Back to Search Start Over

Method for Detecting an Open-Switch Fault in a Grid-Connected NPC Inverter System.

Authors :
Ui-Min Choi
Hae-Gwang Jeong
Kyo-Beum Lee
Blaabjerg, F.
Source :
IEEE Transactions on Power Electronics. Jun2012, Vol. 27 Issue 6, p2726-2739. 14p.
Publication Year :
2012

Abstract

This paper proposes a fault-detection method for an open-switch fault in the switches of grid-connected neutral-point-clamped inverter systems. The proposed method can not only detect the fault condition but also identify the location of the faulty switch. In the proposed method, which is designed by incorporating a simple switching control in the conventional method, the fault condition is detected on the basis of the radius of the Concordia current pattern, and the location of the faulty switch can be identified. By using the proposed method, it is possible to detect the open-switch fault and identify the faulty switch within two fundamental periods, without using additional sensors or performing complex calculations. Simulations and experiments are carried out to confirm the reliability of the proposed fault-detection method. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
08858993
Volume :
27
Issue :
6
Database :
Academic Search Index
Journal :
IEEE Transactions on Power Electronics
Publication Type :
Academic Journal
Accession number :
101264463
Full Text :
https://doi.org/10.1109/TPEL.2011.2178435