Near-field transport by a bent multi-wire endoscope.
- Source :
-
Journal of Applied Physics . 8/14/2016, Vol. 120 Issue 6, p1-13. 13p. 2 Diagrams, 10 Graphs. - Publication Year :
- 2016
-
Abstract
- In this paper, we investigate the impact of bending a multi-wire endoscope in the context of subwavelength imaging and near-field transport. To this end, we study the reflection and transmission by a "bent" wire medium in different configurations and demonstrate that the structure can be quite robust to the effect of bending provided the total length of the bent wires satisfies the Fabry-Pérot condition. The study is carried out relying on an analytical homogenization theory and using two additional boundary conditions obtained with physical arguments. It is proven that a structure formed by two connected sets of tilted metallic wires can allow for the near field transport with a deeply subwavelength resolution. To illustrate the applications and potentials of the results, the performance of bent multi-wire endoscopes is characterized using full wave numerical simulations. [ABSTRACT FROM AUTHOR]
Details
- Language :
- English
- ISSN :
- 00218979
- Volume :
- 120
- Issue :
- 6
- Database :
- Academic Search Index
- Journal :
- Journal of Applied Physics
- Publication Type :
- Academic Journal
- Accession number :
- 117407908
- Full Text :
- https://doi.org/10.1063/1.4960346