Back to Search Start Over

Exploring the mechanisms underpinning sweating: the development of a specialized ventilated capsule for use with intradermal microdialysis.

Authors :
Meade, Robert D.
Louie, Jeffrey C.
Poirier, Martin P.
McGinn, Ryan
Fujii, Naoto
Kenny, Glen P.
Source :
Physiological Reports. Mar2016, Vol. 4 Issue 6, pn/a-N.PAG. 11p.
Publication Year :
2016

Abstract

Many studies have aimed to identify the controllers of sweating using ventilated capsules with intradermal microdialysis. It is unclear, however, if the surface area covered by the capsule influences the observed response as a result of differences in the number of sweat glands affected by the infused pharmacological agent relative to the total glands captured by the capsule. We evaluated the area of skin perfused with agents delivered via microdialysis. Thereafter, we developed a specialized sweat capsule (1.1 cm2) and compared the sweating response with a classic capsule (2.8 cm2). In Protocol 1 ( n = 6), methacholine was delivered to forearm skin in a dose-dependent manner (1-2000 mmol L−1). The area of activated sweat glands was assessed via the modified iodine-paper technique. In Protocol 2 ( n = 6), the area of inhibited sweat glands induced by ouabain and atropine was assessed during moderate-intensity cycling. Marked variability in the affected skin area was observed (0.9 ± 0.4 to 5.2 ± 1.1 cm2). In Protocol 3 ( n = 6), we compared the attenuation in local sweat rate ( LSR) induced by atropine between the new and classic capsule during moderate-intensity cycling. Atropine attenuated sweating as assessed using the new (control: 0.87 ± 0.23 mg min−1 cm−2 vs. atropine: 0.54 ± 0.22 mg min−1 cm−2; P < 0.01) and classic (control: 0.85 ± 0.33 mg min−1 cm−2 vs. atropine: 0.60 ± 0.26 mg min−1 cm−2; P = 0.05) capsule designs. Importantly, responses did not differ between capsule designs ( P = 0.23). These findings provide critical information regarding the skin surface area perfused by microdialysis and suggest that use of a larger capsule does not alter the mechanistic insight into the sweating response gained when using microdialysis. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
2051817X
Volume :
4
Issue :
6
Database :
Academic Search Index
Journal :
Physiological Reports
Publication Type :
Academic Journal
Accession number :
114119884
Full Text :
https://doi.org/10.14814/phy2.12738