A study on an online measurement method to determine the oil discharge ratio by utilizing Coriolis mass flow meter in a calorimeter.
- Source :
-
International Journal of Refrigeration . Apr2015, Vol. 52, p42-50. 9p. - Publication Year :
- 2015
-
Abstract
- In this paper, an online measurement method of oil discharge ratio (ODR) is experimentally investigated based on a compressor calorimeter with the Coriolis mass flowmeter (CMF). In this method, the oil concentration is determined by a linear mixing law of the specific volume model using the density of the refrigerant, oil and refrigerant-oil mixture obtained by CMF. During the testing, the light absorption method is also conducted simultaneously for the comparison. The results indicate that the presented CMF based density method has an average relative deviation of 4.28%. The accuracy of the CMF based density method is superior to the light absorption method, which has the relative deviation of −8∼23% compared with the standard sampling method. The presented CMF-based method can be expected to be used for future ODR measurement due to its non-sampling, online, and accurate features. [ABSTRACT FROM AUTHOR]
- Subjects :
- *CORIOLIS force
*CALORIMETERS
*LIGHT absorption
*STANDARD deviations
*COMPRESSORS
Subjects
Details
- Language :
- English
- ISSN :
- 01407007
- Volume :
- 52
- Database :
- Academic Search Index
- Journal :
- International Journal of Refrigeration
- Publication Type :
- Academic Journal
- Accession number :
- 102317329
- Full Text :
- https://doi.org/10.1016/j.ijrefrig.2014.11.017