Improved Φ-OTDR system with narrow pulses for quantitative strain measurement based on ultra-weak fiber bragg grating array.
- Source :
-
Microwave & Optical Technology Letters . Dec2016, Vol. 58 Issue 12, p2892-2894. 3p. 1 Diagram, 2 Graphs. - Publication Year :
- 2016
-
Abstract
- ABSTRACT We proposed an improved Φ-OTDR system based on ultra-weak fiber Bragg grating arrays to realize quantitative strain measurement using narrow pulse, which can extend the detectable fiber length. Experimental results showed that quantitative strain measurement at the end of a 4km long sensing fiber could be realized with 50ns pulses. © 2016 Wiley Periodicals, Inc. Microwave Opt Technol Lett 58:2892-2894, 2016 [ABSTRACT FROM AUTHOR]
Details
- Language :
- English
- ISSN :
- 08952477
- Volume :
- 58
- Issue :
- 12
- Database :
- Academic Search Index
- Journal :
- Microwave & Optical Technology Letters
- Publication Type :
- Academic Journal
- Accession number :
- 118280795
- Full Text :
- https://doi.org/10.1002/mop.30178