Back to Search Start Over

3D numerical thermal optimization of the roofs constructed with cast-in-situ hollow concrete floor system by finite volume method.

Authors :
Shi, G.Z.
Li, L.P.
Song, C.F.
Cheng, S.M.
Tao, W.Q.
He, Y.L.
Source :
Energy & Buildings. Nov2016, Vol. 131, p142-152. 11p.
Publication Year :
2016

Abstract

3D numerical thermal simulation on conjugate heat transfer in hollow roofs is conducted by self-compiled program based on the finite volume method to improve insulation performance. Eight kinds of hollow roofs with different box fillers are optimized by regularly designing partitions to divide air-filled cavity. In addition, the effect of box filler materials on thermal behavior is considered. The numerical results demonstrate that: horizontal partitions decrease the equivalent thermal conductivity by 13.65%–40.42%, whose effect is more remarkable for higher void roofs, whereas vertical partitions cause few effects. Besides, different box filler materials can bring about slight variation no more than 3%. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
03787788
Volume :
131
Database :
Academic Search Index
Journal :
Energy & Buildings
Publication Type :
Academic Journal
Accession number :
119774651
Full Text :
https://doi.org/10.1016/j.enbuild.2016.09.018