Back to Search Start Over

Detection of alloantibody-mediated complement activation: A diagnostic advance in monitoring kidney transplant rejection?

Authors :
Böhmig, Georg A.
Kikic, Zeljko
Wahrmann, Markus
Eskandary, Farsad
Aliabadi, Arezu Z.
Zlabinger, Gerhard J.
Regele, Heinz
Feucht, Helmut E.
Source :
Clinical Biochemistry. Mar2016, Vol. 49 Issue 4/5, p394-403. 10p.
Publication Year :
2016

Abstract

Objective Antibody-mediated rejection (ABMR) is an important cause of kidney allograft injury. In the last two decades, detection of complement split product C4d along transplant capillaries, a footprint of antibody-mediated classical complement activation, has evolved as a useful diagnostic marker of ABMR. While it was recognized that ABMR may occur also in the absence of C4d, numerous studies have shown that C4d deposition may indicate a more severe rejection phenotype associated with poor graft survival. Such studies suggest a possible diagnostic benefit of ex vivo monitoring the complement-activating capability of circulating alloantibodies. Design and methods We reviewed the literature between 1993 and 2015, focusing on in vivo (biopsy work-up) and in vitro detection (modified bead array technology) of HLA antibody-triggered classical complement activation in kidney transplantation. Results Precise HLA antibody detection methods, in particular Luminex-based single antigen bead (SAB) assays, have provided a valuable basis for the design of techniques for in vitro detection of HLA antibody-triggered complement activation reflected by C1q, C4 or C3 split product deposition to the bead surface. Establishing such assays it was recognized that deposition of complement products to SAB, which critically depends on antibody binding strength, may be a cardinal trigger of the prozone effect, a troublesome in vitro artifact caused by a steric interference with IgG detection reagents. False-low IgG results, especially on SAB with extensive antibody binding, have to be considered when interpreting studies analyzing the diagnostic value of complement in relation to standard IgG detection. Levels of complement-fixing donor-specific antibodies (DSA) were shown to correlate with the results of standard crossmatch tests, suggesting potential application for crossmatch prediction. Moreover, while the utility of pre-transplant complement detection, at least in crossmatch-negative transplant recipients, is controversially discussed, a series of studies have shown that the appearance of post-transplant complement-fixing DSA may be associated with C4d deposition in transplant capillaries and a particular risk of graft failure. Conclusions The independent value of modified single antigen bead assays, as compared to a careful analysis of standard IgG detection, which may be affected considerably by complement dependent artifacts, needs to be clarified. Whether they have the potential to improve the predictive accuracy of our current diagnostic repertoire warrants further study. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
00099120
Volume :
49
Issue :
4/5
Database :
Academic Search Index
Journal :
Clinical Biochemistry
Publication Type :
Academic Journal
Accession number :
113478315
Full Text :
https://doi.org/10.1016/j.clinbiochem.2015.05.024