Back to Search
Start Over
Rhythm Control and Its Relation to Symptoms during the First Two Years after Radiofrequency Ablation for Atrial Fibrillation.
- Source :
-
Pacing & Clinical Electrophysiology . Sep2016, Vol. 39 Issue 9, p914-925. 12p. - Publication Year :
- 2016
-
Abstract
- Clinical Trial Registration URL: . Unique Identifier: NCT00697359. Objectives To evaluate rhythm control up to two years after atrial fibrillation (AF) ablation and its relation to reported symptoms. Background The implantable loop recorder (ILR) continuously records the electrocardiogram (ECG), has an automatic AF detection algorithm, and has a possibility for patients to activate an ECG recording during symptoms. Methods Fifty-seven patients (mean age 57 ± 9 years, 60% male, 88% paroxysmal AF) underwent AF ablation following ILR implantation. Device data were downloaded at the ablation and three, six, 12, 18, and 24 months after ablation. Results Fifty-four patients completed the two-year follow-up. Thirteen (24%) patients had no AF episodes detected by ILR during follow-up. Ten of 41 patients (24%) with AF recurrence were only detected by ILR and AF recurrences were detected earlier by ILR (P < 0.001). The median AF burden in patients with AF recurrence was 5.7% (interquartile range 0.4-14.4) and was even lower in patients with AF only detected by ILR (P = 0.001). Forty-eight % of the patients indicated symptoms via the patient activator but 33% of those recordings were not due to AF. Early AF recurrence (within 3 months) was highly associated with later AF recurrence (P < 0.001). AF burden >0.5% and longest AF episode >6 hours before the ablation were independent predictors of AF recurrence during intermittent but not continuous monitoring. Conclusions After AF ablation, the AF burden was low throughout the 24 months follow-up. Nevertheless, symptoms were commonly indicated but one-third of patient-activated recordings did not show AF. Continuous monitoring was superior to intermittent follow-up in detecting AF episodes and assessing the AF burden. [ABSTRACT FROM AUTHOR]
- Subjects :
- *ATRIAL fibrillation treatment
*ARRHYTHMIA
*ATRIAL fibrillation
*CATHETER ablation
*CONFIDENCE intervals
*ELECTROCARDIOGRAPHY
*HEART beat
*IMPLANTABLE cardioverter-defibrillators
*LONGITUDINAL method
*PATIENT monitoring
*PROBABILITY theory
*RESEARCH funding
*T-test (Statistics)
*MATHEMATICAL variables
*DISEASE relapse
*LOGISTIC regression analysis
*PRODUCT design
*DATA analysis
*MULTIPLE regression analysis
*BODY mass index
*PROPORTIONAL hazards models
*DATA analysis software
*DESCRIPTIVE statistics
*KAPLAN-Meier estimator
*MANN Whitney U Test
*FRIEDMAN test (Statistics)
*SYMPTOMS
Subjects
Details
- Language :
- English
- ISSN :
- 01478389
- Volume :
- 39
- Issue :
- 9
- Database :
- Academic Search Index
- Journal :
- Pacing & Clinical Electrophysiology
- Publication Type :
- Academic Journal
- Accession number :
- 118092725
- Full Text :
- https://doi.org/10.1111/pace.12916