Effects of Electrostatic Discharges on Bearing Grease Dielectric Strength and Composition.

Authors :
Romanenko, Aleksei
Muetze, Annette
Ahola, Jero
Source :
IEEE Transactions on Industry Applications. Nov2016, Vol. 52 Issue 6, p4835-4842. 8p.
Publication Year :
2016

Abstract

Bearing faults may significantly reduce the useful life of electric machines. With the advent of modern fast-switching frequency converters, electric currents induced by the high-frequency common-mode voltage of these converters have been recognized as additional, sometimes severe, contributors to bearing degradation. The degradation is understood to progress both by damaging the bearing surfaces and by altering the chemical composition of the lubrication greases, which can lead to ineffective lubrication and reduction in permissible mechanical bearing load. This paper studies the effect of grease degradation due to discharge currents on the grease dielectric strength and chemical composition of several greases typically used with electric drives. From this, conclusions on the grease selection for variable-speed drive applications are drawn. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
00939994
Volume :
52
Issue :
6
Database :
Academic Search Index
Journal :
IEEE Transactions on Industry Applications
Publication Type :
Academic Journal
Accession number :
119616437
Full Text :
https://doi.org/10.1109/TIA.2016.2596239