1. Ab-Externo XEN Gel stent implantation effectively treated refractory glaucoma with prior failed shunt tube
- Author
-
Anny M.S. Cheng, Shailesh K. Gupta, Geetha G. Vedula, Jackson Saddemi, Victor Wang, Rita Vartanian, David T.Y. Yang, and Aarup A. Kubal
- Subjects
Glaucoma drainage device ,Minimally invasive Glaucoma surgeries ,Shunt tube ,Tenonectomy ,XEN Gel Stent ,Ophthalmology ,RE1-994 - Abstract
Abstract Purpose To assess the efficacy of a gelatin stent (XEN 45 Gel Stent; Allergan) implant in advanced glaucoma eyes that have failed prior aqueous shunt implantation. Methods We retrospectively reviewed 6 patients with refractory glaucoma, defined as persistently high IOP (> 21 mmHg) despite taking at least 3 IOP-lowering medications subsequent to undergoing a glaucoma drainage device (GDD) with or without a second GDD or cilioablative procedure. Eyes with previous failed GDD underwent subconjunctival 0.3 cc (0.4 mg/ml) mitomycin C, tenonectomy, and placement of an ab- externo XEN stent. The outcome measures included change in IOP and the number of glaucoma medications. Success was defined as patients achieving an IOP ≤ 18 mmHg with a percentage reduction of 25% or 15 mmHg and 40% mean IOP reduction from baseline while taking the same number or fewer medications. Results All six eyes with age of 77.6 ± 7.82 years who underwent XEN implantation following previous GDD surgery had primary open-angle glaucoma. The IOP decreased significantly from 32.33 ± 5.99 to 12.67 ± 3.27 mmHg (p
- Published
- 2024
- Full Text
- View/download PDF