Back to Search Start Over

Validation of selected analytical methods using accuracy profiles to assess the impact of a Tobacco Heating System on indoor air quality.

Authors :
Mottier, Nicolas
Tharin, Manuel
Cluse, Camille
Crudo, Jean-René
Lueso, María Gómez
Goujon-Ginglinger, Catherine G.
Jaquier, Anne
Mitova, Maya I.
Rouget, Emmanuel G.R.
Schaller, Mathieu
Solioz, Jennifer
Source :
Talanta. Sep2016, Vol. 158, p165-178. 14p.
Publication Year :
2016

Abstract

Studies in environmentally controlled rooms have been used over the years to assess the impact of environmental tobacco smoke on indoor air quality. As new tobacco products are developed, it is important to determine their impact on air quality when used indoors. Before such an assessment can take place it is essential that the analytical methods used to assess indoor air quality are validated and shown to be fit for their intended purpose. Consequently, for this assessment, an environmentally controlled room was built and seven analytical methods, representing eighteen analytes, were validated. The validations were carried out with smoking machines using a matrix-based approach applying the accuracy profile procedure. The performances of the methods were compared for all three matrices under investigation: background air samples, the environmental aerosol of Tobacco Heating System THS 2.2, a heat-not-burn tobacco product developed by Philip Morris International, and the environmental tobacco smoke of a cigarette. The environmental aerosol generated by the THS 2.2 device did not have any appreciable impact on the performances of the methods. The comparison between the background and THS 2.2 environmental aerosol samples generated by smoking machines showed that only five compounds were higher when THS 2.2 was used in the environmentally controlled room. Regarding environmental tobacco smoke from cigarettes, the yields of all analytes were clearly above those obtained with the other two air sample types. Graphical abstractfx1Highlights· Selected indoor air quality methods were validated using accuracy profiles. · The impact of a novel Tobacco Heating System on these methods was assessed. · Environmental tobacco smoke and background air samples were also validated. · The methods were apt for the detection and quantification of 18 constituents in air. · Methods were applied for evaluating the impact of tobacco products on indoor air. Abbreviations [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
00399140
Volume :
158
Database :
Academic Search Index
Journal :
Talanta
Publication Type :
Academic Journal
Accession number :
116374003
Full Text :
https://doi.org/10.1016/j.talanta.2016.05.022