Modified DC-Bus Voltage Balancing Algorithm for a Three-Level Neutral-Point-Clamped PMSM Inverter Drive With Reduced Common-Mode Voltage.
- Source :
-
IEEE Transactions on Industry Applications . Jan2016, Vol. 52 Issue 1, p278-292. 15p. - Publication Year :
- 2016
-
Abstract
- This paper presents an improved dc-link voltage balancing algorithm for a three-level neutral-point-clamped inverter by considering phase current direction. Detailed studies on the effects of change in load current direction on the dc-link capacitor voltages are presented. A maximum value of power factor is numerically derived, above which it affects the capacitor voltage balancing capability. Compared with the previously presented research work, the inputs to the space-vector pulsewidth-modulation block are the three phase currents and the difference between the two capacitor voltages. Depending on the states of the two dc-link capacitor voltages and phase current direction, redundant voltage vector sequences are selected. The selected vectors keep the capacitor voltage deviations within 5% of the total dc-link voltage. Two zero switching vectors (i.e., PPP and NNN) are also removed from all subsectors of the earlier proposed strategy, which one used to produce higher common-mode voltages. Detailed simulation and experimental results are presented in this paper for a 6.0-kW surface permanent-magnet synchronous machine. Both the simulation and experimental results show the required performance of the proposed system. [ABSTRACT FROM AUTHOR]
Details
- Language :
- English
- ISSN :
- 00939994
- Volume :
- 52
- Issue :
- 1
- Database :
- Academic Search Index
- Journal :
- IEEE Transactions on Industry Applications
- Publication Type :
- Academic Journal
- Accession number :
- 112441551
- Full Text :
- https://doi.org/10.1109/TIA.2015.2474307