Interobserver reliability of echocardiography for prognostication of normotensive patients with pulmonary embolism.

Authors :
Kopecna, Dita
Briongos, Sem
Castillo, Hugo
Moreno, Carlos
Recio, Mónica
Navas, Paula
Lobo, José Luis
Alonso-Gomez, Angel
Obieta-Fresnedo, Izaskun
Fernández-Golfin, Covadonga
Zamorano, José Luis
Jiménez, David
Source :
Cardiovascular Ultrasound. 2014, Vol. 12 Issue 1, p1-7. 7p. 5 Charts, 3 Graphs.
Publication Year :
2014

Abstract

Objectives: To evaluate the interobserver reliability of echocardiographic findings of right ventricle (RV) dysfunction for prognosticating normotensive patients with pulmonary embolism (PE). Methods: A central panel of cardiologists evaluated echocardiographic studies of 75 patients included in the PROTECT study for the following signs: RV diameter, RV/left ventricular (LV) diameter ratio, hypokinesis of the RV free wall, and tricuspid plane systolic excursion (TAPSE). Investigators used intraclass correlation to assess agreement between the measurements of the central panel and each of the local cardiologists. Investigators used the single weighted kappa statistic to test for agreement between readers of interpretation of RV enlargement and RV hypokinesis. Results: The two observers had fair agreement (к = 0.45) for RV enlargement assessed by the RV diameter, and good agreement (к = 0.65) for RV enlargement assessed by the RV/LV diameter ratio. The interobserver reliability of the assessment whether hypokinesis of the RV free wall is present was good (к = 0.70), and whether RV dysfunction (assessed by TAPSE measurement) is present was very good (к = 0.86). The intraclass correlation for the RV/LV diameter ratio was fair (0.55; 95% confidence interval [CI], 0.37-0.69), for the RV diameter was good (0.70; 95% CI, 0.56-0.80), and for the TAPSE measurement was very good (0.85; 95% CI, 0.77-0.90). On Bland-Altman analysis, the mean differences for RV diameter, RV/LV diameter ratio and TAPSE measurement were 2.33 (±5.38), 0.06 (±0.23) and 0.08 (±2.20), respectively. Conclusion: TAPSE measurement is the least user dependent and most reproducible echocardiographic finding of RV dysfunction in normotensive patients with PE. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
14767120
Volume :
12
Issue :
1
Database :
Academic Search Index
Journal :
Cardiovascular Ultrasound
Publication Type :
Academic Journal
Accession number :
100824033
Full Text :
https://doi.org/10.1186/1476-7120-12-29