Back to Search Start Over

Progress in the Design and Testing of In-Vessel Magnetic Pickup Coils for ITER.

Authors :
Peruzzo, S.
Brombin, M.
Furno Palumbo, M.
Gonzalez, W.
Marconato, N.
Rizzolo, A.
Arshad, S.
Ma, Y.
Vayakis, G.
Suarez, A.
Duran, I.
Viererbl, L.
Lahodova, Z.
Source :
IEEE Transactions on Plasma Science. Sep2016 Part 1, Vol. 44 Issue 9, Part1, p1704-1710. 7p.
Publication Year :
2016

Abstract

This paper presents the results of the R&D activities recently performed to achieve the preliminary design of electromagnetic transducers for in-vessel local magnetic field measurements at low frequency (<30 kHz) for ITER. The study is based on thermoelectrical and electromagnetic bench tests performed on a batch of 40 sensor prototypes manufactured with the low temperature cofired ceramic (LTCC) technology. Also, the outcomes of a first neutron irradiation test on LTCC sensors are presented. The development of an alternative concept of a magnetic sensor for ITER, based on mineral insulated cables winding is also reported, with suitable thermomechanical and electromagnetic numerical analyses performed to assess the reliability of such sensors within the ITER operating conditions. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
00933813
Volume :
44
Issue :
9, Part1
Database :
Academic Search Index
Journal :
IEEE Transactions on Plasma Science
Publication Type :
Academic Journal
Accession number :
118051804
Full Text :
https://doi.org/10.1109/TPS.2016.2580380