- This paper suggests a cascade output voltage regulation strategy for dc/dc boost converters that embeds a robust inner-loop current controller against parameter variations. The contributions of this paper are divided into two parts. The first contribution is to present a simple and robust inner-loop current controller despite parameter uncertainties, guaranteeing the stability of the whole closed-loop system including the first-order internal dynamics. The second contribution is to show that an outer-loop proportional–integral regulator can stabilize the output voltage error without relying on any parameter information. Simulations and experiments using a 3-kW dc/dc boost converter showed that the proposed method offers satisfactory closed-loop performance in the presence of parameter uncertainties. [ABSTRACT FROM PUBLISHER]
Details
- Language :
- English
- ISSN :
- 02780046
- Volume :
- 62
- Issue :
- 11
- Database :
- Academic Search Index
- Journal :
- IEEE Transactions on Industrial Electronics
- Publication Type :
- Academic Journal
- Accession number :
- 110255896
- Full Text :
- https://doi.org/10.1109/TIE.2015.2443102