Back to Search Start Over

HotBalloon Ablation of the Pulmonary Veins for Paroxysmal AF: A Multicenter Randomized Trial in Japan.

Authors :
Sohara, Hiroshi
Ohe, Tohru
Okumura, Ken
Naito, Shigeto
Hirao, Kenzo
Shoda, Morio
Kobayashi, Youichi
Yamauchi, Yasuteru
Yamaguchi, Yoshio
Kuwahara, Taishi
Hirayama, Haruo
YeongHwa, Chun
Kusano, Kengo
Kaitani, Kazuaki
Banba, Kimikazu
Fujii, Satoki
Kumagai, Koichiro
Yoshida, Hisashi
Matsushita, Masashi
Satake, Shutaro
Source :
Journal of the American College of Cardiology (JACC). Dec2016, Vol. 68 Issue 25, p2747-2757. 11p.
Publication Year :
2016

Abstract

<bold>Background: </bold>Point-by-point catheter ablation is an established treatment for drug-refractory paroxysmal atrial fibrillation (PAF). However, it is time consuming, requires excellent technique to achieve complete pulmonary vein (PV) isolation, and is associated with severe complications.<bold>Objectives: </bold>The purpose of this study was to evaluate the safety and effectiveness of a HotBalloon ablation (HBA) compared with antiarrhythmic drug therapy (ADT) for the treatment of PAF.<bold>Methods: </bold>A prospective multicenter randomized controlled study was conducted in Japan. Patients with symptomatic PAF refractory to antiarrhythmic drugs (Class I to IV) were randomized to HBA or ADT at a 2:1 ratio and assessed for effectiveness in a comparable 9-month follow-up period.<bold>Results: </bold>A total of 100 patients in the HBA group and 43 patients in the ADT group received treatment at 17 sites. HBA procedure produced acute complete PV isolation in 98.0% (392 of 400) of the PVs and in 93.0% (93 of 100) of patients in the HBA group. The chronic success rates after the 9-month effective evaluation period were 59.0% in the HBA group (n = 100) and 4.7% in the ADT group (n = 43; p < 0.001). The incidence of major complications was 11.2% (15 of 134 patients). The incidences of PV stenosis (>70%) and transient phrenic nerve injury were 5.2% and 3.7%, respectively. The mean fluoroscopy time was 49.4 ± 26.6 min (n = 134), and the mean procedure duration was 113.9 ± 31.9 min (n = 133).<bold>Conclusions: </bold>This study demonstrates the superiority of HBA compared with ADT for treatment of patients with PAF, and a favorable safety profile. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
07351097
Volume :
68
Issue :
25
Database :
Academic Search Index
Journal :
Journal of the American College of Cardiology (JACC)
Publication Type :
Academic Journal
Accession number :
120141409
Full Text :
https://doi.org/10.1016/j.jacc.2016.10.037