, mediante esta aplicación se llegó a observar las gráficas de las curvas de los relevadores modificando las variables de entrada como son Corriente del Tap (51) y Corriente del Instantáneo (50), TCs, Tipos de Curvas y su Dial para cada una de ellas, con el fin de calibrar y coordinar las protecciones entre curvas mediante el tiempo de actuación entre los Relevadores, en el programa Coordinación de Protección de sobrecorriente eléctrica (CPSElectric) desarrollado mediante la herramienta de programación Matlab r2019a, que se usó una de las aplicaciones incorporadas de esta plataforma como es la App Designer siendo está una de las nuevas opciones de programación en Matlab r2019a que permite reducir el tiempo de desarrollo de interfaces y la facilidad del diseño de las Aplicaciones para lo cual nos permite que el programa sea más interactivo a la hora de su uso ya que está enfocado para formar parte de laboratorio de protecciones eléctricas de la Universidad Técnica de Cotopaxi mejorando el aprendizaje de los estudiantes a la hora de debatir sobre las protección de sobrecorriente 50/51, permitiendo obtener la visualización de resultados como son los tiempos de operación de las corrientes del Instantáneo (50) y su tiempo de margen de operación entre curvas de forma gráfica para garantizar los resultados se basó a diferentes normas estandarizadas como son la IEEE Std C37.112-2018 “Estándar para ecuaciones de características de tiempo inverso para relés de sobrecorriente” y la IEC 60255-3 “Relés de medidas y equipos de protección.”
- Published
- 2021
- Full Text
- View/download PDF
46. Modelo lluvia-escurrimiento para la cuenca del río Yanuncay en Cuenca, Ecuador.
- Author
-
de Córdova Webster, Carlos Javier Fernández, Arias Lastre, Pedro Pablo, Rodríguez López, Yakelín, and León Méndez, Alcides Juan Felipe
- Subjects
- *
STREAMFLOW , *CALIBRATION , *FLOODS - Abstract
In the Yanuncay river that runs through the city of Cuenca, floods frequently occur due to the large discharge that flow through the river. The anticipated knowledge of these phenomena requires a detailed study of the rain-runoff relationship. In the present paper, the determination of this relationship was obtained through a calibration process with nine events (with maximum discharge contained in the range of 17, 1 to 101 m3 / s that occurred in two hydrometric stations) and a subsequent validation stage, with four new events, using for this the HEC-HMS program. The selected events for these stages allowed the process to be carried out, guaranteeing its representativeness for the flow interval with large return periods that could occur in the basin. [ABSTRACT FROM AUTHOR]
- Published
- 2021
47. Modelación hidráulica y calibración de redes de distribución de agua potable.
- Author
-
Rodríguez-Procel, Walter and Benavides-Muñoz, Holger
- Subjects
WATER distribution ,DRINKING water ,DATA loggers ,DATA recorders & recording ,CALIBRATION ,GENETIC algorithms - Abstract
Copyright of Tecnología y Ciencias del Agua is the property of Instituto Mexicano de Tecnologia del Agua (IMTA) and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
- Published
- 2021
- Full Text
- View/download PDF
48. Development of a Computer Application for the Calibration and Coordination of the 50/51 Overcurrent Relay.
- Author
-
Castillo, C. J., Rosales, G. E., Proaño, X. A., Guamán, W. P., and Pesantez, G. N.
- Subjects
APPLICATION software ,OVERCURRENT protection ,CALIBRATION ,ENGINEERING laboratories ,RETURNS on sales - Abstract
Copyright of Revista Técnica Energía is the property of Centro Nacional de Control de Energia CENACE and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
- Published
- 2021
49. Development of a semi-empirical method to determine the efficiency of a gamma radiation detector for point sources
- Author
-
Pablo Ortiz-Ramírez and Franco López-Usquiano
- Subjects
fuentes puntuales ,radiación gamma ,detectores de ge ultrapuro ,calibración ,precisión ,Nuclear engineering. Atomic power ,TK9001-9401 ,Medical physics. Medical radiology. Nuclear medicine ,R895-920 - Abstract
In the present work, we introduce the theoretical development and a new approach to validate a novel method to calibrate the efficiency of a gamma radiation detector for point sources, which we have named the “Efficiency Extrapolation Method”. The method consists in the determination of the detector efficiency using a set of monoenergetic gamma sources, which we will refer to as reference efficiencies. From these values, we will extrapolate the detector efficiency to the complete energy range using the first principle physics of gamma radiation detection theory. Therefore the proposed method corresponds to a semi-empirical one. The determination of reference efficiencies must be done experimentally, but in this work, simulations were performed using FLUKA code. The reference energies will be: 59,54 keV, 661,66 keV and 1 274,54 keV associated to the isotopes 241Am, 137Cs and 22Na respectively. The second part of the method, the extrapolation from the reference energies to the gamma range, will be done over the energies emitted by 152Eu and 133Ba. In general, the results are very good. While the obtained results for energies 53,16 keV and greater than 344,3 keV show an excellent agreement, the results obtained for energies in the middle range are only good.
- Published
- 2019
50. In vivo dosimetry in total body irradiation
- Author
-
E Llanes Veiga, R Alfonso Laguardia, and R Caballero Pinelo
- Subjects
in vivo ,dosimetría ,irradiación corporal total ,radioterapia ,calibración ,Nuclear engineering. Atomic power ,TK9001-9401 ,Medical physics. Medical radiology. Nuclear medicine ,R895-920 - Abstract
Total Body Irradiation (TBI) is a radiotherapy technique that consists of irradiating homogeneously the whole patient’s body and it is characterized by an extended source to surface distances and the use of large irradiation fields. The limitations of the available input data and inherent problems with the calculation procedures make it very difficult to accurately determine the dose distributions in TBI. For these reasons, it is highly recommended to use In Vivo Dosimetry (IVD), to guarantee the quality of TBI treatments as a direct measurement of the delivered dose. An IVD QA system was implemented based on semiconductor diodes and radiochromic films. For the commissioning of the system, both detector types were calibrated independently, using as reference an ionization chamber with a valid certificate in terms of absorbed dose to water (Dw). This guarantees the traceability of the measurements. An experiment was carried out to simulate a clinical TBI procedure to a phantom. In this way, the calibration of the dosimetry system was confirmed.
- Published
- 2019