Back to Search Start Over

Enhancement of Lamb Wave Imaging Resolution by Step Pulse Excitation and Prewarping.

Authors :
Fu, Shangchen
Shi, Lihua
Zhou, Yinghui
Fu, Zhikai
Source :
Shock & Vibration. 2/22/2015, Vol. 2015, p1-8. 8p.
Publication Year :
2015

Abstract

For the purpose of improving the damage localization accuracy, a prewarping technology is combined with step pulse excitation and this method is used in Lamb wave imaging of plate structures with adjacent damages. Based on the step pulse excitation, various narrowband or burst response can be derived by signal processing technology and this method provides flexibility for further prewarping approach. A narrowband signal warped with a preselected distance is then designed, and the dispersion in the response of this prewarping signal will be greatly reduced. However, in order to calculate the distance for prewarping, the first arrival needs to be estimated from the burst response. From the step-pulse response, narrowband responses at different central frequencies can be obtained, and by averaging peak-value time of their first arrivals, a more accurate estimation can be calculated. By using the prewarping method to the damage scattering signals before imaging, the imaging resolution of the delay-and-sum method can be highly enhanced. The experiment carried out in an aluminum plate with adjacent damages proves the efficiency of this method. [ABSTRACT FROM AUTHOR]