Low-complexity leakage current acquisition system for transmission line insulators employing GSM voice channel.
- Source :
-
Electronics Letters (Wiley-Blackwell) . 9/17/2015, Vol. 51 Issue 19, p1538-1539. 2p. 3 Diagrams, 2 Graphs. - Publication Year :
- 2015
-
Abstract
- With the rapid advancements in electronics and in communication infrastructures, the deployment of low-complexity devices for power system monitoring has become an active area of research. For the large-scale deployment of monitoring devices, robust and economical remote data acquisition systems for power system monitoring are required. Keeping this in mind, the scheme of a remote leakage current acquisition system for high-voltage insulators that may be employed for remote monitoring purposes is described. A low-complexity method is adopted for the extraction of harmonic information from the leakage current signal. Unlike existing remote insulator-monitoring techniques that employ a dedicated fibre-optic network and satellite communication, the mobile communication voice channel is used to communicate the data to a central location for analysis. This provides an economical solution for the remote monitoring of insulators that may be used for large-scale deployment. [ABSTRACT FROM AUTHOR]
Details
- Language :
- English
- ISSN :
- 00135194
- Volume :
- 51
- Issue :
- 19
- Database :
- Academic Search Index
- Journal :
- Electronics Letters (Wiley-Blackwell)
- Publication Type :
- Academic Journal
- Accession number :
- 109513702
- Full Text :
- https://doi.org/10.1049/el.2015.1747