PIC simulations of conical magnetically insulated transmission line with LTD generator: Transition from self-limited to load-limited flow.

Authors :
Laqun Liu
Huihui Wang
Fan Guo
Wenkang Zou
Dagang Liu
Source :
Physics of Plasmas. 2017, Vol. 24 Issue 4, p1-7. 7p. 3 Diagrams, 20 Graphs.
Publication Year :
2017

Abstract

Based on the 3-dimensional Particle-In-Cell (PIC) code CHIPIC3D, with a new circuit boundary algorithm we developed, a conical magnetically insulated transmission line (MITL) with a 1.0-MV linear transformer driver (LTD) is explored numerically. The values of switch jitter time of LTD are critical parameters for the system, which are difficult to be measured experimentally. In this paper, these values are obtained by comparing the PIC results with experimental data of large diode-gap MITL. By decreasing the diode gap, we find that all PIC results agree well with experimental data only if MITL works on self-limited flow no matter how large the diode gap is. However, when the diode gap decreases to a threshold, the self-limited flow would transfer to a load-limited flow. In this situation, PIC results no longer agree with experimental data anymore due to the anode plasma expansion in the diode load. This disagreement is used to estimate the plasma expansion speed. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
1070664X
Volume :
24
Issue :
4
Database :
Academic Search Index
Journal :
Physics of Plasmas
Publication Type :
Academic Journal
Accession number :
122825184
Full Text :
https://doi.org/10.1063/1.4980003