Back to Search
Start Over
Unsteady non-Newtonian blood flow through a tapered overlapping stenosed catheterized vessel.
- Source :
-
Mathematical Biosciences . Nov2015, Vol. 269, p94-103. 10p. - Publication Year :
- 2015
-
Abstract
- The unsteady flow characteristics of blood in a catheterized overlapping stenosed artery are analyzed in presence of body acceleration and magnetic field. The stenosed arterial segment is modeled as a rigid constricted tube. An improved shape of stenosis in the realm of the formulation of the arterial narrowing caused by atheroma is integrated in the present study. The catheter inside the artery is approximated by a thin rigid tube of small radius while the streaming blood in the artery is characterized by the Carreau model. Employing mild stenosis condition, the governing equation of the flow is derived which is then solving numerically using finite difference scheme. The variation of axial velocity, flow rate, resistance impendence and wall shear stress is shown graphically for various parameters of interest. The flow patterns illustrating the global behavior of blood are also presented. [ABSTRACT FROM AUTHOR]
Details
- Language :
- English
- ISSN :
- 00255564
- Volume :
- 269
- Database :
- Academic Search Index
- Journal :
- Mathematical Biosciences
- Publication Type :
- Periodical
- Accession number :
- 110325263
- Full Text :
- https://doi.org/10.1016/j.mbs.2015.08.018