H8 Inverter for Common-Mode Voltage Reduction in Electric Drives.

Authors :
Concari, Luca
Barater, Davide
Buticchi, Giampaolo
Concari, Carlo
Liserre, Marco
Source :
IEEE Transactions on Industry Applications. Sep2016, Vol. 52 Issue 5, p4010-4019. 10p.
Publication Year :
2016

Abstract

This paper presents a modified two-level three-phase inverter for the reduction of the leakage current. With respect to a traditional two-level inverter, the proposed solution reduces the common-mode voltage (CMV), both in amplitude and frequency. Between the dc source and the traditional three-phase bridge, two active dc-decoupling devices and a voltage-clamping network have been added. A dedicated control strategy was developed adopting a modified space vector pulse-width modulation, oriented to the reduction of the CMV. Simulations showing the good performance of the solution are presented. A preliminary prototype was developed and experimental results are presented. [ABSTRACT FROM PUBLISHER]

Details

Language :
English
ISSN :
00939994
Volume :
52
Issue :
5
Database :
Academic Search Index
Journal :
IEEE Transactions on Industry Applications
Publication Type :
Academic Journal
Accession number :
118249253
Full Text :
https://doi.org/10.1109/TIA.2016.2581763