Back to Search Start Over

Development of a cost-effective and flexible vibration DAQ system for long-term continuous structural health monitoring.

Authors :
Nguyen, Theanh
Chan, Tommy H.T.
Thambiratnam, David P.
King, Les
Source :
Mechanical Systems & Signal Processing. Dec2015, Vol. 64/65, p313-324. 12p.
Publication Year :
2015

Abstract

In the structural health monitoring (SHM) field, long-term continuous vibration-based monitoring is becoming increasingly popular as this could keep track of the health status of structures during their service lives. However, implementing such a system is not always feasible due to on-going conflicts between budget constraints and the need of sophisticated systems to monitor real-world structures under their demanding in-service conditions. To address this problem, this paper presents a comprehensive development of a cost-effective and flexible vibration DAQ system for long-term continuous SHM of a newly constructed institutional complex with a special focus on the main building. First, selections of sensor type and sensor positions are scrutinized to overcome adversities such as low-frequency and low-level vibration measurements. In order to economically tackle the sparse measurement problem, a cost-optimized Ethernet-based peripheral DAQ model is first adopted to form the system skeleton. A combination of a high-resolution timing coordination method based on the TCP/IP command communication medium and a periodic system resynchronization strategy is then proposed to synchronize data from multiple distributed DAQ units. The results of both experimental evaluations and experimental–numerical verifications show that the proposed DAQ system in general and the data synchronization solution in particular work well and they can provide a promising cost-effective and flexible alternative for use in real-world SHM projects. Finally, the paper demonstrates simple but effective ways to make use of the developed monitoring system for long-term continuous structural health evaluation as well as to use the instrumented building herein as a multi-purpose benchmark structure for studying not only practical SHM problems but also synchronization related issues. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
08883270
Volume :
64/65
Database :
Academic Search Index
Journal :
Mechanical Systems & Signal Processing
Publication Type :
Academic Journal
Accession number :
103136890
Full Text :
https://doi.org/10.1016/j.ymssp.2015.04.003