Back to Search
Start Over
Study on failure of an ecological tunnel gate caused by jet-flow from air vents.
- Source :
-
Engineering Failure Analysis . Sep2017, Vol. 79, p1043-1057. 15p. - Publication Year :
- 2017
-
Abstract
- This paper presents analysis of water jet flow state in an ecological tunnel in an abnormal condition and failure analysis of a temporary blocking gate of the ecological tunnel. Analysis consists of the determination of the hydrodynamic pressure on the gate by using experimental test and computational fluid dynamics, the calculation of stress distribution under different operating conditions using finite element method, and a simplified fatigue analysis. Results show that the water jet flow induces a vortex downstream the blocking gate, and under the large displacement and large dynamic stress the damage of gate begins with the local material failure and spreads to total damage with sandwich panel. [ABSTRACT FROM AUTHOR]
Details
- Language :
- English
- ISSN :
- 13506307
- Volume :
- 79
- Database :
- Academic Search Index
- Journal :
- Engineering Failure Analysis
- Publication Type :
- Academic Journal
- Accession number :
- 123917101
- Full Text :
- https://doi.org/10.1016/j.engfailanal.2017.05.013