Back to Search Start Over

Different remodelling against left ventricular overload between diabetic and non-diabetic haemodialysis patients.

Authors :
Nishimura, Masato
Hashimoto, Tetsuya
Kobayashi, Hiroyuki
Fukukda, Toyofumi
Okino, Koji
Yamamoto, Noriyuki
Nakamura, Naoto
Yoshikawa, Toshikazu
Takahashi, Hakuo
Ono, Toshihiko
Source :
Clinical & Experimental Pharmacology & Physiology. Oct2003, Vol. 30 Issue 10, p786. 7p.
Publication Year :
2003

Abstract

Summary 1. Diabetes mellitus is significantly associated with the occurrence of congestive heart failure in end-stage renal disease patients undergoing maintenance haemodialysis. In the present study, we asked whether the left ventricular remodelling against sustained pressure and/or volume overload to the left ventricle may be different between diabetic and non-diabetic haemodialysis patients. 2. Left ventricular parameters, including left ventricular mass index (LVMI), interventricular septal wall thickness (IVST) and relative left ventricular wall thickness (rLVWT), were assessed in 486 patients receiving maintenance haemodialysis (145 diabetic and 341 non-diabetic patients) using transthoracic echocardiography. Plasma concentrations of B-type natriuretic peptide (BNP), measured with an immunoradiometric assay, were used as a humoral parameter indicating left ventricular wall stress. 3. In non-diabetic patients, the plasma BNP concentration correlated with LVMI (r = 0.245; P = 0.0001), IVST (r = 0.250; P = 0.0001) and rLVWT (r = 0.149; P = 0.006). Furthermore, LVMI was correlated with mean blood pressure and pulse pressure and IVST and rLVWT were correlated with pulse pressure. 4. In contrast, none of the measured factors was correlated with LVMI and IVST in diabetic patients. Plasma BNP concentrations were positively correlated with end-systolic and end-diastolic left intraventricular dimensions and were inversely correlated with rLVWT and left ventricular fractional shortening in diabetic patients, but not in non-diabetic patients. 5. In conclusion, a sustained increase in left ventricular wall stress is likely to elicit eccentric left ventricular remodelling in diabetic haemodialysis patients, whereas it causes concentric left ventricular remodelling in non-diabetic haemodialysis patients. This difference in left ventricular remodelling against left ventricular overload may be associated with the high incidence of congestive heart failure in diabetic haemodialysis patients. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
03051870
Volume :
30
Issue :
10
Database :
Academic Search Index
Journal :
Clinical & Experimental Pharmacology & Physiology
Publication Type :
Academic Journal
Accession number :
10937200
Full Text :
https://doi.org/10.1046/j.1440-1681.2003.03914.x