Back to Search
Start Over
Prototype of Data Acquisition Systems for ITER Divertor Thomson Scattering Diagnostic.
- Source :
-
IEEE Transactions on Nuclear Science . 6/10/2015 Part 2, Vol. 62 Issue 3b, p1181-1186. 6p. - Publication Year :
- 2015
-
Abstract
- The prototype of uniquely designed complex data acquisition system for ITER divertor Thomson scattering diagnostic was developed. It allows recording short duration (3-5 ns) scattered pulses with 2 GHz sampling rate and 10-bit total resolution in oscilloscope mode. The system consists of 48 photo detector modules with 0-200 MHz bandwidth, 48 simultaneously sampling ADC modules and synchronization subsystem. The photo detector modules are based on avalanche photodiodes (APD) and ultra-low noise transimpedance amplifiers. ADC modules include fast analog to digital convertors and digital units based on the FPGA (Field-Programmable Gate Array) for data processing and storage. The synchronization subsystem is used to form triggering pulses and to organize the simultaneously mode of ADC modules operation. [ABSTRACT FROM PUBLISHER]
Details
- Language :
- English
- ISSN :
- 00189499
- Volume :
- 62
- Issue :
- 3b
- Database :
- Academic Search Index
- Journal :
- IEEE Transactions on Nuclear Science
- Publication Type :
- Academic Journal
- Accession number :
- 103264781
- Full Text :
- https://doi.org/10.1109/TNS.2015.2428195