1. Reproducibility of MRI Diagnosis of Female Genital Anomalies.
- Author
-
Elshetry, Al Shaimaa Fathi, Assy, Mostafa Mohamad, Zaid, Nesma Adel, El-fawakry, Rabab Mahmoud, Radwan, Mohamed Hesham Saleh Saleh, and Hamed, Enas Mahmoud
- Subjects
- *
FEMALE reproductive organ diseases , *T-test (Statistics) , *MAGNETIC resonance imaging , *MEDICAL societies , *RETROSPECTIVE studies , *DESCRIPTIVE statistics , *MEDICAL records , *ACQUISITION of data , *STATISTICS , *INTRACLASS correlation , *CONFIDENCE intervals , *COMPARATIVE studies , *DATA analysis software , *EVALUATION ,RESEARCH evaluation - Abstract
Purpose: To assess and compare intrareader and interreader reproducibility of magnetic resonance imaging (MRI) diagnosis of female genital anomalies (FGAs) using the American Society for Reproductive Medicine-Mullerian anomalies classification 2021 (ASRM-MAC 2021) and European Society of Human Reproduction and Embryology-European Society for Gynecological Endoscopy (ESHRE-ESGE) 2016 classification. Methods: In this retrospective study, we searched our electronic MRI database from April 2021 to September 2023, selecting MRI studies with FGAs. Seventy-six consecutive studies were included and reviewed by 4 independent radiologists using both classifications. Studies were re-evaluated after 1 month. Reproducibility was assessed using kappa (κ) scores with 95% confidence intervals (CI). Results: Intrareader agreement for MRI diagnosis of FGAs was substantial to excellent, with κ scores ranging from 0.684 (95% CI, 0.534-0.834) to 0.985 (95% CI, 0.963-1.01) using the ASRM-MAC 2021 and from 0.743 (95% CI, 0.621-0.865) to 0.846 (95% CI, 0.719-0.973) using the ESHRE-ESGE 2016 classification. Pairwise interreader agreement was higher with the ASRM-MAC 2021, ranging from moderate (κ = 0.491; 95% CI, 0.341-0.642) to substantial (κ = 0.709; 95% CI, 0.597-0.821), compared to the ESHRE-ESGE 2016 classification, with weak (κ = 0.080; 95% CI, 0.068-0.228) to moderate (κ = 0.511; 95% CI, 0.344-0.678) agreement. Overall interreader agreement was moderate for both classifications (κ = 0.599; 95% CI, 0.562-0.638 for ASRM-MAC 2021 and κ = 0.429; 95% CI, 0.396-0.463 for ESHRE-ESGE 2016 classification), but with significant differences (non-overlapping CIs). Conclusion: The intrareader reproducibility was high for both classifications, whereas the interreader reproducibility was higher using the ASRM-MAC 2021, highlighting the impact of classification criteria on the reproducibility of MRI diagnosis of FGAs. [ABSTRACT FROM AUTHOR]
- Published
- 2024
- Full Text
- View/download PDF