Back to Search Start Over

gr-MRI: A software package for magnetic resonance imaging using software defined radios.

Authors :
Hasselwander, Christopher J.
Cao, Zhipeng
Grissom, William A.
Source :
Journal of Magnetic Resonance. Sep2016, Vol. 270, p47-55. 9p.
Publication Year :
2016

Abstract

The goal of this work is to develop software that enables the rapid implementation of custom MRI spectrometers using commercially-available software defined radios (SDRs). The developed gr-MRI software package comprises a set of Python scripts, flowgraphs, and signal generation and recording blocks for GNU Radio, an open-source SDR software package that is widely used in communications research. gr-MRI implements basic event sequencing functionality, and tools for system calibrations, multi-radio synchronization, and MR signal processing and image reconstruction. It includes four pulse sequences: a single-pulse sequence to record free induction signals, a gradient-recalled echo imaging sequence, a spin echo imaging sequence, and an inversion recovery spin echo imaging sequence. The sequences were used to perform phantom imaging scans with a 0.5 Tesla tabletop MRI scanner and two commercially-available SDRs. One SDR was used for RF excitation and reception, and the other for gradient pulse generation. The total SDR hardware cost was approximately $2000. The frequency of radio desynchronization events and the frequency with which the software recovered from those events was also measured, and the SDR’s ability to generate frequency-swept RF waveforms was validated and compared to the scanner’s commercial spectrometer. The spin echo images geometrically matched those acquired using the commercial spectrometer, with no unexpected distortions. Desynchronization events were more likely to occur at the very beginning of an imaging scan, but were nearly eliminated if the user invoked the sequence for a short period before beginning data recording. The SDR produced a 500 kHz bandwidth frequency-swept pulse with high fidelity, while the commercial spectrometer produced a waveform with large frequency spike errors. In conclusion, the developed gr-MRI software can be used to develop high-fidelity, low-cost custom MRI spectrometers using commercially-available SDRs. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
10907807
Volume :
270
Database :
Academic Search Index
Journal :
Journal of Magnetic Resonance
Publication Type :
Academic Journal
Accession number :
117586578
Full Text :
https://doi.org/10.1016/j.jmr.2016.06.023